Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Methods to estimate the transfer of contaminants into recycling products – A case study from Austria

Highlights: • Recycling of waste materials includes the risk of recycling hazardous substances. • Comparison of contaminants in recycling products to primary products and check of compliance with limit values. • Evaluation matrix to quickly scan the environmental and health risks of wastes for recycling. • Optimised sorting and quality control systems prevent transfer of contaminants into product cycles. - Abstract: Recycling of waste materials is desirable to reduce the consumption of limited primary resources, but also includes the risk of recycling unwanted, hazardous substances. In Austria, the legal framework demands secondary products must not present a higher risk than comparable products derived from primary resources. However, the act provides no definition on how to assess this risk potential. This paper describes the development of different quantitative and qualitative methods to estimate the transfer of contaminants in recycling processes. The quantitative methods comprise the comparison of concentrations of harmful substances in recycling products to corresponding primary products and to existing limit values. The developed evaluation matrix, which considers further aspects, allows for the assessment of the qualitative risk potential. The results show that, depending on the assessed waste fraction, particular contaminants can be critical. Their concentrations were higher than in comparable primary materials and did not comply with existing limit values. On the other hand, the results show that a long-term, well-established quality control system can assure compliance with the limit values. The results of the qualitative assessment obtained with the evaluation matrix support the results of the quantitative assessment. Therefore, the evaluation matrix can be suitable to quickly screen waste streams used for recycling to estimate their potential environmental and health risks. To prevent the transfer of contaminants into product cycles, improved data of relevant substances in secondary resources are necessary. In addition, regulations for material recycling are required to assure adequate quality control measures, including limit values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System and method for determining stator winding resistance in an AC motor using motor drives

A system and method for determining the stator winding resistance of AC motors is provided. The system includes an AC motor drive having an input connectable to an AC source and an output connectable to an input terminal of an AC motor, a pulse width modulation (PWM) converter having switches therein to control current flow and terminal voltages in the AC motor, and a control system connected to the PWM converter. The control system generates a command signal to cause the PWM converter to control an output of the AC motor drive corresponding to an input to the AC motor, selectively generates a modified command signal to cause the PWM converter to inject a DC signal into the output of the AC motor drive, and determines a stator winding resistance of the AC motor based on the DC signal of at least one of the voltage and current.

42 ENGINEERING↗

Cyber-Physical System Security With Deceptive Virtual Hosts for Industrial Control Networks

A challenge facing industrial control network administrators is protecting the typically large number of connected assets for which they are responsible. These cyber devices may be tightly coupled with the physical processes they control and human induced failures risk dire real-world consequences. Dynamic virtual honeypots are effective tools for observing and attracting network intruder activity. This paper presents a design and implementation for self-configuring honeypots that passively examine control system network traffic and actively adapt to the observed environment. In contrast to prior work in the field, six tools were analyzed for suitability of network entity information gathering. Ettercap, an established network security tool not commonly used in this capacity, outperformed the other tools and was chosen for implementation. Utilizing Ettercap XML output, a novel four-step algorithm was developed for autonomous creation and update of a Honeyd configuration. This algorithm was tested on an existing small campus grid and sensor network by execution of a collaborative usage scenario. Automatically created virtual hosts were deployed in concert with an anomaly behavior (AB) system in an attack scenario. Virtual hosts were automatically configured with unique emulated network stack behaviors for 92% of the targeted devices. The AB system alerted on 100% of the monitored emulated devices.

97 MATHEMATICS AND COMPUTING↗

MPCPy: An Open-Source Software Platform for Model Predictive Control in Buildings

Within the last decade, needs for building control systems that reduce cost, energy, or peak demand, and that facilitate building-grid integration, district-energy system optimization, and occupant interaction, while maintaining thermal comfort and indoor air quality, have come about. Current PID and schedule-based control systems are not capable of fulfilling these needs, while Model Predictive Control (MPC) could. Despite the critical role MPC-enabled buildings can play in future energy infrastructures, widespread adoption of MPC within the building industry has yet to occur. To address barriers associated with system setup and configuration, this paper introduces an open-source software platform that emphasizes use of self-tuning adaptive models, usability by non-experts of MPC, and a flexible architecture that enables application across projects.

Blum, David↗

SolarPlus Optimizer: Integrated Control of Solar, Batteries, and Flexible Loads for Small Commercial Buildings

Building-level microgrids may be a key strategy to unlock the combined potential of flexible loads, renewable generation, and energy storage. However, few software options exist for integrated control of building loads and other distributed energy resources at this scale. The commercial software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice. The SolarPlus Optimizer (SPO) is an open-source building-level microgrid control platform that uses Model Predictive Control to optimize both building loads and behind-the-meter energy storage to reduce energy bills and increase demand flexibility. This paper evaluates the capabilities of SPO in a small commercial building in Northern California under multiple electricity tariffs and demand response scenarios. Comparing SPO operation with an emulated battery and baseline operation employing a commercial optimization service, SPO reduced electricity bills by an estimated 7.3% in summer, 3.2% in spring, and 3.7% in winter. In a “load shape” scenario meant to counter the “duck curve”, SPO achieved 71% fewer violations from the load signal than the baseline control method. During a three hour long load shed event, SPO reduced cooling and refrigeration load by 38%. This research shows significant potential to provide load flexibility for building-level microgrids for this type of control systems. Finally, the paper discusses the future direction of research on open-source control systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identifying Adversarial Cyber-Activity in Operational Technology Environments Using Bayesian Networks

Critical infrastructure and other operational technology (OT) environments face increasing cybersecurity risks from adversarial behavior. This paper describes the development of a risk model using a Bayesian network to enhance the comprehension of observable cyber events caused by malicious activity in OT environments. The core of the Bayesian network is a process model that describes the stages of adversary behavior. The remainder of the model is based on the MITRE ATT&CK® for Industrial Control Systems (ICS) taxonomy, which includes tactics and techniques that may be used by the adversary. The observables provide evidence for adversary behavior through the intermediary technique and tactic nodes. One challenge in constructing this model is a lack of open-source data from cyber-attacks on OT systems. This paper discusses learning from limited data, the elicitation of expert opinion to construct the conditional probability tables when data is scarce, and the refinement of the most difficult conditional probabilities tables using several forms of sensitivity analyses. Finally, the Bayesian network is demonstrated using two historical case studies: the DarkSide ransomware attack on the Colonial Pipeline and the destructive cyberattack targeting the ThyssenKrupp blast furnace. Index Terms—Cybersecurity, industrial control systems, operational technology

97 - MATHEMATICS AND COMPUTING↗

Passivity analysis for a winged re-entry vehicle

Application of simple adaptive control (SAC) theory to the design of guidance and control systems for winged re-entry vehicles has been proven successful. To apply SAC to these non-linear and non-stationary systems, it needs to be Almost Strictly Passive (ASP), which is an extension of the Almost Strictly Positive Real (ASPR) condition for linear, time-invariant systems. To fulfill the ASP condition, the controlled, non-linear system has to be minimum-phase (i.e., the zero dynamics is stable), and there is a specific condition for the product of output and input matrix. Earlier studies indicate that even the linearised system is not ASPR. The two problems at hand are: 1) the system is non-minimum phase when flying with zero bank angle, and 2) whenever there is hybrid control, e.g., yaw control is established by combined reaction and aerodynamic control for the major part of flight, the second ASPR condition cannot be met. In this paper we look at both issues, the former related to the guidance system and the latter to the attitude-control system. It is concluded that whenever the nominal bank angle is zero, the passivity conditions can never be met, and guidance should be based on nominal commands and a redefinition of those whenever the error becomes too large. For the remaining part of the trajectory, the passivity conditions are marginally met, but it is proposed to add feedforward compensators to alleviate these conditions. The issue of hybrid control is avoided by redefining the controls with total control moments and adding a so-called control allocator. Deriving the passivity conditions for rotational motion, and evaluating these conditions along the trajectory shows that the (non-linear) winged entry vehicle is ASP. The sufficient conditions to apply SAC for attitude control are thus met.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mining Smart Meter Data to Enhance Distribution Grid Observability for Behind-the-Meter Load Control: Significantly improving system situational awareness and providing valuable insights

Distributed Energy Resources (DERs) are playing an increasingly important role in power systems. In 2023, five categories of DERs-distributed solar, electric vehicles (EVs), energy storage, residential smart thermostats, and small-scale combined heat and power-are expected to contribute about 104 GW to the U.S. summer peak (see GTM, 2018). With the increasing integration of DERs in power distribution systems, distributed load control is imperative to smooth the fluctuations that they introduce. However, a main challenge is that distribution systems lack systematic situational awareness because of their limited sensors. Furthermore, most customer-level behind-the-meter (BTM) DERs, such as rooftop photovoltaics (PVs), are being integrated into distribution systems, which complicates the system monitoring and control. Furthermore, enhanced electric grid monitoring is needed to promote renewable integration while ensuring reliability, but current approaches rely on expensive sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NSRL Extraction Bump Control in the Booster

Due to inadequacies in the user interface of the booster orbit control system, a number of new tools were developed. The first priority was an accurate calculation of the winding currents given specific displacements at each extraction septa. Next, the physical limits of the power supplies ({+-}600 amps) needed to be taken into account. In light of this limit, a system is developed that indicates to the user what the allowed values of one bump parameter are once the other two have been specified. Finally, techniques are developed to account for the orbit behavior once power supplies are requested to exceed their {+-}600 amp limit. This includes a recalculation of bump parameters and a calculation of the amplitude of the residuals. Following this, possible areas for further development are outlined. These techniques were computationally developed in Mathematica and tested in the Methodical Accelerator Design (MAD) program before they were implemented into the control system. At the end, a description of the implementation of these techniques in a new interface is described. This includes a depiction of the appearance and functionality of the graphical user interface, a description of the input and output flow, and an outline of how each important calculation is performed.

43 PARTICLE ACCELERATORS↗

Architecture for Co-Simulation of Transportation and Distribution Systems with Electric Vehicle Charging at Scale in the San Francisco Bay Area

This work describes the Grid-Enhanced, Mobility-Integrated Network Infrastructures for Extreme Fast Charging (GEMINI) architecture for the co-simulation of distribution and transportation systems to evaluate EV charging impacts on electric distribution systems of a large metropolitan area and the surrounding rural regions with high fidelity. The current co-simulation is applied to Oakland and Alameda, California, and in future work will be extended to the full San Francisco Bay Area. It uses the HELICS co-simulation framework to enable parallel instances of vetted grid and transportation software programs to interact at every model timestep, allowing high-fidelity simulations at a large scale. This enables not only the impacts of electrified transportation systems across a larger interconnected collection of distribution feeders to be evaluated, but also the feedbacks between the two systems, such as through control systems, to be captured and compared. The findings are that with moderate passenger EV adoption rates, inverter controls combined with some distribution system hardware upgrades can maintain grid voltages within ANSI C.84 range A limits of 0.95 to 1.05 p.u. without smart charging. However, EV charging control may be required for higher levels of charging or to reduce grid upgrades, and this will be explored in future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State space modeling of reactor core in a pressurized water reactor

The power control system of a nuclear reactor is the key system that ensures a safe operation for a nuclear power plant. However, a mathematical model of a nuclear power plant is in the form of nonlinear process and time dependent that give very hard to be described. One of the important components of a Pressurized Water Reactor is the Reactor core. The aim of this study is to analyze the performance of power produced from a reactor core using temperature of the moderator as an input. Mathematical representation of the state space model of the reactor core control system is presented and analyzed in this paper. The data and parameters are taken from a real time VVER-type Pressurized Water Reactor and will be verified using Matlab and Simulink. Based on the simulation conducted, the results show that the temperature of the moderator plays an important role in determining the power of reactor core.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

System and method for operator control of heterogeneous unmanned system teams

A control architecture and associated control methods are under development to allow a single user to control a team of multiple heterogeneous UMS as they conduct multi-faceted (i.e. multi-objective) missions in real time is disclosed. The control architecture is hierarchical, modular and layered and enables operator interaction at each layer, ensuring the human operator is in close control of the unmanned team at all times. The architecture and key data structures are introduced. Two approaches to distributed collaborative control of heterogeneous unmanned systems are described, including an extension of homogeneous swarm control and a novel application of distributed model predictive control. Initial results are presented, demonstrating heterogeneous UMS teams conducting collaborative missions.

47 OTHER INSTRUMENTATION↗

April Burn-in Testing Report for Genentech B35, South San Francisco Campus

Genentech and Webcor reserved a thirty-day “burn-in” period after completion of the commissioning phase to conduct a detailed evaluation of all systems in the new HTA B35 building prior to occupancy. During this period, LBNL evaluated the automated shading and dimmable indoor lighting control systems to determine whether the systems were working according to design intent. LBNL also evaluated lighting energy use and visual and thermal comfort in the perimeter zones. LBNL conducted the monitored evaluation in four perimeter zones on the 7th floor from March 25th to May 7th, 2015. The daylight and tuning control functions of the dimmable LED direct-indirect lighting control system were evaluated and then adjusted in collaboration with the electrical contractor (Redwood Electric) during the first three weeks of the evaluation. The lighting controls were then considered to be operating as expected after April 20th and a detailed evaluation of control performance and energy use was conducted thereafter. The automated shading system was assessed over a limited period (April 15-30) on both the 6th and 7th floors to determine whether the controls raised the shade when discomfort glare was imperceptible. After a few days of analysis, changes were made to the settings to admit more daylight by changing both the glare sensor threshold and by increasing the depth of direct sun ingress from 36” to 48” from the façade on all orientations except the east.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Photocatalysis for the Reduction of CO 2 through Non-covalent Supramolecular Assembly

Here, we report the first successful enhancement of photocatalytic performance by introduction of hydrogen bonding interactions to Re bipyridine catalyst and Ru photosensitizer system (ReDAC/RuDAC) with the addition of amide substituents. This system shows a more than threefold increase in turnover number (TONCO = 100 ± 4) and quantum yield (Φ CO = 23 ± 1 %) for carbon monoxide formation compared to the control system using unsubstituted Ru photosensitizer (RuBPY) and ReDAC (TON CO = 28 ± 4 and Φ CO = 7 ± 1 %) in acetonitrile (MeCN) with BIH as sacrificial reductant. In dimethylformamide (DMF), a hydrogen bonding interrupting solvent, the ReDAC/RuDAC system showed a decrease in catalysis while the control system exhibited an increase, indicating the role of hydrogen bonding in enhancing the photocatalysis for CO 2 reduction through supramolecular assembly. RuDAC and RuBPY have demonstrated no significant differences in lifetime measurements, spectroscopic analysis, electrochemical studies and spectroelectrochemical studies, revealing that the enhancement in photocatalysis in RuDAC/ReDAC in MeCN system is not due to differences in properties unrelated to catalyst/photosensitizer association but a direct result of hydrogen bonding interactions.

14 SOLAR ENERGY↗

Single-Phase On-Board Bidirectional PEV Charger for V2G Reactive Power Operation

This paper presents the design and implementation of a single-phase on-board bidirectional plug-in electric vehicle (PEV) charger that can provide reactive power support to the utility grid in addition to charging the vehicle battery. The topology consists of two-stages: a full-bridge ac-dc boost converter; and a half-bridge bidirectional dc-dc converter. The charger operates in two quadrants in the active-reactive power (PQ) power plane with five different operation modes (i.e., charging-only, charging-capacitive, charging-inductive, capacitive-only, and inductive-only). This paper also presents a unified controller to follow utility PQ commands in a smart grid environment. The cascaded two-stage system controller receives active and reactive power commands from the grid, and results in line current and battery charging current references while also providing a stable dynamic response. The vehicle's battery is not affected during reactive power operation in any of the operation modes. Finally, testing the unified system controller with a 1.44 kVA experimental charger design demonstrates the successful implementation of reactive power support functionality of PEVs for future smart grid applications.

battery charger↗

Bridging the Gap Between Modern UX Design and Particle Accelerator Control Room Interfaces

Accelerator control systems often represent relatively complex and safety-sensitive human-machine interfaces within process control industries. These systems are technically robust and reflect the cumulative integration of solutions built and adapted across decades. One of the regular, unfortunate casualties of provisional accelerator control system updates is their human-system interfaces (HSIs) which often lag behind modern usability and design standards. An additional challenge is that although there is a multitude of established human factors (HF), and user experience (UX) principles for everyday digital applications, there are very few (if any) established principles for complex and safety-critical applications for an accelerator. This paper argues for the importance of established HF and UX principles (herein referred to as human-centered design principles) into the development of accelerator HSIs, emphasizing the need for clarity, consistency, responsiveness, and cognitive accessibility. Drawing from HF/UX best practices and human-centered design, this paper discusses how these approaches can enhance operator performance, reduce human error, and improve accelerator personnel collaboration. Case studies from Accelerator Control Operations Research Network (ACORN) at Fermilab are explored to demonstrate how interfaces built with human-centered design principles can scale with system complexity while remaining intuitive and efficient for diverse user roles including operators, machine experts, and engineers. By bridging the gap between traditional control system design and modern human-centered design methods, this paper provides a roadmap for evolving accelerator HSIs into more usable, maintainable, and effective tools.

Hill, Rachael [Idaho Natl. Lab.]↗

National Ignition Facility Control and Information System Operational Tools

The National Ignition Facility (NIF) in Livermore, California, is the world's highest-energy laser fusion system and one of the premier large scale scientific projects in the United States. The system is designed to setup and fire a laser shot to a fusion ignition or high energy density target at rates up to a shot every 4 hours. NIF has 192 laser beams delivering up to 1.8 MJ of energy to a {approx}2 mm target that is planned to produce >100 billion atm of pressure and temperatures of >100 million degrees centigrade. NIF is housed in a ten-story building footprint the size of three football fields as shown in Fig. 1. Commissioning was recently completed and NIF will be formally dedicated at Lawrence Livermore National Laboratory on May 29, 2009. The control system has 60,000 hardware controls points and employs 2 million lines of control system code. The control room has highly automated equipment setup prior to firing laser system shots. This automation has a data driven implementation that is conducive to dynamic modification and optimization depending on the shot goals defined by the end user experimenters. NIF has extensive facility machine history and infrastructure maintenance workflow tools both under development and deployed. An extensive operational tools suite has been developed to support facility operations including experimental shot setup, machine readiness, machine health and safety, and machine history. The following paragraphs discuss the current state and future upgrades to these four categories of operational tools.

42 ENGINEERING↗

Keras2c: A library for converting Keras neural networks to real-time compatible C

With the growth of machine learning models and neural networks in measurement and control systems comes the need to deploy these models in a way that is compatible with existing systems. Existing options for deploying neural networks either introduce very high latency, require expensive and time consuming work to integrate into existing code bases, or only support a very limited subset of model types. We have therefore developed a new method called Keras2c, which is a simple library for converting Keras/TensorFlow neural network models into real-time compatible C code. It supports a wide range of Keras layers and model types including multidimensional convolutions, recurrent layers, multi-input/output models, and shared layers. Keras2c re-implements the core components of Keras/TensorFlow required for predictive forward passes through neural networks in pure C, relying only on standard library functions considered safe for real-time use. The core functionality consists of ~ 1500 lines of code, making it lightweight and easy to integrate into existing codebases. Keras2c has been successfully tested in experiments and is currently in use on the plasma control system at the DIII-D National Fusion Facility at General Atomics in San Diego.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗