Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Integrated Research Plan to Assess the Combined Effects of Space Radiation, Altered Gravity, and Isolation and Confinement on Crew Health and Performance: Problem Statement

Future crewed exploration missions to Mars could last up to three years and will expose astronauts to unprecedented environmental challenges. Challenges to the nervous system during these missions will include factors of: space radiation that can damage sensitive neurons in the central nervous system (CNS); isolation and confinement can affect cognition and behavior; and altered gravity that will change the astronauts’ perception of their environment and their spatial orientation, and will affect their coordination, balance, and locomotion. In the past, effects of spaceflight stressors have been characterized individually. However, long-term, simultaneous exposure to multiple stressors will produce a range of interrelated behavioral and biological effects that have the potential to adversely affect operationally relevant crew performance. These complex environmental challenges might interact synergistically and increase the overall risk to the health and performance of the astronaut. Therefore, NASA’s Human Research Program (HRP) has directed an integrated approach to characterize and mitigate the risk to the CNS from simultaneous exposure to these multiple spaceflight factors. The proposed research strategy focuses on systematically evaluating the relationships among three existing research risks associated with spaceflight: Risk of Acute (In-flight) and Late Central Nervous System Effects from Radiation (CNS), Risk of Adverse Cognitive or Behavioral Conditions and Psychiatric Disorders (BMed), and Risk of Impaired Control of Spacecraft/Associated Systems and Decreased Mobility Due to Vestibular/Sensorimotor Alterations Associated with Spaceflight (SM). NASA’s HRP approach is intended to identify the magnitude and types of interactions as they affect behavior, especially as it relates to operationally relevant performance (e.g., performance that depends on reaction time, procedural memory, etc.). In order to appropriately characterize this risk of multiple spaceflight environmental stressors, there is a recognition of the need to leverage research approaches using appropriate animal models and behavioral constructs. Very little has been documented on the combined effects of altered gravity, space radiation, and other psychological and cognitive stressors on the CNS. Preliminary evidence from rodents suggest that a combination of a minimum of exposures to even two of three stressors of: simulated space radiation, simulated microgravity, and simulated isolation and confinement, have produced different and more pronounced biological and performance effects than exposure to these same stressors individually. Structural and functional changes to the CNS of rodents exposed to transdisciplinary combined stressors indicate that important processes related to information processing are likely altered including impairment of exploratory and risk taking behaviors, as well as executive function including learning, memory, and cognitive flexibility — all of which may be linked to changes in related operational relevant performance. The fully integrated research plan outlines approaches to evaluate how combined, potentially synergistic, impacts of simultaneous exposures to spaceflight hazards will affect an astronaut’s CNS and their operationally relevant performance during future exploration missions, including missions to the Moon and Mars. The ultimate goals are to derive risk estimates for the combined, potentially synergistic, effects of the three major spaceflight hazards that will establish acceptable maximum decrement or change in a physiological or behavioral parameters during or after spaceflight, the acceptable limit of exposure to a spaceflight factor, and to evaluate strategies to mitigate any associated decrements in operationally relevant performance.

Steinberg, Susan L.↗

An investigation of signal performance enhancements achieved through innovative pixel design across several generations of indirect detection, active matrix, flat-panel arrays

Active matrix flat-panel imager (AMFPI) technology is being employed for an increasing variety of imaging applications. An important element in the adoption of this technology has been significant ongoing improvements in optical signal collection achieved through innovations in indirect detection array pixel design. Such improvements have a particularly beneficial effect on performance in applications involving low exposures and/or high spatial frequencies, where detective quantum efficiency is strongly reduced due to the relatively high level of additive electronic noise compared to signal levels of AMFPI devices. In this article, an examination of various signal properties, as determined through measurements and calculations related to novel array designs, is reported in the context of the evolution of AMFPI pixel design. For these studies, dark, optical, and radiation signal measurements were performed on prototype imagers incorporating a variety of increasingly sophisticated array designs, with pixel pitches ranging from 75 to 127 {mu}m. For each design, detailed measurements of fundamental pixel-level properties conducted under radiographic and fluoroscopic operating conditions are reported and the results are compared. A series of 127 {mu}m pitch arrays employing discrete photodiodes culminated in a novel design providing an optical fill factor of {approx}80% (thereby assuring improved x-ray sensitivity), and demonstrating low dark current, very low charge trapping and charge release, and a large range of linear signal response. In two of the designs having 75 and 90 {mu}m pitches, a novel continuous photodiode structure was found to provide fill factors that approach the theoretical maximum of 100%. Both sets of novel designs achieved large fill factors by employing architectures in which some, or all of the photodiode structure was elevated above the plane of the pixel addressing transistor. Generally, enhancement of the fill factor in either discrete or continuous photodiode arrays was observed to result in no degradation in MTF due to charge sharing between pixels. While the continuous designs exhibited relatively high levels of charge trapping and release, as well as shorter ranges of linearity, it is possible that these behaviors can be addressed through further refinements to pixel design. Both the continuous and the most recent discrete photodiode designs accommodate more sophisticated pixel circuitry than is present on conventional AMFPIs - such as a pixel clamp circuit, which is demonstrated to limit signal saturation under conditions corresponding to high exposures. It is anticipated that photodiode structures such as the ones reported in this study will enable the development of even more complex pixel circuitry, such as pixel-level amplifiers, that will lead to further significant improvements in imager performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling the Prodromal Effects and Performance Reduction of Astronauts from Exposure to Large Solar Particle Events

In space exploration outside the Earth's geomagnetic field, radiation exposure from solar particle events (SPE) presents a health concern for astronauts, that could impair their performance and result in possibility of failure of the mission. Acute risks are especially of concern during spacewalks on the lunar surface because of the rapid onset of SPE's and science goals that involve long distances to crew habitats. Thus assessing the potential of early radiation effect under such adverse conditions is of prime importance. Here we present a biologic based mathematical model which describes the dose and time-dependent early human responses to ionizing radiation. We examine the possible early effects on crew behind various shielding materials from exposure to some historical large SPEs on the lunar and Mars surfaces. The doses and dose rates were calculated using the BRYNTRN code (Kim, M.Y, Hu, X, and Cucinotta, F.A, Effect of Shielding Materials from SPEs on the Lunar and Mars Surface, AIAA Space 2005, paper number AIAA-2005-6653, Long Beach, CA, August 30-September 1, 2005) and the hazard of the early radiation effects and performance reduction were calculated using the RIPD code (Anno, G.H, McClellan, G.E., Dore, M.A, Protracted Radiation-Induced Performance Decrement, Volume 1 Model Development,1996, Defense Nuclear Agency: Alexandria VA). Based on model assumptions we show that exposure to these historical SPEs do cause early effects to crew members and impair their performance if effective shielding and medical countermeasure tactics are not provided. The calculations show multiple occurrence of large SPEs in a short period of time significantly increase the severity of early illness, however early death from failure of the hematopoietic system is very unlikely because of the dose-rate and dose heterogeneity of SPEs. Results from these types of calculations will be a guide in design of protection systems and medical response strategy for astronauts in case of exposure to high dose irradiation during future space missions.

Hu, S.↗

Navigation Prediction Performance During OSIRIS-REx Proximity Operations at (101955) Bennu

The OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification and Security–Regolith Explorer) Orbit Determination team performed covariance analyses prior to the commencement of proximity operations (ProxOps) at (101955) Bennu to determine the expected predicted trajectory performance in order to meet trajectory knowledge requirements throughout each phase of the mission. One of the primary requirements placed on the predicted trajectory performance was based on the performance during orbital phases leading up to the maneuver to initiate the Touch-and-Go (TAG) trajectory descent. Throughout ProxOps the nominal force models being used to predict the spacecraft trajectory were updated in an effort to improve the prediction performance. The most significant models that contributed to prediction performance were of solar radiation pressure, thermal reradiation of the spacecraft, predicted attitude errors, and desaturation maneuvers. Efforts were made throughout all of ProxOps to monitor, trend, predict, and update spacecraft modeling to improve the prediction performance. These efforts were vital to reduce the spacecraft knowledge errors necessary to achieve a TAG target smaller than pre-launch analysis allowed due to the rough terrain of Bennu. Increased precision in predicted trajectory errors allowed for refined uncertainties to be used for future phase planning throughout the mission. The navigation team successfully predicted the spacecraft trajectory throughout all of ProxOps achieving predicted trajectories errors less than originally analyzed.

Jason M. Leonard↗

Overview of the KSTAR experiments and future plan

The Korea Superconducting Tokamak Advanced Research (KSTAR) device has recently entered a new phase of operation following the installation of a tungsten mono-block divertor, providing a unique platform to investigate high-performance, long-pulse plasma scenarios for future reactors. The 2023–2024 experimental campaigns demonstrated significant progress in commissioning the tungsten divertor, developing plasma operation scenarios, and achieving real-time control. Comparative studies revealed increased core radiation losses and associated performance degradation relative to the carbon divertor environment. Alleviation strategies, such as optimized neutral beam injection timing, boron powder seeding, and impurity control through gas puffing, were shown to reduce tungsten accumulation and extend high-performance phases, including record H-mode operation exceeding 100 s. International collaboration enabled the first demonstration of high poloidal beta scenarios with an internal transport barrier on KSTAR. Advances in control included upgraded real-time resonant magnetic perturbation schemes and disruption forecasting. Furthermore, divertor detachment control using a new surrogate-model-based approach with real-time radiation imaging demonstrated active impurity and heat flux management. Supported by enhanced heating, current drive, and diagnostic systems, these achievements offer valuable insights into tungsten impurity behavior, transport physics, and control strategies for future reactors including ITER. Planned upgrades toward a full-tungsten wall and ITER-aligned real-time plasma control will further establish KSTAR as a leading experimental platform for developing operational scenarios required to achieve steady-state, burning plasma conditions.

KSTAR↗

Scientific Basis For Ultra-High Burn-Up Nuclear Fuels

A key issue on the path to nuclear energy becoming an essential component of the U.S. clean energy strategy is complete burn of the nuclear fuel. We propose research that will enable high-burn-up fuels by establishing the basic science for development and qualification of advanced nuclear fuel that will couple modern computational materials modeling, fabrication, and characterization capabilities with targeted performance-testing experiments using ion-beam facilities. This work will establish the scientific foundation and guide selection of the optimum fuel type for advanced reactor concepts. We expect to experimentally quantify the phase stability and kinetics of phase transformations, inter-diffusion, microstructural evolution, micromechanical properties, and the influence of severe radiation environments on fuel performance and, by the end of the project, develop a validated model for advanced nuclear energy materials under extreme conditions of radiation, temperature, and evolving chemistry. We will provide a science-based path forward to an optimized inert matrix fuel, while contributing to the development of a validated nuclear fuel database. We expect this project will further establish LLNL’s credibility in the nuclear energy community.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Prognostic Impact of Radiation Therapy to the Primary Tumor in Patients With Non-small Cell Lung Cancer and Oligometastasis at Diagnosis

Purpose: We investigated prognostic factors associated with survival in patients with non-small cell lung cancer (NSCLC) and oligometastatic disease at diagnosis, particularly the influence of local treatment to the primary site on prognosis. Methods and Materials: From January 2000 through June 2011, 78 consecutive patients with oligometastatic NSCLC (<5 metastases) at diagnosis underwent definitive chemoradiation therapy ({>=}45 Gy) to the primary site. Forty-four of these patients also received definitive local treatment for the oligometastases. Survival outcomes were estimated using the Kaplan-Meier method, and risk factors were identified by univariate and multivariate analyses. Results: Univariate Cox proportional hazard analysis revealed better overall survival (OS) for those patients who received at least 63 Gy of radiation to the primary site (P=.002), received definitive local treatment for oligometastasis (P=.041), had a Karnofsky performance status (KPS) score >80 (P=.007), had a gross tumor volume {<=}124 cm{sup 3} (P=.002), had adenocarcinoma histology (P=.002), or had no history of respiratory disease (P=.016). On multivariate analysis, radiation dose, performance status, and tumor volume retained significance (P=.004, P=.006, and P<.001, respectively). The radiation dose also maintained significance when patients with and without brain metastases were analyzed separately. Conclusions: Tumor volume, KPS, and receipt of at least 63 Gy to the primary tumor are associated with improved OS in patients with oligometastatic NSCLC at diagnosis. Our results suggest that a subset of such patients may benefit from definitive local therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Tolerant Antifuse FPGA

The total dose performance of the antifuse FPGA for space applications is summarized. Optimization of the radiation tolerance in the fabless model is the main theme. Mechanisms to explain the variation in different products are discussed.

Wang, Jih-Jong↗

The effects of dose, dose rate, and irradiation type and their equivalence on radiation-induced segregation in binary alloy systems via phase-field simulations

Radiation-induced segregation is a phenomenon commonly observed in many alloys which consists of the redistribution of elements (solute or interstitial impurities) under irradiation. The onset and development of radiation-induced segregation can only occur when a sufficient flux of defects is sustained and defect sinks are present. Irradiation dose, dose rate, and particle types all affect defect flux. In this work, we employ a phase-field model to examine the effects of dose, dose rate, and type of incident particles on radiation-induced segregation behavior in a model binary alloy. The phase-field model takes into account the formation and evolution of point defects as well as defect clusters, the diffusion and clustering of alloy species, the presence of additional extrinsic defect sinks in the form of dislocations, and two different methods of radiation-damage insertion, which are intended to simulate either light-ion/electron irradiation via Frenkel pairs or heavy-ion irradiation in the form of cascades. Our results show a dose-rate and particle-type dependence on the amount of solute segregation. We show that the material systems exposed to higher dose rates are less subjected to solute segregation at equivalent doses. We also show that such dose-rate-dependence behavior is due to a delay of the incubation dose at which radiation-induced segregation effectively starts. Particle type and the presence of dislocations can accentuate this behavior. Our model predictions correlate with many experimental observations made over the years on radiation-induced segregation providing credence to the simulation results. The methodology presented in this study allows for a first-order prediction of the dose rate at which proxy irradiation experiments could be performed to approximate radiation-induced segregation behaviors seen in targeted irradiation conditions.

36 MATERIALS SCIENCE↗

Method for controlling energy density for reliable pulsed laser deposition of thin films

We have established a methodology to stabilize the laser energy density on a target surface in pulsed laser deposition of thin films. To control the focused laser spot on a target, we have imaged a defined aperture in the beamline (so called image-focus) instead of focusing the beam on a target based on a simple “lens-focus.” To control the laser energy density on a target, we have introduced a continuously variable attenuator between the output of the laser and the imaged aperture to manipulate the energy to a desired level by running the laser in a “constant voltage” mode to eliminate changes in the lasers’ beam dimensions. This methodology leads to much better controllability/reproducibility for reliable pulsed laser deposition of high performance electronic thin films.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Tolerant, FPGA-Based SmallSat Computer System

The Radiation Tolerant, FPGA-based SmallSat Computer System (RadSat) computing platform exploits a commercial off-the-shelf (COTS) Field Programmable Gate Array (FPGA) with real-time partial reconfiguration to provide increased performance, power efficiency and radiation tolerance at a fraction of the cost of existing radiation hardened computing solutions. This technology is ideal for small spacecraft that require state-of-the-art on-board processing in harsh radiation environments but where using radiation hardened processors is cost prohibitive.

On-board processing for harsh radiation environmen↗

Photon Organ and Effective Dose Coefficients for Cranial and Caudal Irradiation Geometries - Paper 148

With the introduction of new recommendations of the ICRP in Publication 103 the methodology for determining the protection quantity effective dose has been modified. The modifications include changes in organ/tissue weighting factors as well as some changes in radiation weighting factors. Computations of protection dose coefficients now require the use of reference male and female voxel phantoms, see ICRP Publication 110. Computations of equivalent doses in organs and tissues are now performed in each phantom and the average is used to compute the effective dose. The latest set of external dose coefficients using the new reference phantoms and the latest guidance from the ICRP were performed by the ICRP DOCAL task group and reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Report 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT), and isotropic (ISO). For all geometries, except the ISO geometry, parallel beams are used to compute the dose coefficients. In this paper, the methodology of ICRP Publication 116 was used to compute dose coefficients for photons for irradiations of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace for personnel standing on contaminated surfaces or volumes and from overhead sources. In this work calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. Dose coefficients for caudal and cranial irradiation geometries have been calculated in accordance with ICRP Publication 103. The coefficients differ significantly from AP values for both organ and tissues of ICRP Publication 116, as would be expected. For workers in these scenarios organ and effective doses can differ significantly from AP values. For common photon energies (i.e. 100 keV to a few MeV) the AP effective dose overestimates the caudal and cranial values by about a factor of ten. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

New Radiation Tolerant LGAD for High Energy Physics

Low Gain Avalanche Detectors (LGADS) have recently been studied for applications in high energy physics. However, radiation hardness remains a problem. Here, we propose new LGAD process flow that allows for the creation of a very steep born profile in the multiapplication region, reducing the fractional acceptor removal and resulting performance degradation.

47 OTHER INSTRUMENTATION↗

Experimental and Computational Investigations of Phase Change Thermal Energy Storage Canisters

Two sets of experimental data are examined in this paper, ground and space experiments, for cylindrical canisters with thermal energy storage applications. A 2-D computational model was developed for unsteady heat transfer (conduction and radiation) with phase-change. The radiation heat transfer employed a finite volume method. The following was found in this study: (1) Ground Experiments: the convection heat transfer is equally important to that of the radiation heat transfer; radiation heat transfer in the liquid is found to be more significant than that in the void; including the radiation heat transfer in the liquid resulted in lower temperatures (about 15 K) and increased the melting time (about 10 min.); generally, most of the heat flow takes place in the radial direction. (2) Space Experiments: radiation heat transfer in the void is found to be more significant than that in the liquid (exactly the opposite to the Ground Experiments); accordingly, the location and size of the void affects the performance considerably; including the radiation heat transfer in the void resulted in lower temperatures (about 40 K).

Ibrahim, Mounir↗

Perceptions of Radiation Oncologists and Urologists on Sources and Type of Evidence to Inform Prostate Cancer Treatment Decisions

Purpose: To perform a national survey of radiation oncologists and urologists about the type of resources used and the level of evidence needed to change clinical practice in localized prostate cancer. Methods and Materials: From a random sample, 1422 physicians were mailed a survey assessing the types of information used and what level of evidence could alter their clinical practice in prostate cancer. Multivariable logistic regression models were used to identify differences in physician characteristics for each outcome. Results: Survey response rates were similar for radiation oncologists and urologists (44% vs 46%; P=.46). Specialty-specific journals represented the most commonly used resource for informing the clinical practice for radiation oncologists (65%) and urologists (70%). Relative to radiation oncologists, urologists were less likely to report utilizing top-tier medical journals (25% vs 39%; adjusted odds ratio [OR] 0.50; P=.01) or cancer journals (22% vs 51%; adjusted OR 0.50; P<.001) but more likely to rely on clinical guidelines (46% vs 38%; adjusted OR 1.6; P=.006). Both radiation oncologists and urologists most commonly reported large randomized, clinical trials as the level of evidence to change treatment recommendations for localized prostate cancer (85% vs 77%; P=.009). Conclusions: Both specialties rely on their own specialty-specific journals and view randomized, clinical trials as the level of evidence needed to change clinical practice. Our study provides a context on meaningful ways of disseminating evidence for localized prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GLOBAL STRUCTURE OF THREE DISTINCT ACCRETION FLOWS AND OUTFLOWS AROUND BLACK HOLES FROM TWO-DIMENSIONAL RADIATION-MAGNETOHYDRODYNAMIC SIMULATIONS

We present the detailed global structure of black hole accretion flows and outflows through newly performed two-dimensional radiation-magnetohydrodynamic simulations. By starting from a torus threaded with weak toroidal magnetic fields and by controlling the central density of the initial torus, {rho}{sub 0}, we can reproduce three distinct modes of accretion flow. In model A, which has the highest central density, an optically and geometrically thick supercritical accretion disk is created. The radiation force greatly exceeds the gravity above the disk surface, thereby driving a strong outflow (or jet). Because of mild beaming, the apparent (isotropic) photon luminosity is {approx}22L{sub E} (where L{sub E} is the Eddington luminosity) in the face-on view. Even higher apparent luminosity is feasible if we increase the flow density. In model B, which has moderate density, radiative cooling of the accretion flow is so efficient that a standard-type, cold, and geometrically thin disk is formed at radii greater than {approx}7 R{sub S} (where R{sub S} is the Schwarzschild radius), while the flow is radiatively inefficient otherwise. The magnetic-pressure-driven disk wind appears in this model. In model C, the density is too low for the flow to be radiatively efficient. The flow thus becomes radiatively inefficient accretion flow, which is geometrically thick and optically thin. The magnetic-pressure force, together with the gas-pressure force, drives outflows from the disk surface, and the flow releases its energy via jets rather than via radiation. Observational implications are briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Image Guided Radiation Therapy Using Synthetic Computed Tomography Images in Brain Cancer

Purpose: The development of synthetic computed tomography (CT) (synCT) derived from magnetic resonance (MR) images supports MR-only treatment planning. We evaluated the accuracy of synCT and synCT-generated digitally reconstructed radiographs (DRRs) relative to CT and determined their performance for image guided radiation therapy (IGRT). Methods and Materials: Magnetic resonance simulation (MR-SIM) and CT simulation (CT-SIM) images were acquired of an anthropomorphic skull phantom and 12 patient brain cancer cases. SynCTs were generated using fluid attenuation inversion recovery, ultrashort echo time, and Dixon data sets through a voxel-based weighted summation of 5 tissue classifications. The DRRs were generated from the phantom synCT, and geometric fidelity was assessed relative to CT-generated DRRs through bounding box and landmark analysis. An offline retrospective analysis was conducted to register cone beam CTs (n=34) to synCTs and CTs using automated rigid registration in the treatment planning system. Planar MV and KV images (n=37) were rigidly registered to synCT and CT DRRs using an in-house script. Planar and volumetric registration reproducibility was assessed and margin differences were characterized by the van Herk formalism. Results: Bounding box and landmark analysis of phantom synCT DRRs were within 1 mm of CT DRRs. Absolute planar registration shift differences ranged from 0.0 to 0.7 mm for phantom DRRs on all treatment platforms and from 0.0 to 0.4 mm for volumetric registrations. For patient planar registrations, the mean shift differences were 0.4 ± 0.5 mm (range, −0.6 to 1.6 mm), 0.0 ± 0.5 mm (range, −0.9 to 1.2 mm), and 0.1 ± 0.3 mm (range, −0.7 to 0.6 mm) for the superior-inferior (S-I), left-right (L-R), and anterior-posterior (A-P) axes, respectively. The mean shift differences in volumetric registrations were 0.6 ± 0.4 mm (range, −0.2 to 1.6 mm), 0.2 ± 0.4 mm (range, −0.3 to 1.2 mm), and 0.2 ± 0.3 mm (range, −0.2 to 1.2 mm) for the S-I, L-R, and A-P axes, respectively. The CT-SIM and synCT derived margins were <0.3 mm different. Conclusion: DRRs generated by synCT were in close agreement with CT-SIM. Planar and volumetric image registrations to synCT-derived targets were comparable with CT for phantom and patients. This validation is the next step toward MR-only planning for the brain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High performance aliphatic-heterocyclic benzyl-quaternary ammonium radiation-grafted anion-exchange membranes

Here, anion-exchange membranes (AEM) containing saturated-heterocyclic benzyl-quaternary ammonium (QA) groups synthesised by radiation-grafting onto poly(ethylene-co-tetrafluoroethylene) (ETFE) films are reported. The relative properties of these AEMs are compared with the benchmark radiation-grafted ETFE- g -poly(vinylbenzyltrimethylammonium) AEM. Two AEMs containing heterocyclic-QA head groups were down-selected with higher relative stabilities in aqueous KOH (1 mol dm –3 ) at 80 °C (compared to the benchmark): these 100 μm thick (fully hydrated) ETFE- g -poly(vinylbenzyl- N -methylpiperidinium)- and ETFE- g -poly(vinylbenzyl- N -methylpyrrolidinium)-based AEMs had as-synthesised ion-exchange capacities (IEC) of 1.64 and 1.66 mmol g –1 , respectively, which reduced to 1.36 mmol dm –3 (ca. 17–18% loss of IEC) after alkali ageing (the benchmark AEM showed 30% loss of IEC under the same conditions).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗