Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

An Approximate Ablative Thermal Protection System Sizing Tool for Entry System Design

A computer tool to perform entry vehicle ablative thermal protection systems sizing has been developed. Two options for calculating the thermal response are incorporated into the tool. One, an industry-standard, high-fidelity ablation and thermal response program was integrated into the tool, making use of simulated trajectory data to calculate its boundary conditions at the ablating surface. Second, an approximate method that uses heat of ablation data to estimate heat shield recession during entry has been coupled to a one-dimensional finite-difference calculation that calculates the in-depth thermal response. The in-depth solution accounts for material decomposition, but does not account for pyrolysis gas energy absorption through the material. Engineering correlations are used to estimate stagnation point convective and radiative heating as a function of time. The sizing tool calculates recovery enthalpy, wall enthalpy, surface pressure, and heat transfer coefficient. Verification of this tool is performed by comparison to past thermal protection system sizings for the Mars Pathfinder and Stardust entry systems and calculations are performed for an Apollo capsule entering the atmosphere at lunar and Mars return speeds.

Dec, John A.↗

Systems and methods for processing irradiation targets through a nuclear reactor

Apparatuses and methods produce radioisotopes in instrumentation tubes of operating commercial nuclear reactors. Irradiation targets may be inserted and removed from instrumentation tubes during operation and converted to radioisotopes otherwise unavailable during operation of commercial nuclear reactors. Example apparatuses may continuously insert, remove, and store irradiation targets to be converted to useable radioisotopes or other desired materials at several different origin and termination points accessible outside an access barrier such as a containment building, drywell wall, or other access restriction preventing access to instrumentation tubes during operation of the nuclear plant.

07 ISOTOPE AND RADIATION SOURCES↗

Deep Borehole Disposal: Options, Issues and Challenges - 16250

Different versions of deep borehole disposal vary in approach and detail and the differences raise issues and create options that need to be considered in the design of any practical implementation. Among the areas for which significant options exist are the size and depth of the disposal zone; container materials and design; the method and strategy for waste package deployment; filling of the annuli around the waste packages and the final sealing of the borehole. The options for these and other areas are discussed with a focus on their advantages and disadvantages and some conclusions reached that could provide guidance for the practical application of the concept. One particularly significant point is that the integrity of the final borehole seal(s) may not be required to survive for as long as is widely believed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of three-dimension microelectrode array for bioelectric measurement using the liquidmetal-micromolding technique

A method of manufacturing three-dimension microneedle electrode arrays is presented in this paper using the micromolding technology with liquid metal at room temperature, based on the physical property of the Bi-In-Sn liquid metal alloy, being its melting point especially low. Observed under scanning electron microscopy, the needle body of the electrode chip manufactured using this method has a good consistency. Skin penetration test in-vitro indicates that the microneedle electrode can pierce the stratum corneum and cross the high-impedance layer to acquire electrical signals. Electrical impedance and polarization voltage experimental results show that the electrode chips have great electric characteristics and meet the practical application demands.

36 MATERIALS SCIENCE↗

Assessing the reliability of fast Fourier transform-based crystal plasticity simulations of a polycrystalline material near a crack tip

Crystal plasticity simulations enable a physically-based description of the micromechanical fields associated with microstructural attributes in polycrystalline materials. Fast Fourier transforms implementation of crystal plasticity (CP-FFT) in periodic unit cells offers increased computational efficiency compared to traditional finite element methods (CP-FEM). Albeit, questions may arise concerning the accuracy of the CP-FFT approach given its underlying spectral framework, specifically in regards to: potential artifacts due to violating the traction-free conditions at internal free surface within the unit cell, Gibbs phenomenon near regions with sharp changes in local mechanical properties, and representation of free surfaces under the constraints imposed by the requirement of periodicity of the unit cell. This paper presents a custom massively parallelized implementation of CP-FFT. A direct comparison of simulation results for polycrystalline deformation near a crack in a Ti55531 alloy is presented between CP-FEM and CP-FFT. The micromechanical fields and slip system level values are quantified and are similar between the two methods. Up to 10% difference in the stress fields is reported at the crack tip and this value dissipates moving away from the crack tip after 5 voxels (7 µm). In conclusion, the results point towards the reliable use of CP-FFT simulations to model polycrystalline deformation with caveats based on the treatment of the discussed artifacts.

36 MATERIALS SCIENCE↗

Development and Application of Computational/In Vitro Toxicological Methods for Chemical Hazard Risk Reduction of New Materials for Advanced Weapon Systems

The development of quantitative structure-activity relationship (QSAR) is essential for reducing the chemical hazards of new weapon systems. The current collaboration between HEST (toxicology research and testing), MLPJ (computational chemistry) and PRS (computational chemistry, new propellant synthesis) is focusing R&D efforts on basic research goals that will rapidly transition to useful products for propellant development. Computational methods are being investigated that will assist in forecasting cellular toxicological end-points. Models developed from these chemical structure-toxicity relationships are useful for the prediction of the toxicological endpoints of new related compounds. Research is focusing on the evaluation tools to be used for the discovery of such relationships and the development of models of the mechanisms of action. Combinations of computational chemistry techniques, in vitro toxicity methods, and statistical correlations, will be employed to develop and explore potential predictive relationships; results for series of molecular systems that demonstrate the viability of this approach are reported. A number of hydrazine salts have been synthesized for evaluation. Computational chemistry methods are being used to elucidate the mechanism of action of these salts. Toxicity endpoints such as viability (LDH) and changes in enzyme activity (glutahoione peroxidase and catalase) are being experimentally measured as indicators of cellular damage. Extrapolation from computational/in vitro studies to human toxicity, is the ultimate goal. The product of this program will be a predictive tool to assist in the development of new, less toxic propellants.

Frazier, John M.↗

Diffusion-weighted imaging as a part of PET/MR for small lesion detection in patients with primary abdominal and pelvic cancer, with or without TOF reconstruction technique

Objectives: To investigate the value of diffusion-weighted imaging (DWI) in detection of small lesions (≤ 10 mm) in patients with primary abdominal and pelvic cancer in hybrid PET/MR with or without time-of-flight (TOF) technique. Materials and methods: Twenty patients (11 females and 9 males, mean age 67.23 ± 12.90 years) with histologically confirmed primary abdominal and pelvic cancer underwent hybrid PET/MR examination. A total of 64 small lesions were included in this study, which were divided into two groups (≤ 10 mm and 10–30 mm). Visual scores of small lesion detection ability were rated by five-point ordinal scale. The visual scores and detectability of small lesions on TOF PET image, noTOF PET image, and DWI sequences of hybrid PET/MR examination with or without TOF technique were analyzed. Logistic regression model was established for analysis in the value of DWI in hybrid PET/MR examination with or without TOF technique in detection of the small lesions between two groups. Results: The visual evaluation revealed the small lesion (≤ 10 mm) visual scores of DWI (mean ± SD: 4.23 ± 1.41), TOF PET image (mean ± SD: 4.14 ± 0.89), and noTOF PET image (mean ± SD: 2.68 ± 1.13);.and the visual scores of small lesions (10–30 mm) on DWI (mean ± SD: 4.98 ± 0.15), TOF PET image (mean ± SD: 4.57 ± 0.59), and noTOF PET image (mean ± SD: 3.98 ± 1.05). The visual scores of all small lesions on DWI were higher than that on TOF PET data and noTOF PET data in both two groups (**P < 0.01). The missed diagnosis rates of small FDG avid lesions (≤ 10 mm) of DWI and noTOF PET image were 9.1% and 9.1%, respectively. However, the TOF PET-based clinical diagnosis detected all small lesions (≤ 30 mm). DWI was of great importance in detection of small lesions (≤ 10 mm) in the absence of TOF technique in PET/MR examination (**P < 0.01). DWI’s effect on detection of small lesions(10-30 mm) has shown no difference between PET/MR examinations with TOF and without TOF techniques (P > 0.05). Conclusion: DWI has significant value in the detection of small lesions (≤ 10 mm) in hybrid PET/MR examination without TOF technique for patients with primary abdominal and pelvic cancer. However, it had less detection benefits in the small lesions (≤ 10 mm) in hybrid PET/MR examination with TOF PET image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irinotecan Loaded in Eluting Beads: Preclinical Assessment in a Rabbit VX2 Liver Tumor Model

Purpose: The purpose of this study was to study the pharmacokinetics of irinotecan injected intravenously, intra-arterially, or loaded onto a delivery platform. Material and Methods: Fifty-four New Zealand White rabbits with VX2 liver tumor, divided in 3 groups of 17 rabbits, each received irinotecan either by intravenous (IV) route, intra-arterial hepatic (IA) route, or loaded on drug-eluting beads (DEBIRI). Animals were killed at 1, 6, and 24 h. Irinotecan and SN-38 concentrations were measured at different time points in serum, tumor, and normal liver.ResultsTwelve milligrams of irinotecan were injected IV and IA, whereas 6-16.5 mg were injected loaded onto DEBIRI. Normalized serum irinotecan reached a peak of 333 ng/ml (range 198.8-502.5) for IV, 327.1 ng/ml (range 277.1-495.6) for IA, and 189.7 ng/ml (range 111.1-261.9) for DEBIRI (P < 0.001) delivery. The area-under-the-curve value from 10 to 60 min of serum irinotecan concentration was significantly lower for DEBIRI (P = 0.0009). Tumor irinotecan levels for IV, IA, and DEBIRI (in ng/200 mg of tissue followed by ranges in parentheses) were, respectively, 23.6 (0.3-24.9), 36.5 (7.7-1914.1), and 20.2 (2.9-319) at 1 h; 4.2 (1-27.9), 99.3 (46.6-159.5), and 42.1 (11.3-189) at 6 h; and 2.7 (2.5-6.9), 18.3 (1.5-369.1), and 174.4 (3.4-5147.3) at 24 h (P = 0.02). At 24 h, tumor necrosis was 25% (10-30), 60% (40-91.25), and 95% (76.25-95) for IV, IA, and DEBIRI, respectively (P = 0.03). Conclusion: Compared with IV or IA, DEBIRI induces lower early serum levels of irinotecan, a high and prolonged intratumoral level of irinotecan, and a greater rate of tumor necrosis at 24 h. Further evaluation of the clinical benefit of DEBIRI is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of Statistical Uncertainties in Subcritical Benchmark Measurements: Part I - Theory and Simulations

Subcritical neutron noise measurements are often used to determine multiplication of a system with Special Nuclear Material. This work presents an uncertainty approach which incorporates the singles and doubles counting rates determined by the Hage-Cifarelli formalism. This is a moments-based approach which utilizes time correlations between prompt neutrons in order to assess the system multiplication. After the method is described, a validation is presented which utilizes simulated data generated using a 0-D point-kinetics Monte Carlo code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Prospective Study of Salivary Gland Function in Lymphoma Patients Receiving Head and Neck Irradiation

Purpose: To determine the radiation dose-response relationship on salivary dysfunction and quality of life (QOL) over time in patients with lymphoma receiving radiation therapy (RT) to the head and neck (H and N). Methods and Materials: We conducted a prospective study on salivary-gland function in lymphoma patients receiving RT to the H and N. Fifteen patients were enrolled on the study. Dose-volume histograms and mean doses to the salivary glands were generated. Radiation-related toxicities and H and N-specific QOL were assessed before treatment and at prespecified time points posttreatment. Factors predicting a decrement in QOL were explored using Fisher's exact test. Results: During RT, 47% of patients experienced Grade >= 2 acute toxicity of the salivary gland, mucous membrane, or both. QOL scores improved over time, but up to one third of patients continued to have persistent oral symptoms at 2 years. At 6 months, a mean dose to at least one of the parotids of > 31 Gy was significantly associated with persistent dry mouth (100% vs. 17%, p = 0.02) and sticky saliva (100% vs. 25%, p = 0.04); a mean dose of > 11 Gy to the minor salivary glands was significantly associated with persistent sticky saliva (100% vs. 25%, p = 0.04), although the difference was no longer significant at 1 year. Conclusions: Limiting the mean parotid dose to <= 31 Gy and mean minor salivary gland dose to <= 11 Gy in lymphoma patients treated to the H and N may help reduce the risk of subacute xerostomia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uniformly 15N-Labeled Recombinant Ricin A-chain as an Internal Retention Time Standard for Increased Confidence in Forensic Identification of Ricin by Untargeted Nanoflow Liquid Chromatography-Tandem Mass Spectrometry

Ricin, a toxic protein from the castor plant, is of forensic and biosecurity interest because of its high toxicity and common occurrence in crimes and attempted crimes. Qualitative methods to detect ricin are therefore needed. Untargeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) proteomics methods are well-suited because of their high speci-ficity. Specificity in LC-MS/MS comes from both the LC and MS components. However, modern untargeted proteomics methods often use nanoflow LC, which has less reproducible retention times than standard-flow LC, making it challenging to use retention time as a point of identification in a forensic assay. We address this challenge by using retention times rela-tive to a standard, namely uniformly 15N–labeled ricin A-chain produced recombinantly in a bacterial expression system. This material, added as an internal standard prior to trypsin digestion, produces a stable isotope labeled standard for every ricin tryptic peptide in the sample. We show that the MS signals for 15N and natural isotopic abundance ricin peptides are distinct, with mass shifts that correspond to the numbers of nitrogen atoms in each peptide or fragment. We also show that, as expected, labeled and unlabeled peptides coelute, with relative retention time differences of less than 0.2%.

ricin, mass spectrometry, isotope, nitrogen-15, re↗

Analysis of longitudinal thickness-shear stiffness of a monolayer filamentary composite

The longitudinal thickness-shear behavior of a rectangular cross-section prism containing circular cross-section fibers embedded in a matrix is analyzed. The problem is formulated as a Saint-Venant flexure problem modeled by a tip-loaded cantilever composite beam and solution is obtained by the boundary-point least-squares method. It is shown that the longitudinal thickness-shear modulus is much greater than the in-plane shear modulus for a monofilament composite and therefore an independent analysis is necessary to predict the longitudinal thickness-shear behavior of the composite. Numerical results are presented in graphical form for various values of fiber volume fraction and material parameters typical of modern advanced composites.

Chang, S.↗

Nonlinear probabilistic finite element models of laminated composite shells

A probabilistic finite element analysis procedure for laminated composite shells has been developed. A total Lagrangian finite element formulation, employing a degenerated 3-D laminated composite shell with the full Green-Lagrange strains and first-order shear deformable kinematics, forms the modeling foundation. The first-order second-moment technique for probabilistic finite element analysis of random fields is employed and results are presented in the form of mean and variance of the structural response. The effects of material nonlinearity are included through the use of a rate-independent anisotropic plasticity formulation with the macroscopic point of view. Both ply-level and micromechanics-level random variables can be selected, the latter by means of the Aboudi micromechanics model. A number of sample problems are solved to verify the accuracy of the procedures developed and to quantify the variability of certain material type/structure combinations. Experimental data is compared in many cases, and the Monte Carlo simulation method is used to check the probabilistic results. In general, the procedure is quite effective in modeling the mean and variance response of the linear and nonlinear behavior of laminated composite shells.

Engelstad, S. P.↗

Analysis of Radiation-natural Convection Interactions in 1-g and low-g Environments using the Discrete Exchange Factor Method

A new numerical method is presented for the analysis of combined natural convection and radiation heat transfer with applications in many engineering situations such as materials processing, combustion and fire research. Because of the recent interest in the low gravity environment of space, attention is devoted to both 1-g and low-g applications. The two-dimensional mathematical model is represented by a set of coupled nonlinear integro-partial differential equations. Radiative exchange is formulated using the Discrete Exchange Factor method (DEF). This method considers point to point exchange and provides accurate results over a wide range of radiation parameters. Numerical results show that radiation significantly influences the flow and heat transfer in both low-g and 1-g applications. In the low-g environment, convection is weak, and radiation can easily become the dominant heat transfer mode. It is also shown that volumetric heating by radiation gives rise to an intricate cell pattern in the top heated enclosure.

Kassemi, M.↗

Update on Ultrasonic Thermometry Development at Idaho National Laboratory

The Idaho National Laboratory (INL) has initiated an effort to evaluate the viability of using ultrasonic thermometry technology as an improved sensor for detecting temperature during irradiation testing of advanced fuels proposed within the Fuel Cycle Research and Development (FCR&D) program sponsored by the U.S. Department of Energy (US DOE). Ultrasonic thermometers (UTs) work on the principle that the speed at which sound travels through a material (acoustic velocity) is dependent on the temperature of the material. UTs have several advantages over other types of temperature sensors . UTs can be made very small, as the sensor consists only of a small diameter rod which may or may not require a sheath. Measurements may be made up to very high temperature (near the melting point of the sensor material) and, as no electrical insulation is required, shunting effects observed in traditional high temperature thermocouple applications are avoided. Most attractive, however, is the ability to introduce multiple acoustic discontinuities into the sensor, as this enables temperature profiling with a single sensor. The current paper presents initial results from FCR&D UT development efforts. These developments include improved methods for fabricating magnetostrictive transducers and joining them to waveguides, characterization of candidate sensor materials appropriate for use in FCR&D fuels irradiations (both ceramic fuels in inert gas and sodium bonded metallic fuels), enhanced signal processing techniques, and tests to determine potential accuracy and resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A continuum meshfree method for sandbox-style numerical modeling of accretionary and doubly vergent wedges

Here, in this study, we introduce and utilize GEOSPH, a Lagrangian particle-based continuum Smoothed Particle Hydrodynamics (SPH) code to simulate the deformation of geologic materials in sandbox-style experiments using an elastoplastic constitutive model. Due to the meshfree nature of SPH, our proposed framework is capable of handling the large deformations characteristic of sandbox-style experiments. SPH is also able to capture strain localization and discontinuities, allowing us to resolve faulting patterns emerging in the sandbox experiments. We successfully validate our SPH implementation against the benchmark experiments of Buiter and co-workers, and then apply SPH to understand the deformational processes occurring in doubly vergent orogens resultant from the S-point experimental setup and from finitely high wedge-like indenter backstops of different inclinations. We find that the topographic slope of the prowedge results from the competing processes of vertical uplift due to the indenter and forward thrusting, while the topographic slope of the retrowedge is a product of repeated shallow slope failure. Our findings show that SPH is a promising numerical method which should be added to the current palette of computational tools used by structural geologists for solving problems relating to tectonics and crustal deformation.

58 GEOSCIENCES↗

Hydrothermal synthesis and magnetic properties of nanoplate-assembled hierarchical structured Co{sub 1-x}S microrods

Hierarchical structured Co{sub 1-x}S microrods have been first fabricated in a high yield by a one-pot complex-surfactant-assisted hydrothermal method. The microrod is assembled by numerous interleaving nanoplates. X-ray diffraction, X-ray photoelectron spectroscopy, Fourier-transform infrared spectroscopy spectrum, scanning electron microscopy, and transmission electron microscopy were used to characterize the samples. The mechanism for the formation of the hierarchical microstructures has been proposed. Additionally, the magnetic characterization suggests that the obtained Co{sub 1-x}S microrods are ferromagnetic at low temperature. - Highlights: Black-Right-Pointing-Pointer Hierarchical structured Co{sub 1-x}S microrods are fabricated by hydrothermal method. Black-Right-Pointing-Pointer The microrods are assembled by numerous interleaving nanoplates. Black-Right-Pointing-Pointer The growth mechanism of rodlike microstructures is proposed. Black-Right-Pointing-Pointer The obtained Co{sub 1-x}S microrods are ferromagnetic at low temperature.

36 MATERIALS SCIENCE↗

Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data

Purpose: To provide a method for calculating the transmission of any broad photon beam with a known energy spectrum in the range of 20–1090 keV, through concrete and lead, based on the superposition of corresponding monoenergetic data obtained from Monte Carlo simulation. Methods: MCNP5 was used to calculate broad photon beam transmission data through varying thickness of lead and concrete, for monoenergetic point sources of energy in the range pertinent to brachytherapy (20–1090 keV, in 10 keV intervals). The three parameter empirical model introduced byArcher et al. [“Diagnostic x-ray shielding design based on an empirical model of photon attenuation,” Health Phys. 44, 507–517 (1983)] was used to describe the transmission curve for each of the 216 energy-material combinations. These three parameters, and hence the transmission curve, for any polyenergetic spectrum can then be obtained by superposition along the lines of Kharrati et al. [“Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities,” Med. Phys. 34, 1398–1404 (2007)]. A simple program, incorporating a graphical user interface, was developed to facilitate the superposition of monoenergetic data, the graphical and tabular display of broad photon beam transmission curves, and the calculation of material thickness required for a given transmission from these curves. Results: Polyenergetic broad photon beam transmission curves of this work, calculated from the superposition of monoenergetic data, are compared to corresponding results in the literature. A good agreement is observed with results in the literature obtained from Monte Carlo simulations for the photon spectra emitted from bare point sources of various radionuclides. Differences are observed with corresponding results in the literature for x-ray spectra at various tube potentials, mainly due to the different broad beam conditions or x-ray spectra assumed. Conclusions: The data of this work allow for the accurate calculation of structural shielding thickness, taking into account the spectral variation with shield thickness, and broad beam conditions, in a realistic geometry. The simplicity of calculations also obviates the need for the use of crude transmission data estimates such as the half and tenth value layer indices. Although this study was primarily designed for brachytherapy, results might also be useful for radiology and nuclear medicine facility design, provided broad beam conditions apply.

61 RADIATION PROTECTION AND DOSIMETRY↗