Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Water Pump Development for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design, fabricate, and test a preflight prototype pump for use in the Extravehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump will accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting noncondensable gas without becoming "air locked." The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the preflight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES will simulate the vacuum environment in which the flight pump will operate. Testing will verify that the pump meets design requirements for range of flow rates, pressure rise, power consumption, working fluid temperature, operating time, and restart capability. Pump testing is currently scheduled for March, 2009, after which the pump will be delivered to NASA for further testing.

Schuller, Michael↗

LOCA Analysis for the NIST Research Reactor

The research reactor (aka NBSR) at the National Institute of Standards and Technology (NIST) is a heavy water cooled, moderated, and reflected tank-type research reactor that operates at atmospheric pressure and a design power of 20 MW. Core power is generated in 30 fuel elements, each with 17 fuel plates in an upper section and a separate lower section. Power is removed using forced convection and heat exchangers in the cooling loop. The licensing analysis of the loss-of-coolant accident (LOCA) in the NBSR was addressed in the current Safety Analysis Report (SAR). The SAR discusses the low probability of a significant pipe break: 'the main piping is located in protected areas, system pressures are low, and flow rates are small so that wear is not an issue.' Therefore, the probability of a large break, including a double-ended guillotine break, is extremely low. For smaller breaks where the operator has time to take action, procedures are in place to 1) mitigate a loss of water by tripping pumps and closing control valves to isolate the reactor vessel after the falling water level in the vessel is detected by instrumentation, and 2) ensure that emergency cooling water continues to flow for as long as needed. The SAR also refers to an analysis of why there is sufficient water without forced cooling to cool the fuel elements (FEs) in a LOCA if the flow channels between two fuel plates (or a fuel plate and an outside plate) remain filled with water. That analysis was based on a flooding-limited critical power but assumed that reactor trip had taken place. A more recent study showed that some scenarios may lead to the draining of water from the coolant channels. In these cases, the cooling on the inside of the fuel element is from emergency cooling water that falls only along the inner surface of one of the side plates in the fuel elements; the remaining surfaces within the fuel element being exposed to gas. The analysis therein was done for both the present high-enriched uranium fuel (HEU) and the proposed low-enriched uranium fuel (LEU). The LOCA analyses done previously assumed that there is sufficient cooling during the short-term, i.e., before the water level reaches the top of the fuel plates and begins to drain from the coolant channels or before decay heat becomes low enough such that the flooding-limited critical power shows that there is no problem. The present study is to determine if that assumption is correct, i.e., to consider the situation immediately after the break, before and after reactor trip when the power is still relatively high.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NASA Tech Briefs, May 2005

Topics covered include: Fastener Starter; Multifunctional Deployment Hinges Rigidified by Ultraviolet; Temperature-Controlled Clamping and Releasing Mechanism; Long-Range Emergency Preemption of Traffic Lights; High-Efficiency Microwave Power Amplifier; Improvements of ModalMax High-Fidelity Piezoelectric Audio Device; Alumina or Semiconductor Ribbon Waveguides at 30 to 1,000 GHz; HEMT Frequency Doubler with Output at 300 GHz; Single-Chip FPGA Azimuth Pre-Filter for SAR; Autonomous Navigation by a Mobile Robot; Software Would Largely Automate Design of Kalman Filter; Predicting Flows of Rarefied Gases; Centralized Planning for Multiple Exploratory Robots; Electronic Router; Piezo-Operated Shutter Mechanism Moves 1.5 cm; Two SMA-Actuated Miniature Mechanisms; Vortobots; Ultrasonic/Sonic Jackhammer; Removing Pathogens Using Nano-Ceramic-Fiber Filters; Satellite-Derived Management Zones; Digital Equivalent Data System for XRF Labeling of Objects; Identifying Objects via Encased X-Ray-Fluorescent Materials - the Bar Code Inside; Vacuum Attachment for XRF Scanner; Simultaneous Conoscopic Holography and Raman Spectroscopy; Adding GaAs Monolayers to InAs Quantum-Dot Lasers on (001) InP; Vibrating Optical Fibers to Make Laser Speckle Disappear; Adaptive Filtering Using Recurrent Neural Networks; and Applying Standard Interfaces to a Process-Control Language.

Source record↗

Investigation of excitation control for wind-turbine generator stability

High speed horizontal axis wind turbine generators with blades on the downwind side of the support tower require special design considerations to handle disturbances introduced by the flow wake behind the tower. Experiments and analytical analyses were made to determine benefits that might be obtained by using the generator exciter to provide system damping for reducing power fluctuations.

Gebben, V. D.↗

The Importance of Water Transport in High Conductivity and High-Power Alkaline Fuel Cells

High ionic conductivity membranes can be used to minimize ohmic losses in electrochemical devices such as fuel cells, flow batteries, and electrolyzers. Very high hydroxide conductivity was achieved through the synthesis of a norbornene-based tetrablock copolymer with an ion-exchange capacity of 3.88 meq/g. The membranes were cast with a thin polymer reinforcement layer and lightly cross-linked with N,N,N',N'-tetramethyl-1,6-hexanediamine. The norbornene polymer had a hydroxide conductivity of 212 mS/cm at 80°C. Light cross-linking helped to control the water uptake and provide mechanical stability while balancing the bound (i.e. waters of hydration) vs. free water in the films. The films showed excellent chemical stability with <1.5% conductivity loss after soaking in 1 M NaOH for 1000 h at 80°C. The aged films were analyzed by FT-IR before and after aging to confirm their chemical stability. A H 2 /O 2 alkaline polymer electrolyte fuel cell was fabricated and was able to achieve a peak power density of 3.5 W/cm 2 with a maximum current density of 9.7 A/cm 2 at 0.15 V at 80°C. The exceptionally high current and power densities were achieved by balancing and optimizing water removal and transport from the hydrogen negative electrode to the oxygen positive electrode. High water transport and thinness are critical aspects of the membrane in extending the power and current density of the cells to new record values.

08 HYDROGEN↗

In-Field Testing of Components for Feedback and Control of the ITER Disruption Mitigation System

Here, the shattered pellet injection (SPI) method has been chosen as the disruption mitigation system (DMS) for ITER. To protect the device from plasma disruptions that cause damaging heat and electromagnetic loads, SPI is used to inject high-Z material into the plasma. The process of SPI utilizes cryogenic cooling to form solid pellets. Pellets are accelerated down a barrel and into an angled surface, causing the pellet to shatter prior to entering the tokamak chamber. For the DMS to function reliably, the 27 separate shattered pellet injectors planned for ITER must rely on many components to provide accurate feedback data and for control functions. Each component in the DMS is exposed to an elevated background magnetic field depending on its placement and proximity to the plasma chamber. A Helmholtz coil test stand that is operated at Oak Ridge National Laboratory was utilized to test the components in relevant background field levels to assess component performance. This paper details the test design and results for in-field component operation for a variety of components. This list includes the following components: two different network switches for camera connectivity, a VAT fast shutter valve intended to reduce the flow of SPI propellant gas into the torus, a solenoid control valve intended for use in the pellet formation process, pressure/vacuum switches to be used for feedback and control, a printed circuit board piezo pressure sensor to be used to measure breech pressure, and various relays for the high-voltage pulsed power supply used to drive the SPI propellant valve.

Disruption mitigation↗

Renormalization-group flow of the effective action of cosmological large-scale structures

Following an approach of Matarrese and Pietroni, we derive the functional renormalization group (RG) flow of the effective action of cosmological large-scale structures. Perturbative solutions of this RG flow equation are shown to be consistent with standard cosmological perturbation theory. Non-perturbative approximate solutions can be obtained by truncating the a priori infinite set of possible effective actions to a finite subspace. Using for the truncated effective action a form dictated by dissipative fluid dynamics, we derive RG flow equations for the scale dependence of the effective viscosity and sound velocity of non-interacting dark matter, and we solve them numerically. Physically, the effective viscosity and sound velocity account for the interactions of long-wavelength fluctuations with the spectrum of smaller-scale perturbations. We find that the RG flow exhibits an attractor behaviour in the IR that significantly reduces the dependence of the effective viscosity and sound velocity on the input values at the UV scale. This allows for a self-contained computation of matter and velocity power spectra for which the sensitivity to UV modes is under control.

79 ASTRONOMY AND ASTROPHYSICS↗

A Non-Exhaustive Search Algorithm to Identify Distribution Grid Operational Topology

Distribution grid, in general, is constructionally loopy but a radially operated network. Opening and closing of suitable tie-switches allow transition from one topology to another. Identifying the operational topology of a distribution system is essential for accurate control actions. This paper proposes a non-exhaustive search approach to detect the operational topology of the distribution feeder by estimating the switch statuses. In this work, a mixed-integer linear programming approach is proposed that finds the correct operational topology by identifying the system load demand and power flow variables that are closest to the corresponding measured values. The problem is constrained by distribution power flow and radial structure of the feeder. This formulation allows the inclusion of errors in power/line flow measurements making it more suitable for a practical distribution system. The proposed approach finds the correct operational topology without exhaustively searching for all possible topologies. We thoroughly validate the accuracy and effectiveness of the proposed approach in identifying correct operational topology using IEEE 123-node feeder with the help of numerous simulations studies. It is observed that the approach performs well even at very high percentages of load and flow measurement errors.

Missed detection ratio (MDR), Mixed-integer linear↗

A Data-Driven Approach to Dynamic Var Compensator Placement for Local Voltage Stabilization on Feeders with High PV Penetration

Distribution feeders with a high penetration of distributed photovoltaic (PV) systems can experience voltage variability caused by the changing load flow injections corresponding to the availability of the solar resource. The rapid, uncontrolled voltage range fluctuations can affect the system. Tap-changing voltage regulators, switched capacitors, and smart inverter functions have been used to stabilize voltage. However, in some cases, when these options are insufficient or unavailable, dedicated reactive power control devices such as dynamic var compensators (DVCs) can be used for local voltage stabilization. This paper introduces a statistical framework to characterize voltage variability and stabilization, proposes a data-driven approach to DVC placement, and presents the results of a planning study on a real feeder using real data.

Reiman, Andrew P.↗

System for NIS Forecasting Based on Ensembles Analysis

BMA-NIS is a package/library designed to be called by a script (e.g. Perl or Python). The software itself is written in the language of R. The software assists electric power delivery systems in planning resource availability and demand, based on historical data and current data variables. Net Interchange Schedule (NIS) is the algebraic sum of all energy scheduled to flow into or out of a balancing area during any interval. Accurate forecasts for NIS are important so that the Area Control Error (ACE) stays within an acceptable limit. To date, there are many approaches for forecasting NIS but all none of these are based on single models that can be sensitive to time of day and day of week effects.

Gosink, Luke↗

System for Testing Thermal Insulation of Pipes

An apparatus and method have been developed for measuring the rates of leakage of heat into pipes carrying liquids, the purpose of the measurements being to quantify the thermal performance of the insulation system. The apparatus is designed primarily for testing pipes used to carry cryogenic liquids, but can also be used for measuring the thermal performance of other insulated pipes or piping systems. The basic measurement principle is straightforward: The outer surface of the pipe insulation is maintained at a fixed warmer temperature. The interior of the pipe is maintained in a narrow fixed lower-temperature range by means of a regular liquid (e.g., water) that is pumped through the pipe at a known flow rate or a cryogenic liquid (e.g., nitrogen) that is saturated at atmospheric pressure and replenished until steady-state conditions are achieved. In the case of water or another liquid pumped through, the inlet and outlet temperatures are measured and heat-leak power is calculated as the mass flow rate of the liquid multiplied by the specific heat of the liquid multiplied by the inlet-to-outlet temperature rise of the liquid. In the case of liquid nitrogen or another low-temperature boiling liquid, the heat-leak power is calculated as the rate of boil-off multiplied by the latent heat of vaporization of the liquid. Then the thermal-insulation performance of the pipe system can be calculated as a function of the measured heat-leak power, the inner and outer boundary temperatures, and the dimensions of the pipe. The apparatus can test as many as three pipes simultaneously. The pipes can have inner diameters up to .15 cm and outer diameters up to .20 cm. The lengths of the pipes may vary; typical lengths are of the order of 18 m. Two thermal guard boxes . one for each end of the pipe(s) under test . are used to make the inlet and outlet fluid connections to the pipe(s) (see figure). The connections include bellows that accommodate thermal expansion and contraction of the pipes. The guard boxes and pipe(s) are positioned so that the pipe(s) slope upward from the upstream to the downstream end at an angle of at least 2 . The upward slope allows vapor bubbles to accumulate at the downstream end. The thermal guard boxes keep the ends of the pipes at the lower interior temperature to prevent spurious lengthwise leakage of heat into the pipes. It is important to prevent this spurious heat leakage because, if it were allowed to occur, it could contribute a large error in the measured heat-leak power. The upstream thermal guard box includes a heat exchanger through which liquid flowing into the pipe(s) is subcooled to the saturation temperature corresponding to the ambient pressure. Conversely, this heat exchanger can also be used to warm the flowing liquid to a desired fixed temperature. The apparatus includes a temperature control device that is placed around each pipe under test. Each device is operated under thermostatic control to maintain the outer surface of the pipe insulation at the specified test temperature. All measurements are recorded on a portable data-acquisition system.

Fesmire, James E.↗

Feasibility study for convertible engine torque converter

The feasibility study has shown that a dump/fill type torque converter has excellent potential for the convertible fan/shaft engine. The torque converter space requirement permits internal housing within the normal flow path of a turbofan engine at acceptable engine weight. The unit permits operating the engine in the turboshaft mode by decoupling the fan. To convert to turbofan mode, the torque converter overdrive capability bring the fan speed up to the power turbine speed to permit engagement of a mechanical lockup device when the shaft speed are synchronized. The conversion to turbofan mode can be made without drop of power turbine speed in less than 10 sec. Total thrust delivered to the aircraft by the proprotor, fan, and engine during tansient can be controlled to prevent loss of air speed or altitude. Heat rejection to the oil is low, and additional oil cooling capacity is not required. The turbofan engine aerodynamic design is basically uncompromised by convertibility and allows proper fan design for quiet and efficient cruise operation. Although the results of the feasibility study are exceedingly encouraging, it must be noted that they are based on extrapolation of limited existing data on torque converters. A component test program with three trial torque converter designs and concurrent computer modeling for fluid flow, stress, and dynamics, updated with test results from each unit, is recommended.

Source record↗

Resilient Cyber Infrastructure for the Minimum Wind Curtailment Remedial Control Scheme

Integration of Distributed Energy Resources (DER) has been significantly increasing in the electric power grid. One of the predominant renewable energy sources, wind energy, possess a significant challenge for grid operations, due to its intermittency, uncertainty and variability. In changing operating conditions with wind uncertainty, part of wind may need to be curtailed for the safe utilization of the transmission system. In order to minimize the wind power curtailment and to keep the power flow on a transmission line under limits, a cyber resilient Distributed Remedial Action Scheme (DRAS) is developed in this paper. The RAS is formulated as an optimization problem, considering the real power flow constraints of the transmission lines and given wind variability. In this paper, DRAS is developed to operate even with failures in the computing nodes to make it cyber-resilient. Distributed simplex algorithm is used for optimization in the distributed RAS. The DRAS is implemented in a decentralized platform called Resilient Information Architecture Platform for Smart Grid (RIAPS) to enable cyber resiliency of DRAS. The effectiveness of the proposed approach is validated through offline simulations of the New England 39 bus system and online simulations of IEEE 14 bus test system. In conclusion, a cyber physical test bed utilizing Real Time Digital Simulator (RTDS), Phasor Measurement Units (PMUs), and BeagleBones has been used for the online simulation and validation of the developed cyber-resilient RAS.

17 WIND ENERGY↗

Dynamic modeling and transient studies of a solid-sorbent adsorber for CO{sub 2} capture

The U.S. Department of Energy’s Carbon Capture Simulation Initiative (CCSI) is dedicated to accelerating the commercialization of carbon capture technologies from discovery to development, demonstration, and ultimately the widespread deployment to hundreds of power plants. In this multi-lab initiative in partnership with academic and industrial institutions, the National Energy Technology Laboratory (NETL) leads the development of a multi-scale modeling and simulation toolset for rapid evaluation and deployment of carbon capture systems. One element of the CCSI is focused on optimizing the operation and control of carbon capture systems since this can have a significant impact on the extent and the rate at which commercial-scale capture processes will be scaled-up, deployed, and used in the years to come. Capture processes must be capable of operating over a wide range of transient events, malfunctions, and disturbances, as well as under uncertainties. As part of this work, dynamic simulation and control models, methods, and tools are being developed for CO{sub 2} capture and compression processes and their integration with a baseline commercial-scale supercritical pulverized coal (SCPC) power plant. Solid-sorbent-based post-combustion capture technology was chosen as the first industry challenge problem for CCSI because significant work remains to define and optimize the reactors and processes needed for successful sorbent capture systems. Sorbents offer an advantage because they can reduce the regeneration energy associated with CO{sub 2} capture, thus reducing the parasitic load. In view of this, the current paper focuses on development of a dynamic model of a solid-sorbent CO{sub 2} adsorber-reactor and an analysis of its transient performance with respect to several typical process disturbances. A one-dimensional, non-isothermal, pressure-driven dynamic model of a two-stage bubbling fluidized bed (BFB) adsorber-reactor is developed in Aspen Custom Modeler (ACM). The BFB stages are of overflow-type configuration where the solids leave the stage by flowing over the overflow-weir. Each bed is divided into three regions, namely emulsion, bubble, and cloud-wake regions. In all three regions, the model considers mass and energy balances. Along with the models of the BFB stages, models of other associated hardware are developed and integrated in a single flowsheet. A valid pressure-flow network is developed and a lower-level control system is designed so that the overall CO{sub 2} capture can be maintained at a desired level in face of the typical disturbances. The dynamic model is used for studying the transient responses of a number of important process variables as a result of the disturbances that are typical of post-combustion CO{sub 2} capture processes.

20 FOSSIL-FUELED POWER PLANTS↗

Preliminary Scaling and controls Analysis of an FHR-HTSE System Idaho National Laboratory Summer 2013 Final Report

For new nuclear reactor system designs to be approved by regulatory agencies like the Nuclear Regulatory Commission (NRC), the details of system operation must be validated with respect to standards of safety, control, and output. A scaled experiment that replicates certain properties of the system can be used to validate compliance with regulatory standards, while avoiding the prohibitive cost and labor required to develop a fully functional prototype system; therefore, designing such an experiment is of special interest to current efforts to develop hybrid energy systems (HES) that integrate small modular reactors (SMRs), renewable energy systems, and industrial process applications such as hydrogen production and desalination. In addition, a scaled experiment can be an economical method of analyzing the interconnections between HES components and understanding the time constants associated between inter-component energy and information flows. This report discusses the results of a preliminary scaling analysis done for the primary loop of a 300 MWth Fluoride-Salt-Cooled High Temperature Reactor (FHR) that is coupled with a High-Temperature Steam Electrolysis system (HTSE), as well as the basic control logic that governs the primary components and the necessary hardware to achieve optimal functionality. The scaled facility will be a 1 MWth system that uses Dowtherm A as the simulant fluid for Flibe (the coolant of choice for the primary loop of molten salt reactors), and can validate the heat transfer and steady-state operational requirements of the 300 MWth prototype. The scaled facility matches the Prandtl and Reynolds numbers associated with steady-state operation of the FHR-HTSE’s primary loop without having to deal with very high temperatures, flow rates, or power inputs. This will allow the facility to run experiments that analyze various thermophysical and fluid-dynamic properties that characterize reactor operation, such as pressure drops, radial temperature distribution, heat exchanger conditions. The facility also has potential to integrate additional components of the prototype system, such as intermediate thermal-hydraulics loops, real-time grid-demand data, energy storage, and HTSE.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High rate reactive magnetron sputter deposition of Al-doped ZnO with unipolar pulsing and impedance control system

Al-doped ZnO (AZO) films were deposited on quartz glass substrates, unheated and heated to 200 deg. C, using reactive sputtering with a special feedback system of discharge impedance combined with midfrequency pulsing. A planar Zn-Al alloy target was connected to the switching unit, which was operated in a unipolar pulse mode. The oxidation of the target surface was precisely controlled by a feedback system for the entire O{sub 2} flow ratio including ''the transition region''. The deposition rate was about 10-20 times higher than that for films deposited by conventional sputtering using an oxide target. A deposition rate of AZO films of 390 nm/min with a resistivity of 3.8x10{sup -4} {Omega} cm and a transmittance in the visible region of 85% was obtained when the films were deposited on glass substrates heated to 200 deg. C with a discharge power of 4 kW.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary Scaling and controls Analysis of an FHR-HTSE System Idaho National Laboratory Summer 2013 Final Report

For new nuclear reactor system designs to be approved by regulatory agencies like the Nuclear Regulatory Commission (NRC), the details of system operation must be validated with respect to standards of safety, control, and output. A scaled experiment that replicates certain properties of the system can be used to validate compliance with regulatory standards, while avoiding the prohibitive cost and labor required to develop a fully functional prototype system; therefore, designing such an experiment is of special interest to current efforts to develop hybrid energy systems (HES) that integrate small modular reactors (SMRs), renewable energy systems, and industrial process applications such as hydrogen production and desalination. In addition, a scaled experiment can be an economical method of analyzing the interconnections between HES components and understanding the time constants associated between inter-component energy and information flows. This report discusses the results of a preliminary scaling analysis done for the primary loop of a 300 MWth Fluoride-Salt-Cooled High Temperature Reactor (FHR) that is coupled with a High-Temperature Steam Electrolysis system (HTSE), as well as the basic control logic that governs the primary components and the necessary hardware to achieve optimal functionality. The scaled facility will be a 1 MWth system that uses Dowtherm A as the simulant fluid for Flibe (the coolant of choice for the primary loop of molten salt reactors), and can validate the heat transfer and steady-state operational requirements of the 300 MWth prototype. The scaled facility matches the Prandtl and Reynolds numbers associated with steady-state operation of the FHR-HTSE’s primary loop without having to deal with very high temperatures, flow rates, or power inputs. This will allow the facility to run experiments that analyze various thermophysical and fluid-dynamic properties that characterize reactor operation, such as pressure drops, radial temperature distribution, heat exchanger conditions. The facility also has potential to integrate additional components of the prototype system, such as intermediate thermal-hydraulics loops, real-time grid-demand data, energy storage, and HTSE.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modelling wind power spatial-temporal correlation in multi-interval optimal power flow: A sparse correlation matrix approach

The significantly increasing deployment of wind power necessitates that system operation considers the spatial-temporal correlation of power forecast from different wind power plants. How to model this spatial-temporal correlation in the actual system dispatch is challenging. In this paper, a sparse correlation matrix is utilized to efficiently model the spatial-temporal correlation of wind power forecast in the generation dispatch model. A novel, adjustable, and distributionally-robust chance-constrained multi-interval optimal power flow (ADRCC-MIOPF) model is proposed to obtain reliable economic dispatch (ED) solutions. The spatial-temporal correlation of wind power plants power forecasts is represented by the sparse correlation covariance matrix obtained from historical, time series wind power forecast error data. The chance constraints in the ADRCC-MIOPF model are transformed into a set of second-order-cone (SOC) constraints in which an adjustable coefficient in the chance constraints controls the robustness of the ADRCC-MIOPF model to the wind power forecast errors distribution. Case studies performed on the PJM 5-bus system and IEEE 118-bus system verify the proposed method to improve the system security and reduce the cost especially under the high wind penetration levels. All the cases can be solved within several minutes for both the small and large cases which validates the efficiency of the proposed sparse matrix model. In addition, considering the spatial-temporal correlation of wind power forecast and the distributional robustness of wind power forecast error leads to a more reliable economic dispatch with lower system violations.

17 WIND ENERGY↗