Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Flight Deck Design of a Hybrid Turbine/Electric Passenger Aircraft

NASA is exploring the development of a 180-passenger subsonic single engine aft turbine aircraft, The aft turbine provides electric power in a hybrid design to wing mounted electric engines, creating a highly efficient, high-bypass-ratio fan equivalent. The SUbsonic Single Aft eNgine (SUSAN) aircraft is being developed as a sustainable subsonic regional aircraft that seeks to reduce emission levels by 50% in the next few decades. Pilot-in-the-loop studies were conducted at the NASA Langley Research Center in Hampton, Virginia, to explore the flight deck design for the hybrid electric aircraft. Following modern trends in commercial aircraft flight decks with full time augmented controls and a quiet and dark philosophy, single throttle and simplified engine displays were developed for the SUSAN aircraft. The aircraft includes a single aft mounted turbine engine and 16 wing mounted electric fans. The final design was developed from feedback received during an earlier pilot-in-the-loop study where one, two, and three throttles were tested in standard airline operations, including various failures of the turbine and electric engines. Current flight deck designs normally provide control inceptors for each propulsion engine and an engine display for all primary aircraft engine parameters. With full time augmentation expected, a single throttle control with autothrottle always engaged, even during failures, is desired. Augmentation of flight controls using distributed thrust also requires full time control of the electric engines using automation. Additionally, electric engine thrust is augmented during climb based on battery state of charge. Thrust augmentation changes faster than human reaction time and therefore requires full-time automation. A pilot-in-the-loop study was conducted at the NASA Langley Research Center in Hampton, Virginia, to test the final design of the single throttle with simplified engine displays. Fourteen airline pilots evaluated the single throttle and engine display concept. Electric engine failures included one, four symmetric, and eight non-symmetric electric engine failures. The turbine engine was evaluated for complete and partial failure during critical phases of flight to include takeoff as well as enroute. Unexpected go-arounds increase workload and require significant throttle manipulation. Go-arounds were included to ensure the single throttle was usable for all phases of flight. Failures during takeoff required a return to the departure field and failures enroute required a diversion except for one and four electric engine failures as these failures did not affect aircraft flyability or range. There are currently no Part 25 aircraft certified with hybrid systems or electric engines with batteries as emergency propulsion. For turbine engine failures in the SUSAN aircraft design, range is limited to 30 minutes at full power. Battery state of charge and battery health displays were developed and tested for usability and to determine how well they supported pilot decisions for alternate airports during emergency diversions. Novel displays using shape and color were developed to provide immediate feedback when state of charge became critical. This paper details the pilot study including pilot feedback supporting the potential for increased automation and a single throttle control. Detailed recommendations are provided for a novel single throttle control and additional pilot controls to support selection of engines during start, shutdown, and engine troubleshooting procedures. This design deviates significantly from current practice of providing throttles for each propulsion engine. Engine display recommendations are provided based on pilot feedback during a guided post-evaluation interview. Battery state of charge and battery health display recommendations were collected from all airline crews. The simplified engine displays design was rated excellent as measured with a usability scale. Quantitative metrics include airspeed tracking, time to complete checklists, time to make diversion decisions and the quality of the diversion decision. Recommendations for future studies are documented with supporting research and current observations about upcoming flight deck certifications.

autothrottle↗

Flat-Plate Solar-Collector Performance Evaluation with a Solar Simulator as a Basis for Collector Selection and Performance Prediction

The use of a solar simulator for performance determination permits collector testing under standard conditions of wind, ambient temperature, flow rate and sun. The performance results determined with the simulator have been found to be in good agreement with outdoor performance results. The measured thermal efficiency and evaluation of 23 collectors are reported which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, antireflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors were given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance was made possible by tests at different incident angles. The solar performance rankings were made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗

Content Addition and Testing for 2017 NRC Amendment for the Versa-Pac Type A Fissile Packaging - 18120

The Versa-Pac is a certified Type A, fissile packaging (USA NRC Certificate no. USA/9342/AF-96), often used as a waste package for one time use. Continuous content additions have improved the versatility of the package resulting in expanded uses for the nuclear industry. Principal design of the Versa-Pac packaging maintains the use of an inner liner positioned inside a 55-gallon (VP-55) or 110-gallon drum (VP-110), as used for decades in the transport and disposal of Type A fissile materials. The Versa-Pac is used directly or in conjunction with pails, pipe containers, poly bottles, and a variety of smaller containers, inserts and vessels. The Versa-Pac content developments assist the industry with site shutdown, decommissioning, and cleanup operations, allowing for removal, transport, and storage options for the residual waste materials. A 2017 NRC license amendment application adds new capabilities to the Versa-Pac that include a low 1.25 wt% {sup 235}U enriched uranium loading, small quantities of UF{sub 6} in the form of 1S and 2S cylinders, and a payload mass increase from 250 to 350 pounds for the Versa-Pac 55-gallon version (VP-55). The lower uranium enrichment loading of 1.25 wt% {sup 235}U allows for a higher uranium mass limit. The inclusion of 1S and 2S UF{sub 6} cylinders fills an industry need to remove and dispose of long-stored material during site cleanup activities. The content payload mass limit is increased for low contaminated or radioactive heavy metal contents, such as cut plant components and ingots. Regulatory certification of new contents is demonstrated by test, analysis, and a combination of these techniques to show that the design function of the Versa-Pac as a Type A fissile package remains unchanged. Specific UF{sub 6} criticality and thermal analysis upgrades are added to the design documentation to accommodate 1S and 2S UF{sub 6} cylinders. The parameters for criticality analyses are simplified, ensuring no credit for cylinder containment is required for HAC thus reducing the reliance on a single specific shoring device. An upgrade of the Versa-Pac thermal analysis demonstrates compliance with ANSI N14.1 UF{sub 6} cylinder thermal limits. A new drop test sequence for the VP-55 was performed, documenting the addition of the 350-pound payload and demonstrating the VP-55 maintains structural integrity during the NCT and HAC drop, crush and puncture events as defined by 10 CFR 71. The testing and analyses show no loss of the material occurs and the package maintains the material in a subcritical state. This paper traces the engineering and licensing efforts involved in expanding the Versa-Pac's versatility for the 2017 NRC amendment application; summarizing the new testing and results for the payload increase, the content addition criticality and thermal evaluations, and content description for the Versa-Pac Safety Analysis Report. The NRC license amendment is scheduled for Winter 2017. Testing and supporting analyses reported in the Versa-Pac Safety Analysis Report demonstrates the content developments met the performance requirements of 10 CFR 71 for a Type A fissile package. A revision of the NRC Certificate of Compliance is expected in Spring 2018. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The COHERENT Experiment at the Spallation Neutron Source

The COHERENT collaboration's primary objective is to measure coherent elastic neutrino- nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils which are out of reach for standard neutrino detectors. The measurement of CEvNS has now become feasible, thanks to the development of ultra-sensitive technology for rare decay and weakly-interacting massive particle (dark matter) searches. The CEvNS cross section is cleanly predicted in the standard model; hence its measurement provides a standard model test. It is relevant for supernova physics and supernova-neutrino detection, and enables validation of dark-matter detector background and detector-response models. In the long term, precision measurement of CEvNS will address questions of nuclear structure. COHERENT will deploy multiple detector technologies in a phased approach: a 14-kg CsI[Na] scintillating crystal, 15 kg of p-type point-contact germanium detectors, and 100 kg of liquid xenon in a two-phase time projection chamber. Following an extensive background measurement campaign, a location in the SNS basement has proven to be neutron-quiet and suitable for deployment of the COHERENT detector suite. The simultaneous deployment of the three COHERENT detector subsystems will test the N=2 dependence of the cross section and ensure an unambiguous discovery of CEvNS. This document describes concisely the COHERENT physics motivations, sensitivity and plans for measurements at the SNS to be accomplished on a four-year timescale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The leading hadronic vacuum polarisation on the lattice

After discussing the relevance of a first principles theory-prediction of the hadronic vacuum polarisation for Standard Model tests, the theoretical challenges for its computation in lattice QCD are reviewed. New ideas that will potentially improve the quality of lattice simulations will be introduced and the status of ongoing simulations will be presented briefly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving air leakage prediction of buildings using the fan pressurization method with the Weighted Line of Organic Correlation

In many countries, the fan pressurization method is the most frequently chosen approach for measuring the air leakage of houses. The measurements are usually performed at pressures that far exceed pressures to which buildings are exposed to under normal conditions. A fit of these tests to the power-law formulation allows an extrapolation to data points outside the measured pressure range. With the Ordinary Least Square (OLS) fitting method, the pressure exponent and flow coefficient can be determined. However, the measurement results are highly sensitive to uncertainties induced by external factors like changing wind conditions during the tests, which is neglected by OLS. This may lead to errors in the prediction of flows at lower pressures. The Weighted Line of Organic Correlation (WLOC) is an alternative approach and takes measurement uncertainty into account. In this paper, a statistical analysis of an extensive data set of pressurization measurements has been performed. Both regression techniques have been compared for almost 7500 fan pressurization measurements of six houses in 109 different house leak configurations. The variability in predicting pressure exponent and flow coefficient for both WLOC and OLS regression was analyzed using probability density functions. It was found that the Weighted Line of Organic Correlation significantly decreases the uncertainty in predicting pressure exponent, flow coefficient, and other low-pressure air leakage metrics compared to the Ordinary Least Square fitting. Here, the authors highly recommend the implementation of WLOC in current measurement standards and test equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dexterity test data contribute to proper glovebox over-glove use

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). The glovebox gloves are the weakest part of this engineering control. The Glovebox Glove Integrity Program, which controls glovebox gloves from procurement to disposal at TA-55, manages this vulnerability. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Proper selection of over-gloves is one of these measures. Line management owning glovebox processes have the responsibility to approve the appropriate personal protective equipment/glovebox glove/over-glove combination. As low as reasonably achievable (ALARA) considerations to prevent unplanned glovebox glove openings must be balanced with glove durability and worker dexterity, both of which affect the final overall risk to the worker. In this study, the causes of unplanned glovebox glove openings, the benefits of over-glove features, the effect of over-gloves on task performance using standard dexterity tests, the pollution prevention benefits, and the recommended over-gloves for a task are presented.

57↗

Investigation of the Semicoa 2N7616 and 2N7425 and the Microsemi 2N7480 for Single-Event Gate Rupture and Single-Event Burnout

Single-event-effect test results for hi-rel total-dose-hardened power MOSFETs are presented in this report. The 2N7616 and the 2N7425 from Semicoa and the 2N7480 from International Rectifier were tested to NASA test condition standards and requirements. The 2N7480 performed well and the data agree with the manufacture's data. The 2N7616 and 2N7425 were entry parts from Semicoa using a new device architecture. Unfortunately, the device performed poorly and Semicoa is withdrawing power MOSFETs from it line due to these data. Vertical metal-oxide-semiconductor field-effect transistors (MOSFETs) are the most commonly used power transistor. MOSFETs are typically employed in power supplies and high current switching applications. Due to the inherent high electric fields in the device, power MOSFETs are sensitive to heavy ion irradiation and can fail catastrophically as a result of single-event gate rupture (SEGR) or single-event burnout (SEB). Manufacturers have designed radiation-hardened power MOSFETs for space applications. See [1] through [5] for more information. The objective of this effort was to investigate the SEGR and SEB responses of two power MOSFETs recently produced. These tests will serve as a limited verification of these parts. It is acknowledged that further testing on the respective parts may be needed for some mission profiles.

Scheick, Leif↗

Subtask 3.11 - Production of CBTL-Based Jet Fuels from Biomass-Based Feedstocks and Montana Coal

The Energy & Environmental Research Center (EERC), in partnership with the U.S. Department of Energy (DOE) and Accelergy Corporation, an advanced fuels developer with technologies exclusively licensed from Exxon Mobil, undertook Subtask 3.11 to use a recently installed bench-scale direct coal liquefaction (DCL) system capable of converting 45 pounds/hour of pulverized, dried coal to a liquid suitable for upgrading to fuels and/or chemicals. The process involves liquefaction of Rosebud mine coal (Montana coal) coupled with an upgrading scheme to produce a naphthenic fuel. The upgrading comprises catalytic hydrotreating and saturation to produce naphthenic fuel. A synthetic jet fuel was prepared by blending equal volumes of naphthenic fuel with similar aliphatic fuel derived from biomass and 11 volume % of aromatic hydrocarbons. The synthetic fuel was tested using standard ASTM International techniques to determine compliance with JP-8 fuel. The composite fuel thus produced not only meets but exceeds the military aviation fuel-screening criteria. A 500-milliliter synthetic jet fuel sample which met internal screening criteria was submitted to the Air Force Research Laboratory (AFRL) at Wright–Patterson Air Force Base, Dayton, Ohio, for evaluation. The sample was confirmed by AFRL to be in compliance with U.S. Air Force-prescribed alternative aviation fuel initial screening criteria. The results show that this fuel meets or exceeds the key specification parameters for JP-8, a petroleum-based jet fuel widely used by the U.S. military. JP-8 specifications include parameters such as freeze point, density, flash point, and others; all of which were met by the EERC fuel sample. The fuel also exceeds the thermal stability specification of JP-8 fuel as determined by the quartz crystalline microbalance (QCM) test also performed at an independent laboratory as well as AFRL. This means that the EERC fuel looks and acts identically to petroleum-derived jet fuel and can be used interchangeably without any special requirements and thus provides a pathway to energy security to the U.S. military and the entire nation. This subtask was funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26- 08NT43291. Nonfederal funding was provided by Accelergy Corporation.

Sharma, Ramesh↗

Physics Prospects for a near-term Proton-Proton Collider

Hadron colliders at the energy frontier offer significant discovery potential through precise measurements of Standard Model processes and direct searches for new particles and interactions. A future hadron collider would enhance the exploration of particle physics at the electroweak scale and beyond, potentially uniting the community around a common project. The LHC has already demonstrated precision measurement and new physics search capabilities well beyond its original design goals and the HL-LHC will continue to usher in new advancements. This document highlights the physics potential of an FCC-hh machine to directly follow the HL-LHC. In order to reduce the timeline and costs, the physics impact of lower collider energies, down to $\sim 50$~TeV, is evaluated. Lower centre-of-mass energy could leverage advanced magnet technology to reduce both the cost and time to the next hadron collider. Such a machine offers a breadth of physics potential and would make key advancements in Higgs measurements, direct particle production searches, and high-energy tests of Standard Model processes. Most projected results from such a hadron-hadron collider are superior to or competitive with other proposed accelerator projects and this option offers unparalleled physics breadth. The FCC program should lay out a decision-making process that evaluates in detail options for proceeding directly to a hadron collider, including the possibility of reducing energy targets and staging the magnet installation to spread out the cost profile.

FOS: Physical sciences↗

Electric Plasma Arc-Lamp Combustor Liner Durability Test System Developed

Silicon carbide matrix composites are candidate materials for high-temperature combustor liners. Because through-the-thickness thermal gradients are the primary cause of stress on combustor liners, a unique test facility was developed at the NASA Glenn Research Center at Lewis Field to simulate in-service pure thermal stress distributions in fiber reinforced silicon carbide cylinders. It was developed initially under Phase II of the High- Speed Research Program. This test stand can accommodate 8-in.-long test cylinders that have outer diameters of 4 in. and a wall thickness of about 0.08 to 0.12 in. One cylinder at a time is loaded vertically into the test stand. Water-cooled plates enclose the open ends of the cylinder and provide cooling. Load plates on the exterior side of the water-cooled plates provide support and compression loads. To evaluate a combustor liner material s potential performance, researchers induce thermal gradients with an axisymmetric, direct-current, electric arc within the cylinder while refrigerated air at a rate of 1.5 lb/sec impinges on the outside surface of the cylinder. The achievable through-the-thickness thermal gradient is predicted to be in excess of 200 C. The 8-in. long, 0.5-in.-diameter plasma arc emits full spectrum visible light; radiant intensity exceeds 300 Watts per square centimeters to produce temperatures in excess of 1500 C on materials with emissivity near unity. Because the system does not rely upon the combustion of fuels to achieve the related thermal conditions, ancillary environmental reactions with the sample are eliminated. The system incorporates a standard mechanical test frame, which can impose constant as well cyclical axial stresses up to 2200 lb upon the test piece. Silicon-carbide-fiber reinforced silicon carbide matrix composite cylinders were instrumented with thin-film thermocouples to obtain through-the-thickness thermal flux measurements. Inside wall temperatures reached 1200 C with only 250 A of current. One of the special features of this configuration is the creation of hoop stress states within the cylinder, which up this point have not been obtainable in planar coupon tests. This facility will allow various operational modes, including accelerated tests of thermal transients simulating the effects of repeated engine ignition as well as prescribed thermal and mechanical histories to simulate various duty cycle profiles. Tests can now be performed on thermal-barrier-coated metallic liners and ceramic composite liners that require a combination of high heat flux and controlled mechanical stresses.

Goldsby, Jon C.↗

Experimental Measurement of Low Energy Neutrino Interactions

Neutrino interactions in the few to few tens of MeV range are of importance for several physics topics, including solar, supernova and reactor neutrinos, as well as future proposed oscillation and Standard Model test experiments. Although interaction cross-sections for some simple targets are well understood, very little experimental data exist for interactions with nuclei. This talk will discuss the motivation for measuring low energy neutrino interactions, the state of knowledge, and possible future strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-556: A Potential Real Time AQA for Cyberknife Cones and MLC Based Treatments

Purpose: To investigate the potential use of the Raven™ (LAP of America Laser Applications) for real time AQA of Cyberknife™ with InCise2 MLC (Accuray™ Medical). Methods: At setup, the Raven was rotated 45° on which an Accuray™ AQA cube was positioned. Three different AQA plans for fixed cone, InCise2MLC, and a modified MLC plan were delivered repeatedly ten times. The additional shapes in modified AQA plan enable additional reproducibility checks for all the MLC pairs. During the test, the cube was aligned by imbedded fiducials and irradiated. The two angled radiation beams aimed center tungsten ball of the cube and projected 45° to phosphor screen and registered by a CCD camera of the Raven device. The centricity of the metal ball in the irradiated field was then analyzed using Matlab codes. Results: For AP images, the average offsets of X, Y, and radial directions are 0.24 ± 0.04 mm, 0.25 ± 0.02 mm and 0.35 ±± 0.03 mm respectively for the cone; 0.34 ± 0.02 mm, 0.49 ± 0.04 mm and 0.60 ± 0.04 mm respectively for the MLC. For lateral images, they are 0.63 ± 0.05 mm, 0.11 ± 0.02 mm and 0.64 ± 0.04 mm respectively for the cone, 0.79 ± 0.08 mm, −0.23 ± 0.06 mm and 0.82 ± 0.09 mm respectively for the MLC. No inconsistent MLC shapes were found in the modified AQA group. Conclusion: The results are consistent with clinically acceptable values (≤1mm from baseline). The results suggest the potential of replacement of the standard AQA test with the novel real-time Raven device for Cyberknife daily QA. The modified MLC based AQA provides a more comprehensive MLC daily QA capability. Further improvements in its resolution and automatic analyzing capability are warranted.

60 APPLIED LIFE SCIENCES↗

Quantification of a Minimum Detectable Soiling Level to Affect Photovoltaic Devices by Natural and Simulated Soils

Here, we report that soil accumulation on photovoltaic (PV) modules presents a challenge to long-term performance prediction and lifetime estimates due to the inherent difficulty in quantifying small changes over an extended period. Low mass loadings of soil are a common occurrence but remain difficult to quantify. In order to more accurately describe the specific effects of sparse soil films on PV systems, we have expanded upon an earlier technique to measure the optical losses due to an artificially applied obscurant film. A synthetic soil analog was sprayed onto glass coupons at very brief intervals with a high-volume, low-pressure pneumatic sprayer. Light transmission through the grime film was evaluated using a quantum efficiency test stand and UV/vis spectroscopy. A 0.1-g/m 2 grime loading was determined to be the limit of mass measurement sensitivity, which is similar to some reports of daily soil accumulation. Predictable, linear decreases in transmission were observed for samples with a mass loading between 0.1 and 0.5 g/m 2 . A similar change was observed for soiled coupons from an outdoor monitoring station. Collected soil from the field coupons was analyzed to develop a compositional analog for indoor studies. Lastly, natural and synthetic soils produced similar decreases in transmission.

14 SOLAR ENERGY↗

Spin correlations in the Drell–Yan process, parton entanglement, and other unconventional QCD effects

We review ideas on the structure of the QCD vacuum which had served as motivation for the discussion of various non-standard QCD effects in high-energy reactions in articles from 1984 to 1995. These effects include, in particular, transverse-momentum and spin correlations in the Drell–Yan process and soft photon production in hadron–hadron collisions. We discuss the relation of the approach introduced in the above-mentioned articles to the approach, developed later, using transverse-momentum-dependent parton distributions (TDMs). The latter approach is a special case of our more general one which allows for parton entanglement in high-energy reactions. We discuss signatures of parton entanglement in the Drell–Yan reaction. Also for Higgs-boson production in pp collisions via gluon–gluon annihilation effects of entanglement of the two gluons are discussed and are found to be potentially important. These effects can be looked for in the current LHC experiments. In our opinion studying parton-entanglement effects in high-energy reactions is, on the one hand, very worthwhile by itself and, on the other hand, it allows to perform quantitative tests of standard factorisation assumptions. Clearly, the experimental observation of parton-entanglement effects in the Drell–Yan reaction and/or in Higgs-boson production would have a great impact on our understanding how QCD works in high-energy collisions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IACMI Project 4.2: Thermoplastic Composite Development for Wind Turbine Blades

(Section 5.1) Composites made from Arkema’s Elium® thermoplastic resin and Johns Manville fiberglass were researched during this project for applications in wind blade manufacturing. A techno-economic model was developed to model this wind blade manufacturing process using these materials in place of traditional composites made with thermoset resin. This model was based on manufacturing a 61.5-meter wind blade, which showed a 4.7% reduction in wind blade cost as compared traditional thermoset materials. These cost savings were not from the thermoplastic material costing less than traditional thermoset materials, but rather from decreased capital costs, faster cycle times and reduced energy requirements and labor costs. (Section 5.2) An infusion and curing model was developed for thermoplastic composite wind blades using PAM-RTM. The primary goal was to demonstrate the infusion simulation for the Elium® resin system on a 13-meter wind blade. Additionally, the exotherm temperature was predicted and compared to measurements, which showed model results within 10% of actual measurements. (Section 5.3) Composite laminate panels and composite sandwich panels with a balsa core were produced; specimens were cut and characterized. Similar composite specimens were made with Elium® thermoplastic resin and Hexion thermoset epoxy (RIMR135/RIMH1366) to enable comparisons between these resin systems. The static test methods included: tensile, compression, in-plane shear, interlaminar shear, flexural, sandwich core shear flexure, and single cantilever beam tests for sandwich beams. Fatigue testing at room temperature was completed to composite laminate panels at a stress ratio of R=0.1 and R=10. In addition, fatigue testing to laminate panels was completed at -30°C, and at room temperature after conditioning specimens at 70°C and 90% relative humidity. Overall, mechanical test results from Elium® composites are similar to epoxy composites. (Section 5.4) Elium composite panels were produced with intentional defects such as voids and nonwetting of fibers to begin to understand performance sensitivity to defects. A thermal digital image correlation (TDIC) method provides high spatial resolution strain field at elevated temperatures and can be used to identify defective regions within composite panels. Flexural modulus differences of 21% were seen between defect and non-defect panels. Other Elium® composite panels were forced to be defective by boiling the resin after infusion, which created voids throughout the composite laminate. X-ray computed tomography scanning was used to view the internal structure of the defect panels. Defect panels had a significant reduction in fatigue life as compared to baseline panels produced without intentional defects. (Section 5.5) Lap shear specimens were fabricated to compare the lap shear strength of an off-the-shelf adhesive (Plexus MA590) and two new adhesives developed by Arkema (Bostik SAF30 90 and Bostik SAF30 120). ISO standard 4587:2003 was used to standardize the testing method and sample fabrication. Lap shear specimens were made at 1mm, 3mm, and 10mm thicknesses. The Bostik adhesive lap shear test results were similar to Plexus for all thicknesses. (Section 5.6) Fiber-reinforced polymer (FRP) composites are typically used in high-performance applications (e.g., aerospace), and their expansion into high-volume industries (e.g. consumer automotive and wind turbine blade manufacturer or similar) is hindered by their cost and a lack of efficient manufacturing techniques. Monitoring the curing process of these composites during manufacturing can improve the efficiency of the process, and therefore reduce the manufacturing cost. Cure monitoring techniques were developed that use probabilistic estimation methods and surface temperature measurements made using infrared cameras. These techniques enable real-time monitoring of the infusion process to locate manufacturing flaws, and they can, potentially, estimate residual stresses in the part. Their commercialization will help facilitate expansion of FRP composites in high-volume industries. (Section 5.7) A 13-meter composite wind blade was produced with Elium® resin and Johns Manville fiberglass; this blade was made with VARTM processing similar to how megawatt-scale wind blades are currently manufactured, but no post-mold heating was used for this thermoplastic composite blade. The wind blade underwent full-scale validation for static loading (4-different load orientations) and flapwise fatigue loading to simulate 20-years of operational loads. The thermoplastic composite wind blade withstood the loading without any noted issues and performed similar to results from a previous full-scale validation to an equivalent epoxy composite wind blade produced with the same blade molds. (Section 5.8) A study was conducted to determine the feasibility of recycling composite wind turbine blade components fabricated with glass fiber reinforced Elium® thermoplastic resin. Dissolution, which is a process unique to thermoplastic matrices, allows recovery of both the polymer matrix and full-length glass fibers, while maintaining their stiffness and strength throughout the recovery process. The economics of recycling is favorable if 50% of the glass fiber is recovered and resold for a process of $\$$ 0.28/kg, and 90% of the resin is recovered and resold at a price of $\$$ 2.50/kg.(Section 10) Recommendations are outlined for commercializing thermoplastic resin for composite wind blade production, in addition to recommended areas for future research.

17 WIND ENERGY↗

Establishing a Proficiency Testing Scheme for Drinking Water Radiochemistry

As part of its international water proficiency testing (PT) scheme, 'Aquacheck', the LGC Proficiency Testing Group has established a new water radiochemistry PT scheme. The PT scheme is aimed at laboratories who undertake radiochemical analysis on drinking water samples as part of an environmental monitoring programme. Following a scheme design and feasibility study, the new scheme was established to monitor the laboratory performance of participants undertaking the determination of gross alpha, gross beta and tritium activity. Three rounds of the new water radiochemistry PT scheme are now complete. This paper explains the process of establishing such a scheme, reviews the results so far, and addresses future development of the scheme.

54 ENVIRONMENTAL SCIENCES↗

Dexterity tests data contribute to reduction in leaded glovebox gloves use

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alphaemitting materials. The spread of radiological contamination on surfaces and airborne contamination and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Through an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program (GGJP). A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management owning glovebox processes through this program make decisions on which type of glovebox gloves (the weakest component of this safety significant system) would perform in these aggressive environments. As Low As Reasonably Achievable (ALARA) considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) glovebox gloves made from Hypalon(reg.) had been the workhorse of programmatic operations at TA-55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduced the amount of mixed TRU waste. This effort contributes to Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations. In the following report, the pros and cons of wearing leaded glovebox gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and pollution prevention benefits of this dramatic change in the glovebox system are presented.

57↗