Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gaussian Process Models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Ensemble Kalman filters for dynamical systems with unresolved turbulence

Ensemble Kalman filters are developed for turbulent dynamical systems where the forecast model does not resolve all the active scales of motion. Coarse-resolution models are intended to predict the large-scale part of the true dynamics, but observations invariably include contributions from both the resolved large scales and the unresolved small scales. The error due to the contribution of unresolved scales to the observations, called ‘representation’ or ‘representativeness’ error, is often included as part of the observation error, in addition to the raw measurement error, when estimating the large-scale part of the system. It is here shown how stochastic superparameterization (a multiscale method for subgridscale parameterization) can be used to provide estimates of the statistics of the unresolved scales. In addition, a new framework is developed wherein small-scale statistics can be used to estimate both the resolved and unresolved components of the solution. The one-dimensional test problem from dispersive wave turbulence used here is computationally tractable yet is particularly difficult for filtering because of the non-Gaussian extreme event statistics and substantial small scale turbulence: a shallow energy spectrum proportional to k{sup −5/6} (where k is the wavenumber) results in two-thirds of the climatological variance being carried by the unresolved small scales. Because the unresolved scales contain so much energy, filters that ignore the representation error fail utterly to provide meaningful estimates of the system state. Inclusion of a time-independent climatological estimate of the representation error in a standard framework leads to inaccurate estimates of the large-scale part of the signal; accurate estimates of the large scales are only achieved by using stochastic superparameterization to provide evolving, large-scale dependent predictions of the small-scale statistics. Again, because the unresolved scales contain so much energy, even an accurate estimate of the large-scale part of the system does not provide an accurate estimate of the true state. By providing simultaneous estimates of both the large- and small-scale parts of the solution, the new framework is able to provide accurate estimates of the true system state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical analysis of dose heterogeneity in circulating blood: Implications for sequential methods of total body irradiation

Purpose: Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these ''sequential'' techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Methods: Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. Results: The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than {+-}10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times. However, the EUD was unaffected (within 10%) for perfusion periods of less than 150 s or treatment times of 20 min or greater. Treatment over six fractions improved the EUD per fraction such that all parametric combinations resulted in unaffected EUD. The stochastic models confirmed these results. Conclusions: Dose heterogeneity in circulating blood cells is clinically acceptable for typical treatment times, perfusion rates, and cell types. Development of conformal, sequential TBI treatment techniques should not be withheld based on concerns over circulating blood dose heterogeneity.

60 APPLIED LIFE SCIENCES↗

A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy

Purpose: To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. Methods: Eleven patients with unresectable disease at the tonsil or base of tongue who underwent MRI, CT, and PET/CT within two months before the start of radiotherapy or chemoradiotherapy were recruited for the study. For each patient, PET/CT and T1-weighted contrast MRI scans were first registered to the planning CT using deformable and rigid registration, respectively, to resample the PET and magnetic resonance (MR) images to the planning CT space. A binary mask was manually defined to identify the tumor area. The resampled PET and MR images, the planning CT image, and the binary mask were fed into the automatic segmentation algorithm for target delineation. The algorithm was based on a multichannel Gaussian mixture model and solved using an expectation–maximization algorithm with Markov random fields. To evaluate the algorithm, we compared the multichannel autosegmentation with an autosegmentation method using only PET images. The physician-defined gross tumor volume (GTV) was used as the “ground truth” for quantitative evaluation. Results: The median multichannel segmented GTV of the primary tumor was 15.7 cm{sup 3} (range, 6.6–44.3 cm{sup 3}), while the PET segmented GTV was 10.2 cm{sup 3} (range, 2.8–45.1 cm{sup 3}). The median physician-defined GTV was 22.1 cm{sup 3} (range, 4.2–38.4 cm{sup 3}). The median difference between the multichannel segmented and physician-defined GTVs was −10.7%, not showing a statistically significant difference (p-value = 0.43). However, the median difference between the PET segmented and physician-defined GTVs was −19.2%, showing a statistically significant difference (p-value =0.0037). The median Dice similarity coefficient between the multichannel segmented and physician-defined GTVs was 0.75 (range, 0.55–0.84), and the median sensitivity and positive predictive value between them were 0.76 and 0.81, respectively. Conclusions: The authors developed an automated multimodality segmentation algorithm for tumor volume delineation and validated this algorithm for head and neck cancer radiotherapy. The multichannel segmented GTV agreed well with the physician-defined GTV. The authors expect that their algorithm will improve the accuracy and consistency in target definition for radiotherapy.

60 APPLIED LIFE SCIENCES↗

RECONSTRUCTING THE INITIAL DENSITY FIELD OF THE LOCAL UNIVERSE: METHODS AND TESTS WITH MOCK CATALOGS

Our research objective in this paper is to reconstruct an initial linear density field, which follows the multivariate Gaussian distribution with variances given by the linear power spectrum of the current cold dark matter model and evolves through gravitational instabilities to the present-day density field in the local universe. For this purpose, we develop a Hamiltonian Markov Chain Monte Carlo method to obtain the linear density field from a posterior probability function that consists of two components: a prior of a Gaussian density field with a given linear spectrum and a likelihood term that is given by the current density field. The present-day density field can be reconstructed from galaxy groups using the method developed in Wang et al. Using a realistic mock Sloan Digital Sky Survey DR7, obtained by populating dark matter halos in the Millennium simulation (MS) with galaxies, we show that our method can effectively and accurately recover both the amplitudes and phases of the initial, linear density field. To examine the accuracy of our method, we use N-body simulations to evolve these reconstructed initial conditions to the present day. The resimulated density field thus obtained accurately matches the original density field of the MS in the density range 0.3{approx}<{rho}/ {rho}-bar {approx}<20 without any significant bias. In particular, the Fourier phases of the resimulated density fields are tightly correlated with those of the original simulation down to a scale corresponding to a wavenumber of {approx}1 h Mpc{sup -1}, much smaller than the translinear scale, which corresponds to a wavenumber of {approx}0.15 h Mpc{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction

Purpose: The ionizing radiation imparted to patients during computed tomography exams is raising concerns. This paper studies the performance of a scheme called dose reduction using prior image constrained compressed sensing (DR-PICCS). The purpose of this study is to characterize the effects of a statistical model of x-ray detection in the DR-PICCS framework and its impact on spatial resolution. Methods: Both numerical simulations with known ground truth and in vivo animal dataset were used in this study. In numerical simulations, a phantom was simulated with Poisson noise and with varying levels of eccentricity. Both the conventional filtered backprojection (FBP) and the PICCS algorithms were used to reconstruct images. In PICCS reconstructions, the prior image was generated using two different denoising methods: a simple Gaussian blur and a more advanced diffusion filter. Due to the lack of shift-invariance in nonlinear image reconstruction such as the one studied in this paper, the concept of local spatial resolution was used to study the sharpness of a reconstructed image. Specifically, a directional metric of image sharpness, the so-called pseudopoint spread function (pseudo-PSF), was employed to investigate local spatial resolution. Results: In the numerical studies, the pseudo-PSF was reduced from twice the voxel width in the prior image down to less than 1.1 times the voxel width in DR-PICCS reconstructions when the statistical model was not included. At the same noise level, when statistical weighting was used, the pseudo-PSF width in DR-PICCS reconstructed images varied between 1.5 and 0.75 times the voxel width depending on the direction along which it was measured. However, this anisotropy was largely eliminated when the prior image was generated using diffusion filtering; the pseudo-PSF width was reduced to below one voxel width in that case. In the in vivo study, a fourfold improvement in CNR was achieved while qualitatively maintaining sharpness; images also had a qualitatively more uniform noise spatial distribution when including a statistical model. Conclusions: DR-PICCS enables to reconstruct CT images with lower noise than FBP and the loss of spatial resolution can be mitigated to a large extent. The introduction of statistical modeling in DR-PICCS may improve some noise characteristics, but it also leads to anisotropic spatial resolution properties. A denoising method, such as the directional diffusion filtering, has been demonstrated to reduce anisotropy in spatial resolution effectively when it was combined with DR-PICCS with statistical modeling.

60 APPLIED LIFE SCIENCES↗

Development and evaluation of a computer-aided diagnostic scheme for lung nodule detection in chest radiographs by means of two-stage nodule enhancement with support vector classification

Purpose: To develop a computer-aided detection (CADe) scheme for nodules in chest radiographs (CXRs) with a high sensitivity and a low false-positive (FP) rate. Methods: The authors developed a CADe scheme consisting of five major steps, which were developed for improving the overall performance of CADe schemes. First, to segment the lung fields accurately, the authors developed a multisegment active shape model. Then, a two-stage nodule-enhancement technique was developed for improving the conspicuity of nodules. Initial nodule candidates were detected and segmented by using the clustering watershed algorithm. Thirty-one shape-, gray-level-, surface-, and gradient-based features were extracted from each segmented candidate for determining the feature space, including one of the new features based on the Canny edge detector to eliminate a major FP source caused by rib crossings. Finally, a nonlinear support vector machine (SVM) with a Gaussian kernel was employed for classification of the nodule candidates. Results: To evaluate and compare the scheme to other published CADe schemes, the authors used a publicly available database containing 140 nodules in 140 CXRs and 93 normal CXRs. The CADe scheme based on the SVM classifier achieved sensitivities of 78.6% (110/140) and 71.4% (100/140) with averages of 5.0 (1165/233) FPs/image and 2.0 (466/233) FPs/image, respectively, in a leave-one-out cross-validation test, whereas the CADe scheme based on a linear discriminant analysis classifier had a sensitivity of 60.7% (85/140) at an FP rate of 5.0 FPs/image. For nodules classified as ''very subtle'' and ''extremely subtle,'' a sensitivity of 57.1% (24/42) was achieved at an FP rate of 5.0 FPs/image. When the authors used a database developed at the University of Chicago, the sensitivities was 83.3% (40/48) and 77.1% (37/48) at an FP rate of 5.0 (240/48) FPs/image and 2.0 (96/48) FPs /image, respectively. Conclusions: These results compare favorably to those described for other commercial and noncommercial CADe nodule detection systems.

60 APPLIED LIFE SCIENCES↗

Enhancing approximate modular Bayesian inference by emulating the conditional posterior

In modular Bayesian analyses, complex models are composed of distinct modules, each representing different aspects of the data or prior information. In this context, fully Bayesian approaches can sometimes lead to undesirable feedback between modules, compromising the integrity of the inference. The “cut-distribution” prevents unwanted influence between modules by “cutting” feedback. The direct sampling (DS) algorithm is standard practice for approximating the cut-distribution, but it can be computationally intensive, especially when the number of imputations required is large. An enhanced method is proposed, the Emulating the Conditional Posterior (ECP) algorithm, which leverages emulation to increase the number of imputations. Through numerical experiment it is demonstrated that the ECP algorithm outperforms the traditional DS approach in terms of accuracy and computational efficiency, particularly when resources are constrained. Here, it is also shown how the DS algorithm can be improved using ideas from design of experiments. Some practical recommendations are given for algorithm choice in modular Bayesian analyses.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-164: Estimation of DVH Variation for PTV Due to Interfraction Organ Motion in Prostate VMAT Using Gaussian Error Function

Purpose: We developed a method to predict the change of DVH for PTV due to interfraction organ motion in prostate VMAT without repeating the CT scan and treatment planning. The method is based on a pre-calculated patient database with DVH curves of PTV modelled by the Gaussian error function (GEF). Methods: For a group of 30 patients with different prostate sizes, their VMAT plans were recalculated by shifting their PTVs 1 cm with 10 increments in the anterior-posterior, left-right and superior-inferior directions. The DVH curve of PTV in each replan was then fitted by the GEF to determine parameters describing the shape of curve. Information of parameters, varying with the DVH change due to prostate motion for different prostate sizes, was analyzed and stored in a database of a program written by MATLAB. Results: To predict a new DVH for PTV due to prostate interfraction motion, prostate size and shift distance with direction were input to the program. Parameters modelling the DVH for PTV were determined based on the pre-calculated patient dataset. From the new parameters, DVH curves of PTVs with and without considering the prostate motion were plotted for comparison. The program was verified with different prostate cases involving interfraction prostate shifts and replans. Conclusion: Variation of DVH for PTV in prostate VMAT can be predicted using a pre-calculated patient database with DVH curve fitting. The computing time is fast because CT rescan and replan are not required. This quick DVH estimation can help radiation staff to determine if the changed PTV coverage due to prostate shift is tolerable in the treatment. However, it should be noted that the program can only consider prostate interfraction motions along three axes, and is restricted to prostate VMAT plan using the same plan script in the treatment planning system.

60 APPLIED LIFE SCIENCES↗

SU-F-T-681: Does the Biophysical Modeling for Immunological Aspects in Radiotherapy Precisely Predict Tumor and Normal Tissue Responses?

Purpose: Recent advances in immunotherapy make possible to combine with radiotherapy. The aim of this study was to assess the TCP/NTCP model with immunological aspects including stochastic distribution as intercellular uncertainties. Methods: In the clinical treatment planning system (Eclipse ver.11.0, Varian medical systems, US), biological parameters such as α/β, D50, γ, n, m, TD50 including repair parameters (bi-exponential repair) can be set as any given values to calculate the TCP/NTCP. Using a prostate cancer patient data with VMAT commissioned as a 6-MV photon beam of Novalis-Tx (BrainLab, US) in clinical use, the fraction schedule were hypothesized as 70–78Gy/35–39fr, 72–81Gy/40–45fr, 52.5–66Gy/16–22fr, 35–40Gy/5fr of 5–7 fractions in a week. By use of stochastic biological model applying for Gaussian distribution, the effects of the TCP/NTCP variation of repair parameters of the immune system as well as the intercellular uncertainty of tumor and normal tissues have been evaluated. Results: As respect to the difference of the α/β, the changes of the TCP/NTCP were increased in hypo-fraction regimens. The difference between the values of n and m affect the variation of the NTCP with the fraction schedules, independently. The elongation of repair half-time (long) increased the TCP/NTCP twice or much higher in the case of hypo-fraction scheme. For tumor, the repopulation parameters such as Tpot and Tstart, which is immunologically working to the tumor, improved TCP. Conclusion: Compared to default fixed value, which has affected by the probability of cell death and cure, hypo-fractionation schemes seemed to have advantages for the variations of the values of m. The possibility of an increase of the α/β or TD50 and repair parameters in tumor and normal tissue by immunological aspects were highly expected. For more precise prediction, treatment planning systems should be incorporated the complicated biological optimization in clinical practice combined with basic experiments data.

60 APPLIED LIFE SCIENCES↗

Parallel derivative-free optimization for simulation-based design of behind-the-meter energy systems

In this work, the integrated design and dispatch of behind-the-meter or distributed resources (e.g. stationary battery storage and solar PV generation) is considered. A simulation-based framework is employed, generating high-fidelity results with closed-loop predictive control at a fine resolution, at the expense of high computational cost (several minutes to a few hours per design point). To address this challenge, parallel derivative-free design methods are considered. Four methods are compared, including state-of-the-art surrogate-based methods (Radial-Basis Functions and Gaussian processes) and sampling strategies, an evolutionary-based method, and a simple sequential grid refinement method. As a case study, two types of design problem with increasing complexity are considered, namely, the design of behind-the-meter resources (three design variables) and the inclusion of grid capacity (four design variables). The second yields a constrained design problem for which violations can only be determined after solving the computationally expensive simulation. For the three-dimensional case, all methods present a good performance, achieving a solution within 1% of the optimum after the first iteration, with the sequential grid refinement exhibiting the fastest convergence and achieving the best final objective value. This indicates that the parallel evaluation of multiple sampling points may be more important than the choice of method for small decision spaces. For the four-dimensional constrained case, the Genetic Algorithm presents the best tradeoff between performance and computational effort, while the rough objective function terrain generated by constraint violation penalties reduces the performance of surrogate-based methods. Contour plots with flat regions indicate flexibility in the optimal design and highlight the importance of characterizing the solution space.

24 POWER TRANSMISSION AND DISTRIBUTION↗

THE MASS DISTRIBUTION OF STELLAR-MASS BLACK HOLES

We perform a Bayesian analysis of the mass distribution of stellar-mass black holes using the observed masses of 15 low-mass X-ray binary systems undergoing Roche lobe overflow and 5 high-mass, wind-fed X-ray binary systems. Using Markov Chain Monte Carlo calculations, we model the mass distribution both parametrically-as a power law, exponential, Gaussian, combination of two Gaussians, or log-normal distribution-and non-parametrically-as histograms with varying numbers of bins. We provide confidence bounds on the shape of the mass distribution in the context of each model and compare the models with each other by calculating their relative Bayesian evidence as supported by the measurements, taking into account the number of degrees of freedom of each model. The mass distribution of the low-mass systems is best fit by a power law, while the distribution of the combined sample is best fit by the exponential model. This difference indicates that the low-mass subsample is not consistent with being drawn from the distribution of the combined population. We examine the existence of a 'gap' between the most massive neutron stars and the least massive black holes by considering the value, M{sub 1%}, of the 1% quantile from each black hole mass distribution as the lower bound of black hole masses. Our analysis generates posterior distributions for M{sub 1%}; the best model (the power law) fitted to the low-mass systems has a distribution of lower bounds with M{sub 1%}>4.3 M{sub sun} with 90% confidence, while the best model (the exponential) fitted to all 20 systems has M{sub 1%}>4.5 M{sub sun} with 90% confidence. We conclude that our sample of black hole masses provides strong evidence of a gap between the maximum neutron star mass and the lower bound on black hole masses. Our results on the low-mass sample are in qualitative agreement with those of Ozel et al., although our broad model selection analysis more reliably reveals the best-fit quantitative description of the underlying mass distribution. The results on the combined sample of low- and high-mass systems are in qualitative agreement with Fryer and Kalogera, although the presence of a mass gap remains theoretically unexplained.

79 ASTRONOMY AND ASTROPHYSICS↗

Model-based PSF and MTF estimation and validation from skeletal clinical CT images

Purpose: A method was developed to correct for systematic errors in estimating the thickness of thin bones due to image blurring in CT images using bone interfaces to estimate the point-spread-function (PSF). This study validates the accuracy of the PSFs estimated using said method from various clinical CT images featuring cortical bones. Methods: Gaussian PSFs, characterized by a different extent in the z (scan) direction than in the x and y directions were obtained using our method from 11 clinical CT scans of a cadaveric craniofacial skeleton. These PSFs were estimated for multiple combinations of scanning parameters and reconstruction methods. The actual PSF for each scan setting was measured using the slanted-slit technique within the image slice plane and the longitudinal axis. The Gaussian PSF and the corresponding modulation transfer function (MTF) are compared against the actual PSF and MTF for validation. Results: The differences (errors) between the actual and estimated full-width half-max (FWHM) of the PSFs were 0.09 ± 0.05 and 0.14 ± 0.11 mm for the xy and z axes, respectively. The overall errors in the predicted frequencies measured at 75%, 50%, 25%, 10%, and 5% MTF levels were 0.06 ± 0.07 and 0.06 ± 0.04 cycles/mm for the xy and z axes, respectively. The accuracy of the estimates was dependent on whether they were reconstructed with a standard kernel (Toshiba's FC68, mean error of 0.06 ± 0.05 mm, MTF mean error 0.02 ± 0.02 cycles/mm) or a high resolution bone kernel (Toshiba's FC81, PSF FWHM error 0.12 ± 0.03 mm, MTF mean error 0.09 ± 0.08 cycles/mm). Conclusions: The method is accurate in 3D for an image reconstructed using a standard reconstruction kernel, which conforms to the Gaussian PSF assumption but less accurate when using a high resolution bone kernel. The method is a practical and self-contained means of estimating the PSF in clinical CT images featuring cortical bones, without the need phantoms or any prior knowledge about the scanner-specific parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing image quality and dose reduction of a new x-ray computed tomography iterative reconstruction algorithm using model observers

Purpose: A number of different techniques have been developed to reduce radiation dose in x-ray computed tomography (CT) imaging. In this paper, the authors will compare task-based measures of image quality of CT images reconstructed by two algorithms: conventional filtered back projection (FBP), and a new iterative reconstruction algorithm (IR). Methods: To assess image quality, the authors used the performance of a channelized Hotelling observer acting on reconstructed image slices. The selected channels are dense difference Gaussian channels (DDOG).A body phantom and a head phantom were imaged 50 times at different dose levels to obtain the data needed to assess image quality. The phantoms consisted of uniform backgrounds with low contrast signals embedded at various locations. The tasks the observer model performed included (1) detection of a signal of known location and shape, and (2) detection and localization of a signal of known shape. The employed DDOG channels are based on the response of the human visual system. Performance was assessed using the areas under ROC curves and areas under localization ROC curves. Results: For signal known exactly (SKE) and location unknown/signal shape known tasks with circular signals of different sizes and contrasts, the authors’ task-based measures showed that a FBP equivalent image quality can be achieved at lower dose levels using the IR algorithm. For the SKE case, the range of dose reduction is 50%–67% (head phantom) and 68%–82% (body phantom). For the study of location unknown/signal shape known, the dose reduction range can be reached at 67%–75% for head phantom and 67%–77% for body phantom case. These results suggest that the IR images at lower dose settings can reach the same image quality when compared to full dose conventional FBP images. Conclusions: The work presented provides an objective way to quantitatively assess the image quality of a newly introduced CT IR algorithm. The performance of the model observers using the IR images was always higher than that seen using the FBP images in the authors’ SKE and SKE location unknown detection tasks. To achieve a FBP-equivalent image quality in CT systems, the authors can lower the radiation dose by using this IR image reconstruction algorithm. Further studies are warranted using clinical data and human observer to validate these results for more complicated and realistic tasks.

60 APPLIED LIFE SCIENCES↗

2025 ASMS Investigation of the Collision-Induced Dissociation Mechanism of Protonated TODGA with IRIS

Title (20 words): Investigation of the Collision-Induced Dissociation Mechanism of Protonated TODGA with IRIS Introduction (120 words): One of the challenges facing wide-spread adoption of nuclear power is the development of efficient separation processes for used nuclear fuel. The molecules in separation processes are subjected to an extreme environment due to the high radiation fields from the used fuel and highly acidic media used for fuel dissolution, which results in significant molecular degradation, leading to reduced process efficiency. These degradation products must be identified and studied so mitigation strategies can be developed to maintain process efficiency. However, complex systems can have many degradation products, complicating identification. Untargeted analysis tools could be used to understand radiation chemistry in complex systems. However, this would necessitate improved understanding of the gas-phase fragmentation mechanisms of fuel cycle molecules like tetraoctyldiglycolamide (TODGA). Methods (120 words): The gas-phase fragmentation of protonated TODGA was investigated using collision-induced dissociation (CID), resonance ejection, and infrared ion spectroscopy (IRIS). CID and resonance ejection experiments were conducted using a Bruker Daltonics (Bremen, Gemany) SolariX XR fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. IRIS spectra of protonated TODGA and its two CID fragmentation products were measured using a modified Bruker amaZon Speed ETD 3D quadrupole ion trap mass spectrometer coupled to the Free Electron Lasers for Infrared eXperiments (FELIX) free electron laser. Measured spectra were compared with density functional theory (DFT) calculations using the Gaussian 16, Revision C.02 software package with the ?B97X-D functional and def2-TZVPP basis sets. Candidate structures were generated using the CREST 3.0 conformational sampling software tool. Preliminary Data (300 words): Collision-induced dissociation of protonated TODGA ([C36H73N2O3]+, m/z=581.562) results two fragment ions, one at m/z=340.285 assigned as [C20H38NO3]+ and the other at m/z=312.290, assigned as [C19H38NO2]+. Based on the assigned formula and the structure of protonated TODGA, the fragment at m/z=340.285 is likely formed from elimination of neutral dioctylamine. Comparison of the IRIS spectrum of m/z=340.285 with DFT predictions suggests it contains a ring structure, and is assigned as N-octyl-N-(6-oxo-1,4-dioxan-2-ylidene)octan-1-aminium. Based on this structure and the structure of protonated TODGA, we hypothesize this fragment formed from elimination of neutral dioctylamine followed by a ring closure mechanism. Comparison of the IRIS spectrum of the fragment at m/z=312.290 with DFT predictions also indicated the presence of a ring structure, assigned as N-(1,3-dioxolan-4-ylidene)-N-octyloctan-1-aminium. This product could be formed from elimination of carbon monoxide from the ring of m/z=340.285 as a sequential fragmentation or formed directly from protonated TODGA via elimination of neutral N,N-dioctylformamide followed by a ring closure. Resonance ejection experiments where m/z=340 was continuously ejected from the IRC cell showed no decrease in intensity of m/z=312.290 across several collision energies, suggesting that the later, direct formation mechanism, dominates. The location of the ionizing proton in protonated TODGA is important for modeling the fragmentation mechanisms. DFT calculations suggested that the position of bands involving the coupled vibrations of the amide C—N and C=O bonds in TODGA are the most sensitive to proton location. Evaluation of the IRIS spectrum of protonated TODGA suggests that the ionizing proton is located between the two amid oxygens. This protonation location was calculated to lie approximately 30 kJ/mol lower in energy than the next lowest energy location, with the proton located solely on one of the amide oxygens. Novel aspect (20 words): Infrared ion spectroscopy combined with resonance ejection experiments and density functional theory to probe the collision-induced dissociation mechanism of tetraoctyldiglycolamide.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Transient Mixing Driven by Buoyancy Flows

Mixing driven by buoyancy-induced flows is of particular interest to microgravity processes, as the body force that governs the intensity of flow fields can be directly controlled. We consider a model experimental system to explore the dynamics of mixing which employs two miscible liquids inside a cavity separated initially by a divider. The two liquids are oriented vertically inside a rectangular cavity with constant width and height, and varying depths to span the range of a Hele-Shaw cell to a 3-[) configuration. The two miscible liquids can be sufficiently diluted and died, for example water and deuterium oxide, such that a distinct interface exists across the divider. The transient mixing characteristic of the two fluids is addressed by following the Lagrangian history of the interface for various aspect ratios in the z-plane (depth variation) as well as a range of pulling velocities of the divider. The mixing characteristics of the two fluids are quantified from measurement of the length stretch of the interface and its flow field using respectively image processing techniques and Particle Imaging Velocimetry. Scaling analysis shows that the length stretch depends on four governing parameters, namely the Grashof number (Gr), Schmidt number (Sc), aspect ratio (Ar), and Reynolds number (Re). Variation of the Schmidt number is taken into account through thermophysical property variation. Thus our problem reduces to a codimension three bifurcation in parametric space for Gr, Ar, and Re. Our experimental results show that for Gr on the order of 106 and a nominal cavity aspect ratio Ar = 0.2, the net effect of removal of the divider and the overwhelming buoyancy force causes an overturning motion which stretches and folds the interface to produce ml internal breakwave. The structure of the breakwave is similar to the ubiquitous Rayleigh-Taylor instability morphology. The breakwave is dissipated either through internal or wall collision depending on the impulsive velocity of the divider as prescribed by the Reynolds number. The decay of the collision event occurs through sloshing oscillations over a short time scale. The two fluids then become stably stratified with a diffusive band at the interface indicating local mass transport. The local bifurcation of the internal breakwave is investigated as a function of aspect ratio. Results show that for narrow cavities on the order of 2mm (Ar = 0.04) folding does not occur, the interface only stretches. As the cavity size increases folding occurs through a supercritical bifurcation. Insight into the mechanism of folding is obtained from measurement of the flow field which shows that in the neighborhood of the folding event, there exists hyperbolic points caused by multiple vortex interactions. The global length stretch of the interface as a function of time is nearly Gaussian; calculations of finite-time Liapunov exponents as well as construction of horseshoe maps indicate the likelihood of a chaotic transient.

W.M.B. Duval↗

Quantifying the effect of anode surface roughness on diagnostic x-ray spectra using Monte Carlo simulation

Purpose: The accurate prediction of x-ray spectra under typical conditions encountered in clinical x-ray examination procedures and the assessment of factors influencing them has been a long-standing goal of the diagnostic radiology and medical physics communities. In this work, the influence of anode surface roughness on diagnostic x-ray spectra is evaluated using MCNP4C-based Monte Carlo simulations. Methods: An image-based modeling method was used to create realistic models from surface-cracked anodes. An in-house computer program was written to model the geometric pattern of cracks and irregularities from digital images of focal track surface in order to define the modeled anodes into MCNP input file. To consider average roughness and mean crack depth into the models, the surface of anodes was characterized by scanning electron microscopy and surface profilometry. It was found that the average roughness (R{sub a}) in the most aged tube studied is about 50 {mu}m. The correctness of MCNP4C in simulating diagnostic x-ray spectra was thoroughly verified by calling its Gaussian energy broadening card and comparing the simulated spectra with experimentally measured ones. The assessment of anode roughness involved the comparison of simulated spectra in deteriorated anodes with those simulated in perfectly plain anodes considered as reference. From these comparisons, the variations in output intensity, half value layer (HVL), heel effect, and patient dose were studied. Results: An intensity loss of 4.5% and 16.8% was predicted for anodes aged by 5 and 50 {mu}m deep cracks (50 kVp, 6 deg. target angle, and 2.5 mm Al total filtration). The variations in HVL were not significant as the spectra were not hardened by more than 2.5%; however, the trend for this variation was to increase with roughness. By deploying several point detector tallies along the anode-cathode direction and averaging exposure over them, it was found that for a 6 deg. anode, roughened by 50 {mu}m deep cracks, the reduction in exposure is 14.9% and 13.1% for 70 and 120 kVp tube voltages, respectively. For the evaluation of patient dose, entrance skin radiation dose was calculated for typical chest x-ray examinations. It was shown that as anode roughness increases, patient entrance skin dose decreases averagely by a factor of 15%. Conclusions: It was concluded that the anode surface roughness can have a non-negligible effect on output spectra in aged x-ray imaging tubes and its impact should be carefully considered in diagnostic x-ray imaging modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components (Final Technical Report)

Metal Additive Manufacturing (AM) is a promising method for cost-efficient fabrication of complex shape structures for applications in harsh environment, such as in a nuclear reactor. However, internal defects (pores) occur in high-strength AM alloys, which are manufactured with Laser Powder Bed Fusion (LPBF) AM method. Pulsed Infrared Thermography (PIT) is an efficient nondestructive evaluation (NDE) method to examine actual structures, because this method offers one-sided non-contact measurements, and fast processing of large sample areas. However, imaging of material defects, particularly defects with sizes at microscopic level, is challenging. In this report, we benchmark the performance of several Unsupervised Learning (UL) algorithms designed to enhance imaging of microscopic defects in metals with PIT. UL aims to learn the latent principal patterns (dictionaries) in PIT data to detect defects with minimal human supervision. Performance of Independent Component Analysis (ICA), Sparse Coding (SC), Principal Component Analysis (PCA) and Exploratory Factor Analysis (EFA) was compared using F-score, UL model training time and defects reconstruction time. We obtained the average F-score of 0.75, and a highest F-score of 0.89 for the EFA algorithm. Overall, EFA outperforms other UL algorithms considered in this study. In another approach, we investigate Thermal Tomography (TT), which is a computational method for reconstruction of depth profile of internal material defects from PIT nondestructive evaluation (NDE). TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of subsurface internals defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. Performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shape imported from scanning electron microscopy (SEM) images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on TT images of elliptical defects is capable of classifying shape and orientation of irregular defects. Training the CNN on irregular defect shapes instead of on elliptical shapes would make the resulting classifications more descriptive of actual defect shapes. However, this requires a much higher volume of SEM images of material defects, which are difficult to obtain because of random occurrence of defects in LPBF. To address this challenge, we developed a generative adversarial network (GAN) to augment the existing dataset of SEM defect images. The GAN model is demonstrated to create novel yet realistic defect shapes that can be used as input for simulated PTT images to train CNN. We also investigate several approaches based on Gaussian Random Circle and Bezier Curves for constructing parametric models of irregular-shape defects.

36 MATERIALS SCIENCE↗

SU-E-T-146: Effects of Uncertainties of Radiation Sensitivity of Biological Modelling for Treatment Planning

Purpose: The aim of this study was to evaluate the distribution of uncertainty of cell survival by radiation, and assesses the usefulness of stochastic biological model applying for gaussian distribution. Methods: For single cell experiments, exponentially growing cells were harvested from the standard cell culture dishes by trypsinization, and suspended in test tubes containing 1 ml of MEM(2x10{sup 6} cells/ml). The hypoxic cultures were treated with 95% N{sub 2}−5% CO{sub 2} gas for 30 minutes. In vitro radiosensitization was also measured in EMT6/KU single cells to add radiosensitizer under hypoxic conditions. X-ray irradiation was carried out by using an Xray unit (Hitachi X-ray unit, model MBR-1505R3) with 0.5 mm Al/1.0 mm Cu filter, 150 kV, 4 Gy/min). In vitro assay, cells on the dish were irradiated with 1 Gy to 24 Gy, respectively. After irradiation, colony formation assays were performed. Variations of biological parameters were investigated at standard cell culture(n=16), hypoxic cell culture(n=45) and hypoxic cell culture(n=21) with radiosensitizers, respectively. The data were obtained by separate schedule to take account for the variation of radiation sensitivity of cell cycle. Results: At standard cell culture, hypoxic cell culture and hypoxic cell culture with radiosensitizers, median and standard deviation of alpha/beta ratio were 37.1±73.4 Gy, 9.8±23.7 Gy, 20.7±21.9 Gy, respectively. Average and standard deviation of D{sub 50} were 2.5±2.5 Gy, 6.1±2.2 Gy, 3.6±1.3 Gy, respectively. Conclusion: In this study, we have challenged to apply these uncertainties of parameters for the biological model. The variation of alpha values, beta values, D{sub 50} as well as cell culture might have highly affected by probability of cell death. Further research is in progress for precise prediction of the cell death as well as tumor control probability for treatment planning.

60 APPLIED LIFE SCIENCES↗