Search NASA⌕ Search

SEARCH · Search NASA

Results for “ORIFICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Thermal evaporation sources for wide-area deposition

A thermal evaporation source includes: a crucible configured to contain a volume of evaporant and a vapor space above the evaporant; a manifold body having within it a hollow expansion chamber that is flowably connected to the vapor space via one or more restriction orifices; one or more effusion nozzles flowably connected to the expansion chamber and exiting an outer surface of the thermal evaporation source, the nozzle(s) oriented to direct an evaporant vapor flow out of the source vertically downward, in one or more horizontal directions, or in one or more directions intermediate between horizontal and vertically downward; and a heater capable of heating some or all of the thermal evaporation source to a temperature sufficient to produce the one or more evaporant vapor flows when a vacuum is applied to the thermal evaporation source.

Birkmire, Robert W.↗

Characteristics of refrigerant leaks from small HVAC&R systems

Reduced use of high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants is desired. However, many lower-GWP alternatives are flammable, some of higher flammability levels, or A3, and others of lower flammability (A2 or A2L).Safety standards for A2 and A3 flammable refrigerants, including the International Electrotechnical Commission (IEC) standard IEC 60335-2-40 calculate maximum flammable refrigerant charge limits using a fixed 4-minute leak time based on the time to leak 150 g of CO2 through a capillary tube.Actual refrigerant leak times depend on the equipment type, leak location, leak orifice diameter and equipment operation condition (on or off).Five systems were installed in test chambers with leak quantities and rates measured by tracking total system weight during the leak event. Among the major results were that almost all of the system charge was shown to escape the units, >80% within the first 10 minutes.

Patel, Viral↗

Cooling system for fuel nozzles within combustor in a turbine engine

A cooling system for a fuel system in a turbine engine that is usable to cool a fuel nozzle is disclosed. The cooling system may include one or more cooling system housings positioned around the fuel nozzle, such that the cooling system housing forms a cooling chamber defined at least partially by an inner surface of the cooling system housing and an outer surface of the fuel nozzle. The fuel nozzle may extend into a combustor chamber formed at least in part by a combustor housing. The fuel nozzle may include one or more fuel exhaust orifices with an opening in an outer surface of the fuel nozzle and configured to exhaust fluids unrestricted by the housing forming the cooling system cooling chamber. The cooling system may provide cooling fluids to cool the fuel nozzle within the cooling system cooling chamber regardless of whether the fuel nozzle is in use.

33 ADVANCED PROPULSION SYSTEMS↗

Combustor assembly for low-emissions and alternate liquid fuels

Implementations of a combustor assembly yield low emissions, require low power, are suitable for alternate liquid fuels, including highly viscous fuels, and are scalable for various heat release rates. The combustor assembly includes a fuel injector and a swirler. The fuel injector may include a choke portion and a spacer. The choke portion is disposed just upstream of an outlet of a liquid fuel conduit and prevents atomizing gas from interrupting continuous flow of the liquid fuel through the liquid fuel conduit. The spacer is disposed downstream of the outlet to precisely control the gap and thus, bifurcation of atomizing gas flow, between the outlet of liquid fuel conduit and an inlet of an orifice plate. The swirler is disposed radially outwardly and adjacent the fuel injector and includes a plurality of angled vanes.

42 ENGINEERING↗

Bubble Generation in the SNS 2 MW Mercury Target

The accelerator at the Spallation Neutron Source is currently being upgraded to increase the proton beam power from 1.4 MW to 2.8 MW. About 2 MW will go to the first target station, while the rest will go to the future second target station. The first target station uses a mercury target. When the short proton beam pulse hits it, strong pressure waves are developed inside the mercury and the vessel itself, causing weld failures and cavitation erosion. The pressure wave can be significantly mitigated by injecting small helium bubbles into the mercury. SNS has been injecting helium since 2017 using small orifices but has met challenges in fabrication and operations with them. Thus, for the 2 MW target, swirl bubblers will be used to increase gas injection and improve reliability. A 2 MW prototypical target was built and tested in a mercury process loop available at Oak Ridge National Laboratory. Acrylic viewports on the top of the target were used to determine the bubble size distribution (BSD) generated by the swirl bubblers. It was found that the bubblers were not only capable of generating small bubbles but that the BSD was independent of gas injection rate.

Barbier, Charlotte↗

Effect of Combustion Products on Detonation Velocities

Pressure gain combustion has received increased interest in recent years because of the potential for increased thermodynamic efficiencies in propulsion and power generation applications. In pressure gain devices, mixing of fuel and oxidizer with combustion products can occur in the combustion chamber as the reactants are injected and the exhaust products are purged. Most research, however, considers only fresh reactants. This is significant because mixing can result in decreased detonation velocities. Laminar flame speed calculations show that dilution with combustion products can reduce the flame speed as a consequence of both dilution and chemistry effects. The objective of this study is to identify the effects of dilution with combustion products on detonation velocities, expanding on the results for laminar flame speed calculations. Experiments were performed using a pulse detonation engine instrumented with photodiodes to measure detonation velocities. Sonic orifices were used to meter mass flow rates of fuel (C 3 H 8 ), oxidizer (N 2 O), and combustion products (CO 2 ) or inert diluents (N 2 ). The experiments were performed such that the sensible enthalpy of the diluents was matched, thus observed velocity sensitivities indicate a chemical kinetic effect. The data indicates that non-inert diluents demonstrate a suppression in detonation velocities resulting from chemical kinetic effects. Specifically, testing with CO 2 showed a significant velocity deficit when compared to inert N 2 .

Bean, Derek↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

Airfoil with CMC liner and multi-piece monolithic ceramic shell

An airfoil includes an airfoil section that has an airfoil wall that surrounds a cavity. The airfoil wall includes an exterior monolithic ceramic shell and an interior CMC liner that has CMC plies. An outermost ply of the CMC plies forms tabs that are raised from an underlying ply so as to define a slot. The exterior monolithic ceramic shell includes an underlapping shell piece and an overlapping shell piece. The underlapping shell piece has a portion disposed in the slot and bonded with the tabs. The overlapping shell piece extends over the tabs and is bonded to the tabs. There are channels bounded by adjacent ones of the tabs, the underlapping shell piece, and the overlapping shell piece. Channel orifices through the CMC liner connect the cavity and the channels.

Martin, Thomas J.↗

Rapid manufacturing of tailored preforms

A method for rapid manufacturing of three dimensional discontinuous fiber preforms is provided. The method includes the deposition of a polymeric material containing fibers on a surface to form a tailored charge for compression molding. The reinforced polymeric material may be a thermoplastic or a reactive polymer with viscosity low enough to allow flow through an orifice during deposition, yet high enough zero shear viscosity to retain the approximate shape of the deposited charge. The material can be deposited in a predetermined pattern to induce the desired mechanical properties through alignment of the fibers. This deposition can be performed in a single layer or in multiple layers. The alignment is achieved passively by shear alignment of the fibers or actively through fiber orientation control or mixing. The fibers can be of the desired material, length, and morphology, including short and long filaments.

Kunc, Vlastimil↗

LEAKAGE CHARACTERISTICS OF A STEPPED BALANCE PISTON LABYRINTH SEAL IN SUPERCRITICAL CO2

In an integrally geared compressor, there is a net thrust load on the pinion shaft from gear loads and aerodynamic forces. The net thrust on the pinion is resolved with either a thrust bearing or a thrust collar (rider ring). As the pressure increases, this increases the aerodynamic force proportionally. In highpressure systems this can overwhelm the thrust bearing or thrust collar if thrust is mismanaged. In a recent test program for an sCO2 integrally geared compander (compressor/turbine), a balance piston was created on the opposite end of the turbine to provide an equalizing thrust; while this is not novel, the balance piston provided a test apparatus for measuring the leakage on a 20 tooth stepped labyrinth seal operating at pressures in excess of 250 bar (3600 psi). The stepped balance piston seal is a 20 tooth tooth-onrotor balance piston seal. This type of seal was selected since it was predicted to have substantially less leakage than a comparably sized straight through labyrinth seal. Comparisons between the two designs will be made, showing that the leakage of the stepped balance piston seal is considerably lower. The tooth clearance on the seal was selected to be 30 mils radial. While this seems large, a stack-up tolerance assessment showed that this magnitude of clearance was appropriate to prevent rotor stator contact. During the testing campaign, data was recorded showing the leakage across this stepped balance piston seal at pressures in excess of 250 bar (3600 psi) with a pressure ratio of 2. This leakage data was measured, and will be compared to leakage data predicted with CFD. Two measurement methods are presented for the stepped balance piston seal: an orifice plate and valve. The predicted seal leakage from a straight through seal was four times that of the predicted stepped labyrinth seal. The measured flow from the stepped seal was on the same order as the CFD prediction and offered adequate rotordynamic performance

wilkes, jason↗

Local control robotic surgical devices and related methods

The various robotic medical devices include robotic devices that are disposed within a body cavity and positioned using a support component disposed through an orifice or opening in the body cavity. Additional embodiments relate to devices having arms coupled to a device body wherein the device has a minimal profile such that the device can be easily inserted through smaller incisions in comparison to other devices without such a small profile. Further embodiments relate to methods of operating the above devices.

Markvicka, Eric↗

The feasibility study of hot cell decontamination by the PFC spray method

The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to be reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation Pilot Plant. Korea Atomic Energy Research Institute (KAERI) is developing dry decontamination technologies applicable to a decontamination of a highly radioactive area loosely contaminated with radioactive particles. This contamination has occurred as a result of an examination of a post-irradiated material or the development of the DUPIC process. The dry decontamination technologies developed are the carbon dioxide pellet spray method and the PFC spray method. As a part of the project, PFC ultrasonic decontamination technology was developed in 2004. The PFC spray decontamination method which is based on the test results of the PFC ultrasonic method has been under development since 2005. The developed PFC spray decontamination equipment consists of four modules (spray, collection, filtration and distillation). Vacuum cup of the collection module gathers the contaminated PFC solution, then the solution is moved to the filtration module and it is recycled. After a multiple recycling of the spent PFC solution, it is purified in the distillation module. A performance test on each module was executed and the results have been reported. A combined test of the four modules, however, has not been performed as yet. The main objective of the present study is to demonstrate the feasibility of the full PFC spray decontamination process. Decontamination of the inside of the IMEF hot cell by the PFC spray method was also performed. PFC spray decontamination process was demonstrated by using a surrogate wall contaminated with Eu{sub 2}O{sub 3} powder. The spray pressure was 41 kgf/cm{sup 2}, the orifice diameter was 0.2 mm and the spray velocity was 0.2 L/min. And, the decontaminated area was 100 cm{sup 2}. From previous test results, we found that the decontamination factor of the PFC spray method was in the range from 9.6 to 62.4. When the decontamination efficiency of Co-60 was high, then the decontamination efficiency of Cs-137 was also high. As the surface roughness of the specimen increased, the PFC spray decontamination efficiency decreased. Inferring from the previous results, the surface of the surrogate wall was cleaned by the PFC spray method. The vacuum cup of the collection module operated well and gathered more than 99 % of the PFC solution. Also, filtration and distillation modules operated well. All the filtered PFC solution flowed to the storage chamber where some of the PFC solution was distilled. The coolant of the distillation module was a dry ice. And, the recycled solution was transferred to the spray module by a high pressure pump. To evaluate the PFC spray decontamination efficiency, a smear device was fabricated and operated by a manipulator. Before and after decontamination, a smear test was performed. The tested area was 100 cm{sup 2} and the radioactivity was estimated indirectly by measuring the radioactivity of the filter paper. The average decontamination factor was in the range between 10 and 15. One application time was 2 minutes. The sprayed PFC solution was collected by the vacuum cup and it was stored in the collection equipment. After the termination of the decontamination test, the flexible hose was cut near a toboggan. The collection equipment that contained the spent PFC solution, vacuum cup, spray nozzle and the flexible hose was stored in a radioactive waste storage tank. A feasibility study for the PFC spray decontamination method for an application to a hot cell surface was performed. The decontamination equipment that consisted of four modules operated well in the hot cell. The collection module gathered the sprayed PFC solution. The solution was purified in the filtration or distillation modules. The main characteristic of the distillation module is the use of dry ice as a coolant. The decontamination factor of IMEF hot cell was in the range from 10 to 15. It was difficult to measure the radioactivity accurately at a given time. We, however, concluded that the PFC spray decontamination method is a promising technology. It generated a small amount of secondary waste and used a non-toxic and non-conducting material. Decontamination work was performed with a little loss of the main decontamination agent. Based on the test results, we are developing an improved PFC spray decontamination process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A 100 MWe advanced sodium-cooled fast reactor core concept

An Advanced sodium-cooled Fast Reactor core concept (AFR-100) was developed targeting a small electrical grid to be transportable to the plant site and operable for a long time without frequent refueling. The reactor power rating was strategically decided to be 100 MWe, and the core barrel diameter was limited to 3.0 m for transportability. The design parameters were determined by relaxing the peak fast fluence limit and bulk coolant outlet temperature to beyond irradiation experience assuming that advanced cladding and structural materials developed under US-DOE programs would be available when the AFR-100 is deployed. With a de-rated power density and U-Zr binary metallic fuel, the AFR-100 can maintain criticality for 30 years without refueling. The average discharge burnup of 101 MWd/kg is comparable to conventional design values, but the peak discharge fast fluence of {approx}6x10{sup 23} neutrons/cm{sup 2} is beyond the current irradiation experiences with HT-9 cladding. The evaluated reactivity coefficients provide sufficient negative feedbacks and the reactivity control systems provide sufficient shutdown margins. The integral reactivity parameters obtained from quasi-static reactivity balance analysis indicate that the AFR-100 meets the sufficient conditions for acceptable asymptotic core outlet temperature following postulated unprotected accidents. Additionally, the AFR-100 has sufficient thermal margins by grouping the fuel assemblies into eight orifice zones. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A scaling study of the natural circulation flow of the ex-vessel core catcher cooling system of EU-APR1400 for designing a scale-down test facility for design verification

In this paper a scaling study on the steady state natural circulation flow along the flow path of the ex vessel core catcher cooling system of EU-APR1400 is described, and the scaling criteria for reproducing the same steady state thermalhydraulic characteristics of the natural circulation flow as a prototype core catcher cooling system in the scale-down test facility are derived in terms of the down-comer pipe diameter and orifice resistance. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Grout Isolation and Stabilization of Structures and Materials within Nuclear Facilities at the U.S. Department of Energy, Hanford Site, Summary - 12309

Per regulatory agreement and facility closure design, U.S. Department of Energy Hanford Site nuclear fuel cycle structures and materials require in situ isolation in perpetuity and/or interim physicochemical stabilization as a part of final disposal or interim waste removal, respectively. To this end, grout materials are being used to encase facilities structures or are being incorporated within structures containing hazardous and radioactive contaminants. Facilities where grout materials have been recently used for isolation and stabilization include: (1) spent fuel separations, (2) uranium trioxide calcining, (3) reactor fuel storage basin, (4) reactor fuel cooling basin transport rail tanker cars and casks, (5) cold vacuum drying and reactor fuel load-out, and (6) plutonium fuel metal finishing. Grout components primarily include: (1) portland cement, (2) fly ash, (3) aggregate, and (4) chemical admixtures. Mix designs for these typically include aggregate and non aggregate slurries and bulk powders. Placement equipment includes: (1) concrete piston line pump or boom pump truck for grout slurry, (2) progressive cavity and shearing vortex pump systems, and (3) extendable boom fork lift for bulk powder dry grout mix. Grout slurries placed within the interior of facilities were typically conveyed utilizing large diameter slick line and the equivalent diameter flexible high pressure concrete conveyance hose. Other facilities requirements dictated use of much smaller diameter flexible grout conveyance hose. Placement required direct operator location within facilities structures in most cases, whereas due to radiological dose concerns, placement has also been completed remotely with significant standoff distances. Grout performance during placement and subsequent to placement often required unique design. For example, grout placed in fuel basin structures to serve as interim stabilization materials required sufficient bearing i.e., unconfined compressive strength, to sustain heavy equipment yet, low breakout force to permit efficient removal by track hoe bucket or equivalent construction equipment. Further, flow of slurries through small orifice geometries of moderate head pressures was another typical design requirement. Phase separation of less than 1 percent was a typical design requirement for slurries. On the order of 30,000 cubic meters of cementitious grout have recently been placed in the above noted U.S. Department of Energy Hanford Site facilities or structures. Each has presented a unique challenge in mix design, equipment, grout injection or placement, and ultimate facility or structure performance. Unconfined compressive and shear strength, flow, density, mass attenuation coefficient, phase separation, air content, wash-out, parameters and others, unique to each facility or structure, dictate the grout mix design for each. Each mix design was tested under laboratory and scaled field conditions as a precursor to field deployment. Further, after injection or placement of each grout formulation, the material was field inspected either by standard laboratory testing protocols, direct physical evaluation, or both. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Graphene: a Barrier to Hydrogen Permeation

Small area freestanding monolayer graphene has been shown to be impermeable to standard gases including hydrogen and helium.1 Several recent reports have suggested that graphene can be used as a hydrogen permeation barrier on metals.2 Those studies have relied on electrochemical hydrogen permeation measurements, which do a good job reproducing bulk permeability compared to gaseous diffusion but do not always reflect the real surface effects due to the difference in driving forces. This problem is magnified when measuring the permeability of thin coatings, which are dominated by surface effects. For this reason, we performed gas driven hydrogen permeation measurements of graphene coated metal samples. The diffusion of hydrogen through a metal can be described using Fick's and Sievert's Laws. Graphene-coated copper foils were prepared using chemical vapor deposition (CVD) with a methane precursor. Photo-reduced graphene samples were prepared by first sputtering a layer (∼15 nm) of copper on top of stainless steel foils. Graphene oxide in ethanol solutions were then drop cast on the surface and photo reduced using a neon lamp. A custom-designed apparatus has been assembled for measuring the hydrogen permeability of various materials. The operating principle of the system is as follows: A sample is sealed between the fore-sample and post-sample chambers using standard vacuum gaskets. Hydrogen is introduced into the fore sample region at varying pressures while the post sample region is maintained under high vacuum. Due to the concentration gradient, hydrogen then diffuses through the material and is detected using a quadrupole mass spectrometer. This process is repeated at several temperatures. The mass spectrometer was calibrated using an orifice with known conductance in place of the sample. Data collection and reduction were automated using scripts written in LabVIEW and Octave, respectively. We saw a decrease in the hydrogen permeability of copper after adding graphene to the surface for small temperature steps. This result is also observed when considering temperature steps of 20 K. Future Work: Apply this methodology to graphene-coated 316L stainless steel. The hydrogen permeability of 316L steel should also decrease with the addition of graphene to the surface. Determine methods for graphene defect reduction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal hydraulic issues of HTGR helical tube once through steam generator: methods and applications - 18478

High Temperature Gas-cooled Reactor (HTGR) usually uses helical tube once through steam generators (OTSG) for steam generation. The most concerned thermal hydraulic issues of HTGR helical tube OTSG are two phase flow instability and temperature non-uniformity. One dimensional transient code and two dimensional code are developed to investigate these two issues. The codes are briefly introduced, then the results are briefly presented and discussed. The main conclusions are that there does not appear two phase instability for all the working conditions for the steam generator of HTR-PM. Tube plugging can introduce temperature non-uniformity in the tube bundle. The temperature non-uniformity can be evened by changing the flow rate distribution through adjusting the throttle orifice at the inlet. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity Analysis of an Experimental Breeder Reactor II Fuel Assembly

The Experimental Breeder Reactor II (EBR-II) was selected as a candidate for a reactor physics benchmark evaluation due to its unique features and capabilities. In connection with the benchmark evaluation, the goal of this work was to perform a sensitivity analysis. The EBR-II was a sodium cooled, pool type, metal fueled, fast spectrum reactor. EBR-II operated from 1964 through 1994. It had a maximum heat output of 62.5 MW which could produce 20 MW of electricity. The design of EBR-II consisted of 637 hexagonal shaped, removable assemblies. The assemblies were divided into three regions: the core, an inner blanket, and an outer blanket. The core region contained assemblies with 91 fuel rods in each. The fuel was enriched uranium metal and was clad within stainless steel. The core region also included two safety assemblies and eight control assemblies with the difference being that these assemblies only contained 61 fuel rods. Additional assemblies in the core region included stainless steel dummies, half worth drivers, and experimental/instrumentation assemblies. The inner blanket region initially consisted of depleted uranium for fuel breeding, but was replaced, after proving the concept of breeding, with stainless steel reflectors for the purpose of irradiation. The outer blanket region consisted of depleted uranium. Figure 1 shows a cross section view of the EBR-II core layout. Each assembly was approximately 234 cm long with the uranium fuel section being 33 cm long. Above and below the fuel were stainless steel neutron reflectors. Additionally, orifices at the bottom of the assembly allowed for sodium coolant to flow upward, with larger holes in the subassemblies at the center where the greatest heat was produced. The core of EBR-II was enclosed by a stainless steel reactor vessel which was comprised of a radial shell, a lower grid plenum structure, and an upper reactor vessel cover that served as a neutron shield. Surrounding the reactor vessel radially were layers of graphite and borated graphite shielding. The entire assembly is submerged 3 meters in a pool of sodium. The pool contained up to 337,000 liters of sodium which was forced through the core and blanket regions using two centrifugal pumps that were also submerged within the sodium pool. The design of EBR-II included many safety features. The compatibility between the sodium and stainless steel prevented corrosion and therefore the risk of a radioactive release due to corrosion. The sodium coolant was kept at near atmospheric pressure which made any leak more controllable. The metal fuel, cladding, and coolant allowed for heat to be removed easily. The large volume of sodium allowed for heat to be absorbed without problems occurring. Lastly, the reactor would expand as temperature increased which would result in greater neutron leakage. This extra leakage caused a large negative temperature reactivity feedback which automatically shut the reactor down in case of an accident. EBR-II had unique capabilities which were proven during the Integral Fast Reactor initiative. This program lasted from 1984 to 1994. The goal of this program was to solve many of the perceived problems with nuclear energy through scientific means. The safety features of EBR-II were put to the test in April 1986. The tests simulated loss of reactor coolant flow and loss of a heat sink. For both of these tests, the reactor was at 100% power and was not scrammed. During both tests, the reactor shut itself down and achieved a safe steady state temperature all due to the design of the reactor. It was because of these tests that EBR-II was chosen for a reactor physics benchmark evaluation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗