Search NASA⌕ Search

SEARCH · Search NASA

Results for “separations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Molten hydroxide membrane for separation of acid gases from emissions

In one embodiment, a separation membrane includes: a porous support structure; and at least one alkali metal hydroxide disposed within pores of the porous support structure. In another embodiment, a method for separating acidic gases from a gas mixture includes exposing the gas mixture to a separation membrane at an elevated temperature, where the separation membrane includes a porous support and at least one molten alkali metal hydroxide disposed within pores of the porous support.

54 ENVIRONMENTAL SCIENCES↗

Improved methods for separation of Cobalt, Manganese, Nickel, Lithium from Waste Lithium-ion Battery Scrap

Improved methods for separation of Cobalt, Manganese, Nickel, Lithium from Waste Lithium-ion Battery Scrap Mark L. Strauss1, John Klaehn1 Luis Diaz Aldana1, Tedd Lister1 Idaho National Laboratory1, Biological and Chemical Processing Department, Idaho Falls, Idaho 83415 ABSTRACT The current methods for the separation of Co, Mn, Ni, Li require that the leach solution have a pH between 2-4 in order to use many Cyanex cationic exchange products. Using a unique buffer solution for the reagent combined with the leachate of innovative electrochemical leaching process for lithium batteries demonstrates the separation is possible without a large of pH modification as other commercial hydrometallugical separation process. This research demonstrates a process that is more environmentally sustainable because the reagent consumption may be less. The corresponding McCable-Thiele diagrams and number of theoretical stages were determined to achieve a 80-90% purity of cobalt, manganese, nickel and lithium.

42 ENGINEERING↗

Development of Two-Phase Dense Fluid Expander for Advanced Cryogenic Air Separation and Low-Grade Heat Recovery

Cryogenic air separation represents the state-of-the-art technology to produce oxygen to feed coal gasification units. Given the maturity of this technology, it is difficult to identify opportunities to improve process efficiency and reduce the cost of the oxygen produced. However, Air Products conducted research and a feasibility investigation into the use of a two-phase (liquid-vapor) dense fluid expander (DFE) to improve the overall efficiency of cryogenic air separation. Demonstration of this novel concept was intended to allow two important process improvements: 1) elimination of the need for the DFE discharge to be single phase 2) expansion of the operating region of expanders in ASU service. Expanding the scope of turboexpander application beyond current application limits and traditional device designs would allow an increase in power recovery, and application of refrigeration and power recovery at new locations in process cycles would also enable the implementation of new process concepts. These new process concepts include power recovery from compression waste heat and refrigeration extraction and power recovery by replacing let-down valves with two-phase DFEs. Considering the maturity of cryogenic air separation, these new process options could represent a step change in power reduction and provide significant savings in operating costs. These new concepts would be particularly well-suited to large-scale oxygen production by cryogenic air separation and would enhance the economics of producing oxygen for use in coal gasification processes. Rotoflow, an Air Products business unit, manufactures dense fluid expanders in Pennsylvania for sites around the world. This project was executed in two phases, which are illustrated in Figure 1 below. Phase 1 consisted of a feasibility investigation of multiple applications of two-phase DFEs. In Phase 2, devices were identified, designed, fabricated and tested to explore the feasibility of commercial applications of DFEs operating in two-phase service. Engineering and testing were performed by personnel in Air Products’ Rotoflow business unit, with coordination with other Air Products business units.

01 COAL, LIGNITE, AND PEAT↗

Process for component separation utilizing miscibility depression near a freezing point

A process for separating a mixture of components is disclosed. A liquid mixture is provided to a separation vessel substantially near a temperature at which a product component freezes. The liquid mixture comprises the product component and a carrier component. The product component and the carrier component are essentially immiscible substantially near the temperature. The liquid mixture is separated into two or more phases, the two or more phases comprising a product component-rich liquid phase and a product component-depleted liquid phase. In this manner, a mixture of components is separated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heavy metal separations using strongly paramagnetic column packings in a nonhomogeneous magnetic field

The present invention is directed to a method for the separation of an actinide from another metal. The method comprises the following steps: (a) establishing a non-homogeneous magnetic field across a separation column containing a paramagnetic packing material and (b) providing a fluid containing the actinide and the another metal to the separation column wherein the fluid and the paramagnetic packing material are exposed to the non-homogeneous magnetic field. The non-homogeneous magnetic field is produced by a magnet having a first pole for magnetic interaction with a second pole of the magnet wherein the first pole has a different surface area than the second pole. The non-homogeneous magnetic field has a magnetic field gradient of about 500 lines/cm 2 /cm or more. In addition, the present invention is also directed to a method for the separation of one heavy metal from another heavy metal.

36 MATERIALS SCIENCE↗

Simple chemical method for the separation of rare earth metals

A method is provided for separating mixtures of different rare earth metals using a ligand having a size-sensitive molecular aperture. The present invention meets the needs in the field by providing method of separating and purifying rare earth metals. The object of this invention is to separate and purify rare earth metals, e.g., the more valuable Dy away from Nd, in mixtures containing such metals using a simple chemical process without the need for countercurrent liquid-liquid separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On-board separation of oxygenates from fuels

Methods for separation of oxygenates or other chemical components from fuels using chemical processes and separations including, but not limited to, onboard applications in vehicles. These separations may take place using a variety of materials and substances whereby a target material of interest is captured, held, and then released at a desired location and under desired conditions. In one set of experiments we demonstrated an enhancement in the separation of diaromatics by >38 times over gasoline and aromatics by >3.5 times over gasoline. This would give an advantage to reducing cold-start emissions, or emissions during transient conditions, in either gasoline or diesel.

Bays, John T.↗

Two-phase separator device for removing condensate or particulate from a gas stream

This disclosure provides a two-phase separator device for separating condensate or particulate from a gas stream. In some implementations, the separator device removes water from air and may operate under micro-gravity conditions. The gas stream flows through the two-phase separator device and passes through a rotatable vane assembly along a flow path without being redirected in another flow path. Condensate or particulate in the gas stream is impacted by a plurality of vanes of the rotatable vane assembly, and the condensate is captured by features formed within the plurality of vanes. The captured condensate is accelerated radially outwardly along the each of the plurality of vanes towards a sloped inner wall, and further moved along the sloped inner wall in a direction against the flow path of the gas stream during rotation.

Cognata, Thomas↗

Extraction chromatographic separation of Am(III) and Eu(III) by TPEN-immobilized gel

A TPEN derivative with 4 vinyl groups, N,N,N',N' -tetrakis-(4-propenyloxy-2-pyridylmethyl)ethylenediamine (TPPEN) was synthesized for the separation of trivalent minor actinides (Am(III)) and lanthanides (Eu(III)). A co-polymer gel with TPPEN and N-isopropylacrylamide (NIPA) showed a high separation factor of Am(III) over Eu(III) (SF[Am/Eu]), which was evaluated to be 26 at pH=5. Thin film of NIPA-TPPEN gel (average thickness: 2-40 nm) was immobilized on the pore surface in porous silica particles (particle diameter : 50 μm, average pore diameter : 50 and 300 nm) and a chromatographic column (diameter: 6 mm, height: 11 mm) packed with the gel-coated particles was prepared. A small amount of weakly acidic solution (pH=4) containing Am(III) and Eu(III) was supplied in the column and the elution tests of Am(III) and Eu(III) were carried out. Eu(III) was recovered separately by a weakly acidic eluent (pH=4) at 313 K and Am(III) by a highly acidic eluent (pH=2) at 298 K. These results suggest that the contentious separation of minor actinides and lanthanides is attainable by a new extraction chromatographic process with two columns adjusted to 298 K and 313 K. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Rapid Sequential Separation Method for Determination of Actinides and TENORM in Fracking Wastes - 20223

With recent advances in unconventional drilling technology in the US and around the world, the risks of environmental contamination and exposure due to technologically enhanced naturally occurring radioactive materials (TENORM) from fracking wastes have also surfaced. Although the Permian Basin (southeastern New Mexico, western Texas) has long been a modest producer of oil, the advent of fracking technology a decade ago turned it into hot property for producers. A 2018 assessment of undiscovered, technically recoverable continuous oil and gas resources by the U.S. Geological Survey estimates an average 46.3 billion barrels of oil and 281 trillion cubic feet of gas. This is likely to increase the use of unconventional drilling and TENORM generation. TENORM concentrations in oil and gas exploration and production waste can be several hundred to several thousand times higher than background TENORM concentrations. Both the thorium and uranium decay chains contribute to airborne radionuclides arising from the radon gas escaping the ground and subsequently decaying as airborne particulates. Additionally, radon decay products {sup 210}Pb and {sup 210}Po can build up in scale on the internal surfaces of oil and gas handling pipes and in sludge in refineries, becoming potential inhalation and ingestion hazards for workers. Furthermore, southeastern NM is also home to world's only licensed and operating transuranic nuclear waste repository, the DoE's Waste Isolation Pilot Plant (WIPP). Plutonium isotopes ({sup 239+240}Pu) and {sup 241}Am, are expected to account for more than 99% of the total radioactivity scheduled for disposal in the WIPP repository. Thus, an improved understanding of the environmental fate and transport of TENORM, liberated by unconventional drilling, is essential to assess how best to protect individuals and the environment. In this context, accurate measurement of TENORM and actinides in environmental and biological samples is essential. In this presentation, a new sequential method for the separation and pre-concentration of actinides (Pu, Am, Np) and TENORM (Po, U and Th) derived from oil and gas exploration is proposed. The TEVA method involves a rapid co-precipitation step to remove matrix interferences from the samples, followed by plutonium oxidation state adjustment to Pu (IV) and an incubation period of ∼ 1 hour at 50-60 deg. C to allow the resultant Po (II) to oxidize into Po(IV). The polonium, neptunium, thorium and plutonium are then separated on a TEVA column, while americium and uranium are separated on a TRU column. After separation, the alpha counting source was prepared by micro-precipitation with copper sulfide (CuS) for polonium and neodymium fluoride (NdF{sub 3}) for actinides. The efficiency and reliability of the procedures were tested by analyzing filter, drinking water and frack sand samples. The method is simple, robust and can be performed quickly with excellent removal of interferences, high chemical recovery and very good alpha peak resolution. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Separation of compounds

A method for separating liquids is disclosed. A feed stream is passed into a separator. The feed stream comprising an organic compound, carbon dioxide, and oxides selected from the group consisting of sulfur oxides, nitrogen oxides, ozone and combinations thereof. A portion an organic-rich stream is separated from a portion of an inorganic-rich stream through separation by gravity. The organic-rich stream contains a portion of the organic compound and a first portion of the carbon dioxide. The inorganic-rich stream contains a portion of the oxides and a second portion of the carbon dioxide.

Baxter, Larry↗

Ionic Liquid Membranes for Carbon Dioxide Separation

Recent scientific studies are rapidly advancing novel technological improvements and engineering developments that demonstrate the ability to minimize, eliminate, or facilitate the removal of various contaminants and green house gas emissions in power generation. The Integrated Gasification Combined Cycle (IGCC) shows promise for carbon dioxide mitigation not only because of its higher efficiency as compared to conventional coal firing plants, but also due to a higher driving force in the form of high partial pressure. One of the novel technological concepts currently being developed and investigated is membranes for carbon dioxide (CO2) separation, due to simplicity and ease of scaling. A challenge in using membranes for CO2 capture in IGCC is the possibility of failure at elevated temperatures or pressures. Our earlier research studies examined the use of ionic liquids on various supports for CO2 separation over the temperature range, 37°C-300°C. The ionic liquid, 1-hexyl-3methylimidazolium Bis(trifluoromethylsulfonyl)imide, ([hmim][Tf2N]), was chosen for our initial studies with the following supports: polysulfone (PSF), poly(ether sulfone) (PES), and cross-linked nylon. The PSF and PES supports had similar performance at room temperature, but increasing temperature caused the supported membranes to fail. The ionic liquid with the PES support greatly affected the glass transition temperature, while with the PSF, the glass transition temperature was only slightly depressed. The cross-linked nylon support maintained performance without degradation over the temperature range 37-300°C with respect to its permeability and selectivity. However, while the cross-linked nylon support was able to withstand temperatures, the permeability continued to increase and the selectivity decreased with increasing temperature. Our studies indicated that further testing should examine the use of other ionic liquids, including those that form chemical complexes with CO2 based on amine interactions. The hypothesis is that the performance at the elevated temperatures could be improved by allowing a facilitated transport mechanism to become dominant. Several amine-based ionic liquids were tested on the cross-linked nylon support. It was found that using the amine-based ionic liquid did improve selectivity and permeability at higher temperature. The hypothesis was confirmed, and it was determined that the type of amine used also played a role in facilitated transport. Given the appropriate aminated ionic liquid with the cross-linked nylon support, it is possible to have a membrane capable of separating CO2 at IGCC conditions. With this being the case, the research has expanded to include separation of other constituents besides CO2 (CO, H2S, etc.) and if they play a role in membrane poisoning or degradation. This communication will discuss the operation of the recently fabricated ionic liquid membranes and the impact of gaseous components other than CO2 on their performance and stability.

01 COAL, LIGNITE, AND PEAT↗

Separation of Minor Actinides from Lanthanides by Dithiophosphinic Acid Extractants

The selective extraction of the minor actinides (Am(III) and Cm(III)) from the lanthanides is an important part of advanced reprocessing of spent nuclear fuel. This separation would allow the Am/Cm to be fabricated into targets and recycled to a reactor and the lanthanides to be dispositioned. This separation is difficult to accomplish due to the similarities in the chemical properties of the trivalent actinides and lanthanides. Research efforts at the Idaho National Laboratory have identified an innovative synthetic pathway yielding new regiospecific dithiophosphinic acid (DPAH) extractants. The synthesis provides DPAH derivatives that can address the issues concerning minor actinide separation and extractant stability. For this work, two new symmetric DPAH extractants have been prepared. The use of these extractants for the separation of minor actinides from lanthanides will be discussed.

99 GENERAL AND MISCELLANEOUS↗

Separation of Yeast Cells from MS2 Viruses Using Acoustic Radiation Force

We report a rapid and robust separation of Saccharomyces cerevisiae and MS2 bacteriophage using acoustic focusing in a microfluidic device. A piezoelectric transducer (PZT) generates acoustic standing waves in the microchannel. These standing waves induce acoustic radiation force fields that direct microparticles towards the nodes (i.e., pressure minima) or the anti-nodes (i.e., pressure maxima) of the standing waves depending on the relative compressidensity between the particle and the suspending liquid.[1] For particles larger than 2 {micro}m, the transverse velocities generated by these force fields enable continuous, high throughput separation. Extensive work in the last decade [2-4] has demonstrated acoustic focusing for manipulating microparticles or biological samples in microfluidic devices. This prior work has primarily focused on experimental realization of acoustic focusing without modeling or with limited one-dimensional modeling estimates. We recently developed a finite element modeling tool to predict the two-dimensional acoustic radiation force field perpendicular to the flow direction in microfluidic devices.[1] Here we compare results from this model with experimental parametric studies including variations of the PZT driving frequencies and voltages as well as various particle sizes and compressidensities. These experimental parametric studies also provide insight into the development of an adjustable 'virtual' pore-size filter as well as optimal operating conditions for various microparticle sizes. Figure 1 shows a typical experimental acoustic focusing result for microparticles (diameter = 2.0 {micro}m) in a 500 {micro}m wide by 200 {micro}m deep microchannel. In this case, the PZT driving frequency and voltage are, respectively, 1.459 MHz and 6.6 V. The microparticles tightly focus (full width half maximum (FWHM) {approx}30 {micro}m) less than 30 s after the initiation of the acoustic field. We simulated the same geometry and operating conditions for comparison. The surface plot in Figure 2 illustrates the two-dimensional pressure field orthogonal to the flow direction (x-direction) from the simulation. The superimposed vector plot shows the acoustic radiation force in this plane. The dark regions and the light regions respectively represent the nodes and anti-nodes of the acoustic pressure field. The corresponding force field predicts acoustic focusing at the center of the microchannel, which is confirmed by the experimental results shown in Figure 1. We demonstrated the separation of Saccharomyces cerevisiae (typical cell size of 4-6 {micro}m depending on the cell growth stage, measured using a Coulter counter) and MS2 bacteriophage (typical diameter {approx}30 nm [5]) using acoustic focusing (Figure 3). A mixture of S. cerevisiae and MS2 labeled with Ribogreen was prepared and injected into one inlet of the microchip (i.e., half of the microchannel was filled with the sample). We varied driving voltages from 1.96 to 4.76 V, while fixing the driving frequency at 1.459 MHz and flow rate at 20 {micro}l/min. The acoustic radiation force did not affect the MS2 viruses, and their concentration profile remained unchanged. Increased driving voltages enhanced the acoustic focusing of the yeast cells thereby achieving good separation. We are able to achieve yields of > 80% and sample purities of > 90% in this continuous-flow sample preparation device.

42 ENGINEERING↗

A multi-channel gel electrophoresis and continuous fraction collection apparatus for high throughput protein separation and characterization

To facilitate a direct interface between protein separation by PAGE and protein identification by mass spectrometry, we developed a multichannel system that continuously collects fractions as protein bands migrate off the bottom of gel electrophoresis columns. The device was constructed using several short linear gel columns, each of a different percent acrylamide, to achieve a separation power similar to that of a long gradient gel. A Counter Free-Flow elution technique then allows continuous and simultaneous fraction collection from multiple channels at low cost. We demonstrate that rapid, high-resolution separation of a complex protein mixture can be achieved on this system using SDS-PAGE. In a 2.5 h electrophoresis run, for example, each sample was separated and eluted into 48-96 fractions over a mass range of 10-150 kDa; sample recovery rates were 50percent or higher; each channel was loaded with up to 0.3 mg of protein in 0.4 mL; and a purified band was eluted in two to three fractions (200 L/fraction). Similar results were obtained when running native gel electrophoresis, but protein aggregation limited the loading capacity to about 50 g per channel and reduced resolution.

60 APPLIED LIFE SCIENCES↗

Separation and Recovery of Uranium Metal from Spent Light Water Reactor Fuel via Electrolytic Reduction and Electrorefining

A series of bench-scale experiments was performed in a hot cell at Idaho National Laboratory to demonstrate the separation and recovery of uranium metal from spent light water reactor (LWR) oxide fuel. The experiments involved crushing spent LWR fuel to particulate and separating it from its cladding. Oxide fuel particulate was then converted to metal in a series of six electrolytic reduction runs that were performed in succession with a single salt loading of molten LiCl – 1 wt% Li2O at 650 °C. Analysis of salt samples following the series of electrolytic reduction runs identified the diffusion of select fission products from the spent fuel to the molten salt electrolyte. The extents of metal oxide conversion in the post-test fuel were also quantified, including a nominal 99.7% conversion of uranium oxide to metal. Uranium metal was then separated from the reduced LWR fuel in a series of six electrorefining runs that were performed in succession with a single salt loading of molten LiCl-KCl-UCl3 at 500 °C. Analysis of salt samples following the series of electrorefining runs identified additional partitioning of fission products into the molten salt electrolyte. Analyses of the separated uranium metal were performed, and its decontamination factors were determined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hyperaging Tuning of a Carbon Molecular-Sieve Hollow Fiber Membrane with Extraordinary Gas-Separation Performance and Stability

Here, we report 6FDA:BPDA-DAM polyimide-derived hollow fiber carbon molecular-sieve (CMS) membranes for hydrogen and ethylene separation. Since H 2 /C 2 H 4 selectivity is the lowest among H 2 /(C 1 -C 3 ) hydrocarbons, an optimized CMS fiber for this gas pair is useful for removing hydrogen from all-cracked gas mixtures. A process we term hyperaging provides highly selective CMS fiber membranes by tuning CMS ultramicropores to favor H 2 over larger molecules to give a H 2 /C 2 H 4 selectivity of over 250. Hyperaging conditions and a hyperaging mechanism are discussed in terms of an expedited physical aging process, which is largely controlled by the hyperaging temperature. For the specific CMS material considered here, a hyperaging temperature beyond 90°C but less than 250°C works best. Hyperaging also stabilizes CMS materials against physical aging and stabilizes the performance of H 2 separation over extended periods. This research opens a door in the development of CMS materials for the separation of small molecules from large molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separation of terbium from proton-irradiated gadolinium oxide targets – development of an effective, scalable and automatable process

This work reports an effective and scalable radiochemical separation process for isolating terbium from Gd 2 O 3 . The separation process uses three commercially available extraction chromatography resin columns, has been implemented on a computer-controlled chemistry module, and tested with 100 mg quantities of proton-irradiated nat Gd 2 O 3 . Here, the 4-hour separation procedure isolated radioterbium in 1.3 mL of 0.01 M HCl with 80 ±8% radiochemical yield and a Gd decontamination factor >(1.2 ± 0.3)·10 5 .

Adjacent lanthanide separation↗