Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Characterization of Collection Efficiency of the Common Research Model Midspan Wing Section in the IRT

This paper presents a preliminary study for the characterization of collection efficiency from icing tests conducted in the Icing Research Tunnel at NASA Glenn Research Center. A test method previously developed for measuring the attachment line maximum collection efficiency of a swept NACA 0012 airfoil model at zero angle of attack was applied to the leading-edge region of a 65%-scale version of the Common Research Model midspan wing section. A correlation for the stagnation line maximum collection efficiency as a function of the modified inertia parameter was obtained with LEWICE3D simulations utilizing a discrete number of drop diameters. It was then compared with the collection efficiency measurement data obtained in the IRT. For the experimental collection efficiency, two ice shape digitization procedures were utilized to extract 2-D chord-wise ice shape profiles, i.e., the Maximum Combined Cross Section or MCCS, and the Minimum Combined Cross Section or Min CCS, at selected span-wise locations from the 3-D scanned ice shapes. The preliminary result showed that the rime ice thickness method can be used to characterize the collection efficiency distribution, for conditions free of ice erosion, in the main ice shape region. However, a high-order statistical processing of the ice scan is needed for estimating the mean ice thickness in areas where feathers are prevalent. From the limited comparison of the experimental and LEWICE3D collection efficiency data in the CRM65 MS model leading edge area, it was shown that the attachment line maximum collection efficiency is reasonably estimated by the best curve-fit correlation in the range of modified inertia parameter tested. A tighter alignment control of the iced and cold clean model scans is needed to improve the comparison. Further evaluation of this correlation is recommended to assess its applicability for Common Research Model type swept wing icing scaling analysis.

Ice Scailing↗

Characterization of Collection Efficiency of the Common Research Model Midspan Wing Section in the IRT

This paper presents a preliminary study for the characterization of collection efficiency from icing tests conducted in the Icing Research Tunnel at NASA Glenn Research Center. A test method previously developed for measuring the attachment line maximum collection efficiency of a swept NACA 0012 airfoil model at zero angle of attack was applied to the leading-edge region of a 65%-scale version of the Common Research Model midspan wing section. A correlation for the stagnation line maximum collection efficiency as a function of the modified inertia parameter was obtained with LEWICE3D simulations utilizing a discrete number of drop diameters. It was then compared with the collection efficiency measurement data obtained in the IRT. For the experimental collection efficiency, two ice shape digitization procedures were utilized to extract 2-D chord-wise ice shape profiles, i.e., the Maximum Combined Cross Section or MCCS, and the Minimum Combined Cross Section or MinCCS, at selected span-wise locations from the 3-D scanned ice shapes. The preliminary result showed that the rime ice thickness method can be used to characterize the collection efficiency distribution, for conditions free of ice erosion, in the main ice shape region. However, a high-order statistical processing of the ice scan is needed for estimating the mean ice thickness in areas where feathers are prevalent. From the limited comparison of the experimental and LEWICE3D collection efficiency data in the CRM65 MS model leading edge area, it was shown that the attachment line maximum collection efficiency is reasonably estimated by the best curve-fit correlation in the range of modified inertia parameter tested. A tighter alignment control of the iced and cold clean model scans as well as the model angle of attack are needed to improve the comparison. Further evaluation of this correlation is recommended to assess its applicability for Common Research Model type swept wing icing scaling analysis.

Icing Scaling↗

Infrared-enhanced Photometric Redshifts for the Dark Energy Survey Y6 Gold catalogue

The Dark Energy Survey (DES) provides optical data across 5000 square degrees of the southern sky, enabling a broad range of extragalactic and cosmological studies. Combining DES data with infrared surveys offers the opportunity to improve its photometric redshift (photo-z) estimates. We aim to investigate improvements in photometric redshift estimation achieved by combining DES optical data with infrared measurements from the VISTA Hemisphere Survey (VHS) and the Wide-field Infrared Survey Explorer (WISE), and release an updated version of the catalogue. We performed a positional sky cross-match between the DES Y6 Gold catalogue matched to a spectroscopic dataset, the 2013 AllWISE Data Release, and VHS Data Release 5, in order to test these improvements using the Directional Neighbourhood Fitting (DNF) algorithm (Y6 Gold catalogue reference estimator). We additionally matched it to the unWISE catalogue to verify the performance against this deeper dataset. Adding infrared data reduces all the metrics (scatter, bias and outlier fraction) in photo-z estimates, particularly at higher redshifts in comparison with only using optical data from DES. The obtained results are globally better for the DES+WISE sample, with improvements that are statistically significant. On the other hand, the addition of the VHS bands to available depth is only marginal. The combined use of DES and WISE W1 and W2 data improves the photometric redshift metrics analysed here. The addition of VHS data at the DES and VHS depths explored here does not provide any further improvement at z less than 1.5, indicating that, under these constraints, WISE data may already capture the key infrared features and depth needed for accurate photo-z estimation. In addition, low signal-to-noise (less than 10) infrared data does not contribute to any improvement beyond the DES optical dataset.

Puebla, M. M. [Madrid U.; Madrid, CIEMAT]↗

Planck intermediate results. XX. Comparison of polarized thermal emission from Galactic dust with simulations of MHD turbulence

Polarized emission observed by Planck HFI at 353 GHz towards a sample of nearby fields is presented, focusing on the statistics of polarization fractions p and angles ψ. The polarization fractions and column densities in these nearby fields are representative of the range of values obtained over the whole sky. We find that: (i) the largest polarization fractions are reached in the most diffuse fields; (ii) the maximum polarization fraction p max decreases with column density N H in the more opaque fields with N H > 10 21 cm -2 ; and (iii) the polarization fraction along a given line of sight is correlated with the local spatial coherence of the polarization angle. These observations are compared to polarized emission maps computed in simulations of anisotropic magnetohydrodynamical turbulence in which we assume a uniform intrinsic polarization fraction of the dust grains. We find that an estimate of this parameter may be recovered from the maximum polarization fraction p max in diffuse regions where the magnetic field is ordered on large scales and perpendicular to the line of sight. This emphasizes the impact of anisotropies of the magnetic field on the emerging polarization signal. The decrease of the maximum polarization fraction with column density in nearby molecular clouds is well reproduced in the simulations, indicating that it is essentially due to the turbulent structure of the magnetic field: an accumulation of variously polarized structures along the line of sight leads to such an anti-correlation. In the simulations, polarization fractions are also found to anti-correlate with the angle dispersion function S. However, the dispersion of the polarization angle for a given polarization fraction is found to be larger in the simulations than in the observations, suggesting a shortcoming in the physical content of these numerical models. In summary, we find that the turbulent structure of the magnetic field is able to reproduce the main statistical properties of the dust polarization as observed in a variety of nearby clouds, dense cores excluded, and that the large-scale field orientation with respect to the line of sight plays a major role in the quantitative analysis of these statistical properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer

Abstract Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard χ2 method and maximum likelihood based on Poisson (C) statistics. The difference is studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn Kα calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the χ2 method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of ∼5 eV and a line with about 100 photons, the line width becomes ∼10% lower in the χ2 method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

79 ASTRONOMY AND ASTROPHYSICS↗

Algae Tile Data: 2004-2007, BPA-51; Preliminary Report, October 28, 2008.

Multiple files containing 2004 through 2007 Tile Chlorophyll data for the Kootenai River sites designated as: KR1, KR2, KR3, KR4 (Downriver) and KR6, KR7, KR9, KR9.1, KR10, KR11, KR12, KR13, KR14 (Upriver) were received by SCS. For a complete description of the sites covered, please refer to http://ktoi.scsnetw.com. To maintain consistency with the previous SCS algae reports, all analyses were carried out separately for the Upriver and Downriver categories, as defined in the aforementioned paragraph. The Upriver designation, however, now includes three additional sites, KR11, KR12, and the nutrient addition site, KR9.1. Summary statistics and information on the four responses, chlorophyll a, chlorophyll a Accrual Rate, Total Chlorophyll, and Total Chlorophyll Accrual Rate are presented in Print Out 2. Computations were carried out separately for each river position (Upriver and Downriver) and year. For example, the Downriver position in 2004 showed an average Chlorophyll a level of 25.5 mg with a standard deviation of 21.4 and minimum and maximum values of 3.1 and 196 mg, respectively. The Upriver data in 2004 showed a lower overall average chlorophyll a level at 2.23 mg with a lower standard deviation (3.6) and minimum and maximum values of (0.13 and 28.7, respectively). A more comprehensive summary of each variable and position is given in Print Out 3. This lists the information above as well as other summary information such as the variance, standard error, various percentiles and extreme values. Using the 2004 Downriver Chlorophyll a as an example again, the variance of this data was 459.3 and the standard error of the mean was 1.55. The median value or 50th percentile was 21.3, meaning 50% of the data fell above and below this value. It should be noted that this value is somewhat different than the mean of 25.5. This is an indication that the frequency distribution of the data is not symmetrical (skewed). The skewness statistic, listed as part of the first section of each analysis, quantifies this. In a symmetric distribution, such as a Normal distribution, the skewness value would be 0. The tile chlorophyll data, however, shows larger values. Chlorophyll a, in the 2004 Downriver example, has a skewness statistic of 3.54, which is quite high. In the last section of the summary analysis, the stem and leaf plot graphically demonstrates the asymmetry, showing most of the data centered around 25 with a large value at 196. The final plot is referred to as a normal probability plot and graphically compares the data to a theoretical normal distribution. For chlorophyll a, the data (asterisks) deviate substantially from the theoretical normal distribution (diagonal reference line of pluses), indicating that the data is non-normal. Other response variables in both the Downriver and Upriver categories also indicated skewed distributions. Because the sample size and mean comparison procedures below require symmetrical, normally distributed data, each response in the data set was logarithmically transformed. The logarithmic transformation, in this case, can help mitigate skewness problems. The summary statistics for the four transformed responses (log-ChlorA, log-TotChlor, and log-accrual ) are given in Print Out 4. For the 2004 Downriver Chlorophyll a data, the logarithmic transformation reduced the skewness value to -0.36 and produced a more bell-shaped symmetric frequency distribution. Similar improvements are shown for the remaining variables and river categories. Hence, all subsequent analyses given below are based on logarithmic transformations of the original responses.

13 HYDRO ENERGY↗

The International Framework for Maintaining Equivalence and Traceability in Radionuclide Metrology

Confidence that a testing or calibration laboratory consistently obtains reliable results is of major importance to users of laboratory services and participation in proficiency testing schemes provides laboratories with an objective means of assessing and demonstrating the level of confidence that can be ascribed to the reliability of the data they are producing. That level of confidence, in turn, depends on the quality of the proficiency tests and, in particular, on the accuracy of the property values associated with the test samples. In the ideal situation, the relevant property value, such as the activity of a particular radionuclide in a test matrix, will be directly traceable to the SI via comparisons with a national or international metrology institute (NMI). This, in turn, begs the question of, how reliable are the results from that NMI.Demonstration of that reliability at the highest metrological levels is achieved through inter-laboratory comparisons that are conducted between national and international metrological institutes. These are coordinated primarily by the Bureau International des Poids et Mesures (BIPM) via Key Comparisons or by comparisons within Regional Metrological Organisations (RMOs), with the results from those RMO exercises being linked to the BIPM Key Comparison results. Such programmes have been in place for many years but they have grown in importance and frequency over the past decade. Tabulation of these comparison data has been regularized recently and made available to the user communities via the BIPM Key Comparison Database (KCDB).In the field of ionizing radiation, the radionuclide metrology discipline exhibits a number of special features. For example, these include the number of potential radionuclides in a user sample; the variety of physical and chemical formats that may be presented; the statistical and temporal effects of radioactive decay; the variations in primary standardization techniques; and the restricted applicability of those primary standardization techniques to the full range of potential radionuclides and activities. Each of these, singly or in combination, ensure that there can never be a fully comprehensive set of Key Comparisons which will cover the requirements of the user community and, in turn, compromise the ability to provide a full range of proficiency tests for testing and calibration laboratories.These problems are discussed, in the context of radioactivity measurements, together with the structure and range of Key Comparisons and associated databases at the highest international level that are currently in place to underpin the proficiency tests that are necessary for the user communities in this field of application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer

Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard χ^(2) method and maximum likelihood based on Poisson (C) statistics. The difference is studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn Kα calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the χ^(2) method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of ∼5 eV and a line with about 100 photons, the line width becomes ∼10% lower in the χ^(2) method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

Shinya Yamada↗

Evaluating Tropical Precipitation Relations in CMIP6 Models with ARM Data

Abstract A set of diagnostics based on simple, statistical relationships between precipitation and the thermodynamic environment in observations is implemented to assess phase 6 of the Coupled Model Intercomparison Project (CMIP6) model behavior with respect to precipitation. Observational data from the Atmospheric Radiation Measurement (ARM) permanent field observational sites are augmented with satellite observations of precipitation and temperature as an observational baseline. A robust relationship across observational datasets between column water vapor (CWV) and precipitation, in which conditionally averaged precipitation exhibits a sharp pickup at some critical CWV value, provides a useful convective onset diagnostic for climate model comparison. While a few models reproduce an appropriate precipitation pickup, most models begin their pickup at too low CWV and the increase in precipitation with increasing CWV is too weak. Convective transition statistics compiled in column relative humidity (CRH) partially compensate for model temperature biases—although imperfectly since the temperature dependence is more complex than that of column saturation. Significant errors remain in individual models and weak pickups are generally not improved. The conditional-average precipitation as a function of CRH can be decomposed into the product of the probability of raining and mean precipitation during raining times (conditional intensity). The pickup behavior is primarily dependent on the probability of raining near the transition and on the conditional intensity at higher CRH. Most models roughly capture the CRH dependence of these two factors. However, compensating biases often occur: model conditional intensity that is too low at a given CRH is compensated in part by excessive probability of precipitation.

54 ENVIRONMENTAL SCIENCES↗

SU-F-BRD-02: Application of ARCHERRT-- A GPU-Based Monte Carlo Dose Engine for Radiation Therapy -- to Tomotherapy and Patient-Independent IMRT

Purpose: As a module of ARCHER -- Accelerated Radiation-transport Computations in Heterogeneous EnviRonments, ARCHER{sub RT} is designed for RadioTherapy (RT) dose calculation. This paper describes the application of ARCHERRT on patient-dependent TomoTherapy and patient-independent IMRT. It also conducts a 'fair' comparison of different GPUs and multicore CPU. Methods: The source input used for patient-dependent TomoTherapy is phase space file (PSF) generated from optimized plan. For patient-independent IMRT, the open filed PSF is used for different cases. The intensity modulation is simulated by fluence map. The GEANT4 code is used as benchmark. DVH and gamma index test are employed to evaluate the accuracy of ARCHER{sub RT} code. Some previous studies reported misleading speedups by comparing GPU code with serial CPU code. To perform a fairer comparison, we write multi-thread code with OpenMP to fully exploit computing potential of CPU. The hardware involved in this study are a 6-core Intel E5-2620 CPU and 6 NVIDIA M2090 GPUs, a K20 GPU and a K40 GPU. Results: Dosimetric results from ARCHER{sub RT} and GEANT4 show good agreement. The 2%/2mm gamma test pass rates for different clinical cases are 97.2% to 99.7%. A single M2090 GPU needs 50~79 seconds for the simulation to achieve a statistical error of 1% in the PTV. The K40 card is about 1.7∼1.8 times faster than M2090 card. Using 6 M2090 card, the simulation can be finished in about 10 seconds. For comparison, Intel E5-2620 needs 507∼879 seconds for the same simulation. Conclusion: We successfully applied ARCHER{sub RT} to Tomotherapy and patient-independent IMRT, and conducted a fair comparison between GPU and CPU performance. The ARCHER{sub RT} code is both accurate and efficient and may be used towards clinical applications.

60 APPLIED LIFE SCIENCES↗

Statistical estimation of the quality of quantum-tomography protocols

We present a complete methodology for testing the performances of quantum tomography protocols. The theory is validated by several numerical examples and by the comparison with experimental results achieved with various protocols for whole families of polarization states of qubits and ququarts including pure, mixed, entangled, and separable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lagrangian and Eulerian statistics obtained from direct numerical simulations of homogeneous turbulence

Direct numerical simulation is used to study dispersion in decaying isotropic turbulence and homogeneous shear flow. Both Lagrangian and Eulerian data are presented allowing direct comparison, but at fairly low Reynolds number. The quantities presented include properties of the dispersion tensor, isoprobability contours of particle displacement, Lagrangian and Eulerian velocity autocorrelations and time scale ratios, and the eddy diffusivity tensor. The Lagrangian time microscale is found to be consistently larger than the Eulerian microscale, presumably due to the advection of the small scales by the large scales in the Eulerian reference frame.

Squires, Kyle D.↗

Machine Learning Inference of Random Medium Properties

Earth materials are heterogeneous across a range of spatial scales, but the resolvability of small structures is limited by sparse data coverage, noise, bandlimitedness, and other difficulties. In practice, heterogeneities below a certain size cannot be recovered from seismic data except through statistical medium descriptions, which even then can be difficult to uniquely determine. To improve the characterization of such heterogeneities, we develop a novel supervised machine learning (ML) model that provides insight about the recoverability of statistical medium properties from elastic waveform data and succeeds despite cycle-skipping and other challenges well known from elastic waveform inversion. We demonstrate the approach using random media generated by superimposing self-affine random variations on homogeneous and layered background structures. After training on sparsely-recorded, high-frequency waveforms from hundreds of different random medium realizations, we show the ability of our ML model to recover correlation lengths and other statistical properties of interest to near-surface and crustal seismology, among other fields. For frequency passbands and spatial offsets encountered in seismology, Gaussian correlation lengths and the amplitude of the random variations relative to the background model are recovered even in challenging scenarios involving unknown medium parameters, complex crustal structures, and low signal-to-noise ratio. In comparison, von Kármán correlation lengths, which are related to larger-wavelength variations of the medium than Gaussian correlation lengths, are not as well recovered. These results provide one of the first and most systematic investigations of the recoverability of statistical properties of heterogeneities below the resolution limit of deterministic seismic tomography, and suggest practical ML strategies for high-frequency waveform seismology.

58 GEOSCIENCES↗

A particle-in-cell code comparison for ion acceleration: EPOCH, LSP, and WarpX

There are now more Particle-in-Cell (PIC) codes than ever before that researchers use to simulate intense laser-plasma interactions. To date, there have been relatively few direct comparisons of these codes in the literature, especially for relativistic intensity lasers interacting with thin overdense targets. To address this we perform a code comparison of three PIC codes: EPOCH, LSP, and WarpX for the problem of laser-driven ion acceleration in a 2D(3v) geometry for a 10 20 W cm -2 intensity laser. We examine the plasma density, ion energy spectra, and laser-plasma coupling of the three codes and find strong agreement. We also run the same simulation 20 times with different random seeds to explore statistical fluctuations of the outputs. We then compare the execution times and memory usage of the codes (without “tuning” to improve performance) using between 1 and 48 processors on one node. We provide input files to encourage larger and more frequent code comparisons in this field.

36 MATERIALS SCIENCE↗

The retailed gasoline price in China: Time-series analysis and future trend projection

This study introduces a method to systematically project retailed gasoline prices in China and provides projection results. Based on oil taxation and pricing mechanisms in China, this study establishes the statistical relationship between the retailed gasoline prices in China and international crude oil prices using error correction models (ECM), time-series models. Detailed comparison among asymmetric ECM, threshold ECM, and threshold asymmetric ECM are provided. By adopting the ECMs, the study projects the retailed gasoline prices from 2019 to 2050 based on the international crude oil prices from the Annual Energy Outlook provided by the U.S. Energy Information Administration. The results show that the asymmetric responsiveness and the threshold effect exist under current Chinese oil pricing policy with a lag of one month or even shorter in gasoline price adjustment. Moreover, the analysis informs one that, in the short-run, the retailed gasoline prices in China are more sensitive to international crude oil price increases; while in the long-run, the retailed gasoline prices are more sensitive to international crude oil price decreases. Compared with the national average gasoline price in China of 6.04 CNY/Liter in 2017, the national average gasoline price in China is projected to be about 7.64 CNY/Liter (2017 dollar) by 2050.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Image-Based 3D Treatment Planning for Vaginal Cylinder Brachytherapy: Dosimetric Effects of Bladder Filling on Organs at Risk

Purpose: To investigate the dosimetric effects of bladder filling on organs at risk (OARs) using three-dimensional image-based treatment planning for vaginal cylinder brachytherapy. Methods and Materials: Twelve patients with endometrial or cervical cancer underwent postoperative high-dose rate vaginal cylinder brachytherapy. For three-dimensional planning, patients were simulated by computed tomography with an indwelling catheter in place (empty bladder) and with 180 mL of sterile water instilled into the bladder (full bladder). The bladder, rectum, sigmoid, and small bowel (OARs) were contoured, and a prescription dose was generated for 10 to 35 Gy in 2 to 5 fractions at the surface or at 5 mm depth. For each OAR, the volume dose was defined by use of two different criteria: the minimum dose value in a 2.0-cc volume receiving the highest dose (D{sub 2cc}) and the dose received by 50% of the OAR volume (D{sub 50%}). International Commission on Radiation Units and Measurements (ICRU) bladder and rectum point doses were calculated for comparison. The cylinder-to-bowel distance was measured using the shortest distance from the cylinder apex to the contoured sigmoid or small bowel. Statistical analyses were performed with paired t tests. Results: Mean bladder and rectum D{sub 2cc} values were lower than their respective ICRU doses. However, differences between D{sub 2cc} and ICRU doses were small. Empty vs. full bladder did not significantly affect the mean cylinder-to-bowel distance (0.72 vs. 0.92 cm, p = 0.08). In contrast, bladder distention had appreciable effects on bladder and small bowel volume dosimetry. With a full bladder, the mean small bowel D{sub 2cc} significantly decreased from 677 to 408 cGy (p = 0.004); the mean bladder D{sub 2cc} did not increase significantly (1,179 cGy vs. 1,246 cGy, p = 0.11). Bladder distention decreased the mean D{sub 50%} for both the bladder (441 vs. 279 cGy, p = 0.001) and the small bowel (168 vs. 132 cGy, p = 0.001). Rectum and sigmoid volume doses were not affected by bladder filling. Conclusions: In high-dose rate vaginal cylinder brachytherapy, treatment with a distended bladder preferentially reduces high dose to the small bowel around the vaginal cuff without a significant change in dose to the bladder, rectum, or sigmoid.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrieval of Aerosol Optical Depth in Vicinity of Broken Clouds from Reflectance Ratios: Sensitivity Study

We conducted a sensitivity study to better understand the potential of a new method for retrieving aerosol optical depth (AOD) under partly cloudy conditions. This method exploits reflectance ratios in the visible spectral range and provides an effective way to avoid three-dimensional (3D) cloud effects. The sensitivity study is performed for different observational conditions and random errors in input data. The results of the sensitivity study suggest that this ratio method has the ability to detect clear pixels even in close proximity to clouds. Such detection does not require a statistical analysis of the two-dimensional (2D) horizontal distribution of reflected solar radiation, and thus it could be customized for operational retrievals. In comparison with previously suggested approaches, the ratio method has the capability to increase the "harvest" of clear pixels. Similar to the traditional Independent Pixel Approximation (IPA), the ratio method has a low computational cost for retrieving AOD. In contrast to the IPA method, the ratio method provides much more accurate estimations of the AOD values under broken cloud conditions: pixel-based and domain-averaged estimations of errors in AOD are about 25% and 10%, respectively. Finally, both the ratio-based cloud screening and the accuracy of domain-averaged ratio-based AOD values do not suffer greatly when 5% random errors are introduced in the reflectances.

54 ENVIRONMENTAL SCIENCES↗

Ex Machina Determination of Structural Correlation Functions

Determining the structural properties of condensed-phase systems is a fundamental problem in theoretical statistical mechanics. In this study, we present a machine learning method that is able to predict structural correlation functions with significantly improved accuracy in comparison with traditional approaches. The usefulness of this ex machina (from the machine) approach is illustrated by predicting the radial distribution functions of two paradigmatic condensed-phase systems, a Lennard-Jones fluid and a hard-sphere fluid, and then comparing those results to the results obtained using both integral equation methods and empirically motivated analytical functions. We find that application of the developed ex machina method typically decreases the predictive error by more than an order of magnitude in comparison with traditional theoretical methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗