Pressure Response Optimization of an Eddy Current-Driven Flyer Plate Valve for the ITER Shattered Pellet Injection System

One technique for mitigating disruptions in a tokamak is shattered pellet injection (SPI). SPI is a process in which a large solid pellet consisting of deuterium, neon, or argon is desublimated in a pipe gun barsrel and launched downstream. Pellets are shattered just before entering the plasma by an impact with an angled tube. Injection of these materials into the plasma radiates stored thermal energy, limits current decay rates, suppresses the generation of runaway electrons, and dissipates runaway electrons if necessary. A critical element of the SPI system is a fast-acting valve that releases high-pressure gas to dislodge and accelerate pellets directly, or indirectly via a mechanical punch. A prototype valve sized for the ITER SPI system has been designed and fabricated. A pulsed high-voltage power supply energizes the valve’s internal magnetic coil, which induces eddy currents in the adjacent flyer plate resulting in a repulsive force between the flyer plate and the coil. The flyer plate action lifts a valve seat, allowing high-pressure gas to flow from the valve plenum to the downstream (breech) location of the pellet or mechanical punch. All of the valve’s internal components are designed to operate in ITER-level static background magnetic fields. Here, a study was conducted to optimize the downstream pressure response for a range of valve sizes and operating pressures. In particular, the study analyzes the breech pressure response associated with varying plenum pressures as well as varying breech volumes. A computational fluid dynamics simulation was built in STAR-CCM+ and validated against data from laboratory experiments. The resulting simulation outputs, in the form of downstream responses for a variety of initial plenum pressures and breech volumes, will be used as a complement to experimental data to ensure the pressure pulse is suitable for pellet survivability. These data, combined with studies on pellet shear strength and shock response, will be applied to optimization of overall operating parameters of the ITER SPI system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WE-G-17A-09: Novel Magnetic Shielding Design for Inline and Perpendicular Integrated 6 MV Linac and 1.0 T MRI Systems

Purpose: The influence of fringe magnetic fields delivered by magnetic resonance imaging (MRI) on the beam generation and transportation in Linac is still a major challenge for the integration of linear accelerator and MRI (Linac-MRI). In this study, we investigated an optimal magnetic shielding design for Linac-MRI and further characterized the beam trajectory in electron gun. Methods: Both inline and perpendicular configurations were analyzed in this study. The configurations, comprising a Linac-MRI with a 100cm SAD and an open 1.0 T superconductive magnet, were simulated by the 3D finite element method (FEM). The steel shielding around the Linac was included in the 3D model, the thickness of which was varied from 1mm to 20mm, and magnetic field maps were acquired with and without additional shielding. The treatment beam trajectory in electron gun was evaluated using OPERA 3d SCALA with and without shielding cases. Results: When Linac was not shielded, the uniformity of diameter sphere volume (DSV) (30cm) was about 5 parts per million (ppm) and the fringe magnetic fields in electron gun were more than 0.3 T. With shielding, the magnetic fields in electron gun were reduced to less than 0.01 T. For the inline configuration, the radial magnetic fields in the Linac were about 0.02T. A cylinder steel shield used (5mm thick) altered the uniformity of DSV to 1000 ppm. For the perpendicular configuration, the Linac transverse magnetic fields were more than 0.3T, which altered the beam trajectory significantly. A 8mm-thick cylinder steel shield surrounding the Linac was used to compensate the output losses of Linac, which shifted the magnetic fields' uniformity of DSV to 400 ppm. Conclusion: For both configurations, the Linac shielding was used to ensure normal operation of the Linac. The effect of magnetic fields on the uniformity of DSV could be modulated by the shimming technique of the MRI magnet. NIH/NIGMS grant U54 GM104944, Lincy Endowed Assistant Professorship.

43 PARTICLE ACCELERATORS↗

Site Environmental Report for 2018 Sandia National Laboratories, California

Sandia National Laboratories, California (SNL/CA) is a Department of Energy (DOE) facility. The management and operations of the facility are under a contract with the DOE's National Nuclear Security Administration (NNSA). On May 1, 2017, the name of the management and operating contractor changed from Sandia Corporation to National Technology & Engineering Solutions of Sandia, LLC (NTESS). The DOE, NNSA, Sandia Field Office administers the contract and oversees contractor operations at the site. DOE and its management and operating contractor for Sandia are committed to safeguarding environmental protection, compliance, and sustainability and to ensuring the validity and accuracy of the monitoring data presented in this Annual Site Environmental Report. This Site Environmental Report for 2018 was prepared in accordance with DOE Order 231.1 B, Environment, Safety and Health Reporting (DOE 2012). The report provides a summary of environmental monitoring information and compliance activities that occurred at SNL/CA during calendar year 2018, unless noted otherwise. General site and environmental program information is also included.

54 ENVIRONMENTAL SCIENCES↗

Site Environmental Report for Sandia National Laboratories California (2019)

Sandia National Laboratories, California (SNL/CA) is a Department of Energy (DOE) facility. The management and operations of the facility are under a contract with the DOE's National Nuclear Security Administration (NNSA). On May 1, 2017, the name of the management and operating contractor changed from Sandia Corporation to National Technology & Engineering Solutions of Sandia, LLC (NTESS). The DOE, NNSA, Sandia Field Office administers the contract and oversees contractor operations at the site. DOE and its management and operating contractor for Sandia are committed to safeguarding environmental protection, compliance, and sustainability and to ensuring the validity and accuracy of the monitoring data presented in this Annual Site Environmental Report. This Site Environmental Report for 2019 was prepared in accordance with DOE Order 231.1B, Environment, S afro and Health &potting (DOE 2012). The report provides a summary of environmental monitoring information and compliance activities that occurred at SNL/CA during calendar year 2019, unless noted otherwise. General site and environmental program information is also included.

54 ENVIRONMENTAL SCIENCES↗

Site Environmental Report for 2020, Sandia National Laboratories, California

Sandia National Laboratories, California (SNL/CA) is a Department of Energy (DOE) facility. The management and operations of the facility are under a contract with the DOE's National Nuclear Security Administration (NNSA). On May 1, 2017, the name of the management and operating contractor changed from Sandia Corporation to National Technology & Engineering Solutions of Sandia, LLC (NTESS). The DOE, NNSA, Sandia Field Office administers the contract and oversees contractor operations at the site. DOE and its management and operating contractor for Sandia are committed to safeguarding environmental protection, compliance, and sustainability and to ensuring the validity and accuracy of the monitoring data presented in this Annual Site Environmental Report. This Site Environmental Report for 2020 was prepared in accordance with DOE Order 231.1B, Environment, Safety and Health Reporting (DOE 2012). The report provides a summary of environmental monitoring information and compliance activities that occurred at SNL/CA during calendar year 2020, unless noted otherwise. General site and environmental program information is also included.

54 ENVIRONMENTAL SCIENCES↗

A path to stable low-torque plasma operation in ITER with test blanket modules

New experiments in the low-torque ITER Q = 10 scenario on DIII-D demonstrate that n = 1 magnetic fields from a single row of ex-vessel control coils enable operation at ITER performance metrics in the presence of applied non-axisymmetric magnetic fields from a test blanket module (TBM) mock-up coil. With n = 1 compensation, operation below the ITER-equivalent injected torque is successful at three times the ITER equivalent toroidal magnetic field ripple for a pair of TBMs in one equatorial port, whereas the uncompensated TBM field leads to rotation collapse, loss of H-mode and plasma current disruption. In companion experiments at high plasma beta, where the n = 1 plasma response is enhanced, uncorrected TBM fields degrade energy confinement and the plasma angular momentum while increasing fast ion losses; however, disruptions are not routinely encountered owing to increased levels of injected neutral beam torque. In this regime, n = 1 field compensation leads to recovery of a dominant fraction of the TBM-induced plasma pressure and rotation degradation, and an 80% reduction in the heat load to the first wall. These results show that the n = 1 plasma response plays a dominant role in determining plasma stability, and that n = 1 field compensation alone not only recovers most of the impact on plasma performance of the TBM, but also protects the first wall from potentially damaging heat flux. Despite these benefits, plasma rotation braking from the TBM fields cannot be fully recovered using standard error field control. Lastly, given the uncertainty in extrapolation of these results to the ITER configuration, it is prudent to design the TBMs with as low a ferromagnetic mass as possible without jeopardizing the TBM mission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operator learning for energy-efficient building ventilation control with computational fluid dynamics simulation of a real-world classroom

Energy-efficient ventilation control plays an important role in reducing building energy consumption while ensuring occupant health and comfort. While Computational Fluid Dynamics (CFD) simulations provide detailed and physically accurate representations of indoor airflow, their high computational cost limits their use in real-time building control. In this work, we present a neural operator learning framework that combines the physical accuracy of CFD with the computational efficiency of machine learning to enable building ventilation control with the high-fidelity fluid dynamics models. Our method jointly optimizes the airflow supply rates and vent angles to reduce energy use and adhere to air quality constraints. We train an ensemble of neural operator transformer models to learn the mapping from building control actions to airflow fields using high-resolution CFD data. This learned neural operator is then embedded in an optimization-based control framework for building ventilation control. Experimental results show that our approach achieves significant energy savings compared to maximum airflow rate control, rule-based control, as well as data-driven control methods using spatially averaged CO 2 prediction and deep learning–based reduced-order models, while consistently maintaining safe indoor air quality. These results highlight the practicality and scalability of our method in maintaining energy efficiency and indoor air quality in real-world buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiofrequency hydrogen ion source with permanent magnets providing axial magnetic field

Uniform axial magnetic field of about 70 G is applied to a radiofrequency (rf) hydrogen ion source by arrays of permanent magnets. The plasma density and electron temperature downstream of the source and near the magnetic filter are compared with those in the previously described ion source, where the axial field has been applied by two solenoids. The source is operated at ∼350 kHz and above 10 kW rf power with a field-effect-transistor-based invertor power supply in 1.5 Pa hydrogen. The results show that the plasma density of ∼10{sup 19} m{sup −3} near the source exit and ∼10{sup 18} m{sup −3} near the magnetic filter can be obtained, which are higher than those with the solenoids.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of Electrochemically-Driven CO 2 Separation Using Hydroxide Exchange Membranes

Hydroxide exchange membrane fuel cells (HEMFCs) are a potentially lower-cost hydrogen fuel cell technology; however, ambient levels of CO 2 in air significantly reduce HEMFCs’ performance. In this work, we demonstrate an electrochemically-driven CO 2 separator (EDCS) which can be used to remove ambient levels of CO 2 from air upstream of the HEMFC stack in fuel cell vehicles, protecting it from CO 2 -related performance losses. The EDCS operating window was explored for current density, anode flow, and cathode flow with respect to its impact on CO 2 separation performance. Additionally, gas-phase mass transport was improved by selecting flow fields and gas diffusion layers conducive to the EDCS operating regime. The use of a carbon-ionomer interlayer at the cathode was explored and improved CO 2 removal performance from 77.7% to 98.2% at 20 mA cm −2 . An analytical, 1-D model is used to explain the experimental observations and design improvements. A single-cell, 25 cm 2 EDCS using the aforementioned improved design demonstrated greater than 98% CO 2 removal at a cathode flow rate of 1300 sccm for 100 h with 2.7% hydrogen stack consumption.

Matz, Stephanie↗

Field-dependent carrier transport in implanted isolation region of GaN lateral power devices

Among GaN lateral power devices, with proper E-field management, the breakdown occurs in the device isolation region rather than the active region. In this paper, we investigate field-dependent carrier transport in the isolation structures. Isolation test structures with variations in buffer doping, un-intentionally doped (UID) GaN thickness, and implantation conditions were fabricated. Electrical characterization was performed over a wide range of voltage and temperature. With varying UID GaN thickness and buffer doping, the leakage current and breakdown characteristics remain the same for a specific implantation condition, indicating that the leakage conduction and breakdown are governed by the implanted GaN region. Analysis of the temperature-dependent I–V reveals that carrier transport in the implanted GaN can be well explained by hopping conduction, involving three distinctive regions of operation depending on the E-field. At low E-field, carrier transport is ohmic, consistent with variable range hopping, driven by thermal activation. At medium E-field, a field enhanced thermally activated hopping is observed, following σ ∼ σ(T)exp(E). At high E-field, activation-less hopping is visible, following σ ∼ exp(−1/E), which occurs above a critical E-field limited by localization length.

Sadek, Mansura (ORCID:0000000322588338)↗

Measurement of the internal stress and electric field in a resonating piezoelectric transformer for high-voltage applications using the electro-optic and photoelastic effects

The high output voltages from piezoelectric transformers are currently being used to accelerate charged particle beams for x-ray and neutron production. Traditional methods of characterizing piezoelectric transformers (PTs) using electrical probes can decrease the voltage transformation ratio of the device due to the introduction of load impedances on the order of hundreds of kiloohms to hundreds of megaohms. Consequently, an optical diagnostic was developed that used the photoelastic and electro-optic effects present in piezoelectric materials that are transparent to a given optical wavelength to determine the internal stress and electric field. The combined effects of the piezoelectric, photoelastic, and electro-optic effects result in a time-dependent change the refractive indices of the material and produce an artificially induced, time-dependent birefringence in the piezoelectric material. This induced time-dependent birefringence results in a change in the relative phase difference between the ordinary and extraordinary wave components of a helium-neon laser beam. The change in phase difference between the wave components was measured using a set of linear polarizers. The measured change in phase difference was used to calculate the stress and electric field based on the nonlinear optical properties, the piezoelectric constitutive equations, and the boundary conditions of the PT. Maximum stresses of approximately 10 MPa and electric fields of as high as 6 kV/cm were measured with the optical diagnostic. Measured results were compared to results from both a simple one-dimensional (1D) model of the piezoelectric transformer and a three-dimensional (3D) finite element model. Measured stresses and electric fields along the length of an operating length-extensional PT for two different electrical loads were within at least 50 % of 3D finite element simulated results. Additionally, the 3D finite element results were more accurate than the results from the 1D model for a wider range of electrical load impedances under test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time Monitoring of Selenium Species in Power Plant Wastewaters via Optical Spectroscopy

Energy Research Company (ERCo) and Lehigh University are developing a new rapid sensor for measuring trace amounts of selenium in coal-fired power plant wastewater streams down to the single parts-per-billion (ppb) level. With EPA regulations pending on releases of selenium in wastewaters from power plants, plant operators are finding that commercially available technology is not suitable for ensuring compliance with the new regulations. These regulations require monitoring selenium at the single ppb level. There are several important advantages of our instrument as compared to other potential methods such as ICP-MS or ICP-OES. First, the method is rapid, allowing for analyses within minutes. Second, the method is amenable to automation, so dedicated lab personnel are not required. Third, the apparatus is compact and comprised of off-the-shelf components that are inexpensive compared to other laboratory instruments. Fourth, our instrument is designed to be used in the field and will collect data from any water source in near real time. Fifth, maintenance is minimal and finally, the cost is quite low. Furthermore, selective concentration of different ionization states of selenium was also demonstrated. Selenium is present in wastewaters in two main ionization states, +4 and +6. The fraction of each ionization state is important to know because it affects selenium treatment technologies. We were able to measure each one with a single instrument. The Phase II work plan will automate our instrument and expand the measurements to other heavy metals such as mercury and arsenic, the two other heavy metals covered in the new EPA regulations. We will also field test the instrument at an operating coal fired power plant.

20 FOSSIL-FUELED POWER PLANTS↗

Higher derivatives and power spectrum in effective single field inflation

We study next-to-leading corrections to the effective action of the curvature perturbation obtained by integrating out the coupled heavy isocurvature perturbation. These corrections result from including higher order derivative operators, weighted by the mass scale of the heavy physics, in the effective theory expansion. We find that the correction terms are suppressed by the ratio of the Hubble parameter to the heavy mass scale. The corresponding corrections to the power spectrum of the curvature perturbation are presented for a simple illustrative example.

79 ASTRONOMY AND ASTROPHYSICS↗

Improving the radiation hardness of graphene field effect transistors

Ionizing radiation poses a significant challenge to the operation and reliability of conventional silicon-based devices. In this paper, we report the effects of gamma radiation on graphene field-effect transistors (GFETs), along with a method to mitigate those effects by developing a radiation-hardened version of our back-gated GFETs. We demonstrate that activated atmospheric oxygen from the gamma ray interaction with air damages the semiconductor device, and damage to the substrate contributes additional threshold voltage instability. Our radiation-hardened devices, which have protection against these two effects, exhibit minimal performance degradation, improved stability, and significantly reduced hysteresis after prolonged gamma radiation exposure. Finally, we believe this work provides an insight into graphene's interactions with ionizing radiation that could enable future graphene-based electronic devices to be used for space, military, and other radiation-sensitive applications.

36 MATERIALS SCIENCE↗

Chasing Fast Dynamos in the Plasma Lab

Self-generating magnetic field research is performed through the operation of the newly built Madison Plasma Dynamo Experiment (MPDX). MPDX is designed to explore a hitherto unexplored part of parameter space where dynamos operate in nature. Dynamos are systems which continuously transform kinetic energy from plasma flow into magnetic energy. Before this project, MPDX had demonstrated the ability to create steady-state, unmagnetized high conductivity, low viscosity plasmas in the lab and shown that sheared flows can be driven from the plasma boundary using an electrostatic stirring technique; the resulting Reynolds numbers and Alfvén Mach numbers easily match those required for our dynamo scenarios. The research activities included: (1) systematic undertaking of a set of plasma hydrodynamics experiments, exploring several different flow geometries, measuring plasma viscosity, how toroidal and poloidal flows self-consistently interact, observing the transition to turbulence and experimentally understanding the boundary conditions (on flow and magnetic field) that make this system unique, (2) searching for slow, laminar dynamos, and (3) searching for fast, turbulent dynamos. Discovering the conditions under which dynamos self-generate magnetic fields and then understanding how this field changes plasma dynamics is one of the most compelling questions in all of plasma astrophysics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Improved Caprock Integrity and Risk Assessment Techniques. Final report for period Oct. 1, 2012 - Sept. 30, 2014

GeoMechanics Technologies has completed a geomechanical caprock integrity analysis and risk assessment study funded through the US Department of Energy. The project included: a detailed review of historical caprock integrity problems experienced in the natural gas storage industry; a theoretical description and documentation of caprock integrity issues; advanced coupled transport flow modelling and geomechanical simulation of three large-scale potential geologic sequestration sites to estimate geomechanical effects from CO₂ injection; development of a quantitative risk and decision analysis tool to assess caprock integrity risks; and, ultimately the development of recommendations and guidelines for caprock characterization and CO₂ injection operating practices. Historical data from gas storage operations and CO₂ sequestration projects suggest that leakage and containment incident risks are on the order of 10 -1 to 10 -2 , which is higher risk than some previous studies have suggested for CO₂. Geomechanical analysis, as described herein, can be applied to quantify risks and to provide operating guidelines to reduce risks. The risk assessment tool developed for this project has been applied to five areas: The Wilmington Graben offshore Southern California, Kevin Dome in Montana, the Louden Field in Illinois, the Sleipner CO₂ sequestration operation in the North Sea, and the In Salah CO₂ sequestration operation in North Africa. Of these five, the Wilmington Graben area represents the highest relative risk while the Kevin Dome area represents the lowest relative risk.

58 GEOSCIENCES↗

Improvement in J{sub c} performance below liquid nitrogen temperature for SmBa{sub 2}Cu{sub 3}O{sub y} superconducting films with BaHfO{sub 3} nano-rods controlled by low-temperature growth

For use in high-magnetic-field coil-based applications, the critical current density (J{sub c}) of REBa{sub 2}Cu{sub 3}O{sub y} (REBCO, where RE = rare earth) coated conductors must be isotropically improved, with respect to the direction of the magnetic field; these improvements must be realized at the operating conditions of these applications. In this study, improvement of the J{sub c} for various applied directions of magnetic field was achieved by controlling the morphology of the BaHfO{sub 3} (BHO) nano-rods in a SmBCO film. We fabricated the 3.0 vol. % BHO-doped SmBCO film at a low growth temperature of 720 °C, by using a seed layer technique (T{sub s} = 720 °C film). The low-temperature growth resulted in a morphological change in the BHO nano-rods. In fact, a high number density of (3.1 ± 0.1) × 10{sup 3} μm{sup −2} of small (diameter: 4 ± 1 nm), discontinuous nano-rods that grew in various directions, was obtained. In J{sub c} measurements, the J{sub c} of the T{sub s} = 720 °C film in all directions of the applied magnetic field was higher than that of the non-doped SmBCO film. The J{sub c}{sup min} (6.4 MA/cm{sup 2}) of the former was more than 6 times higher than that (1.0 MA/cm{sup 2}) of the latter at 40 K, under 3 T. The aforementioned results indicated that the discontinuous BHO nano-rods, which occurred with a high number density, exerted a 3D-like flux pinning at the measurement conditions considered. Moreover, at 4.2 K and under 17 T, a flux pinning force density of 1.6 TN/m{sup 3} was realized; this value was comparable to the highest value recorded, to date.

36 MATERIALS SCIENCE↗

Analysis of Defect Irrelevancy in a Non-Insulated REBCO Pancake Coil Using an Electric Network Model

High-temperature superconducting REBCO coated conductor is one of the main candidates for next-generation high field magnets in fusion reactors and particle accelerators owing to their high current-carrying capability. Although these materials can operate at higher temperatures and generate higher magnetic fields than their counterparts with lower critical temperatures, protecting the REBCO magnet against quench is challenging. A variety of candidate technologies that may be able to enable self-protection, including no-insulation technology and insulative coatings with temperature-dependent resistance, are in development. Here, in order to understand current sharing and thermal processes during a quench, we model a REBCO pancake coil as an electrical circuit, considering power generation and heat transfer along conductor turns, and study the current distribution around a local defect with lower critical current. The magnetic field and coil terminal voltage predicted by the simulation was compared to published experimental results. Our results provide useful insights into how current sharing occurs around defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗