Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Partitioning of Ionization and Displacement Kerma in Material Response Functions

Calculations of total dose (relatable to heating) and ionizing dose (relatable to electron - hole pair formation) typically rely upon material kerma response functions and an assumption of charged particle equilibrium. Traditionally, kerma functions designed for use with the Sandia ASC NuGET code were created via the HEATR module of the NJOY code system, in which a simplifying monoatomic assumption in made. The purpose of this study is to relax that approximation through the use of binary collision simulation techniques, which can take into account the co - existence of multiple elements in a material. Specifically, the total, ionization, and displacement components of kerma are evaluated in silicon, gallium arsenide, gallium nitride, and indium phosphide using the TRIM and MARLOWE codes, and are compared against the equivalent NJOY - based functions. Based on the results, a binary collision - based methodology is proposed for extracting the partial kerma components of high - importance materials.

36 MATERIALS SCIENCE↗

Preliminary estimates of galactic cosmic ray shielding requirements for manned interplanetary missions

Estimates of radiation risk to the blood forming organs from galactic cosmic rays are presented for manned interplanetary missions. The calculations use the Naval Research Laboratory cosmic ray spectrum model as input into the Langley Research Center galactic cosmic ray transport code. This transport code, which transports both heavy ions and nucleons, can be used with any number of layers of target material, consisting of up to five different constituents per layer. Calculated galactic cosmic ray doses and dose equivalents behind various thicknesses of aluminum and water shielding are presented for solar maximum and solar minimum periods. Estimates of risk to the blood forming organs are made using 5 cm depth dose/dose equivalent values for water. These results indicate that at least 5 g/sq cm (5 cm) of water of 6.5 g/sq cm (2.4 cm) of aluminum shield is required to reduce annual exposure below the current recommended limit of 50 rem. Because of the large uncertainties in fragmentation parameters, and the input cosmic ray spectrum, these exposure estimates may be uncertain by as much as 70 percent. Therefore, more detailed analyses with improved inputs could indicate the need for additional shielding.

Townsend, Lawrence W.↗

Human exposure to galactic cosmic rays in space

The Langley Research Center GCR (galactic cosmic rays) code (HZETRN) and the computerized Anatomical Man (CAM) model are used to estimate astronaut exposures, from GCR particles, for missions beyond earth's magnetosphere. Conventional risk assessments in terms of total absorbed dose and dose equivalent are made for skin, ocular lens, and bone marrow. For each organ, evaluations are made of relative contributions from incident protons, iron nuclei, and their secondary reaction products.

Townsend, L. W.↗

A high speed CCSDS encoder for space applications

This paper reports a VLSI implementation of the CCSDS standard Reed Solomon encoder circuit for the Space Station. The 1.0 micron double metal CMOS chip is 5.9 mm by 3.6 mm, contains 48,000 transistors, operates at a sustained data rate of 320 Mbits/s, and executes 2,560 Mops. The chip features a pin selectable interleave depth of 1 to 8. Block lengths of up to 255 bytes, as well as shortened codes, are supported. The control circuitry uses register cells which are immune to Single Event Upset. In addition, the CMOS process used is reported to be tolerant of over 1 Mrad total dose radiation.

Whitaker, S.↗

Radiation Environment Inside Spacecraft

Dr. Patrick O'Neill, NASA Johnson Space Center, will present a detailed description of the radiation environment inside spacecraft. The free space (outside) solar and galactic cosmic ray and trapped Van Allen belt proton spectra are significantly modified as these ions propagate through various thicknesses of spacecraft structure and shielding material. In addition to energy loss, secondary ions are created as the ions interact with the structure materials. Nuclear interaction codes (FLUKA, GEANT4, HZTRAN, MCNPX, CEM03, and PHITS) transport free space spectra through different thicknesses of various materials. These "inside" energy spectra are then converted to Linear Energy Transfer (LET) spectra and dose rate - that's what's needed by electronics systems designers. Model predictions are compared to radiation measurements made by instruments such as the Intra-Vehicular Charged Particle Directional Spectrometer (IV-CPDS) used inside the Space Station, Orion, and Space Shuttle.

O'Neill, Patrick↗

Evaluation of the concrete shield compositions from the 2010 criticality accident alarm system benchmark experiments at the CEA Valduc SILENE facility

In October 2010, a series of benchmark experiments were conducted at the French Commissariat a l'Energie Atomique et aux Energies Alternatives (CEA) Valduc SILENE facility. These experiments were a joint effort between the United States Department of Energy Nuclear Criticality Safety Program and the CEA. The purpose of these experiments was to create three benchmarks for the verification and validation of radiation transport codes and evaluated nuclear data used in the analysis of criticality accident alarm systems. This series of experiments consisted of three single-pulsed experiments with the SILENE reactor. For the first experiment, the reactor was bare (unshielded), whereas in the second and third experiments, it was shielded by lead and polyethylene, respectively. The polyethylene shield of the third experiment had a cadmium liner on its internal and external surfaces, which vertically was located near the fuel region of SILENE. During each experiment, several neutron activation foils and thermoluminescent dosimeters (TLDs) were placed around the reactor. Nearly half of the foils and TLDs had additional high-density magnetite concrete, high-density barite concrete, standard concrete, and/or BoroBond shields. CEA Saclay provided all the concrete, and the US Y-12 National Security Complex provided the BoroBond. Measurement data from the experiments were published at the 2011 International Conference on Nuclear Criticality (ICNC 2011) and the 2013 Nuclear Criticality Safety Division (NCSD 2013) topical meeting. Preliminary computational results for the first experiment were presented in the ICNC 2011 paper, which showed poor agreement between the computational results and the measured values of the foils shielded by concrete. Recently the hydrogen content, boron content, and density of these concrete shields were further investigated within the constraints of the previously available data. New computational results for the first experiment are now available that show much better agreement with the measured values.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Geologic Disposal Safety Assessment (GDSA) Biosphere Model Development

The Spent Fuel and Waste Science and Technology Campaign of the U.S. Department of Energy Office of Nuclear Energy, Office of Spent Fuel and Waste Disposition is conducting research and development on geologic disposal of spent nuclear fuel and high-level nuclear waste. This work includes the Geologic Disposal Safety Assessment (GDSA) program which is charged with development of generic deep geologic repository concepts and system performance assessment models. One part of the GDSA framework is the development of a biosphere model capable of assessing doses to potential receptors exposed to radionuclides released from geologic disposal sites. As part of the GDSA framework, a biosphere model compatible with the PFLOTRAN massively parallel subsurface flow and reactive transport code is under development. The PFLOTRAN model provides the radionuclide source term for the biosphere model. The GDSA Biosphere model then assesses the potential movement of radionuclides through the surface biosphere and the subsequent exposure to a human receptor living in the biosphere. The biosphere model includes pathways originating from the groundwater as well as pathways originating from surface water bodies that have a water exchange with a contaminated groundwater body. The pathways for human exposure include consumption of drinking water, irrigated crops, meat animals, aquatic vegetation, and animals, etc.; external exposure from irrigated ground surfaces, surface water bodies, recreational activities, etc.; and inadvertent exposures such as ingestion of contaminated soils or shower water, etc. The GDSA Biosphere model was designed to be flexible and generic in order to accommodate a variety of different sites and climate states. This presentation will present the on the purpose, design, and development progress of the GDSA Biosphere Model.

GDSA, biosphere, repository↗

SU-F-18C-10: Clinical Implementation of Radiochromic Film Based CTDI Measurements

Purpose: To evaluate accuracy and reproducibility of a radiochromic film-based protocol to measure computer tomography dose index (CTDI) as a part of annual QA on CT scanners and kV CBCT systems attached to linear accelerators. Methods: Energy dependence of Gafchromic XR-QA2(R) film model was tested over imaging beam qualities (50 – 140 kVp). Film pieces were irradiated in air to known values of air kerma in air (up to 10 cGy). Change in film reflectance was determined with an in-house written code using images produced by a flatbed document scanner. Calibration curves for each beam quality were created, and film responses for same air-kerma values were compared.Sets of film strips were placed into holes of a CTDI phantom and irradiated for several clinical scanning protocols on CT-simulators and CBCT systems. Film reflectance change was converted into dose to water and used to calculate CTDIvol values. Measured CTDIvol values were compared to tabulated CTDIvol values. Results: Average variations of ±5.2% in the mean film reflectance change were observed in the energy range of 80 to 140 keV, and 11.1% between 50 and 140 keV. The averaged measured CTDI values presented a mean variation for the same machine and protocol of 2.6%. However, measured CTDI values were in average 10% lower than tabulated CTDI values for CT-simulators, and 44% higher for CBCT systems. Conclusion: We found that in relatively broad range of beam qualities used in diagnostic radiology variation of film response is within ±5% resulting in ±15% systematic error in dose estimates if a single calibration curve is used. Relatively large discrepancy between measured and tabulated CTDI values for different protocols and imaging systems used within radiotherapy department strongly support the trend towards replacing CTDI value with equilibrium dose measurement in the center of cylindrical phantom as suggested by TG-111. This work was supported by the Natural Sciences and Engineering Research Council of Canada, Contract No. 386009; Partial support by CREATE, Medical Physics Research Training Network grant of the Natural Science and Engineering Research Council, Contract No. 432290.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of Attila Transport Code with MCNP in the Analysis of Small Modular Reactor Shielding

Of great importance in the design of a nuclear power plant is the evaluation of shielding from the ionizing radiation produced in the core of the nuclear reactor. This requires simulation software to predict the dose rates in the areas of interest. These problems are referred to as deep penetration problems, as they involve the reduction of a radiation field by two or three orders of magnitude or more. This makes accurate analyses difficult for Monte Carlo based solutions that rely on enough particles being sampled in an area of interest. Comparing the simulation of the same modeled system with more than one computer application, especially one that uses a different algorithmic approach, is a way to gain confidence in the results. In this research, two models were created, one in Monte Carlo N Particle (MCNP) which uses a stochastic algorithmic approach, and the other in Attila, which uses a deterministic algorithmic approach to test the validity of the model and to estimate the dose rates in the area of interest. Successful comparison of the two models is a way we can validate the model used for that estimation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fully iterative scatter corrected digital breast tomosynthesis using GPU-based fast Monte Carlo simulation and composition ratio update

Purpose: In digital breast tomosynthesis (DBT), scatter correction is highly desirable, as it improves image quality at low doses. Because the DBT detector panel is typically stationary during the source rotation, antiscatter grids are not generally compatible with DBT; thus, a software-based scatter correction is required. This work proposes a fully iterative scatter correction method that uses a novel fast Monte Carlo simulation (MCS) with a tissue-composition ratio estimation technique for DBT imaging. Methods: To apply MCS to scatter estimation, the material composition in each voxel should be known. To overcome the lack of prior accurate knowledge of tissue composition for DBT, a tissue-composition ratio is estimated based on the observation that the breast tissues are principally composed of adipose and glandular tissues. Using this approximation, the composition ratio can be estimated from the reconstructed attenuation coefficients, and the scatter distribution can then be estimated by MCS using the composition ratio. The scatter estimation and image reconstruction procedures can be performed iteratively until an acceptable accuracy is achieved. For practical use, (i) the authors have implemented a fast MCS using a graphics processing unit (GPU), (ii) the MCS is simplified to transport only x-rays in the energy range of 10–50 keV, modeling Rayleigh and Compton scattering and the photoelectric effect using the tissue-composition ratio of adipose and glandular tissues, and (iii) downsampling is used because the scatter distribution varies rather smoothly. Results: The authors have demonstrated that the proposed method can accurately estimate the scatter distribution, and that the contrast-to-noise ratio of the final reconstructed image is significantly improved. The authors validated the performance of the MCS by changing the tissue thickness, composition ratio, and x-ray energy. The authors confirmed that the tissue-composition ratio estimation was quite accurate under a variety of conditions. Our GPU-based fast MCS implementation took approximately 3 s to generate each angular projection for a 6 cm thick breast, which is believed to make this process acceptable for clinical applications. In addition, the clinical preferences of three radiologists were evaluated; the preference for the proposed method compared to the preference for the convolution-based method was statistically meaningful (p < 0.05, McNemar test). Conclusions: The proposed fully iterative scatter correction method and the GPU-based fast MCS using tissue-composition ratio estimation successfully improved the image quality within a reasonable computational time, which may potentially increase the clinical utility of DBT.

60 APPLIED LIFE SCIENCES↗

SU-F-T-144: Analytical Closed Form Approximation for Carbon Ion Bragg Curves in Water

Purpose: Semi-empirical modeling is a powerful computational method in radiation dosimetry. A set of approximations exist for proton ion depth dose distribution (DDD) in water. However, the modeling is more complicated for carbon ions due to fragmentation. This study addresses this by providing and evaluating a new methodology for DDD modeling of carbon ions in water. Methods: The FLUKA, Monte Carlo (MC) general-purpose transport code was used for simulation of carbon DDDs for energies of 100–400 MeV in water as reference data model benchmarking. Based on Thomas Bortfeld’s closed form equation approximating proton Bragg Curves as a basis, we derived the critical constants for a beam of Carbon ions by applying models of radiation transport by Lee et. al. and Geiger to our simulated Carbon curves. We hypothesized that including a new exponential (κ) residual distance parameter to Bortfeld’s fluence reduction relation would improve DDD modeling for carbon ions. We are introducing an additional term to be added to Bortfeld’s equation to describe fragmentation tail. This term accounts for the pre-peak dose from nuclear fragments (NF). In the post peak region, the NF transport will be treated as new beams utilizing the Glauber model for interaction cross sections and the Abrasion- Ablation fragmentation model. Results: The carbon beam specific constants in the developed model were determined to be : p= 1.75, β=0.008 cm-1, γ=0.6, α=0.0007 cm MeV, σmono=0.08, and the new exponential parameter κ=0.55. This produced a close match for the plateau part of the curve (max deviation 6.37%). Conclusion: The derived semi-empirical model provides an accurate approximation of the MC simulated clinical carbon DDDs. This is the first direct semi-empirical simulation for the dosimetry of therapeutic carbon ions. The accurate modeling of the NF tail in the carbon DDD will provide key insight into distal edge dose deposition formation.

07 ISOTOPE AND RADIATION SOURCES↗

Doses and fluxes in the proton-irradiated Big Target: A MARS15 analysis

This work is aimed at determination of secondary particle fluxes, prompt and residual doses as well as energy deposition in and around the Big Target, a 20-tonnes cylindrical target made of natural uranium with the lead core and a stainless-steel yoke, which is being considered to be irradiated by a 0.16-μA 600-MeV proton beam of the JINR Phasotron accelerator. The simulations were performed with the use of the MARS15 particle transport code employing the LAQGSM and CEM generators and based on the ENDFB-VIII neutron cross section library. The calculations for 12-hour, 100-hour, and 3-day irradiations with the aforementioned conditions indicate that temperature rise due to the beam does not require target cooling, the target can be safely handled soon after the end of irradiation, and its decommissioning is possible three years past the irradiation. Doses

43 PARTICLE ACCELERATORS↗

Updated Noise Dose Range of NASA’s X-59 Aircraft Estimated from Propagation Simulations

A follow-on study to Doebler and Loubeau, “The noise dose range of the X-59 estimated from propagation simulations,” JASA 150(4), A208 (2021); doi:10.1121/10.0008134 is described. In the previous work, propagation simulations of NASA’s X-59 sonic thump were conducted using two near-field pressure solutions from NASA’s Cart3D computational fluid dynamics (CFD) code. The near-fields were propagated through realistic atmospheric profiles from the Climate Forecast System Version 2 database across the USA, and Perceived Level statistics of the thumps were presented. The current work repeats the previous analyses, instead using near-field CFD solutions from NASA’s Fully Unstructured Navier-Stokes (FUN3D) code for the same aircraft conditions (Mach 1.4 at 53,200 feet and Mach 1.3 at 43,000 feet), which achieve the minimum and maximum cruise loudness. NASA and contractors in the X-59 development and community noise testing project mutually agreed upon using FUN3D for generating near-field pressures. Sonic thump loudness statistics using the FUN3D near-fields are similar to those of Cart3D. The min loudness condition is about 1 dB (PL) greater when using the FUN3D solution, and the max loudness condition results are nearly identical. Understanding the X-59’s dose range for various flight and atmospheric conditions is important for planning X-59 community noise surveys.

X-59↗

State Policies on Access to Vaccination Services for Low-Income Adults

Importance State vaccination benefits coverage and access for adult Medicaid beneficiaries vary substantially. Multiple studies have documented lower vaccination uptake in publicly insured adults compared with privately insured adults. Objective To evaluate adult Medicaid beneficiaries’ access to adult immunization services through review of vaccination benefits coverage in Medicaid programs across the 50 states and the District of Columbia. Design, Setting, and Participants A public domain document review with supplemental semistructured telephone survey was conducted between June 1, 2018, and June 14, 2019, to evaluate vaccination services benefits in fee-for-service and managed care organization arrangements for adult Medicaid beneficiaries in the 50 states and the District of Columbia (total, 51 Medicaid programs). Exposures Document review of benefits coverage for adult immunization services and supplemental survey with validation of document review findings. Main Outcomes and Measures Benefits coverage for adult Medicaid beneficiaries and reimbursement amounts for vaccine purchase and administration. Results Public domain document review was completed for all 51 jurisdictions. Among these, 44 Medicaid programs (86%) validated document review findings and completed the survey. Only 22 Medicaid programs (43%) covered all 13 Advisory Committee on Immunization Practices–recommended adult immunizations under both fee-for-service and managed care organization arrangements. Most fee-for-service arrangements (37 of 49) reimbursed health care professionals using any of the 4 approved vaccine administration codes; however, 8 of 49 programs did not separately reimburse for vaccine administration to adult Medicaid beneficiaries. Depending on administration route, median reimbursement for adult vaccine administration ranged from $\$9.81$ to $\$13.98$ per dose. Median per-dose reimbursement for adult vaccine purchase was highest for 9-valent human papillomavirus vaccine ($\$204.87$) and lowest for Haemophilus influenzae type b vaccine ($\$18.09$). Median reimbursement was below the private sector price for 7 of the 13 included vaccines. Conclusions and Relevance Even in programs with complete vaccination benefits coverage, reimbursement amounts to health care professionals for vaccine purchase and administration may not fully cover vaccination provision costs. Reimbursement amounts below costs may reduce incentives for health care professionals to vaccinate low-income adults and thereby limit Medicaid adult beneficiary access to vaccination.

60 APPLIED LIFE SCIENCES↗

National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions, Calendar Year 2011

The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada National Security Site (NNSS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NNSS. After nuclear testing ended in 1992, NNSS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) limits the release of radioactivity from a U.S. Department of Energy (DOE) facility to that which would cause 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as the damaged Fukushima nuclear power plant in Japan. Radionuclides from the Fukushima nuclear power plant were detected at the NNSS in March 2011 and are discussed further in Section III. The NNSS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the EPA for use on the NNSS in 2001 and has been the sole method used since 2005. Six locations on the NNSS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no member of the public actually resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration is less than the NESHAP Concentration Levels (CLs) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2. For multiple radionuclides, compliance is demonstrated when the sum of the fractions (determined by dividing each radionuclide's concentration by its CL and then adding the fractions together) is less than 1.0. In 2011, the potential dose from radiological emissions to air, resulting from both current and past NNSS activities, at onsite compliance monitoring stations was well below the 10 mrem/yr dose limit. Air sampling data collected at all air monitoring stations had average concentrations of radioactivity that were a fraction of the CL values. Concentrations ranged from less than 1% to a maximum of 12.2% of the allowed NESHAP limit. Because the nearest member of the public resides about 20 kilometers from potential release points on the NNSS, dose to the public would be only a small fraction of the value measured on the NNSS. The potential dose to the public from NLVF emissions was also very low at 0.000024 mrem/yr, more than 400,000 times lower than the 10 mrem/yr limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiological NESHAP Annual Report CY 2015 Sandia National Laboratories New Mexico

This report provides a summary of the radionuclide releases from the United States (U.S.) Department of Energy (DOE) National Nuclear Security Administration facilities at Sandia National Laboratories, New Mexico (SNL/NM) during Calendar Year (CY) 2015, including the data, calculations, and supporting documentation for demonstrating compliance with 40 Code of Federal Regulation (CFR) 61.

54 ENVIRONMENTAL SCIENCES↗

Risk analyses for the solar particle events of August through December 1989

The solar particle events of August through December 1989, among the largest ever recorded, are analyzed to assess the potential hazards to humans on interplanetary missions from events of these types. Using the coupled neutron-proton space radiation transport computer code BRYNTRN, risk estimates for the effects of exposures to the skin, ocular lens, and bone marrow are made for nominal thicknesses of the spacecraft aluminum shielding. Risk assessment in terms of absorbed dose is made for each event. Also presented are estimates of organ absorbed dose and dose equivalent for pairs of events which occurred within 30-day periods, and for the cumulative August through December 1989 period.

Townsend, Lawrence W.↗

Chromosome aberrations in the blood lymphocytes of astronauts after space flight

Cytogenetic analysis of the lymphocytes of astronauts provides a direct measurement of space radiation damage in vivo, which takes into account individual radiosensitivity and considers the influence of microgravity and other stress conditions. Chromosome exchanges were measured in the blood lymphocytes of eight crew members after their respective space missions, using fluorescence in situ hybridization (FISH) with chromosome painting probes. Significant increases in aberrations were observed after the long-duration missions. The in vivo dose was derived from the frequencies of translocations and total exchanges using calibration curves determined before flight, and the RBE was estimated by comparison with individually measured physical absorbed doses. The values for average RBE were compared to the average quality factor (Q) from direct measurements of the lineal energy spectra using a tissue-equivalent proportional counter (TEPC) and radiation transport codes. The ratio of aberrations identified as complex was slightly higher after flight, which is thought to be an indication of exposure to high-LET radiation. To determine whether the frequency of complex aberrations measured in metaphase spreads after exposure to high-LET radiation was influenced by a cell cycle delay, chromosome damage was analyzed in prematurely condensed chromosome samples collected from two crew members before and after a short-duration mission. The frequency of complex exchanges after flight was higher in prematurely condensed chromosomes than in metaphase cells for one crew member.

NASA Center JSC↗