Search NASA⌕ Search

SEARCH · Search NASA

Results for “NonDestructive Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Analysis of historical delta values for IAEA/LANL NDA training courses

The Los Alamos National Laboratory (LANL) supports the International Atomic Energy Agency (IAEA) by providing training for IAEA inspectors in neutron and gamma-ray Nondestructive Assay (NDA) of nuclear material. Since 1980, all new IAEA inspectors attend this two week course at LANL gaining hands-on experience in the application of NDA techniques, procedures and analysis to measure plutonium and uranium nuclear material standards with well known pedigrees. As part of the course the inspectors conduct an inventory verification exercise. This exercise provides inspectors the opportunity to test their abilities in performing verification measurements using the various NDA techniques. For an inspector, the verification of an item is nominally based on whether the measured assay value agrees with the declared value to within three times the historical delta value. The historical delta value represents the average difference between measured and declared values from previous measurements taken on similar material with the same measurement technology. If the measurement falls outside a limit of three times the historical delta value, the declaration is not verified. This paper uses measurement data from five years of IAEA courses to calculate a historical delta for five non-destructive assay methods: Gamma-ray Enrichment, Gamma-ray Plutonium Isotopics, Passive Neutron Coincidence Counting, Active Neutron Coincidence Counting and the Neutron Coincidence Collar. These historical deltas provide information as to the precision and accuracy of these measurement techniques under realistic conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Considerations for Qualifying Reliable Eddy Current Array Technique for Detection of Backwall Cracks

A reliable nondestructive evaluation (NDE) technique provides minimum 90% probability of detection(POD) with 95% confidence for detection of cracklike flaws of a qualified size. In this case, the flaws are on backside of material. Eddy current array (ECA) probe or a single sensor eddy current probe in c-scanning mode is used for the flaw detection. Here, two geometries are considered for the test specimens. The two geometries are, a flat plate, and tube or pipe. The probe is assumed to be on outer diameter (OD)surface and the flaw is assumed to be at the inner diameter (ID) surface for tube inspection. The flaw and probe are on opposite side of wall thickness for inspection of plate material. The application may be used for acreage inspection or just for inspection of butt weld and heat affected zone (HAZ) in a tube, cylinder, or plate. The proposed approach is based on developing an instrument standardization or calibration procedure. Decision threshold of inspection procedure is determined using empirical qualification and noise data. The work explores essential parameters that are required to meet certain conditions to ensure reliable flaw detection. Physics-based simulation of eddy current array flaw detection is used to understand effect of essential parameters on signal response (amplitude and phase),and therefore flaw detectability. Simulation data is used to justify choice of calibration reference standard requirements and the qualification approach. An ECA technique qualification model is provided. The paper gives brief description of tasks to be completed for qualifying ECA technique for reliable detection of cracklike flaws.

Eddy current array inspection, nondestructive eval↗

Comparison of three measurement modalities for 3D characterization of manufactured features and process-induced porosity in titanium alloy additively manufactured parts

Nondestructive characterization of internal features and defects within complex components is vital for many industrial applications, particularly with the advent of additive manufacturing (AM) technologies. However, community understanding of the limitations of nondestructive methods such as X-ray Computed Tomography (CT) can be limited in certain industrial sectors as these may be emergent applications. In this paper, we investigate the limits of X-ray CT measurements and compare extracted data with mechanical polishing serial sectioning (MPSS) and confocal laser scanning microscopy (CLSM). The test object is an additively manufactured titanium alloy disk that contains both process-induced porosity and machined features, including focused ion beam milled features designed to probe the resolution limits of X-ray CT. Results show that each of these characterization techniques has advantages and disadvantages. We compare data acquisition times, spatial resolution, geometric measurement accuracy and defect visualization fidelity across these modalities to establish a practical framework.

Additive manufacturing↗

35-45 Giga Hertz Transceiver System for Phase and Magnitude Detection

Nondestructive evaluation (NDE) is the science and practice of examining an object in a way that the object's usefulness is not adversely affected. Different types of NDE methods exist but this thesis is based on microwave and millimeter wave NDE using imaging techniques. Microwave NDE is based on illuminating the object under test with a microwave signal and studying the various properties of the reflected signal from the object. This reflected signal contains some information about the inner structure of the object under test. This information may be contained in several parameters including the phase and magnitude of the reflected signal. The goal of this project is to design and build a Q-band coherent transceiver that is capable of measuring the reflected signal's phase and magnitude so that an image of the object under test may be reconstructed. From the several techniques that can be used to construct an image of the object under test, techniques of interest to this work include synthetic aperture focusing technique (SAFT) and microwave holography. The transceiver system should have the ability to sweep a large portion of Q-band frequency range in small frequency steps as quick as possible while the detected phase and magnitude of the reflected signal is very accurate. Several different designs were studied and the final schematic diagram of the transceiver system was determined. One of the most important modules that was designed, implemented and tested in the laboratory was an accurate phase/magnitude detector circuit. The compared results of the scans using the transceiver system and vector network analyzer (VNA) showed that this transceiver system has a great potential to replace a VNA for the purpose of microwave and millimeter wave imaging.

Beni, Aman Aflaki↗

Smart Crop Farming Systems for Artemis Exploration Missions

Space crop production systems that mitigate risks of crew poor performance or illness due to inadequate food and nutrition are needed during manned Artemis exploration missions beyond LEO. Prototype farms must be designed for deployment on ISS and tested in manned platforms: Gateway, lunar habitats, and Mars trans-hab spacecraft in preparation for human missions to Mars. Food production must be optimal and safe for human consumption. Thus, plant growth facilities (i.e. Veggie and APH) can be enhanced with imaging systems (including hyperspectral, multispectral, lidar, and fluorescence imaging systems) for nondestructive monitoring of plant health, stress and assessing food safety. Databases of crop responses to stress obtained during ground studies can be used to develop novel artificial intelligence (AI) algorithms for optimizing crop production (i.e. environmental settings during growth) and for detecting crop indices that ensure food safety. Future farming systems should be sustainable and smart. Novel adaptive AI algorithms requiring limited data sets for calibration are needed for reducing crew intervention during plant cultivation except for maintenance and harvesting events. Eventually, AI driven control systems that include autonomous planting, growing, and harvesting as well as periodic sanitization need evaluation for supplementing crew diets with fresh produce during future Mars exploration missions.

O Monje↗

Diagnostic experiments at a 3 MeV test stand at Rutherford Appleton Laboratory (United Kingdom)

A front end is currently under construction consisting of a H{sup -} Penning ion source (65 keV, 60 mA), low energy beam transport (LEBT), and radio frequency quadrupole (3 MeV output energy) with a medium energy beam transport suitable for high power proton applications. Diagnostics can be divided either in destructive techniques such as beam profile monitor, pepperpot, slit-slit emittance scanner (preferably used during commissioning) or nondestructive, permanently installed devices such as photodetachment-based techniques. Another way to determine beam distributions is a scintillator with charge-coupled device camera. First experiments have been performed to control the beam injection into the LEBT. The influence of beam parameters such as particle energy and space-charge compensation on the two-dimensional distribution and profiles will be presented.

43 PARTICLE ACCELERATORS↗

Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor

Online detection techniques to monitor the health of rotating engine components are becoming increasingly attractive to aircraft engine manufacturers in order to increase safety of operation and lower maintenance costs. Health monitoring remains a challenge to easily implement, especially in the presence of scattered loading conditions, crack size, component geometry, and materials properties. The current trend, however, is to utilize noninvasive types of health monitoring or nondestructive techniques to detect hidden flaws and mini-cracks before any catastrophic event occurs. These techniques go further to evaluate material discontinuities and other anomalies that have grown to the level of critical defects that can lead to failure. Generally, health monitoring is highly dependent on sensor systems capable of performing in various engine environmental conditions and able to transmit a signal upon a predetermined crack length, while acting in a neutral form upon the overall performance of the engine system.

Abdul-Aziz, Ali↗

Seed morphology and anatomy and its utility in recognizing subfamilies and tribes of Zingiberaceae

PREMISE OF THE STUDY: Recent phylogenetic analyses based on molecular data suggested that the monocot family Zingiberaceae be separated into four subfamilies and four tribes. Robust morphological characters to support these clades are lacking. Seeds were analyzed in a phylogenetic context to test independently the circumscription of clades and to better understand evolution of seed characters within Zingiberaceae. METHODS: Seventy-five species from three of the four subfamilies were analyzed using synchrotron based x-ray tomographic microscopy (SRXTM) and scored for 39 morphoanatomical characters. KEY RESULTS: Zingiberaceae seeds are some of the most structurally complex seeds in angiosperms. No single seed character was found to distinguish each subfamily, but combinations of characters were found to differentiate between the subfamilies. Recognition of the tribes based on seeds was possible for Globbeae, but not for Alpinieae, Riedelieae, or Zingibereae, due to considerable variation. CONCLUSIONS: SRXTM is an excellent, nondestructive tool to capture morphoanatomical variation of seeds and allows for the study of taxa with limited material available. Alpinioideae, Siphonochiloideae, Tamijioideae, and Zingiberoideae are well supported based on both molecular and morphological data, including multiple seed characters. Globbeae are well supported as a distinctive tribe within the Zingiberoideae, but no other tribe could be differentiated using seeds due to considerable homoplasy when compared with currently accepted relationships based on molecular data. Novel seed characters suggest tribal affinities for two currently unplaced Zingiberaceae taxa: Siliquamomum may be related to Riedelieae and Monolophus to Zingibereae, but further work is needed before formal revision of the family.

aril↗

Thermal Effusivity Tomography from Pulsed Thermal Imaging

The software program generates 3D volume distribution of thermal effusivity within a test material from one—sided pulsed thermal imaging data. Thsi is the first software capable of accurate, fast and automated thermal tomographic imaging of inhomogeneoirs materials to produce 3D images similar to those obtained from 3D X—ray CT (all previous thepnal—imaging software can only produce 20 results) . Because thermal effusivity is an Intrisic material property that is related to material constituent, density, conductivity, etc., quantitative imaging of eftusivity allowed direct visualization of material’s internal constituent/structure and damage distributions, thereby potentially leading to quantitative prediction of other material properties such as strength. I can be therefre be used for 3D imaging of material structure in fundamental material studies, nondestructive characterization of defects/flaws in structural engineering components, health monitoring of material damage and degradation during service, and medical imaging and diagnostics. This technology is one—sided, non contact and sensitive to material’s thermal property and discontinuity. One major advantage of this tomographic technology over x-ray CT and ultrasounds is its natural efficiency for 3D imaging of the volume under a large surface area. This software is implemented with a method for thermal computed tomography of thermal effusivity from one—sided pulsed thermal imaging (or thermography) data. The method is based on several solutions of the governing heat transfer equation under pulsed thermography test condition. In particular, it consists of three components. 1) It utilized the thermal effusivity as the imaging parameter to construct the 3D image. 2) It established a relationship between the space (depth) and the time, because thermography data are in the time domain. 3) It incorporated a deconvolution algorithm to solve the depth porfile of the material thermal effusivity from the measured (temporal) surface temperature data. The predicted effusivity is a direct function of depth, not an average or convolved parameter, so it is an accurate (and more sensitive) representation of local property along depth.

Sun, Jiangang↗

WM-SVS-TP-003, Rev. 0, effective date 10/15/2015, WM-SVS Characterization Services User-Performed Calibration (UPC) Program

Los Alamos National Laboratory (LANL) Procedure P330-2, Control and Calibration of Measuring and Test Equipment (M&TE), requires the establishment of a Measurement Assurance Program and/or a User-Performed Calibration (UPC) Process, as applicable. This UPC has been developed in accordance with the authorization provided in QPA-VAR-2013. This program ensures that qualified individuals perform measurement control and develop measurement control and calibration procedures. Nondestructive analysis (NDA) instruments used for accountability, confirmation, and verification measurements are maintained by the Waste Management Services (WM-SVS) Characterization Services Team. NDA reference standards used for instrument control and calibration are certified for use by the Standards and Calibration Laboratory (S&CL) before use. The Characterization Services Team performs the measurements, develops procedures for performing instrument UPC, and ensures the measurement systems’ control before measurements are performed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of thermal pretreatment on the fast pyrolysis conversion of Southern Pine

Background: Thermal pretreatment of biomass ranges from simple (nondestructive) drying to more severe treatments that cause devolatization, depolymerization and carbonization. These pretreatments have demonstrated promise for transforming raw biomass into feedstock material that has improved milling, handling, storage and conversion properties. In this work, southern pine material was pretreated at 120, 180, 230 and 270 degrees C, and then subjected to pyrolysis tests in a continuous-feed bubbling-fluid bed pyrolysis system. Results: High pretreatment temperatures were associated with lower specific grinding energies, higher grinding rates and lower hydrogen and oxygen contents. Higher pretreatment temperatures were also correlated with increased char production, decreased total acid number and slight decrease in the oxygen content of the pyrolysis liquid fraction. Conclusion: Thermal pretreatment has both beneficial and detrimental impacts on fast pyrolysis conversion of pine material to bio-oil, and the effect of thermal pretreatment on upgrading of pyrolysis bio-oil requires further attention.

09 BIOMASS FUELS↗

Local elastic modulus of RF sputtered HfO{sub 2} thin film by atomic force acoustic microscopy

Atomic force acoustic microscopy (AFAM) is a useful nondestructive technique for measurement of local elastic modulus of materials at nano-scale spatial resolution by measuring the contact resonance spectra for higher order modes of the AFM cantilever. The elastic modulus of RF sputtered HfO{sub 2} thin film has been measured quantitatively, using reference approach in which measurements are performed on the test and reference samples. Using AFAM, the measured elastic modulus of the HfO{sub 2} thin film is 223±27 GPa, which is in agreement with the literature value of 220±40 GPa for atomic layer deposited HfO{sub 2} thin film using nanoindentation technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Milestone report - M4FT-15OR03120210 - Multi-lab Analytical Plan for Analysis of Legacy 85 Kr Samples

Legacy samples composed of 85 Kr encapsulated in solid zeolite 5A material and five small metal tubes containing a mixture of the zeolite combined with a glass matrix resulting from hot isostatic pressing have been preserved. The samples were a result of krypton R&D encapsulation efforts in the late 1970s performed at the Idaho Chemical Processing Plant. These samples were shipped to Oak Ridge National Laboratory (ORNL) in mid-FY 2014. Upon receipt the outer shipping package was opened and the inner package removed and placed in a radiation hood. The individual capsules were double bagged as they were removed from the inner shipping pig and placed into individual glass sample bottles for further analysis. The five capsules were then x-ray imaged. Capsules 1 and 4 appear to contain an amorphous mass within the capsules. Capsule 2 clearly shows the saw marks on the capsule and a quantity of loose pellet or bead-like material remaining in the capsule. Capsule 3 shows similar bead-like material within the intact capsule. Capsule 5 was previously opened. The end of this capsule appears to have been cut off and there are additional saw marks on the side of the capsule. X-ray tomography allowed the capsules to be viewed along the three axes. Of most interest was determining whether there was any residual material in the closed end of Capsule 5. The images confirmed the presence of residual material within this capsule. The material appears to be compacted but still retains some of the bead-like morphology. A conference call was held on February 19, 2015, with participation from ORNL, Idaho National Laboratory, Sandia National Laboratories, and Pacific Northwest National Laboratory Sigma Team members. The nondestructive analysis (NDA) results were discussed, and a proposed path forward was formulated to advance this effort toward the original goals of understanding the effects of extended storage on the waste form and package. Based on the initial NDA and the fact that there are at least two breached samples it was proposed that exploratory tests be conducted with the breached specimens before opening the three intact capsules. Portions of these would be analyzed to determine the fraction of krypton/xenon remaining in the matrix and the amount of rubidium remaining in the matrix. The inner surface of the breached capsules would be examined for corrosion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring the feasibility of crack detection in plate weldments through an interposed layer of viscoelastic material.

Development of new approaches in the nondestructive evaluation of welded steel plates for large naval structures continues to be an area of interest for the DoD and the military complex. In this report we will evaluate an elastic-microwave based detection and imaging method using both numerical finite element (3D FEM) and experimental methods. The evaluation was performed on two test articles that were designed to represent critical structural components with flaws of interest. Details of the materials and the mechanical drawings were provided with the test articles. Flaws, cracks and weld defects have been included in the test articles to determine detection sensitivity and accuracy of the proposed method. Our approach uses a microwave interferometer (MI) to record the scattered response of flaws in the steel plated as it is driven by an incident elastic field. The MI can “see” (penetrate) through the viscoelastic coating to the upper surface of the plate. Out-of-plane displacement amplitudes of 10nm in the frequency range (1kHz to 25kHz) are readily observable, with the key feature being, that the surface bond between the coating and the steel plate are undisturbed. The non-contact aspect of the interferometer allows for large surface regions to be accurately and efficiently scanned in space and time. Spatiotemporal data sets of this kind and specialized wavefield processing provide powerful detection and imaging modalities. From these wavefield data sets, a plate thickness mapping capability has been demonstrated that can detect thickness changes on the order of 0.79 mm (1/32”) with spatial resolution on the order of the spatial sampling rate, 15mm (~5/8”). We have also shown that a topological energy analysis of the wavefield data can detect and locate small flaws, on the order of 5-10 mm (0.025-0.40”) in the welded joint of a 1.5” thick T-plate. As before, these results are obtained through a 2” thick viscoelastic coating without altering the integrity of coating or the coating bond. These results show that we are detecting and locating damage (flaws) in the plate that are much smaller than the wavelength of the propagating guided modes. Classical scattering theory places a (λ/2) resolution limit on the detectability of flaws in terms of the incident field [22], however, since the spatial resolution of the scanned region is much smaller, (Δx=Δy=15mm) and the inherent natural focusing of the time reversal operation, we are able to detect smaller flaws on the order of (λ/10). It is important to realize that we are not imaging the flaw but detecting and localizing a difference between a reference (pristine) sample and the measured (damaged) sample, relative to a spatial grid on the surface. The current scan resolution is 15mm x 15mm. At present we cannot expect to resolve individual flaws within a grid space only their cumulative effect. Even with the current limitations, this imaging approach appears to be a promising alternative to current methods where the coating layer is removed.

36 MATERIALS SCIENCE↗

Some effects of thermal-cycle-induced deformation in rocket thrust chambers

The deformation process observed in the hot gas side wall of rocket combustion chambers was investigaged for three different liner materials. Five thrust chambers were cycled to failure by using hydrogen and oxygen as propellants at a chamber pressure of 4.14 MN/cu m. The deformation was observed nondestructively at midlife points and destructively after failure occurred. The cyclic life results are presented with an accompanying discussion about the problems of life prediction associated with the types of failures encountered in the present work. Data indicating the deformation of the thrust chamber liner as cycles are accumulated are presented for each of the test thrust chambers. From these deformation data and observation of the failure sites it is evident that modeling the failure process as classic low cycle thermal fatigue is inadequate as a life prediction method.

Hannum, N. P.↗

Ultrasonic measurement of porosity in casts and welds

The development of a quantitative nondestructive method which involves ultrasonic attenuation measurements in frequency domain to determine volume fraction of porosity in aluminum cast is discussed. The aluminum alloy A357 casting samples were produced at the Ohio State University Foundry with controlled porosity contents ranging from 0% to 6%. A computer controlled system was used to direct ultrasonic beam to a test sample to different places to conduct ultrasonic attenuation measurements. The plot of attenuation coefficients as a function of frequency was then evaluated based on existing theories to determine volume fraction of porosity and pore size.

Adler, L.↗

Ultrasonic nondestructive diagnosis of lithium-ion batteries with multiple frequencies

Accurately estimating the state of charge (SoC) in battery management systems (BMSs) requires the measurement of numerous parameters and advanced algorithms. This work studies multifrequency ultrasonic waves to estimate the SoC of Li-ion batteries by sensing the material changes during charge/discharge. A pouch-type LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) graphite battery cell is designed and fabricated with a capacity of 2.4 Ah. Different ultrasonic testing setups are explored to determine the optimal testing parameters for the battery. An ultrasonic monitoring system is developed to monitor the battery during charge/discharge at 750 kHz, 1 MHz, and 1.5 MHz. Signal processing algorithms are proposed for extracting three ultrasonic features—amplitude, wave velocity, and attenuation. In a three-cycle test, the amplitude histories do not show clear correlations with the SoC. The wave velocities of all three frequencies have an approximately linear relationship with the SoC, which can be used for SoC estimation. Hysteresis behavior is observed for the wave velocity in terms of a larger slope in the discharge process and velocity drop after a close charge/discharge cycle. The wave attenuation is able to capture the material phase transitions during charge/discharge.

25 ENERGY STORAGE↗

Evaluation of Clamshell Current Coupler for Online Frequency Domain and Spread Spectrum Time Domain Reflectometry to Detect Anomalies in Energized Cables

This document describes adaptation and evaluation of a clamshell inductive current coupler for online reflectometry testing (both frequency domain reflectometry and spread spectrum time domain reflectometry) to evaluate cable insulation degradation and anomalies. Safety-critical nuclear power plant cables were initially qualified for 40 years. However, as plants extend their operating licenses to 60 and 80 years, justification for continued safe operation includes test and monitoring programs. These will become more important as the industry moves to condition based qualification programs. Cable test programs traditionally involve manual interventions to disconnect cables, perform one or several tests, then reconnect the systems, usually during refueling outages occurring only every 18 to 24 months. This poses an operational burden that can be minimized by online testing or periodic connection to a coupler that may remain on the cable of interest or be clamped onto the cable without de-termination. This work investigates the adaptation of a clamshell inductive current coupler for either frequency domain reflectometry or spread-spectrum time domain reflectometry. The reflectometry test instrument injects a broad-band chirp or pseudo-noise signal onto a cable conductor and monitors for a reflected signal indicative of an impedance change caused by a damage condition. The instrument maximum input signal levels are typically 10 to 30 volts or less and the instruments will be damaged if subjected to 60 Hz power line voltages of 110, 220, or 480 VAC. One commercial spread-spectrum time domain reflectometry system has circuitry suitable for voltages up to 1 kV, but typical reflectometry tests are performed on de-energized cables. The clamshell inductive coupler provides >60 dB of 60 Hz attenuation with less than 10 dB loss in the 1-500 MHz test bandwidth of interest. An energized cable was successfully tested up to 6.7 kVp-p and frequency response plots imply that the tests could be extended to 10 kV or higher energized levels.

36 MATERIALS SCIENCE↗