Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Model 2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Deriving brown carbon from multiwavelength absorption measurements: Method and application to AERONET and Aethalometer observations

The radiative impact of organic aerosols (OA) is a large source of uncertainty in estimating the global direct radiative effect (DRE) of aerosols. This radiative impact includes not only light scattering but also light absorption from a subclass of OA referred to as brown carbon (BrC). However the absorption properties of BrC are poorly understood leading to large uncertainties in modelling studies. To obtain observational constraints from measurements, a simple Absorption Ångström Exponent (AAE) method is often used to separate the contribution of BrC absorption from that of black carbon (BC). However, this attribution method is based on assumptions regarding the spectral dependence of BC that are often violated in the ambient atmosphere. Here we develop a new method that decreases the uncertainties associated with estimating BrC absorption. By applying this method to multi-wavelength absorption aerosol optical depth (AAOD) measurements at AERONET sites worldwide and surface aerosol absorption measurements at multiple ambient sites, we estimate that BrC globally contributes 6-40% of the absorption at 440nm. We find that the mass absorption coefficient of OA (OA-MAC) is positively correlated with BC/OA mass ratio. Based on the variability of BC properties and BC/OA emission ratio, we estimate a range of 0.05-1.2 m 2 /g for OA-MAC at 440nm. Using the combination of AERONET and OMI UV absorption observations we estimate that the AAE 388/440nm for BrC is generally ~4 world-wide, with a smaller value in Europe (< 2). Our analyses of two surface sites (Cape Cod, to the southeast of Boston, and the GoAmazon2014/5 T3 site, to the west of Manaus, Brazil) reveal no significant relationship between BrC absorptivity and photochemical aging in typical urban influenced conditions. However, the absorption of BrC measured during the biomass burning season near Manaus is found to decrease with photochemical aging with a lifetime of ~1 day. This lifetime is comparable to previous observations within a biomass burning plume but much slower than estimated from laboratory studies.

54 ENVIRONMENTAL SCIENCES↗

Data management strategy to improve global use of ocean acidification data and information

Ocean acidification (OA) refers to the general decrease in pH of the global ocean as a result of absorbing anthropogenic CO 2 emitted in the atmosphere since preindustrial times (sabine et al., 2004). There is, however, considerable variability in ocean acidification, and many careful measurements need to be made and compared in order to obtain scientifically valid information for the assessment of patterns, trends, and impacts over a range of spatial and temporal scales, and to understand the process involved. A single country or institution cannot undertaken measurements of worldwide coastal and open ocean OA changes; therefore, international cooperation is needed to achieve that goal. Here, the OA data that have been, and are being, collected represent a significant public investment. To this end, it is critically important that researchers (and others) around the world are easily able to find and use reliable OA information that range from observing data (from time-series moorings, process studies, and research cruises), to biological response experiments (e.g., mesocosm), data products, and model output.

54 ENVIRONMENTAL SCIENCES↗

Preliminary design overview and performance assessment of the ITER low-field side reflectometer

The design of the ITER low-field side reflectometer (LFSR) has matured to a complete end-to-end preliminary design. LFSR will supply three key plasma measurements: (1) electron density profile, (2) electron density fluctuations, and (3) poloidal rotation. Simultaneous measurements of the three quantities are enabled by an array of six monostatic antennas which inject from an equatorial port on the outboard side of the ITER vessel. Low-loss transmission lines, consisting of corrugated, overmoded waveguide and miter bends, transmit the 30–165 GHz, O- and X-mode signals to and from the ITER plasma. Integrated transmission-line components serve a range of purposes, such as protection from high-power stray radiofrequency radiation, accommodation of transmission-line displacement, and simultaneous measurement of reference and plasma phases during the discharge. Broadband transmission signals are realized by full-band microwave transceivers combined with quasi-optical multiplexing. A field-programmable gate array (FPGA) processor demodulates the profile reflectometer signals, enabling real-time density profile measurements for plasma control system feedback. A full-scale transmission line test facility provides an integrated environment to assess the performance of critical LFSR components. Theoretical modeling together with insertion loss measurements provide the basis for a comprehensive power budget, which accounts for transmitted output power, transmission-line losses, antenna coupling, and plasma effects. Results indicate that high signal-to-noise ratios are achievable with the current design. A synthetic reflectometer model, using real design parameters and baseline ITER profiles, has been developed to estimate the return signal. With evolving microwave and data acquisition technologies, full-band, ultrafast sweeps (<1 μs) will be realizable for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

When the universe expands too fast: relentless dark matter

Here we consider a modification to the standard cosmological history consisting of introducing a new species φ whose energy density red-shifts with the scale factor a like ρ φ ∝ a -(4+n) . For 0n>, such a red-shift is faster than radiation, hence the new species dominates the energy budget of the universe at early times while it is completely negligible at late times. If equality with the radiation energy density is achieved at low enough temperatures, dark matter can be produced as a thermal relic during the new cosmological phase. Dark matter freeze-out then occurs at higher temperatures compared to the standard case, implying that reproducing the observed abundance requires significantly larger annihilation rates. Here, we point out a completely new phenomenon, which we refer to as relentless dark matter: for large enough n, unlike the standard case where annihilation ends shortly after the departure from thermal equilibrium, dark matter particles keep annihilating long after leaving chemical equilibrium, with a significant depletion of the final relic abundance. Relentless annihilation occurs for n ≥ 2 and n ≥ 4 for s-wave and p-wave annihilation, respectively, and it thus occurs in well motivated scenarios such as a quintessence with a kination phase. We discuss a few microscopic realizations for the new cosmological component and highlight the phenomenological consequences of our calculations for dark matter searches.

79 ASTRONOMY AND ASTROPHYSICS↗

Neuronal changes and oxidative stress in adolescent rats after repeated exposure to mephedrone

Mephedrone is a new designer drug of abuse. We have investigated the neurochemical/enzymatic changes after mephedrone administration to adolescent rats (3 × 25 mg/kg, s.c. in a day, with a 2 h interval between doses, for two days) at high ambient temperature (26 ± 2 °C), a schedule that intends to model human recreational abuse. In addition, we have studied the effect of mephedrone in spatial learning and memory. The drug caused a transient decrease in weight gain. After the first dose, animals showed hypothermia but, after the subsequent doses, temperature raised over the values of saline-treated group. We observed the development of tolerance to these thermoregulatory effects of mephedrone. Mephedrone induced a reduction of the densities of dopamine (30% in the frontal cortex) and serotonin (40% in the frontal cortex and the hippocampus and 48% in the striatum) transporters without microgliosis. These deficits were also accompanied by a parallel decrease in the expression of tyrosine hydroxylase and tryptophan hydroxylase 2. These changes matched with a down-regulation of D{sub 2} dopamine receptors in the striatum. Mephedrone also induced an oxidative stress evidenced by an increase of lipid peroxidation in the frontal cortex, and accompanied by a rise in glutathione peroxidase levels in all studied brain areas. Drug-treated animals displayed an impairment of the reference memory in the Morris water maze one week beyond the cessation of drug exposure, while the spatial learning process seems to be preserved. These findings raise concerns about the neuronal long-term effects of mephedrone. - Highlights: • We studied the dopaminergic and serotonergic neurotoxicity of mephedrone in rats. • Mephedrone induced a transient hypothermia following sustained hyperthermia. • In a weekend consumption pattern, mephedrone induced selective neurotoxicity. • Mephedrone generated oxidative stress. • Mephedrone induced an impairment in memory function.

60 APPLIED LIFE SCIENCES↗

Development and characterization of the flight model spectrometer onboard LuSEE-Night

The Lunar Surface Electromagnetics Experiment - Night, LuSEE-Night, is a low-frequency radio astronomy experiment that will explore the cosmic Dark Ages signal on the radio-quiet far side of the Moon. Here, the LuSEE-Night carries a radio frequency spectrometer consisting of a set of antennas, analog and digital processing electronics, and will be launched by NASA’s Commercial Lunar Payload Services in 2025. The spectrometer is designed to observe the spectrum of the radio sky in the 0.5-50MHz band. The flight model (FM) of the four-channel spectrometer has been developed. The FM has been characterized for linearity, gain, noise, and their temperature dependence, confirming that the FM meets all the requirements for LuSEE-Night.

47 OTHER INSTRUMENTATION↗

SCALE 6.2 Lattice Physics Performance Assessment

The US Nuclear Regulatory Commission relies on the lattice physics analysis capabilities of the SCALE code system to perform confirmatory licensing analyses. Either SCALE lattice physics code—TRITON/NEWT or Polaris—can be used to generate cross section data used by the PARCS nodal core simulator for full-core neutronics calculations. This report presents an assessment of the accuracy of SCALE lattice physics codes for preparation of lattice physics data that are used to support simulator codes such as the NRC’s PARCS, for UO 2 -mixed oxide (MOX)/Zr fueled light water reactor (LWR) analyses. Due to the nature of lattice physics calculations, critical reactor experiment benchmarks cannot be modeled in explicit detail in a lattice physics code. However, this limitation does not mean that these measurement data are not usable for lattice physics studies. Therefore, either geometry approximations or axial buckling must be implemented to determine the critical water height. These modeling limitations have led to development of a three-phase assessment strategy. In the first phase, selected critical experiment benchmarks are modeled using the SCALE 3D continuous-energy (CE) Monte Carlo (MC) code KENO, which is the most rigorous neutron transport method available in SCALE, with no approximations in the spatial, angle, or energy treatments. Biases and statistical uncertainties in quantities of interest such as k eff and pin power distributions are determined by comparing CE KENO results to experimental data. This first phase in the accuracy assessment is to demonstrate and establish the use of CE KENO as a reference solution for the second phase. In the second phase, 14 numerical test suites are used to compare SCALE lattice physics calculations with CE KENO as a reference solution. In the third phase, SCALE lattice physics depletion calculations are performed, and the spent fuel isotopic results are compared with available radiochemical assay measurements. Isotopic measurement comparisons provide quantitative assessment of isotopic density distribution predictions with the depletion models in SCALE lattice physics codes. This report documents results for all test suites. The assessment was performed using standard production techniques unless otherwise noted. Both TRITON/NEWT and Polaris exhibited acceptable accuracy for most test cases. For the few test cases in which acceptable accuracy criteria were not met, further code and data development are planned. The computer codes used in this assessment are as follows: SCALE 6.2 rev19189 (pre-release of 6.2.1) was used for CE KENO, TRITON/NEWT and Polaris (PWR only) calculations; SCALE 6.2.2 was used for Polaris calculations to address several updates in support of support boiling water reactor (BWR) lattice geometries. For this work, there is no difference between SCALE 6.2.1 and SCALE 6.2.2 beyond the inclusion of the Polaris BWR analysis capability; The ENDF/B-VII.1 continuous energy and 252 group libraries deployed in SCALE 6.2 were generated with AMPX 6.2 that is distributed with SCALE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiphase computational fluid dynamics modeling of reacting flows in absorption columns for carbon capture

First-principles derived computational fluid dynamics (CFD) simulations have been proposed as a fundamental tool for investigating solvent-based CO 2 absorption in packed columns due to their ability to accurately represent the underlying nonlinear, multiscale dynamics. Numerous studies have previously utilized such CFD simulations to investigate hydrodynamics of columns with structured and random packings by assessing the key hydrodynamic metrics such as the interfacial and wetted areas. While mapping such metrics for different conditions is essential to the optimization of absorption columns, it is not sufficient, as the CO 2 capture rate depends also on the coupled, nonlinear dynamics from the underlying chemical reaction kinetics, thermodynamics, and heat-transfer rates. In this work, we present detailed CFD simulation results augmented by incorporating the effects of interfacial physical mass transfer of CO 2 , heat release from chemical reaction kinetics, and thermophysical property variations from resulting temperature gradients. We demonstrate the applicability of the proposed approach in numerically assessing the performance of packed columns by evaluating key hydrodynamic quantities, CO 2 absorption rates, and temperature rise in a reference column with packings that are structurally similar to the Sulzer Mellapak™ 250.Y packing, for different solvent inflow velocities and temperatures. Predictions from simulation results are found to be consistent with the trends in experimental observations from the literature, suggesting that the predictive capabilities of the simulation framework can be leveraged to guide the future development of absorber-column designs and optimized process flowsheets.

Absorption columns↗

Atomic-scale Imaging of PGM-free Catalyst Active Sites by 30 keV 4D-STEM

Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

Zachman, Michael↗

A review of geochemical–mechanical impacts in geological carbon storage reservoirs

Geological carbon storage (GCS) refers to the technology of capturing man-made carbon dioxide (CO 2 ) emissions, typically from stationary power sources, and storing such emissions in deep underground reservoirs. GCS is an approach being explored globally as a defense mechanism against climate change projections, although it is not without its critics. An important focus has been recently placed on understanding the coupling between rock–fluid geochemical alterations and mechanical changes for CO 2 storage schemes in saline aquifers. This article presents a review of the current state of knowledge regarding CO 2 -induced geochemical reactions in subsurface reservoirs, and their potential impact on mechanical properties and microseismic events at CO 2 storage sites. Therefore, this review focuses, in particular, on the current state of the art in fluid–rock interactions within the GCS context. Key issues to be addressed include geochemical reactions and the alteration of transport and mechanical properties. Specific review topics include the swelling of clays, the prediction of dissolution and precipitation reaction rates, CO 2 -induced changes in porosity and permeability, constitutive models of chemo–mechanical interactions in rock, and correlations between geochemical reactions and induced seismicity. The open questions in the field are emphasized, and new research needs are highlighted.

58 GEOSCIENCES↗

Wavelength- and irradiance-dependent changes in intracellular nitric oxide level

Photobiomodulation (PBM) refers to beneficial effects of low energy light absorption. Although there is a large and growing body of literature describing down-stream physiological benefits of PBM, there is limited understanding of the molecular mechanisms that initiate and mediate these effects at the level of photon absorption. At present, the leading hypothesis is that light absorption induces release of nitric oxide (NO) from the active site of cytochrome c oxidase (COX), allowing it to bind O 2 instead. This is believed to increase mitochondrial respiration, and result in greater overall health of the cell due to increased ATP production. Aim: Although NO itself is a powerful signaling molecule involved in a host of biological responses, less attention has been devoted to the mechanisms of NO release and subsequent effects on cell signaling. The purpose of this work is to investigate wavelength-specific effects on intracellular NO release in living cells. Approach: We have conducted in depth dosimetry analyses of NO production and function in an in vitro retinal model in response to low energy exposure to one or more wavelengths of laser light. Results: We found statistically significant wavelength-dependent elevations (10-30%) in intracellular NO levels following laser exposures at 447, 532, 635 or 808 nm. Sequential or simultaneous exposures to light at two different wavelengths enhanced the NO modulation up to 50% of unexposed controls. Additionally, the immediate increases in cellular NO levels were independent of the function of nitric oxide synthase, depended greatly on the substrate source of electrons entering the electron transport chain, and did not result in increased levels of cGMP. Conclusions: This study concludes the simple model of light-mediated release of NO from COX is unlikely to explain the wide variety of PBM effects reported in the literature. Our multi-wavelength method provides a novel tool for studying immediate and early mechanisms of PBM, as well as exploring intracellular NO signaling networks.

59 BASIC BIOLOGICAL SCIENCES↗

Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: Impact of radiation dose and reconstruction algorithms

Purpose: Efficient optimization of CT protocols demands a quantitative approach to predicting human observer performance on specific tasks at various scan and reconstruction settings. The goal of this work was to investigate how well a channelized Hotelling observer (CHO) can predict human observer performance on 2-alternative forced choice (2AFC) lesion-detection tasks at various dose levels and two different reconstruction algorithms: a filtered-backprojection (FBP) and an iterative reconstruction (IR) method. Methods: A 35 Multiplication-Sign 26 cm{sup 2} torso-shaped phantom filled with water was used to simulate an average-sized patient. Three rods with different diameters (small: 3 mm; medium: 5 mm; large: 9 mm) were placed in the center region of the phantom to simulate small, medium, and large lesions. The contrast relative to background was -15 HU at 120 kV. The phantom was scanned 100 times using automatic exposure control each at 60, 120, 240, 360, and 480 quality reference mAs on a 128-slice scanner. After removing the three rods, the water phantom was again scanned 100 times to provide signal-absent background images at the exact same locations. By extracting regions of interest around the three rods and on the signal-absent images, the authors generated 21 2AFC studies. Each 2AFC study had 100 trials, with each trial consisting of a signal-present image and a signal-absent image side-by-side in randomized order. In total, 2100 trials were presented to both the model and human observers. Four medical physicists acted as human observers. For the model observer, the authors used a CHO with Gabor channels, which involves six channel passbands, five orientations, and two phases, leading to a total of 60 channels. The performance predicted by the CHO was compared with that obtained by four medical physicists at each 2AFC study. Results: The human and model observers were highly correlated at each dose level for each lesion size for both FBP and IR. The Pearson's product-moment correlation coefficients were 0.986 [95% confidence interval (CI): 0.958-0.996] for FBP and 0.985 (95% CI: 0.863-0.998) for IR. Bland-Altman plots showed excellent agreement for all dose levels and lesions sizes with a mean absolute difference of 1.0%{+-} 1.1% for FBP and 2.1%{+-} 3.3% for IR. Conclusions: Human observer performance on a 2AFC lesion detection task in CT with a uniform background can be accurately predicted by a CHO model observer at different radiation dose levels and for both FBP and IR methods.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-08: Uncertainties in Kinetic Modeling of Shortened Dynamic 18F-FMISO PET Due to Image Noise

Purpose: To assess uncertainties in voxel-wise kinetic modeling (KM) of dynamic 18F-FMISO PET (dPET) due to image noise for different lengths of dPET acquisitions. Methods: 12 tumor time activity curves (TACs) deduced from 6 head and neck cancer patient dPET datasets (45min dPET + 10min frames at ∼95min and ∼160min respectively) were modeled using an irreversible two-tissue compartment model to estimate kinetic rate constants (KRCs) k3, vB, K1, and K1/k2 (reference standard). For each modeled TAC, 1000 noisy TACs were simulated by adding Gaussian noise with standard deviation equivalent to that observed on a voxel level in GE DSTE PET-CT. KM was conducted for each set of noisy TACs using (i) full dataset (170min), and repeated using (ii) 105min and (iii) 45min shortened subsets, with an input function that was image-derived from the dPET dataset of matching length. Absolute value of percent difference between KRCs from noisy TACs as estimated from either of 3 datasets and reference standard KRCs was used to represent bias. Results: For all KRCs, bias was higher for shortened datasets. For k3, bias was lower when actual k3 was higher: from 7%±5% (170min), 9%±7% (105min), and 14%±11% (45min) (actual k3=0.0098), to 32%±25% (170min), 45%±34% (95min), and 79%±48% (45min) (actual k3=0.0008). Similar relationship was observed for vB, with bias being between ∼7% (actual vB=0.28) and ∼26–34% (actual vB=0.08). For K1 [K1/k2], bias was ∼6–10% [∼2–3%] (dependence on actual value of K1 [K1/k2] was not observed). Conclusion: Uncertainties in voxel-wise KM of shortened 18F-FMISO dPET due to image noisy only are larger for shorter acquisitions and, for k3 [vB], the bias was found to be inversely correlated with the actual values of k3 [vB]. Using 45min subset, k3, vB, K1, and K1/k2 could be estimated to within ∼15–80%, ∼10–35%, ∼10%, and ∼3%, respectively.

60 APPLIED LIFE SCIENCES↗

Size-resolved aerosol emission factors and new particle formation/growth activity occurring in Mexico City during the MILAGRO 2006 Campaign

Measurements of the aerosol size distribution from 11 nm to 2.5 microns were made in Mexico City in March 2006, during the MILAGRO (Megacity Initiative: Local and Global Research Observations) field campaign. Observations at the urban supersite, referred to as T0, could often be characterized by morning conditions with high particle mass concentrations, low mixing heights, and highly correlated particle number and CO{sub 2} concentrations, indicative that particle number is controlled by primary emissions. Average size-resolved and total number- and volume-based emission factors for combustion sources impacting T0 have been determined using a comparison of peak sizes in particle number and CO{sub 2} concentration. Peaks are determined by subtracting the measured concentration from a calculated baseline concentration time series. The number emission and volume emission factors for particles from 11 nm to 494 nm are 1.56 x 10{sup 15} particles, and 9.48 x 10{sup 11} cubic microns per kg of carbon, respectively. The uncertainty of the number emission factor is approximately plus or minus 50 %. The mode of the number emission factor was between 25 and 32 nm, while the mode of the volume factor was between 0.25 and 0.32 microns. These emission factors are reported as log normal model parameters and are compared with multiple emission factors from the literature. In Mexico City in the afternoon, the CO{sub 2} concentration drops during ventilation of the polluted layer, and the coupling between CO{sub 2} and particle number breaks down, especially during new particle formation events when particle number is no longer controlled by primary emissions. Using measurements of particle number and CO{sub 2} taken aboard the NASA DC-8, the determined primary emission factor was applied to the Mexico City Metropolitan Area (MCMA) plume to quantify the degree of secondary particle formation in the plume; the primary emission factor accounts for less than 50 % of the total particle number and the surplus particle count is not correlated with photochemical age. Primary particle volume and number in the size range 0.1-2 {micro}m are similarly too low to explain the observed volume distribution. Contrary to the case for number, the apparent secondary volume increases with photochemical age. The size distribution of the apparent increase, with a mode at {approx}250 nm, is reported.

54 ENVIRONMENTAL SCIENCES↗

Chapmanite [Fe 2 Sb(Si 2 O 5 )O 3 (OH)]: thermodynamic properties and formation in low-temperature environments

Abstract. of synthetic Sb 2 O 5 , MgSb 2 O 6 (analogue of the mineral byströmite), Mg[Sb(OH) 6 ] 2 ∙6H 2 O (brandholzite), and natural chapmanite [(Fe 1.88 Al 0.12 )Sb(Si 2 O 5 )O 3 (OH)]. Enthalpies of reactions, including formation enthalpies, were evaluated using reference compounds Sb, Sb 2 O 3 , Sb 2 O 5 , and other phases, with high-temperature oxide melt solution calorimetry in lead borate and sodium molybdate solvents. Heat capacity and entropy were determined by relaxation and differential scanning calorimetry. The best set of Δ f H o (kJ mol -1 ) and S o (J mol -1 K -1 ) is byströmite -1733.0±3.6, 139.3±1.0; brandholzite -5243.1±3.6, 571.0±4.0; and chapmanite -3164.9±4.7, 305.1±2.1. The data for chapmanite give Δ f G o of -2973.6±4.7 kJ mol -1 and log K=-17.10 for the dissolution reaction (Fe 1.88 Al 0.12 )Sb(Si 2 O 5 )O 3 (OH) + 6H + → 1.88Fe 3+ + 0.12Al 3+ + 2SiO$_2^0$ + Sb(OH)$_3^0$ + 2H 2 O. Analysis of the data showed that chapmanite is finely balanced in terms of its stability with schafarzikite (FeSb 2 O 4 ) and tripuhyite (FeSbO 4 ) under a specific, narrow range of conditions when both aqueous Fe(III) and Sb(III) are abundant. In such a model, chapmanite is metastable by a narrow margin but could be stabilized by high SiO$_2^0$(aq) activities. Natural assemblages of chapmanite commonly contain abundant amorphous silica, suggesting that this mechanism may be indeed responsible for the formation of chapmanite. Chapmanite probably forms during low-temperature hydrothermal overprint of pre-existing Sb ores under moderately reducing conditions; the slightly elevated temperatures may help to overcome the kinetic barrier for its crystallization. During weathering, sheet silicates may adsorb Sb 3+ in tridentate hexanuclear fashion, thus exposing their chapmanite-like surfaces to the surrounding aqueous environment. Formation of chapmanite, as many other sheet silicates, under ambient conditions, is unlikely.

58 GEOSCIENCES↗

TH-AB-201-11: Small-Field Beam Quality Corrections and Their Clinical Impact for Flattened and Unflattened Fields of the TrueBeam

Purpose: To determine small-field beam quality correction factors for several detectors used with flattened and unflattened beams of the Varian TrueBeam accelerator, and to quantify the clinical impact of these corrections through a treatment planning study. Methods: Small-field beam quality correction factors were measured and simulated in EGSnrc for several microchambers and diodes. The Exradin W1 plastic scintillation detector was used as a reference for the measured results, and its response was validated using alanine measurements traceable to a primary standard. Symmetric, jaw-defined field sizes ranging from 6 mm to 10 cm were used. Twelve hypofractionated clinical cases were then recalculated and/or reoptimized using beam models that were modified based on the resulting output factors. Three-dimensional dose distributions and cumulative dose-volume-histogram plots were compared between the models. The impact of these measurements on the flattening-filter-scatter-source (FFSS) model, and its subsequent effect on treatment plans, was also investigated. Results: The diodes exhibited over-response in small fields, whereas the microchambers tended to under-respond as field size decreased. Field-size-dependent effects were less significant for the flattening-filter-free beams (i.e., corrections were closer to unity) than for flattened fields of the same size. Recalculated and reoptimized plans displayed varying levels of deviation from the original dose distributions, with larger discrepancies at effective jaw settings of 3×3 cm{sup 2} or smaller. Dose distributions calculated using uncorrected microchamber output factors and/or modified FFSS showed large discrepancies in the low-dose regions, which manifested as DVH changes for the organs at risk (OAR). Conclusion: Field-size-dependent beam quality corrections were measured and simulated for ionization chambers and diodes typically used in small fields. Plans calculated with models based on these measured data showed dosimetric deviations mainly out of field, which affected OAR dose metrics. Accordingly, these beam quality corrections should be accounted for during commissioning to ensure greater treatment planning accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

DESI Emission-line Galaxies: Unveiling the Diversity of [O II ] Profiles and Its Links to Star Formation and Morphology

We study the [O II ] profiles of emission-line galaxies (ELGs) from the Early Data Release of the Dark Energy Spectroscopic Instrument (DESI). To this end, we decompose and classify the shape of [O II ] profiles with the first two eigenspectra derived from principal component analysis. Our results show that DESI ELGs have diverse line profiles, which can be categorized into three main types: (1) narrow lines with a median width of ∼50 km s −1 , (2) broad lines with a median width of ∼80 km s −1 , and (3) two redshift systems with a median velocity separation of ∼150 km s −1 , i.e., double-peak galaxies. To investigate the connections between the line profiles and galaxy properties, we utilize the information from the COSMOS data set and compare the properties of ELGs, including star formation rate (SFR) and galaxy morphology, with the average properties of reference star-forming galaxies with similar stellar mass, sizes, and redshifts. Our findings show that, on average, DESI ELGs have a higher SFR and more asymmetrical/disturbed morphology than the reference galaxies. Moreover, we uncover a relationship between the line profiles, the excess SFR, and the excess asymmetry parameter, showing that DESI ELGs with broader [O II ] line profiles have more disturbed morphology and higher SFR than the reference star-forming galaxies. Finally, we discuss possible physical mechanisms giving rise to the observed relationship and the implications of our findings on the galaxy clustering measurements, including the halo occupation distribution modeling of DESI ELGs and the observed excess velocity dispersion of the satellite ELGs.

79 ASTRONOMY AND ASTROPHYSICS↗

A Proposal for the Maximum KIC for Use in ASME Code Flaw and Fracture Toughness Evaluations

Nonmandatory Appendices A [1] and G [2] of Section XI of the ASME Code use the KIc curve (indexed to the material reference transition temperature, RTNDT) in reactor pressure vessel (RPV) flaw evaluations, and for the purpose of establishing RPV pressure-temperature (P-T) limits. Neither of these appendices places an upper-limit on the KIc value that may be used in these assessments. Over the years, it has often been suggested by some of the members of the ASME Section XI Code committees that are responsible for maintaining Appendices A and G that there is a practical upper limit of 200 ksi in (220 MPa m) [4]. This upper limit is not well recognized by all users of the ASME Code, is not explicitly documented within the Code itself, and the one source known to the authors where it is defended [4] relies on data that is either in error, or is less than 220 MPa m. However, as part of the NRC/industry pressurized thermal shock (PTS) re-evaluation effort, empirical models were developed that propose common temperature dependencies for all ferritic steels operating on the upper shelf. These models relate the fracture toughness properties in the transition regime to those on the upper shelf and, combined with data for a wide variety of RPV steels and welds on which they are based, suggest that the practical upper limit of 220 MPa m exceeds the upper shelf fracture toughness of most RPV steels by a considerable amount, especially for irradiated steels. In this paper, available models and data are used to propose upper bound limits of applicability on the KIc curve for use in ASME Code, Section XI, Nonmandatory Appendices A and G evaluations that are consistent with available data for RPV steels.

36 MATERIALS SCIENCE↗