Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Radon emanation based material measurement and selection for the SuperNEMO double beta experiment

The SuperNEMO Demonstrator experiment aims to study the neutrinoless double beta decay of 7 kg of {sup 82}Se in order to reach a limit on the light Majorana neutrino mass mechanism T{sub 1/2} (ββ0ν) > 6.5 10{sup 24} years (90%CL) equivalent to a mass sensitivity mβ{sub β} < 0.20 - 0.40 eV (90%CL) in two years of data taking. The detector construction started in 2014 and its installation in the Laboratoire Souterrain de Modane (LSM) is expected during the course of 2015. The remaining level of {sup 226}Ra ({sup 238}U chain) in the detector components can lead to the emanation of {sup 222}Rn gas. This isotope should be controlled and reduced down to the level of a 150 µBq/m{sup 3} in the tracker chamber of the detector to achieve the physics goals. Besides the HPGe selection of the detector materials for their radiopurity, the most critical materials have been tested and selected in a dedicated setup facility able to measure their {sup 222}Rn emanation level. The operating principle relies on a large emanation tank (0.7m{sup 3}) that allows measuring large material surfaces or large number of construction pieces. The emanation tank is coupled to an electrostatic detector equipped with a silicon diode to perform the alpha spectroscopy of the gas it contains and extract the {sup 222}Rn daughters. The transfer efficiency and the detector efficiency have been carefully calibrated through different methods. The intrinsic background of the system allows one to measure 222Rn activities down to 3 mBq, leading to a typical emanation sensitivity of 20 µBq/m{sup 2}/day for a 30 m{sup 2} surface sample. Several construction materials have been measured and selected, such as nylon and aluminized Mylar films, photomultipliers and tracking of the SuperNEMO Demonstrator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplexed Cancer Biomarker Detection Using Quartz-based Photonic Crystal Surfaces

A photonic crystal (PC) surface is demonstrated as a high-sensitivity platform for detection of a panel of 21 cancer biomarker antigens using a sandwich enzyme-linked immunosorbent assay (ELISA) microarray format. A quartz-based PC structure fabricated by nanoimprint lithography, selected for its low autofluorescence, supports two independent optical resonances that simultaneously enable enhancement of fluorescence detection of biomarkers and label-free quantification of the density of antibody capture spots. A detection instrument is demonstrated that supports fluorescence and label-free imaging modalities, with the ability to optimize the fluorescence enhancement factor on a pixel-by-pixel basis throughout the microarray using an angle-scanning approach for the excitation laser that automatically compensates for variability in surface chemistry density and capture spot density. Measurements show that the angle-scanning illumination approach reduces the coefficient of variation of replicate assays by 20–99% compared to ordinary fluorescence microscopy, thus supporting reduction in limits of detectable biomarker concentration. Using the PC resonance, biomarkers in mixed samples were detectable at the lowest concentrations tested (2.1–41 pg/mL), resulting in a three-log range of quantitative detection.

Huang, Cheng-Sheng↗

Note: A stand on the basis of atomic force microscope to study substrates for imaging optics

A description of a stand based on atomic force microscopy (AFM) for roughness measurements of large optical components with arbitrary surfaces is given. The sample under study is mounted on a uniaxial goniometer which allows the sample to be tilted in the range of ±30°. The inclination enables the local normal along the axis of the probe to be established at any point of the surface under study. A comparison of the results of the measurement of noise and roughness of a flat quartz sample, in the range of spatial frequencies 0.025–70 μm{sup −1}, obtained from “standard” AFM and developed versions is given. Within the experimental error, the measurement results were equivalent. Examples of applications of the stand for the study of substrates for X-ray optics are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on corrosion behaviors of sintered Nd-Fe-B magnets in different environmental conditions

Nd-Fe-B magnets have outstanding magnetic properties, but their corrosion resistance is poor because the rare-earth-rich phases in them are easily oxidized. In this article, we report an investigation of the corrosion behaviors of sintered Nd-Fe-B magnets with varied compositions in different corrosion conditions. The weight losses of the magnets after corrosion testing were measured after brushing off the corrosion products. The magnetic flux losses of the magnets were measured using a fluxmeter. A scanning electron microscope equipped with an energy dispersive x-ray analysis system was employed to observe the corrosion morphology. It was found that the humid-heat resistance of the magnets was obviously improved by partially substituting Dy for Nd and adding minor Co. The corrosion products and morphologies of Nd-Fe-B magnets for the autoclave test were different from those for the constant humid-heat test. The corrosion rates of the magnets for the former were much slower than for the latter; this is probably because the high-pressure steam led to an oxygen-deficient atmosphere, and the liquid film on the surface of the magnet specimens hindered the diffusion of oxygen into the bulk for the autoclave test.

36 MATERIALS SCIENCE↗

Inelastic and Reactive Scattering Dynamics of Hyperthermal Oxygen Atoms on Ionic Liquid Surfaces: [emim][NTf{sub 2}] and [C{sub 12}mim][NTf{sub 2}]

Collisions of hyperthermal oxygen atoms, with an average translational energy of 520 kJ mol{sup -1}, on continuously refreshed ionic liquids, 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide ([emim][NTf{sub 2}]) and 1-dodecyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide ([C{sub 12}mim][NTf{sub 2}]), were studied with the use of a beam-surface scattering technique. Time-of-flight and angular distributions of inelastically scattered O and reactively scattered OH and H{sub 2}O were collected for various angles of incidence with the use of a rotatable mass spectrometer detector. For both O and OH, two distinct scattering processes were identified, which can be empirically categorized as thermal and non-thermal. Non-thermal scattering is more probable for both O and OH products. The observation of OH confirms that at least some reactive sites, presumably alkyl groups, must be exposed at the surface. The ionic liquid with the longer alkyl chain, [C{sub 12}mim][NTf{sub 2}], is substantially more reactive than the liquid with the shorter alkyl chain, [emim][NTf{sub 2}], and proportionately much more so than would be predicted simply from stoichiometry based on the number of abstractable hydrogen atoms. Molecular dynamics models of these surfaces shed light on this change in reactivity. The scattering behavior of O is distinctly different from that of OH. However, no such differences between inelastic and reactive scattering dynamics have been seen in previous work on pure hydrocarbon liquids, in particular the benchmark, partially branched hydrocarbon, squalane (C{sub 30}H{sub 62}). The comparison between inelastic and reactive scattering dynamics indicates that inelastic scattering from the ionic liquid surfaces takes place predominantly at non-reactive sites that are effectively stiffer than the reactive alkyl chains, with a higher proportion of collisions sampling such sites for [emim][NTf{sub 2}] than for [C{sub 12}mim][NTf{sub 2}].

74 ATOMIC AND MOLECULAR PHYSICS↗

Low-Power, Flexible Sensor Arrays with Solderless Board-to-Board Connectors for Monitoring Soil Deformation and Temperature

Landslides are a global and frequent natural hazard, affecting many communities and infrastructure networks. Technological solutions are needed for long-term, large-scale condition monitoring of infrastructure earthworks or natural slopes. However, current instruments for slope stability monitoring are often costly, require a complex installation process and/or data processing schemes, or have poor resolution. Wireless sensor networks comprising low-power, low-cost sensors have been shown to be a crucial part of landslide early warning systems. Here, we present the development of a novel sensing approach that uses linear arrays of three-axis accelerometers for monitoring changes in sensor inclination, and thus the surrounding soil’s deformation. By combining these deformation measurements with depth-resolved temperature measurements, we can link our data to subsurface thermal–hydrological regimes where relevant. In this research, we present a configuration of cascaded I2C sensors that (i) have ultra-low power consumption and (ii) enable an adjustable probe length. From an electromechanical perspective, we developed a novel board-to-board connection method that enables narrow, semi-flexible sensor arrays and a streamlined assembly process. The low-cost connection method relies on a specific FR4 printed circuit board design that allows board-to-board press fitting without using electromechanical components or solder connections. The sensor assembly is placed in a thin, semi-flexible tube (inner diameter 6.35 mm) that is filled with an epoxy compound. The resulting sensor probe is connected to an AA-battery-powered data logger with wireless connectivity. We characterize the system’s electromechanical properties and investigate the accuracy of deformation measurements. Our experiments, performed with probes up to 1.8 m long, demonstrate long-term connector stability, as well as probe mechanical flexibility. Furthermore, our accuracy analysis indicates that deformation measurements can be performed with a 0.390 mm resolution and a 95% confidence interval of ±0.73 mm per meter of probe length. This research shows the suitability of low-cost accelerometer arrays for distributed soil stability monitoring. In comparison with emerging low-cost measurements of surface displacement, our approach provides depth-resolved deformation, which can inform about shallow sliding surfaces.

deformation monitoring↗

Identification Of Rippability And Bedrock Depth Using Seismic Refraction

Spatial variability of the bedrock with reference to the ground surface is vital for many applications in geotechnical engineering to decide the type of foundation of a structure. A study was done within the development area of Mutiara Damansara utilising the seismic refraction method using ABEM MK8 24 channel seismograph. The geological features of the subsurface were investigated and velocities, depth to the underlying layers were determined. The seismic velocities were correlated with rippability characteristics and borehole records. Seismic sections generally show a three layer case. The first layer with velocity 400-600 m/s predominantly consists of soil mix with gravel. The second layer with velocity 1600-2000 m/s is suggested to be saturated and weathered area. Both layers forms an overburden and generally rippable. The third layer represents granite bedrock with average depth and velocity 10-30 m and >3000 m/s respectively and it is non-rippable. Steep slope on the bedrock are probably the results of shear zones.

58 GEOSCIENCES↗

Modification of a commercial cavity ring-down spectroscopy NO{sub 2} detector for enhanced sensitivity

Nitrogen dioxide (NO{sub 2}) plays a central role in atmospheric chemistry, air pollution, and biogeochemical cycles. Many analytical techniques have been developed to detect NO{sub 2}, but only chemiluminescence-based instruments are commonly, commercially available. There remains a need for a fast, light, and simple method to directly measure NO{sub 2}. In this work we describe the modification and characterization of a small, commercially available cavity ring-down spectroscopy (CRDS) NO{sub 2} detector suitable for surface and aircraft monitoring. A metal oxide scrubber was added to remove NO{sub 2}, and provide a chemical zero, improving the detection limit (3{sigma} of the background noise) from several parts per billion by volume (ppbv) to 0.06 ppbv, integrated over 60 s. Known interferences by water and particles were removed using Nafion tubing and a 1 {mu}m Teflon filter, respectively. A 95% response time of 18{+-}1 s was observed for a step change in concentration. The CRDS detector was run in parallel to an ozone chemiluminescence device with photolytic conversion of NO{sub 2} to NO. The two instruments measured ambient air in suburban Maryland. A least-squares fit to the comparison data resulted a slope of 0.960{+-}0.002 and R of 0.995, showing agreement within experimental uncertainty.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Direct measurement of the point-to-point resolution for microns-thick specimens in the ultrahigh-voltage electron microscope

We report on a direct measurement method and results of the point-to-point resolution for microns-thick amorphous specimens in the ultrahigh-voltage electron microscope (ultra-HVEM). We first obtain the ultra-HVEM images of nanometer gold particles with different sizes on the top surfaces of the thick epoxy-resin specimens. Based on the Rayleigh criterion, the point-to-point resolution is then determined as the minimum distance between centers of two resolvable tangent gold particles. Some values of resolution are accordingly acquired for the specimens with different thicknesses at the accelerating voltage of 2 MV, for example, 18.5 nm and 28.4 nm for the 5 {mu}m and 8 {mu}m thick epoxy-resin specimens, respectively. The presented method and results provide a reliable and useful approach to quantifying and comparing the achievable spatial resolution for the thick specimens imaged in the mode of transmission electron including the scanning transmission electron microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined dry plasma etching and online metrology for manufacturing highly focusing x-ray mirrors

A new figuring station was designed and installed at the ESRF beamline BM05. It allows the figuring of mirrors within an iterative process combining the advantage of online metrology with dry etching. The complete process takes place under a vacuum environment to minimize surface contamination while non-contact surfacing tools open up the possibility of performing at-wavelength metrology and eliminating placement errors. The aim is to produce mirrors whose slopes do not deviate from the stigmatic profile by more than 0.1 µrad rms while keeping surface roughness in the acceptable limit of 0.1-0.2 nm rms. The desired elliptical mirror surface shape can be achieved in a few iterations in about a one day time span. This paper describes some of the important aspects of the process regarding both the online metrology and the etching process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Pressure Neutron Diffraction Study on H-D Isotope Effects in Brucite

A neutron powder diffraction study of hydrogenated and deuterated brucite was conducted at ambient temperature and at pressures to 9 GPa, using a Paris-Edinburgh high-pressure cell at the WAND instrument of ORNL High Flux Isotope Reactor. The two materials were synthesized by the same method and companion measurements of neutron diffraction were conducted under the same conditions. Our refinement results show that the lattice-parameters of the a axis, parallel to the sheets of Mg-O octahedra, decreases only slightly with pressure with no effect of H-D substitution. However, the c axis of Mg(OD)2 is shorter and decreases more rapidly than that of Mg(OH)2 with increasing pressure. Consequently, the unit-cell volume of deuterated brucite is slightly, but systematically smaller than that of normal brucite, which were fitted to third-order Birch-Murnaghan equation: K0=41.46 0.52 and 39.04 0.30 GPa for Mg(OH)2 and Mg(OD)2, respectively with a fixed K0 value of 10. Our results suggest that H-D substitution of brucite and other hydrous minerals with H-bonding likely influences their structural and dynamic properties under pressure, including the position of hydrogen atoms. The measured effect of H-D substitution on the unit-cell volume also demonstrates that brucite (and other hydrous minerals) preferentially incorporate deuterium over hydrogen under pressure, suggesting that the distribution of hydrogen isotopes in deep-earth conditions may differ significantly from that in near-surface environments.

08 HYDROGEN↗

Inflow Characterization for Marine and Hydrokinetic Energy Devices. FY-2010 Annual Progress Report

Marine and Hydro Kinetic devices (MHK) are being widely studied as a source of renewable energy. The Marrowstone Island site is a potential location for installing MHK devices because the tidal currents observed that are sufficient for power generation. In order to quantify the effects of turbulence on MHK devices and the surrounding environment at this site, a prelimi- nary fluid flow field study was conducted here by the Pacific Northwest National Lab (PNNL) in collaboration with the Applied Physics Lab at the University of Washington (APL-UW). This study entailed continuous The Acoustic Doppler Velocimetry (ADV), Acoustic Doppler Current Profiler (ADCP) and Conductivity, Temperature and Depth (CTD) measurements from May 4, 2010 to May 22, 2010, in order to obtain information about turbulence effects during different tidal conditions. The instruments used for collecting the above measurements were deployed at the Marrowstone site using a R/V Jack Robertson provided by the University of Washington (APL-UW). All the measurements were taken at the site with an average depth of 22 m below the sea surface. ADV acquired velocity data at 32 Hz sampling frequency at 4.6 m above the seabed, and ADCP acquired velocity profile data at a sampling frequency of 2 Hz, from a height of 2.6 m above the seabed to the surface with a bin resolution of 0.5 m. The ADV and ADCP measurements showed that the horizontal velocity had a turbulence intensity of 10%. Further- more, the spectral analysis from ADV measurements showed that the flow is fully turbulent with -5/3 slope in the inertial sub-range of the spectra. Moreover, the temporal-frequency analysis showed presence of ”eddies” at high frequencies. These preliminary studies provided initial flow field and site characteristics, showed the limitations of the instruments used and highlighted changes that need to be made in the experimental setup for deployment in FY-2011 studies.

13 HYDRO ENERGY↗

Reference surface excess isotherms for carbon dioxide adsorption on ammonium ZSM-5 at various temperatures

Abstract This work is part of the effort at the Facility for Adsorbent Characterization and Testing (FACT lab) at the National Institute of Standards and Technology (NIST) to develop reference materials, reference data, and measurement best practices for adsorption metrology. High-pressure surface excess isotherms for CO 2 adsorption on NIST Reference Material 8852 (ammonium ZSM-5) at 15 °C, 25 °C, and 35 °C are reported, expanding on a FACT Lab-organized international interlaboratory study on this sorbent/sorbate pair at 20 °C. The range of temperatures of the present study is of interest for many CO 2 adsorption measurements and applications. Measurements were made using five different adsorption instruments, both manometric and gravimetric. Excellent agreement in the measured isotherms among the instruments was found. An empirical reference equation of the form, $${n}_{ex,ref}({P}_{eq})=\frac{c}{\{{1+\mathrm{exp}[\left(-\mathrm{ln}\left(P\right)+a\right)/b ]\}}^{b }} ,$$ n e x , r e f ( P eq ) = c { 1 + exp [ - ln P + a / b ] } b , [ n ex,ref is surface excess uptake (mmol/g); P eq is equilibrium pressure (MPa); P is ( P eq )/(1 MPa)]; a , b , c are constants] and the 95% uncertainty interval were determined for the isotherms at each of the temperatures. Lastly, the isosteric heat of adsorption is estimated from absolute isotherms derived from the surface excess reference data.

Nguyen, Huong Giang T. (ORCID:0000000210527565)↗

Development and calibration of a Thomson parabola with microchannel plate for the detection of laser-accelerated MeV ions

This article reports on the development and application of a Thomson parabola (TP) equipped with a (90x70) mm{sup 2} microchannel-plate (MCP) for the analysis of laser-accelerated ions, produced by a high-energy, high-intensity laser system. The MCP allows an online measurement of the produced ions in every single laser shot. An electromagnet instead of permanent magnets is used that allows the tuning of the magnetic field to adapt the field strength to the analyzed ion species and energy. We describe recent experiments at the 100 TW laser facility at the Laboratoire d'Utilization des Lasers Intenses (LULI) in Palaiseau, France, where we have observed multiple ion species and charge states with ions accelerated up to 5 MeV/u (O{sup +6}), emitted from the rear surface of a laser-irradiated 50 {mu}m Au foil. Within the experiment the TP was calibrated for protons and for the first time conversion efficiencies of MeV protons (2-13 MeV) to primary electrons (electrons immediately generated by an ion impact onto a surface) in the MCP are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of electroless nickel-phosphorus plating for ultracold-neutron storage

Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of 2.8 • 10 -4 to 4.1 • 10 -4 for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential η of 1.7 • 10 -4 to 3.3 • 10 -4 . Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. In conclusion, based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with η = 3.5(5)•10 -4 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of photon Doppler velocimetry to direct impact Hopkinson pressure bars

Direct impact Hopkinson pressure bar systems offer many potential advantages over split Hopkinson pressure bars, including access to higher strain rates, higher strains for equivalent striker velocity and system length, lower dispersion, and faster achievement of force equilibrium. Currently, these advantages are gained at the expense of all information about the striker impacted specimen face, preventing the experimental determination of force equilibrium, and requiring approximations to be made on the sample deformation history. In this paper, we discuss an experimental method and complementary data analysis for using photon Doppler velocimetry to measure surface velocities of the striker and output bars in a direct impact bar experiment, allowing similar data to be recorded as in a split bar system. We discuss extracting velocity and force measurements, and the precision of measurements. Results obtained using the technique are compared to equivalent split bar tests, showing improved stress measurements for the lowest and highest strains in fully dense metals, and improvement for all strains in slow and non-equilibrating materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing nanoscale scanning probes using electron microscopy: A novel fixture and a practical guide

The nanoscale geometry of probe tips used for atomic force microscopy (AFM) measurements determines the lateral resolution, contributes to the strength of the tip-surface interaction, and can be a significant source of uncertainty in the quantitative analysis of results. While inverse imaging of the probe tip has been used successfully to determine probe tip geometry, direct observation of the tip profile using electron microscopy (EM) confers several advantages: it provides direct (rather than indirect) imaging, requires fewer algorithmic parameters, and does not require bringing the tip into contact with a sample. In the past, EM-based observation of the probe tip has been achieved using ad hoc mounting methods that are constrained by low throughput, the risk of contamination, and repeatability issues. We report on a probe fixture designed for use in a commercial transmission electron microscope that enables repeatable mounting of multiple AFM probes as well as a reference grid for beam alignment. This communication describes the design, fabrication, and advantages of this probe fixture, including full technical drawings for machining. Further, best practices are discussed for repeatable, non-destructive probe imaging. Finally, examples of the fixture’s use are described, including characterization of common commercial AFM probes in their out-of-the-box condition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AN EFFICIENT, COMPACT, AND VERSATILE FIBER DOUBLE SCRAMBLER FOR HIGH PRECISION RADIAL VELOCITY INSTRUMENTS

We present the design and test results of a compact optical fiber double-scrambler for high-resolution Doppler radial velocity instruments. This device consists of a single optic: a high-index n ∼ 2 ball lens that exchanges the near and far fields between two fibers. When used in conjunction with octagonal fibers, this device yields very high scrambling gains (SGs) and greatly desensitizes the fiber output from any input illumination variations, thereby stabilizing the instrument profile of the spectrograph and improving the Doppler measurement precision. The system is also highly insensitive to input pupil variations, isolating the spectrograph from telescope illumination variations and seeing changes. By selecting the appropriate glass and lens diameter the highest efficiency is achieved when the fibers are practically in contact with the lens surface, greatly simplifying the alignment process when compared to classical double-scrambler systems. This prototype double-scrambler has demonstrated significant performance gains over previous systems, achieving SGs in excess of 10,000 with a throughput of ∼87% using uncoated Polymicro octagonal fibers. Adding a circular fiber to the fiber train further increases the SG to >20,000, limited by laboratory measurement error. While this fiber system is designed for the Habitable-zone Planet Finder spectrograph, it is more generally applicable to other instruments in the visible and near-infrared. Given the simplicity and low cost, this fiber scrambler could also easily be multiplexed for large multi-object instruments.

79 ASTRONOMY AND ASTROPHYSICS↗