Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Informed-Proteomics: open-source software package for top-down proteomics

Top-down proteomics involves the analysis of intact proteins. This approach is very attractive as it allows for analyzing proteins in their endogenous form without proteolysis, preserving valuable information about post-translation modifications, isoforms, proteolytic processing or their combinations collectively called proteoforms. Moreover, the quality of the top-down LC-MS/MS datasets is rapidly increasing due to advances in the liquid chromatography and mass spectrometry instrumentation and sample processing protocols. However, the top-down mass spectra are substantially more complex compare to the more conventional bottom-up data. To take full advantage of the increasing quality of the top-down LC-MS/MS datasets there is an urgent need to develop algorithms and software tools for confident proteoform identification and quantification. In this study we present a new open source software suite for top-down proteomics analysis consisting of an LC-MS feature finding algorithm, a database search algorithm, and an interactive results viewer. The presented tool along with several other popular tools were evaluated using human-in-mouse xenograft luminal and basal breast tumor samples that are known to have significant differences in protein abundance based on bottom-up analysis.

Environmental Molecular Sciences Laboratory↗

A Study on Efficient Reinforcement Learning Through Knowledge Transfer

Although Reinforcement Learning (RL) algorithms have made impressive progress in learning complex tasks over the past years, there are still prevailing short-comings and challenges. Specifically, the sample-inefficiency and limited adaptation across tasks often make classic RL techniques impractical for real-world applications despite the gained representational power when combining deep neural networks with RL, known as Deep Reinforcement Learning (DRL). Recently, a number of approaches to address those issues have emerged. Many of those solutions are based on smart DRL architectures that enhance single task algorithms with the capability to share knowledge between agents and across tasks by introducing Transfer Learning (TL) capabilities. Here this survey addresses strategies of knowledge transfer from simple parameter sharing to privacy preserving federated learning and aims at providing a general overview of the field of TL in the DRL domain, establishes a classification framework, and briefly describes representative works in the area.

97 MATHEMATICS AND COMPUTING↗

Learning with Delayed Rewards—A Case Study on Inverse Defect Design in 2D Materials

Defect dynamics in materials are of central importance to a broad range of technologies from catalysis to energy storage systems to microelectronics. Material functionality depends strongly on the nature and organization of defects-their arrangements often involve intermediate or transient states that present a high barrier for transformation. The lack of knowledge of these intermediate states and the presence of this energy barrier presents a serious challenge for inverse defect design, especially for gradient-based approaches. Here, we present a reinforcement learning (RL) [Monte Carlo Tree Search (MCTS)] based on delayed rewards that allow for efficient search of the defect configurational space and allows us to identify optimal defect arrangements in low-dimensional materials. Using a representative case of two-dimensional MoS 2 , we demonstrate that the use of delayed rewards allows us to efficiently sample the defect configurational space and overcome the energy barrier for a wide range of defect concentrations (from 1.5 to 8% S vacancies)-the system evolves from an initial randomly distributed S vacancies to one with extended S line defects consistent with previous experimental studies. Detailed analysis in the feature space allows us to identify the optimal pathways for this defect transformation and arrangement. Comparison with other global optimization schemes like genetic algorithms suggests that the MCTS with delayed rewards takes fewer evaluations and arrives at a better quality of the solution. The implications of the various sampled defect configurations on the 2H to 1T phase transitions in MoS 2 are discussed. In this study, we introduce a RL strategy employing delayed rewards that can accelerate the inverse design of defects in materials for achieving targeted functionality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-Stage Estimation and Variance Modeling for Latency-Constrained Variational Quantum Algorithms

The quantum approximate optimization algorithm (QAOA) has enjoyed increasing attention in noisy, intermediate-scale quantum computing with its application to combinatorial optimization problems. QAOA has the potential to demonstrate a quantum advantage for NP-hard combinatorial optimization problems. As a hybrid quantum-classical algorithm, the classical component of QAOA resembles a simulation optimization problem in which the simulation outcomes are attainable only through a quantum computer. The simulation that derives from QAOA exhibits two unique features that can have a substantial impact on the optimization process: (i) the variance of the stochastic objective values typically decreases in proportion to the optimality gap, and (ii) querying samples from a quantum computer introduces an additional latency overhead. In this paper, we introduce a novel stochastic trust-region method derived from a derivative-free, adaptive sampling trust-region optimization method intended to efficiently solve the classical optimization problem in QAOA by explicitly taking into account the two mentioned characteristics. The key idea behind the proposed algorithm involves constructing two separate local models in each iteration: a model of the objective function and a model of the variance of the objective function. Exploiting the variance model allows us to restrict the number of communications with the quantum computer and also helps navigate the nonconvex objective landscapes typical in QAOA optimization problems. In conclusion, we numerically demonstrate the superiority of our proposed algorithm using the SimOpt library and Qiskit when we consider a metric of computational burden that explicitly accounts for communication costs.

Derivative-free Optimization↗

The completed SDSS-IV extended baryon oscillation spectroscopic survey: geometry and growth from the anisotropic void–galaxy correlation function in the luminous red galaxy sample

ABSTRACT We present an analysis of the anisotropic redshift-space void–galaxy correlation in configuration space using the Sloan Digital Sky Survey extended Baryon Oscillation Spectroscopic Survey (eBOSS) Data Release 16 luminous red galaxy (LRG) sample. This sample consists of LRGs between redshifts 0.6 and 1.0, combined with the high redshift z > 0.6 tail of the Baryon Oscillation Spectroscopic Survey Data Release 12 CMASS sample. We use a reconstruction method to undo redshift-space distortion (RSD) effects from the galaxy field before applying a watershed void-finding algorithm to remove bias from the void selection. We then perform a joint fit to the multipole moments of the correlation function for the growth rate fσ8 and the geometrical distance ratio DM/DH, finding $f\sigma _8(z_\rm {eff})=0.356\pm 0.079$ and $D_M/D_H(z_\rm {eff})=0.868\pm 0.017$ at the effective redshift $z_\rm {eff}=0.69$ of the sample. The posterior parameter degeneracies are orthogonal to those from galaxy clustering analyses applied to the same data, and the constraint achieved on DM/DH is significantly tighter. In combination with the consensus galaxy BAO and full-shape analyses of the same sample, we obtain fσ8 = 0.447 ± 0.039, DM/rd = 17.48 ± 0.23, and DH/rd = 20.10 ± 0.34. These values are in good agreement with the ΛCDM model predictions and represent reductions in the uncertainties of $13{{\ \rm per\ cent}}$, $23{{\ \rm per\ cent}}$, and $28{{\ \rm per\ cent}}$, respectively, compared to the combined results from galaxy clustering, or an overall reduction of 55 per cent in the allowed volume of parameter space.

Nadathur, Seshadri↗

Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate

Purpose: Elekta accelerators controlled by the current clinically used accelerator control system, Desktop 7.01 (D7), uses binned variable dose rate (BVDR) for volumetric modulated arc therapy (VMAT). The next version of the treatment control system (Integrity) supports continuously variable dose rate (CVDR) as well as BVDR. Using CVDR opposed to BVDR for VMAT has the potential of reducing the treatment time but may lead to lower dosimetric accuracy due to faster moving accelerator parts. Using D7 and a test version of Integrity, differences in ability to control the accelerator, treatment efficiency, and dosimetric accuracy between the two systems were investigated. Methods: Single parameter tests were designed to expose differences in the way the two systems control the movements of the accelerator. In these tests, either the jaws, multi leaf collimators (MLCs), or gantry moved at constant speed while the dose rate was changed in discrete steps. The positional errors of the moving component and dose rate were recorded using the control systems with a sampling frequency of 4 Hz. The clinical applicability of Integrity was tested using 15 clinically used VMAT plans (5 prostate, 5 H and N, and 5 lung) generated by the SmartArc algorithm in PINNACLE. The treatment time was measured from beam-on to beam-off and the accuracy of the dose delivery was assessed by comparing DELTA4 measurements and PINNACLE calculated doses using gamma evaluation. Results: The single parameter tests showed that Integrity had an improved feedback between gantry motion and dose rate at the slight expense of MLC control compared to D7. The single parameter test did not reveal any significant differences in the control of either jaws or backup jaws between the two systems. These differences in gantry and MLC control together with the use of CVDR gives a smoother Integrity VMAT delivery compared to D7 with less abrupt changes in accelerator motion. Gamma evaluation (2% of 2 Gy and 2 mm) of the calculated doses and DELTA4 measured doses corrected for systematic errors showed an average pass rate of more than 97.8% for both D7, Integrity BVDR, and Integrity CVDR deliveries. Direct comparisons between the measured doses using strict gamma criteria of 0.5% and 0.5 mm showed excellent agreement between D7 and Integrity delivered doses with average pass rates above 95.7%. Finally, the Integrity control system resulted in a significant 35% (55 {+-} 13 s) reduction in treatment time, on average. Conclusions: Single parameter tests showed that the two control systems differed in their feedback loops between MLC, gantry, and dose rate. These differences made the VMAT deliveries more smooth using the new Integrity treatment control system, compared to the current Desktop 7.01. Together with the use of CVDR, which results in less abrupt changes in dose rate, this further increases the smoothness of the delivery. The use of CVDR for VMAT with the Integrity desktop results in a significant reduction in treatment time compared to BVDR with an average reduction of 35%. This decrease in delivery time was achieved without compromising the dosimetric accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

First Cosmology Results using Supernovae Ia from the Dark Energy Survey: Survey Overview, Performance, and Supernova Spectroscopy

We present details on the observing strategy, data-processing techniques, and spectroscopic targeting algorithms for the first three years of operation for the Dark Energy Survey Supernova Program (DES-SN). This five-year program using the Dark Energy Camera mounted on the 4 m Blanco telescope in Chile was designed to discover and follow supernovae (SNe) Ia over a wide redshift range (0.05 < z < 1.2) to measure the equation-of-state parameter of dark energy. We describe the SN program in full: strategy, observations, data reduction, spectroscopic follow-up observations, and classification. From three seasons of data, we have discovered 12,015 likely SNe, 308 of which have been spectroscopically confirmed, including 251 SNe Ia over a redshift range of 0.017 < z < 0.85. We determine the effective spectroscopic selection function for our sample and use it to investigate the redshift-dependent bias on the distance moduli of SNe Ia we have classified. The data presented here are used for the first cosmology analysis by DES-SN (“DES-SN3YR”), the results of which are given in Dark Energy Survey Collaboration et al. The 489 spectra that are used to define the DES-SN3YR sample are publicly available at https://des.ncsa.illinois.edu/releases/sn.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid evaluation of particle properties using inverse SEM simulations

The characteristic X-rays produced by the interactions of the electron beam with the sample in a scanning electron microscope (SEM) are usually captured with a variable-energy detector, a process termed energy dispersive spectrometry (EDS). The purpose of this work is to exploit inverse simulations of SEM-EDS spectra to enable rapid determination of sample properties, particularly elemental composition. This is accomplished using penORNL, a modified version of PENELOPE, and a modified version of the traditional Levenberg Marquardt nonlinear optimization algorithm, which together is referred to as MOZAIK-SEM. The overall conclusion of this work is that MOZAIK-SEM is a promising method for performing inverse analysis of X-ray spectra generated within a SEM. As this methodology exists now, MOZAIK-SEM has been shown to calculate the elemental composition of an unknown sample within a few percent of the actual composition.

Bekar, Kursat B↗

Analysis of Time Dependent Data and PRA

In the past decades, several numerical simulation codes have been employed to simulate accident dynamics (e.g., RELAP5-3D, MELCOR, MAAP). In order to evaluate the impact of uncertainties into accident dynamics, several stochastic methodologies have been coupled with these codes. These stochastic methods range from classical Monte-Carlo and Latin Hypercube sampling to stochastic polynomial methods. Similar approaches have been introduced into the risk and safety community where stochastic methods (such as RAVEN, ADAPT, MCDET, ADS) have been coupled with safety analysis codes in order to evaluate the safety impact of timing and sequencing of events. These approaches are usually called Dynamic PRA or simulation-based PRA methods. These uncertainties and safety methods usually generate a large number of simulation runs (database storage may be on the order of gigabytes or higher). The scope of this paper is to present a broad overview of methods and algorithms that can be used to analyze and extract information from large data sets containing time dependent data. In this context, 'extracting information' means constructing input-output correlations, finding commonalities, and identifying outliers. Some of the algorithms presented here have been developed or are under development within the RAVEN statistical framework. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Disentangling instrumental features of the 130 GeV Fermi line

We study the instrumental features of photons from the peak observed at E{sub γ} = 130 GeV in the spectrum of Fermi-LAT data. We use the sPlots algorithm to reconstruct — seperately for the photons in the peak and for background photons — the distributions of quantities such as incident angles, the recorded time, features of the spacecraft position, the zenith angles, the conversion type and details of the energy and direction reconstruction. The presence of a striking feature or cluster in such a variable would suggest an instrumental cause for the peak. In the publically available data, we find several suggestive features which may inform further studies by instrumental experts, though the size of the signal sample is too small to draw statistically significant conclusions.

79 ASTRONOMY AND ASTROPHYSICS↗

A Pilot Evaluation of a 4-Dimensional Cone-Beam Computed Tomographic Scheme Based on Simultaneous Motion Estimation and Image Reconstruction

Purpose: To evaluate the performance of a 4-dimensional (4-D) cone-beam computed tomographic (CBCT) reconstruction scheme based on simultaneous motion estimation and image reconstruction (SMEIR) through patient studies. Methods and Materials: The SMEIR algorithm contains 2 alternating steps: (1) motion-compensated CBCT reconstruction using projections from all phases to reconstruct a reference phase 4D-CBCT by explicitly considering the motion models between each different phase and (2) estimation of motion models directly from projections by matching the measured projections to the forward projection of the deformed reference phase 4D-CBCT. Four lung cancer patients were scanned for 4 to 6 minutes to obtain approximately 2000 projections for each patient. To evaluate the performance of the SMEIR algorithm on a conventional 1-minute CBCT scan, the number of projections at each phase was reduced by a factor of 5, 8, or 10 for each patient. Then, 4D-CBCTs were reconstructed from the down-sampled projections using Feldkamp-Davis-Kress, total variation (TV) minimization, prior image constrained compressive sensing (PICCS), and SMEIR. Using the 4D-CBCT reconstructed from the fully sampled projections as a reference, the relative error (RE) of reconstructed images, root mean square error (RMSE), and maximum error (MaxE) of estimated tumor positions were analyzed to quantify the performance of the SMEIR algorithm. Results: The SMEIR algorithm can achieve results consistent with the reference 4D-CBCT reconstructed with many more projections per phase. With an average of 30 to 40 projections per phase, the MaxE in tumor position detection is less than 1 mm in SMEIR for all 4 patients. Conclusion: The results from a limited number of patients show that SMEIR is a promising tool for high-quality 4D-CBCT reconstruction and tumor motion modeling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SeismoGen: Seismic Waveform Synthesis Using GAN With Application to Seismic Data Augmentation

Abstract Detecting earthquake arrivals within seismic time series can be a challenging task. Visual, human detection has long been considered the gold standard but requires intensive manual labor that scales poorly to large data sets. In recent years, automatic detection methods based on machine learning have been developed to improve the accuracy and efficiency. However, the accuracy of those methods relies on access to a sufficient amount of high‐quality labeled training data, often tens of thousands of records or more. We aim to resolve this dilemma by answering two questions: (1) provided with a limited amount of reliable labeled data, can we use them to generate additional, realistic synthetic waveform data? and (2) can we use those synthetic data to further enrich the training set through data augmentation, thereby enhancing detection algorithms? To address these questions, we use a generative adversarial network (GAN), a type of machine learning model which has shown supreme capability in generating high‐quality synthetic samples in multiple domains. Once trained, our GAN model is capable of producing realistic seismic waveforms of multiple labels (noise and event classes). Applied to real Earth seismic data sets in Oklahoma, we show that data augmentation from our GAN‐generated synthetic waveforms can be used to improve earthquake detection algorithms in instances when only small amounts of labeled training data are available.

Wang, Tiantong↗

acdc – Automated Contamination Detection and Confidence estimation for single-cell genome data

Abstract Background A major obstacle in single-cell sequencing is sample contamination with foreign DNA. To guarantee clean genome assemblies and to prevent the introduction of contamination into public databases, considerable quality control efforts are put into post-sequencing analysis. Contamination screening generally relies on reference-based methods such as database alignment or marker gene search, which limits the set of detectable contaminants to organisms with closely related reference species. As genomic coverage in the tree of life is highly fragmented, there is an urgent need for a reference-free methodology for contaminant identification in sequence data. Results We present acdc, a tool specifically developed to aid the quality control process of genomic sequence data. By combining supervised and unsupervised methods, it reliably detects both known and de novo contaminants. First, 16S rRNA gene prediction and the inclusion of ultrafast exact alignment techniques allow sequence classification using existing knowledge from databases. Second, reference-free inspection is enabled by the use of state-of-the-art machine learning techniques that include fast, non-linear dimensionality reduction of oligonucleotide signatures and subsequent clustering algorithms that automatically estimate the number of clusters. The latter also enables the removal of any contaminant, yielding a clean sample. Furthermore, given the data complexity and the ill-posedness of clustering, acdc employs bootstrapping techniques to provide statistically profound confidence values. Tested on a large number of samples from diverse sequencing projects, our software is able to quickly and accurately identify contamination. Results are displayed in an interactive user interface. Acdc can be run from the web as well as a dedicated command line application, which allows easy integration into large sequencing project analysis workflows. Conclusions Acdc can reliably detect contamination in single-cell genome data. In addition to database-driven detection, it complements existing tools by its unsupervised techniques, which allow for the detection of de novo contaminants. Our contribution has the potential to drastically reduce the amount of resources put into these processes, particularly in the context of limited availability of reference species. As single-cell genome data continues to grow rapidly, acdc adds to the toolkit of crucial quality assurance tools.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of leaf motion constraints on IMAT plan quality, deliver accuracy, and efficiency

Purpose: Intensity modulated arc therapy (IMAT) is a radiation therapy delivery technique that combines the efficiency of arc based delivery with the dose painting capabilities of intensity modulated radiation therapy (IMRT). A key challenge in developing robust inverse planning solutions for IMAT is the need to account for the connectivity of the beam shapes as the gantry rotates from one beam angle to the next. To overcome this challenge, inverse planning solutions typically impose a leaf motion constraint that defines the maximum distance a multileaf collimator (MLC) leaf can travel between adjacent control points. The leaf motion constraint ensures the deliverability of the optimized plan, but it also impacts the plan quality, the delivery accuracy, and the delivery efficiency. In this work, the authors have studied leaf motion constraints in detail and have developed recommendations for optimizing the balance between plan quality and delivery efficiency. Methods: Two steps were used to generate optimized IMAT treatment plans. The first was the direct machine parameter optimization (DMPO) inverse planning module in the Pinnacle{sup 3} planning system. Then, a home-grown arc sequencer was applied to convert the optimized intensity maps into deliverable IMAT arcs. IMAT leaf motion constraints were imposed using limits of between 1 and 30 mm/deg. Dose distributions were calculated using the convolution/superposition algorithm in the Pinnacle{sup 3} planning system. The IMAT plan dose calculation accuracy was examined using a finer sampling calculation and the quality assurance verification. All plans were delivered on an Elekta Synergy with an 80-leaf MLC and were verified using an IBA MatriXX 2D ion chamber array inserted in a MultiCube solid water phantom. Results: The use of a more restrictive leaf motion constraint (less than 1-2 mm/deg) results in inferior plan quality. A less restrictive leaf motion constraint (greater than 5 mm/deg) results in improved plan quality but can lead to less accurate dose distribution as evidenced by increasing discrepancies between the planned and the delivered doses. For example, the results from our patient-specific quality assurance measurements demonstrated that the average gamma analysis passing rate decreased from 98% to 80% when the allowable leaf motion increased from 3 to 20 mm/deg. Larger leaf motion constraints also led to longer treatment delivery times (2 to 4 folds) due to the additional MLC leaf motion. Conclusions: Leaf motion constraints significantly impact IMAT plans in terms of plan quality, delivery accuracy, and delivery efficiency with the impact magnified for more complex cases. Our studies indicate that a leaf motion constraint of 2 to 3 mm/deg of gantry rotation can provide an optimal balance between plan quality, delivery accuracy, and efficiency.

61 RADIATION PROTECTION AND DOSIMETRY↗

GPU acceleration of the Locally Selfconsistent Multiple Scattering code for first principles calculation of the ground state and statistical physics of materials

The Locally Self-consistent Multiple Scattering (LSMS) code solves the first principles Density Functional theory Kohn–Sham equation for a wide range of materials with a special focus on metals, alloys and metallic nano-structures. It has traditionally exhibited near perfect scalability on massively parallel high performance computer architectures. In this paper, we present our efforts to exploit GPUs to accelerate the LSMS code to enable first principles calculations of O(100,000) atoms and statistical physics sampling of finite temperature properties. We reimplement the scattering matrix calculation for GPUs with a block matrix inversion algorithm that only uses accelerator memory. Finally, using the Cray XK7 system Titan at the Oak Ridge Leadership Computing Facility we achieve a sustained performance of 14.5PFlop/s and a speedup of 8.6 compared to the CPU only code.

36 MATERIALS SCIENCE↗

Continuous-time probabilistic models for longitudinal electronic health records

Analysis of longitudinal Electronic Health Record (EHR) data is an important goal for precision medicine. Difficulty in applying Machine Learning (ML) methods, either predictive or unsupervised, stems in part from the heterogeneity and irregular sampling of EHR data. Here, we present an unsupervised probabilistic model that captures nonlinear relationships between variables over continuous-time. This method works with arbitrary sampling patterns and captures the joint probability distribution between variable measurements and the time intervals between them. Inference algorithms are derived that can be used to evaluate the likelihood of future using under a trained model. As an example, we consider data from the United States Veterans Health Administration (VHA) in the areas of diabetes and depression. Likelihood ratio maps are produced showing the likelihood of risk for moderate-severe vs minimal depression as measured by the Patient Health Questionnaire-9 (PHQ-9).

59 BASIC BIOLOGICAL SCIENCES↗

Predicting boron coordination in multicomponent borate and borosilicate glasses using analytical models and machine learning

Accurate prediction of boron coordination in multicomponent glasses is critical in glass science and technology as it strongly affects the properties of borate and borosilicate glasses. We have collected a dataset containing 657 glasses from literature with boron coordination values and developed models using analytical functions based on the well accepted Dell, Xiao and Bray model. Good prediction of boron coordination with a R 2 value higher than 0.8 was obtained. The large variation of boron coordination from experiments, originated from sample preparations and characterizations, led to difficulties in obtaining models with better prediction performance. Various machine learning (ML) algorithms were evaluated and slightly better prediction performance was observed; however, interpretation of the ML models is less straight forward. In conclusion, this study developed various models capable of providing quantitative boron coordination predictions, providing insights into its structural roles in multi-component glasses, and suggesting fruitful areas for future research.

36 MATERIALS SCIENCE↗

Coherent diffraction study of calcite crystallization during the hydration of tricalcium silicate

The aim of this work is using Bragg coherent X-ray diffraction imaging (BCDI) to study the calcite crystallization during carbonation of hydrated tricalcium silicate (C 3 S). Portland cement is a very complex synthesized product whose 50–70% mass is composed of C 3 S, which is the most important phase to produce calcium silicate hydrates and calcium hydroxide. Hence, its hydration contributes greatly to the hydration of cement and later to the carbonation of cement products when it reacts with CO 2 , often from the air, to form calcium carbonates. BCDI has emerged in the last decade as a promising high-resolution lens-less imaging approach for characterization of various samples. It has made significant progress with the development of X-ray sources and phase-retrieval algorithms. BCDI allows for imaging the whole three-dimensional structure of micro- and sub-micro- crystalline materials and can show the strain distribution at the nanometer spatial resolution. Finally, results show that calcite crystallization follows a through-solution reaction and the growth model of the calcite crystal can be explained by using “phase domain” theory. In conclusion, during carbonation, calcite crystals grow by increasing the number of phase domains within them while the domain size remains at about 200–300 nm.

36 MATERIALS SCIENCE↗