Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOS ALAMOS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Parallel Programming in MCNP6

Monte Carlo N-Particle (MCNP)1 is a general-purpose Monte Carlo particle transport code developed by Los Alamos National Laboratory (LANL). To efficiently handle long simulations, MCNP version 6 (MCNP6) supports parallel execution using two primary programming models: • Shared-memory task-based threading using OpenMP (Open Multi-Processing), and • Distributed-memory calculations using MPI (Message Passing Interface). The OpenMP and MPI programming models enable MCNP6 to scale from desktop systems to high-performance computing (HPC) clusters, allowing users to run MCNP in one of three parallel modes: • OpenMP-only, • MPI-only, and • Hybrid (MPI + OpenMP). The choice of parallelization mode depends on the underlying computer architecture and the characteristics of the simulation problem.

97 MATHEMATICS AND COMPUTING↗

Fall SULI Report

This fall, I interned under Fan Guo and Xiaocan Li in T-2 at Los Alamos National Laboratory through the SULI program. I investigated how shock thickness is impacted by collisions between particles in plasmas and how particle acceleration in shocks is impacted by the mass ratio for protons and electrons used in simulations. Both investigations were carried out using the VPIC simulation code. I found that collisions do not meaningfully impact shock width and that higher mass ratios lead to somewhat more electron acceleration in shocks. This write-up is in three parts, the first discussing a description of what I was up to personally throughout the fall, the second discussing the results of the collisional shock study, and the third discussing the results of the high mass ratio shock study.

79 ASTRONOMY AND ASTROPHYSICS↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

Microtron Data Log

The Microtron at Los Alamos National Laboratory (LANL) is a versatile electron accelerator originally designed for medical therapy. Since 2001, it has been used for non-destructive radiographic imaging and research and development applications. Operating at four different energy levels—6, 10, 15, and 20 MeV—the Microtron produces dose rates of approximately 780, 1800, 2700, and 2800 R/min at a distance of one meter from the source, respectively. This high-energy X-ray source enables detailed internal examination of dense and thick objects without causing damage, making it invaluable for various scientific and industrial applications. For instance, LANL’s Microtron has been utilized to study the performance of large-panel cerium-doped lutetium yttrium silicon oxide (LYSO) scintillators, which are essential components in advanced imaging systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Cease Fire CFP 640 for Use in Gloveboxes (Final Report)

A Los Alamos National Laboratory (LANL) task group was established to discuss and evaluate a candidate fire suppression system (FSS) for gloveboxes (GB) and dropboxes (DB, for brevity, this report will simply refer to gloveboxes). Suitability criteria include compliance, compatibility, and capability. LANL contracted with New Mexico Tech (NMT) to quantitatively evaluate the perfor mance of one of those systems including its ability to extinguish GB fires, limit over-pressurization of the GB, etc. Additionally, the results of these experiments provide data points that could be used when fire hazard evaluations (FHEs) are conducted for determining when to require a fire suppres sion system installation within a GB (as required by NFPA 801, Standard for Facilities Handling Radioactive Materials, DOE Standard 1066-2012 Fire Protection, and AGS-G010-2011 Standard of Practice for Glovebox Fire Protection).

42 ENGINEERING↗

FRAM Version 7.1’s Bias

The Fixed-Energy Response-Function Analysis with Multiple Efficiency (FRAM) code was developed at Los Alamos National Laboratory to measure the gamma-ray spectrometry of the isotopic composition of plutonium, uranium, and other actinides. For FRAM versions 4 and earlier, the reported uncertainties of the results come from the propagation of the statistics in the peak areas only. No systematic error components are included in the reported uncertainties. For FRAM versions 5 and 6, we examined the FRAM analytical results of both the archival plutonium data and the data specifically acquired for the isotopic uncertainty analysis project and found the relationship between the bias and other parameters. We worked out the equations representing the biases of the measured isotopes from each measurement using internal spectral parameters, such as peak resolution and shape, region of analysis, and burnup (for plutonium) or enrichment (for uranium). The resulting biases were included in the reported uncertainties of FRAM v.5 and v.6.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Theoretical Modeling of Reactor Relevant Conditions for Plasma Jet Driven Magneto-Inertial Fusion

The Charger Advanced Power and Propulsion Laboratory (CAPP), a laboratory within the Propulsion Research Center (PRC) at the University of Alabama in Huntsville (UAH) is working with Los Alamos National Laboratory (LANL). to develop models and inform on promising paths for high gain magneto-inertial fusion (MIF) conditions. This report provides a framework for identifying promising conditions for achieving ignition in plasma-jet-driven magneto-inertial fusion (PJMIF)[1]. As proposed, for the first part of the contract, UAH proposes to develop a gain over unity set of stagnation conditions to provide a state of plasma conditions to achieve to set long terms goals for the PJMIF program. Specifically, UAH will model PJMIF stagnation conditions to include radiation, heat transfer, two temperature energy equations, fusion reactivity and nonlocal fusion product deposition, but no hydrodynamics for these purposes. These calculations will use a stationary plasma model to reduce simulation complexity—focusing on a DT target at 10 keV. Subsequent work will include a DD plasma layer acting as an afterburner. UAH will assume an initial magnetic field without any consideration of the topology, just assume a field strength, most likely scaled with consideration of the local hall parameter. This effort will inform the team on the tradeoff between mass, peak target field, etc and the achievable gain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry to Enable Increased Renewable Carbon Content in Transportation Fuels (CRADA 525)

Stable isotope ratio measurements of carbon atoms using isotope ratio mass spectrometry (IRMS) can be an effective tool for quantifying biogenic carbon in co-processed fuels, with results approaching the precision and accuracy of accelerator mass spectrometry (AMS). The lower cost of an IRMS may enable deployment to refineries, improving access and analysis turnaround times (≤2 hours), and, by extension, provide data that can allow process optimization to maximize renewable carbon in desired refinery products. This project explored the integration of chemical separation with IRMS analyses to enable highly detailed tracking of biogenic carbon into fuel product streams separated by boiling point range, chemical class, or specific compound. Forty-nine fuels and fuel components of fossil and biogenic origin, spanning gasoline and diesel boiling point ranges, were received from three refiners and were analyzed for their δ 13 C values via IRMS. Results spanned a 13 C range from ca. 10‰ to 44‰ and reflect materials derived from sustainable sources (e.g., C4 or C3 plants, animal-based pathways, syngas) or from fossil-derived fuels. Common ranges are approximately 18‰ to 9‰ and approximately 30‰ to 20‰ for C4 and C3 plants, respectively, and approximately 34‰ to 24‰ and approximately 70‰ to 33‰ for petroleum-derived fuels and methane, respectively. Fuel-like standards were developed and tested using direct-injection elemental analyzer (EA) IRMS for liquid fuels. This method was compared with the published methods, yielding statistically similar results. Four blend curve sets were produced ranging from 0% to 100% of a fuel containing biogenic carbon, focusing on 0% to 10% biogenic carbon. Linear fits were the most applicable for two of the four blend curve sets; however, two sets were found to exhibit slightly quadratic behavior, which was more pronounced in low biogenic blend samples, necessitating second-order fits. The origin of the slight quadratic behavior remains unclear; however, the discussion points to possible interpretations. CanmetENERGY thoroughly characterized a majority of the samples using one- and two-dimensional gas chromatography (GC and GC×GC, respectively) and other analyses. Selected samples were subjected to solid phase extraction (SPE) for saturate, olefin, aromatic, and polar (SOAP) analysis, and the resulting solvent-diluted fractions containing saturates and aromatics were returned to Pacific Northwest National Laboratory (PNNL), where the solvent was removed via evaporation or physical separation using GC techniques. Characterization and separations provided an understanding of saturate and aromatic content, as well as boiling point ranges for each sample and sample fraction. Samples resulting from SPE were examined using EA-IRMS and gas chromatography combustion IRMS (GC-C-IRMS) analyses. Both approaches suggest that the range in values between end-members can be increased by selecting the paraffinic or aromatic fraction of the end-member or by selecting among individual compounds resulting from GC separation of the paraffinic fractions. Considerable work remains to put these approaches into practice and statistically validate the benefit for using a fraction or individual compound over bulk analysis of a sample. However, initial results suggest that separations provide advantages for samples having blend ratios of less than 10% biogenic blendstocks. 13 C results showed statistically similar biofuel blend results to those obtained at PNNL, although additional work is needed to obtain better reproducibility. Select samples were sent to Los Alamos National Laboratory (LANL) for IRMS measurements and Beta Analytics for AMS measurements. This work suggests that IRMS and AMS yield closely comparable results and in some circumstances, IRMS could serve as a surrogate for AMS. While additional work is needed to better resolve statistical advantages for separations and better show the comparable nature of IRMS and AMS in both the biogenic carbon analysis of bulk chemical classes, initial results from this study suggest that these should be pursued in order to proliferate this approach for quantifying biogenic carbon in transportation fuels to the refinery level, thereby potentially enabling process optimization in co-processing scenarios.

09 BIOMASS FUELS↗

TA-54 Flanged Tritium Waste Container Operations, Radioactive Air Emissions Summary Volume 1: Stack Emissions & Off-Site Dose Consequence

In September 2025, pressure mitigation operations began on the four Flanged Tritium Waste Containers (FTWCs) that had been in storage at Los Alamos National Laboratory (LANL), Technical Area (TA-) 54, Area G, Building 1028. Each FTWC was opened at TA-54 and put into a stable configuration, then containers were moved to LANL’s Weapons Engineering Tritium Facility (WETF) for further processing in preparation for shipment off-site. Over the course of 13 operational days, the project had air emissions of 123 curies of tritium (hydrogen-3). The radiological dose to the hypothetical maximally exposed individual (MEI) member of the public from these emissions was 0.012 millirem. This is well within the limits established by the Environmental Protection Agency (EPA), which allows 10 millirem per year to any member of the public. Naturally occurring background radiation in Northern New Mexico averages about 300-400 millirem per year to residents. This report is intended to briefly summarize operations that took place in September and October 2025, provide documentation of the radionuclide air emissions from these operations, and summarize the off-site dose consequence to the public that resulted from these air emissions. Informal notifications addressing these areas were made via email to the EPA and NMED throughout the project, and summaries of these data were also posted on the LANL external web site 1 for FTWC operations.

54 ENVIRONMENTAL SCIENCES↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility of an Accelerometer-Based Structural Health Monitoring System for the LANL Blast Tube

A modeling- and simulation-based study was conducted on the feasibility of implementing an accelerometer-based SHM system on the Los Alamos National Laboratory blast tube. A blast tube experiment was modeled using the Abaqus explicit finite element solver. A custom user subroutine was written to apply test-like pressure loading to the inside surface of the blast tube. The subroutine applies analytically defined pressure loads derived from tracer output taken from a Compressible Flow Computational Fluid Dynamics Solver model of the blast tube. Five unique versions of the model were created: an undamaged reference model at 65°F was used as the baseline and compared to equivalent models at 10°F and 100°F. These three models were compared to models with small damage at the reference temperature. The two types of damage considered were a radial (circumferential) crack in the main tube body and a longitudinal crack in the supports. Acceleration outputs were extracted from accelerometer bodies included in the model and were post processed using a variety of standard SHM techniques. Different potential features signaling failure were extracted and compared using statistical methods in the time and frequency domains. A method was identified that clearly shows that differences in structural response resulting from the modeled damage can be differentiated from the structural response resulting from changing environmental conditions. However, the amount of damage applied to create observable differences in the accelerometer data was so large that simpler methods of damage detection would be more cost effective in locating damage.

42 ENGINEERING↗

The Dynamic Networks Experiments: Virtual Experiments to Quantify Gains in Nuclear Explosion Monitoring

We describe an ongoing series of virtual experiments conducted collaboratively by four United States National Laboratories: Sandia National Laboratories, Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Pacific Northwest National Laboratory. These Dynamic Network Experiments (DNEs) provide an experimental framework to evaluate the potential impact of new research tools on nuclear explosion monitoring. The second DNE (DNE2), completed in 2024, exploited waveform data (seismic, infrasound, and electromagnetic) that was recorded by multi-modal sensors within and near the Nevada National Security Site and synthetic radionuclide signatures over multiple time periods. During the execution of DNE2, we processed and analyzed data through a multi-stage event processing pipeline that ingested raw data, performed quality control, detected signals, built events from these signals, located these events, and characterized the events’ source types and sizes. For each stage and over the entire event processing pipeline, we evaluated performance changes by comparing the performance of new data processing methods, models, and algorithms against a baseline. We also performed an additional execution phase to assess event processing pipeline function, speed, and efficiency against that of an expert analyst, including computational and manual efforts. Finally, we assessed the impact and effort of modern computing infrastructure on the monitoring pipeline. This paper describes key elements of the DNEs, from formulation through execution, as demonstrated in DNE2. The DNEs introduce several novel concepts to quantitatively measure the potential impact of new methods on explosion monitoring, including the collaborative design of multi-modal datasets, performance and logistical metrics, and integrated analyses.

42 ENGINEERING↗

Remeasurement of the 239 Pu(n,f)/ 235 U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber Using Vapor-deposited Targets

The NIFFTE fission Time Projection Chamber (fissionTPC) has been used to measure the 239 Pu(n,f)/ 235 U(n,f) cross-section ratio for neutron-induced fission in the range of 0.1–100 MeV, with high precision. A white neutron source was provided by the Los Alamos Neutron Science Center, where the experiment was conducted as a remeasurement to evaluate a roughly 2% discrepancy of the previous fissionTPC results with ENDF/B-VIII.0. Further, a detailed accounting of measurement uncertainties was performed, based on the fissionTPC's novel ability to provide three-dimensional reconstruction of fission-fragment ionization profiles. Current results obtained using a vapor-deposited, highly uniform 239 Pu target, in comparison to the measurement published in 2021, where a 239 Pu electroplated target was used, are presented and discussed. The remeasurement presented here is in agreement with the previous fissionTPC result within measurement uncertainties.

235U↗

M3SF-25LL010302052 - Radionuclide Interaction with Hydrothermally Altered Repository Materials

This progress report (Level 3 Milestone Number M3SF-25LL010302052) summarizes research conducted at Lawrence Livermore National Laboratory (LLNL) within the Crystalline Host Rock Properties & Processes - LLNL Number SF-25LL01030205. Observed changes in radionuclide sorption after bentonite/clay heating have implications for radionuclide diffusive transport through engineered barriers and must be considered when designing waste disposal repositories. Recent research performed at Los Alamos National Laboratory (LANL) has provided key insights regarding the hydrothermal alteration behavior of bentonite backfill in the presence of repository materials (steel, concrete, etc.). We are examining how this mineral alteration affects retardation behavior of a suite of radionuclides of interest to repository performance assessment. Sorption experiments and data analysis for 233 U were initiated in FY24 following earlier experiments performed on 243 Am, 90 Sr, 137 Cs. In FY25, we completed the 233 U study and initiated and completed a study of 237 Np sorption. Below, we summarize the results and potential impacts of hydrothermal alteration on radionuclide retardation and assess the importance of this process to radionuclide migration from a GHRDC. We also use statistical tools (i.e. PCA) to help us determine the major drivers in affecting changes in measured Kd values induced by hydrothermal alteration. These experiments also allow us to test the predictive ability of our component additivity approach to surface complexation and ion exchange. Our guiding hypothesis is that a robust surface complexation/ion exchange model and associated database can effectively predict changes in radionuclide sorption behavior resulting from the hydrothermal alteration of mineralogy in a repository near field. In November 2024 the paper “Selenium interaction with iron minerals: Quantitative comparison of sorption and coprecipitation impacts on mobility” was published in Applied Geochemistry. A short update of results to date is presented below. In FY25, we also actively supported the DITUSC project, which is part of the EURADII initiative, as associate partners. We are executing the Migration2025 conference and support associated the NEA-TDB and Thermochimie workshops that will provide critical international engagements and develop consensus and synergy in thermodynamics as it relates to supporting the US nuclear waste repository program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utah FORGE: Triaxial Direct Shear Results - February 2025

This dataset contains results from nine triaxial direct shear tests conducted by Los Alamos National Laboratory on samples from FORGE Well 16A(78)-32. The primary objectives of this work were to determine the shear strength in both intact and residual states, evaluate dilation against displacement, assess permeability in relation to displacement, time, and normal stress, understand the relationship between aperture and normal stress, and monitor the effluent chemistry as a function of time. The data includes time-series measurements of stress, displacement, permeability, and effluent chemistry, with and without experimental dilution corrections. Additional materials include profilometry data, photographic documentation of the experimental setups and apparatus, and test notes. The dataset is organized into folders corresponding to each test, containing hydromechanical data, effluent chemistry measurements, and images. The hydromechanical data consists of detailed time-series records capturing parameters such as shear force, confining pressure, permeability, and temperature. Effluent chemistry data tracks fluid composition changes over time. Also included are conference papers, presentation slides, and a summary document outlining the experiments.

15 GEOTHERMAL ENERGY↗

The Pulse

This is the June 2016 edition of the Pulse newsletter, which presents research completed by the Los Alamos Neutron Science Center.

99 GENERAL AND MISCELLANEOUS↗

Complex Functional Materials

Complex functional materials are materials comprised of multiple components or building blocks that are integrated or chemically bound together to achieve a desired function or response. Soft materials, such as polymers, as well as structural properties at the mesoscale and micro-scale that control materials function are particularly emphasized in this area of leadership. Further, complex functional materials must generally be developed to satisfy multiple criteria essential to the overall application. Thus, this area of leadership supports applications that are aligned with all three Los Alamos National Laboratory mission areas of energy security, global security, and nuclear deterrence.

36 MATERIALS SCIENCE↗

Zapping Rocks on Mars

Better understanding Mars means better understanding its geology. That’s why, sitting atop NASA’s Curiosity rover, is ChemCam, an instrument built by Los Alamos National Laboratory that shoots lasers at Martian rocks and analyzes the data. After nearly 1,500 rock zaps, ChemCam has uncovered some surprising facts about the Red Planet, including the discovery of igneous rocks. Soon, a new Los Alamos-built instrument—the SuperCam—will ride aboard the Mars 2020 rover and bring with it enhanced capabilities to unlock new secrets about the planet.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗