Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL PROCESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

GUN1 interacts with MORF2 to regulate plastid RNA editing during retrograde signaling

During development or under stress, chloroplasts generate signals that regulate the expression of a large number of nuclear genes, a process called retrograde signaling. GENOMES UNCOUPLED 1 (GUN1) is an important regulator of this pathway. In this study, we have discovered an unexpected role for GUN1 in plastid RNA editing, as gun1 mutations affect RNA-editing efficiency at multiple sites in plastids during retrograde signaling. GUN1 plays a direct role in RNA editing by physically interacting with MULTIPLE ORGANELLAR RNA EDITING FACTOR 2 (MORF2). MORF2 overexpression causes widespread RNA-editing changes and a strong genomes uncoupled ( gun ) molecular phenotype similar to gun1 . MORF2 further interacts with RNA-editing site-specificity factors: ORGANELLE TRANSCRIPT PROCESSING 81 (OTP81), ORGANELLE TRANSCRIPT PROCESSING 84 (OTP84), and YELLOW SEEDLINGS 1 (YS1). We further show that otp81 , otp84 , and ys1 single mutants each exhibit a very weak gun phenotype, but combining the three mutations enhances the phenotype. Our study uncovers a role for GUN1 in the regulation of RNA-editing efficiency in damaged chloroplasts and suggests that MORF2 is involved in retrograde signaling.

59 BASIC BIOLOGICAL SCIENCES↗

(Doublon) Benchmarking of Different Inverse Point Kinetics Implementations for an Autocorrected Reactimeter Algorithm

In November 2017, the Transient Reactor Test Facility returned to operation. Since that time, many transient test series have been completed, such as the Transient Heatsink Overpower Response capsule (THOR), the Transient Water Irradiation System for TREAT (TWIST), and Sirius. Each has provided valuable data for materials performance and reactor safety that can be applied in future designs. During each experimental series, detector count rates provided important information on the core behavior during transients. However, a limitation of these data is that variations in the neutron distribution during experiments can cause errors when attempting to infer reactivity evolution from detector signals. Neutron physics codes can be used to compute the flux shape variations. However, this is a poor solution when the experimental data is used for code verification, validation and uncertainty quantification. Indeed, if the output of the code is used both as a reference and to correct what the reference is compared to, the circular dependency limits the quality of the verification, validation and uncertainty quantification approach. To overcome this problem, the autocorrected reactimeter algorithm (ACRA) has been developed. This approach infers a time-dependent reactivity evolution by testing different spatial corrections and selecting the one that minimizes reactivity variations when the core is in a frozen configuration (i.e., when there is no variation in parameters affecting reactivity). However, the scope of this method was limited to transients where there were negligible thermal feedback. Indeed, the core is never in a frozen configuration when the fuel temperature varies during the whole transient. This is our motivation for developing an improved version of the ACRA that does not require frozen configurations. To develop this new algorithm, we need a precise and unbiased implementation of the inverse point kinetic equations (IPKEs) as any error in the reactivity evaluation will be propagated into the choice of the optimal spatial correction. Indeed, the previous reactimeter algorithm would use approximations, such as a negligible flux amplitude derivative, to focus on rapidity. For the numerical validation of ACRA, we aim at absolute error under for reactivity derived from signals similar to the one of this study. In this summary, we test eight different IPKE implementations. Each will process a mockup signal built for this study, similar to those that the future ACRA will process. Each reactivity output will be compared to the reference reactivity that has been used to generate the mockup signal. The implementation minimizing the difference with the reference reactivity will be used in the development of a new ACRA formulation.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise nanosecond time resolved infrared radiometry measurements of laser induced silicon phase change and melting front propagation

Nanosecond laser melting of silicon was investigated by infrared (IR) radiometry and time resolved reflectivity (TRR) methods. IR radiometry revealed interesting signal evolutions and their qualitative changes during different stages of the melting process. The observed signals represent melting front propagation, liquid phase overheating, and melt duration. Comparison of IR and TRR methods is shown. The physical origin of the IR signal shapes is discussed in detail.

36 MATERIALS SCIENCE↗

High-Power High-Speed Schottky Photodiodes for Analog Fiber-Optic Microwave Signal Transmission Lines

Design and manufacturing technology of high-power microwave Schottky photodiodes with microstripe leads have been developed based on an InAlAs/InGaAs heterostructure. The operating frequency of photodiodes with a mesa diameter of 15 μm is above 25 GHz and a maximum output microwave power at 20 GHz exceeds 50 mW, which allows these photodiodes to be employed in analog fiber-optic microwave signal transmission lines, as well as for the microwave signal generation and processing by optical methods in remote sensing and measuring microwave technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pickless event detection and location: The waveform correlation event detection system (WCEDS) revisited

The standard paradigm for seismic event monitoring breaks the event detection problem down into a series of processing stages that can be categorized at the highest level into station-level processing and network-level processing algorithms (e.g., Le Bras and Wuster (2002)). At the station-level, waveforms are typically processed to detect signals and identify phases, which may subsequently be updated based on network processing. At the network-level, phase picks are associated to form events, which are subsequently located. Furthermore, waveforms are typically directly exploited only at the station-level, while network-level operations rely on earth models to associate and locate the events that generated the phase picks.

58 GEOSCIENCES↗

Polarization Amplitude-Based Method of Determining the Bearing and Roll Angles of an Object in Motion from Orthogonal Circularly Polarized Signals of a Radio Beacon

The possibility of determining the bearing and roll angles of an object in motion is investigated based on orthogonal left- and right-hand circularly polarized signals simultaneously radiated by a radio beacon from two points with the known coordinates spatially spaced in the horizontal plane. The bearing and roll angles are determined onboard the object in motion using a two-channel receiving system based on polarization amplitude-based processing of resultant vector signals received in a linear polarization basis.

36 MATERIALS SCIENCE↗

Stable electrospray signal on a microfabricated glass chip with three-dimensional open edge and tiered depth geometries

This paper presents the microfabrication and performance of a three-dimensional electrospray ionization (ESI) emitter tip made from glass, which achieves stable current signals important for chemical analysis. Our novel microfabrication process and custom-built signal conditioning hardware provides the advantage of providing accurate features and steady signals. The fabrication process relies on standard microfabrication techniques (i.e., deposition, photolithography, and wet etching). This fabrication method involves the novel application of two layers of positive and negative photoresists in addition to Parafilm® wax tape. Open edge and tiered depth details were successfully created from a multilayer planar mask. This is a benefit for integrated miniaturized and microfluidic systems that often require micro features for their functionality but relatively large millimeter size features for their physical periphery. We demonstrate the fundamental performance of electrospray with this microfluidic chip. The emitter tip was fixed on a linear axis stage with high resolution (10 μm) to finely control the tip distance from a metal counter electrode plate. Further, a custom printed circuit board system was built to safely control four voltages applied to the microchip ports from a single high voltage power supply. To readily form the electrospray, non-aqueous solvents were used for their low viscosity and a constant voltage of +2.7 kV was applied to the sheath electrospray microchannel. The liquid being sprayed was 80/20 (v/v) methanol/acetonitrile with 0.1% acetic acid in the sheath microchannel and with ammonium acetate (10–40 mM) in its remaining microchannels. The electrospray signal was measured in response to varying the distance (1.4 to 1.6mm) between the electrospray emitter tip and a metal counter electrode plate in addition to the varying concentration of the background electrolyte, ammonium acetate. Stable and repeatable electrospray signal showed linear relationships with emitter tip distance and concentration (r 2 ≥ 0.95).

42 ENGINEERING↗

Progress in the development of the neutron flux monitoring system of the French GEN-IV SFR: simulations and experimental validations [ANIMMA--2015-IO-392]

France has a long experience of about 50 years in designing, building and operating sodium-cooled fast reactors (SFR) such as RAPSODIE, PHENIX and SUPER PHENIX. Fast reactors feature the double capability of reducing nuclear waste and saving nuclear energy resources by burning actinides. Since this reactor type is one of those selected by the Generation IV International Forum, the French government asked, in the year 2006, CEA, namely the French Alternative Energies and Atomic Energy Commission, to lead the development of an innovative GEN-IV nuclear- fission power demonstrator. The major objective is to improve the safety and availability of an SFR. The neutron flux monitoring (NFM) system of any reactor must, in any situation, permit both reactivity control and power level monitoring from startup to full power. It also has to monitor possible changes in neutron flux distribution within the core region in order to prevent any local melting accident. The neutron detectors will have to be installed inside the reactor vessel because locations outside the vessel will suffer from severe disadvantages; radially the neutron shield that is also contained in the reactor vessel will cause unacceptable losses in neutron flux; below the core the presence of a core-catcher prevents from inserting neutron guides; and above the core the distance is too large to obtain decent neutron signals outside the vessel. Another important point is to limit the number of detectors placed in the vessel in order to alleviate their installation into the vessel. In this paper, we show that the architecture of the NFM system will rely on high-temperature fission chambers (HTFC) featuring wide-range flux monitoring capability. The definition of such a system is presented and the justifications of technological options are brought with the use of simulation and experimental results. Firstly, neutron-transport calculations allow us to propose two in-vessel regions, namely the above-core and under-core structures. We verify that they comply with the main objective, that is the neutron power and flux distribution monitoring. HTFC placed in these two regions can detect an inadvertent control rod withdrawal that is a postulated initiating event for safety demonstration. Secondly, we show that the HTFC reliability is enhanced thanks to a more robust physical design and the fact that it has been justified that the mineral insulation is insensitive to any increase in temperature. Indeed, the HTFC insulation is subject to partial discharges at high temperature when the electric field between their electrodes is greater than about 200 V/mm or so. These discharges give rise to signals similar to the neutron pulses generated by a fission chamber itself, which may bias the HTFC count rate at start-up only. However, as displayed in Figure 1, we have experimentally verified that one can discriminate neutron pulses from partial discharges using online estimation of pulse width. Thirdly, we propose to estimate the count rate of a HTFC using the third order cumulant of its signal that is described by a filtered Poisson process. For such a statistic process, it is known that any cumulant, also called cumulative moment, is proportional to the process intensity that is here the count rate of a fission chamber. One recalls that the so-called Campbelling mode of such a detector is actually based on the signal variance, which is the second-order cumulant as well. The use of this extended Campbelling mode based on the third-order cumulant will permit to ensure the HTFC response linearity over the entire neutron flux range using a signal processing technique that is simple enough to satisfy design constraints on electric devices important for nuclear safety. We also show that this technique, named high order Campbelling method (HOC), is significantly more robust than another technique based on the change in the HTFC filling gas, which consists in adding a few percent of nitrogen. Finally, we also present an experimental campaign devoted to the required calibration process of the so-called HOC method. The Campbelling results show a good agreement with the simple pulse counting estimation at low count rates. It is also shown that the HOC technique provides a linear estimation of the count rates at higher power levels as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

JSATS Detector Field Manual

The Juvenile Salmon Acoustic Telemetry System (JSATS) Detector is a software and hardware system that captures JSATS Acoustic Micro Transmitter (AMT) signals. The system uses hydrophones to capture acoustic signals in the water. This analog signal is then amplified and processed by the Analog to Digital Converter (ADC) and Digital Signal Processor (DSP) board in the computer. This board digitizes and processes the acoustic signal to determine if a possible JSATS tag is present. With this detection, the data will be saved to the computer for further analysis. This document details the features and functionality of the JSATS Detector software. The document covers how to install the software, setup and run the detector software. The document will also go over the raw binary waveform file format and CSV files containing RMS values

47 OTHER INSTRUMENTATION↗

Semiconductor power device including wire or ribbon bonds over device active region

A semiconductor power device including a base plate; an input lead; an output lead; a field effect transistor (FET) power die disposed over the base plate, wherein the FET power die includes a set of source fingers, a set of drain fingers, and a set of gate fingers disposed directly over an active region, wherein the gate fingers are configured to receive an input signal from the input lead, and wherein the FET power die is configured to process the input signal to generate an output signal at the drain fingers for routing to the output lead; and electrical conductors (wirebonds or ribbons) bonded to the source and/or drain directly over the active region of the FET power die. The electrical conductors produce additional thermal paths between the active region and the base plate for thermal management of the FET power die.

42 ENGINEERING↗

Measurement of the WW+WZ Production Cross Section Using the Lepton+Jets Final State at CDF II

We report two complementary measurements of the diboson (WW + WZ) cross section in the final state consisting of an electron or muon, missing transverse energy, and jets, performed using p{bar p} collision data at {radical}s = 1.96 TeV collected by the Collider Detector at Fermilab. The first method uses the dijet invariant mass distribution while the second method uses more of the kinematic information in the event through matrix-element calculations of the signal and background processes and has a higher sensitivity. The result from the second method has a signal significance of 5.4{sigma} and is the first observation of WW + WZ production using this signature. Combining the results from both methods gives {sigma}{sub WW+WZ} = 16.0 {+-} 3.3 pb, in agreement with the standard model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An integrated wire harp and readout electronics inside vacuum

A wire harp is a well known instrument used in ion beam profile measurement and beam diagnostics. Till date, for beam instrumentation, the harp is placed inside the vacuum chamber or beam line in direct exposure to the beam profile to be measured, whereas the related readout electronics is placed outside somewhere at a convenient place. Here, a harp has been developed along with the readout electronics as an integrated part of it and both were placed inside the beam line vacuum (order of 10{sup −7} Torr) to make the system much simpler, easy to operate, and measure small beam current more accurately. The entire signal conversion and processing is done inside the vacuum unlike other systems; hence, the electronics is kept inside. This results in a lesser number (only 4 pin) of electrical connections (feedthrough) including power which otherwise would have required 32 feedthrough pins only for signal readout for a 13 × 13 (X × Y) channel harp. This paper describes a completely new approach to the design of a conventional beam harp widely used for beam instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Mechanogenetic Toolkit for Interrogating Cell Signaling in Space and Time

Tools capable of imaging and perturbing mechanical signaling pathways with fine spatiotemporal resolution have been elusive, despite their importance in diverse cellular processes. The challenge in creating a mechanogenetic toolkit (i.e., selective and quantitative activation of genetically encoded mechanoreceptors) stems from the fact that many mechanically activated processes are localized in space and time yet additionally require mechanical loading to become activated. To address this challenge, we synthesized magnetoplasmonic nanoparticles that can image, localize, and mechanically load targeted proteins with high spatiotemporal resolution. We demonstrate their utility by investigating the cell-surface activation of two mechanoreceptors: Notch and E-cadherin. By measuring cellular responses to a spectrum of spatial, chemical, temporal, and mechanical inputs at the single-molecule and single-cell levels, we reveal how spatial segregation and mechanical force cooperate to direct receptor activation dynamics. This generalizable technique can be utilized to control and understand diverse mechanosensitive processes in cell signaling.

60 APPLIED LIFE SCIENCES↗

Characterization of mechanical behavior of an epithelial monolayer in response to epidermal growth factor stimulation

Cell signaling often causes changes in cellular mechanical properties. Knowledge of such changes can ultimately lead to insight into the complex network of cell signaling. In the current study, we employed a combination of atomic force microscopy (AFM) and quartz crystal microbalance with dissipation monitoring (QCM-D) to characterize the mechanical behavior of A431 cells in response to epidermal growth factor receptor (EGFR) signaling. From AFM, which probes the upper portion of an individual cell in a monolayer of cells, we observed increases in energy dissipation, Young's modulus, and hysteresivity. Increases in hysteresivity imply a shift toward a more fluid-like mechanical ordering state in the bodies of the cells. From QCM-D, which probes the basal area of the monolayer of cells collectively, we observed decreases in energy dissipation factor. This result suggests a shift toward a more solid-like state in the basal areas of the cells. The comparative analysis of these results indicates a regionally specific mechanical behavior of the cell in response to EGFR signaling and suggests a correlation between the time-dependent mechanical responses and the dynamic process of EGFR signaling. This study also demonstrates that a combination of AFM and QCM-D is able to provide a more complete and refined mechanical profile of the cells during cell signaling. -- Highlights: Black-Right-Pointing-Pointer The EGF-induced cellular mechanical response is regionally specific. Black-Right-Pointing-Pointer The EGF-induced cellular mechanical response is time and dose dependent. Black-Right-Pointing-Pointer A combination of AFM and QCM-D provides a more complete mechanical profile of cells.

60 APPLIED LIFE SCIENCES↗

Performance Comparison of Machine Learning Models for Ultrasonic Nondestructive Evaluation of Alkali-Silica Reaction in Concrete

Alkali-silica reaction (ASR) causes concrete degradation, leading to cracking, rebar corrosion, and reduced structural integrity, which raises safety concerns. Ultrasonic nondestructive evaluation (NDE) effectively assesses concrete properties and monitors ASR progression. However, its deployment and analysis require specialized expertise and subjective interpretation. As computational power increases, artificial intelligence (AI) and machine learning (ML) algorithms are increasingly being used to automate NDE data analysis across various industries for AI-assisted automation. Regulatory agencies are adapting to this technological shift, prompting a need to evaluate current ML technologies’ capabilities and limitations in assessing concrete material properties and damage. This report presents a comparative analysis of four ML regression models for predicting concrete material damage induced by ASR expansion using long-term ultrasonic data monitoring. The models investigated include linear regression (LR), support vector regression (SVR), shallow neural networks (NN), and deep neural networks (DNN). LR, SVR, and shallow NN models use features extracted from ultrasonic signals, whereas the DNN model processes time-domain ultrasonic signals and frequency spectra directly. The study systematically compared the models’ performance from various perspectives, including model input, prediction performance, and generalization ability. The findings indicate significant variability in model performance, with some ML algorithms achieving very high or very low prediction accuracy depending on the preprocessing and feature engineering (extraction and selection) applied. Key insights include the observation that shallow ML models (LR, SVR, and shallow NNs) require meticulous preprocessing and feature extraction to achieve high accuracy. In contrast, the DNN model, although it bypasses the need for feature engineering, necessitates extensive preprocessing to mitigate noise and computational demands. The SVR model emerged as the top performer among the shallow models, and the DNN model exhibited superior performance on specific datasets but struggled with generalization across specimens from different batches. Additionally, the SVR model is sensitive to temperature variations, whereas the DNN model is robust in this regard. Using recurrent neural networks is recommended for future ASR expansion prediction studies. Recurrent neural networks’ inherent ability to capture temporal dependencies and long-term patterns makes them well suited for analyzing sequential ultrasonic monitoring data. Overall, the results and conclusions of this study could provide insights into the capabilities and effectiveness of ML when applied to ultrasonic NDE data and help identify best practices for using ML for ultrasonic NDE of concrete material properties.

36 MATERIALS SCIENCE↗

Method and system for determining a geographical location of an unmanned aerial vehicle flown in proximity to a power grid

A method for determining geolocation of a UAV near a power grid includes detecting, via a transceiver, a carrier signal transmitted from a first grid node to identify the node's fixed geolocation. A response signal may be transmitted from a second grid node in response to the carrier signal to identify a fixed geolocation of the second grid node, or the UAV may process the carrier signal. A processor determines time-of-flight of the carrier signal, e.g., using the response signal, and derives the UAV's geolocation using the time-of-flight. Determining time-of-flight may include referencing a lookup table indexed by time-of-arrival at the transceiver of the modulated carrier and response signals. A timestamp may indicate time-of-transmission of the carrier and response signals, respectively. Deriving geolocation may include subtracting time-of-transmission of the response signal from that of the carrier signal. A system includes the processor and transceiver.

Moore, Andrew J.↗

ATom (Acoustic Tomography Processing Suite) [SWR-24-120]

Acoustic tomography seeks the best-fit fluctuating velocity and temperature fields that explain a collection of signal travel times in a region of interest. This codebase defines an end-to-end framework for executing turbulent field retrievals from acoustic signals, acoustic signal design and processing tools for the physical array, and analysis tool that leverage virtual acoustic tomography arrays based on large-eddy simulations of the atmospheric boundary layer.

Hamilton, Nicholas↗