Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Long-pulse generation with a stable-relaxation-oscillation Nd:YLF laser

A simple technique for long-pulse (0.2-2 microsec) generation with neodymium lasers has been demonstrated. Under the proper conditions, a normal-mode oscillator, operated in a single transverse mode, produces well-defined relaxation oscillations from which a single subpulse can be isolated for amplification. The characteristic subpulse temporal profile is ideal for saturated amplification without pulse shortening. Data are presented for a Nd:YLF system consisting of an oscillator followed by a 64-nm-long amplifier. Pulse energies in excess of 100 mJ were achieved with a small-signal gain of 630.

Harisson, J.↗

Development of magnetostrictive active members for control of space structures

The goal of this Phase 2 Small Business Innovative Research (SBIR) project was to determine the technical feasibility of developing magnetostrictive active members for use as truss elements in space structures. Active members control elastic vibrations of truss-based space structures and integrate the functions of truss structure element, actively controlled actuator, and sensor. The active members must control structural motion to the sub-micron level and, for many proposed space applications, work at cryogenic temperatures. Under this program both room temperature and cryogenic temperature magnetostrictive active members were designed, fabricated, and tested. The results of these performance tests indicated that room temperature magnetostrictive actuators feature higher strain, stiffness, and force capability with lower amplifier requirements than similarly sized piezoelectric or electrostrictive active members, at the cost of higher mass. Two different cryogenic temperature magnetostrictive materials were tested at liquid nitrogen temperatures, both with larger strain capability than the room temperature magnetostrictive materials. The cryogenic active member development included the design and fabrication of a cryostat that allows operation of the cryogenic active member in a space structure testbed.

Johnson, Bruce G.↗

Artificial Neural Network with Hardware Training and Hardware Refresh

A neural network circuit is provided having a plurality of circuits capable of charge storage. Also provided is a plurality of circuits each coupled to at least one of the plurality of charge storage circuits and constructed to generate an output in accordance with a neuron transfer function. Each of a plurality of circuits is coupled to one of the plurality of neuron transfer function circuits and constructed to generate a derivative of the output. A weight update circuit updates the charge storage circuits based upon output from the plurality of transfer function circuits and output from the plurality of derivative circuits. In preferred embodiments, separate training and validation networks share the same set of charge storage circuits and may operate concurrently. The validation network has a separate transfer function circuits each being coupled to the charge storage circuits so as to replicate the training network s coupling of the plurality of charge storage to the plurality of transfer function circuits. The plurality of transfer function circuits may be constructed each having a transconductance amplifier providing differential currents combined to provide an output in accordance with a transfer function. The derivative circuits may have a circuit constructed to generate a biased differential currents combined so as to provide the derivative of the transfer function.

Tuan A Duong↗

Extended Characterization of the Common-Source and Common-Gate Amplifiers using a Metal-Ferroelectric-Semiconductor Field Effect Transistor

Collected data for both common-source and common-gate amplifiers is presented in this paper. Characterizations of the two amplifier circuits using metal-ferroelectric-semiconductor field effect transistors (MFSFETs) are developed with wider input frequency ranges and varying device sizes compared to earlier characterizations. The effects of the ferroelectric layer's capacitance and variation load, quiescent point, or input signal on each circuit are discussed. Comparisons between the MFSFET and MOSFET circuit operation and performance are discussed at length as well as applications and advantages for the MFSFETs.

Hunt, Mitchell↗

Multiplexing of Hot-Electron Nanobolometers Using Microwave SQUIDs

We have obtained the first data on the multiplexed operation of titanium hot-electron bolometers (HEB). Because of their low thermal conductance and small electron heat capacity nanobolometers are particularly interesting as sensors for far-infrared spectroscopy and mid- and near-IR calorimetry. However, the short time constant of these devices (approximately microseconds at 300-400 mK) makes time domain or audio-frequency domain multiplexing impractical. The Microwave SQUID (MSQUID) approach pursued in this work uses dc SQUIDs coupled to X-band microresonators which are, in turn, coupled to a transmission line. We used a 4-element array of Ti HEBs operated at 415 mK in a He3 dewar with an optical fiber access. The microwave signal exhibited 10-MHz wide resonances at individual MSQUD frequencies between 9 GHz and 10 GHz. The resonance depth is modulated by the current through the bolometer via a change of the SQUID flux state. The transmitted signal was amplified by a cryogenic amplifier and downconverted to baseband using an IQ mixer. A 1-dB per ??/2 responsivity was sufficient for keeping the system noise at the level of ~ 2 pA/Hz1/2. This is more than an order of magnitude smaller than phonon noise in the HEB. The devices were able to detect single near- IR photons (1550 nm) with a time constant of 3.5 ?s. Follow-on work will scale the array to larger size and will address the microwave frequency signal generation and processing using a digital transceiver.

microwave readout↗

NASA’s Laser Communications Relay Demonstration (LCRD) Experiment Program: Characterization And Initial Operations

The National Aeronautics and Space Administration’s (NASA) Laser Communications Relay Demonstration (LCRD) completed the first 18 months of its Experiment Program in December 2023. The LCRD geosynchronous payload includes two laser communications terminals interconnected via an onboard electronic switch. The payload can relay information between any two of a set of three ground stations. Two optical ground stations are located in California and Hawaii, and an RF ground station is located in New Mexico. Experiments to date have included demonstration of optimetrics, demonstrations of Delay/Disruption Tolerant Networking (DTN), and measurements of the effects of the atmosphere (turbulence, weather) on the performance and availability of lasercom (pointing, tracking, communications, and adaptive optics). Furthermore, future operational scenarios including robotic and exploration missions with various network service configurations have been emulated. This paper provides an overview and highlights of the first 18 months of LCRD experiments, and a preview of the upcoming experiments, including relaying data to and from the Integrated LCRD Low-Earth Orbit (LEO) User Modem and Amplifier Terminal (ILLUMA-T) on the International Space Station. LCRD is a joint project involving NASA Goddard Space Flight Center (GSFC), the California Institute of Technology Jet Propulsion Laboratory (JPL), and Massachusetts Institute of Technology Lincoln Laboratory (MIT LL).

David J. Israel↗

Beam-wave interaction analysis of a 42 GHz, 200 kW CW gyrotron

In this paper, the self-consistent large-signal formulation is used to study the beam-wave interaction mechanism in a gyrotron oscillator. The nonlinear interaction has been computed by solving the set of self-consistent nonlinear equations along the interaction length using numerical method. Consequently, the computation of energy, phase, output power, and efficiency of a gyrotron is made. The computed results were found to be matching with the published results. A 42 GHz, 200 kW output power gyrotron operating in TE{sub 03} mode is analysed using this analysis and results found meeting desired specifications. (author)

43 PARTICLE ACCELERATORS↗

Optically Transparent Split-Ring Antennas for 1 to 10 GHz

Split-ring antennas made from optically transparent, electrically conductive films have been invented for applications in which there are requirements for compact antennas capable of operation over much or all of the frequency band from 1 to 10 GHz. Primary examples of such applications include wireless local-area networks and industrial, scientific, and medical (ISM) applications. These antennas can be conveniently located on such surfaces as those of automobile windows and display screens of diverse hand-held electronic units. They are fabricated by conventional printed-circuit techniques and can easily be integrated with solid-state amplifier circuits to enhance gain. The structure of an antenna of this type includes an antenna/feed layer supported on the top or outer face of a dielectric (e.g., glass) and, optionally, a ground layer on the bottom or inner face of the substrate. The ring can be in the form of either a conductive strip or a slot in the antenna/feed layer. The ring can be of rectangular, square, circular, elliptical, or other suitable shape and can be excited by means of a microstrip, slot line, or coplanar waveguide. For example, the antenna shown in the figure features a square conductive-strip split ring with a microstrip feed. In general, an antenna fed at its external boundary in the manner of this invention presents very high impedance, thereby creating an impedance-matching problem. Splitting the ring . that is, cutting a notch through the ring . offers a solution to the problem in that the notch fixes the location of maximum electric field, which location is directly related to the impedance. Thus, an excellent impedance match can be achieved through proper choice of the location of the notch. In geometric layout, such a ring antenna structure is typically between 1.4 and 1.3 the size of a patch antenna capable of operating in the same frequency range. This miniaturization of the antenna is desirable, not only because it contributes to overall miniaturization of equipment, but also because minimization of the extent of the optically transparent, electrically conductive film helps to minimize the electrical loss associated with the surface resistance ( 5 ohms per square) of the transparent, electrically conductive film material. Incidentally, even at 5 ohms per square, this surface resistance is significantly less than that of indium tin oxide film (typically > 25 ohms per square), which, heretofore has been the transparent, electrically conductive film material of choice. At the time of writing this article, information on the composition of the lower-resistance film used in the antennas of this invention was not available.

Lee, Richard Q.↗

Linear operating region in the ozone dial photon counting system

Ozone is a relatively unstable molecule found in Earth's atmosphere. An ozone molecule is made up of three atoms of oxygen. Depending on where ozone resides, it can protect or harm life on Earth. High in the atmosphere, about 15 miles up, ozone acts as a shield to protect Earth's surface from the sun's harmful ultraviolet radiation. Without this shield, we would be more susceptible to skin cancer, cataracts, and impaired immune systems. Closer to Earth, in the air we breathe, ozone is a harmful pollutant that causes damage to lung tissue and plants. Since the early 1980's, airborne lidar systems have been used for making measurements of ozone. The differential absorption lidar (DIAL) technique is used in the remote measurement of O3. This system allows the O3 to be measured as function of the range in the atmosphere. Two frequency-doubled Nd:YAG lasers are used to pump tunable dye lasers. The lasers are operating at 289 nm for the DIAL on-line wavelength of O3, and the other one is operated at 300 nm for the off-line wavelength. The DIAL wavelengths are produced in sequential laser pulses with a time separation of 300 micro s. The backscattered laser energy is collected by telescopes and measured using photon counting systems. The photon counting system measures the light signal by making use of the photon nature of light. The output pulse from the Photo-Multiplier Tube (PE), caused by a photon striking the PMT photo-cathode, is amplified and passed to a pulse height discriminator. The peak value of the pulse is compared to a reference voltage (discrimination level). If the pulse amplitude exceeds the discrimination level, the discriminator generates a standard pulse which is counted by the digital counter. Non-linearity in the system is caused by the overlapping of pulses and the finite response time of the electronics. At low count rates one expects the system to register one event for each output pulse from the PMT corresponding to a photon incident upon the photocathode, however, at higher rates the limitations of the discrimination/counting system will cause the observed count rate to be non-linear with respect to the true count rate. Depending on the pulse height distribution and the discriminator level, the overlapping of pulses (pulse pile-up) can cause count loss or even an additional apparent count gain as the signal levels increase. Characterization of the system, including the pulse height distribution, the signal to noise ratio, and the effect of the discriminator threshold level, is critical in maximizing the linear operating region of the system, thus greatly increasing the useful dynamic range of the system.

Andrawis, Madeleine↗

HYMOSS signal processing for pushbroom spectral imaging

The objective of the Pushbroom Spectral Imaging Program was to develop on-focal plane electronics which compensate for detector array non-uniformities. The approach taken was to implement a simple two point calibration algorithm on focal plane which allows for offset and linear gain correction. The key on focal plane features which made this technique feasible was the use of a high quality transimpedance amplifier (TIA) and an analog-to-digital converter for each detector channel. Gain compensation is accomplished by varying the feedback capacitance of the integrate and dump TIA. Offset correction is performed by storing offsets in a special on focal plane offset register and digitally subtracting the offsets from the readout data during the multiplexing operation. A custom integrated circuit was designed, fabricated, and tested on this program which proved that nonuniformity compensated, analog-to-digital converting circuits may be used to read out infrared detectors. Irvine Sensors Corporation (ISC) successfully demonstrated the following innovative on-focal-plane functions that allow for correction of detector non-uniformities. Most of the circuit functions demonstrated on this program are finding their way onto future IC's because of their impact on reduced downstream processing, increased focal plane performance, simplified focal plane control, reduced number of dewar connections, as well as the noise immunity of a digital interface dewar. The potential commercial applications for this integrated circuit are primarily in imaging systems. These imaging systems may be used for: security monitoring systems, manufacturing process monitoring, robotics, and for spectral imaging when used in analytical instrumentation.

Ludwig, David E.↗

Radiation detector using a graphene amplifier layer

A radiation field is detected or imaged using one or more junction devices in which a two-dimensional conductor layer is capacitively coupled to a semiconductor absorber layer. In the junction devices, pixel-level amplification and read-out are accomplished through the photogating of the devices by absorption within the absorber layer while it is in a state of deep depletion. When the two-dimensional conductor is graphene, we refer to a device operating in that manner as a deeply depleted graphene-oxide-semiconductor (D 2 GOS) detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CdZnTe Image Detectors for Hard-X-Ray Telescopes

Arrays of CdZnTe photodetectors and associated electronic circuitry have been built and tested in a continuing effort to develop focal-plane image sensor systems for hard-x-ray telescopes. Each array contains 24 by 44 pixels at a pitch of 498 m. The detector designs are optimized to obtain low power demand with high spectral resolution in the photon- energy range of 5 to 100 keV. More precisely, each detector array is a hybrid of a CdZnTe photodetector array and an application-specific integrated circuit (ASIC) containing an array of amplifiers in the same pixel pattern as that of the detectors. The array is fabricated on a single crystal of CdZnTe having dimensions of 23.6 by 12.9 by 2 mm. The detector-array cathode is a monolithic platinum contact. On the anode plane, the contact metal is patterned into the aforementioned pixel array, surrounded by a guard ring that is 1 mm wide on three sides and is 0.1 mm wide on the fourth side so that two such detector arrays can be placed side-by-side to form a roughly square sensor area with minimal dead area between them. Figure 1 shows two anode patterns. One pattern features larger pixel anode contacts, with a 30-m gap between them. The other pattern features smaller pixel anode contacts plus a contact for a shaping electrode in the form of a grid that separates all the pixels. In operation, the grid is held at a potential intermediate between the cathode and anode potentials to steer electric charges toward the anode in order to reduce the loss of charges in the inter-anode gaps. The CdZnTe photodetector array is mechanically and electrically connected to the ASIC (see Figure 2), either by use of indium bump bonds or by use of conductive epoxy bumps on the CdZnTe array joined to gold bumps on the ASIC. Hence, the output of each pixel detector is fed to its own amplifier chain.

Chen, C. M. Hubert↗

Mode selection and resonator design studies of a 95 GHz, 100 kW, CW gyrotron

In this paper, the mode selection procedure leading to the design and the cavity resonator design studies of a 95 GHz, 100 kW, CW Gyrotron will be presented, such a gyrotron will be used for specific ECRH/ECRIS applications. In this course all the suitable modes with design constraints within the limits of design goals are considered and finally the TE{sub 10.4} mode is chosen as the operating mode which is suitable for the design. Design constraints are carefully investigated, and starting currents are computed. (author)

43 PARTICLE ACCELERATORS↗

An innovative approach for performance enhancement of 320 Gbps free space optical communication system over turbulent channel

Free space optical (FSO) communication systems have recently gained huge attention as possible last mile solution in delivering high speed data services for terrestrial applications. However the FSO link performance, particularly the link range is significantly limited by the severity of atmospheric adversities affecting the channel. In this paper we advocate the use of multi-hop relay techniques to transmit wavelength division multiplexed (WDM) signal over the FSO channel. Since weather induced impairments in FSO links are distance dependent phenomena, hence relay transmission allows substantial performance enhancement by alleviating channel losses while, WDM provides cost effective solution in improving the transmission capacity. With aggregate link losses as high as 40 dB/km, the proposed 32 channel—10 Gbps (320 Gbps) FSO link has been evaluated by comparing bit error rate (BER) performances and eye patterns over different turbulent regimes. Gain optimized EDFA amplification and conventional electrical amplification have been employed to realize amplify-and-forward (A–F) multi-hop transmission in the proposed link with the former delivering more inspiring BER performance of over the latter. Our simulation results indicate that for receiver SNR of 35 dB, BER improvement up to five orders of magnitude can achieved using triple relay FSO link in contrast to direct link operating under similar conditions. Additionally, it is also observed during the analysis that for target BER of 10{sup −5}, incorporation of triple relay enhances the link range by approximately 1200 m over direct link. However on the flip side, our investigations also revealed that as the number of relay nodes is increased, the SNR gain for specified BER does increase but the magnitude of gain declines. The proposed link was designed and investigated using OptiSystem™ 14.2.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental investigation of nonlinear operation mode of a DP-QPSK 100G link with co-propagating-pump Raman amplification

The nonlinear interference noise in a coherent single-span fibre-optic communication link (FOCL) with co-propagating Raman amplification is investigated at different levels of input Raman pump and channel powers and dispersion. A simple phenomenological expression for calculating the nonlinear noise power at the output of a single-channel FOCL is presented. The merit of using a distributed Raman amplifier with co-propagating pump up to 1 W in a single-span single-channel FOCL is experimentally investigated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduction in Inflammatory Gene Expression in Skeletal Muscle from Roux-en-Y Gastric Bypass Patients Randomized to Omentectomy

To examine the effects of Roux-en-Y gastric bypass (RYGB) surgery with and without laparoscopic removal of omental fat (omentectomy) on the temporal gene expression profiles of skeletal muscle. Previously reported were the whole-body metabolic effects of a randomized, single-blinded study in patients receiving RYGB surgery stratified to receive or not receive omentectomy. In this follow up study we report on changes in skeletal muscle gene expression in a subset of 21 patients, for whom biopsies were collected preoperatively and at either 6 months or 12 months postoperatively. RNA isolated from skeletal muscle biopsies of 21 subjects (8 without omentectomy and 13 with omentectomy) taken before RYGB or at 6 and 12 months postoperatively were subjected to gene expression profiling via Exon 1.0 S/T Array and Taqman Low Density Array. Robust Multichip Analysis and gene enrichment data analysis revealed 84 genes with at least a 4-fold expression difference after surgery. At 6 and 12 months the RYGB with omentectomy group displayed a greater reduction in the expression of genes associated with skeletal muscle inflammation (ANKRD1, CDR1, CH25H, CXCL2, CX3CR1, IL8, LBP, NFIL3, SELE, SOCS3, TNFAIP3, and ZFP36) relative to the RYGB nonomentectomy group. Expressions of IL6 and CCL2 were decreased at all postoperative time points. There was differential expression of genes driving protein turnover (IGFN1, FBXW10) in both groups over time and increased expression of PAAF1 in the non-omentectomy group at 12 months. Evidence for the activation of skeletal muscle satellite cells was inferred from the up-regulation of HOXC10. The elevated post-operative expression of 22 small nucleolar RNAs and the decreased expression of the transcription factors JUNB, FOS, FOSB, ATF3 MYC, EGR1 as well as the orphan nuclear receptors NR4A1, NR4A2, NR4A3 suggest dramatic reorganizations at both the cellular and genetic levels. These data indicate that RYGB reduces skeletal muscle inflammation, and removal of omental fat further amplifies this response.

60 APPLIED LIFE SCIENCES↗

Operational Parameters, Considerations, and Design Decisions for Resource-Constrained Ion Trap Mass Spectrometers

Mass spectrometers are increasingly finding applications in new and unique areas, often in situations where key operational resources (i.e. power, weight and size) are limited. One such example is the Mars Organic Molecule Analyzer (MOMA). This instrument is a joint venture between NASA and the European Space Agency (ESA) to develop an ion trap mass spectrometer for chemical analysis on Mars. The constraints on such an instrument are significant as are the performance requirements. While the ideal operating parameters for an ion trap are generally well characterized, methods to maintain analytical performance with limited power and system weight need to be investigated and tested. Methods Experiments have been performed on two custom ion trap mass spectrometers developed as prototypes for the MOMA instrument. This hardware consists of quadrupole ion trap electrodes that are 70% the size of common commercial instrumentation. The trapping RF voltage is created with a custom tank circuit that can be tuned over a range of RF frequencies and is driven using laboratory supplies and amplifiers. The entire instrument is controlled with custom Lab VIEW software that allows a high degree of flexibility in the definition of the scan function defining the ion trap experiment. Ions are typically generated via an internal electron ionization source, however, a laser desorption source is also in development for analysis of larger intact molecules. Preliminary Data The main goals in this work have been to reduce the power required to generate the radio frequency trapping field used in an ion trap mass spectrometer. Generally minimizing the power will also reduce the volume and mass of the electronics to support the instrument. In order to achieve optimum performance, commercial instruments typically utilize RF frequencies in the 1 MHz range. Without much concern for power usage, they simply generate the voltage required to access the mass range of interest. In order to reduce the required RF voltage (and power), operation of the ion trap at lower RF frequencies has been investigated. Surprisingly, the performance of the instrument has only been slightly degraded at RF frequencies all the way down to 500 kHz. Mass resolution is relatively stable to this point and depending on the resonant ejection point used, the peak intensity is also quite stable. To date only masses up to m/z 200 have been fully investigated, however, additional studies are planned to verify the performance with higher mass ions. The lower frequency and voltage should reduce the pseudo potential well depth, eventually affecting the trapping efficiency of the instrument -- effect that could manifest itself in significantly limiting the mass range of trapped ions. Other methods to reduce the RF power while maintaining analytical performance are also under investigation. This includes ion ejection at lower q(sub z) values to access a given mass with a lower RF voltage. The loss of mass resolution at lower q(sub eject) points has been measured and current work is underway to leverage scan speed and the use of non-linear resonances in order to counter this trend. The overall trap performance under this range of operating conditions will be presented with a goal of identifying what trade-offs are acceptable.

Danell, Ryan M.↗

PRIMED for the Future: Purposing Raw Intake for Machine Learning-Enabled Detection (Final Report)

The COVID-19 pandemic demonstrated how a novel, elusive, and diffuse biological threat can engender uncertainty and misinformation, and it underscored the need for flexible analytical modalities agnostic to the identity of biological material. Yet even before the pandemic, recognition of the limitations of the current, list-based approach, which focuses on known pathogens and biotoxins, and of the importance of agent-agnostic biodetection was growing within the biosecurity community. In a 2018 report on “Biodefense in the Age of Synthetic Biology,” for example, the National Academy of Sciences stated that “an overreliance on the Select Agent List is a systematic weakness affecting many aspects of the United States’ current biodefense mitigation capability”. More recently, a group of biodefense researchers proposed the identification and adoption of “bioagent-agnostic signatures (BASs)” as a way of detecting and characterizing not only existing agents but also novel ones, an approach they believe will “enable a more flexible and resilient biodefense posture”. Indeed, the future of biodetection requires us to begin developing novel analytics that can identify anomalies and/or characteristics that indicate a potential threat, whether known or unknown, without looking for a specific signature that has been identified previously. To assess potential threats more rapidly, it is critical to develop agnostic artificial intelligence (AI)/machine learning (ML) systems that can be employed for real-time assessment of the nature and source of a perturbation. Such systems should be multi scale and multi-dimensional, integrating sensor data from a range of biological, chemical, and physical application spaces. Emerging deep learning (DL) models demonstrate exceptional promise for identification of discriminatory features within multi-dimensional datasets. DL models have the capacity to recognize and encode highly complex patterns in a wide range of input data modalities, including images, text, and biological/chemical/physical spectra. As such, they can execute a wide range of assessments and determinations that have traditionally required a human operator. The promise of advances in DL is apparent in the realm of human health and medicine. DL models have been validated for evaluating a variety of clinical threats to human health in a range of contexts, including infection and cancer, and they demonstrated improved performance in predicting stroke relative to human neurologists in some categories of data. Continuously evolving advances in AI/ML are expected to support more efficient evaluation of raw sequence, spectroscopy, and spectrometry data. For instance, recent advances and deployment of large language models (LLM) such as Generative Pre training Transformer (GPT) and Bidirectional Encoder Representations from Transformers (BERT) have already motivated application of these models for biological function prediction. As frameworks such as LLMs become larger and more complex in their representations, their capacity to serve as pre-trained models that can be fine-tuned for biological/biodetection purposes will similarly be amplified. While existing and emerging AI/ML have found broad applicability and use cases in the clinical sciences, development for environmental evaluation and biodetection has been limited. Functionalizing such capabilities for this purpose requires an understanding of the existing technical landscape and how the respective tools and algorithms are currently being employed. This landscape awareness then allows an assessment of the current practical capabilities of existing models and the anticipated requirements and development efforts that will be needed to adapt available algorithms for biodetection applications relevant to DHS. Leveraging expertise in biodetection, ML, and operational biodetection, the effort described in this report is comprised of a systematic landscape assessment (Subtask 2.1), comparative evaluation (Subtask 2.2), and formulation of a value proposition (Subtask 2.3) for the prospect of ML-enabled, agnostic biodetection from raw, or minimally-processed, datasets.

59 BASIC BIOLOGICAL SCIENCES↗