Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

SU-F-P-37: Implementation of An End-To-End QA Test of the Radiation Therapy Imaging, Planning and Delivery Process to Identify and Correct Possible Sources of Deviation

Purpose: To implement an end-to-end QA test of the radiation therapy imaging, planning and delivery process, aimed to assess the dosimetric agreement accuracy between planned and delivered treatment, in order to identify and correct possible sources of deviation. To establish an internal standard for machine commissioning acceptance. Methods: A test involving all steps of the radiation therapy: imaging, planning and delivery process was designed. The test includes analysis of point dose and planar dose distributions agreement between TPS calculated and measured dose. An ad hoc 16 cm diameter PMMA phantom was constructed with one central and four peripheral bores that can accommodate calibrated electron density inserts. Using Varian Eclipse 10.0 and Elekta XiO 4.50 planning systems, IMRT, RapidArc and 3DCRT with hard and dynamic wedges plans were planned on the phantom and tested. An Exradin A1SL chamber is used with a Keithley 35617EBS electrometer for point dose measurements in the phantom. 2D dose distributions were acquired using MapCheck and Varian aS1000 EPID.Gamma analysis was performed for evaluation of 2D dose distribution agreement using MapCheck software and Varian Portal Dosimetry Application.Varian high energy Clinacs Trilogy, 2100C/CD, 2000CR and low energy 6X/EX where tested.TPS-CT# vs. electron density table were checked for CT-scanners used. Results: Calculated point doses were accurate to 0.127% SD: 0.93%, 0.507% SD: 0.82%, 0.246% SD: 1.39% and 0.012% SD: 0.01% for LoX-3DCRT, HiX-3DCRT, IMRT and RapidArc plans respectively. Planar doses pass gamma 3% 3mm in all cases and 2% 2mm for VMAT plans. Conclusion: Implementation of a simple and reliable quality assurance tool was accomplished. The end-to-end proved efficient, showing excellent agreement between planned and delivered dose evidencing strong consistency of the whole process from imaging through planning to delivery. This test can be used as a first step in beam model acceptance for clinical use.

60 APPLIED LIFE SCIENCES↗

TU-FG-BRB-12: Real-Time Visualization of Discrete Spot Scanning Proton Therapy Beam for Quality Assurance

Purpose: With the growing adoption of proton beam therapy there is an increasing need for effective and user-friendly tools for performing quality assurance (QA) measurements. The speed and versatility of spot-scanning proton beam (PB) therapy systems present unique challenges for traditional QA tools. To address these challenges a proof-of-concept system was developed to visualize, in real-time, the delivery of individual spots from a spot-scanning PB in order to perform QA measurements. Methods: The PB is directed toward a custom phantom with planar faces coated with a radioluminescent phosphor (Gd2O2s:Tb). As the proton beam passes through the phantom visible light is emitted from the coating and collected by a nearby CMOS camera. The images are processed to determine the locations at which the beam impinges on each face of the phantom. By so doing, the location of each beam can be determined relative to the phantom. The cameras are also used to capture images of the laser alignment system. The phantom contains x-ray fiducials so that it can be easily located with kV imagers. Using this data several quality assurance parameters can be evaluated. Results: The proof-of-concept system was able to visualize discrete PB spots with energies ranging from 70 MeV to 220 MeV. Images were obtained with integration times ranging from 20 to 0.019 milliseconds. If not limited by data transmission, this would correspond to a frame rate of 52,000 fps. Such frame rates enabled visualization of individual spots in real time. Spot locations were found to be highly correlated (R{sup 2}=0.99) with the nozzle-mounted spot position monitor indicating excellent spot positioning accuracy Conclusion: The system was shown to be capable of imaging individual spots for all clinical beam energies. Future development will focus on extending the image processing software to provide automated results for a variety of QA tests.

60 APPLIED LIFE SCIENCES↗

Fresnel diffraction imaging of surface nanostructure using coherent resonant x-ray scattering

We investigated surface nanostructures on an antiferromagnet MnBi 2 Te 4 using a novel imaging technique, direct (real)-space and real time coherent x-ray imaging (direct-CXI). This technique has provided new insights into antiferromagnetic textures, including the formation of anti-phase antiferromagnetic (AFM) domains and thermal dynamics of AFM domains and domain walls. While this method produces real-space images of AFM textures without requiring a complex imaging retrieval process, its underlying imaging mechanism has not been fully understood, limiting a deep understanding of AFM textures and the information they contain. By investigating the well-defined structural characteristics of the nanostructures fabricated on MnBi 2 Te 4 ⁠, we elucidate the imaging principle of this novel technique. We find that the observed images can be well explained by the Fresnel diffraction integral. Using a simple model from classical optics, our calculations successfully reproduce the experimentally observed images of the nanostructures. This demonstrates that direct-CXI not only provides straightforward real-space imaging but also contains phase information through its Fresnel diffraction integral.

36 MATERIALS SCIENCE↗

DeepSZ: identification of Sunyaev–Zel’dovich galaxy clusters using deep learning

Galaxy clusters identified via the Sunyaev–Zel’dovich (SZ) effect are a key ingredient in multiwavelength cluster cosmology. In this paper, we present and compare three methods of cluster identification: the standard matched filter (MF) method in SZ cluster finding, a convolutional neural networks (CNN), and a ‘combined’ identifier. We apply the methods to simulated millimeter maps for several observing frequencies for a survey similar to SPT-3G, the third-generation camera for the South Pole Telescope. The MF requires image pre-processing to remove point sources and a model for the noise, while the CNN requires very little pre-processing of images. Additionally, the CNN requires tuning of hyperparameters in the model and takes cut-out images of the sky as input, identifying the cut-out as cluster-containing or not. We compare differences in purity and completeness. The MF signal-to-noise ratio depends on both mass and redshift. Our CNN, trained for a given mass threshold, captures a different set of clusters than the MF, some with signal-to-noise-ratio below the MF detection threshold. However, the CNN tends to mis-classify cut-out whose clusters are located near the edge of the cut-out, which can be mitigated with staggered cut-out. We leverage the complementarity of the two methods, combining the scores from each method for identification. The purity and completeness are both 0.61 for MF, and 0.59 and 0.61 for CNN. The combined method yields 0.60 and 0.77, a significant increase for completeness with a modest decrease in purity. We advocate for combined methods that increase the confidence of many low signal-to-noise clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy of UTE-MRI-based patient setup for brain cancer radiation therapy

Purpose: Radiation therapy simulations solely based on MRI have advantages compared to CT-based approaches. One feature readily available from computed tomography (CT) that would need to be reproduced with MR is the ability to compute digitally reconstructed radiographs (DRRs) for comparison against on-board radiographs commonly used for patient positioning. In this study, the authors generate MR-based bone images using a single ultrashort echo time (UTE) pulse sequence and quantify their 3D and 2D image registration accuracy to CT and radiographic images for treatments in the cranium. Methods: Seven brain cancer patients were scanned at 1.5 T using a radial UTE sequence. The sequence acquired two images at two different echo times. The two images were processed using an in-house software to generate the UTE bone images. The resultant bone images were rigidly registered to simulation CT data and the registration error was determined using manually annotated landmarks as references. DRRs were created based on UTE-MRI and registered to simulated on-board images (OBIs) and actual clinical 2D oblique images from ExacTrac™. Results: UTE-MRI resulted in well visualized cranial, facial, and vertebral bones that quantitatively matched the bones in the CT images with geometric measurement errors of less than 1 mm. The registration error between DRRs generated from 3D UTE-MRI and the simulated 2D OBIs or the clinical oblique x-ray images was also less than 1 mm for all patients. Conclusions: UTE-MRI-based DRRs appear to be promising for daily patient setup of brain cancer radiotherapy with kV on-board imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

Data from: "Warming and the dependence of limber pine (Pinus flexilis) establishment on summer soil moisture within and above its current elevation range"

This data package contains data that were used for analysis in “Warming and the dependence of limber pine (Pinus flexilis) establishment on summer soil moisture within and above its current elevation range”, by Moyes et al. 2013. All data collection and field research were completed on Niwot Ridge, Colorado, USA.This data package contains nine comma-separated-values (.csv) files, one text (.txt) file, and two zipped seedling folders that were used for leaf area analysis. One zipped folder contains 468 .jpg photographs of seedlings, and the second contains 468 corresponding Image J-processed .jpg images that include silhouette leaf area values. .csv and .txt files can be opened using any compatible simple text-editor software such as TextEdit (Mac) and Notepad (Windows); .csv’s can also be opened using R and Microsoft Excel. Image files can be opened using Preview (Mac) and Photos (Windows). In addition, there are a total of 31 Microsoft Excel files: three .xlsx files, and 28 raw Li-Cor output .xls files. This data user’s guide is available in .pdf format, and can be opened using Adobe Acrobat Reader, or any other compatible file viewing software. Geospatial data showing field site locations are also included in the archive for use and reference. There are two geospatial formats in this archive: ESRI shapefiles (.shp) and keyhole markup-language (.kml) files. Both file types contain bounding box information, with the former being polygons, and the latter containing corner coordinates for each site. ESRI shapefiles can be opened using any geospatial software compatible with the file type (such as ESRI’s ArcGIS suite and QGIS), and .kml files are compatible with Google Earth and Google Maps.--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Continued changes in climate are projected to alter the geographic distributions of plant species, in part by affecting where individuals can establish from seed. We tested the hypothesis that warming promotes uphill redistribution of subalpine tree populations by reducing cold limitation at high elevation and enhancing drought stress at low elevation. We seeded limber pine (Pinus flexilis) into plots with combinations of infrared heating and water addition treatments, at sites positioned in lower subalpine forest, the treeline ecotone, and alpine tundra. In 2010, first-year seedlings were assessed for physiological performance and survival over the snow-free growing season. Seedlings emerged in midsummer, about 5–8 weeks after snowmelt. Low temperature was not observed to limit seedling photosynthesis or respiration between emergence and October, and thus experimental warming did not appear to reduce cold limitation at high elevation. Instead, gas exchange and water potential from all sites indicated a prevailing effect of summer moisture stress on photosynthesis and carbon balance. Infrared heaters raised soil growing degree days (base 5 °C, p < 0.001) and August–September mean soil temperature (p < 0.001). Despite marked differences in vegetation cover and meteorological conditions across sites, volumetric soil moisture content (θ) at 5–10 cm below 0.16 and 0.08 m^3 m^(−3) consistently corresponded with moderate and severe indications of drought stress in midday stem water potential, stomatal conductance, photosynthesis, and respiration. Seedling survival was greater in watered plots than in heated plots (p = 0.01), and negatively related to soil growing degree days and duration of exposure to θ < 0.08 m^3 m^(−3) in a stepwise linear regression model (p < 0.0001). We concluded that seasonal moisture stress and high soil surface temperature imposed a strong limitation to limber pine seedling establishment across a broad elevation gradient, including at treeline, and that these limitations are likely to be enhanced by further climate warming.--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Maintenance log:Amended file name error in Data User's Guide May 19 2022

54 ENVIRONMENTAL SCIENCES↗

Area Values from Image Dimensions (AVID) v. 3

This code processes the images collected during high throughput tensile tests to measure the area of each specimen. First, the code identifies the reference images and primary sample images from list of images collected. Then, the size of the reference in the reference images is used to determine a scale (um/pixel) value which can be used to determine the size of each sample in an image. The subsequent sample images are processed to automatically detect the sample present and then identify the size in pixels. The measurements from two different views of the sample are then combined to determine the sample area (um2).

DeJong, StephanieA.↗

Estimation of breast percent density in raw and processed full field digital mammography images via adaptive fuzzy c-means clustering and support vector machine segmentation

Purpose: The amount of fibroglandular tissue content in the breast as estimated mammographically, commonly referred to as breast percent density (PD%), is one of the most significant risk factors for developing breast cancer. Approaches to quantify breast density commonly focus on either semiautomated methods or visual assessment, both of which are highly subjective. Furthermore, most studies published to date investigating computer-aided assessment of breast PD% have been performed using digitized screen-film mammograms, while digital mammography is increasingly replacing screen-film mammography in breast cancer screening protocols. Digital mammography imaging generates two types of images for analysis, raw (i.e., 'FOR PROCESSING') and vendor postprocessed (i.e., 'FOR PRESENTATION'), of which postprocessed images are commonly used in clinical practice. Development of an algorithm which effectively estimates breast PD% in both raw and postprocessed digital mammography images would be beneficial in terms of direct clinical application and retrospective analysis. Methods: This work proposes a new algorithm for fully automated quantification of breast PD% based on adaptive multiclass fuzzy c-means (FCM) clustering and support vector machine (SVM) classification, optimized for the imaging characteristics of both raw and processed digital mammography images as well as for individual patient and image characteristics. Our algorithm first delineates the breast region within the mammogram via an automated thresholding scheme to identify background air followed by a straight line Hough transform to extract the pectoral muscle region. The algorithm then applies adaptive FCM clustering based on an optimal number of clusters derived from image properties of the specific mammogram to subdivide the breast into regions of similar gray-level intensity. Finally, a SVM classifier is trained to identify which clusters within the breast tissue are likely fibroglandular, which are then aggregated into a final dense tissue segmentation that is used to compute breast PD%. Our method is validated on a group of 81 women for whom bilateral, mediolateral oblique, raw and processed screening digital mammograms were available, and agreement is assessed with both continuous and categorical density estimates made by a trained breast-imaging radiologist. Results: Strong association between algorithm-estimated and radiologist-provided breast PD% was detected for both raw (r= 0.82, p < 0.001) and processed (r= 0.85, p < 0.001) digital mammograms on a per-breast basis. Stronger agreement was found when overall breast density was assessed on a per-woman basis for both raw (r= 0.85, p < 0.001) and processed (0.89, p < 0.001) mammograms. Strong agreement between categorical density estimates was also seen (weighted Cohen's {kappa}{>=} 0.79). Repeated measures analysis of variance demonstrated no statistically significant differences between the PD% estimates (p > 0.1) due to either presentation of the image (raw vs processed) or method of PD% assessment (radiologist vs algorithm). Conclusions: The proposed fully automated algorithm was successful in estimating breast percent density from both raw and processed digital mammographic images. Accurate assessment of a woman's breast density is critical in order for the estimate to be incorporated into risk assessment models. These results show promise for the clinical application of the algorithm in quantifying breast density in a repeatable manner, both at time of imaging as well as in retrospective studies.

60 APPLIED LIFE SCIENCES↗

Air-to-air background oriented schlieren technique

An air-to-air background-oriented Schlieren system and method for measuring and rendering visible density changes in air that cause a refractive index change by an airborne vehicle. A sensor aircraft equipped with a high-speed visible spectrum camera travels at low airspeed on a predetermined route and on a level altitude over a background having consistent contrast and sunlight reflectivity. The target aircraft, traveling on the same predetermined route but at an altitude between the sensor aircraft and the ground (background) passes beneath the sensor aircraft. The camera on the sensor aircraft captures a series of images including a reference image immediately before the target aircraft enters the image frame followed by several data images as the target aircraft passes through the image frame. The data images are processed to calculate density gradients around the target aircraft. These density gradients include shockwaves, vortices, engine exhaust, and wakes. Air density gradients cause a refractive index change in the fluid and a slight distortion in the background pattern of the data image. Image processing that compares the data image to the reference image yields the difference caused by the density gradient.

Heineck, James Thomas↗

Beam hardening and smoothing correction effects on performance of micro-ct SkyScan 1173 for imaging low contrast density materials

We have designed and fabricated phantom mimicking breast cancer composition known as a region that has low contrast density. The used compositions are a microcalcifications, fatty tissues and tumor mass by using Al{sub 2}O{sub 3}, C{sub 27}H{sub 46}O, and hard nylon materials. Besides, phantom also has a part to calculate low cost criteria /CNR (Contrast to Noise Ratio). Uniformity will be measured at water distillation medium located in a part of phantom scale contrast. Phantom will be imaged by using micro ct-sky scan 1173 high energy type, and then also can be quantified CT number to examine SkyScan 1173 performance in imaging low contrast density materials. Evaluation of CT number is done at technique configuration parameter using voltage of 30 kV, exposure 0.160 mAs, and camera resolution 560x560 pixel, the effect of image quality to reconstruction process is evaluated by varying image processing parameters in the form of beam hardening corrections with amount of 25%, 66% and100% with each smoothing level S10,S2 and S7. To obtain the better high quality image, the adjustment of beam hardening correction should be 66% and smoothing level reach maximal value at level 10.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dark Energy Survey Year 1 Results: Photometric Data Set for Cosmology

Here, we describe the creation, content, and validation of the Dark Energy Survey (DES) internal year-one cosmology data set, Y1A1 GOLD, in support of upcoming cosmological analyses. The Y1A1 GOLD data set is assembled from multiple epochs of DES imaging and consists of calibrated photometric zeropoints, object catalogs, and ancillary data products -e.g., maps of survey depth and observing conditions, star-galaxy classification, and photometric redshift estimates|that are necessary for accurate cosmological analyses. The Y1A1 GOLD wide-area object catalog consists of 137 million objects detected in coadded images covering 1800 deg 2 in the DES grizY filters. The 10 limiting magnitude for galaxies is g = 23.4, r = 23.2, i = 22.5, z = 21.8, and Y = 20.1. We also performed photometric calibration of Y1A1 GOLD by combining nightly zeropoint solutions with stellar-locus regression, and the absolute calibration accuracy is better than 2% over the survey area. DES Y1A1 GOLD is the largest photometric data set at the achieved depth to date, enabling precise measurements of cosmic acceleration at z ≲1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of energy window for {sup 90}Y bremsstrahlung SPECT imaging for detection tasks using the ideal observer with model-mismatch

Purpose: In yttrium-90 ({sup 90}Y) microsphere brachytherapy (radioembolization) of unresectable liver cancer, posttherapy {sup 90}Y bremsstrahlung single photon emission computed tomography (SPECT) has been used to document the distribution of microspheres in the patient and to help predict potential side effects. The energy window used during projection acquisition can have a significant effect on image quality. Thus, using an optimal energy window is desirable. However, there has been great variability in the choice of energy window due to the continuous and broad energy distribution of {sup 90}Y bremsstrahlung photons. The area under the receiver operating characteristic curve (AUC) for the ideal observer (IO) is a widely used figure of merit (FOM) for optimizing the imaging system for detection tasks. The IO implicitly assumes a perfect model of the image formation process. However, for {sup 90}Y bremsstrahlung SPECT there can be substantial model-mismatch (i.e., difference between the actual image formation process and the model of it assumed in reconstruction), and the amount of the model-mismatch depends on the energy window. It is thus important to account for the degradation of the observer performance due to model-mismatch in the optimization of the energy window. The purpose of this paper is to optimize the energy window for {sup 90}Y bremsstrahlung SPECT for a detection task while taking into account the effects of the model-mismatch. Methods: An observer, termed the ideal observer with model-mismatch (IO-MM), has been proposed previously to account for the effects of the model-mismatch on IO performance. In this work, the AUC for the IO-MM was used as the FOM for the optimization. To provide a clinically realistic object model and imaging simulation, the authors used a background-known-statistically and signal-known-statistically task. The background was modeled as multiple compartments in the liver with activity parameters independently following a Gaussian distribution; the signal was modeled as a tumor with a Gaussian-distributed activity parameter located randomly with equal probability at one of three positions. The IO test statistics (i.e., likelihood ratios) were estimated using Markov-chain Monte Carlo methods. The authors realistically modeled human anatomy using a digital phantom code, and realistically simulated {sup 90}Y bremsstrahlung SPECT imaging with a clinical SPECT system and typical imaging parameters using a previously validated Monte Carlo bremsstrahlung simulation method. Model-mismatch was included by modeling image formation process in the calculation of IO test statistics using an analytic modeling method previously developed for quantitative {sup 90}Y bremsstrahlung SPECT. To demonstrate the effects of the model-mismatch on the detection task, the authors optimized the energy window both with and without model-mismatch included in the IO. Results: For all the energy windows, the AUC values for the IO-MM were smaller than that for the IO. The optimal windows for the IO-MM and the IO were 80-180 and 60-400 keV, respectively. Conclusions: The authors have demonstrated the degradation of the ideal performance due to model-mismatch and optimized the energy window for {sup 90}Y bremsstrahlung SPECT for detection tasks by accounting for the effects of the model-mismatch. The obtained optimal window was much narrower when taking into account the model-mismatch and similar to that obtained previously for estimation tasks.

61 RADIATION PROTECTION AND DOSIMETRY↗