Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Fault Ride-Through Control Strategy for Single-Phase Virtual Synchronous Generator

This paper presents a fault ride-through control strategy for grid-tied virtual synchronous generator (VSG) under two main grid fault conditions, grid voltage sag fault and unintentional grid outage fault. Considering the overcurrent issue of VSG during the grid voltage sag fault, mechanism on overcurrent issue and the relationship among power angle, voltage amplitude, active power and reactive power are analyzed. Based on the analysis, a control strategy based on direct power angle and voltage amplitude control is proposed. Compared to the common control strategy based on additional inner current loop, the proposed VSG requires no add extra voltage or current sensors. For the grid outage fault, detailed analysis on the relationship among power angle, active power and frequency has been conducted, and it is found that the power angle is related to the output active power when the converter operates on grid-tied condition; under unintentional islanding conditions, the power angle is related to the voltage frequency. Based on the found, a detection method based on small frequency disturbance is proposed. Simulation studies on a prototype VSG system are presented to demonstrate the validity of the proposed control strategy.

Zeng, Rong↗

GMI-IPS: Python Processing Software for Aircraft Campaigns

NASA's Atmospheric Tomography Mission (ATom) seeks to understand the impact of anthropogenic air pollution on gases in the Earth's atmosphere. Four flight campaigns are being deployed on a seasonal basis to establish a continuous global-scale data set intended to improve the representation of chemically reactive gases in global atmospheric chemistry models. The Global Modeling Initiative (GMI), is creating chemical transport simulations on a global scale for each of the ATom flight campaigns. To meet the computational demands required to translate the GMI simulation data to grids associated with the flights from the ATom campaigns, the GMI ICARTT Processing Software (GMI-IPS) has been developed and is providing key functionality for data processing and analysis in this ongoing effort. The GMI-IPS is written in Python and provides computational kernels for data interpolation and visualization tasks on GMI simulation data. A key feature of the GMI-IPS, is its ability to read ICARTT files, a text-based file format for airborne instrument data, and extract the required flight information that defines regional and temporal grid parameters associated with an ATom flight. Perhaps most importantly, the GMI-IPS creates ICARTT files containing GMI simulated data, which are used in collaboration with ATom instrument teams and other modeling groups. The initial main task of the GMI-IPS is to interpolate GMI model data to the finer temporal resolution (1-10 seconds) of a given flight. The model data includes basic fields such as temperature and pressure, but the main focus of this effort is to provide species concentrations of chemical gases for ATom flights. The software, which uses parallel computation techniques for data intensive tasks, linearly interpolates each of the model fields to the time resolution of the flight. The temporally interpolated data is then saved to disk, and is used to create additional derived quantities. In order to translate the GMI model data to the spatial grid of the flight path as defined by the pressure, latitude, and longitude points at each flight time record, a weighted average is then calculated from the nearest neighbors in two dimensions (latitude, longitude). Using SciPya's Regular Grid Interpolator, interpolation functions are generated for the GMI model grid and the calculated weighted averages. The flight path points are then extracted from the ATom ICARTT instrument file, and are sent to the multi-dimensional interpolating functions to generate GMI field quantities along the spatial path of the flight. The interpolated field quantities are then written to a ICARTT data file, which is stored for further manipulation. The GMI-IPS is aware of a generic ATom ICARTT header format, containing basic information for all flight campaigns. The GMI-IPS includes logic to edit metadata for the derived field quantities, as well as modify the generic header data such as processing dates and associated instrument files. The ICARTT interpolated data is then appended to the modified header data, and the ICARTT processing is complete for the given flight and ready for collaboration. The output ICARTT data adheres to the ICARTT file format standards V1.1. The visualization component of the GMI-IPS uses Matplotlib extensively and has several functions ranging in complexity. First, it creates a model background curtain for the flight (time versus model eta levels) with the interpolated flight data superimposed on the curtain. Secondly, it creates a time-series plot of the interpolated flight data. Lastly, the visualization component creates averaged 2D model slices (longitude versus latitude) with overlaid flight track circles at key pressure levels. The GMI-IPS consists of a handful of classes and supporting functionality that have been generalized to be compatible with any ICARTT file that adheres to the base class definition. The base class represents a generic ICARTT entry, only defining a single time entry and 3D spatial positioning parameters. Other classes inherit from this base class; several classes for input ICARTT instrument files, which contain the necessary flight positioning information as a basis for data processing, as well as other classes for output ICARTT files, which contain the interpolated model data. Utility classes provide functionality for routine procedures such as: comparing field names among ICARTT files, reading ICARTT entries from a data file and storing them in data structures, and returning a reduced spatial grid based on a collection of ICARTT entries. Although the GMI-IPS is compatible with GMI model data, it can be adapted with reasonable effort for any simulation that creates Hierarchical Data Format (HDF) files. The same can be said of its adaptability to ICARTT files outside of the context of the ATom mission. The GMI-IPS contains just under 30,000 lines of code, eight classes, and a dozen drivers and utility programs. It is maintained with GIT source code management and has been used to deliver processed GMI model data for the ATom campaigns that have taken place to date.

Damon, M. R.↗

More About the Tetrahedral Unstructured Software System

TetrUSS is a comprehensive suite of computational fluid dynamics (CFD) programs that won the Software of the Year award in 1996 and has found increasing use in government, academia, and industry for solving realistic flow problems (especially in aerodynamics and aeroelastics of aircraft having complex shapes). TetrUSS includes not only programs for solving basic equations of flow but also programs that afford capabilities for efficient generation and utilization of computational grids and for graphical representation of computed flows (see figure). The 2004 version of the Tetrahedral Unstructured Software System (TetrUSS), which is one of two software systems reported in "NASA s 2004 Software of the Year," NASA Tech Briefs, Vol. 28, No. 10 (October 2004), page 18, has been improved greatly since 1996. These improvements include (1) capabilities to simulate viscous flow by solving the Navier-Stokes equations on unstructured grids, (2) portability to personal computers from diverse manufacturers, (3) advanced models of turbulence, (4) a parallel-processing version of one of the unstructured-grid Navier-Stokes-equation-solving programs, and (5) advanced programs for generating unstructured grids.

Abdol-Hamid, Khaled S.↗

Co-optimizing Generation and Transmission Expansion with Wind Power in Large-Scale Power Grids Implementation in the US Eastern Interconnection

This paper studies the generation and transmission expansion co-optimization problem with a high wind power penetration rate in the US Eastern Interconnection (EI) power grid. In this paper, the generation and transmission expansion problem for the EI system is modeled as a mixed-integer programming (MIP) problem. Our paper also analyzed a time series generation method to capture the variation and correlation of both load and wind power across regions. The obtained series can be easily introduced into the expansion planning problem and then solved through existing MIP solvers. Simulation results show that the proposed planning model and series generation method can improve the expansion result significantly through modeling more detailed information of wind and load variation among regions in the US EI system. Moreover, the improved expansion plan that combines generation and transmission will aid system planners and policy makers to maximize the social welfare in large-scale power grids.

17 WIND ENERGY↗

Formulation and computation of dynamic, interface-compatible Whitney complexes in three dimensions

A discrete De Rham complex enables compatible, structure-preserving discretizations for a broad range of partial differential equations problems. Such discretizations can correctly reproduce the physics of interface problems, provided the grid conforms to the interface. However, large deformations, complex geometries, and evolving interfaces makes generation of such grids difficult. We develop and demonstrate two formally equivalent approaches that, for a given background mesh, dynamically construct an interface-conforming discrete De Rham complex. Both approaches start by dividing cut elements into interface-conforming subelements but differ in how they build the finite element basis on these subelements. The first approach discards the existing non-conforming basis of the parent element and replaces it by a dynamic set of degrees of freedom of the same kind. The second approach defines the interface-conforming degrees of freedom on the subelements as superpositions of the basis functions of the parent element. These approaches generalize the Conformal Decomposition Finite Element Method (CDFEM) and the extended finite element method with algebraic constraints (XFEM-AC), respectively, across the De Rham complex.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prediction of unsteady loads on maneuvering delta wings using time-accurate Euler schemes

Three-dimensional steady and unsteady vortex-dominated flows around sharp-edged delta wings are considered in this paper. The problem is formulated by using the unsteady conservative Euler equations for the flow relative motion with respect to a moving frame of reference. An implicit approximately-factored finite volume scheme is used to solve the resulting equations on a three-dimensional computational grid which is generated by using a modified Joukowski transformation in cross-flow planes at the grid chord stations. The scheme is applied to a delta wing undergoing pitching oscillation around a large angle of attack. The initial conditions correspond to a steady flow around a delta wing of aspect ratio of one, freestream Mach number of 0.3 and mean angle of attack of 20.5. The steady flow results are compared with those of an explicit computational scheme and the experimental data, and they are in good agreement.

Kandil, Osama A.↗

Hardware-in-the-Loop Evaluation of Grid-Edge DER Chip Integration Into Next-Generation Smart Meters

To facilitate the implementation of distributed energy resource management systems (DERMS), we propose to insert a grid-edge distributed energy resource (DER) chip hosting a DERMS algorithm into the next generation of smart meters. This will create a pathway for the wide adoption of DERMS technology because many utilities plan to invest in advanced metering infrastructure in the near future. This will also bridge the gap between an electrical power utility and DERs behind the meter. The DER chip is designed to follow power direction signals from the DERMS coordinator while balancing its local objectives. We tested the chip using a controller- and power-hardware-in-the-loop evaluation under three scenarios that a DERMS could face in the real world. The DER chip was capable of and effective at directing four heterogeneous DERs to respond to a DERMS coordinator for grid services (e.g., voltage regulation and a virtual power plant).

distributed energy resource management system↗

Assessing the vulnerability of solar inverters to EMPs: Port testing, PCI modeling, and protection strategies

Renewable energy sources are becoming an ever-larger contributor to the power grid. These renewable energy sources depend upon the power electronic devices, specifically inverters, being essential for connecting Photovoltaic (PV) generation to the grid. However, the Electromagnetic Pulses (EMPs) caused by the high-altitude nuclear explosions can generate fast broad-band pulses with nanosecond rise time, potentially causing damage or destruction to electronic components. To assess the vulnerability of PV inverters to high-altitude EMPs, the port testing and Pulsed Current Injection (PCI) modeling schemes are proposed based on the port impedance analysis. Wide-band frequency measurements are achieved by fusing impedance results from three vector network analyzers. Then, a PCI model is used to simulate the induced response to EMP, with two typical immunity levels of EC5 and EC8 tested. Here, the experiment successfully excites the induced voltage and current under EMP, where the voltage and current can reach 1500V/40A and 8000V/150Aunder EC5 andEC8, respectively. The port vulnerability analysis results demonstrate that only some ports can survive under EC5. To defend against the impact of EMP, three protection strategies are discussed.

42 ENGINEERING↗

Extension of the Supercritical Carbon Dioxide Brayton Cycle to Low Reactor Power Operation: Investigations using the Coupled ANL Plant Dynamics Code-SAS4A/SASSYS-1 Liquid Metal Reactor Code System

Significant progress has been made on the development of a control strategy for the supercritical carbon dioxide (S-CO 2 ) Brayton cycle enabling removal of power from an autonomous load following Sodium-Cooled Fast Reactor (SFR) down to decay heat levels such that the S-CO 2 cycle can be used to cool the reactor until decay heat can be removed by the normal shutdown heat removal system or a passive decay heat removal system such as Direct Reactor Auxiliary Cooling System (DRACS) loops with DRACS in-vessel heat exchangers. This capability of the new control strategy eliminates the need for use of a separate shutdown heat removal system which might also use supercritical CO 2 . It has been found that this capability can be achieved by introducing a new control mechanism involving shaft speed control for the common shaft joining the turbine and two compressors following reduction of the load demand from the electrical grid to zero. Following disconnection of the generator from the electrical grid, heat is removed from the intermediate sodium circuit through the sodium-to-CO 2 heat exchanger, the turbine solely drives the two compressors, and heat is rejected from the cycle through the CO 2 -to-water cooler. To investigate the effectiveness of shaft speed control, calculations are carried out using the coupled Plant Dynamics Code-SAS4A/SASSYS-1 code for a linear load reduction transient for a 1000 MWt metallic-fueled SFR with autonomous load following. No deliberate motion of control rods or adjustment of sodium pump speeds is assumed to take place. It is assumed that the S-CO 2 turbomachinery shaft speed linearly decreases from 100 to 20% nominal following reduction of grid load to zero. The reactor power is calculated to autonomously decrease down to 3% nominal providing a lengthy window in time for the switchover to the normal shutdown heat removal system or for a passive decay heat removal system to become effective. However, the calculations reveal that the compressor conditions are calculated to approach surge such that the need for a surge control system for each compressor is identified. Thus, it is demonstrated that the S-CO 2 cycle can operate in the initial decay heat removal mode even with autonomous reactor control. Because external power is not needed to drive the compressors, the results show that the S-CO 2 cycle can be used for initial decay heat removal for a lengthy interval in time in the absence of any off-site electrical power. The turbine provides sufficient power to drive the compressors. Combined with autonomous reactor control, this represents a significant safety advantage of the S-CO 2 cycle by maintaining removal of the reactor power until the core decay heat falls to levels well below those for which the passive decay heat removal system is designed. The new control strategy is an alternative to a split-shaft layout involving separate power and compressor turbines which had previously been identified as a promising approach enabling heat removal from a SFR at low power levels. The current results indicate that the split-shaft configuration does not provide any significant benefits for the S-CO 2 cycle over the current single-shaft layout with shaft speed control. It has been demonstrated that when connected to the grid the single-shaft cycle can effectively follow the load over the entire range. No compressor speed variation is needed while power is delivered to the grid. When the system is disconnected from the grid, the shaft speed can be changed as effectively as it would be with the split-shaft arrangement. In the split-shaft configuration, zero generator power means disconnection of the power turbine, such that the resulting system will be almost identical to the single-shaft arrangement. Without this advantage of the split-shaft configuration, the economic benefits of the single-shaft arrangement, provided by just one turbine and lower losses at the design point, are more important to the overall cycle performance. Therefore, the single-shaft configuration shall be retained as the reference arrangement for S-CO 2 cycle power converter preconceptual designs. Improvements to the ANL Plant Dynamics Code have been carried out. The major code improvement is the introduction of a restart capability which simplifies investigation of control strategies for very long transients. Another code modification is transfer of the entire code to a new Intel Fortran complier; the execution of the code using the new compiler was verified by demonstrating that the same results are obtained as when the previous Compaq Visual Fortran compiler was used.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hardware-in-the-Loop Evaluation of Grid-Edge DER Chip Integration Into Next-Generation Smart Meters: Preprint

To facilitate the implementation of distributed energy resource management systems (DERMS), we propose to insert a grid-edge distributed energy resource (DER) chip hosting a DERMS algorithm into the next generation of smart meters. This will create a pathway for the wide adoption of DERMS technology because many utilities plan to invest in advanced metering infrastructure in the near future. This will also bridge the gap between an electrical power utility and DERs behind the meter. The DER chip is designed to follow power direction signals from the DERMS coordinator while balancing its local objectives. We tested the chip using a controller- and power-hardware-in-the-loop evaluation under three scenarios that a DERMS could face in the real world. The DER chip was capable of and effective at directing four heterogeneous DERs to respond to a DERMS coordinator for grid services (e.g., voltage regulation and a virtual power plant).

distributed energy resource management system↗

U.S. Laws and Regulations for Renewable Energy Grid Interconnections

Rapidly declining costs of wind and solar energy technologies, increasing concerns about the environmental and climate change impacts of fossil fuels, and sustained investment in renewable energy projects all point to a not-so-distant future in which renewable energy plays a pivotal role in the electric power system of the 21st century. In light of public pressures and market factors that hasten the transition towards a low-carbon system, power system planners and regulators are preparing to integrate higher levels of variable renewable generation into the grid. Updating the regulations that govern generator interconnections and operations is crucial to ensure system reliability while creating an enabling environment for renewable energy development. This report presents a chronological review of energy laws and regulations concerning grid interconnection procedures in the United States, highlighting the consequences of policies for renewable energy interconnections. Where appropriate, this report places interconnection policies and their impacts on renewable energy within the broader context of power market reform.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Best Practice for Developing Availability Guarantee Language in Photovoltaic (PV) O&M Agreements.

This document outlines the foundation for developing language that can be utilized in an Equipment Availability Guarantee, typically included in an O&M services agreement between a PV system or plant owner and an O&M services provider, or operator. Many of the current PV O&M service agreement Availability Guarantees are based on contracts used for traditional power generation, which create challenges for owners and operators due to the variable nature of grid-tied photovoltaic generating technologies. This report documents language used in early PV availability guarantees and presents best practices and equations that can be used to more openly communicate how the reliability of the PV system and plant equipment can be expressed in an availability guarantee. This work will improve the bankability of PV systems by providing greater transparency into the equipment reliability state to all parties involved in an O&M services contract.

Klise, Geoffrey Taylor↗

Sensor network based solar forecasting using a local vector autoregressive ridge framework

The significant improvements and falling costs of photovoltaic (PV) technology make solar energy a promising resource, yet the cloud induced variability of surface solar irradiance inhibits its effective use in grid-tied PV generation. Short-term irradiance forecasting, especially on the minute scale, is critically important for grid system stability and auxiliary power source management. Compared to the trending sky imaging devices, irradiance sensors are inexpensive and easy to deploy but related forecasting methods have not been well researched. The prominent challenge of applying classic time series models on a network of irradiance sensors is to address their varying spatio-temporal correlations due to local changes in cloud conditions. We propose a local vector autoregressive framework with ridge regularization to forecast irradiance without explicitly determining the wind field or cloud movement. By using local training data, our learned forecast model is adaptive to local cloud conditions and by using regularization, we overcome the risk of overfitting from the limited training data. Our systematic experimental results showed an average of 19.7% RMSE and 20.2% MAE improvement over the benchmark Persistent Model for 1-5 minute forecasts on a comprehensive 25-day dataset.

54 ENVIRONMENTAL SCIENCES↗

Value of storage with increased renewable penetration.

The problem statement for this project is: (1) Renewable energy portfolio standards - (a) high penetration of intermittent and variable renewable generation on the grid, (b) utilities constrained by NERC Control Performance Standards, (c) requires additional resources to match generation with load; and (2) mitigation of impacts with energy storage - at what level of renewable penetration does energy storage become an attractive value proposition. Use a simplified, yet robust dispatch model that: (a) incorporates New Mexico Balance Area load and wind generation data, (b) distributes the load among a suite of generators, (c) quantifies increased generation costs with increased penetration of intermittent and variable renewable generation - fuel, startup, shut down, ramping, standby, etc., (d) tracks and quantifies NERC pentalties and violations, and (e) quantifies storage costs. Dispatch model has been constructed and it: (a) accurately distributes a load among a suite of generators, (b) quantifies duty cycle metrics for each of the generators - cumulative energy production, ramping and non ramping duration, spinning reserves, number of start-ups, and shut down durations, etc., (c) quantifies energy exchanges - cumulative exchanges, duration, and number of exchanges, (d) tracks ACE violations.

25 ENERGY STORAGE↗

Navy Ratchets Up Resilience Through Agency/Utility Collaboration

The Naval Construction Battalion Center (NCBC) in Gulfport, Mississippi, and Mississippi Power Company (MPC) have integrated a 15-acre solar photovoltaic (PV) array, battery storage, and backup generation with an innovative microgrid. The Navy and utility teams are helping ensure mission readiness at NCBC while increasing renewable energy generation on the grid in MPC's service area. The NCBC/MPC resilience effort will allow the base to more effectively deploy disaster recovery activities in the event of a grid outage.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Systematic Study to Determine 5G Baseline Performance for Scientific Computing

The fifth-generation (5G) cellular networks envisions achieving higher data rates, improved connectivity, reduced latency, and better quality of service (QoS) than the fourthgeneration (4G) cellular networks. Such improved performance can be utilized to address the challenges in applications such as electricity generation in power systems. The traditional power grids responsible for electricity generation suffer from drawbacks such as life-threatening blackout crises, and energy storage proliferation as they are not robust to extreme climatic conditions. A recent study proposed the idea of extending the capabilities of advanced wireless technologies such as the current 5G to develop a robust, energy-efficient, and secure smart grids. However there are two main challenges associated with the integration of power systems and wireless technologies. First, it is imperative to understand the architecture and the enabling technologies of 5G to ensure that the performance requirements of the smart grids are met. Second, an end-to-end testbed is required to determine if the performance requirements are met by estimating the 5G characteristics such as latency, and throughput. Our proposed alleviates the aforementioned concerns in the following manner. To begin with, a systematic study of the 5G architecture including both the StandAlone (SA) and Non-Standalone (NSA) operations is presented. Furthermore, a detailed survey of the possible 5G enabling technologies is elicited. In addition to these, an end-toend testbed that can estimate the 5G characteristics is explained in detail with appropriate preliminary results.

5G, 5G Communication↗

Reduced-Order Structure-Preserving Model for Parallel-Connected Three-Phase Grid-Tied Inverters

Next-generation power networks will contain large numbers of grid-connected inverters satisfying a significant fraction of system load. Since each inverter model has a relatively large number of dynamic states, it is impractical to analyze complex system models where the full dynamics of each inverter are retained. To address this challenge, we derive a reduced-order structure-preserving model for parallel-connected grid-tied three-phase inverters. Here, each inverter in the system is assumed to have a full-bridge topology, LCL filter at the point of common coupling, and the control architecture for each inverter includes a current controller, a power controller, and a phase-locked loop for grid synchronization. We outline a structure-preserving reduced-order inverter model with lumped parameters for the setting where the parallel inverters are each designed such that the filter components and controller gains scale linearly with the power rating. By structure preserving, we mean that the reduced-order three-phase inverter model is also composed of an LCL filter, a power controller, current controller, and PLL. We show that the system of parallel inverters can be modeled exactly as one aggregated inverter unit and this equivalent model has the same number of dynamical states as any individual inverter in the system. Numerical simulations validate the reduced-order model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NREL Controllable Grid Interface for Testing MW-Scale Wind Turbine Generators (Poster)

In order to understand the behavior of wind turbines experiencing grid disturbances, it is necessary to perform a series of tests and accurate transient simulation studies. The latest edition of the IEC 61400-21 standard describes methods for such tests that include low voltage ride-through (LVRT), active power set-point control, ramp rate limitations, and reactive power capability tests. The IEC methods are being widely adopted on both national and international levels by wind turbine manufacturers, certification authorities, and utilities. On-site testing of wind turbines might be expensive and time consuming since it requires both test equipment transportation and personnel presence in sometimes remote locations for significant periods of time because such tests need to be conducted at certain wind speed and grid conditions. Changes in turbine control software or design modifications may require redoing of all tests. Significant cost and test-time reduction can be achieved if these tests are conducted in controlled laboratory environments that replicate grid disturbances and simulation of wind turbine interactions with power systems. Such testing capability does not exist in the United States today. An initiative by NREL to design and construct a 7-MVA grid simulator to operate with the existing 2.5 MW and new upcoming 5-MW dynamometer facilities will fulfill this role and bring many potential benefits to the U.S. wind industry with the ultimate goal of reducing wind energy integration costs.

17 WIND ENERGY↗