Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPECTATION VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Diffusion Dynamics in a Tevatron Store

A separator failure during a store in 2002 led to a drop in luminosity, to increased emittance growth and to a drop in beam lifetimes. We show that a simple diffusion model can be used to explain the changes in beam lifetimes. Emittance growth of beams when they are in collision occurs due to many sources: beam-beam interactions, magnetic nonlinearities, intra-beam scattering, scattering off the residual gas and possibly others. The dynamics of the emittance growth is complicated and it depends strongly on the tunes. It is not always clear that the dynamics can be described by a diffusion process at all particle amplitudes in each beam. However in one store early in Run II, there was a sudden drop in a separator voltage in the Tevatron and the subsequent enhanced emittance growth and intensity lifetime drop could be described by a simple diffusion model. In this report we analyze the luminosity drop, compare the measured value with the expected drop and analyze the change in beam lifetimes. We show how a simple model of diffusive emittance growth and a change in physical aperture provides a quantitative explanation for the change in lifetimes.

43 PARTICLE ACCELERATORS↗

Exploring the growth index γ L : Insights from different CMB dataset combinations and approaches

In this study we investigate the growth index γ L , which characterizes the growth of linear matter perturbations, while analysing different cosmological datasets. We compare the approaches implemented by two different patches of the cosmological solver : and __. In our analysis we uncover a deviation of the growth index from its expected Λ CDM value of 0.55 when utilizing the Planck dataset, both in the case and in the __ case, but in opposite directions. This deviation is accompanied by a change in the direction of correlations with derived cosmological parameters. However, the incorporation of cosmic microwave background lensing data helps reconcile γ L with its Λ -cold dark matter value in both cases. Conversely, the alternative ground-based telescopes Atacama Cosmology Telescope and South Pole Telescope consistently yield growth index values in agreement with γ L = 0.55 . We conclude that the presence of the A lens problem in the Planck dataset contributes to the observed deviations, underscoring the importance of additional datasets in resolving these discrepancies. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Excited upsilon radiative decays

Bottomonium S-wave states were studied using lattice NRQCD. Masses of ground and excited states were calculated using multiexponential fitting to a set of correlation functions constructed using both local and wavefunction-smeared operators. Three-point functions for M1 transitions between vector and pseudoscalar states were computed. Robust signals for transitions involving the first two excited states were obtained. The qualitative features of the transition matrix elements are in agreement with expectations. The calculated values of matrix elements for {Upsilon}(2S) and {Upsilon}(3S) decay are considerably larger than values inferred from measured decay widths.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of the Magnetic-Field-Tuned Conductivity of Disordered Two-Dimensional Mo 43 ⁢Ge 57 and InO 𝑥 Superconducting Films: Evidence for a Universal Minimum Superfluid Response

Our measurements of the low frequency ac conductivity in strongly disordered two-dimensional films near the magnetic-field-tuned superconductor-to-insulator transition show a sudden drop in the phase stiffness of superconducting order with either increased temperature or magnetic field. Surprisingly, for two different material systems, the abrupt drop in the superfluid density in a magnetic field has the same universal value as that expected for a Berezinskii-Kosterlitz-Thouless transition in a zero magnetic field. As a result, the characteristic temperature at which phase stiffness is suddenly lost can be tuned to zero at a critical magnetic field, following a power-law behavior with a critical exponent consistent with that obtained in previous dc transport studies on the dissipative side of the transition.

Misra, S.↗

Production of Aluminum Stabilized Superconducting Cable for the Mu2e Transport Solenoid

Here, the Fermilab Mu2e experiment, currently under construction at Fermilab, has the goal of measuring the rare process of direct muon to electron conversion in the field of a nucleus. The experiment features three large superconducting solenoids: the production solenoid (PS), the transport solenoid (TS), and the detector solenoid (DS). The TS is an “S-shaped” solenoid that sits in between the PS and the DS producing a magnetic field ranging between 2.5 and 2.0 T. This paper describes the various steps that led to the successful procurement of over 740 km of superconducting wire and 44 km of Al-stabilized Rutherford cable needed to build the 52 coils that constitute the Mu2e TS cold mass. The main cable properties and results of electrical and mechanical test campaigns are summarized and discussed. Critical current measurements of the Al-stabilized cables are presented and compared to expected critical current values as measured on extracted strands from the final cables after chemical etching of the aluminum stabilizer. A robust and reliable approach to cable welding is presented, and the effect of cable bending on the transport current is also investigated and presented.

43 PARTICLE ACCELERATORS↗

High temperature deuterium enrichment using TiC coated vanadium membranes

Here, the current technology for hydrogen isotope separation requires enormous capital investment and energy consumption. Palladium-based membranes exhibit hydrogen isotope selectivity and provide a continuous method of isotope enrichment but have high material costs. Here, the authors investigate the potential of titanium carbide thin films coated on vanadium as a low-cost alternative, which enabled operation at high temperatures. Protium and deuterium exhibited nominally identical solubility in TiC coated vanadium over a range of 500–700°C. Permeation tests from 600 to 700°C revealed that protium permeated faster than deuterium, with the separation factor decreasing from 1.34 to 1.15 with increasing temperature. XPS depth-profiling showed a distinct interface between the TiC layer and the V foil in as-fabricated membranes. However, post-test analysis revealed significant V diffusion through TiC and segregation to the surface. Surface limitations resulting from this degradation accounted for changes in flux and may explain why the separation factor was lower than the value of 1.42 expected from high temperature interstitial diffusion of protium/deuterium in vanadium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MO-F-16A-02: Simulation of a Medical Linear Accelerator for Teaching Purposes

Purpose: Detailed functioning of linear accelerator physics is well known. Less well developed is the basic understanding of how the adjustment of the linear accelerator's electrical components affects the resulting radiation beam. Other than the text by Karzmark, there is very little literature devoted to the practical understanding of linear accelerator functionality targeted at the radiotherapy clinic level. The purpose of this work is to describe a simulation environment for medical linear accelerators with the purpose of teaching linear accelerator physics. Methods: Varian type lineacs were simulated. Klystron saturation and peak output were modelled analytically. The energy gain of an electron beam was modelled using load line expressions. The bending magnet was assumed to be a perfect solenoid whose pass through energy varied linearly with solenoid current. The dose rate calculated at depth in water was assumed to be a simple function of the target's beam current. The flattening filter was modelled as an attenuator with conical shape, and the time-averaged dose rate at a depth in water was determined by calculating kerma. Results: Fifteen analytical models were combined into a single model called SIMAC. Performance was verified systematically by adjusting typical linac control parameters. Increasing klystron pulse voltage increased dose rate to a peak, which then decreased as the beam energy was further increased due to the fixed pass through energy of the bending magnet. Increasing accelerator beam current leads to a higher dose per pulse. However, the energy of the electron beam decreases due to beam loading and so the dose rate eventually maximizes and the decreases as beam current was further increased. Conclusion: SIMAC can realistically simulate the functionality of a linear accelerator. It is expected to have value as a teaching tool for both medical physicists and linear accelerator service personnel.

43 PARTICLE ACCELERATORS↗

On the Intracenter Relaxation of Shallow Arsenic Donors in Stressed Germanium. Population Inversion under Optical Excitation

The relaxation rates of lower excited states 1s(T), 2p{sub 0}, 2s, 3p{sub 0}, and 2p{sub ±} of arsenic donors in a germanium crystal are calculated upon the interaction with long-wavelength acoustic phonons depending on the uniaxial stress in the crystallographic direction [111]. The populations of states under optical excitation are estimated for calculated times. It is shown theoretically that optical excitation of the medium forms an inverse population of arsenic donor levels and leads to the possibility of the implementation of a four-level laser scheme with the radiative transition between 2p states and the 1s triplet state at zero strain. The estimated value of the expected gain in the medium under optical excitation conditions by CO{sub 2} laser radiation in the medium at a donor concentration of 2 × 10{sup 15} cm{sup –3} is ~0.35 cm{sup –1} at a frequency of 1.98 THz if the laser transition is 2p{sub ±} → 1s(T) and 1.25 THz if the laser transition is 2p{sub 0} → 1s(T).

36 MATERIALS SCIENCE↗

Search for standard model production of four top quarks with same-sign and multilepton final states in proton–proton collisions at $\sqrt{s} = 13\,\text {TeV} $

A search for standard model production of four top quarks ( $\mathrm {t}\overline{\mathrm {t}} \mathrm {t}\overline{\mathrm {t}} $ ) is reported using events containing at least three leptons ( $\mathrm {e}, \mathrm {\mu }$ ) or a same-sign lepton pair. The events are produced in proton–proton collisions at a center-of-mass energy of 13 $\,\text {TeV}$ at the LHC, and the data sample, recorded in 2016, corresponds to an integrated luminosity of 35.9 $\,\text {fb}^{-1}$ . Jet multiplicity and flavor are used to enhance signal sensitivity, and dedicated control regions are used to constrain the dominant backgrounds. The observed and expected signal significances are, respectively, 1.6 and 1.0 standard deviations, and the $\mathrm {t}\overline{\mathrm {t}} \mathrm {t}\overline{\mathrm {t}} $ cross section is measured to be $16.9^{+13.8-11.4}$ $\,\text {fb}$ , in agreement with next-to-leading-order standard model predictions. These results are also used to constrain the Yukawa coupling between the top quark and the Higgs boson to be less than 2.1 times its expected standard model value at 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On Leakage Current Measured at High Cell Voltages in Lithium-Ion Batteries

In this study, parasitic side reactions in lithium-ion batteries were examined experimentally using a potentiostatic hold at high cell voltage. The experimental leakage current measured during the potentiostatic hold was compared to the Tafel expression and showed poor agreement with the expected transfer coefficient values, indicating that a more complicated expression could be needed to accurately capture the physics of this side reaction. Here we show that cross-talk between the electrodes is the primary contribution to the observed leakage current after the relaxation of concentration gradients has ceased. This cross-talk was confirmed with experiments using a lithium-ion conducting glass ceramic (LICGC) separator, which has high conductance only for lithium cations. The cells with LICGC separators showed significantly less leakage current during the potentiostatic hold test compared to cells with standard microporous separators where cross-talk is present. In addition, direct-current pulse power tests show an impedance rise for cells held at high potentials and for cells held at high temperatures, which could be attributed to film formation from the parasitic side reaction. Based on the experimental findings, a phenomenological mechanism is proposed for the parasitic side reaction which accounts for cross-talk and mass transport of the decomposition products across the separator.

25 ENERGY STORAGE↗

Quantifying irradiation defects in zirconium alloys: a comparison between transmission electron microscopy and whole-pattern diffraction line-profile analysis - 2016-0089

Irradiation-induced dislocations significantly affect the mechanical properties of zirconium alloys, altering slip and influencing creep and growth. Thus, the quantitative characterization of irradiation defects as a function of fluence, cold work, and/or thermal treatments is important for models that attempt to predict their impact on properties. Whole-pattern diffraction line-profile analysis (DLPA) is a well-established modern tool for microstructure characterization based on first-principle physical models for dislocation density measurements in plastically deformed materials. However, applying these DLPA methods directly to irradiated materials yields higher than expected dislocation density values compared with historical transmission electron microscopy (TEM) measurements and past line-broadening analysis studies calibrated to TEM observations. In an effort to understand these differences, a new microstructural model was developed for DLPA to specifically address dislocation structures consisting of elliptical - and -component loops. To compare the refined DLPA method with TEM measurements, high-resolution neutron diffraction patterns on nonirradiated and irradiated Zr-2.5Nb samples were collected with the Neutron Powder Diffractometer instrument at the Los Alamos Neutron Science Center and were evaluated. High-resolution TEM measurements were performed at the Reactor Materials Testing Laboratory, Queen's University, for comparison with the DLPA results. The capabilities and inherent uncertainties of both the refined DLPA and TEM methods are compared and discussed in detail. We show that the differences between the density values provided by DLPA and TEM are inherent to the methods and can be reconciled with the interpretation of the data. (authors)

36 MATERIALS SCIENCE↗

Characterization and evaluation of caustic wash tank and solvent hold tank samples from MCU from august to september 2011

During processing of Salt Batches 3 and 4 in the Modular Caustic-Side Solvent Extraction Unit (MCU), the decontamination efficiency for cesium declined from historical values and from expectations based on laboratory testing. This report documents efforts to analyze samples of solvent and process solutions from MCU in an attempt to understand the cause of the reduced performance and to recommend mitigations. CWT Solutions from MCU from the time period of variable decontamination factor (DF) performance which covers from April 2011 to September 2011 (during processing of Salt Batch 4) were examined for impurities using chromatography and spectroscopy. The results indicate that impurities were found to be of two types: aromatic containing impurities most likely from Modifier degradation and aliphatic type impurities most likely from Isopar{reg_sign} L and tri-n-octylamine (TOA) degradation. Caustic washing the Solvent Hold Tank (SHT) solution with 1M NaOH improved its extraction ability as determined from {sup 22}Na uptake tests. Evidence from this work showed that pH variance in the aqueous solutions within the range of 1M nitric acid to 1.91M NaOH that contacted the solvent samples does not influence the analytical determination of the TOA concentration by GC-MS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Polarized 3He gas circulating technologies for neutron analyzers

We outline our project to develop a circulating polarized helium-3 system for developing of large, quasi-continuously operating neutron analyzers. The project consisted of four areas: 1) Development of robust external cavity narrowed diode laser output with spectral line width < 0.17 nm and power of 2000 W. 2) Development of large glass polarizing cells using cell surface treatments to obtain long relaxation lifetimes. 3) Refinements of the circulation system with an emphasis on gas purification and materials testing. 4) Design/fabrication of a new polarizer system. 5) Preliminary testing of the new polarizer. 1. Developed Robust High-Power Narrowed Laser The optical configuration of the laser was discussed in the proposal and will be reviewed in the body of this report. The external cavity is configured to mutually lock the wavelength of five 10-bar laser stacks. All the logistical milestones were been met and critical subsystems- laser stack manifold and power divider, external laser cavity, and output telescope- were assembled and tested at low power. Each individual bar is narrowed to ~0.05 nm; when combined the laser has a cumulative spectral width of 0.17 nm across the entire beam due to variations of the bars central wavelength by +/- 0.1 nm, which is similar to that of Volume Bragg Grating narrowed laser bars. This configuration eliminates the free-running “pedestal” that occurs in other external cavity diode lasers. The full-scale laser was completed in 2016 and was used in both the older and newer helium polarizers. This laser was operated at 75% power for periods of up to 8 hours. Once installed, the spectrum became slightly broader (~.25 nm) at full power; this is likely due to very slight misalignments that occurred during handling. 2. Developed the processes to create uniform sintered sol-gel coatings. Our work on cell development comprised: 1) Production of large GE180 cells and explore different means of cell preparation, and 2) Development of apply sol-gel coatings to the interior of both borosilicate and aluminosilicate cells. We applied six sol-gel coatings. By modifying the mixture and developing procedures to drain and dry the cell, we produced visually uniform coatings on the interior of the cells. We now have perfected that process as described below in our report. We were able to accelerate the testing of cells using an ex situ method that avoids installing each cell into a polarizer. In the project’s last year, we conducted 38 external tests of 8 different cells. We also installed two sol-gel coated cells in our polarizers. We created cell with long ex situ relaxation lifetimes, one of which exceeded 40 hours. However, when installed in the polarizer the measured lifetime is 8 hours or less. 3. Demonstrated cycling of polarized gas and ex situ cell testing We are now cycling polarized gas from the polarizer to glass vessels and back. This has allowed us, for the first time, to make ex situ T1 measurements of polarizing cells without installing them into the polarizer itself. This has greatly improved our productivity in producing cells and evaluating our cell preparation processes. We continued development of the gas handling system in parallel with fabricating new polarizer. The integrated system was tested by the end of 2016. We now regularly cycle gas into and out of the polarizer. 4. Completed new polarizer infrastructure and control systems. We completed the new polarizer infrastructure in November 2016. The polarizer subsystems are 1) the frame, 2) the oil flow system, 3) the gas handling system, 4) the pressure vessel, with embedded solenoid, 5) cell mounting hardware with heat spreaders, and 6) electrical power and instrumentation. 5. Carried out initial tests of polarizer. We completed initial testing of the polarizer in April and May of 2017. These tests were carried out for periods up to 6 hours with laser power between 750 and 1300 Watts. The laser performed well and the polarization with asymptotic to 45 percent, which was below expectations. This low value resulted from a stationary thermal inversion in the cell that caused most of the laser power to be absorbed near the laser inlet window and deprived the lower portions of the cell of pumping laser light. Possible solutions to this problem include enhanced cooling of the cell near the laser entry and slight detuning of the laser. 6. Ongoing work. Our polarizer development efforts are ongoing to pursue our interest in neutron analyzers, nuclear targets, and providing helium for medical imaging. Current tests in the pipeline include: 1. Testing cooling enhancements to improve laser penetration of spectrally narrow lasers; 2. Testing of a cell with isolation valves that minimizes diffusive contact with gas handling hardware during polarization; 3. Testing of smaller hybrid cells with reduced alkali loading; 4. Producing polarized helium-3 for MRI imaging at the University of Missouri.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity Analysis of Particle-In-Cell Modeling Parameters in Settling Bed, Bubbling Fluidized Bed and Circulating Fluidized Bed

The objective of the work presented is to perform a preliminary sensitivity analysis of particle-in-cell (PIC) model parameters when applied to settling bed, bubbling fluidized bed, and circulating fluidized bed simulations. These examples correspond to widely different flow conditions commonly seen in chemical engineering applications. Simulations were performed using the PIC method in the open-source software Multiphase Flow with Interphase eXchanges (MFiX) developed by the National Energy Technology Laboratory (NETL). As part of the non-intrusive uncertainty quantification (UQ) analysis, simulation campaigns were generated using Nodeworks. Sampling locations or settings for PIC model parameters were determined using the Latin Hypercube method. Response surfaces were created using radial basis functions (RBF), and Sobol’ indices were estimated to quantify the influence of model parameters on the quantities of interest (QoI). This study marks a first step towards systematically determining optimal ranges for model parameters used in MFiX-PIC. Based on limited experience, it is expected that these values would depend strongly on flow conditions. Given the complexity of the multiphase flow systems under analysis, a non-intrusive UQ based approach is used to identify the most influential parameters in each case. This prior knowledge will help in proposing an effective design of experiments (DoE) and determine optimal parameters through techniques such as deterministic or Bayesian calibration, which will be pursued in the future.

42 ENGINEERING↗

Improving the Advancement of Women in Computer and Computational Science Research with the CRA-W Career Mentoring Workshops (Final Report)

The mission of the Computing Research Association’s Committee on Widening Participation in Computing Research (CRA-WP) is to widen the participation and improve the access, opportunities, and positive experiences of individuals from groups underrepresented in computing research and education. CRA-WP programs serve this overarching goal at all career stages; in addition, CRA-WP, through the formation of the CRA Center for Evaluating the Research Pipeline (CERP), has developed a methodology for thoroughly evaluating the success of its programs by comparing a nationwide sample of students, researchers, and faculty (non-participants) to program participants. Achieving these objectives requires that an increasing number of individuals from populations underrepresented in computing start and progress to the next stage while understanding and supporting the myriad computing pathways. CRA-WP offers programs for participants from undergraduate to senior professional levels. Different career stages need different types of interventions, and the goal of all Alliance program activities can be described within the unifying framework of Social Cognitive Career Theory, which finds that interest in and choice of a particular career path will be increased by interventions that improve one or more of the following: (1) outcome expectations (understanding and valuing the rewards of a particular outcome), (2) self-efficacy (a belief that one can successfully achieve an outcome), and (3) social supports that help one persist and overcome obstacles.

97 MATHEMATICS AND COMPUTING↗

Deflagration to Detonation Transition Update: XDDT Code Modularization

A legacy FORTRAN 77 implementation of the Baer–Nunziato two-phase mixture theory for deflagration-to-detonation transition (DDT) in reactive granular materials—hereafter the XDDT (eXplosive DDT) code—has been modularized to Fortran 90 with modular structure, external input files, and adaptive mesh capability. During validation, two code defects were identified and corrected: an inconsistency in the nodal solid pressure evaluation and a nonphysical burn-front tracking criterion. The ignition criterion was also corrected to use the granular surface temperature from the interface heat transfer model, matching the original Baer implementation. An initial attempt to validate against Figure 3 of the original Baer and Nunziato (1986) paper revealed that the code’s detonation velocity on a 201-node mesh (5.5 km/s) was approximately 21% below the expected Chapman–Jouguet value for 70% TMD HMX (∼7 km/s). Validation was redirected to the piston-driven DDT experiments of McAfee et al. (1989), Shot B-9036, for which well-characterized ionization-pin data are available. With the compaction-burn coefficient calibrated to 𝐶 𝛼 = 75, the XDDT code reproduces the DDT transition time to within 0.4% and produces a steady-state detonation velocity within 4% of the McAfee experimental value of 6.36 km/s. The burn model was generalized to support pressure-dependent exponents, enabling application to nitrocellulose-based ball propellants (TS3659) with a cube-root pressure dependence. Validation against the Sandusky/Baer PDC82 piston-impact experiment yielded a reactive wave velocity of 2.3–2.8 km/s, in good agreement with the experimental value of ∼2.2 km/s, and wave coalescence within 5% of the experimental timing. The mathematical model, input parameter requirements, and a roadmap for extending XDDT to PETN with an autocatalytic burn model are presented.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Implementation of strength and burn models for plastic-bonded explosives and propellants

We have implemented the burn model in LS-DYNA. At present, the damage (porosity and specific surface area) is specified as initial conditions. However, history variables that are used by the strength model are reserved as placeholders for the next major revision, which will be a completely interactive model. We have implemented an improved strength model for explosives based on a model for concrete. The model exhibits peak strength and subsequent strain softening in uniaxial compression. The peak strength increases with increasing strain rate and/or reduced ambient temperature. Under triaxial compression compression, the strength continues to increase (or at least not decrease) with increasing strain. This behaviour is common to both concrete and polymer-bonded explosives (PBX) because the microstructure of these composites is similar. Both have aggregate material with a broad particle size distribution, although the length scale for concrete aggregate is two orders of magnitude larger than for PBX. The (cement or polymer) binder adheres to the aggregate, and is both pressure and rate sensitive. There is a larger bind binder content in concrete, compared to the explosive, and the aggregates have different hardness. As a result we expect the parameter values to differ, but the functional forms to be applicable to both. The models have been fit to data from tests on an AWE explosive that is HMX based. The decision to implement the models in LS-DYNA was based on three factors: LS-DYNA is used routinely by the AWE engineering analysis group and has a broad base of experienced users; models implemented in LS-DYNA can be transferred easily to LLNL's ALE 3D using a material model wrapper developed by Rich Becker; and LS-DYNA could accommodate the model requirements for a significant number of additional history variables without the significant time delay associated with code modification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision Measurements of Tau Lepton Decays

Using data collected with the BABAR detector at the SLAC PEP-II electron-positron storage ring operating at a centre-of-mass energy near 10.58 GeV, the branching fractions B(τ - → π - π - π + ντ) =(8.83±0.01±0.13)%, B(τ - → K - π - π + ντ) =(0.273± 0.002 ± 0.009)%, B(τ - → K - π - K+ντ) =(0.1346 ± 0.0010 ± 0.0036)%, and B(τ - → K - K - K+ντ) =(1.58 ± 0.13 ± 0.12) × 10 -5 are measured where the uncertainties are statistical and systematic, respectively. The invariant mass distribution for the τ - → π - π - π+ντ , τ - → K - π - π+ντ , τ - → K - π - K+ντ and τ - → K - K - K+ντ decays are unfolded to correct for detector effects. A measurement of B(τ - → φπ - ντ ) =(3.42±0.55±0.25)×10 -5 , a measurement of B(τ - → φK - ντ) =(3.39±0.20±0.28)× 10 -5 and an upper limit on B(τ - → K - K - K+ντ [ex.φ]) ≤ 2.5 × 10 -6 @90%CL are determined from a binned maximum likelihood fit of the τ - → K - π - K+ντ and τ - → K - K - K+ντ K+K - invariant mass distributions. The branching ratio B(τ - →K - ν τ )/ B(τ - →π - ν τ ) is measured to be (6.531±0.056±0.093)×10 -2 from which |Vus| is determined to be 0.2255 ± 0.0023. The branching ratio B(τ - →μ - ν τ $\bar{v}$ μ )/ B(τ - →e - ν τ $\bar{v}$ e ) =(9.796 ± 0.016 ± 0.035) × 10 -1 is measured enabling a precision test of the Standard Model assumption of charged current lepton universality, gμ ge =1.0036 ± 0.0020. The branching ratios B(τ - →K - ν τ ) /B(τ - →e - ν τ $\bar{v}$ e ) =(3.882 ± 0.032 ± 0.057) × 10 -2 , and B(τ - →π - ντ ) /B(τ - →e - ν τ $\bar{v}$ e ) =(5.945 ± 0.014 ± 0.061) × 10 -1 are measured which provide additional tests of charged current lepton universality, g τ /g μ π = 0.9856 ± 0.0057 and g τ /g μ K = 0.9827 ± 0.0086 which can be combined to give g τ /g μ π/K = 0.9850 ± 0.0054 . Any deviation of these measurements from the expected Standard Model values would be an indication of new physics.

43 PARTICLE ACCELERATORS↗