Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Gamma/neutron time-correlation for special nuclear material detection – Active stimulation of highly enriched uranium

A series of simulations and experiments were undertaken to explore and evaluate the potential for a novel new technique for fissile material detection and characterization, the timecorrelated pulse-height (TCPH) method, to be used concurrent with active stimulation of potential nuclear materials. In previous work TCPH has been established as a highly sensitive method for the detection and characterization of configurations of fissile material containing Plutonium in passive measurements. By actively stimulating fission with the introduction of an external radiation source, we have shown that TCPH is also an effective method of detecting and characterizing configurations of fissile material containing Highly Enriched Uranium (HEU). The TCPH method is shown to be robust in the presence of the proper choice of external radiation source. An evaluation of potential interrogation sources is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A CHANDRA OBSERVATION OF THE NEARBY SCULPTOR GROUP Sd GALAXY NGC 7793

We conducted a Chandra ACIS observation of the nearby Sculptor Group Sd galaxy NGC 7793 as part of a multiwavelength study of supernova remnants (SNRs) in nearby galaxies. At the assumed distance to NGC 7793 of 3.91 Mpc, the limiting unabsorbed luminosity of the detected discrete X-ray sources is L{sub X} (0.2-10.0 keV) {approx}3x10{sup 36} erg s{sup -1}. A total of 22 discrete sources were detected at the {approx}3{sigma} level or greater including one ultraluminous X-ray source (ULX). Based on multiwavelength comparisons, we identify X-ray sources coincident with one SNR, the candidate microquasar N7793-S26, one H II region, and two foreground Galactic stars. We also find that the X-ray counterpart to the candidate radio SNR R3 is time variable in its X-ray emission: we therefore rule out the possibility that this source is a single SNR. A marked asymmetry is seen in the distribution of the discrete sources with the majority lying in the eastern half of this galaxy. All of the sources were analyzed using quantiles to estimate spectral properties and spectra of the four brightest sources (including the ULX) were extracted and analyzed. We searched for time variability in the X-ray emission of the detected discrete sources using our measured fluxes along with fluxes measured from prior Einstein and Roentgensatellit observations. From this study, three discrete X-ray sources are established to be significantly variable. A spectral analysis of the galaxy's diffuse emission is characterized by a temperature of kT = 0.19-0.25 keV. The luminosity function of the discrete sources shows a slope with an absolute value of {Gamma} = -0.65 {+-} 0.11 if we exclude the ULX. If the ULX is included, the luminosity function has a long tail to high L{sub X} with a poor-fitting slope of {Gamma} = -0.62 {+-} 0.2. The ULX-less slope is comparable to the slopes measured for the distributions of NGC 6946 and NGC 2403 but much shallower than the slopes measured for the distributions of IC 5332 and M83. Lastly, we comment on the multiwavelength properties of the SNR population of NGC 7793.

79 ASTRONOMY AND ASTROPHYSICS↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nano-metrology: The art of measuring X-ray mirrors with slope errors <100 nrad

We present a comprehensive investigation of the systematic and random errors of the nano-metrology instruments used to characterize synchrotron X-ray optics at Diamond Light Source. With experimental skill and careful analysis, we show that these instruments used in combination are capable of measuring state-of-the-art X-ray mirrors. Examples are provided of how Diamond metrology data have helped to achieve slope errors of <100 nrad for optical systems installed on synchrotron beamlines, including: iterative correction of substrates using ion beam figuring and optimal clamping of monochromator grating blanks in their holders. Simulations demonstrate how random noise from the Diamond-NOM’s autocollimator adds into the overall measured value of the mirror’s slope error, and thus predict how many averaged scans are required to accurately characterize different grades of mirror.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrophobic amine-based binary mixtures of active pharmaceutical and food grade ingredients: characterization and application in indium extraction from aqueous hydrochloric acid media

The wide spread use of hazardous and expensive solvents for the liquid-liquid extraction (LLE) of critical metals has been a growing source of waste in the metal refinement industry. We have developed and characterized room temperature liquid hydrophobic binary mixtures based on common pharmaceutical and food grade compounds as sustainable, cost effective alternatives to both ionic liquids and conventional solvents. Additionally, we introduce liquid mixtures with Proton Sponge® (1,8-bis(dimethylamino)naphthalene), one of the strongest known organic bases. These mixtures have been applied to the LLE of indium(III) ions from hydrochloric acid solutions, displaying an extraction efficiency greater than 99% in some systems. Here, a systematic approach to identifying the underlying mechanism of extraction, in particular relating to the charge, solubility, and complexation of the indium species in the organic phase has been developed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Main components of PM10 in an area influenced by a cement plant in Catalonia, Spain: Seasonal and daily variations

Highlights: • Constituents and main components of airborne PM{sub 10} near a cement plant were studied. • A clear seasonality was found, with higher levels in winter. • A daily pattern was not observed, when comparing weekdays and weekends. • Road traffic had a significant contribution to PM{sub 10} levels. Particulate matter (PM) composition has a key role in a wide range of health outcomes, such as asthma, chronic obstructive pulmonary disease, lung cancer, cardiovascular disease, and death, among others. Montcada i Reixac, a municipality located in the Barcelona metropolitan area (Catalonia, Spain), for its location and orography, is an interesting case- study to investigate air pollution. The area is also characterized by the presence of different industrial emission sources, including a cement factory and a large waste management plant, as well as an intense traffic. In this study, PM{sub 10} levels, trace elements, ions, and carbonaceous particles were determined for a long time period (2013–2016) in this highly polluted area. PM{sub 10} samples were collected during six consecutive days in two campaigns (cold and warm) per year. A number of elements (As, Ba, Be, Bi, Ca, Cd, Ce, Co, Cr, Cs, Cu, Dy, Er, Eu, Fe, Ga, Gd, Ge, Hf, Hg, Ho, K, La, Li, Hg, Mg, Mn, Mo, Nb, Nd, Ni, Pb, Pr, Rb, Sb, Sc, Se, Sm, Sn, Sr, Tb, Th, Ti, Tl, U, V, W, Y, Yb, and Zr), ions (Cl{sup -}, SO{sub 4}{sup 2-}, NO{sub 3}{sup -}, and NH{sub 4}{sup +}), and carbonaceous content (total carbon, organic plus elemental carbon, and CO{sub 3}{sup 2-}), were analysed. These data were used to identify the PM{sub 10} main components: mineral matter, sea spray, secondary inorganic aerosols, organic matter plus elemental carbon, trace elements or indeterminate fraction. Although a clear seasonality (cold vs. warm periods) was found, there were no differences between working days and weekends. Obviously, the cement plant influences the surrounding environment. However, no differences in trace elements related with the cement plant activity (Al, Ca, Ni and V) between weekdays and weekends were noted. However, some traffic-related elements (i.e., Co, Cr, Mn, and Sb) showed significantly higher concentrations in weekdays.

54 ENVIRONMENTAL SCIENCES↗

Application of a Geochemically Informed Leak Detection (GILD) Model to CO 2 Injection Sites on the United States Gulf Coast

The Gulf Coast region possesses great potential for CO 2 enhanced oil recovery (EOR) and CO 2 storage. A geochemically informed leak detection (GILD) model has been applied to CO 2 injection sites on the Gulf Coast with considerations of measurement variability. The Jasper aquifer in Montgomery County, Texas, was chosen to demonstrate the method. Based on background data from wells in the area, combinations of mineral and fluid compositions were used to create 23 scenarios for the geochemical model. The output from the geochemical model was used to identify sensitive monitoring species, and response functions were generated for these as a function of the CO 2 leakage concentration. The sources of measurement variability for background conditions were characterized from the Jasper aquifer background data, and then normalized using the coefficient of variation of each species across the monitoring wells. Bayesian belief network (BBN) models were constructed, and measurement variability of different levels were added to compare leak detection probabilities. Increasing measurement variability decreased the power to detect a leak of a given size. For a moderately high CO 2 concentration of 0.2 mol/kg, the probability of detecting this leakage effect using pH as the monitoring variable in an aquifer with calcite decreases from 98% (no measurement variability) to 61% (medium variability) to 33% (high variability). The loss in power of the sampling protocol with increasing measurement variability is similar in magnitude when Ca 2+ or HCO 3 - is used as the monitoring parameter, but only for aquifers with calcite.

58 GEOSCIENCES↗

Quantifying groundwater travel time near managed recharge operations using 35S as an intrinsic tracer

By identifying groundwater retention times near managed aquifer recharge (MAR) facilities is a high priority for managing water quality, especially for operations that incorporate recycled wastewater. In order to protect public health, California guidelines for Groundwater Replenishment Reuse Projects require a minimum 2–6 month subsurface retention time for recycled water depending on the level of disinfection, which highlights the importance of quantifying groundwater travel times on short time scales. This study developed and evaluated a new intrinsic tracer method using the naturally occurring radioisotope sulfur-35 (35S). The 87.5 day half-life of 35S is ideal for investigating groundwater travel times on the <1 year timescale of interest to MAR managers. Natural concentrations of 35S found in water as dissolved sulfate (35SO4) were measured in source waters and groundwater at the Rio Hondo Spreading Grounds in Los Angeles County, CA, and Orange County Groundwater Recharge Facilities in Orange County, CA. 35SO4 travel times are comparable to travel times determined by well-established deliberate tracer studies. The study also revealed that 35SO4 in MAR source water can vary seasonally and therefore careful characterization of 35SO4 is needed to accurately quantify groundwater travel time. But, more data is needed to fully assess whether or not this tracer could become a valuable tool for managers.

54 ENVIRONMENTAL SCIENCES↗

Simple polyol route to synthesize heptanoic acid coated magnetite (Fe{sub 3}O{sub 4}) nanoparticles

Highlights: ► Heptanoic acid@Fe{sub 3}O{sub 4} nanocomposite has been prepared via simple polyol. ► Heptanoic acid used as both surfactant and solvents. ► Magneto polymer composite with adjustable Ea has a potential usage as functional composites. - Abstract: Magnetite (Fe{sub 3}O{sub 4}) nanoparticles were prepared via polyol method by using FeCl{sub 2} as only source of iron. As-prepared samples were characterized by powder X-ray diffractometer (XRD), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), thermal gravimetric analyzer (TGA) and vibrating sample magnetometer (VSM). Crystalline phase was identified as Fe{sub 3}O{sub 4} and the crystallite sizes were calculated as 19.1 ± 1.1 and 22 ± 1.3 nm for uncalcinated and calcinated products from X-ray line profile fitting. The capping of heptanoic acid around Fe{sub 3}O{sub 4} nanoparticles was confirmed by FT-IR spectroscopy, the interaction being via bridging oxygen's of the carboxylate and the nanoparticle surface and also by TG analysis. VSM measurements showed that both samples exhibited typical superparamagnetic behavior at room temperature with different Ms values. The ε′ decreases with increasing frequency for both composites and permeability has almost same values for all temperatures at higher frequencies. As synthesized and calcinated samples conductivity increase linearly with the temperature.

36 MATERIALS SCIENCE↗

Upgrade of the CAESium-iodide scintillator ARray (CAESAR) electronics and data acquisition system for optimized performance at FRIB

Here, we report on the upgrade of the electronics and data acquisition (DAQ) of the high-efficiency CAESium-iodide scintillator ARray (CAESAR) at the Facility for Rare Isotope Beams (FRIB). With the on-going capability ramp-up of FRIB, CAESAR is expected to continue to be an in-demand -ray spectrometer owing to its high detection efficiency, compactness, and modularity, enabling easy integration with additional detection and DAQ systems. Within this context, the CAESAR electronics and DAQ were upgraded to remove obsolete modules, enhance the ease of integration with external instruments, and optimize the DAQ live time. We present the comprehensive results from offline (γ-ray sources) and online (in-beam experiment) commissioning, characterizing the performance of CAESAR’s new electronics and DAQ.

CsI(Na) scintillator array↗

Improved physiologically based pharmacokinetic model for oral exposures to chromium in mice, rats, and humans to address temporal variation and sensitive populations

A physiologically based pharmacokinetic (PBPK) model for hexavalent chromium [Cr(VI)] in mice, rats, and humans developed previously (Kirman et al., 2012, 2013), was updated to reflect an improved understanding of the toxicokinetics of the gastrointestinal tract following oral exposures. Improvements were made to: (1) the reduction model, which describes the pH-dependent reduction of Cr(VI) to Cr(III) in the gastrointestinal tract under both fasted and fed states; (2) drinking water pattern simulations, to better describe dosimetry in rodents under the conditions of the NTP cancer bioassay; and (3) parameterize the model to characterize potentially sensitive human populations. Important species differences, sources of non-linear toxicokinetics, and human variation are identified and discussed within the context of human health risk assessment. - Highlights: • An improved version of the PBPK model for Cr(VI) toxicokinetics was developed. • The model incorporates data collected to fill important data gaps. • Model predictions for specific age groups and sensitive subpopulations are provided. • Implications to human health risk assessment are discussed.

60 APPLIED LIFE SCIENCES↗

A high sensitivity ultralow temperature RF conductance and noise measurement setup

We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milli-Kelvin temperatures. The setup relies on the combination of an interferometric amplification scheme and a quarter-wave impedance transformer, allowing the measurement of noise power spectral densities with gigahertz bandwidth up to five orders of magnitude below the amplifier noise floor. We simultaneously measure the high frequency conductance of the sample by derivating a portion of the signal to a microwave homodyne detection. We describe the principle of the setup, as well as its implementation and calibration. Finally, we show that our setup allows to fully characterize a subnanosecond on-demand single electron source. More generally, its sensitivity and bandwidth make it suitable for applications manipulating single charges at GHz frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis of Mesoporous Adsorbent and its Application for Heavy Metal Ions Removal from Aqueous Solution

The mesoporous silicas were synthesized via the evaporation-induced self-assembly (EISA) in the experiment. Cetyltrimethyl ammonium bromide (CTAB) was used as the template, and the silicon source was tetraethoxyorthosilicate (TEOS). The mesoporous silicas were characterized by nitrogen adsorption-desorption analysis, FTIR, TEM and SEM. The mesoporous silicas (adsorbent) exhibited higher pore diameter (centered at 5.57 nm), BET surface area (457.3 m{sup 2{center_dot}}g{sup -1}) and pore volume (0.563 cm{sup 2{center_dot}}g{sup -1}). The mesoporous silicas were used as the adsorbent to remove the heavy metal ions from aqueous solution. The following order of equilibrium adsorption capacity for Cu{sup 2+}, Co{sup 2+}, Ag{sup +} and As{sup 3+} on adsorbent was: Ag{sup +}>Cu{sup 2+}>Co{sup 2+}>As{sup 3+}. Analysis of adsorption kinetics showed that Cu{sup 2+}, Co{sup 2+}, Ag{sup +} and As{sup 3+} adsorption fit the pseudo-second-order nonlinear model significantly. The removal rate for heavy metal ions was high, and the adsorbent can be regenerated by acid treatment without altering its properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Betatron radiation based measurement of the electron-beam size in a wakefield accelerator

We present a spatial and spectral characterization of a laser-plasma based betatron source which allows us to determine the betatron oscillation amplitude of the electrons which decreases with increasing electron energies. Due to the observed oscillation amplitude and the independently measured x-ray source size of (1.8{+-}0.3){mu}m we are able to estimate the electron bunch diameter to be (1.6{+-}0.3){mu}m.

43 PARTICLE ACCELERATORS↗

Infrared spectroscopy of the methanol cation and its methylene-oxonium isomer

The carbenium ion with nominal formula [C,H{sub 4},O]{sup +} is produced from methanol or ethylene glycol in a pulsed-discharge supersonic expansion source. The ion is mass selected, and its infrared spectrum is measured from 2000 to 4000 cm{sup −1} using laser photodissociation spectroscopy and the method of rare gas atom tagging. Computational chemistry predicts two isomers, the methanol and methylene-oxonium cations. Predicted vibrational spectra based on scaled harmonic and reduced dimensional treatments are compared to the experimental spectra. The methanol cation is the only isomer produced when methanol is used as a precursor. When ethylene glycol is used as the precursor, methylene-oxonium is produced in addition to the methanol cation. Theoretical results at the CCSD(T)/cc-pVTZ level show that methylene-oxonium is lower in energy than methanol cation by 6.4 kcal/mol, and is in fact the global minimum isomer on the [C,H{sub 4},O]{sup +} potential surface. Methanol cation is trapped behind an isomerization barrier in our source, providing a convenient method to produce and characterize this transient species. Analysis of the spectrum of the methanol cation provides evidence for strong CH stretch vibration/torsion coupling in this molecular ion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of electrode distance and nature of electrolyte on the diameter of titanium dioxide nanotube

The titanium nanotubes were synthesized using viscous electrolytes consisting of ethylene glycol and non-viscous electrolytes consisting of aqueous solution of hydrofluoric acid. Sodium fluoride and ammonium fluoride were utilized as the source of fluorine ions. The samples were then characterized by field emission scanning electron microscope (FE-SEM). Their morphologies were investigated under different anodic potentials and various electrolyte compositions. It was found out that nanotubes can be obtained in fluoride ions and morphology is dependent on various parameters like anodic potential, time, electrolyte composition and the effects by varying the distance between the electrodes on the morphology was also investigated. It was found that by altering the distance between the electrodes, change in the diameter and the porosity was observed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Free energy of metal-organic framework self-assembly

Metal-organic frameworks (MOFs) represent an important class of materials. Careful selection of building blocks allows for tailoring of the properties of the resulting framework. The self-assembly process, however, is not understood, and without detailed knowledge of the underlying molecular mechanism, it is difficult to anticipate whether a particular design can be realized, or whether the material adopts a metastable, kinetically arrested state. We present a detailed examination of early-stage self-assembly pathways of the MOF-5. Enhanced sampling techniques are used to model a self-assembly in an explicit solvent (dimethylformamide, DMF). We identify several free energy barriers encountered during the assembly of the final MOF, which arise from structural rearrangements preceding MOF formation and from disrupted MOF-solvent interactions as formation proceeds. In all cases considered here, MOFs exhibit favorable entropic gains during the assembly. More generally, the strategy presented provides a step toward the experimental design characterizing the formation of ordered frameworks and possible sources of polymorphism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗