Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Growth of epitaxial orthorhombic YO{sub 1.5}-substituted HfO{sub 2} thin film

YO{sub 1.5}-substituted HfO{sub 2} thin films with various substitution amounts were grown on (100) YSZ substrates by the pulsed laser deposition method directly from the vapor phase. The epitaxial growth of film with different YO{sub 1.5} amounts was confirmed by the X-ray diffraction method. Wide-area reciprocal lattice mapping measurements were performed to clarify the crystal symmetry of films. The formed phases changed from low-symmetry monoclinic baddeleyite to high-symmetry tetragonal/cubic fluorite phases through an orthorhombic phase as the YO{sub 1.5} amount increased from 0 to 0.15. The additional annular bright-field scanning transmission electron microscopy indicates that the orthorhombic phase has polar structure. This means that the direct growth by vapor is of polar orthorhombic HfO{sub 2}-based film. Moreover, high-temperature X-ray diffraction measurements showed that the film with a YO{sub 1.5} amount of 0.07 with orthorhombic structure at room temperature only exhibited a structural phase transition to tetragonal phase above 450 °C. This temperature is much higher than the reported maximum temperature of 200 °C to obtain ferroelectricity as well as the expected temperature for real device application. The growth of epitaxial orthorhombic HfO{sub 2}-based film helps clarify the nature of ferroelectricity in HfO{sub 2}-based films (186 words/200 words)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-J-69: Iterative Deconvolution of the Initial Photon Fluence for EPID Dosimetry: A Monte Carlo Based Study

Purpose: Developing a fast and accurate calculation model to reconstruct the applied photon fluence from an external photon radiation therapy treatment based on an image recorded by an electronic portal image device (EPID). Methods: To reconstruct the initial photon fluence the 2D EPID image was corrected for scatter from the patient/phantom and EPID to generate the transmitted primary photon fluence. This was done by an iterative deconvolution using precalculated point spread functions (PSF). The transmitted primary photon fluence was then backprojected through the patient/phantom geometry considering linear attenuation to receive the initial photon fluence applied for the treatment.The calculation model was verified using Monte Carlo simulations performed with the EGSnrc code system. EPID images were produced by calculating the dose deposition in the EPID from a 6 MV photon beam irradiating a water phantom with air and bone inhomogeneities and the ICRP anthropomorphic voxel phantom. Results: The initial photon fluence was reconstructed using a single PSF and position dependent PSFs which depend on the radiological thickness of the irradiated object. Appling position dependent point spread functions the mean uncertainty of the reconstructed initial photon fluence could be reduced from 1.13 % to 0.13 %. Conclusion: This study presents a calculation model for fluence reconstruction from EPID images. The{sup Result} show a clear advantage when position dependent PSF are used for the iterative reconstruction. The basic work of a reconstruction method was established and further evaluations must be made in an experimental study.

60 APPLIED LIFE SCIENCES↗

The CNAO dose delivery system for modulated scanning ion beam radiotherapy

Purpose: This paper describes the system for the dose delivery currently used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. Methods: CNAO Foundation, Istituto Nazionale di Fisica Nucleare and University of Torino have designed, built, and commissioned a dose delivery system (DDS) to monitor and guide ion beams accelerated by a dedicated synchrotron and to distribute the dose with a full 3D scanning technique. Protons and carbon ions are provided for a wide range of energies in order to cover a sizable span of treatment depths. The target volume, segmented in several layers orthogonally to the beam direction, is irradiated by thousands of pencil beams which must be steered and held to the prescribed positions until the prescribed number of particles has been delivered. For the CNAO beam lines, these operations are performed by the DDS. The main components of this system are two independent beam monitoring detectors, called BOX1 and BOX2, interfaced with two control systems performing the tasks of real-time fast and slow control, and connected to the scanning magnets and the beam chopper. As a reaction to any condition leading to a potential hazard, a DDS interlock signal is sent to the patient interlock system which immediately stops the irradiation. The essential tasks and operations performed by the DDS are described following the data flow from the treatment planning system through the end of the treatment delivery. Results: The ability of the DDS to guarantee a safe and accurate treatment was validated during the commissioning phase by means of checks of the charge collection efficiency, gain uniformity of the chambers, and 2D dose distribution homogeneity and stability. A high level of reliability and robustness has been proven by three years of system activity needing rarely more than regular maintenance and working with 100% uptime. Four identical and independent DDS devices have been tested showing comparable performances and are presently in use on the CNAO beam lines for clinical activity. Conclusions: The dose delivery system described in this paper is one among the few worldwide existing systems to operate ion beam for modulated scanning radiotherapy. At the time of writing, it has been used to treat more than 350 patients and it has proven to guide and control the therapeutic pencil beams reaching performances well above clinical requirements. In particular, in terms of dose accuracy and stability, daily quality assurance measurements have shown dose deviations always lower than the acceptance threshold of 5% and 2.5%, respectively.

60 APPLIED LIFE SCIENCES↗

Methodological Aspects of Shielding and Activation Analyses for ITER Diagnostics Systems - Paper 125

It is expected that the diagnostics systems of the ITER tokamak will provide valuable measurement data about the first in its kind D-T fusion plasma with emission of 14 MeV neutrons. These systems must withstand the neutron and secondary photon radiation along the ITER operation. Under the neutron irradiation the ITER materials are getting radioactive and therefore an adequate shielding must be provided along all the time of ITER operation and shut-down for the reliable machine operation and for the safe personnel access to its components, such as the diagnostics ports. These are the prerequisites for the shielding and activation analysis of the ITER diagnostics systems discussed in this paper. This paper provides insight into the current tasks of neutronics support for the development of ITER diagnostics systems. The tasks themselves range from relatively straightforward ones such as Monte Carlo radiation transport calculations for shielding analyses of the diagnostics systems, to more advanced tasks of Shut-Down Dose Rate (SDDR) analyses for which the dedicated Rigorous 2-Step mesh-based (R2Smesh) and Direct 1-Step (D1S) methodologies were applied. The accuracy and precision of the ITER neutronics analysis is dependent on the methodological approaches and the implying modeling assumptions. In addition to the SDDR challenges, another distinguishing feature of fusion neutronics is a wide use of CAD-based neutronics modeling to design components of fusion devices such as ITER and DEMO. Basically, there are two possibilities of CAD geometry settings in Monte Carlo (MC) radiation transport models, either by the geometry format conversion of CAD models into the format of MC models by means of the interface programs such as McCad and MCAM or by the direct use of CAD geometry engine in MC calculations such as it was realized in the DAGMC code approach. Several conversion interfaces and the DAGMC software library have been tested on the 3D ITER model developed for the CAD-MCNP benchmark. It was concluded that the considered approaches have reached the maturity level to allow their application to real ITER design analyses.

61 RADIATION PROTECTION AND DOSIMETRY↗

Manufacturing of Sputtering Composite Targets Containing Phases of Co{sub 2}FeSi or Co{sub 2}MnSi Heusler Alloy

The paper presents a method for manufacturing mechanically strong sputtering composite targets containing the phase of the Co{sub 2}FeSi or Co{sub 2}MnSi Heusler alloy of the stoichiometric composition, which can be used for fabrication of spin electronic devices by high-frequency magnetron deposition and pulsed laser deposition of thin films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of Radiation on the Electronic Structure of MoS 2

Electrons in a semiconductor occupy states within certain energy ranges, called energy bands. The position of the Fermi level with respect to these energy bands determines the charge carrier type of the semiconductor. Molybdenum disulfide (MoS 2 ) is a two-dimensional, n-type semiconductor with potential applications in flexible electronics, transparent electronics, and optoelectronics. Electronic devices containing MoS 2 could be used in environments where radiation affects device performance. Thus, it is important to determine the impact of radiation on MoS 2 . A one-molecule-thick layer of MoS 2 (monolayer) and a two-molecule-thick layer of MoS 2 (bilayer) were placed onto different areas of a gold (Au) substrate containing 1.2-µm-deep holes. The MoS 2 was suspended over these holes but supported by the Au elsewhere on the substrate. This sample configuration was used to determine the effect of He + radiation on the electronic properties of the suspended MoS 2 and the Au-supported MoS 2 . The MoS 2 was irradiated by He+ ions in two stages. The energy bands of the MoS 2 were measured with respect to the Fermi level via photoelectron emission microscopy before irradiation and after each irradiation stage. From each measurement, the charge carrier type of the MoS 2 after the corresponding irradiation stage was determined. The Fermi levels of the suspended monolayer and bilayer decreased by ≈0.15 eV with respect to the bands during the first irradiation stage During the second irradiation stage, however, the Fermi levels didn’t change significantly. This lack of change supports the existence of a radiation threshold, above which the electronic properties of suspended MoS 2 remain the same. The Fermi levels of the supported monolayer and bilayer increased over the cumulative irradiation and didn’t show evidence of a threshold. Thus, suspended MoS 2 becomes less n-type as it is irradiated. Supported MoS 2 , however, becomes more n-type as it is irradiated. These results could inform the development of radiation tolerance standards for MoS 2 , and thus, radiation-tolerant MoS 2 -based electronics.

36 MATERIALS SCIENCE↗

RaDIATE Collaboration for Material Studies

In the recent past, major accelerator facilities have been limited in beam power not by their accelerators, but by the beam intercepting device survivability. As next-generation accelerator target facilities (High Energy Physics, Spallation Sources, …) become increasingly more powerful and intense, high power target systems face key technical challenges. Beam-intercepting devices such as beam windows and secondary particle-production targets are continuously bombarded by high-energy high-intensity pulsed proton beams to produce secondary particles. Energy deposition from the primary beam induces near instantaneous heating (thermal shock) and microstructural changes (radiation damage) in the beam-intercepting materials. Both thermal shock and radiation damage ultimately degrade the performance and lifetime of targets and have been identified as the leading cross-cutting challenges of high-power target facilities. In order to operate reliable beam-intercepting devices in the framework of energy and intensity increase for next generation accelerators, the RaDIATE collaboration (Radiation Damage In Accelerator Target Environment) managed by Fermilab, brings together existing expertise in nuclear material and accelerator targets from 20 international institutions to execute a coordinated strategy for high power targetry R&D. This collaboration is generating new and useful materials data for application within the accelerator and the fission/fusion communities. I will give an overview of the RaDIATE R&D program and the achievement in the last few years on material studies in support of High Power Targetry development, including results obtained from irradiation test, development of novel materials and the prospective towards future irradiation campaign. A highlight will be given to the results in collaboration with our colleagues from J-PARC.

Pellemoine, Frederique↗

Multijunction InGaAs thermophotovoltaic power converter

The experimental performance of a multijunction monolithic In(0.53)Ga(0. 47)As power converter under blackbody irradiation is reported. Eight InGaAs PN junctions grown epitaxially on a semi-insulating wafer were monolithically integrated in series to boost the approximately 0.4 V photovoltage per typical InGaAs junction to over 3 volts for the 1 sq cm chip. This chip was originally designed and characterized for free-space 1.3 micron laser power beaming. This is the first report of such a multijunction TPV. This is not a traditional tandem cell in which the junctions are stacked vertically. The junctions are each about 1mm long by 1 cm wide and are laterally connected across the 1 sq cm device area. This multijunction design has the potential for lower I(sup 2)R power loss since the smaller PN junction area limits the current to one-eighth that of the equivalent surface area. In essence, the current is traded for voltage to avoid the I(sup 2)R loss, analogous to the way power utilities avoid I(sup 2)P loss in high-tension power lines, by transforming the high current, low voltage generated at a power plant into a high voltage at a low current before transmitting the power over great distances.

Wojtczuk, Steven↗

EPID-guided 3D dose verification of lung SBRT

Purpose: To investigate the feasibility of utilizing tumor tracks from electronic portal imaging device (EPID) images taken during treatment to verify the delivered dose. Methods: The proposed method is based on a computation of the delivered fluence by utilizing the planned fluence and the tumor motion track for each field. A phantom study was designed to assess the feasibility of the method. The CIRS dynamic thorax phantom was utilized with a realistic soft resin tumor, modeled after a real patient tumor. The dose calculated with the proposed method was compared to direct measurements taken with 15 metal oxide semiconductor field effect transistors (MOSFETs) inserted in small fissures made in the tumor model. The phantom was irradiated with the tumor static and moved with different range of motions and setup errors. EPID images were recorded throughout all deliveries and the tumor model was tracked post-treatment with in-house developed software. The planned fluence for each field was convolved with the tumor motion tracks to obtain the delivered fluence. Utilizing the delivered fluence from each field, the delivered dose was calculated. The estimated delivered dose was compared to the dose directly measured with the MOSFETs. The feasibility of the proposed method was also demonstrated on a real lung cancer patient, treated with stereotactic body radiotherapy. Results: The calculation of delivered dose with the delivered fluence method was in good agreement with the MOSFET measurements, with average differences ranging from 0.8% to 8.3% depending on the proximity of a dose gradient. For the patient treatment, the planned and delivered dose volume histograms were compared and verified the overall good coverage of the target volume. Conclusions: The delivered fluence method was applied successfully on phantom and clinical data and its accuracy was evaluated. Verifying each treatment fraction may enable correction strategies that can be applied during the course of treatment to ensure the desired dose coverage.

60 APPLIED LIFE SCIENCES↗

Point defects in Ga 2 O 3

In the field of high-power electronics, gallium oxide (Ga 2 O 3 ) is attracting attention due to its wide band gap and ability to be doped n-type. Point defects, including vacancies, impurities, and dopants, play important roles in optimizing device performance. This tutorial discusses the fundamental properties of point defects in monoclinic β-Ga 2 O 3 and the methods employed to study them. Oxygen vacancies are deep donors that do not cause n-type conductivity but may compensate acceptors. Gallium vacancies are deep acceptors that can be partially passivated by hydrogen. Substitutional magnesium is a promising acceptor that produces semi-insulating material and also forms a complex with hydrogen. Calcium and iron also have deep acceptor levels. Iridium deep donors are introduced into crystals grown from a melt in an Ir crucible. Here, other defects are introduced by irradiation with energetic particles such as neutrons or protons. In addition to altering the electronic properties, defects give rise to UV/visible emission bands in photoluminescence and cathodoluminescence spectra.

36 MATERIALS SCIENCE↗

Effects of Spectral Error in Efficiency Measurements of GaInAs-Based Concentrator Solar Cells

This technical report documents a particular error in efficiency measurements of triple-absorber concentrator solar cells caused by incorrect spectral irradiance -- specifically, one that occurs when the irradiance from unfiltered, pulsed xenon solar simulators into the GaInAs bottom subcell is too high. For cells designed so that the light-generated photocurrents in the three subcells are nearly equal, this condition can cause a large increase in the measured fill factor, which, in turn, causes a significant artificial increase in the efficiency. The error is readily apparent when the data under concentration are compared to measurements with correctly balanced photocurrents, and manifests itself as discontinuities in plots of fill factor and efficiency versus concentration ratio. In this work, we simulate the magnitudes and effects of this error with a device-level model of two concentrator cell designs, and demonstrate how a new Spectrolab, Inc., Model 460 Tunable-High Intensity Pulsed Solar Simulator (T-HIPSS) can mitigate the error.

14 SOLAR ENERGY↗

Production and condensation of organic gases in the atmosphere of Titan

The rates and altitudes for the dissociation of atmospheric constituents on Titan are calculated for solar ultraviolet radiation, the solar wind, Saturn magnetospheric particles, the Saturn co-rotating plasma, and cosmic rays. Laboratory experiments show that a variety of simple gas phase organic molecules and more complex organic solids called tholins are produced by such irradiations of simulated Titanian atmospheres. Except for ultraviolet wavelengths longward of the methane photodissociation continuum, most dissociation events occur between about 3100 and 3600 km altitude, corresponding well to the region of EUV opacity detected by Voyager. For a wide variety of simple to moderately complex organic gases in the Titanian atmosphere, condensation occurs below the top of the main cloud deck at about 2825 km. It is proposed that such condensates, beginning with CH4 at about 2615 km, comprise the principal mass of the Titan clouds. There is a distinct tendency for the atmosphere of Titan to act as a fractional distillation device, molecules of greater complexity condensing out at higher altitudes.

Sagan, C.↗

Production and condensation of organic gases in the atmosphere of Titan

The rates and altitudes for the dissociation of atmospheric constituents on Titan are calculated for solar ultraviolet radiation, the solar wind, Saturn magnetospheric particles, the Saturn co-rotating plasma, and cosmic rays. Laboratory experiments show that a variety of simple gas phase organic molecules and more complex organic solids called tholins are produced by such irradiations of simulated Titanian atmospheres. Except for ultraviolet wavelengths longward of the methane photodissociation continuum, most dissociation events occur between about 3100 and 3600 km altitude, corresponding well to the region of EUV opacity detected by Voyager. For a wide variety of simple to moderately complex organic gases in the Titanian atmosphere, condensation occurs below the top of the main cloud deck at about 2825 km. It is proposed that such condensates, begining with CH4 at about 2615 km comprise the principal mass of the Titan clouds. There is a distinct tendency for the atmosphere of Titan to act as a fractional distillation device, molecules of greater complexity condensing out at higher altitudes.

Sagan, C.↗

SU-E-T-463: Quantification of Rotational Variation in Mouse Setup for IGRT

Purpose: New small-animal irradiators include extremely precise IGRT capabilities. However, mouse immobilization and localization remains a challenge. In particular, unlike week-to-week translational displacements, rotational changes in positioning are not easily corrected for in subject setup. Using two methods of setup, we aim to quantify week-to-week rotational variation in mice for the purpose of IGRT planning in small animal studies. Methods: Ten mice were imaged weekly using breath-hold CBCT (X-RAD 225 Cx), with the mouse positioned in a half-pipe support, providing 40 scans. A second group of two mice were positioned in a 3D printed immobilization device, which was created using a CT from a similarly shaped mouse, providing 10 scans. For each mouse, the first image was taken to be the reference image. Subsequent CT images were then rigidly registered, based on bony anatomy. Rotations in the axial (roll), sagittal (pitch), and coronal (yaw) planes were recorded and used to quantify variation in angular setup. Results: For the mice imaged in the half pipe, average magnitude of roll was found to be 5.4±4.6° (range: −12.9:18.86°), of pitch 1.6±1.3° (range: −1.4:4.7°), and of yaw 1.9±1.5° (range −5.4:1.1°). For the mice imaged in the printed setup; average magnitude of roll was found to be 0.64±0.6° (range: −2.1:1.0°), of pitch 0.6±0.4° (range: 0.0:1.3°), and of yaw 0.2±0.1° (range: 0.0:0.4°). The printed setup provided reduction in roll, pitch, and yaw by 88, 62, and 90 percent, respectively. Conclusion: For the typical setup routine, roll in mouse position is the dominant source of rotational variation. However, when a printed device was used, drastic improvements in mouse immobilization were seen. This work provides a promising foundation for mouse immobilization, required for full scale small animal IGRT. Currently, we are making improvements to allo±w the use of a similar system for MR, PET, and bioluminescence.

60 APPLIED LIFE SCIENCES↗

WE-G-BRE-09: Targeted Radiotherapy Enhancement During Accelerated Partial Breast Irradiation (ABPI) Using Controlled Release of Gold Nanoparticles (GNPs)

Purpose: Several studies have demonstrated low rates of local recurrence with brachytherapy-based accelerated partial breast irradiation (APBI). However, long-term outcomes on toxicity (e.g. telangiectasia), and cosmesis remain a major concern. The purpose of this study is to investigate the dosimetric feasibility of using targeted non-toxic radiosensitizing gold nanoparticles (GNPs) for localized dose enhancement to the planning target volume (PTV) during APBI while reducing dose to normal tissue. Methods: Two approaches for administering the GNPs were considered. In one approach, GNPs are assumed to be incorporated in a micrometer-thick polymer film on the surface of routinely used mammosite balloon applicators, for sustained controlled in-situ release, and subsequent treatment using 50-kVp Xoft devices. In case two, GNPs are administered directly into the lumpectomy cavity e.g. via injection or using fiducials coated with the GNP-loaded polymer film. Recent studies have validated the use of fiducials for reducing the PTV margin during APBI with 6 MV beams. An experimentally determined diffusion coefficient was used to determine space-time customizable distribution of GNPs for feasible in-vivo concentrations of 43 mg/g. An analytic calculational approach from previously published work was employed to estimate the dose enhancement due to GNPs (2 and 10 nm) as a function of distance up to 1 cm from lumpectomy cavity. Results: Dose enhancement due to GNP was found to be about 130% for 50-kVp x-rays, and 110% for 6-MV external beam radiotherapy, 1 cm away from the lumpectomy cavity wall. Higher customizable dose enhancement could be achieved at other distances as a function of nanoparticle size. Conclusion: Our preliminary results suggest that significant dose enhancement can be achieved to residual tumor cells targeted with GNPs during APBI with electronic brachytherapy or external beam therapy. The findings provide a useful basis for developing nanoparticle-aided APBI, with potential to significantly reduce normal tissue/skin toxicity.

60 APPLIED LIFE SCIENCES↗

Progress In Developing An In-Pile Acoustically Telemetered Sensor Infrastructure

A salient grand challenge for a number of Department of Energy programs such as Fuels Cycle Research and Development ( includes Accident Tolerant Fuel research and the Transient Reactor Test Facility Restart experiments), Light Water Sustainability, and Advanced Reactor Technologies is to enhance our fundamental understanding of fuel and materials behavior under irradiation. Robust and accurate in-pile measurements will be instrumental to develop and validate a computationally predictive multi-scale understanding of nuclear fuel and materials. This sensing technology will enable the linking of fundamental micro-structural evolution mechanisms to the macroscopic degradation of fuels and materials. The in situ sensors and measurement systems will monitor local environmental parameters as well as characterize microstructure evolution during irradiation. One of the major road blocks in developing practical robust, and cost effective in-pile sensor systems, are instrument leads. If a wireless telemetry infrastructure can be developed for in-pile use, in-core measurements would become more attractive and effective. Thus to be successful in accomplishing effective in-pile sensing and microstructure characterization an interdisciplinary measurement infrastructure needs to be developed in parallel with key sensing technology. For the discussion in this research, infrastructure is defined as systems, technology, techniques, and algorithms that may be necessary in the delivery of beneficial and robust data from in-pile devices. The architecture of a system’s infrastructure determines how well it operates and how flexible it is to meet future requirements. The limiting path for the effective deployment of the salient sensing technology will not be the sensors themselves but the infrastructure that is necessary to communicate data from in-pile to the outside world in a non-intrusive and reliable manner. This article gives a high level overview of a promising telemetry infrastructure based on acoustic wireless transmission of data that is being developed and tested by the INL, Penn State and Westinghouse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cumulative short-lived photofission product yields for nuclear forensic application

Experiments have long been carried out with linear accelerator (linac) produced bremsstrahlung X-rays to study high-energy photon-induced fission, known as “photofission”. One benefit of photofission, when compared with neutron-induced fission, is the ability to investigate fundamental physics of fission at excitation energies lower than what is possible with neutrons [1]. Absorption of an incident neutron results in a compound nucleus with an excitation energy at least equal to the neutron binding energy; thus, the lowest energy region of the fission barrier cannot be studied. Fission product yield distributions are dependent on the incident particle energy and the target nucleus mass. They are generally represented by a double-humped curve, with low and high mass “peaks” and an intermediate mass “valley”. As incident particle energy increases, the excitation energy of the nucleus increases, thereby increasing the overall yield of isotopes in the valley with respect to the two maxima or peaks of the fission product curve [3]. Photofission is most probable for incident photons around 14 MeV due to the giant dipole resonance. Induced photofission around this energy results in a fission product yield distribution that resembles 14 MeV DT neutron fission more than thermal or fast (500 keV) neutron fission. In post-detonation nuclear forensics, the peak-to-valley ratio of the fission product yield curve could be used for characterizing device type by providing an indication of the neutron energy spectrum that had induced fission (e.g., 500 keV vs. 14 MeV). The goal of this work is to improve nuclear data for isotopes of interest in nuclear forensics and special nuclear material (SNM) detection, specifically the fission product yield data via photofission experiments for the isotopes of 238U and 232Th. Photofission has been proposed as a less costly and more flexible production method for the valley isotopes that are representative of DT neutron fission product yield distributions, which would benefit nuclear forensics exercises in testing for analysis techniques. Natural uranium and thorium targets were irradiated with bremsstrahlung photons (nominal endpoint energies of 8, 14, and 20 MeV), generated via impingement of high-energy electrons on a tungsten electron-to-photon radiator. Gamma-ray spectroscopy was used to observe and identify the decay of the resulting fission products. The photofission yields of 102 fission products were measured for the set of the 238U and 232Th targets at the three bremsstrahlung X-ray endpoint energies 8, 14, and 20 MeV. These fragments included masses ranging from A=84 to A=144, with half-lives as short as 1.07 seconds.

07 ISOTOPE AND RADIATION SOURCES↗