Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

SU-E-T-68: A Quality Assurance System with a Web Camera for High Dose Rate Brachytherapy

Purpose: The purpose of this work was to develop a quality assurance (QA) system for high dose rate (HDR) brachytherapy to verify the absolute position of an 192Ir source in real time and to measure dwell time and position of the source simultaneously with a movie recorded by a web camera. Methods: A web camera was fixed 15 cm above a source position check ruler to monitor and record 30 samples of the source position per second over a range of 8.0 cm, from 1425 mm to 1505 mm. Each frame had a matrix size of 480×640 in the movie. The source position was automatically quantified from the movie using in-house software (built with LabVIEW) that applied a template-matching technique. The source edge detected by the software on each frame was corrected to reduce position errors induced by incident light from an oblique direction. The dwell time was calculated by differential processing to displacement of the source. The performance of this QA system was illustrated by recording simple plans and comparing the measured dwell positions and time with the planned parameters. Results: This QA system allowed verification of the absolute position of the source in real time. The mean difference between automatic and manual detection of the source edge was 0.04 ± 0.04 mm. Absolute position error can be determined within an accuracy of 1.0 mm at dwell points of 1430, 1440, 1450, 1460, 1470, 1480, 1490, and 1500 mm, in three step sizes and dwell time errors, with an accuracy of 0.1% in more than 10.0 sec of planned time. The mean step size error was 0.1 ± 0.1 mm for a step size of 10.0 mm. Conclusion: This QA system provides quick verifications of the dwell position and time, with high accuracy, for HDR brachytherapy. This work was supported by the Japan Society for the Promotion of Science Core-to-Core program (No. 23003)

60 APPLIED LIFE SCIENCES↗

SU-F-T-242: A Method for Collision Avoidance in External Beam Radiation Therapy

Purpose: We proposed a method for collision avoidance (CA) in external beam radiation therapy (EBRT). The method encompasses the analysis of all positions of the moving components of the beam delivery system such as the treatment table and gantry, including patient specific information obtained from the CT images. This method eliminates the need for time-consuming dry-runs prior to the actual treatments. Methods: The QA procedure for EBRT requires that the collision should be checked prior to treatment. We developed a system capable of a rigorous computer simulation of all moving components including positions of the couch and gantry during the delivery, position of the patients, and imaging equipment. By running this treatment simulation it is possible to quantify and graphically represent all positions and corresponding trajectories of all points of the moving parts during the treatment delivery. The development of the workflow for implementation of the CA includes several steps: a) derivation of combined dynamic equation of motion of the EBRT delivery systems, b) developing the simulation model capable of drawing the motion trajectories of the specific points, c) developing the interface between the model and the treatment plan parameters such as couch and gantry parameters for each field. Results: The patient CT images were registered to the treatment couch so the patient dimensions were included into the simulation. The treatment field parameters were structured in the xml-file which was used as the input into the dynamic equations. The trajectories of the moving components were plotted on the same graph using the dynamic equations. If the trajectories intersect that was the signal that collision exists. Conclusion: This CA method was proved to be effective in the simulation of treatment delivery. The proper implementation of this system can potentially improve the QA program and increase the efficacy in the clinical setup.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-10: Filmless QA of CyberKnife MLC-Collimated and Iris-Collimated Fields

Purpose: Current methods of CK field shape QA is based on the use of radiochromic film. Though accurate results can be attained, these methods are prone to error, time consuming, and expensive. The techniques described herein perform similar QA using the FOIL Detector (Field, Output, and Image Localization). A key feature of this in-house QA solution, and central to this study, is an aSi flat-panel detector which provides the user with the means to perform accurate, immediate, and quantitative field analysis. Methods: The FOIL detector is automatically aligned in the CK beam using fiducial markers implanted within the detector case. Once the system is aligned, a treatment plan is delivered which irradiates the flat-panel imager using the field being tested. The current study tests each of the clinically-used fields shaped using the Iris variable-aperture collimation system using a plan which takes 6 minutes to deliver. The user is immediately provided with field diameter and beam profile, as well as a comparison to baseline values. Additionally, the detector is used to acquire and analyze leaf positions of the InCise multi-leaf collimation system. Results: Using a 6-minute plan consisting of 11 beams of 25MU-per-beam, the FOIL detector provided the user with a quantitative analysis of all clinically-used field shapes. The FOIL detector was also able to clearly resolve field edge junctions in a picket fence test, including slight over-travel of individual leaves as well as inter-leaf leakage. Conclusion: The FOIL system provided comparable field diameter and profile data when compared to methods using film; providing results much faster and with 5% of the MU used for film. When used with the MLC system, the FOIL detector provided the means for immediate quantification of the performance of the system through analysis of leaf positions in a picket fence test field. Author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts with Siemens Healthcare and Standard Imaging, Inc.

60 APPLIED LIFE SCIENCES↗

Decoherence for positive semigroups on M{sub 2}(C)

We extend Blanchard and Olkiewicz's definition of decoherence to open quantum systems whose dynamics are described by semigroups of positive (and not necessarily completely positive) operators on B(h). In particular, in the case h=C{sup 2}, we completely characterize the decomposition B(h)=M{sub 1}+M{sub 2} of B(h) in the sum of a decoherence-free part M{sub 1} and of a space M{sub 2} on which the semigroup vanishes with time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Climate variability and relationships between top‐of‐atmosphere radiation and temperatures on Earth

Abstract The monthly global and regional variability in Earth's radiation balance is examined using correlations and regressions between atmospheric temperatures and water vapor with top‐of‐atmosphere outgoing longwave (OLR), absorbed shortwave (ASR), and net radiation ( R T = ASR − OLR). Anomalous global mean monthly variability in the net radiation is surprisingly large, often more than ±1 W m −2 , and arises mainly from clouds and transient weather systems. Relationships are strongest and positive between OLR and temperatures, especially over land for tropospheric temperatures, except in the deep tropics where high sea surface temperatures are associated with deep convection, high cold cloud tops and thus less OLR but also less ASR. Tropospheric vertically averaged temperatures (surface = 150 hPa) are thus negatively correlated globally with net radiation (−0.57), implying 2.18 ± 0.10 W m −2 extra net radiation to space for 1°C increase in temperature. Water vapor is positively correlated with tropospheric temperatures and thus also negatively correlated with net radiation; however, when the temperature dependency of water vapor is statistically removed, a significant positive feedback between water vapor and net radiation is revealed globally with 0.87 W m −2 less OLR to space per millimeter of total column water vapor. The regression coefficient between global R T and tropospheric temperature becomes −2.98 W m −2 K −1 if water vapor effects are removed, slightly less than expected from blackbody radiation (−3.2 W m −2 K −1 ), suggesting a positive feedback from clouds and other processes. Robust regional structures provide additional physical insights. The observational record is too short, weather noise too great, and forcing too small to make reliable estimates of climate sensitivity.

Trenberth, Kevin E.↗

High Energy Density CNT/NaI Composite Cathodes for Sodium-Ion Batteries

The Na-iodine system has potential as a positive electrode in sodium-ion batteries due to its fast reaction kinetics and high energy density. Here, the fabrication of a NaI-loaded carbon nanotube (CNT) mat cathode is presented and the use of NaI as a Na-ion battery cathode is reported for the first time. Freestanding electrodes show a capacity retention of 92% after 100 cycles at 100 mA h g -1 and a high specific energy density (≈473 W h kg -1 , second discharge basis vs Na metal) and small hysteresis (0.03 V). Adding a CNT mat interlayer between the NaI composite cathode and the separator, and fluoroethylene carbonate to the electrolyte significantly suppresses shuttling of active materials during cycling. Using ex situ X-ray photoelectron spectroscopy and Raman data, an understanding of the relevant processes occurring during cycling of the CNT/NaI cathode is developed.

25 ENERGY STORAGE↗

Investigating the influence of particle distribution on force and torque statistics using hierarchical machine learning

An accurate representation of hydrodynamic force and torque experienced by every particle in a distribution can be obtained from particle resolved (PR) simulations. These unique quantities are influenced by the deterministic position of surrounding particles. However, systems simulated with this methodology are typically limited to particles due to the involved computational cost. This resource requirement is a major bottleneck in analyzing the effect of variations in particle distribution. Here, this article attempts to address this bottleneck by availing relatively inexpensive deep learning models. The surrogate models that we employ in this article use a physics‐based hierarchical framework and symmetry‐preserving neural networks to achieve robustness with limited training data. This article first performs additional generalizability tests on PR data of distinct distributions that are not involved in the training process. The models are then deployed on several different particle distributions. Impact of clustering and structure on the observed statistics are investigated.

42 ENGINEERING↗

-Omics potential of in vitro skin models for radiation exposure

There is a growing need to uncover biomarkers of ionizing radiation exposure that leads to a better understanding of how exposures take place, including dose type, rate, and time since exposure. As one of the first organs to be exposed to external sources of ionizing radiation, skin is uniquely positioned in terms of model systems for radiation exposure study. The simultaneous evolution of both MS-based -omics studies, as well as in vitro 3D skin models, has created the ability to develop a far more holistic understanding of how ionizing radiation affects the many interconnected biomolecular processes that occur in human skin. However, there are a limited number of studies describing the biomolecular consequences of low-dose ionizing radiation to the skin. As a result, this review will seek to explore the current state-of-the-art technology in terms of in vitro 3D skin models, as well as track the trajectory of MS-based -omics techniques and their application to ionizing radiation research, specifically, the search for biomarkers within the low-dose range.

3D tissue model↗

Parallel Spectral Acquisition with Orthogonal ICR Cells

FT-based high performance mass analyzers yield increased resolving power and mass measurement accuracy, yet require increased duration of signal acquisition that can limit many applications. The implementation of stronger magnetic fields, multiple detection electrodes for harmonic signal detection, and an array of multiple mass analyzers arranged along the magnetic field axis have been used to decrease required acquisition time. The results presented here show that multiple ion cyclotron resonance (ICR) mass analyzers can also be implemented orthogonal to the central magnetic field axis. The orthogonal ICR cell system presented here consisting of two cells (master and slave cells) was constructed with printed circuit boards and installed within a single superconducting magnet and vacuum system. A master cell was positioned, as is normally done with ICR cells, on the central magnetic field axis and a slave cell was located off this central axis, but directly adjacent and alongside the master cell. To achieve ion transfer between cells, ions that were initially trapped in the master cell were drifted across the magnetic field into the slave cell with application of a small DC field applied perpendicularly to the magnetic field axis. A subsequent population of ions was injected and accumulated in the master cell. Simultaneous excitation of cyclotron motion of ions in both cells was carried out; ICR signals from each cell were independently amplified and recorded in parallel. Presented here are the initial results of successful parallel spectral acquisition with this orthogonal dual ICR cell array. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Implanted Markers and Interportal Adjustment With Real-Time Tracking Radiotherapy System to Reduce Intrafraction Prostate Motion

Purpose: Interportal adjustment was applied to patients with prostate cancer using three fiducial markers and two sets of fluoroscopy in a real-time tumor-tracking radiotherapy (RTRT) system. The incidence of table position adjustment required to keep intrafractional uncertainty within 2.0 mm was investigated in this study. Methods and Materials: The coordinates of the center of gravity of the three fiducial markers were measured at the start of every portal irradiation in intensity-modulated radiotherapy (IMRT) with seven ports. The table position was adjusted to the planned position if the discrepancy was larger than 2.0 mm in the anterior-posterior (AP), cranial-caudal (CC), or left-right (LR) directions. In total, we analyzed 4,541 observations in 20 patients who received 70 Gy in 30 fractions (7.6 times a day on average). Results: The incidence of table position adjustment at 10 minutes from the initial setup of each treatment was 14.2%, 12.3%, and 5.0% of the observations in the AP, CC, and LR directions, respectively. The accumulated incidence of the table position adjustment was significantly higher at 10 minutes than at 2 minutes for AP (p = 0.0033) and CC (p = 0.0110) but not LR (p = 0.4296). An adjustment greater than 5 mm was required at least once in the treatment period in 11 (55%) patients. Conclusions: Interportal adjustment of table position was required in more than 10% of portal irradiations during the 10-minute period after initial setup to maintain treatment accuracy within 2.0 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multigroup diffusion solver using pseudo transient continuation for a radiation-hydrodynamic code with patch-based AMR

We present a scheme to solve the nonlinear multigroup radiation diffusion (MGD) equations. The method is incorporated into a massively parallel, multidimensional, Eulerian radiation-hydrodynamic code with Adaptive Mesh Refinement (AMR). The patch-based AMR algorithm refines in both space and time creating a hierarchy of levels, coarsest to finest. The physics modules are time-advanced using operator splitting. On each level, separate 'level-solve' packages advance the modules. Our multigroup level-solve adapts an implicit procedure which leads to a two-step iterative scheme that alternates between elliptic solves for each group with intra-cell group coupling. For robustness, we introduce pseudo transient continuation ({psi}tc). We analyze the magnitude of the {psi}tc parameter to ensure positivity of the resulting linear system, diagonal dominance and convergence of the two-step scheme. For AMR, a level defines a subdomain for refinement. For diffusive processes such as MGD, the refined level uses Dirichlet boundary data at the coarse-fine interface and the data is derived from the coarse level solution. After advancing on the fine level, an additional procedure, the sync-solve (SS), is required in order to enforce conservation. The MGD SS reduces to an elliptic solve on a combined grid for a system of G equations, where G is the number of groups. We adapt the 'partial temperature' scheme for the SS; hence, we reuse the infrastructure developed for scalar equations. Results are presented. We consider a multigroup test problem with a known analytic solution. We demonstrate utility of {psi}tc by running with increasingly larger timesteps. Lastly, we simulate the sudden release of energy Y inside an Al sphere (r = 15 cm) suspended in air at STP. For Y = 11 kT, we find that gray radiation diffusion and MGD produce similar results. However, if Y = 1 MT, the two packages yield different results. Our large Y simulation contradicts a long-standing theory and demonstrates the inadequacy of gray diffusion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Status of advanced fuel candidates for Sodium Fast Reactor within the Generation IV International Forum

The main challenge for fuels for future Sodium Fast Reactor systems is the development and qualification of a nuclear fuel sub-assembly which meets the Generation IV International Forum goals. The Advanced Fuel project investigates high burn-up minor actinide bearing fuels as well as claddings and wrappers to withstand high neutron doses and temperatures. The R&D outcome of national and collaborative programs has been collected and shared between the AF project members in order to review the capability of sub-assembly material and fuel candidates, to identify the issues and select the viable options. Based on historical experience and knowledge, both oxide and metal fuels emerge as primary options to meet the performance and the reliability goals of Generation IV SFR systems. There is a significant positive experience on carbide fuels but major issues remain to be overcome: strong in-pile swelling, atmosphere required for fabrication as well as Pu and Am losses. The irradiation performance database for nitride fuels is limited with longer term R&D activities still required. The promising core material candidates are Ferritic/Martensitic (F/M) and Oxide Dispersed Strengthened (ODS) steels.

99 GENERAL AND MISCELLANEOUS↗

CHICOX, a heavy-ion detection system for GRETA

The CHICOX detection system is an array of position sensitive parallel plate avalanche counters used for heavy ion detection in in-beam particle-gamma coincidence experiments. CHICOX, an upgrade of the CHICO2 array, is geometrically compatible with the GRETINA and GRETA gamma-ray arrays and provides an angular resolution sufficient to utilize the excellent position resolution of GRETINA/GRETA. CHICOX was successfully commissioned and fielded as an auxiliary detector to GRETINA in a campaign of stable-beam Coulomb excitation experiments at the ATLAS facility of Argonne National Laboratory. We report here on the design and in-beam performance of the CHICOX array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive high explosive neutron inspection (PHENIX): a new method to confirm the presence or absence of high explosives for nuclear treaty verification

Advanced instruments and methods need to be developed now to create a technical basis to support the negotiation of future nuclear arms control treaties. One new capability that is anticipated is the ability to confirm either the declared presence or declared absence of high explosive (HE) material in the presence of special nuclear material (SNM). Towards this goal, Passive HE Neutron Inspection (PHENIX) has been developed and demonstrated as a method for confirming the presence or absence of HE in the presence of plutonium. The method exploits the inherent presence of neutrons associated with the decay of plutonium as an internal probe source for performing prompt gamma-ray neutron activation analysis (PGNAA), searching for the presence of HE as revealed by the emission of characteristic gamma rays following neutron absorption in hydrogen and nitrogen which are building blocks of present-day, military-grade HE. Tests using stoichiometrically-correct hemishells of mock HE with plutonium show that a system can be expected to positively confirm the presence or absence of these signatures, supporting determination of HE presence or absence with Pu, in a few hours. To protect other potentially sensitive gamma-ray signatures from a treaty accountable item, an analog information barrier has been conceptualized and tested which physically prevents the collection of gamma-ray spectral data outside of user selected energy windows strategically chosen to view only narrow spectral regions corresponding to the hydrogen (2223.2 keV) and nitrogen (9807.2 keV, 10,318.2 keV, and 10,829.2 keV) PGNAA signatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Classifying topology in photonic crystal slabs with radiative environments

Abstract In the recent years, photonic Chern materials have attracted substantial interest as they feature topological edge states that are robust against disorder, promising to realize defect-agnostic integrated photonic crystal slab devices. However, the out-of-plane radiative losses in those photonic Chern slabs has been previously neglected, yielding limited accuracy for predictions of these systems’ topological protection. Here, we develop a general framework for measuring the topological protection in photonic systems, such as in photonic crystal slabs, while accounting for in-plane and out-of-plane radiative losses. Our approach relies on the spectral localizer that combines the position and Hamiltonian matrices of the system to draw a real-picture of the system’s topology. This operator-based approach to topology allows us to use an effective Hamiltonian directly derived from the full-wave Maxwell equations after discretization via finite-elements method (FEM), resulting in the full account of all the system’s physical processes. As the spectral FEM-localizer is constructed solely from FEM discretization of the system’s master equation, the proposed framework is applicable to any physical system and is compatible with commonly used FEM software. Moving forward, we anticipate the generality of the method to aid in the topological classification of a broad range of complex physical systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dipole-induced exchange bias

The discovery of dipole-induced exchange bias (EB), switching from negative to positive sign, is reported in systems where the antiferromagnet and the ferromagnet are separated by a paramagnetic spacer (AFM–PM–FM).

Chemistry↗

Automation Improvements for Synchrotron Based Small Angle Scattering Using an Inexpensive Robotics Platform

This paper reports on the progress toward creating semi-autonomous motion control platforms for beamline applications using the iRobot Create registered platform. The goal is to create beamline research instrumentation where the motion paths are based on the local environment rather than position commanded from a control system, have low integration costs and also be scalable and easily maintainable.

43 PARTICLE ACCELERATORS↗