Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Fluidic hydrogen detector production prototype development

A hydrogen gas sensor that can replace catalytic combustion sensors used to detect leaks in the liquid hydrogen transfer systems at Kennedy Space Center was developed. A fluidic sensor concept, based on the principle that the frequency of a fluidic oscillator is proportional to the square root of the molecular weight of its operating fluid, was utilized. To minimize sensitivity to pressure and temperature fluctuations, and to make the sensor specific for hydrogen, two oscillators are used. One oscillator operates on sample gas containing hydrogen, while the other operates on sample gas with the hydrogen converted to steam. The conversion is accomplished with a small catalytic converter. The frequency difference is taken, and the hydrogen concentration computed with a simple digital processing circuit. The output from the sensor is an analog signal proportional to hydrogen content. The sensor is shown to be accurate and insensitive to severe environmental disturbances. It is also specific for hydrogen, even with large helium concentrations in the sample gas.

Roe, G. W.↗

CAVE3: A general transient heat transfer computer code utilizing eigenvectors and eigenvalues

The method of solution is a hybrid analytical numerical technique which utilizes eigenvalues and eigenvectors. The method is inherently stable, permitting large time steps even with the best of conductors with the finest of mesh sizes which can provide a factor of five reduction in machine time compared to conventional explicit finite difference methods when structures with small time constants are analyzed over long time periods. This code will find utility in analyzing hypersonic missile and aircraft structures which fall naturally into this class. The code is a completely general one in that problems involving any geometry, boundary conditions and materials can be analyzed. This is made possible by requiring the user to establish the thermal network conductances between nodes. Dynamic storage allocation is used to minimize core storage requirements. This report is primarily a user's manual for CAVE3 code. Input and output formats are presented and explained. Sample problems are included which illustrate the usage of the code as well as establish the validity and accuracy of the method.

Palmieri, J. V.↗

Asymmetries in the location of the Venus ionopause

Four large data sets of Venus ionopause observations, based on different definitions and observations by Pioneer Venus Orbiter field and particle instruments, are compared. Regardless of the definition chosen, the ionopause is observed to be higher on average at dawn than at dusk. The results of an empirical ionosphere model and a data analysis technique which minimizes orbital bias are combined to show that most or all of this asymmetry results from the effects of orbital bias and uneven sampling of solar wind conditions. However, an additional asymmetry is found in which the ionopause is displaced in the direction opposite to the motional electric field of the solar wind. This effect is attributed to asymmetric pickup of exospheric ions by the electric and magnetic fields in the magnetosheath. This ion pickup interpretation can be understood in terms of a previous observed magnetosheath magnetic field asymmetry. Quantitative analysis indicates that the transverse momentum imparted by the solar plasma to pickup particles in their initial gyration is transmitted by the magnetosheath magnetic field to the ionosphere boundary.

Phillips, J. L.↗

A Compact Two-Step Laser Time-Of-Flight Mass Spectrometer for In Situ Analysis of Planetary Surfaces

Two-step laser mass spectrometry (L2MS) has proved to be a powerful tool for the analysis of aromatic organics in icy planetary simulants, meteorites, asphaltenes on Earth, and returned cometary particles from the Stardust mission. L2MS employs two lasers to separate the desorption and ionization processes of laser desorption ionization into distinct steps. In the first step, an infrared laser desorbs neutrals from a solid sample surface; in the second step, an ultraviolet laser forms molecular ions within the neutral plume through a resonance-enhanced process to minimize fragment at ion of complex species. We have recently demonstrated that the L2MS technique is compatible with a compact TOF-MS that could form the center piece of a future in situ landed planetary mission emphasizing surface chemistry or astrobiology. The increased sensitivity and selectivity offered by this technique has been demonstrated in analyses of various planetary analog mixtures and meteorite powders, and representative results of these analyses will be presented.

Getty, Stephanie A.↗

Methods and devices configured to operated scanning tunneling microscopes using out-of-bandwidth frequency components added to bias voltage and related software

In the system and method disclosed, an ultrahigh vacuum (UHV) scanning tunneling microscope (STM) tip is used to selectively desorb hydrogen atoms from the Si(100)-2X1:H surface by injecting electrons at a negative sample bias voltage. A new lithography method is disclosed that allows the STM to operate under imaging conditions and simultaneously desorb H atoms as required. A high frequency signal is added to the negative sample bias voltage to deliver the required energy for hydrogen removal. The resulted current at this frequency and its harmonics are filtered to minimize their effect on the operation of the STM's feedback loop. This approach offers a significant potential for controlled and precise removal of hydrogen atoms from a hydrogen-terminated silicon surface and thus may be used for the fabrication of practical silicon-based atomic-scale devices.

Moheimani, Seyed Omid Reza↗

Methods and devices configured to operated scanning tunneling microscopes using out-of-bandwidth frequency components added to bias voltage and related software

In the system and method disclosed, an ultrahigh vacuum (UHV) scanning tunneling microscope (STM) tip is used to selectively desorb hydrogen atoms from the Si(100)-2X1:H surface by injecting electrons at a negative sample bias voltage. A new lithography method is disclosed that allows the STM to operate under imaging conditions and simultaneously desorb H atoms as required. A high frequency signal is added to the negative sample bias voltage to deliver the required energy for hydrogen removal. The resulted current at this frequency and its harmonics are filtered to minimize their effect on the operation of the STM's feedback loop. This approach offers a significant potential for controlled and precise removal of hydrogen atoms from a hydrogen-terminated silicon surface and thus may be used for the fabrication of practical silicon-based atomic-scale devices.

Moheimani, Seyed Omid Reza↗

Informative Path Planning for Mapping Radiation

This project involves making measurements of contaminated areas using portable radiation detectors and small robots. Tasks involve operating detectors and small robots, combining data acquisition for the two systems, and automating the systems. The end result is a radiation map of contamination areas. Localization of radioactive sources and mapping of contamination distribution is essential when responding to emergencies, or when dealing with cleanup efforts. Radiation maps are used for situational awareness and for establishing a safe perimeter. However, it may be hazardous or impossible for humans to safely enter the site and survey the area. Informative Path Planning (IPP) is used to design a path for a robotic sensor platform to gather the most information about the radiation distribution while operating under the set of constraints given by the dynamics of the robot and other requirements such as minimizing the overall mission time. The key challenge for IPP is the tight coupling in multiple layers of decisions: Selection of locations to visit; Allocation of sensors to those locations; Processing of information gathered. Given a robot equipped with a basic gamma detector and Lidar sensor, how can we efficiently explore an unknown environment in such a way that we can satisfy the robot's constraints while simultaneously maximizing the accuracy of the map and minimizing the total runtime? This work presents a systematic procedure for IPP and environmental mapping that: Selects the best locations at which to sample; Finds the best path for robots; Estimates the measurement value at unknown locations using a Gaussian Process regression framework. Given a set of points where radiation measurements were taken, we are utilizing a Gaussian Process Regression with a Matern kernel to reconstruct the shape of the underlying ground truth. Mapping is done via the Robot Operating System's OpenSlam Gmapping package, which creates a 2D occupancy grid map. Simulated trials were run with a radiation source placed at random locations, and allowing the robot to select and move towards 20 samples at separate locations, as well as sampling along the path while moving. The simulated sensor model assumed an efficiency of 0.3, collection time of 1 second. Various weighting schemes were tested and compared. Quantitative evaluations often favored exploitation-heavy weighting schemes where μ was emphasized, with the Root Mean Squared Error (RMSE) quickly tending towards 2, whereas qualitative comparisons would favor exploration-biased schemes with greater weight on σ. The difference comes from operators often favoring knowing the general location of a source, rather than the exact properties of a source. Weighting of the path-length π often reduced the quality of the regression as less exploration occurred, however this may be deemed a worthwhile trade-off under certain circumstances, such as with sensitive robots. Successfully developed a methodology for informative path-planning for a robot to efficiently gather information and create a map of radiation. In the future, we would like to focus on: Hardware trials with integration of the robot platform and the IPP software; More refined sensor and environmental modeling; Multiple robot platforms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiochemistry diagnostics for the National Ignition Facility

Radiochemistry-based techniques will be an important complement to x-ray implosion diagnostics. Simulations demonstrate the value of alpha-induced or deuteron-induced reactions as a direct measurement of static mix contamination in DT-filled ignition capsules. In this proceedings we examine to what extent neutron-induced reactions might be highly correlated with the energetically down-scattered neutron fraction which is, in turn, related to the critical quantity of fuel areal density, {rho}R. Although alpha and deuteron reactions are highly suppressed in HT/D-filled capsules, neutron-induced reactions produce robust abundances and 2% measurements of the relevant radiological ratios is achievable. We conclude that radiochemical data are strongly correlated with the down-scattered fraction and fuel areal density. Unknown physics, primarily uncertainties in the direct T-T fusion neutron cross section and, to a lesser extent, various radiochemical production cross sections are important but calibration shots can be used to reduce these errors. The primary advantage of radiochemistry remains - it is the only technique that samples down-scattered neutrons from the entire capsule during the burn. In particular radiochemistry correlated with other diagnostics can be used to minimize experimental uncertainties and thus maximize gain.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Exploration for Blind Geothermal Resources in the State of Hawaii Utilizing Dissolved Noble Gasses in Well Waters

This study is an extension of the Hawaii Play Fairway Analysis (PFA), a statewide geothermal exploration project funded by the United States Department of Energy. Based on results from prior phases of the PFA, this project targeted 66 wells on the islands of Hawaii, Maui, Lanai, Oahu, and Kauai for sampling of dissolved noble gases, trace metals, common ions, and the stable isotopes 2H and 18O. Ultimately, 23 of the 66 well targets were sampled. The noble gas helium is used as an indicator of geothermal heat when excess 3He and/or 4He is present when compared to the atmospheric ratio of those isotopes (R/Ra). R/Ra is minimally affected by dilution and transport, allowing even those wells not perfectly situated over a geothermal system to indicate a geothermal anomaly. R/Ra anomalies are present on every island in this study. There is a strong correlation between R/Ra anomalies and proximity to rift zones and calderas. Across the islands R/Ra ranged from 15-16 on Kilauea's lower east rift zone, which is a mantle plume value, to 0.37 on Lanai, which is a crustal value. The majority of anomalous well samples had R/Ra values consistent with an upper mantle source. Mixing between upper mantle and crustal helium is evident on all islands. Geographically, R/Ra decreases from the high at Kilauea to upper mantle values at Mauna Loa, and remains at upper mantle values for all wells across the other volcanoes, with the exception of two of four sampled wells on Lanai.

15 GEOTHERMAL ENERGY↗

A surface work function measurement technique utilizing constant deflected grazing electron trajectories: Oxygen uptake on Cu(001)

We report on the application of a novel nondestructive in-vacuum technique for relative work function measurements, employing a grazing incidence electron deflection above a sample with a planar surface. Two deflected electron beam detectors are used as a position sensitive detector to control feedback to the sample potential as the sample work function changes. With feedback the sample potential exactly follows the surface sample-size averaged work function variation, so that the deflected beam trajectory remains stable. We also discuss methods to optimize the initial electron trajectories for this method, so as to minimize unwanted effects such as from uncontrolled external magnetic fields. As the electron beam does not impinge on the surface in this new technique electron induced desorption, ionization, dissociation, and/or decomposition is not induced at the interface. Importantly also the technique allows for free access to the surfaces enabling simultaneous deposition/evaporation and/or application of other surface characterization methods. We demonstrate its application in concurrent measurements of helium atom reflectivity and work function changes taking place during molecular oxygen exposure of a Cu(001) surface. A work function measurement sensitivity and stability is demonstrated at {approx}10 mV at a sampling rate of 1 Hz and after application of an {approx}7 s smoothing routine. In comparison to the helium atom reflectivity measurements, the work function measurements are more sensitive to the initial O uptake, and less so to the final coverage variations and possible surface reordering at higher O coverages.

43 PARTICLE ACCELERATORS↗

XPS guide: Charge neutralization and binding energy referencing for insulating samples

This guide deals with methods to control surface charging during XPS analysis of insulating samples and approaches to extracting useful binding energy information. Furthermore, the guide summarizes the causes of surface charging, how to recognize when it occurs, approaches to minimize charge buildup, and methods used to adjust or correct XPS photoelectron binding energies when charge control systems are used. Additionally, there are multiple ways to control surface charge buildup during XPS measurements and examples of systems on advanced XPS instruments are described. There is no single, simple, and foolproof way to extract binding energies on insulating material, but advantages and limitations of several approaches are described. Because of the variety of approaches and limitations of each it is critical for researchers to accurately describe the procedures that have been applied in research reports and publications.

47 OTHER INSTRUMENTATION↗

On the Sampling-Based Computation of Nash Equilibria Under Uncertainty via the Nikaido–Isoda Function

We consider the computation of an equilibrium of a stochastic Nash equilibrium problem, where the player objectives are assumed to be L 0 -Lipschitz continuous and convex, given rival decisions with convex and closed player-specific feasibility sets. To address this problem, we consider minimizing a suitably defined value function defined using the Nikaido–Isoda function. Such an avenue does not necessitate either monotonicity properties of the concatenated gradient map or potentiality requirements on the game but does require a suitable regularity requirement under which a stationary point is a Nash equilibrium. We design and analyze a sampling-enabled projected-gradient-response method, reliant on inexact resolution of a player-level best-response subproblem. Here, by deriving suitable Lipschitzian guarantees on the value function, we derive both asymptotic guarantees for the sequence of generated iterates as well as rate and complexity guarantees for computing a stationary point by appropriate choices of the sampling rate and inexactness sequence.

Nikaido-Isoda function↗

JV Task 119 - Effects of Aging on Treated Activated Carbons

For both the United States and Canada, testing has been under way for electric utilities to find viable and economical mercury control strategies to meet pending future mercury emission limits. The technology that holds the most promise for mercury control in low-chlorine lignite to meet the needs of the Clean Air Act in the United States and the Canada-Wide Standards in Canada is injection of treated activated carbon (AC) into the flue gas stream. Most of the treated carbons are reported to be halogenated, often with bromine. Under a previous multiyear project headed by the Energy & Environmental Research Center (EERC), testing was performed on a slipstream unit using actual lignite-derived flue gas to evaluate various sorbent technologies for their effectiveness, performance, and cost. Testing under this project showed that halogenated ACs performed very well, with mercury capture rates often {ge} 90%. However, differences were noted between treated ACs with respect to reactivity and capacity, possibly as a result of storage conditions. Under certain conditions (primarily storage in ambient air), notable performance degradation had occurred in mercury capture efficiency. Therefore, a small exploratory task within this project evaluated possible differences resulting from storage conditions and subsequent effects of aging that might somehow alter their chemical or physical properties. In order to further investigate this potential degradation of treated (halogenated) ACs, the EERC, together with DOE's National Energy Technology Laboratory, the North Dakota Industrial Commission (NDIC), the Electric Power Research Institute (EPRI), SaskPower, and Otter Tail Power Company, assessed the aging effects of brominated ACs for the effect that different storage durations, temperatures, and humidity conditions have on the mercury sorption capacity of treated ACs. No aging effects on initial capture activity were observed for any carbons or conditions in the investigation. As measured by the 50% breakthrough time, no changes in capacity were observed for Norit LH samples stored frozen and likely none for Norit LH samples stored under high humidity conditions. The major aging effects on capacity for the EERC brominated sample were seen as a decrease in capacity during the first week of storage under high humidity conditions. Storage of the Norit LH and the EERC 5% brominated samples under low humidity conditions resulted in slightly improved capacities. Storage of the 15% brominated sample under high humidity conditions also improved the capacity. Surface analysis using x-ray photoelectron spectroscopy (XPS) showed some migration of bromine to and from the surface occurred during storage, although no net loss of bromine was observed. The migration to the surface in the case of the 15% brominated carbon correlates with the increased capacity observed for this sample. The XPS elemental speciation data for the EERC brominated carbons showed a trend toward more bromide being formed at the expense of covalent bromine during storage. This was especially great for the 15% and the 5% stored in low humidity. The Norit LH samples did not show this increase in bromide concentration. This is consistent with the lack of change in capacity for the Norit LH during storage. The carbon speciation data showed generally more oxidization of carbon surfaces with storage, especially formation of carboxylate groups. The least increase in carboxylate groups was seen for the Norit LH stored under low humidity, which correlates with its increased capacity. In conclusion, the observed changes in surface chemistry can be related to the minimal changes in capacity observed, but the factors operate in different directions, so the relationships are complex. High-quality x-ray absorption fine structure spectra were obtained for most of the samples. Significant changes were observed in the x-ray absorption near edge structure and extended x-ray absorption fine structure spectra of the stored carbons, but proved difficult to interpret and correlate with structural changes.

01 COAL, LIGNITE, AND PEAT↗

Trajectory Design and Maneuver Performance of the OSIRIS-REx Low-Altitude Reconnaissance of Bennu

With more than a year of asteroid proximity operations, the OSIRIS-REx team was able to identify one primary and one backup site for sample collection. The next step was to finalize on-board, localized image libraries and site-specific terrain information prior to attempting sample acquisition. Collecting this information required additional, low-altitude asteroid flyby reconnaissance activities. These activities, referred to as ‘sorties’, involved special maneuver and trajectory designs, unique from any other OSIRIS-REx maneuver activity. In order to minimize time between flybys and decrease the total number of maneuvers required, this trajectory design departed from and returned to a frozen Sun-terminator plane orbit within the span of a few hours. This work discusses the trajectory design and performance of the four flybys that were used to collect key topographic science observations of the primary and backup sample sites, which helped lead to a successful sample collection.

Andrew Levine↗

SU-E-J-158: Experimental Investigation of Proton Radiography Based On Time-Resolved Dose Measurements

Purpose: To use proton radiography for i) in-vivo range verification of the brain fields of medulloblastoma patients in order to reduce the exit dose to the cranial skin and thus the risk of permanent alopecia; ii) for performing patient specific optimization of the calibration from CT-Hounsfield units to proton relative stopping power in order to minimize uncertainties of proton rang Methods: We developed and tested a prototype proton radiography system based on a single-plane scintillation screen coupled with a fast CCD camera (1ms sampling rate, 0.29x0.29 mm{sup 2} pixel size, 30×30 cm{sup 2} field of view). The method is based on the principle that, for passively scattered beams, the radiological depth of any point in the plateau of a spread-out Bragg-Peak (SOBP) can be inferred from the time-pattern of the dose rate measurements. We performed detector characterization measurements using complex-shape homogeneous phantoms and an Alderson phanto Results: Detector characterization tests confirmed the robustness of the technique. The results of the phantom measurements are encouraging in terms of achievable accuracy of the water equivalent thickness. A technique to minimize the degradation of spatial resolution due to multiple Coulomb scattering is discussed. Our novel radiographic technique is rapid (100 ms) and simultaneous over the whole field. The dose required to produce one radiograph, with the current settings, is ∼3 cG Conclusion: The results obtained with this simple and innovative radiography method are promising and motivate further development of technique. The system requires only a single-plane 2D dosimeter and it uses the clinical beam for a fraction of second with low dose to the patient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of Inoculation with Lactic Acid Bacteria on the Preservation of Nannochloropsis gaditana Biomass in Wet Anaerobic Storage and Its Impact on Biomass Quality

Wet anaerobic storage of algal biomass is a promising preservation approach that can ensure a continuous supply of these feedstocks to biorefineries year-round. An effective solution to preservation must ensure minimal dry matter loss and a change in biochemical composition during storage. Therefore, the objective of this study is to investigate the preservation of Nannochloropsis gaditana biomass through wet anaerobic storage and its impact on biomass quality. Prior to storage, the algae sample is inoculated with two different strains of lactic acid bacteria and thereafter stored for 30 and 180 days. Each inoculant limited the dry matter loss to <10% (dry basis) after the storage duration. Final pH values (4.3–4.8) indicate that the biomass samples are properly ensiled, achieving the acidic conditions necessary for preservation. Compositional analysis of the biomass after storage shows a reduction in carbohydrate content, a relative increase in lipid content, and no significant change in the protein fraction. Glucose and galactose were the most prevalent sugar monomers. The low dry matter loss and minimal compositional change indicate that wet anaerobic storage is an effective means of preserving algal biomass and ensuring a constant supply of algal biomass feedstock to a biorefinery.

Oginni, Oluwatosin↗

Effects of autocorrelation upon LANDSAT classification accuracy

Richmond, Virginia and Denver, Colorado were study sites in an effort to determine the effect of autocorrelation on the accuracy of a parallelopiped classifier of LANDSAT digital data. The autocorrelation was assumed to decay to insignificant levels when sampled at distances of at least ten pixels. Spectral themes developed using blocks of adjacent pixels, and using groups of pixels spaced at least 10 pixels apart were used. Effects of geometric distortions were minimized by using only pixels from the interiors of land cover sections. Accuracy was evaluated for three classes; agriculture, residential and "all other"; both type 1 and type 2 errors were evaluated by means of overall classification accuracy. All classes give comparable results. Accuracy is approximately the same in both techniques; however, the variance in accuracy is significantly higher using the themes developed from autocorrelated data. The vectors of mean spectral response were nearly identical regardless of sampling method used. The estimated variances were much larger when using autocorrelated pixels.

Craig, R. G.↗

SU-G-JeP1-15: Sliding Window Prior Data Assisted Compressed Sensing for MRI Lung Tumor Tracking

Purpose: Prior Data Assisted Compressed Sensing (PDACS) is a partial k-space acquisition and reconstruction method for mobile tumour (i.e. lung) tracking using on-line MRI in radiotherapy. PDACS partially relies on prior data acquired at the beginning of dynamic scans, and is therefore susceptible to artifacts in longer duration scan due to slow drifts in MR signal. A novel sliding window strategy is presented to mitigate this effect. Methods: MRI acceleration is simulated by retrospective removal of data from the fully sampled sets. Six lung cancer patients were scanned (clinical 3T MRI) using a balanced steady state free precession (bSSFP) sequence for 3 minutes at approximately 4 frames per second, for a total of 650 dynamics. PDACS acceleration is achieved by undersampling of k-space in a single pseudo-random pattern. Reconstruction iteratively minimizes the total variations while constraining the images to satisfy both the currently acquired data and the prior data in missing k-space. Our novel sliding window technique (SW-PDACS), uses a series of distinct pseudo-random under-sampling patterns of partial k-space – with the prior data drawn from a sliding window of the most recent data available. Under-sampled data, simulating 2 – 5x acceleration are reconstructed using PDACS and SW-PDACS. Three quantitative metrics: artifact power, centroid error and Dice’s coefficient are computed for comparison. Results: Quantitively metric values from all 6 patients are averaged in 3 bins, each containing approximately one minute of dynamic data. For the first minute bin, PDACS and SW-PDACS give comparable results. Progressive decline in image quality metrics in bins 2 and 3 are observed for PDACS. No decline in image quality is observed for SW-PDACS. Conclusion: The novel approach presented (SW-PDACS) is a more robust for accelerating longer duration (>1 minute) dynamic MRI scans for tracking lung tumour motion using on-line MRI in radiotherapy. B.G. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗