Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design Parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Is Radioactive Tank Waste a Bingham Fluid?

Slurries and sludges across the United States Department of Energy (DOE) complex rank among the most rheologically interesting. Their composition is heterogeneous, spanning a very broad range of particle sizes, densities, and interparticle forces. All exhibit shear thinning, some have yield stresses, and many are thixotropic. Despite the variety, these complex fluids are often represented using the historic Bingham fluid model, which fits higher shear rate data to a simple straight line. The intercept provides a yield stress, which has been a key design parameter in construction of large-scale waste processing facilities. However, many radioactive wastes are simply not Bingham fluids, which extrapolate but poorly across low to intermediate shear rates that are characteristic of typical processing conditions. Indeed, processing shear rates as high as 200 1/s, which has been a typical minimum shear rate used in fitting, are seldom encountered in nuclear waste processing. Therefore, more realistic rheological models are necessary to accurately predict waste processing performance. PNNL recently re-evaluated the rheology of reconstituted Hanford REDOX sludge waste against a wide variety of rheological models including the Bingham, Cross, Cross with yield stress, Carreau, biviscous, Herschel-Bulkley (which includes a power law dependence), Casson, and Gay models. They found that all of the models provided a closer fit than the Bingham model and that the biviscous model and Cross with yield stress model were convincing. However, reconstituted Hanford REDOX sludge waste is but one type of DOE waste and a direct contrast and comparison of these three models against undiluted, unmixed tank waste (actual not simulant) has not been performed previously. Therefore, the purpose of this paper is to evaluate the rheology of actual tank waste with these more accurate rheological models. In this paper, we evaluate select rheological data for slurry samples from Hanford’s AZ-101, AZ-102, and SY-101 waste tanks. In each of these cases, we find that Cross’ model with yield stress and the biviscous model significantly outperform the Bingham fluid model. Furthermore, the AZ-101 data also shows that the shear stress peak that startup significantly exceeds the Bingham yield stress, which is commonly observed in the incipient moments of rheological measurements on simulants. In contrast, Cross’ model may empirically accommodate an initial spike in shear stress at modest shear rates. These are important observations because computational and analytical fluid dynamics simulations rely on rheological constitutive models for accurately and conservatively predict waste processing performance. These findings suggest the need for better rheological modeling of and validation against radioactive waste.

Rheology, Radioactive Waste↗

Effect of Thermal Expansion Coefficient, Viscosity and Melting Range in Simulation of PCM Embedded Heat Exchangers With and Without Fins

Phase change material heat exchangers (PCMHX) have an important role in integrating renewable energy systems. PCMHX can offer high storage density at various temperatures of interest and can be used for grid load shifting purposes. Numerical models enable engineers to estimate PCMHX performance for different design parameters and operating conditions. Modeling phase change phenomena is challenging due to the complex time-dependent nature of the process. The accuracy of models is highly sensitive to PCM thermo-physical properties. Thermal expansion coefficient (β), viscosity (μ) and melting temperature range (MR) of a PCM are important properties, especially when natural convection is not negligible. In PCMHX modeling, using less than accurate values for these properties can have significant impact on the simulation outcomes. These properties and discussions thereof are not readily available in the literature. This paper presents a brief review of the literature and a numerical study investigating the model sensitivity to the above-mentioned properties for PCMHX with and without fins. CFD is used to evaluate the charging (melting) phenomena. The study quantifies the impact of uncertainty in these properties on the melting rate and temperature profile. Constant wall temperature was considered as heat source with no heat loss to ambient. Here, the results show that β and μ has significant effect on the melting rate and evolution of the melting front. For a non-finned domain when comparing results for different published values of β and μ, the deviation in melting time can be up to 12.9% and 57.6% respectively. For high wall temperatures, change in melting range did not impact melting time. But when the wall temperature is reduced, up to 9.8% deviation in melting time is observed.

CFD↗

Influence on Structural Loading of a Wave Energy Converter by Controlling Variable-Geometry Components and the Power Take-Off

Oceans are harsh environments and can impose significant loads on deployed structures. The deployment of wave energy converters (WECs) faces a design challenge with apparently contradictory goals. A WEC should be designed to maximize the energy absorbed while ensuring the operating wave condition does not exceed the failure limits of the device itself. Therefore, the loads endured by the support structure are a design constraint for the system. Adaptability to different sea states is, therefore, highly desirable. This work uses a WEC-Sim model of a variable-geometry oscillating wave energy converter (VGOSWEC) mounted on a support structure simulated under different wave scenarios. A VGOSWEC resembles a paddle pitching about a fixed hinge perpendicular to the incoming wave fronts. Therefore, the hinge experiences loads perpendicular to its axis as it maintains its position. The geometry of the VGOSWEC is varied by opening a series of controllable flaps on the pitching paddle when the structure experiences threshold loads. Because opening the flaps lets the waves transmit through the paddle, it is hypothesized that opening the flaps should result in load shedding at the base of the support structure. The load shedding is achieved by reducing the moments about the hinge axis. This work compares the hydrodynamic coefficients, natural periods, and response amplitude operators from completely closed to completely open configurations of the controllable flaps. The comparisons quantify the effects of letting the waves transmit through the VGOSWEC. This work shows that the completely open configuration can reduce the pitch and surge loads on the base of the support structure by as much as 80%. It was observed that at the paddle's resonance frequency, the loads on the structure increased substantially. This increase in loads can be mitigated by a rotational power take-off damping about the hinge axis. Changing the rotational power take-off damping was identified as an additional design parameter that can be used to control the loads experienced by the WEC's support structure.

fixed and floating structures↗

Optimization of three-dimensional metamaterials for terahertz energy harvesting

This work focuses on finite element modeling (FEM) of a three-dimensional metamaterial used as an absorber for terahertz energy harvesting. The metamaterial consists of patterned pillars of an SU-8 dielectric photoresist coupled to a copper metal overlayer. Here, our study shows that the electromagnetic performance of the metamaterial is dependent on the following characteristic design parameters of the SU-8 dielectric: pillar height, bottom side length, and spacing between adjacent pillars. Using FEM, the metamaterial geometry is successfully optimized and the surface plasmon can be tuned to a peak frequency of 1.2 THz and a maximum terahertz absorption amplitude of 30%.

36 MATERIALS SCIENCE↗

Wafer-scale high-k SrTiO 3 dielectrics with rational barrier-layer design for low leakage and high charge density

High-k oxides such as SrTiO 3 promise large capacitance, but their dielectric response is often limited by leakage currents due to reduced bandgaps. We show that introducing a thin barrier layer beneath SrTiO 3 is a simple and effective way to suppress leakage and increase charge density. Using hybrid molecular beam epitaxy, we grew uniform SrTiO 3 films on Nb:SrTiO 3 , CaSnO 3 /Nb:SrTiO 3 , and 2-in. SiO 2 /p-Si stacks to directly compare how different barrier layers influence device behavior. Both CaSnO 3 and SiO 2 reduce leakage, but the ultra-wide-bandgap SiO 2 layer enables much higher operating voltages, yielding charge densities exceeding 5 × 10 13 cm −2 at room temperature—more than a fivefold enhancement compared to devices without a barrier layer. This improvement comes with a predictable trade-off: the lower dielectric constant of SiO 2 reduces overall capacitance, making its thickness an important design parameter. Together, these results demonstrate that rational barrier-layer engineering—including wafer-scale integration on Si—provides a clear pathway to achieving higher charge densities in SrTiO 3 -based dielectric devices.

36 MATERIALS SCIENCE↗

Prompt Neutron Multiplicity Measurements with Portable Detectors

Mobile detection of kilogram quantities of special nuclear materials (SNM) during maritime transportation is a challenging problem for the U.S. Department of Homeland Security. Counting neutrons emitted by the SNM and partitioning them from background neutrons of multiple origins is the most effective passive means of detecting the SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment is complex due to the presence of spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. This work studied the possibilities of building a prototype neutron detector using boron- 10 (10B) as the converter in a novel form factor called “straws” that would address the above problem by examining multiplicity distributions of neutrons originating from a fissioning source. Currently, commercially manufactured fission meters (FM) are available that separate cosmic neutrons from non-cosmic neutrons and quantitatively determine the strength of a fissioning source; however, these FMs use 3He, which is becoming increasingly difficult to procure; also the size and weight of a commercial FM is not conducive to manual neutron detection operations in a maritime environment. The current project may provide a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to the FM. The prototype detector provides a large-area, efficient, lightweight, more granular neutron responsive detection surface (to facilitate imaging) to ease the application of the new FMs. A novel prototype fission meter is being designed at National Security Technologies, LLC, using a thin uniform coating of 10B as neutron converter (only 1 micron thick) inside a large array of thin (4 mm diameter) copper tubes. The copper tubes are only 2-mil thick, and each holds the stretched anode wire under tension and high voltage. The tubes are filled with proportional counter gas (a mixture of 90% Ar and 10% CO2). The tubes operate in proportional counter mode and attract mobile charged particles (alpha-particles) created in the nuclear interaction 10B(n, a)7Li. Several MCNPX calculations covering the substantial design parameter space of neutron multiplicity detectors have been performed and are presented. Our detector’s thermal neutron detection efficiency is compared to two Ortec commercial products, the Fission Meter and Detective-EX. Pulse height spectra originating from the charged particles created in the nuclear reaction 10B(n, a) 7Li* + 2.310 MeV (94%) – excited state (1) and 10B(n, a) 7Li + 2.792 MeV (6%) – ground state (2) are examined, and the response to incident gamma rays are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effective point of measurement of thimble ion chambers in megavoltage photon beams

Purpose: Determine the effective point of measurement (EPOM) of 12 thimble ion chambers, including miniature chambers and three models widely used for clinical reference dosimetry. The EPOM is the point at which the measured dose would arise in the measurement medium in the absence of the probe: For cylindrical chambers, it is shifted upstream relative to the central axis of the chamber. Although current dosimetry protocols prescribe a blanket upstream EPOM shift of 0.6r, with r as the chamber cavity radius, it has been shown in recent years that the EPOM does, in fact, depend on every detail of the chamber design and on the beam characteristics. In the wake of this finding, the authors undertake a comprehensive study of the EPOM for a series of chambers in water. Methods: This work relies on EGSnrc Monte Carlo calculations for the central axis depth dose in a water phantom and in ion chambers. They use a full Elekta Precise linac treatment head simulation to generate realistic photon beams with nominal energies of 6 and 25 MV and fields sizes of 10x10 and 40x40 cm{sup 2}. The correct EPOM shift for the 12 ion chambers, modeled in realistic detail, is taken as the one minimizing the deviation of the ratio between the dose to water and the dose to the gas of the chamber cavity, according to a method proposed and validated in previous work. Results: The analysis reveals that the actual EPOM shift is significantly smaller than the recommended value in current dosimetry protocols, by up to 25% for reference-class chambers and 80% for miniature chambers. The location of the EPOM also depends on the characteristics of the incident beam and varies in a well-defined way with the cavity length, the central electrode radius, and the thimble wall thickness. Conclusions: The authors confirm that an upstream EPOM shift of 0.6r is too large for thimble ion chambers in high energy photon beams. Proper values for the EPOM shift could be tabulated per beam and per chamber, but they envisage that a single shift for all practical beams may prove sufficient. Moreover, the systematic dependence on chamber characteristics provides evidence that a universal parametrization in terms of a few design parameters is conceivable and has implication for the calculation of chamber correction factors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fan-beam intensity modulated proton therapy

Purpose: This paper presents a concept for a proton therapy system capable of delivering intensity modulated proton therapy using a fan beam of protons. This system would allow present and future gantry-based facilities to deliver state-of-the-art proton therapy with the greater normal tissue sparing made possible by intensity modulation techniques.Methods: A method for producing a divergent fan beam of protons using a pair of electromagnetic quadrupoles is described and particle transport through the quadrupole doublet is simulated using a commercially available software package. To manipulate the fan beam of protons, a modulation device is developed. This modulator inserts or retracts acrylic leaves of varying thickness from subsections of the fan beam. Each subsection, or beam channel, creates what effectively becomes a beam spot within the fan area. Each channel is able to provide 0–255 mm of range shift for its associated beam spot, or stop the beam and act as an intensity modulator. Results of particle transport simulations through the quadrupole system are incorporated into the MCNPX Monte Carlo transport code along with a model of the range and intensity modulation device. Several design parameters were investigated and optimized, culminating in the ability to create topotherapy treatment plans using distal-edge tracking on both phantom and patient datasets.Results: Beam transport calculations show that a pair of electromagnetic quadrupoles can be used to create a divergent fan beam of 200 MeV protons over a distance of 2.1 m. The quadrupole lengths were 30 and 48 cm, respectively, with transverse field gradients less than 20 T/m, which is within the range of water-cooled magnets for the quadrupole radii used. MCNPX simulations of topotherapy treatment plans suggest that, when using the distal edge tracking delivery method, many delivery angles are more important than insisting on narrow beam channel widths in order to obtain conformal target coverage. Overall, the sharp distal falloff of a proton depth-dose distribution was found to provide sufficient control over the dose distribution to meet objectives, even with coarse lateral resolution and channel widths as large as 2 cm. Treatment plans on both phantom and patient data show that dose conformity suffers when treatments are delivered from less than approximately ten angles. Treatment time for a sample prostate delivery is estimated to be on the order of 10 min, and neutron production is estimated to be comparable to that found for existing collimated systems.Conclusions: Fan beam proton therapy is a method of delivering intensity modulated proton therapy which may be employed as an alternative to magnetic scanning systems. A fan beam of protons can be created by a set of quadrupole magnets and modified by a dual-purpose range and intensity modulator. This can be used to deliver inversely planned treatments, with spot intensities optimized to meet user defined dose objectives. Additionally, the ability of a fan beam delivery system to effectively treat multiple beam spots simultaneously may provide advantages as compared to spot scanning deliveries.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-18C-05: Characterization of a Silicon Strip Photon-Counting Detector in the Presence of Compton Scatter: A Simulation Study

Purpose: To investigate the effect of Compton scatter on detection efficiency and charge-sharing for a Si strip photon-counting detector as a function of pixel pitch, slice thickness and total pixel length. Methods: A CT imaging system employing a silicon photon-counting detector was implemented using the GATE Monte Carlo package. A focal spot size of 300 µm, magnification of 1.33, and pixel pitches of 0.1 and 0.5mm were initially investigated. A 60 kVp spectrum with 3 mm Al filter was used and energy spectral degradation based on a prototype detector was simulated. To study charge-sharing, a single pixel was illuminated, and the detector response in neighboring pixels was investigated. A longitudinally semiinfinite detector was simulated to optimize the quantum detection efficiency of the imaging system as a function of pixel pitch, slice thickness and depth of interaction. A 2.5 mm thick tungsten plate with a 0.01 mm by 1.5 mm slit was implemented to calculate the modulation transfer function (MTF) from projection-based images. A threshold of 15 keV was implemented in the detector simulation. The preliminary charge sharing investigation results considered only scattering effects and the detector electronics related factors were neglected. Results: Using a 15 keV threshold, 1% of the pixel charge migrated into neighboring pixels with a pixel size of 0.1×0.1 mm{sup 2}. The quantum detection efficiency was 77%, 84%, 87% and 89% for 15 mm, 22.5 mm, 30 mm, and 45 mm length silicon detector pixels, respectively. For a pixel pitch of 0.1 mm, the spatial frequency at 10% of the maximum MTF was found to be 5.2 lp/mm. This agreed with an experimental MTF measurement of 5.3 lp/mm with a similar detector configuration. Conclusion: Using optimized design parameters, Si strip photon-counting detectors can offer high detection efficiency and spatial resolution even in the presence of Compton scatter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-94: An Advanced Rotating Gamma Ray System for Stereotactic Radiosurgery

Purpose: Co-60 beams have unique dosimetric properties that are ideally suited for cranial treatments. Co-60 sources with cone-shaped collimators provide conformal dose distributions allowing for ablative treatments with rapid dose falloff to spare nearby critical structures. This work investigates a novel, image-guided, rotational Gamma ray system that provides both superior dose conformity/gradient and accurate stereotaxy for stereotactic radiosurgery (SRS). Methods: The SupeRay system (Cyber Medical Corp., China) consists of a rotating source chamber containing 30 gamma sources focusing at the isocenter with 4 collimators measuring 3, 4, 8 and 16mm in diameter. A novel switch design enables the 30 Gamma sources to be turned off at any arbitrarily selected 60° interval in order to avoid critical structures. The 3D treatment couch provides automatic treatment positioning between individual shots and the kV imaging system provides orthogonal images with a spatial resolution of 0.24mm to facilitate target localization. Monte Carlo simulations were used to compute dose distributions and compare with measurements and other Gamma ray SRS systems. Results: Monte Carlo results confirmed the SupeRay design parameters including output factors and 3D dose distributions. Its beam penumbra/dose gradient is similar to or slightly better than that of the Elekta Gamma Knife. The penumbra in the (x,y,z) direction was (7.38mm,7.38mm,3.86mm) for the 16mm collimator, (4.83mm,4.83mm,3.12mm) for the 8mm collimator, and (3.03mm,3.03mm,2.38mm) for the 4mm collimator, respectively, on the SupeRay system while it was (9.5mm,10.0mm,2.9mm), (4.3mm,4.3mm,2.9mm) and (3.2mm,3.2mm,1.9mm) for the same collimator sizes, respectively, on the Perfexion system. The kV imaging system together with a non-invasive relocatable frame provides accurate target localization (<0.5mm) for cases requiring multiple treatment fractions. Conclusion: Because of the unique dosimetric properties of Co-60 sources and its accurate stereotaxy/dose delivery, SupeRay is ideally suited for single and multiple-session ablative treatments of cranial lesions. This work was partially supported by Cyber Medical Corp.

60 APPLIED LIFE SCIENCES↗

SU-E-T-335: Dosimetric Investigation of An Advanced Rotating Gamma Ray System for Imaged Guided Radiation Therapy

Purpose: Co-60 beams have unique dosimetric properties for cranial treatments and thoracic cancers. The conventional concern about the high surface dose is overcome by modern system designs with rotational treatment techniques. This work investigates a novel rotational Gamma ray system for image-guided, external beam radiotherapy. Methods: The CybeRT system (Cyber Medical Corp., China) consists of a ring gantry with either one or two treatment heads containing a Gamma source and a multileaf collimator (MLC). The MLC has 60 paired leaves, and the maximum field size is either 40cmx40cm (40 pairs of 0.5cm central leaves, 20 pairs of 1cm outer leaves), or 22cmx40cm (32 pairs of 0.25cm central leaves, 28 pairs of 0.5cm outer leaves). The treatment head(s) can swing 35° superiorly and 8° inferiorly, allowing a total of 43° non-coplanar beam incident. The treatment couch provides 6-degrees-of-freedom motion compensation and the kV cone-beam CT system has a spatial resolution of 0.4mm. Monte Carlo simulations were used to compute dose distributions and compare with measurements. A retrospective study of 98 previously treated patients was performed to compare CybeRT with existing RT systems. Results: Monte Carlo results confirmed the CybeRT design parameters including output factors and 3D dose distributions. Its beam penumbra/dose gradient was similar to or better than that of 6MV photon beams and its isocenter accuracy is 0.3mm. Co-60 beams produce lower-energy secondary electrons that exhibit better dose properties in low-density lung tissues. Because of their rapid depth dose falloff, Co-60 beams are favorable for peripheral lung tumors with half-arc arrangements to spare the opposite lung and critical structures. Superior dose distributions were obtained for head and neck, breast, spine and lung tumors. Conclusion: Because of its accurate dose delivery and unique dosimetric properties of C-60 sources, CybeRT is ideally suited for advanced SBRT as well as conventional RT. This work was partially supported by Cyber Medical Corp.

60 APPLIED LIFE SCIENCES↗

SU-F-T-529: Dosimetric Investigation of a Rotating Gamma Ray System for ImagedGuided Modulated Arc Radiotherapy

Purpose: Because of their effectiveness and efficiency, rotational arc radiotherapy (MAT) techniques have been developed on both specialty machines such as Tomotherapy and conventional linear accelerators. This work investigates a new rotating Gamma therapy system for image guided MAT and SBRT of intra/extracranial tumors. Methods: The CyberMAT system (Cyber Medical Corp., China) consists of a ring gantry with a gamma source (effective source size 1cm and 1.7cm respectively), a 120-leaf MLC, a kV CBCT and an EPID. The treatment couch provides 6-degrees-of-freedom motion compensation and the kV CBCT system has a spatial resolution of 0.4mm for target localization. The maximum dose rate is >4.0 Gy/min and the maximum field size is 40cm × 40cm. Monte Carlo simulations were used to compute dose distributions and compare with measurements. A retrospective study of 125 previously treated SBRT patients was performed to evaluate the dosimetric characteristics of CyberMAT in comparison with existing VMAT systems. Results: Monte Carlo results confirmed the CyberMAT design parameters including output factors and 3D dose distributions. Its beam penumbra is 5mm to 10mm for field sizes 1cm to 10cm, respectively and its isocenter accuracy is <0.5mm. Compared to the 6 MV photons of Tomotherapy and conventional linacs, Cobalt beams produce lower-energy secondary electrons that exhibit better dose properties in low-density lung tissues. Cobalt beams are ideal for peripheral lung tumors with half-arc arrangements to spare the opposite lung and other critical structures. Superior dose distributions have been obtained for brain, head and neck, breast, spine and lung tumors with half/full arc arrangements. Conclusion: Because of the unique dosimetric properties of Cobalt sources and its accurate stereotaxy/dose delivery CyberMAT is ideally suited for image guided MAT and SBRT. Full-arc arrangements are superior for brain and H&N treatments while half-arc arrangements produce best dose distributions for thoracic tumors.

60 APPLIED LIFE SCIENCES↗

Intrinsically disordered proteins access a range of hysteretic phase separation behaviors

The phase separation behavior of intrinsically disordered proteins (IDPs) is thought of as analogous to that of polymers that undergo equilibrium lower or upper critical solution temperature (LCST and UCST, respectively) phase transition. This view, however, ignores possible nonequilibrium properties of protein assemblies. Here, by studying IDP polymers (IDPPs) composed of repeat motifs that encode LCST or UCST phase behavior, we discovered that IDPs can access a wide spectrum of nonequilibrium, hysteretic phase behaviors. Experimentally and through simulations, we show that hysteresis in IDPPs is tunable and that it emerges through increasingly stable interchain interactions in the insoluble phase. To explore the utility of hysteretic IDPPs, we engineer self-assembling nanostructures with tunable stability. These findings shine light on the rich phase separation behavior of IDPs and illustrate hysteresis as a design parameter to program nonequilibrium phase behavior in self-assembling materials.

59 BASIC BIOLOGICAL SCIENCES↗

Quantifying the topology of magnetic skyrmions in three dimensions

Magnetic skyrmions have so far been treated as two-dimensional spin structures characterized by a topological winding number. However, in real systems with the finite thickness of the device material being larger than the magnetic exchange length, the skyrmion spin texture extends into the third dimension and cannot be assumed as homogeneous. Using soft x-ray laminography, we reconstruct with about 20-nanometer spatial (voxel) size the full three-dimensional spin texture of a skyrmion in an 800-nanometer-diameter and 95-nanometer-thin disk patterned into a 30× [iridium/cobalt/platinum] multilayered film. A quantitative analysis finds that the evolution of the radial profile of the topological skyrmion number is nonuniform across the thickness of the disk. Estimates of the micromagnetic energy densities suggest that the changes in topological profile are related to nonuniform competing energetic interactions. Our results provide a foundation for nanoscale metrology for spintronics devices using topology as a design parameter.

36 MATERIALS SCIENCE↗

Transport Processes in a Li-ion Cell during an Internal Short-Circuit

Internal short-circuit in a lithium-ion cell causes an abrupt increase in cell temperature and triggers subsequent thermal runaway. In this work, we present a detailed electrochemical-thermal model to investigate the physical behavior during an internal short-circuit. Simulations at wide range of heat transfer coefficients and short-circuit resistances are conducted to illustrate electrochemical and thermal behavior under a wide range of conditions. The Joule heating at the shorted region promotes electrochemical reactions nearby, causing in-plane non-uniformity of electrolyte and active material transport. Furthermore, it is found that diffusion in solid active materials plays a significant role at very high shorting currents (~20 C), as electrochemical reactions rate are being controlled progressively more by availability of Li + at the interface, due to limitations in diffusion through the active material with increasing discharge rates. This diffusion limitation causes a drop in available energy, and subsequently a decrease in cell equilibrium potential and the heat generation rate at the location of the short. On the other hand, rapid depletion of lithium concentration in the electrolyte and accumulation on the electrode surface results in highly non-uniform transport properties resulting in higher heat generation rates. Hence, the heating regime shifts from "local heating" to "global heating". Based on the findings, important design parameters for battery safety are discussed.

25 ENERGY STORAGE↗

Can a transport model predict inverse signatures in Lithium metal batteries without modifying kinetics?

In this study, a one-dimensional transport model is developed and analyzed that predicts the inverse signatures obtained in lithium metal batteries. This simple approach’s ability to predict inverse signatures stems from the competing interplay between moving boundary rates and mass transfer limitations to yield inverse signatures without modifying the kinetics. The numerical scheme used for the present model simulations is presented in detail which has been further used to study the effect of design parameters on the prevalence and strength of inverse signatures. It was found that the proposed model and the analysis is more pertinent to thick symmetric cells, commonly used for in-depth fundamental studies.

model, transport, dendrite, lithium metal battery,↗

Tuning the Porous Structure in PMMA-Templated Mesoporous MoO 2 for Pseudocapacitive Li-Ion Electrodes

MoO 2 is an exciting candidate for next-generation energy storage. It can be used for fast-charging applications in nanoscale form, but its kinetic performance is often limited by insulating MoO 3 surface oxide layers. Here, we developed methods to produce polymer-templated porous MoO 2 powders where electrical conductivity was well-maintained throughout the structure, even in the presence of some surface oxidation. Porosity, pore size, and crystallite size were controlled by varying the amount and size of the colloidal templates and through calcination temperature. The electrochemical performance was correlated with nanoscale structure: samples with high porosity, medium pore sizes, and good crystallinity display optimal rate capabilities, with over 100 mAh g −1 delivered in 3 min and 93% capacity retention after 1000 cycles. Kinetic studies were performed on samples with the largest and smallest crystallite sizes to understand the charge storage mechanism. In the sample with the smallest crystallite size, 85% of the total stored charge was capacitive, compared to 60% for the largest crystallite size. Sloping voltage profiles in materials with smaller domain sizes further suggest suppression of intercalation-induced phase transitions. This work thus provides insights into the mechanisms of charge storage in nanoscale MoO 2 and design parameters for the production of fast charging materials.

25 ENERGY STORAGE↗

Predicted Impacts of Pt and Ionomer Distributions on Low-Pt-Loaded PEMFC Performance

Low-cost, high performance proton exchange membrane fuel cells (PEMFCs) have been difficult to develop due to limited understanding of coupled processes in the cathode catalyst layer (CCL). Low-Pt-loaded PEMFCs suffer losses beyond those predicted solely due to reduced catalyst area. Although consensus links these losses to thin ionomer films in the CCL, a precise mechanistic explanation remains elusive. In this publication, we present a physically based PEMFC model with novel structure-property relationships for thin-film Nafion, validated against PEMFC data with low Pt loading. Results suggest that flooding exacerbates kinetic limitations in low-loaded PEMFCs, shifting the Faradaic current distribution. As current density increases, protons travel further into the CCL, resulting in higher Ohmic overpotentials. We also present a parametric study of CCL design parameters. We find that graded Pt and ionomer loadings reduce Ohmic losses and flooding, but individually do not provide significant improvements. However, a dual-graded CCL (i.e., graded Pt and ionomer) is predicted to significantly improve the maximum power density and limiting current compared to uniformly loaded CCLs. This work highlights the importance of accurate transport parameters for thin-film Nafion and provides a pathway to low-cost PEMFCs via precise control of CCL microstructures.

08 HYDROGEN↗