Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Power Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Analysis of Electric Vehicle Charging Impact on the Electric Power Grid

In order to evaluate the impact of electric vehicles (EVs) on the distribution grid and assess their potential benefits to the future smart grid, it is crucial to study the EV charging patterns and the usage charging station. Though EVs are not yet widely adopted nationwide, a valuable methodology to conduct such studies is the statistical analysis of real-world charging data. This paper presents actual EV charging behavior of 64 EVs (5 brands, 8 models) from EV users and charging stations at Los Angeles Department of Water and Power for more than one year. Twenty-four-hour EV charging load curves have been generated and studied for various load periods: daily, monthly, seasonally and yearly. Finally, the effect and impact of EV load on the California distribution network are evaluated at different EV penetration rates.

33 ADVANCED PROPULSION SYSTEMS↗

A coherent description of thermal radiative devices and its application on the near-field negative electroluminescent cooling

Using the transmissivity between two thermal reservoirs and the generalized Planck distributions, we describe the devices that use radiative energy transfer between thermal reservoirs in a unified formalism. In this work, four types of devices are distinguished. For power generators that use the temperature difference between reservoirs, photovoltaic (PV) and thermoradiative (TR) devices respectively use the low temperature photovoltaic cell and high-temperature thermoradiative cell to generate electricity. For active cooling, the electroluminescent (EL) cooling devices apply a forward bias voltage on the object we want to cool, whereas the negative EL cooling devices apply a reverse bias voltage to the heat sink. The relationship among these four devices is explicated. The performance of the negative EL cooling is analyzed, both in the Shockley-Queisser (blackbody spectrum and radiative recombination) framework and the near-field enhancement. The “impedance match” condition derived for PV systems is applied to the negative EL devices. One advantageous feature of the negative EL cooling is that it does not apply the voltage to the target object which we want to cool, and the near-field enhancement can apply to various target materials that support the surface resonant modes.

42 ENGINEERING↗

Effects of a random spatial variation of the plasma density on the mode conversion in cold, unmagnetized, and stratified plasmas

We study the effects of a random spatial variation of the plasma density on the mode conversion of electromagnetic waves into electrostatic oscillations in cold, unmagnetized, and stratified plasmas. Using the invariant imbedding method, we calculate precisely the electromagnetic field distribution and the mode conversion coefficient, which is defined to be the fraction of the incident wave power converted into electrostatic oscillations, for the configuration where a numerically generated random density variation is added to the background linear density profile. We repeat similar calculations for a large number of random configurations and take an average of the results. We obtain a peculiar nonmonotonic dependence of the mode conversion coefficient on the strength of randomness. As the disorder increases from zero, the maximum value of the mode conversion coefficient decreases initially, then increases to a maximum, and finally decreases towards zero. The range of the incident angle in which mode conversion occurs increases monotonically as the disorder increases. We present numerical results suggesting that the decrease of mode conversion mainly results from the increased reflection due to the Anderson localization effect originating from disorder, whereas the increase of mode conversion of the intermediate disorder regime comes from the appearance of many resonance points and the enhanced tunneling between the resonance points and the cutoff point. We also find a very large local enhancement of the magnetic field intensity for particular random configurations. In order to obtain high mode conversion efficiency, it is desirable to restrict the randomness close to the resonance region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Frequency Control Method for Islanded Microgrids Using Energy Storage Systems

Islanded microgrids are vulnerable to frequency fluctuations due to the presence of low-inertia distributed energy resources (DERs). Moreover, implementation of both synchronous-based and inverter-based DERs with a significant difference in inertia leads to a power imbalance between generation and consumption during transients. This results in frequency variations which might have severe consequences such as blackouts. This paper develops a control scheme for battery energy storage systems (BESSs) to enhance the dynamic response of islanded microgrids by mitigating the frequency fluctuations. A piecewise linear-elliptic (PLE) droop characteristic is proposed and employed in BESS to achieve a faster power balance between generation and consumption during transients, resulting in enhanced frequency responses. Different case studies are carried out to validate the viability of the proposed approach in improving the dynamics of islanded microgrids.

Pilehvar, Mohsen S.↗

Electric Industry Structure and Regulatory Responses in a High Distributed Energy Resources Future

The emergence of distributed energy resources (DERs) that can generate, manage and store energy on the customer side of the electric meter is widely recognized as a transformative force in the power sector. This report focuses on two key aspects of that transformation: structural changes in the electric industry and related changes in business organization and regulation that are likely to result from them. Both industry structure and regulation are inextricably linked. History shows that the regulation of the power sector has responded primarily to innovation in technologies and business models that created significant structural changes in the sector’s cost and organizational structure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ARM-IRL: Adaptive Resilience Metric Quantification Using Inverse Reinforcement Learning

The resilience of safety-critical systems is gaining importance due to the rise in cyber and physical threats, especially within critical infrastructure. Traditional static resilience metrics may not capture dynamic system states, leading to inaccurate assessments and ineffective responses to cyber threats. This work aims to develop a data-driven, adaptive method for resilience metric learning. We propose a data-driven approach using inverse reinforcement learning (IRL) to learn a single, adaptive resilience metric. The method infers a reward function from expert control actions. Unlike previous approaches using static weights or fuzzy logic, this work applies adversarial inverse reinforcement learning (AIRL), training a generator and discriminator in parallel to learn the reward structure and derive an optimal policy. The proposed approach is evaluated on multiple scenarios: optimal communication network rerouting, power distribution network reconfiguration, and cyber–physical restoration of critical loads using the IEEE 123-bus system. The adaptive, learned resilience metric enables faster critical load restoration in comparison to conventional RL approaches.

97 MATHEMATICS AND COMPUTING↗

A Templated Approach for Multi-Physics Modeling of Hybrid Energy Systems in Modelica

A prototypical hybrid energy system (HES) couples a primary thermal power generator (i.e., nuclear power plant) with one or more additional subsystems beyond the traditional balance of plant electricity generation system. The definition and architecture of an HES can be adapted based on the needs and opportunities of a given local market. For example, locations in need of potable water may be best served by coupling a desalination plant to the HES. A location near an oil refinery may have a need for emission-free hydrogen production. The flexible, multidomain capabilities of Modelica are being used to investigate the dynamics (e.g., thermal hydraulics and electrical generation/consumption) of such a hybrid system. This paper examines the simulation infrastructure created to enable the coupling of multiphysics subsystem models for HES studies. A demonstration of a tightly coupled nuclear hybrid energy system implemented using the Modelica based infrastructure is presented for two representative cases. An appendix is also included providing a step-by-step procedure for using the template-based infrastructure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Earth Battery

It’s the bane of renewable energy. No matter how efficient photovoltaic cells become or how much power a wind turbine can capture, someone will counter with, “What happens when the sun goes down and wind doesn’t blow?” And the person who poses that question uses it as an argument in favor of traditional baseload power. While it’s true that the way the electrical grid has developed in North America and Europe doesn’t lend itself to the start-and-stop, opportunistic nature of wind and solar, there are ways to meet the challenge. Electricity can be stored in batteries or water pumped uphill into reservoirs when power generation exceeds demand, to be tapped when needed. Unfortunately, utility-scale battery storage is prohibitively expensive, and pumped hydro is possible only in particular geographic locations. What is needed is a large-scale, distributed, dispatchable energy storage system that can smooth out a renewable energy generation profile that changes by the minute as well as over the course of the day or the season. Colleagues from Lawrence Livermore National Laboratory, the Ohio State University (led by Jeffrey Bielicki), and the University of Minnesota (led by Jimmy Randolph), and I have developed a system that can do all that. What’s more, this system actually sequesters carbon dioxide—a gas implicated in global climate change—as part of its normal operation. Furthermore, we have modeled our system and found that, if it can be successfully demonstrated in the field, it could provide utility-scale diurnal and seasonal energy storage (many hundreds of MWe) and dispatchable power, while permanently sequestering CO 2 from industrial-scale fossil-energy power plants. Certainly, an energy storage system is only as clean or as green as the primary generation it’s working with. But it is going to be difficult to implement solar or wind power to a degree high enough to make a difference in global carbon dioxide emissions without utility-scale energy storage.

15 GEOTHERMAL ENERGY↗

Scalable Unit Commitment with Security Constrained AC Power Flow via ADMM and Hybrid Modeling Strategies

This research introduces a more efficient way to optimize power grid operations, breaking the problem into manageable steps and using advanced mathematical techniques to speed up calculations. By incorporating smart heuristics, improved preprocessing, and contingency analysis, the approach allows operators to make better decisions faster. These innovations enhance our understanding of how to optimize energy generation, making it possible to anticipate failures before they happen, reduce system costs, and improve overall grid performance. Ultimately, this research helps bridge the gap between theoretical models and real-world applications, paving the way for a smarter, more resilient power grid. This research directly benefits the public by making electricity more affordable, reliable, and sustainable. By improving how power grids schedule and distribute electricity, the project helps energy providers reduce operational costs, which can lead to lower electricity prices for consumers. Additionally, the ability to predict and prevent power system failures enhances grid reliability, reducing the likelihood of blackouts that can disrupt homes, businesses, and critical infrastructure such as hospitals. From an environmental perspective, optimizing power generation reduces energy waste and lowers carbon emissions, contributing to cleaner air and a more sustainable energy system. Furthermore, with extreme weather events becoming more frequent, these advancements make the power grid more resilient, ensuring communities are better prepared for emergencies and natural disasters. By strengthening the nation's energy infrastructure, this research plays a crucial role in improving economic stability, public safety, and environmental sustainability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Compressed Gas Energy Storage Integrated with Combined Heat and Power Plant

A new energy storage technology, Comrpessed Gas Energy Storage (CGES), seeks to achieve low-cost, long-duration eenrgy storage by combining mature commercially-available technology (compressors, high-pressure gas storage, expander generators) and utilizing existing infrastructure for transportation and distribution of industrial gases. CGES utilizes existing compressors to transform electricity into potential energy (pressure), existing pipelines or underground storage to store said potential energy, and adds new expander generators at pressure reduction points in the networkm to recover part of the energy used in compression and transform it into electricity. By adapting itself to widely available existing infrastructure, CGES recovers energy that is otherwise wasted in the gas value chain, reduces the cost of new facilities, and avoids many of the development huddles typically associated with other long-duration energy storage technologies (e.g., Compressed Air Energy Storage, CAES). This paper discusses the performance and economics associated with CGES as a standalone project and in combination with a thermal power plant, based on a concept for integration of the technology over an existing lateral pipeline transporting natural gas to an 85 MW combined heat and power plant that feeds power to a grid with increasing share of renewable power generation.

03 NATURAL GAS↗

Combined Effects of Electric Vehicle Charging and Rooftop Solar Integration on Voltage Imbalance in Residential Distribution Networks

Residential electric vehicle (EV) chargers, as single phase loads, contribute to unbalanced voltage drops across phases, while rooftop solar systems, as single phase generators, can exacerbate voltage imbalance by causing unbalanced voltage increases. This paper investigates combined effects of residential EV charging and rooftop solar generation on voltage imbalance in residential distribution grids. The study examines these simultaneous impacts using the IEEE 8500-node test system, enhanced with a secondary network to realistically model the EV chargers and rooftop solar integration. To account for the variability and uncertainty in the EV charging loads and solar generation, a Monte Carlo approach is employed to capture and quantify the simultaneous impact of the EV charging and rooftop solar integration. In this approach, multiple influencing factors are considered, including state-of-charge (SOC), maximum charging power levels, and geographic distribution of chargers. The results provide practical insights for utilities and stakeholders, offering expectations for planning and operating strategies that effectively manage the increasing adoption of EVs and solar power while maintaining grid reliability.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)↗

EVSE Cybersecurity and Resilience

Consequence-driven Cybersecurity Analysis for Extreme Fast Charging Electric Vehicle Infrastructure Electric vehicle (EV) development and associated charging infrastructure are expected to advance rapidly. Thirty percent of all global vehicle sales may be EVs and hybrid EVs by 2025, and they will rely on increasingly sophisticated strategies for grid integration. Next-generation EV charging infrastructure is expected to include interconnected renewable resources, such as photovoltaic (PV) arrays and battery storage systems, along with grid-edge devices. Although distributed energy resources (DERs) are useful in several ways, such as peak shaving at high demand times and backup supply for added resilience, the integration of vehicle charging and DERs could create more avenues for cyberattack. Physical and/or remote access to EV charging station components, including charge ports, power electronics, controllers, and local generation (e.g., PV and energy storage) could be paths to cause power fluctuations, leading to altered operations at the charging station, escalated privileges to administrative systems, exfiltration of financial information (including personally identifiable information), and reduced grid stability. One compromised EV supply equipment component can open the door to a variety of exploitable vulnerabilities. Cloud computing and mobile application control have the potential to expand the threat surface to non-repudiation and firmware integrity challenges. Vendor clouds have access to hundreds of chargers, and if compromised, can scale the attack surface exponentially. The high power and voltage levels of xFC infrastructure (e.g., 400 kW at 1000- V DC) increase the hazards and ability to impact the grid and vehicles more than lower-power charging systems. Legacy communications systems and protocols could also put EV infrastructure at risk of cyberattacks requiring a robust patch management process. Communications networks link EVs and chargers to several stakeholders - including charging station operators, grid operators, vendors/manufacturers, and aggregators - who have both physical and network access to share information for control, monitoring, and analytics. Information in these networks that is vulnerable to compromise includes the state of charge, charging duration, payment information, electricity price, and load control. Analyzing and prioritizing these interconnections risks could help address cybersecurity related to data leakage and manipulation.

charging↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗

Wholesale electricity market design with increasing levels of renewable generation: Revenue sufficiency and long-term reliability

This paper discusses challenges that relate to assessing and properly incentivizing the resources necessary to ensure a reliable electricity system with growing penetrations of variable generation (VG). The output of VG (primarily wind and solar generation) varies over time and cannot be predicted precisely. Therefore, the energy from VG is not always guaranteed to be available at times when it is most needed. This means that its contribution towards resource adequacy can be significantly less than the contribution from traditional resources. Variable renewable resources also have near-zero variable costs, and with production-based subsidies they may even have negative offer costs. Because variable costs drive the spot price of energy, this can lead to reduced prices, sales, and therefore revenue for all resources within the energy market. The characteristics of VG can also result in increased price volatility as well as the need for more flexibility in the resource fleet in order to maintain system reliability. Furthermore, we explore both traditional and evolving electricity market designs in the United States that aim to ensure resource adequacy and sufficient revenues to recover costs when those resources are needed for long-term reliability. We also investigate how reliability needs may be evolving and discuss how VG may affect future electricity market designs.

17 WIND ENERGY↗

Secondary Frequency Regulation from Variable Generation through Uncertainty Decomposition: An Economic and Reliability Perspective

The rapid integration of variable generation (VG), such as photovoltaics (PV), necessitates an increase in the secondary frequency regulation (SFR) to handle the system intra-dispatch interval imbalance because of VG's variation. Although PV has the control capability to provide SFR, the main challenge is in guaranteeing the delivery of PV's energy and SFRs capacities in the automatic generation control (AGC) within each dispatch interval considering its uncertainty. This paper proposes a deliverable VG SFR provision model with endogenous VG's power uncertainty decomposition. First, the uncertainty of VG is decomposed using distributionally robust chance constraints through which the deliverable SFR provision is guaranteed. Next, the intra-interval frequency response of PV's SFR is validated with a user defined AGC model including the PV power plant. Finally, the economic benefits and the reliability improvements such as the frequency deviation reduction with PV providing SFRcan be integrated and evaluated. The proposed model is tested in a modified 18-bus system and in the Western Electricity Coordinating Council test system. Results demonstrate that with the deliverable SFR from PV, the system cost and the frequency reliability can be improved simultaneously. PV's SFR performance can be guaranteed with the proposed model.

14 SOLAR ENERGY↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration: Preprint

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗

VersiCharge-SG - Smart Grid Capable Electric Vehicle Supply Equipment (EVSE) for Residential Applications

In his 2011 State of the Union address, President Obama called for one million electric vehicles on the road by 2015 [1]. With large-scale Electric Vehicle (EV) or Plug-in Electric Vehicle (PEV or EV for short) or Plug-in Hybrid Electric Vehicle (PHEV) penetration into the US market, there will be drastic reduction in fossil fuel consumption, thus significantly reducing our dependency on foreign oil [2-6]. There will also be significant reduction on Green House Gas (GHG) emissions and smog in the major US cities [3, 7, 8]. Similar studies have also been done other industrial counties [9]. For the fuel cost, with the home electricity rate around $0.13 per kWh, it would cost about $0.05 per mile for DC operation and $0.03 cents per mile for AC operation. But, assuming 25 miles per gallon for a typical vehicle and $4 per gallon, fossil fuel will cost $0.16 per mile [10]. The overall lifecycle cost of PEVs will be several folds lower than the existing fossil fueled vehicles. Despite the above advantages of the EVs, the current cost of EVSE is not affordable for the average consumer. Presently, the cost of installing state-of-the-art residential EVSE ranges from $1500 to $2500 [11]. Low priced EVSE technology, which is easy to install, and affordable to operate and maintain by an average consumer, is essential for the large-scale market penetration of EVs. In addition, the long-term success of this technology is contingent on the PEVs having minimal excessive load and shift impact on the grid, especially at peak times. In a report [2] published by the Pacific Northwest National Laboratory (PNNL), the exiting electric power generation infrastructure, if used at its full capacity 24 hours a day, would support up to 84% of the nation’s cars, pickup trucks and SUVs for an average daily drive of 33 miles. This mileage estimate is certainly much below what an average driver would drive his/her vehicle per day. Another report [3] by the National Renewable Energy Laboratory (NREL) shows that an increased PEV penetration would significantly increase pressure on the peak generation, if no controlled charging strategy was put in place. Investigations from Oak Ridge National Laboratory (ORNL) show that in many regions, additional power generation facilities must be put in place and operate in evening times to recharge the EVs [12]. By all accounts, large PEV penetration will bring to the power grid enormous challenges due to the excessive and stochastic demand, and can entirely change the peak time distribution and behavior, perhaps, into a bi-modal distribution capable of exhausting primary, secondary and even reserves (spinning or non-spinning). To minimize the infrastructure upgrade costs and risks to the grid, and to ensure that power quality and reliability remain within the set standards, the demand for EV plug-ins must then be controlled and coordinated locally and at regional levels. Novel control techniques must be devised to allow for close collaboration between neighboring plug-in requestors, between neighboring communities, and between these and more central power authorities. The concept of electric drive vehicle is not new. The development of electric vehicle has been around since 19th century [13]. But due to a number of reasons and practical limitations at the time, including lower cost of gasoline compared to electricity, excessive refueling times, and abundance of gasoline, the automobile industry embraced gasoline-powered vehicles worldwide [13]. With the global warming, ever reducing reservoirs of fossil oil around the world and increasing political pressure to reduce the national dependency on foreign oil, the last decade of the 20th century witnessed major technological breakthroughs in Alternative Fueled Vehicle (AFV) technologies, including electric vehicles. With GHG emissions and carbon footprint in the minds of many more consumers and politicians, the first decade of the 21stCentury witnessed more breakthroughs with some real life experimentation and sporadic deployment of these technologies [14]. By many accounts, the second decade of the 21st Century is expected to be the time when mass volume production and popular usage of these AFV technologies, especially EV, will materialize. The current DOE request for proposals recognizes the need for major technological changes to ensure that the above national goal is realizable. Two major challenges have been identified: (1) major reduction in the cost of ownership of EVSEs, and (2) managing additional EV loads in the power grid while maintaining power quality, reliability, and affordability. We note that the two challenges are closely linked – A holistic approach to true lifecycle cost of EVSE ownership will certainly include any taxes and surcharges that can be put in place for major potential investments in the grid, and higher electricity charges in case of more frequent and longer peak periods. From a societal perspective, this cost could also include the lost GDP (computed on a local basis) and revenue for businesses at local and regional levels when the grid is no longer capable of meeting the demand and unexpected outages occur. A typical end-point electrical distribution system delivers power to a residential EVSE from the neighborhood distribution pole, as shown in Fig.1. This pole has a transformer (neighboring step-down transformer) that steps down the utility medium voltage to dual 120VAC single phase (also called 240VAC split phase). This voltage is fed through a meter into the residential load control center. The load control center consists of branch circuit breakers and distributes the power supply within various areas of the residential unit. One of the branch circuits from the load control center feeds EV charging station for the unit. An electric vehicle charger is plugged into the socket of the EV charging station and other end of this charger is connected to the vehicle during charging. Figure 1 illustrates a typical configuration of the power grid. The left side of the figure shows the power grid from the power generation to the neighboring step-down transformer, while the right side of the figure shows multiple EVs with the respective charging stations. The typical step-down transformer has an upper limit representing the maximum load that can be requested from these neighboring houses altogether (typically 24 kW). In case the total load increases beyond the supported limit, the protection system (e.g. a circuit breaker) attached to the step-down transformer gets activated automatically.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗