Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAMMALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Pregnancy and Radiation Protection

Several modalities are currently utilized for diagnosis and therapy, by appropriate application of x-rays. In diagnostic radiology, interventional radiology, radiotherapy, interventional cardiology, nuclear medicine and other specialties radiation protection of a pregnant woman as a patient, as well as a member of the operating personnel, is of outmost importance. Based on radiation risk, the termination of pregnancy is not justified if foetal doses are below 100 mGy. For foetal doses between 100 and 500 mGy, a decision is reached on a case by case basis. In Diagnostic Radiology, when a pregnant patient takes an abdomen CT, then an estimation of the foetus' dose is necessary. However, it is extremely rare for the dose to be high enough to justify an abortion. Radiographs of the chest and extremities can be done at any period of pregnancy, provided that the equipment is functioning properly. Usually, the radiation risk is lower than the risk of not undergoing a radiological examination. Radiation exposure in uterus from diagnostic radiological examinations is unlikely to result in any deleterious effect on the child, but the possibility of a radiation-induced effect can not be entirely ruled out. The effects of exposure to radiation on the foetus depend on the time of exposure, the date of conception and the absorbed dose. Finally, a pregnant worker can continue working in an x-ray department, as long as there is reasonable assurance that the foetal dose can be kept below 1 mGy during the pregnancy. Nuclear Medicine diagnostic examinations using short-lived radionuclides can be used for pregnant patient. Irradiation of the foetus results from placental transfer and distribution of radiopharmaceuticals in the foetal tissues, as well as from external irradiation from radioactivity in the mother's organ and tissues. As a rule, a pregnant patient should not undergo therapy with radionuclide, unless it is crucial for her life. In Radiotherapy, the patient, treating oncologist, other team and family members should carefully discuss for the decision of abortion. Important factors must be considered such as the stage and aggressiveness of the tumour, the location of the tumour, the stage of pregnancy, various therapies etc.

61 RADIATION PROTECTION AND DOSIMETRY↗

Salvage High-intensity Focused Ultrasound for the Recurrent Prostate Cancer after Radiotherapy

To investigate the use of minimally invasive high-intensity focused ultrasound (HIFU) as a salvage therapy in men with localized prostate cancer recurrence following external beam radiotherapy (EBRT), brachytherapy or proton therapy. A review of 20 cases treated using the Sonablate registered 500 HIFU device, between August 28, 2002 and September 1, 2009, was carried out. All men had presumed organ-confined, histologically confirmed recurrent prostate adenocarcinoma following radiation therapy. All men with presumed, organ-confined, recurrent disease following EBRT in 8 patients, brachytherapy in 7 patients or proton therapy in 5 patients treated with salvage HIFU were included. The patients were followed for a mean (range) of 16.0 (3-80) months. Biochemical disease-free survival (bDFS) rates in patients with low-intermediate and high risk groups were 86% and 50%, respectively. Side-effects included urethral stricture in 2 of the 16 patients (13%), urinary tract infection or dysuria syndrome in eight (26%), and urinary incontinence in one (6%). Recto-urethral fistula occurred in one patient (6%). Transrectal HIFU is an effective treatment for recurrence after radiotherapy especially in patients with low- and intermediate risk groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temperature Fields in Soft Tissue during LPUS Treatment: Numerical Prediction and Experiment Results

Recent research has shown that beneficial therapeutic effects in soft tissues can be induced by the low power ultrasound (LPUS). For example, increasing of cells immunity to stress (among others thermal stress) can be obtained through the enhanced heat shock proteins (Hsp) expression induced by the low intensity ultrasound. The possibility to control the Hsp expression enhancement in soft tissues in vivo stimulated by ultrasound can be the potential new therapeutic approach to the neurodegenerative diseases which utilizes the known feature of cells to increase their immunity to stresses through the Hsp expression enhancement. The controlling of the Hsp expression enhancement by adjusting of exposure level to ultrasound energy would allow to evaluate and optimize the ultrasound-mediated treatment efficiency. Ultrasonic regimes are controlled by adjusting the pulsed ultrasound waves intensity, frequency, duration, duty cycle and exposure time. Our objective was to develop the numerical model capable of predicting in space and time temperature fields induced by a circular focused transducer generating tone bursts in multilayer nonlinear attenuating media and to compare the numerically calculated results with the experimental data in vitro. The acoustic pressure field in multilayer biological media was calculated using our original numerical solver. For prediction of temperature fields the Pennes' bio-heat transfer equation was employed. Temperature field measurements in vitro were carried out in a fresh rat liver using the 15 mm diameter, 25 mm focal length and 2 MHz central frequency transducer generating tone bursts with the spatial peak temporal average acoustic intensity varied between 0.325 and 1.95 W/cm{sup 2}, duration varied from 20 to 500 cycles at the same 20% duty cycle and the exposure time varied up to 20 minutes. The measurement data were compared with numerical simulation results obtained under experimental boundary conditions. Good agreement between the theoretical and measurement results for all cases considered has verified the validity and accuracy of our numerical model. Quantitative analysis of the obtained results enabled to find how the ultrasound-induced temperature rises in the rat liver could be controlled by adjusting the source parameters and exposure time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bone Implant Interface Investigation by Synchrotron Radiation X-Ray Microfluorescence

Zinc is known to play a relevant role in growth and development; it has stimulatory effects on in vitro and in vivo bone formation and an inhibitory effect on in vitro osteoclastic bone resorption. The inorganic component of the bone tissue is nonstoichiometric apatite; changes in the composition of hidroxyapatite are subject of studies in order to improve the tissue response after implantation. The objective of this study was to investigate the effect of 0.5% zinc-containing hydroxyapatite in comparison to hydroxyapatite on osseous repair of rabbit's tibia. Cylinders (2x6 mm) of both materials were produced according to the specification of the International Organization for Standardization. Ethics Commission on Teaching and Research in Animals approved this project (HUAP-195/06). Fifteen White New Zealand rabbits were submitted to general anesthesia and two perforations (2 mm) were made in each tibia for implantation of zinc-containing hydroxyapatite cylinders (left tibia) and hydroxyapatite cylinders (right tibia). After 1, 2 and 4 weeks, the animals were killed and one fragment of each tibia with the cylinder was collected and embedded in a methacrylate-based resin and cut into slices (approx200 {mu}m thickness), parallel to the implant's long axis with a precision diamond saw for Synchrotron Radiation X-ray Microfluorescence investigation. The accomplishment of the standard procedures helped the planning, execution and the comparative analysis of the results. The chemical and physical properties of the biomaterials were modified after its implantation and the incorporation of zinc. Both materials are biocompatible and promote osteoconduction and favored bone repair.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrastructural features of masseter muscle exhibiting altered occlusal relationship - a study in a rodent model

The role of occlusion on Tempormandibular Disorders (TMD) is still unclear, mainly regarding muscular function. The aim of this study was to evaluate the occlusion highlights on masseter ultra morphology. Twenty Wistar rats were randomly divided in four groups: 10 for control group, 10 for occlusal alteration group (CCO). Rats underwent unilateral amputation of the left inferior and superior molar cusps to simulate an occlusal wear situation. The rats of control group had no occlusal wear. Half of the animals of each group was sacrificed in 14 days after the occlusal consuming and half 30 days after the occlusal consuming. The masseter muscles ipsilateral to the amputated molars were excised and processed for light microscopy, electron microscopy. The light microscopy did not show differences between the groups. The electron microscopy was able to detect a degree of intracellular damage in muscle fibers of CCO group: swollen mitochondria with disrupted cristae and cleared matrix, signs of hypercontraction of I bands and myofibril disorganization.

60 APPLIED LIFE SCIENCES↗

Direct examination of cadmium bonding in rat tissues dosed with mine wastes and cadmium-containing solutions

Direct examination by XANES and EXAFS of metal bonding in tissue can be demonstrated by examining cadmium uptake and bonding in animal tissue maintained at cryogenic temperatures. XANES at the K-edge of cadmium were collected at the Photon Factory Advanced Ring (PF-AR), NW10A beam line at KEK-Tsukuba-Japan. Rats fed with 1g mine waste containing 8-400 mg/kg cadmium per 200g body weight (b.w.) or dosed by oral gavage with either cadmium chloride solution alone (at 6 mg/kg b.w.) or in combination with other salts (As, Cu or Zn), 5 days/week for 6 weeks, had 0.1-7.5 and 8-86 mg/kg cadmium in the liver or kidney, respectively. Rats given intraperitoneally (ip) or intravenously (iv) 1-4 times with 1 mg/kg b.w. cadmium solution had 30-120 mg/kg cadmium in the liver or kidney. Tissues from rats were kept and transferred at cryogenic temperature and XANES were recorded at 20 K. The spectra for rat liver samples suggested conjugation of cadmium with glutathione or association with the sulfide bond (Cd-S) of proteins and peptides. EXAFS of rat liver fed by Cd and Zn solutions showed that Cd was clearly bound to S ligands with an inter-atomic distance of 2.54 A ring for Cd-S that was similar to cadmium sulfide with an inter-atomic distance of 2.52 A ring for Cd-S. Liver or kidney of rats fed with mine wastes did not give an edge in the XANES spectra indicating little uptake of cadmium by the animals. Longer and higher dosing regimen may be required in order to observe the same Cd-S bond in the rat tissue from mine wastes, including confirmation by EXAFS.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Animals In Synchrotrons: Overcoming Challenges For High-Resolution, Live, Small-Animal Imaging

Physiological studies in small animals can be complicated, but the complexity is increased dramatically when performing live-animal synchrotron X-ray imaging studies. Our group has extensive experience in high-resolution live-animal imaging at the Japanese SPring-8 synchrotron, primarily examining airways in two-dimensions. These experiments normally image an area of 1.8 mmx1.2 mm at a pixel resolution of 0.45 {mu}m and are performed with live, intact, anaesthetized mice.There are unique challenges in this experimental setting. Importantly, experiments must be performed in an isolated imaging hutch not specifically designed for small-animal imaging. This requires equipment adapted to remotely monitor animals, maintain their anesthesia, and deliver test substances while collecting images. The horizontal synchrotron X-ray beam has a fixed location and orientation that limits experimental flexibility. The extremely high resolution makes locating anatomical regions-of-interest slow and can result in a high radiation dose, and at this level of magnification small animal movements produce motion-artifacts that can render acquired images unusable. Here we describe our experimental techniques and how we have overcome several challenges involved in performing live mouse synchrotron imaging.Experiments have tested different mouse strains, with hairless strains minimizing overlying skin and hair artifacts. Different anesthetics have also be trialed due to the limited choices available at SPring-8. Tracheal-intubation methods have been refined and controlled-ventilation is now possible using a specialized small-animal ventilator. With appropriate animal restraint and respiratory-gating, motion-artifacts have been minimized. The animal orientation (supine vs. head-high) also appears to affect animal physiology, and can alter image quality. Our techniques and image quality at SPring-8 have dramatically improved and in the near future we plan to translate this experience to the Imaging and Medical Beamline at the Australian Synchrotron.Overcoming these challenges has permitted increasingly sophisticated imaging of animals with synchrotron X-rays, and we expect a bright future for these techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Progress in Cell Marking for Synchrotron X-ray Computed Tomography

Recently there has been an increase in research activity into finding ways of marking cells in live animals for pre-clinical trials. Development of certain drugs and other therapies crucially depend on tracking particular cells or cell types in living systems. Therefore cell marking techniques are required which will enable longitudinal studies, where individuals can be examined several times over the course of a therapy or study. The benefits of being able to study both disease and therapy progression in individuals, rather than cohorts are clear. The need for high contrast 3-D imaging, without harming or altering the biological system requires a non-invasive yet penetrating imaging technique. The technique will also have to provide an appropriate spatial and contrast resolution. X-ray computed tomography offers rapid acquisition of 3-D images and is set to become one of the principal imaging techniques in this area. Work by our group over the last few years has shown that marking cells with gold nano-particles (GNP) is an effective means of visualising marked cells in-vivo using x-ray CT. Here we report the latest results from these studies. Synchrotron X-ray CT images of brain lesions in rats taken using the SYRMEP facility at the Elettra synchrotron in 2009 have been compared with histological examination of the tissues. Some deductions are drawn about the visibility of the gold loaded cells in both light microscopy and x-ray imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Resolution X-Ray Microangiography of 4T1 Tumor in Mouse Using Synchrotron Radiation

Angiogenesis is very important in tumor growth and metastasis. But in clinic, only vessels lager than 200 {mu}m in diameter, can be observed using conventional medical imaging. Synchrotron radiation (SR) phase contrast imaging, whose spatial resolution can reach as high as 1 {mu}m, has great advantages in imaging soft tissue structures, such as blood vessels and tumor tissues. In this paper, the morphology of newly formed micro-vessels in the mouse 4T1 tumor samples was firstly studied with contrast agent. Then, the angiogenesis in nude mice tumor window model was observed without contrast agent using the SR phase contrast imaging at the beamline for X-ray imaging and biomedical applications, Shanghai Synchrotron Radiation Facility (SSRF). The images of tumors showed dense, irregular and tortuous tumor micro-vessels with the smallest size of 20-30 {mu}m in diameter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microangiography in Living Mice Using Synchrotron Radiation

Traditionally, there are no methods available to detect the fine morphologic changes of cerebrovasculature in small living animals such as rats and mice. Newly developed synchrotron radiation microangiography can achieve a fine resolution of several micrometers and had provided us with a powerful tool to study the cerebral vasculature in small animals. The purpose of this study is to identify the morphology of cerebrovasculature especially the structure of Lenticulostriate arteries (LSAs) in living mice using the synchrotron radiation source at Shanghai Synchrotron Radiation Facility (SSRF) in Shanghai, China. Adult CD-1 mice weighing 35-40 grams were anesthetized. Nonionic iodine (Omnipaque, 350 mg I /mL) was used as a contrast agent. The study was performed at the BL13W1 beam line at SSRF. The beam line was derived from a storage ring of electrons with an accelerated energy of 3.5 GeV and an average beam current of 200 mA. X-ray energy of 33.3 keV was used to produce the highest contrast image. Images were acquired every 172 ms by a x-ray camera (Photonic-Science VHR 1.38) with a resolution of 13 {mu}m/pixel. The optimal dose of contrast agent is 100 {mu}l per injection and the injecting rate is 33 {mu}l/sec. The best position for imaging is to have the mouse lay on its right or left side, with ventral side facing the X-ray source. We observed the lenticulostriate artery for the first time in living mice. Our result show that there are 4 to 5 lenticulostriate branches originating from the root of middle cerebral artery in each hemisphere. LSAs have an average diameter of 43{+-}6.8 {mu}m. There were no differences between LSAs from the left and right hemisphere (p<0.05). These results suggest that synchrotron radiation may provide a unique tool for experimental stroke research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Blood Levels of Zinc in Creole Horses Used in Sera Production

Using Neutron Activation Analysis Zn concentrations were determined in blood of horses (Creole breed). No significant difference was observed between male (0.0029{+-}.0007 gL{sup -1}) and female (0.0031{+-}.0011 gL{sup -1}) animals. These data are an important support to understand the physiological functions of Zn in blood during the process of sera production at Butantan Institute (Sao Paulo, Brazil) using horses.

60 APPLIED LIFE SCIENCES↗

Sodium Analysis in Whole Blood of Athletes Using NAA

In this investigation the sodium levels in blood were analyzed in athletes submitted to constant load exercise at treadmill (LABEX and UNICAMP) by NAA. These data were compared with the rest condition (before starting the exercise program) as well as with the sodium levels of the healthy group (control group) select from Blood Banks. The results showed alterations in sodium levels of the athletes during the exercise training, mainly increase, suggesting the necessity of its evaluation during physical activities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Environmental Levels Of 129I Present In Bovine Thyroid And Fresh Water In Argentina

Concentrations of {sup 129}I in bovine thyroid and fresh water samples coming from all over Argentina were analyzed by Accelerator Mass Spectrometry (AMS) and total iodine present in samples by Gas Chromatography (GC) and Inductive Coupled Plasma Mass Spectrometry (ICP-MS), respectively. Once we complete this study, it will be the first set of data of this kind from an extended region of the south American subcontinent.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Auger electron spectroscopy for the determination of sex and age related Ca/P ratio at different bone sites

The Ca/P ratio of normal cortical and trabecular rat bone was measured by Auger electron spectroscopy (AES). Semiquantitative analysis was carried out using ratio techniques to draw conclusions on how age, sex and bone site affect the relative composition of calcium and phosphorus. Results show that Ca/P ratio is not sex dependent; quite the opposite, bone sites exhibit variations in elemental stoichiometry where femoral sections demonstrate higher Ca/P ratio than rear and front tibias. Age-related changes are more distinct for cortical bone in comparison with the trabecular bone. The latter's Ca/P ratio remains unaffected from all the parameters under study. This study confirms that AES is able to successfully quantify bone mineral main elements when certain critical points, related to the experimental conditions, are addressed effectively.

60 APPLIED LIFE SCIENCES↗

Breast Cancer Risk Estimation Using Parenchymal Texture Analysis in Digital Breast Tomosynthesis

Mammographic parenchymal texture has been shown to correlate with genetic markers of developing breast cancer. Digital breast tomosynthesis (DBT) is a novel x-ray imaging technique in which tomographic images of the breast are reconstructed from multiple source projections acquired at different angles of the x-ray tube. Compared to digital mammography (DM), DBT eliminates breast tissue overlap, offering superior parenchymal tissue visualization. We hypothesize that texture analysis in DBT could potentially provide a better assessment of parenchymal texture and ultimately result in more accurate assessment of breast cancer risk. As a first step towards validating this hypothesis, we investigated the association between DBT parenchymal texture and breast percent density (PD), a known breast cancer risk factor, and compared it to DM. Bilateral DBT and DM images from 71 women participating in a breast cancer screening trial were analyzed. Filtered-backprojection was used to reconstruct DBT tomographic planes in 1 mm increments with 0.22 mm in-plane resolution. Corresponding DM images were acquired at 0.1 mm pixel resolution. Retroareolar regions of interest (ROIs) equivalent to 2.5 cm{sup 3} were segmented from the DBT images and corresponding 2.5 cm{sup 2} ROIs were segmented from the DM images. Breast PD was mammographically estimated using the Cumulus scale. Overall, DBT texture features demonstrated a stronger correlation than DM to PD. The Pearson correlation coefficients for DBT were r = 0.40 (p<0.001) for contrast and r = -0.52 (p<0.001) for homogeneity; the corresponding DM correlations were r = 0.26 (p = 0.002) and r = -0.33 (p<0.001). Multiple linear regression of the texture features versus breast PD also demonstrated significantly stronger associations in DBT (R{sup 2} = 0.39) compared to DM (R{sup 2} = 0.33). We attribute these observations to the superior parenchymal tissue visualization in DBT. Our study is the first to perform DBT texture analysis in a screening population of women, showing that DBT could potentially provide better breast cancer risk assessment in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association Study between Lead and Zinc Accumulation at Different Physiological Systems of Cattle by Canonical Correlation and Canonical Correspondence Analyses

Pb pollution from automobile exhausts around highways is a persistent problem in India. Pb intoxication in mammalian body is a complex phenomenon which is influence by agonistic and antagonistic interactions of several other heavy metals and micronutrients. An attempt has been made to study the association between Pb and Zn accumulation in different physiological systems of cattles (n = 200) by application of both canonical correlation and canonical correspondence analyses. Pb was estimated from plasma, liver, bone, muscle, kidney, blood and milk where as Zn was measured from all these systems except bone, blood and milk. Both statistical techniques demonstrated that there was a strong association among blood-Pb, liver-Zn, kidney-Zn and muscle-Zn. From observations, it can be assumed that Zn accumulation in cattles' muscle, liver and kidney directs Pb mobilization from those organs which in turn increases Pb pool in blood. It indicates antagonistic activity of Zn to the accumulation of Pb. Although there were some contradictions between the observations obtained from the two different statistical methods, the overall pattern of Pb accumulation in various organs as influenced by Zn were same. It is mainly due to the fact that canonical correlation is actually a special type of canonical correspondence analyses where linear relationship is followed between two groups of variables instead of Gaussian relationship.

60 APPLIED LIFE SCIENCES↗

Interpretation of the Moessbauer Spectra of the Magnetic Nanoparticles in Mouse Spleen

We have developed a stochastic model for description of relaxation effects in the system of homogeneously magnetized single-domain particles and applied the model to the analysis of Moessbauer spectra of magnetic nanoparticles (Chemicell ARA) and mouse spleen after i.v. injection into animals. We estimate that the fraction of exogenous iron in nanoparticles in the mouse spleen 3 months after injection was 0.27{+-}0.03. The spectra of the residual nanoparticles in the spleen had almost the same isomer shift but smaller mean hyperfine magnetic field values indicating decrease in the magnetic anisotropy energy (size) of the particles compared to the initial ones in the course of biodegradation. Concentration of ferritin-like iron was about three-fold higher than that in the spleen of untreated animals showing ferritin-like forms in the mouse spleen.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dosimetry of a Small-Animal Irradiation Model using a 6 MV Linear Accelerator

A custom made rat-like phantom was used to measure dose distributions using a 6 MV linear accelerator. The phantom has air cavities that simulate the lungs and cylindrical inserts that simulate the backbone. The calculated dose distributions were obtained with the BrainScan v.5.31 TPS software. For the irradiation two cases were considered: (a) near the region where the phantom has two air cavities that simulate the lungs, and (b) with an entirely uniform phantom. The treatment plan consisted of two circular cone arcs that imparted a 500 cGy dose to a simulated lesion in the backbone. We measured dose distributions using EBT2 GafChromic film and an Epson Perfection V750 scanner working in transmission mode. Vertical and horizontal profiles, isodose curves from 50 to 450 cGy, dose and distance to agreement (DTA) histograms and Gamma index were obtained to compare the dose distributions using DoseLab v4.11. As a result, these calculations show very good agreement between calculated and measured dose distribution in both cases. With a 2% 2 mm criteria 100% of the points pass the Gamma test for the uniform case, while 98.9% of the points do it for the lungs case.

62 RADIOLOGY AND NUCLEAR MEDICINE↗