Search NASA⌕ Search

SEARCH · Search NASA

Results for “Adding Nuclear”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Plans for Expanded Data Testing at ORNL [Slides]

VALID expansion is on-going and should provide coverage over a wider range of systems in the future. Adding additional application types beyond critical experiments can also be used in expanded data testing. Two other test suites have been developed at ORNL for other purposes, but never waste a good test suite. These suites are more likely to be relevant to testing differences in data as compared to assessing accuracy of evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diffusional creep in UO 2 informed by lower length scale simulations

Using molecular dynamics, we predict information at the atomistic scale used to develop a mechanistic UO 2 creep model for use in higher length-scale fuel performance codes. The ultimate objective of the model is to not only to capture the creep rates of UO 2 but to determine the dominant mechanism in the diffusional regime, which is still debated in the literature. It is important to have a model to capture the correct mechanisms for creep in UO 2 as this can be used as the foundation when applying to other fuels, such as doped UO 2 , and when irradiation is accounted. In last years NEAMS milestone (FY22), we developed a prelimnary model, however there were issues, for example, excessively high values of uranium vacancy concentrations at the grain boundary. This year we have addressed the issues with the previous version of the model, added a new term that accounts for the nucleation of dislocations at stress raisers (e.g., triple junctions) within the microstructure and discussed where there was disagreement in the literature about the underpinning physics (uranium self-diffusion at the grain boundary).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Multi-Layer Phoswich Radioxenon Detection System

Laboratory radioactive sources were used to characterize the phoswich detector. The CaF{sub 2} scintillator has a low light-yield and slow decay time, thus produces very small signals due to low-energy gamma rays or X-rays. Therefore, detection of 30 keV X-rays (from the xenon radioisotopes) using this layer and discriminating its very small signals from electronic noise was a challenging task. Several solutions were considered and experimentally evaluated. We found that the best solution would be extending the fast triangular filter from 10 taps to 30 taps. This will extend the peaking time of this filter from 25 nsec to 75 nsec. The digital filter is implemented in FPGA on our DPP2.0 and is used to trigger the detection system. Functionality of the new filter in capturing and discriminating 30 keV X-rays was confirmed by using a {sup 133}Ba gamma-ray source. Development of the DPP GUI software has continued with the addition of two new panels to display histograms of beta/gamma and beta/x-ray coincidence events. This includes coincidence events from a single channel, as well as two-channel, coincidence event. A pileup rejection algorithm has been implemented in the FPGA code, and controls to adjust its sensitivity have been added to the GUI. Work has begun on a new prototype system to develop a USB host interface between the PC and the FPGA to end reliance on Opal Kelly prototyping boards; the hardware for this system has been completely assembled, and the PC-side software is currently in development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Protection of Hardware: Powering Systems (Power Converter, Normal Conducting, and Superconducting Magnets)

Along with the protection of magnets and power converters, we have added a section on personnel protection because this is our highest priority in the design and operation of power systems. Thus, our topics are the protection of people, power converters, and magnet loads (protected from the powering equipment), including normal conducting magnets and superconducting magnets.

43 PARTICLE ACCELERATORS↗

Using Radiochromic Films to Characterize the Dispersion of ZrO{sub 2} Nano-sized Grain Clusters in Protective Polymer Composites

Radiation dosimetry is commonly used to prevent deterministic radiation effects in high dose medical procedures. Radiochromic films find nowadays widely application in radiotherapy, interventional procedures and CT exams for isodose and maximum skin dose measurements. Moreover the size of the irradiated area and its distribution can be performed through the reading of the individual components in the RGB-spectrum. Particularly, radiochromic film has multiple advantages over alternative dosimeters for low-kV X-rays dosimetry. Concerned to spatial resolution it is far superior to that of ionization chambers and thermoluminescent dosimeters. For high energy photon fields (keV to MeV) the most used radiochromic film commercially available belongs to the EBT Gafchromic{sup R} series. On the other hand, for low energy photon fields in the x-ray range (20 kVp to 200 kVp) the best choice belongs to the XR-QA Gafchromic{sup R} film series. In this work we demonstrate the possibility of generating 2D images of thin polymeric composites films using EBT3 and XR-QA2 Gafchromic{sup R} films exposed to 6 MeV and 40 keV x-ray photons, respectively, using the digital filtering tools of the ImageJ{sup R} free software. In this context, EBT3 films were placed on the surface of a rigid anthropomorphic phantom. Then, they were covered with a thermoplastic mask made of PCL polymer. This setup was then exposed to 2.0 Gy absorbed dose in the Linear Accelerator beam. The EBT3 films were then scanned in the high resolution mode in a commercial scanner and the images subsequently treated with digital filters. It is somehow possible to see the image of the thermoplastic mask in the scanned image. However, in the treated image it is easy to observe the mask arrangement. The unexpected phenomenon here is the EB3 film ability to detect the attenuation of high energy photons by a plastic material, which in turn has a very low mass-energy attenuation coefficient, producing a very clear 2D image. This result is discussed in terms of the high Z halides added to the sensitive layer of EB3 film, once the main components are C (42.3%), H (39.7%) and O (16.0%)1-2. Based on the above results, we have speculated about the abilities of XR-AQ films in the detection of the distribution of nano-sized particles that has high mass-energy attenuation coefficients for low energy x-rays, in polymer composites. In another investigation we tested the ability of XR-QA2 Gafchromic{sup R} films to evaluate the dispersion of ZrO{sub 2} nano-sized grain clusters in protective composites. The P(VDFTrFE)/ ZrO{sub 2} film was sandwiched between two XR-QA2 radiochromic films. In this setup, one radiochromic film is directly exposed to 100 mGy of the x-rays beam and another one measures the attenuated beam. After storage for 24 hours at room temperature under no light conditions, the irradiated radiochromic films were scanned under the same conditions in order to obtain a more reliable result. All films were scanned using the same size ROI in high resolution mode and saved as tagged image file format (TIFF). The untreated scanned image of the XR-AQ2 film directed exposed to the X-ray beam and the correspondent treated image with digital filters are shown. The untreated and treated image of the XR-AQ2 film that was exposed to the attenuated x-ray beam is shown. The image treated with digital filters seems to reproduce the dispersion of ZrO{sub 2} nano-sized grain clusters in the P(VDF-TrFE) copolymer matrix. This result is also discussed in terms of the high Z halides added to the sensitive layer of XR-AQ2 film and compared to the MEV images obtained from the P(VDF-TrFE)/ZrO{sub 2} composites. The results indicate a clear correlation between the 2D radiochromic image and the MEV photography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ x-ray absorption study of copper films in ground watersolutions

This study illustrates how the damage from copper corrosion can be reduced by modifying the chemistry of the copper surface environment. The surface modification of oxidized copper films induced by chemical reaction with Cl{sup -} and HCO{sub 3}{sup -} in aqueous solutions was monitored by in situ X-ray absorption spectroscopy. The results show that corrosion of copper can be significantly reduced by adding even a small amount of sodium bicarbonate. The studied copper films corroded quickly in chloride solutions, whereas the same solution containing 1.1 mM HCO{sub 3}{sup -} prevented or slowed down the corrosion processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DEVELOPMENT OF ENSEMBLE-BASED PROBABILISTIC FLOOD MAPS FOR PROBABLE MAXIMUM FLOOD

The magnitude and frequency of hydro-meteorological extremes are expected to increase in a changing environment that threaten the security of US energy-water assets. This includes probable maximum precipitation (PMP) and probable maximum flood (PMF) which are used as hydraulic design standards for critical infrastructures such as major hydropower reservoirs and nuclear power plants. To assess the potential flood hazards due to PMP/PMF, an integrated high resolution process-based hydro-meteorologic modeling framework was utilized to develop ensemble-based probabilistic flood maps based on best-available historic observations and future climate projections. A graphical process unit accelerated 2-dimensional hydrodynamic model was used to simulate the surface inundation areas corresponding to a total of PMF hydrographs. These ensemble-based PMF maps were compared with flood maps obtained from the conventional deterministic PMP/PMF approach, revealing added information of conditional probability of flooding. Further, a relative sensitivity test was conducted to explore the effects of various factors in the framework such as meteorological forcings, antecedent hydrologic conditions, reservoir storage, and flood model input resolution and parameters. The proposed framework better illustrates the uncertainties associated with model inputs, parameterization and hydro-meteorological factors allowing more informed decision-making for future emergency preparation.

13 HYDRO ENERGY↗

Technical Evaluation of Accelerated Basin De-Inventory Material Addition to Sludge Batch 11 (Rev. 1)

The Accelerated Basin De-inventory (ABD) program involves discarding spent nuclear fuel that is currently stored in L-Basin to the Defense Waste Processing Facility (DWPF) for vitrification. The first ABD discards will occur during the preparation of Sludge Batch (SB) 11. Savannah River Mission Completion has requested that the Savannah River National Laboratory assess the technical gaps related to the increased gadolinium poisoning requirement and the impacts of performing the Low Temperature Aluminum Dissolution (LTAD) process in Tank 51 with H-Canyon discards present. The following summarizes the evaluation of the impacts of increasing the quantity of gadolinium (and related topics) from what was previously evaluated in the SRNL studies of gadolinium-poisoned ABD material solubility, the overall ABD flowsheet review, and increasing the fissile mass loading in glass: 1) Based on literature surveys, there is no indication that organic interactions with gadolinium will be significant at the high pH (typically >13) conditions of the Concentration, Storage, and Transfer Facilities. Any interactions of gadolinium with organics in DWPF are not expected to adversely impact DWPF or downstream facilities. Thus, there is little-to-no residual risk from organic interactions with gadolinium [Gap closed]; 2) Adding depleted uranium to ABD material, targeting 235 U enrichment of 4.90% within each transfer window, will mitigate potential impacts from an increase in soluble 235 U enrichment during sludge washing and LTAD. The plan to take advantage of previous transfers and allow 235 U enrichment of >5% during the final transfer window carries a risk that Tank 51 supernate will have a 235 U enrichment of >5%, which should be evaluated for acceptance; 3) Increasing the gadolinium mass ratio to 3.0:1 Gd: 235 U(eq SLU ) should lead to the same or higher partitioning of gadolinium into the solid phase within the DWPF Chemical Process Cell, resulting in both liquid and solid phases with expected partitioning of Gd consistent with the prior solubility study [Gap closed for SB11]; 4) There are no expected impacts on DWPF melt temperature and melter operations due to the minimal ~0.2 weight percent (wt%) increase in Gd concentration relative to previous sludge batches [Gap closed for SB11]; 5) As observed previously, Gd is expected to enter the off-gas system via physical entrainment, but at a slightly higher concentration than what was observed for SB9 melter off-gas pluggage deposits (0.07 wt%) [Gap closed for SB11] ; 6) There are no expected impacts on DWPF recycle or the Recycle Collection Tank glycolate destruction process. [Gap closed for SB11]; 7) Gd is projected to be a trace component in the SB11 glass (<0.5 wt%) and can be ignored for process control. Trace components do not significantly impact glass durability, thus the conclusions of the previous Product Consistency Test evaluation at a fissile mass loading of 2,500 g fissile/m3 glass still applies to SB11. The ~0.1 wt% increase in Gd2O3 concentration relative to the previous study will not impact the predictability of SB11 glass with the DWPF Product Composition Control System (PCCS) models for durability or the acceptability of glass according to the Waste Acceptance Product Specifications (WAPS) criterion for product consistency [Gap closed for SB11]; 8) No additional Toxicity Characteristic Leaching Procedure testing is necessary for SB11 and the hazardous waste specification of the SB11 DWPF waste form is unchanged after the addition of the ABD stream [Gap closed for SB11]. The following summarizes the evaluation of the impacts of adding two-thirds of the ABD material to Tank 51 prior to LTAD: 1) The addition of two-thirds of the ABD increases overall aluminum mass from 1.39×10 4 kg to 1.64×10 4 kg (15.5% ABD Al). The form of the insoluble portion of the Al resulting from ABD addition should be the more readily dissolved Al(OH) 3 and amorphous forms. The portion of the ABD aluminum that is processed by LTAD is expected to be completely soluble, thus requiring that less of the boehmite in the sludge be dissolved to reach the same Al target in the SB. [Gap closed for SB11]; The expected LTAD impact on other components, as related primarily to the components in ABD, are discussed. Gd is expected to remain insoluble during LTAD and not impact the solubility of other components. [Gap closed for SB11]; The addition of two-thirds of the ABD increases overall projected SB11 uranium mass from 4,740 kg to 13,100 kg (63% ABD U) and the projected plutonium mass from 86.0 kg to 89.5 kg (3.9% ABD Pu). The addition of all of the ABD increases overall projected SB11 uranium mass from 4,740 kg to 16,100 kg (70% ABD U) and the projected plutonium mass from 86.0 kg to 90.4 kg (5.3% ABD Pu). The 235 U enrichment will be ≤5%. The fissile uranium will be adequately poisoned by Gd and the fissile Pu will be adequately poisoned by Fe from the sludge. [Gap closed for SB11]; There is a low risk that ABD addition will impact the rheology or pumpability of the slurry. There is a low but higher risk of ABD addition prior to LTAD impacting the settling rate; Based on the evaluation of adding two-thirds of the ABD material and all of the ABD material prior to the LTAD process, there is no volume or mass limit that would need to be imposed on ABD additions prior to LTAD. [Gap closed for SB11]. Revision 1 of this report addresses a variation on the ABD additions and LTAD strategy where sodium hydroxide additions for LTAD may be performed intermittently or concurrently with an ABD addition window. The proposed change does not alter the conclusions of this evaluation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Limit Load and Buckling Analysis for Assessing Hanford Single-Shell Tank Dome Structural Integrity - 12278

The U.S. Department of Energy, Office of River Protection has commissioned a structural analysis of record for the Hanford single shell tanks to assess their structural integrity. The analysis used finite element techniques to predict the tank response to the historical thermal and operating loads. The analysis also addressed the potential tank response to a postulated design basis earthquake. The combined response to static and seismic loads was then evaluated against the design requirements of American Concrete Institute standard, ACI-349-06, for nuclear safety-related concrete structures. Further analysis was conducted to estimate the plastic limit load and the elastic-plastic buckling capacity of the tanks. The limit load and buckling analyses estimate the margin between the applied loads and the limiting load capacities of the tank structure. The potential for additional dome loads from waste retrieval equipment and the addition of large dome penetrations to accommodate retrieval equipment has generated additional interest in the limit load and buckling analyses. This paper summarizes the structural analysis methods that were used to evaluate the limit load and buckling of the single shell tanks. This paper summarizes the structural analysis methods that were used to evaluate the limit load and buckling limit states of the underground single shell tanks at the Hanford site. The limit loads were calculated using nonlinear finite element models that capture the progressive deformation and damage to the concrete as it approaches the limit load. Both uniform and concentrated loads over the tank dome were considered, and the analysis shows how adding a penetration in the center of the tank would affect the limit loads. For uniform surface loads, the penetration does not affect the limit load because concrete crushing and rebar yielding initiates first at the top of the wall, away from the penetration. For concentrated loads, crushing initiates at the center of the dome, so the penetration does reduce the concentrated limit load somewhat. However, the safety factors comparing the limit loads to the maximum allowable applied loads remain well above the required value of 3.0. The buckling analysis method accounts for the geometric imperfections, concrete creep, cracking and reinforcements, and concrete plasticity in determining the allowable buckling load limits. The method was demonstrated in this paper for the evaluation of a tank before and after a penetration is added in the dome center. Finite element buckling models were used to accurately calculate the linear critical buckling loads. The models showed that adding the penetration reduces the linear critical buckling load by only 2.5%. Bounding cases also showed that the possible range of soil support on the walls does not significantly affect the dome buckling loads. Buckling models of the full 360 deg. dome also showed that the dome is more resistant to buckling when the load is offset than when it is positioned over the center. These limit load and buckling analysis methods are being used at the Hanford site to assess the tank loads that can be safely applied during future waste retrieval activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Three-Dimensional Analysis of Recurrence Patterns in Rectal Cancer: The Cranial Border in Hypofractionated Preoperative Radiotherapy Can Be Lowered

Purpose: The aim of this study was to determine whether and where the radiotherapy (RT) clinical target volume (CTV) could be reduced in short-course preoperative treatment of rectal cancer patients. Methods and Materials: Patients treated in the Dutch total mesorectal excision trial, with a local recurrence were analyzed. For 94 (25 who underwent radiation therapy 69 who did not) of 114 patients with a local recurrence, the location of the recurrence was placed in a three-dimensionalthree (3D) model. The data in the 3D model were correlated to the clinical trial data to distinguish a group of patients eligible for CTV reduction. Effects of CTV reduction on dose to the small bowel was tested retrospectively in a dataset of 8 patients with three-field conformal plans and intensity-modulated RT (IMRT). Results: The use of preoperative RT mainly reduces anastomotic, lateral, and perineal recurrences. In patients without primary nodal involvement, no recurrences were found cranially of the S2-S3 interspace, irrespective of the delivery of RT. In patients without primary nodal involvement and a negative circumferential resection margin (CRM), only one recurrence was found cranial to the S2-S3 interspace. With a cranially reduced CTV to the S2-S3 interspace, over 60% reduction in absolute small bowel exposure at dose levels from 15 to 35 Gy could be achieved with three-field conventional RT, increasing to 80% when IMRT is also added. Conclusions: The cranial border of the CTV can safely be lowered for patients without expected nodal or CRM involvement, yielding a significant reduction of dose to the small bowel. Therefore, a significant reduction of acute and late toxicity can be expected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Spot Size and Beam-Shaping Devices on the Treatment Plan Quality for Pencil Beam Scanning Proton Therapy

Purpose: This study aimed to assess the clinical impact of spot size and the addition of apertures and range compensators on the treatment quality of pencil beam scanning (PBS) proton therapy and to define when PBS could improve on passive scattering proton therapy (PSPT). Methods and Materials: The patient cohort included 14 pediatric patients treated with PSPT. Six PBS plans were created and optimized for each patient using 3 spot sizes (∼12-, 5.4-, and 2.5-mm median sigma at isocenter for 90- to 230-MeV range) and adding apertures and compensators to plans with the 2 larger spots. Conformity and homogeneity indices, dose-volume histogram parameters, equivalent uniform dose (EUD), normal tissue complication probability (NTCP), and integral dose were quantified and compared with the respective PSPT plans. Results: The results clearly indicated that PBS with the largest spots does not necessarily offer a dosimetric or clinical advantage over PSPT. With comparable target coverage, the mean dose (D{sub mean}) to healthy organs was on average 6.3% larger than PSPT when using this spot size. However, adding apertures to plans with large spots improved the treatment quality by decreasing the average D{sub mean} and EUD by up to 8.6% and 3.2% of the prescribed dose, respectively. Decreasing the spot size further improved all plans, lowering the average D{sub mean} and EUD by up to 11.6% and 10.9% compared with PSPT, respectively, and eliminated the need for beam-shaping devices. The NTCP decreased with spot size and addition of apertures, with maximum reduction of 5.4% relative to PSPT. Conclusions: The added benefit of using PBS strongly depends on the delivery configurations. Facilities limited to large spot sizes (>∼8 mm median sigma at isocenter) are recommended to use apertures to reduce treatment-related toxicities, at least for complex and/or small tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nitrated graphene oxide and its catalytic activity in thermal decomposition of ammonium perchlorate

Highlights: • The NGO was synthesized by nitrifying homemade GO. • The N content of resulted NGO is up to 1.45 wt.%. • The NGO can facilitate the decomposition of AP and release much heat. - Abstract: Nitrated graphene oxide (NGO) was synthesized by nitrifying homemade GO with nitro-sulfuric acid. Fourier transform infrared spectroscopy (FTIR), laser Raman spectroscopy, CP/MAS {sup 13}C NMR spectra and X-ray photoelectron spectroscopy (XPS) were used to characterize the structure of NGO. The thickness and the compositions of GO and NGO were analyzed by atomic force microscopy (AFM) and elemental analysis (EA), respectively. The catalytic effect of the NGO for the thermal decomposition of ammonium perchlorate (AP) was investigated by differential scanning calorimetry (DSC). Adding 10% of NGO to AP decreases the decomposition temperature by 106 °C and increases the apparent decomposition heat from 875 to 3236 J/g.

36 MATERIALS SCIENCE↗

Transformation of Uranyl Peroxide Studtite, [(UO 2 )(O 2 )(H 2 O) 2 ](H 2 O) 2 , to Soluble Nanoscale Cage Clusters

The dissolution behavior of uranyl peroxide studtite, [(UO 2 )(O 2 )(H 2 O) 2 ](H 2 O) 2 , was examined under a wide range of alkaline aqueous environments with and without the addition of hydrogen peroxide. In the absence of added H 2 O 2 , studtite dissolved in aqueous solutions with a tetraethylammonium hydroxide to uranium molar ratio greater than 0.5, and the resulting species in solution characterized by Raman spectroscopy and electrospray ionization mass spectrometry (ESI-MS) is the uranyl peroxide nanocluster U 24 , [(UO 2 )(O 2 )(OH)] 24 24– . This is the first demonstration of the formation of uranyl peroxide nanoclusters from studtite in a solution lacking additional hydrogen peroxide. In similar systems containing added hydrogen peroxide (0.01 M – 1.0 M), studtite dissolved in solutions with a TEAOH to uranium ratio greater than 0.1, and the resulting uranyl peroxide species in solution was U 28 , [(UO 2 )(O 2 ) 1.5 ] 28 28– .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic modeling of an argon-doped shock-ignition implosion

We present results from the spectral postprocessing of a one-dimensional hydrodynamic simulation of an argon-doped, warm-shell shock-ignition implosion with a detailed atomic and radiation physics model. The argon tracer is added to the deuterium filling in the core for diagnostic purposes. Spectral features in the emergent intensity distribution in the photon energy range of the argon K-shell spectrum that have potential for diagnostic application are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the effect of adding an on-axis jet to Ar gas puff Z pinches on Z.

Double-shell Ar gas puff implosions driven by 16.5±0.5 MA on the Z generator at Sandia National Laboratories are very effective emitters of Ar K-shell radiation (photon energy >3 keV), producing yields of 330 ± 9% kJ (B. Jones et al., Phys. Plasmas, 22, 020706, 2015). In addition, previous simulations and experiments have reported dramatic increases in K-shell yields when adding an on-axis jet to double shell gas puffs for some configurations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calculation of the C 12 + C 12 sub-barrier fusion cross section in an imaginary-time-dependent mean field theory

The 12 C + 12 C sub-barrier fusion cross section is calculated within the framework of a time-dependent Hartree-Fock-based classical model using the Feynman path-integral method. The modified astrophysical S* factor is compared to direct and indirect experimental results. A good agreement with the direct data is found. In the lower-energy region where recent analyses of experimental data obtained with the Trojan horse method (THM) lead to contrasting results, the model predicts a nonresonant S* factor half-way between those results. Low-energy resonances revealed in the THM data are added to the calculation, and the relative reaction rate in the Gamow region is calculated. In particular, including 0 + resonances result in some agreement with the THM data. Here, the role of different resonances is discussed in detail, and their influence on the reaction rate at temperatures relevant to stellar evolution is investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detailed high-accuracy megavoltage transmission measurements: A sensitive experimental benchmark of EGSnrc

Purpose: There are three goals for this study: (a) to perform detailed megavoltage transmission measurements in order to identify the factors that affect the measurement accuracy, (b) to use the measured data as a benchmark for the EGSnrc system in order to identify the computational limiting factors, and (c) to provide data for others to benchmark Monte Carlo codes. Methods: Transmission measurements are performed at the National Research Council Canada on a research linac whose incident electron parameters are independently known. Automated transmission measurements are made on-axis, down to a transmission value of {approx}1.7%, for eight beams between 10 MV (the lowest stable MV beam on the linac) and 30 MV, using fully stopping Be, Al, and Pb bremsstrahlung targets and no fattening filters. To diversify energy differentiation, data are acquired for each beam using low-Z and high-Z attenuators (C and Pb) and Farmer chambers with low-Z and high-Z buildup caps. Experimental corrections are applied for beam drifts (2%), polarity (2.5% typical maximum, 6% extreme), ion recombination (0.2%), leakage (0.3%), and room scatter (0.8%)-the values in parentheses are the largest corrections applied. The experimental setup and the detectors are modeled using EGSnrc, with the newly added photonuclear attenuation included (up to a 5.6% effect). A detailed sensitivity analysis is carried out for the measured and calculated transmission data. Results: The developed experimental protocol allows for transmission measurements with 0.4% uncertainty on the smallest signals. Suggestions for accurate transmission measurements are provided. Measurements and EGSnrc calculations agree typically within 0.2% for the sensitivity of the transmission values to the detector details, to the bremsstrahlung target material, and to the incident electron energy. Direct comparison of the measured and calculated transmission data shows agreement better than 2% for C (3.4% for the 10 MV beam) and typically better than 1% for Pb. The differences can be explained by acceptable photon cross section changes of Less-Than-Or-Slanted-Equal-To 0.4%. Conclusions: Accurate transmission measurements require accounting for a number of influence quantities which, if ignored, can collectively introduce errors larger than 10%. Accurate transmission calculations require the use of the most accurate data and physics options available in EGSnrc, particularly the more accurate bremsstrahlung angular sampling option and the newly added modeling of photonuclear attenuation. Comparison between measurements and calculations implies that EGSnrc is accurate within 0.2% for relative ion chamber response calculations. Photon cross section uncertainties are the ultimate limiting factor for the accuracy of the calculated transmission data (Monte Carlo or analytical).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hanford Double Shell Waste Tank Corrosion Studies - Final Report FY2017

Corrosion studies of Hanford Double-Shell Tanks (DSTs) at Savannah River National Laboratory (SRNL) were focused on New Limits testing using statistically design matrices for a high concentration of hydroxide (1.2 M) and testing at various interior points to establish corrosion control guidelines towards pitting corrosion. Ammonia was also added into the statistical design to determine inhibition effects. Additional electrochemical studies of individual organic species and nitrous oxide were tested in a AN-102 based simulant with no organics to compare inhibiting properties of a specific specie and measure any electrochemical improvement towards pitting corrosion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗