Analyzing the Calibration History of Radiometers for Determining Optimal Calibration Day(s)

This study investigates the effects of calibrating radiometers using one day or multiple cloudless days as recommended by ASTM and ISO standards. The results demonstrate good responsivity agreement with estimated uncertainty error bars over the years for various radiometers under various Broadband Outdoor Radiometer Calibration (BORCAL) events at both the National Renewable Energy Laboratory and the Southern Great Plains facility. The BORCAL method appears to justify the use of a single calibration day with enough data points to attain repeatable calibration results.

BORCAL↗

Space View Issues for Hyperspectral Sounders

The expectation for climate quality measurements from hyperspectral sounders is absolute calibration accuracy at the 100 mK level and stability at the < 40 mK/decade level. The Atmospheric InfraRed Sounder (AIRS)1, Cross-track Infrared Sounder (CrIS), and Infrared Atmospheric Sounding Interferometer (IASI) hyperspectral sounders currently in orbit have been shown to agree well over most of their brightness temperature range. Some larger discrepancies are seen, however, at the coldest scene temperatures, such as those seen in Antarctic winter and deep convective clouds. A key limiting factor for the calibrated scene radiance accuracy for cold scenes is how well the effective radiance of the cold space view pertains to the scene views. The space view signal is composed of external sources and instrument thermal emission at about 270 K from the scan mirror, external baffles, etc. Any difference in any of these contributions between space views and scene views will impact the absolute calibration accuracy, and the impact can be critical for cold scenes. Any change over time in these will show up as an apparent trend in calibrated radiances. We use AIRS data to investigate the validity of the space view assumption in view of the 100 mK accuracy and 40 mK/decade trend expectations. We show that the space views used for the cold calibration point for AIRS v5 Level-1B products meet these standards except under special circumstances and that AIRS v6 Level-1B products will meet them under all circumstances. This analysis also shows the value of having multiple distinct space views to give operational redundancy and analytic data, and that reaching climate quality requires continuing monitoring of aging instruments and adjustment of calibration.

trends↗

Absolute radiometric calibration of detectors between 200-600 A

A description is given of the experimental methods used in the calibration procedure, taking into account the source of radiant energy, the monochromator, the absolute standard detector, and the transfer standards. The experimental apparatus is discussed. A graph showing the effect of beam motion on the detected signal is presented and a block diagram of the calibration electronic system is provided.

Saloman, E. B.↗

ER-2 High Altitude Solar Cell Calibration Flights

Evaluation of space photovoltaics using ground-based simulators requires primary standard cells which have been characterized in a space or near-space environment. Due to the high cost inherent in testing cells in space, most primary standards are tested on high altitude fixed wing aircraft or balloons. The ER-2 test platform is the latest system developed by the Glenn Research Center (GRC) for near-space photovoltaic characterization. This system offers several improvements over GRC's current Learjet platform including higher altitude, larger testing area, onboard spectrometers, and longer flight season. The ER-2 system was developed by GRC in cooperation with NASA's Armstrong Flight Research Center (AFRC) as well as partners at the Naval Research Laboratory and Air Force Research Laboratory. The system was designed and built between June and September of 2014, with the integration and first flights taking place at AFRC's Palmdale facility in October of 2014. Three flights were made testing cells from GRC as well as commercial industry partners. Cell performance data was successfully collected on all three flights as well as solar spectra. The data was processed using a Langley extrapolation method, and performance results showed a less than half a percent variation between flights, and less than a percent variation from GRC's current Learjet test platform.

ER-2↗

The development of two-dimensional object identification techniques

This report marks the end of the first year of an anticipated three year effort to study methods for numerically identifying objects according to shape in two dimensions. The method is based upon comparing the unit gradient of an observed object and the unit gradient of a standard object over a specified range of points. The manner in which the gradients are compared forms the basis of a shape recognition scheme, which is then applied to simple closed plane figures. The gradient based method is calibrated by using various distorted objects in comparison with a set of standard reference objects. The use of pattern recognition techniques for computer identification of two-dimensional figures will be investigated during the second and third years of this project.

Lebby, Gary↗

Measurement of conductivity and permittivity on samples sealed in nuclear magnetic resonance tubes

We present a broadband impedance spectroscopy instrument designed to measure conductivity and/or permittivity for samples that are sealed in glass tubes, such as the standard 5 mm tubes used for nuclear magnetic resonance experiments. The calibrations and corrections required to extract the dielectric properties of the sample itself are outlined. It is demonstrated that good estimates of the value of dc-conductivity can be obtained even without correcting for the effects of glass or air on the overall impedance. The approach is validated by comparing data obtained from samples sealed in nuclear magnetic resonance tubes with those from standard dielectric cells, using glycerol and butylmethylimidazolium-hexafluorophosphate as respective examples of a molecular and an ionic liquid. This instrument and approach may prove useful for other studies of permittivity and conductivity where contact to the metal electrodes or to the ambient atmosphere needs to be avoided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SIMS CHARACTERIZATION OF NITROGEN DOPING OF LCLS-II-HE PRODUCTION CAVITIES

The thermal diffusion of nitrogen into the surface of niobium has been shown to yield superior low-loss SRF performance. An effective solution was identified and promptly employed in the production of cryomodules for LCLS-II. With added experience and R&D, a modified process was chosen for use in the upgrade for LCLS-II-HE. Largely motivated by this circumstance, supporting research has significantly refined the technique for making calibrated secondary ion mass spectrometry (SIMS) measurements of the N concentration depth profiles produced by production processes. Standardized reference samples were included with four HE production cavities in their N-doping furnace runs. We report the calibrated dynamic SIMS depth profiles of N, C, and O for these samples, together with the cryogenic acceptance test performance of the associated cavities. Interpretation and comparison with similar samples acquired in other furnaces highlights the importance of intentional process quality control of furnace conditions.

Reece, Charles↗

SIMS CHARACTERIZATION OF NITROGEN DOPING OF LCLS-II-HE PRODUCTION CAVITIES

The thermal diffusion of nitrogen into the surface of niobium has been shown to yield superior low-loss SRF performance. An effective solution was identified and promptly employed in the production of cryomodules for LCLS-II. With added experience and R&D, a modified process was chosen for use in the upgrade for LCLS-II-HE. Largely motivated by this circumstance, supporting research has significantly refined the technique for making calibrated secondary ion mass spectrometry (SIMS) measurements of the N concentration depth profiles produced by production processes. Standardized reference samples were included with four HE production cavities in their N-doping furnace runs. We report the calibrated dynamic SIMS depth profiles of N, C, and O for these samples, together with the cryogenic acceptance test performance of the associated cavities. Interpretation and comparison with similar samples acquired in other furnaces highlights the importance of intentional process quality control of furnace conditions.

Reece, Charles↗

THE RADIAL VELOCITY EXPERIMENT (RAVE): THIRD DATA RELEASE

We present the third data release of the RAdial Velocity Experiment (RAVE) which is the first milestone of the RAVE project, releasing the full pilot survey. The catalog contains 83,072 radial velocity measurements for 77,461 stars in the southern celestial hemisphere, as well as stellar parameters for 39,833 stars. This paper describes the content of the new release, the new processing pipeline, as well as an updated calibration for the metallicity based upon the observation of additional standard stars. Spectra will be made available in a future release. The data release can be accessed via the RAVE Web site.

79 ASTRONOMY AND ASTROPHYSICS↗

In-field Calibration of a Fast Neutron Collar for the Measurement of Fresh PWR Fuel Assemblies

A new neutron collar has been designed for the measurement of fresh LEU fuel assemblies. This collar uses “fast mode” measurement to reduce the effect of burnable poison rods on the assay and thus reduce the dependence on the operator’s declaration. The new collar design reduces effect of poison rods considerably. Instead of 12 pins of 5.2% Gd causing a 20.4% effect, as in the standard thermal mode collar, they only cause a 3.2% effect in the new collar. However it has higher efficiency so that reasonably precise measurements can be made in 25 minutes, rather than the 1 hour of previous collars. The new collar is fully compatible with the use of the standard data collection and analysis code INCC. This report describes the calibration that was made with a mock-up assembly at Los Alamos National Laboratory and with actual assemblies at the AREVA Fuel fabrication Plant in Lingen, Germany.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TH-C-18A-05: Characteristics and Accuracy of CT Radiation Profile Width Measurements Using Radiochromic Films

Purpose: To investigate the impact of several acquisition and image analysis factors on the accuracy of CT beam width measurement using Gafchromic XR-QA2 film and an off the shelf document scanner. Methods: The film was carefully placed at the iso-center and exposed at various x-ray beam energies (80–140 kVp), exposure levels (50–400 mAs), and nominal beam widths (1.25, 5, and 10 mm). Films were scanned on a RICOH MP3501 flat-bed document scanner using reflection mode and various spatial resolutions (100 to 600 dpi) and locations within the scanner bed. Radiation dose profiles were derived by converting the net reflection measurements to dose values (in mGy) through film calibration (which is also described here). The beam widths were characterized by the FWHM and FWTM of the dose profiles and the deviations from the hybrid reference standards were quantified. The impact of x-ray beam energy, exposure intensity, film calibration, and the uniformity and spatial resolution of the document scanner were investigated. Results: The uncertainties in both FWHM and FWTM caused by varying beam energy, exposure level, and scanner uniformity were all within approximately 5%. Increasing scanner spatial resolution increased the uncertainty in both FWHM and FWTM (R2 = 0.35–0.71), with the FWTM affected by more than five times than the FWHM (28% vs. 4.9%). When uncalibrated dose profiles were used, the FWHM and FWTM were over-estimated by as much as 11.6% and 7.6%, respectively. Narrower beam width was more sensitive to the film calibration than the wider one (R2 = 0.68 and 0.85 for the FWHM and FWTM, respectively). Conclusion: Measurement of CT beam width using Gafchromic XR-QA2 films is robust against x-ray energy, exposure level, and scanner uniformity. It can provide adequate accuracy for all practical purposes with appropriate film calibration and scanner spatial resolution (100 dpi or less)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroradiometric calibration of the Thematic Mapper and multispectral scanner system

The eleventh quarterly report on Spectroradiometric Calibration of the Thematic Mapper (Contract NAS5-27832) discusses calibrations made at White Sands on 24 May 1985. An attempt is made to standardize test results. Critical values used in the final steps of the data reduction and the comparison of the results of the pre-flight and internal calibration (IC) data are summarized.

Slater, P. N.↗

UV/VUV radiometric calibrations at SURF II

Since 1981 more than 150 instrument calibrations have been performed on the radiometric instrumentation calibration beamline at the Synchrotron Ultraviolet Radiation Facility (SURF II) at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland. This 300 MeV electron storage ring operates routinely at electron currents greater than 250 mA. The spectrometer calibration beamline provides a continuum of radiation from 4 nm through the visual spectral region in the form of an intense beam with total angular divergence of 1.2 mrad. The probable uncertainty for the flux ranges from about 5 percent at 4 nm to less than 2 percent above 20 nm. The new system will radiometrically trace to SURF II, and thus is expected to reduce the calibration uncertainty for diodes in this region by a factor of five to the 1-2 percent level.

Furst, Mitchell L.↗

SEASAT SAR performance evaluation study

The performance of the SEASAT synthetic aperture radar (SAR) sensor was evaluated using data processed by the MDA digital processor. Two particular aspects are considered the location accuracy of image data, and the calibration of the measured backscatter amplitude of a set of corner reflectors. The image location accuracy was assessed by selecting identifiable targets in several scenes, converting their image location to UTM coordinates, and comparing the results to map sheets. The error standard deviation is measured to be approximately 30 meters. The amplitude was calibrated by measuring the responses of the Goldstone corner reflector array and comparing the results to theoretical values. A linear regression of the measured against theoretical values results in a slope of 0.954 with a correlation coefficient of 0.970.

Source record↗

Physically Motivated Deep Learning to Superresolve and Cross Calibrate Solar Magnetograms

Abstract Superresolution (SR) aims to increase the resolution of images by recovering detail. Compared to standard interpolation, deep learning-based approaches learn features and their relationships to leverage prior knowledge of what low-resolution patterns look like in higher resolution. Deep neural networks can also perform image cross-calibration by learning the systematic properties of the target images. While SR for natural images aims to create perceptually convincing results, SR of scientific data requires careful quantitative evaluation. In this work, we demonstrate that deep learning can increase the resolution and calibrate solar imagers belonging to different instrumental generations. We convert solar magnetic field images taken by the Michelson Doppler Imager (resolution ∼2″ pixel −1 ; space based) and the Global Oscillation Network Group (resolution ∼2.″5 pixel −1 ; ground based) to the characteristics of the Helioseismic and Magnetic Imager (resolution ∼0.″5 pixel −1 ; space based). We also establish a set of performance measurements to benchmark deep-learning-based SR and calibration for scientific applications.

Muñoz-Jaramillo, Andrés (ORCID:0000000247160840)↗

Performance Assessment of Different Pulse Reconstruction Algorithms for the ATHENA X-Ray Integral Field Unit

The X-ray Integral Field Unit (X-IFU) microcalorimeter, on-board Athena, with its focal plane comprising 3840 Transition Edge Sensors (TESs) operating at 90 mK, will provide unprecedented spectral-imaging capability in the 0.2-12 keV energy range. It will rely on the on-board digital processing of current pulses induced by the heat deposited in the TES absorber, as to recover the energy of each individual events. Assessing the capabilities of the pulse reconstruction is required to understand the overall scientific performance of the X-IFU, notably in terms of energy resolution degradation with both increasing energies and count rates. Using synthetic data streams generated by the X-IFU End-to-End simulator, we present here a comprehensive benchmark of various pulse reconstruction techniques, ranging from standard optimal filtering to more advanced algorithms based on noise covariance matrices. Beside deriving the spectral resolution achieved by the different algorithms, a first assessment of the computing power and ground calibration needs is presented. Overall, all methods show similar performances, with the reconstruction based on noise covariance matrices showing the best improvement with respect to the standard optimal filtering technique. Due to prohibitive calibration needs, this method might however not be applicable to the X-IFU and the best compromise currently appears to be the so-called resistance space analysis which also features very promising high count rate capabilities.

microcalorimeters↗

THE RELATIVE INTENSITY CALIBRATION OF HINODE/EIS AND SOHO/SUMER

In this work, we have used simultaneous observations of the quiet Sun above the solar west limb obtained with the Hinode/Extreme ultraviolet Imaging Spectrograph and SOHO/SUMER instruments to determine their relative intensity calibration. We used two different methods: intensity ratios of lines emitted by the same upper level and observed in the spectral ranges of the two spectrometers, and the determination of the differential emission measure and total emission measure of the plasma. We review the uncertainties in our analysis and conclude that the relative calibration of the two instruments, as it can be determined from the standard data reduction software of each of them, is correct within uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the World Infrared Standard Group Field Campaign Report

The standard to which broadband infrared irradiance radiometers (pyrgeometers) are compared is called the World Infrared Standard Group (WISG), maintained in Davos, Switzerland, at the World Radiation Center. WISG consists of four pyrgeometers that were calibrated using the absolute sky-scanning radiometer (ASR; Philipona 2001). The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) user facility has recently adopted this as its standard and all Eppley precision infrared radiometer (PIR) pyrgeometers in ARM are currently being calibrated by transfer calibrations from WISG. Subsequently, the ASR has fallen out of operation, Julian Gröbner (2012) developed the infrared integrating sphere (IRIS) radiometer, and Ibrahim Reda (2012) developed the absolute cavity pyrgeometer (ACP). The IRIS and ACP make absolute measurements of broadband downwelling infrared irradiance using different approaches. These two instruments have been compared to each other and to the WISG (Gröbner et al. 2014). The two newer instruments agreed within about 1 Wm-2 with each other, but not with the WISG, which was 2-5 Wm-2 lower depending on the column water vapor loading. Consequently, a case for changing the current WISG has been made by Gröbner and Reda, basing their suggestion on a total of nine hours of simultaneous IRIS and ACP comparison data as well as data from 177 clear-sky nights between the IRIS and WISG radiometers from October 2009 to December 2013 (Gröbner et al. 2014). These findings were later confirmed during the second International Pyrgeometer Comparison (IPgC-II) held in September/October 2015 at Physikalisch-Meteorologisches Observatorium Davos (PMOD)/World Radiation Center (WRC), bringing the total to about 20 hours of simultaneous ACP and IRIS measurements spread across two years and five days, in the mountainous environment of Davos. For this campaign, the WISG evaluation team deployed several instruments for absolute infrared radiation measurements and pyrgeometers that have been tied to the original standard (ASR) to ARM’s Southern Great Plains (SGP) atmospheric observatory in the fall of 2017. The experiment was carried out in two phases in order to increase the probability of collecting measurements at a range of water vapor column values, to which the measurements have shown some dependence. Phase 1 of the deployment ran from October 15 to 28, and Phase 2 ran from November 26 to December 9. Four redundant IRIS and two redundant ACP made coincident measurements during this time (the ASR no longer being available for comparison). The link to the WISG was provided by two pyrgeometers calibrated relative to the WISG prior to the campaign at SGP and also measuring coincidently with the two absolute radiometers. In addition, three of the original pyrgeometers directly tied to the original ASR were deployed. (See Figure 1 for instrument setup.) The experiment took place in the fall when water vapor columns were expected to range below and above the 1-cm level that is crucial for ferreting out the water vapor dependence of these measurements that has been noted in Gröbner et al. 2014 and other measurements. An additional source of longwave radiation flux observations was provided by the atmospheric emitted radiance interferometer (AERI). The AERI measures downwelling spectral radiance from 3.3 to 19 μm with a calibration that is better than 1% of the ambient radiance (Knuteson et al. 2004), and so serves as a potential source of evaluation for the WISG. The AERI’s field of view is 2 degrees, and is directed towards zenith. Earlier ARM projects led by Tony Clough as part of the Broadband Heating Rate Profile (BBHRP) effort demonstrated how to derive longwave flux from these zenith radiance observations.

AERI, instrument calibration, Southern Great Plain↗