Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analytical Method Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Advancing electrochemical impedance analysis through innovations in the distribution of relaxation times method

Electrochemical impedance spectroscopy (EIS) is a key tool across various scientific disciplines, including energy sciences, chemistry, and biology, enabling the analysis of electrochemical systems. However, conventional methods for interpreting EIS data are often complex and model dependent. The distribution of relaxation times (DRT) offers a non-parametric approach that simplifies the interpretation process by providing a timescale interpretation of EIS data. This article provides a comprehensive review of current methods for DRT inversion. Additionally, a survey of practitioners highlights key challenges in the field. Here, the findings underscore the need for standardized DRT analysis and benchmarks, as well as the development of automated analysis tools. These advancements would improve the usability and interpretability of EIS data. Ultimately, implementing these improvements could not only propel the field forward but also expand the application of DRT in scientific research by making it accessible to a broader range of researchers, including those without specialized expertise in programming or statistics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Droplet Combustion in a Slow Convective Flow

The influences of slow convective flow on droplet combustion, particularly in the low Reynolds number regime, have received very little attention in the past. Most studies in the literature are semi-empirical in nature and they were motivated by spray combustion applications in the moderate to high Reynolds number regime. None of the limited number of fundamental theoretical studies applicable to low Reynolds numbers have been verified by rigorous experimental data. Moreover, many unsteady phenomena associated with fluid-dynamic unsteadiness, such as impulsive starting or stopping of a burning droplet, or flow acceleration/deceleration effects, have not been investigated despite their importance in practical applications. In this study we investigate the effects of slow convection on droplet burning dynamics both experimentally and theoretically. The experimental portion of the study involves both ground-based experiments in the drop towers and future flight experiments on board the International Space Station. Heptane and methanol are used as test fuels, and this choice complements the quiescent-environment studies of the Droplet Combustion Experiment (DCE). An analytical model that employs the method of matched asymptotic expansions and uses the ratio of the convective velocity far from the droplet to the Stefan velocity at its surface as the small parameter for expansion has also been developed as a part of this investigation. Results from the ground-based experiments and comparison with the analytical model are presented in this report.

Nayagam, V.↗

Development of a verification program for deployable truss advanced technology

Use of large deployable space structures to satisfy the growth demands of space systems is contingent upon reducing the associated risks that pervade many related technical disciplines. The overall objectives of this program was to develop a detailed plan to verify deployable truss advanced technology applicable to future large space structures and to develop a preliminary design of a deployable truss reflector/beam structure for use a a technology demonstration test article. The planning is based on a Shuttle flight experiment program using deployable 5 and 15 meter aperture tetrahedral truss reflections and a 20 m long deployable truss beam structure. The plan addresses validation of analytical methods, the degree to which ground testing adequately simulates flight and in-space testing requirements for large precision antenna designs. Based on an assessment of future NASA and DOD space system requirements, the program was developed to verify four critical technology areas: deployment, shape accuracy and control, pointing and alignment, and articulation and maneuvers. The flight experiment technology verification objectives can be met using two shuttle flights with the total experiment integrated on a single Shuttle Test Experiment Platform (STEP) and a Mission Peculiar Experiment Support Structure (MPESS). First flight of the experiment can be achieved 60 months after go-ahead with a total program duration of 90 months.

Dyer, Jack E.↗

Small-angle X-ray scattering, synchrotron radiation, and the structure of bio- and nanosystems

Small-angle X-ray scattering is a universal diffraction method for studying the supra-atomic structure of matter. The potential of this technique has greatly increased in recent years due to the development of bright synchrotron radiation sources. The extensive use of these sources, in combination with new techniques for analyzing scattering data and structure modeling, made small-angle scattering one of the most effective analytical methods for studying nanoscale structures. In this review, after a brief outline of the basic principles of small-angle scattering by isotropic dispersed nanosystems, we consider two areas of nanodiagnostics, in which the progress in the small-angle experiment and the latest techniques for interpreting scattering data has become pronounced in recent years. These areas-the analysis of the structure of biological macromolecules in a solution and structural studies of metal nanoparticles synthesized in polymer and aqueous media-are illustrated by examples of practical biological and nanotechnologycal applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

“Third-body” collision parameters for hydrocarbons, alcohols, and hydroperoxides and an effective internal rotor approach for estimating them

Collision rate constants and third-body collision efficiencies are calculated for more than 300 alkanes, alcohols, and hydroperoxides, for the bath gases He, Ar, H 2 , and N 2 , and from 300 to 2000 K. The data set includes highly branched species and species with as many as 16 nonhydrogen atoms N , and it is analyzed to develop strategies for estimating collision properties more generally. Simple analytic formulas describing the Lennard-Jones collision parameters $σ$ and $ε$ are obtained for each of the three classes of systems as a function of N . Trends in the collision efficiency range parameter $α$ = $\langle$Δ E d $\rangle$ are more complicated, and a method is developed and validated for estimating $α$ based on the numbers and types of internal rotors and oxygen-containing groups. Specifically, the approach maps the expected value of $α$ for a branched alkane, alcohol, or hydroperoxide onto those for the corresponding normal (linear) series via an effective number of nonhydrogen atoms N eff . The prescription for N eff is based on counting internal rotor types and is shown to be insensitive to temperature and fairly insensitive to the identity of the bath gas. Together, these strategies allow for the ready estimation of the collision parameters $σ$, $ε$, and $α$ so long as results for the associated linear series are available.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility Mass Spectrometry Direct Isotope Abundance Analysis

The nuclear forensics community is currently engaged in the analysis of illicit nuclear or radioactive material for the purposes of non-proliferations and attribution. One technique commonly employed for gathering nuclear forensics information is isotope analysis. At present, the state-of-the-art methodology for obtaining isotopic distributions is thermal ionization mass spectrometry (TIMS). Although TIMS is highly accurate at determining isotope distributions, the technique requires an elementally pure sample to perform the measurement. The required radiochemical separations give rise to sample preparation times that can be in excess of one to two weeks. Clearly, the nuclear forensics community is in need of instrumentation and methods that can expedite their decision making process in the event of a radiological release or nuclear detonation. Accordingly, we are developing instrumentation that couples a high resolution IM drift cell to the front end of a MS. The IM cell provides a means of separating ions based upon their collision cross-section and mass-to-charge ratio (m/z). Two analytes with the same m/z, but with different collision cross-sections (shapes) would exit the cell at different times, essentially enabling the cell to function in a similar manner to a gas chromatography (GC) column. Thus, molecular and atomic isobaric interferences can be effectively removed from the ion beam. The mobility selected chemical species could then be introduced to a MS for high-resolution mass analysis to generate isotopic distributions of the target analytes. The outcome would be an IM/MS system capable of accurately measuring isotopic distributions while concurrently eliminating isobaric interferences and laboratory radiochemical sample preparation. The overall objective of this project is developing instrumentation and methods to produce near real-time isotope distributions with a modular mass spectrometric system that performs the required gas-phase chemistry and separations. The system couples a high-resolution ion mobility (IM) drift cell to the front end of a mass spectrometer (MS) allowing for chemical separation prior to isotope distribution analyses. This will yield isotope ratio measurement capabilities with minimal sample preparation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward continuum gyrokinetic study of high-field mirrors

High-temperature superconducting (HTS) magnetic mirrors under development exploit strong fields with high mirror ratio to compress loss cones and enhance confinement and may offer cheaper, more compact fusion power plant candidates. This new class of devices could exhibit largely unexplored interchange and gradient-driven modes. Such instabilities, and methods to stabilize them, can be studied with gyrokinetics, given the strong magnetization and prevalence of kinetic effects. Our focus here is to (a) determine if oft-used gyrokinetic models for open field lines produce the electron-confining (Pastukhov) electrostatic potential and (b) examine and address challenges faced by gyrokinetic codes in studying HTS mirrors. Here, we show that a one-dimensional limit of said models self-consistently develops a potential qualitatively approaching the analytical Pastukhov level. Additionally, we describe the computational challenges of studying high mirror ratios with open field line gyrokinetic solvers and offer a force softening method to mitigate small time steps needed for time integration in colossal magnetic field gradients produced by HTS coils, providing a 19X speedup.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methods studies toward simplified rotor-body dynamics, part 1

This report is directed to the problem of developing an adequate but not overly complex linear flight dynamics analytical model of a rotorcraft to study stability, control, gust and random turbulence responses. Since the conventional flight dynamics analysis using quasisteady rotor derivatives is adequate for the long period modes like the phugoid mode, only short time responses are considered here, where rotor-body coupling is of importance. Thus the body motion consists of pitch, roll and vertical motion, omitting linear longitudinal and lateral and yaw perturbations. Five analytical models of varying degree of sophistication are applied to a hypothetical hingeless compound helicopter operating up to .8 rotor advance ratio. Stability and response data are obtained for the basic helicopter and for the vehicle with two simple control feedback systems.

Hohenemser, K. H.↗

Analytical verification of undesirable properties of direct model reference adaptive control algorithms

The present investigation is concerned with a new method, called 'final approach analysis', which has been developed to analyze the dynamic properties of a class of direct adaptive control algorithms. Particular attention is given to the robustness of these algorithms to a number of aspects. These aspects are related to the generation of high frequencies in the plant control signal, to excessive bandwidth of the adaptive control loop resulting in excitation of unmodeled dynamics, and, consequently, leading to dynamic instability of the closed-loop adaptive system, and, thirdly, to noise corrupted measurements. The final approach analysis is useful because it can be used in a constructive way to adjust the adaptive gains so as to limit the closed-loop system bandwidth and to ameliorate some of the undesirable characteristics of existing adaptive algorithms.

Rohrs, C. E.↗

Analytical Simulation of the Effects of Local Mechanisms on the Tensile Response of CMC Minicomposites

A micromechanics-based method based on a fiber shear lag analysis was developed to analyze the fast fracture response of uncoated ceramic matrix minicomposites under room temperature conditions. The model was applied to two SiCf/SiC minicomposite systems that were fabricated by Rolls-Royce and the University of Connecticut. The analysis approach does not require the assumption that matrix cracks propagate along the entire width of the minicomposite. The ratio of the fiber slip length to the crack spacing was found to be a key parameter driving the stress level at which the proportional limit takes place and the secondary modulus. Parametric studies were performed to investigate the effect of interfacial shear stress, fiber volume fraction and percentage of the composite that remains uncracked on the proportional limit stress and the composite secondary modulus. This work will allow increased understanding of the key material mechanisms that take place during the fast fracture loading and can be expanded to provide improved analysis methods for full macro composites. simulations to simulations of a flat panel impact test, have been performed to fully exercise and evaluate the capabilities of the developed model.

Micromechanics↗

A Quantitative Method for In Situ Pump-Beam Metrology in 4D Ultrafast Electron Microscopy

In this work, we report a method for measuring spot size and focusing conditions of the femtosecond (fs) excitation laser in situ at the specimen location in 4D ultrafast electron microscopy (UEM). The method makes use of threshold laser ablation behaviors of thin amorphous carbon membranes. For Gaussian beam profiles and for ablation threshold fluence values, we analytically derive expressions describing the relationship between ablated hole size and the actual laser spot size. Using these expressions, we developed experimental procedures for characterizing the shape and spot size of the pump beam at the specimen. We demonstrate the viability of the approach for incident excitation wavelengths of 343 nm and 515 nm, thus illustrating the applicability of the method to a range of optical wavelengths without modification. Further, we show that by measuring ablated hole size as a function of focusing condition, a full metrological characterization of the Gaussian beam propagation properties can be performed. Finally, we find good agreement for spot sizes determined with this method and with those determined by extrapolation from measurements taken outside the microscope column. Overall, this method is a simple, cost-effective means for accurate and precise determination of key pump-beam parameters in situ at the specimen location in UEM experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-A-19A-12: A GPU-Accelerated and Monte Carlo-Based Intensity Modulated Proton Therapy Optimization System

Purpose: To develop a clinically applicable intensity modulated proton therapy (IMPT) optimization system that utilizes more accurate Monte Carlo (MC) dose calculation, rather than analytical dose calculation. Methods: A very fast in-house graphics processing unit (GPU) based MC dose calculation engine was employed to generate the dose influence map for each proton spot. With the MC generated influence map, a modified gradient based optimization method was used to achieve the desired dose volume histograms (DVH). The intrinsic CT image resolution was adopted for voxelization in simulation and optimization to preserve the spatial resolution. The optimizations were computed on a multi-GPU framework to mitigate the memory limitation issues for the large dose influence maps that Result from maintaining the intrinsic CT resolution and large number of proton spots. The dose effects were studied particularly in cases with heterogeneous materials in comparison with the commercial treatment planning system (TPS). Results: For a relatively large and complex three-field bi-lateral head and neck case (i.e. >100K spots with a target volume of ∼1000 cc and multiple surrounding critical structures), the optimization together with the initial MC dose influence map calculation can be done in a clinically viable time frame (i.e. less than 15 minutes) on a GPU cluster consisting of 24 Nvidia GeForce GTX Titan cards. The DVHs of the MC TPS plan compare favorably with those of a commercial treatment planning system. Conclusion: A GPU accelerated and MC-based IMPT optimization system was developed. The dose calculation and plan optimization can be performed in less than 15 minutes on a hardware system costing less than 45,000 dollars. The fast calculation and optimization makes the system easily expandable to robust and multi-criteria optimization. This work was funded in part by a grant from Varian Medical Systems, Inc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Plant-based Food and Feed Protein Structure Changes Induced by Gene-transformation heating and bio-ethanol processing: A Synchrotron-based Molecular Structure and Nutrition Research Program

Unlike traditional 'wet' analytical methods which during processing for analysis often result in destruction or alteration of the intrinsic protein structures, advanced synchrotron radiation-based Fourier transform infrared microspectroscopy has been developed as a rapid and nondestructive and bioanalytical technique. This cutting-edge synchrotron-based bioanalytical technology, taking advantages of synchrotron light brightness (million times brighter than sun), is capable of exploring the molecular chemistry or structure of a biological tissue without destruction inherent structures at ultra-spatial resolutions. In this article, a novel approach is introduced to show the potential of the advanced synchrotron-based analytical technology, which can be used to study plant-based food or feed protein molecular structure in relation to nutrient utilization and availability. Recent progress was reported on using synchrotron-based bioanalytical technique synchrotron radiation-based Fourier transform infrared microspectroscopy and diffused reflectance infrared Fourier transform spectroscopy to detect the effects of gene-transformation (Application 1), autoclaving (Application 2), and bio-ethanol processing (Application 3) on plant-based food and feed protein structure changes on a molecular basis. The synchrotron-based technology provides a new approach for plant-based protein structure research at ultra-spatial resolutions at cellular and molecular levels.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining pseudoscalar meson photoproduction amplitudes from complete experiments

In preparation for a new generation of complete experiments with the goal of performing a high precision extraction of pseudoscalar meson photo-production amplitudes, we present expressions that allow the direct numerical calculation of matrix elements with arbitrary spin projections from Chew-Goldberger-Low-Nambu (CGLN) amplitudes. We use this numerical tool to verify the most general analytic form of the cross section, dependent upon the three polarization vectors of the beam, target and recoil baryon, including all single, double and triple-polarization terms involving 16 spin-dependent observables. Analytic expressions that determine the recoil baryon polarization are presented, together with examples of their potential use with quasi-4? detectors to deduce observables. We assemble the analytic equations relating the 16 experimental observables and the CGLN amplitudes and use our independent method of numerical evaluation to resolve sign differences that exist in the literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Close-Range Photogrammetry & Next Generation Spacecraft

NASA is focusing renewed attention on the topic of large, ultra-lightweight space structures, also known as 'gossamer' spacecraft. Nearly all of the details of the giant spacecraft are still to be worked out. But it's already clear that one of the most challenging aspects will be developing techniques to align and control these systems after they are deployed in space. A critical part of this process is creating new ground test methods to measure gossamer structures under stationary, deploying and vibrating conditions for validation of corresponding analytical predictions. In addressing this problem, I considered, first of all, the possibility of simply using conventional displacement or vibration sensor that could provide spatial measurements. Next, I turned my attention to photogrammetry, a method of determining the spatial coordinates of objects using photographs. The success of this research and development has convinced me that photogrammetry is the most suitable method to solve the gossamer measurement problem.

Pappa, Richard S.↗

SU-F-T-145: Modeling of a Proton Pencil Beam Partially Blocked by a Collimator

Purpose: To develop a mathematical model of the fluence distribution of a proton pencil beam that is partially blocked by a collimator. Methods: In one dimension, an exact analytical solution of the proton distribution behind a collimator edge was derived, taking the beam’s phase space, the edge position, and the scattering downstream of the collimator as input. Extension to two dimensions was achieved using a Clarkson-like Method: determine the radial distances from each calculation point to the collimator outline, calculate the beam’s phase space in the direction of each radial line, apply the one-dimensional model along each radial line, and sum the contributions. A Matlab implementation of the full model produced high-resolution distributions with relatively short calculation times (of about 2 ms per calculation point). The model was validated by comparison to Monte Carlo simulations for select pencil beam phase space distributions and collimator shapes. Results: Agreement between model and simulation confirm the exact mathematical solution of the one-dimensional model. In two dimensions the agreement is reasonable, but not exact, due to the approximations introduced in the Clarkson-like method. Conclusion: A model has been developed and validated that gives the lateral fluence distribution of a pencil beam beyond a collimator. Notably, this model does not include free parameters and the final fluence is completely determined by the phase space parameters of the beam, already existing in the treatment planning system, as well as both axial and lateral position of the aperture edge. As such, it can be incorporated in a full pencil-beam dose calculation algorithm allowing for the modeling of field-specific collimators in proton pencil beam scanning and, potentially, the optimization of collimator shape and/or pencil phase space in addition to the customary spot weight optimization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distinguishing enantiomeric amino acids with chiral cyclodextrin adducts and structures for lossless ion manipulations

Enantiomeric molecular evaluations remain an enormous challenge for current analytical techniques. To date, derivatizations strategies and long separation times are generally required in these studies, and the development and implementation of new approaches is greatly desired to increase speed and distinguish currently unresolvable compounds. Herein, we describe a method using chiral cyclodextrin adducts and structures for lossless ion manipulations (SLIM) ion mobility to achieve rapid, high resolution separations of D and L enantiomeric amino acids. In the analyses, chiral cyclodextrin adducts are added to each sample. Two cyclodextrins were found to sandwich each amino acid and form host-guest noncovalent complexes that were distinct for each D and L amino acid pair studied and thus separable with ion mobility (IM) in SLIM devices. The SLIM was also used to accumulate much larger ion populations than previously feasible for evaluation and therefore allow enantiomeric measurements of higher sensitivity and resolution than previously reported by any other IM-based approach.

chiral separations, cyclodextrins, enantiomers, io↗