Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Time Series Evaluation of Radiation Portal Monitor Data for Point Source Discrimination.

A novel algorithm approach to evaluating data from PVT-based Radiation Portal Monitor (RPM) systems is established. Time series of data from RPMs are evaluated for the presence of sources of interest by comparing the background to the vehicle spectrum at each successive time step, isolating the contribution of anomalous radiation. At each time in the data sequence, a “spectral distance” index is calculated using this method. This method may dramatically reduce systematic fluctuations due to background attenuation by a vehicle (the so-called “shadow shielding” effect), and allow for time-series matched filtering for discrimination of compact anomalous sources. This is attempted by using a wavelet filter function of similar size to the expected source profile on the output of the spectral distance method. Performance of this method is shown by analysis (injection studies) of a number of real drive-through data sets taken at a U.S. port of entry. Spectra from isotopes of interest are injected into the data set, and the resultant “benign” and “injected” data sets are analyzed with gross-counting, spectral distance, and spatial algorithms. The combination of spectral and spatial analysis methods showed a significant increase to detection performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intercomparison of Field Methods for Acquiring Ground Reflectance at Railroad Valley Playa for Spectral Calibration of Satellite Data

Ground reflectance was acquired at the Railroad Valley Playa calibration site in Nevada USA using different methods of collection. The data was collected near the time and date of Landsat 8 OLI and Sentinel-2 satellite overpasses so an inter-comparison could be made with the reflectance products to determine which method was more suitable for vicarious calibration. The field spectrometers and reference panels were characterized before the field campaign. A continuous acquisition method was compared to stop and measure collections. Both acquisition methods were collected along an 80 m east-west transect as well as for a series of north-south transects over an 80 x 320 m area, with the stop and measure method being performed at random sampling locations. The measurements were performed using two field spectrometers by three teams of two people to compare the repeatability. The aim of the field campaign was to determine the variability due to the operator and the method of collection.

Lau, Ian C.↗

Intercomparison of Field Methods for Acquiring Ground Reflectance at Railroad Valley Playa for Spectral Calibration of Satellite Data

Ground reflectance was acquired at the Railroad Valley Playa calibration site in Nevada USA using different methods of collection. The data was collected near the time and date of Landsat 8 OLI and Sentinel-2 satellite overpasses so an inter-comparison could be made with the reflectance products to determine which method was more suitable for vicarious calibration. The field spectrometers and reference panels were characterized before the field campaign. A continuous acquisition method was compared to stop and measure collections. Both acquisition methods were collected along an 80 m east-west transect as well as for a series of north-south transects over an 80 x 320 m area, with the stop and measure method being performed at random sampling locations. The measurements were performed using two field spectrometers by three teams of two people to compare the repeatability. The aim of the field campaign was to determine the variability due to the operator and the method of collection.

Lau, Ian C.↗

Cloud altitude determination from infrared spectral radiances

The CO2 slicing method is generally recognized as the most accurate means of inferring cloud altitude from passive infrared radiance observations. The method is applicable to semi-transparent and broken clouds. During the cirrus FIRE and COHMEX field experiments, CO2 channel radiance data suitable for cloud altitude specification were achieved from moderate spectral resolution satellite sounders (NOAA-TOVS and GOES-VAS) and from a High spectral resolution Interferometer Spectrometer (HIS) flown on the NASA U2/ER2 aircraft. Also aboard the ER2 was a down-looking active lidar unit capable of providing cloud top pressure verifications with high accuracy. A third instrument, the Multispectral Atmospheric Mapping Sensor (MAMS) provided 50 meter resolution infrared window data which is used wtih radiosonde data to verify the heights of middle and low level clouds. Comparisons of lidar and MAMS/radiosonde ground truth cloud heights are made with those determined from: high resolution (0.5/cm) HIS spectra, HIS spectra degraded to the moderate resolution (15/cm) of the VAS/TOVS instruments, and spectrally averaged HIS radiances for individual pairs of VAS spectral channels. The results show that the best results are achieved from high resolution spectra; the RMS difference with the ground truth is 23 mb. The RMS differences between the infrared radiance determination and ground truth increase by 35 percent when the spectral resolution is degraded to the moderate spectral resolution of the VAS/TOVS instruments and by 52 to 183 percent, depending upon channel combinations, when only two spectral channels at VAS/TOVS spectral resolution are used.

Smith, William L.↗

Permafrost Active Layer Seismic Interferometry Experiment (PALSIE).

We present findings from a novel field experiment conducted at Poker Flat Research Range in Fairbanks, Alaska that was designed to monitor changes in active layer thickness in real time. Results are derived primarily from seismic data streaming from seven Nanometric Trillium Posthole seismometers directly buried in the upper section of the permafrost. The data were evaluated using two analysis methods: Horizontal to Vertical Spectral Ratio (HVSR) and ambient noise seismic interferometry. Results from the HVSR conclusively illustrated the method's effectiveness at determining the active layer's thickness with a single station. Investigations with the multi-station method (ambient noise seismic interferometry) are continuing at the University of Florida and have not yet conclusively determined active layer thickness changes. Further work continues with the Bureau of Land Management (BLM) to determine if the ground based measurements can constrain satellite imagery, which provide measurements on a much larger spatial scale.

54 ENVIRONMENTAL SCIENCES↗

Stochastic finite difference lattice Boltzmann method for steady incompressible viscous flows

With the advent of state-of-the-art computers and their rapid availability, the time is ripe for the development of efficient uncertainty quantification (UQ) methods to reduce the complexity of numerical models used to simulate complicated systems with incomplete knowledge and data. The spectral stochastic finite element method (SSFEM) which is one of the widely used UQ methods, regards uncertainty as generating a new dimension and the solution as dependent on this dimension. A convergent expansion along the new dimension is then sought in terms of the polynomial chaos system, and the coefficients in this representation are determined through a Galerkin approach. This approach provides an accurate representation even when only a small number of terms are used in the spectral expansion; consequently, saving in computational resource can be realized compared to the Monte Carlo (MC) scheme. Recent development of a finite difference lattice Boltzmann method (FDLBM) that provides a convenient algorithm for setting the boundary condition allows the flow of Newtonian and non-Newtonian fluids, with and without external body forces to be simulated with ease. Also, the inherent compressibility effect in the conventional lattice Boltzmann method, which might produce significant errors in some incompressible flow simulations, is eliminated. As such, the FDLBM together with an efficient UQ method can be used to treat incompressible flows with built in uncertainty, such as blood flow in stenosed arteries. The objective of this paper is to develop a stochastic numerical solver for steady incompressible viscous flows by combining the FDLBM with a SSFEM. Validation against MC solutions of channel/Couette, driven cavity, and sudden expansion flows are carried out.

97 MATHEMATICS AND COMPUTING↗

Spectral induced polarization monitoring of induced calcite precipitation in subsurface sediments

Co-precipitation of contaminants within the crystalline structure of calcite is a promising natural attenuation or remedial technology being considered at contaminated sites. We explore the sensitivity of the spectral induced polarization (SIP) method to induced calcite precipitation in natural sediments as a path forward to non-invasively monitor these sites. We performed time-lapse column experiments using phased (I-IV) injections over 40 days on natural sediments from the Hanford Site (Washington State, USA). In the phased injections, abiotic calcite precipitation was induced and confirmed to have occurred. Previous work in glass beads and homogeneous sand was limited to high frequency detection of calcite, however in this work we observed the development of two polarization mechanisms, one at high frequency (>100 Hz) and one at low frequency (< 100 Hz). Based on the characteristic frequencies from the SIP high and low frequency regimes, characteristic length scales (L) were computed where the adsorption mode of Na+ versus Ca2+ was compared by using diffusion coefficients corresponding to Na+ versus an arithmetically averaged value for Na+ and Ca2+. Using the diffusion coefficient of Na+, the high frequency L was found to correlate well with the size of the calcite crystals. The low frequency L correlated well with the individual natural sediment grain sizes within the columns. During late experimental times (day 36 and 40), the characteristic low frequency in two of the experimental columns shifted to lower frequencies (<0.001 Hz) which may signify SIP sensitivity of the formed calcite with the sediment grains. In field applications, the development of a low frequency polarization length scale to monitor calcite precipitation is promising for field monitoring applications, however further laboratory work needs to be performed to examine the SIP sensitivity of calcite formation in the presence of to natural sediments

calcium carbonate, calcite, precipitation, spectra↗

AGE DETERMINATION FOR 346 NEARBY STARS IN THE HERSCHEL DEBRIS SURVEY

DEBRIS is a flux-limited survey of nearby stars (spectral types A-M) for evidence of debris disks with the Herschel Space Observatory. One goal of the survey is to determine disk incidence as a function of various stellar parameters. Understanding debris disk evolution depends on knowledge of the precise age of stars around which these debris disks are found. However, finding ages for field stars is notoriously difficult. Furthermore, in an unbiased sample like DEBRIS, one is working with stars across many spectral types. This requires a multi-method approach to age determination. In this paper, we outline several methods of age determination broken down by spectral type, including some strengths and limitations of each method. In total, we were able to calculate ages for 263 of 274 F-, G-, and K-type stars, and all 83 A-type stars in the DEBRIS sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AGNfitter: a Bayesian MCMC approach to fitting spectral energy distributions of AGNs

We present AGNfitter, a publicly available open-source algorithm implementing a fully Bayesian Markov Chain Monte Carlo method to fit the spectral energy distributions (SEDs) of active galactic nuclei (AGNs) from the sub-millimeter to the UV, allowing one to robustly disentangle the physical processes responsible for their emission. AGNfitter makes use of a large library of theoretical, empirical, and semi-empirical models to characterize both the nuclear and host galaxy emission simultaneously. The model consists of four physical emission components: an accretion disk, a torus of AGN heated dust, stellar populations, and cold dust in star-forming regions. AGNfitter determines the posterior distributions of numerous parameters that govern the physics of AGNs with a fully Bayesian treatment of errors and parameter degeneracies, allowing one to infer integrated luminosities, dust attenuation parameters, stellar masses, and star-formation rates. We tested AGNfitter’s performance on real data by fitting the SEDs of a sample of 714 X-ray selected AGNs from the XMM-COSMOS survey, spectroscopically classified as Type1 (unobscured) and Type2 (obscured) AGNs by their optical–UV emission lines. We find that two independent model parameters, namely the reddening of the accretion disk and the column density of the dusty torus, are good proxies for AGN obscuration, allowing us to develop a strategy for classifying AGNs as Type1 or Type2, based solely on an SED-fitting analysis. Our classification scheme is in excellent agreement with the spectroscopic classification, giving a completeness fraction of ∼86% and ∼70%, and an efficiency of ∼80% and ∼77%, for Type1 and Type2 AGNs, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Faster spectral density calculation using energy moments

Abstract Accurate predictions of inclusive scattering cross sections in the linear response regime require efficient and controllable methods to calculate the spectral density in a strongly-correlated many-body system. In this work we reformulate the recently proposed Gaussian Integral Transform technique in terms of Fourier moments of the system Hamiltonian which can be computed efficiently on a quantum computer. One of the main advantages of this framework is that it allows for an important reduction of the computational cost by exploiting previous knowledge about the energy moments of the spectral density. For a simple model of medium mass nucleus like $$^{40}$$ 40 Ca and target energy resolution of 1 MeV we find an expected speed-up of $$\approx 125$$ ≈ 125 times for the calculation of the giant dipole response and of $$\approx 50$$ ≈ 50 times for the simulation of quasi-elastic electron scattering at typical momentum transfers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using the procedure of spectral projection for reactivity determination in physically large nuclear reactors

The reactivity determination methods which are based on the neutron field reconstruction procedure and the spectral-projection method are analyzed. The approximate methods of reactivity determination which can be used in practice are offered. The efficiency of the proposed methods in comparison to that of the methods applied in operation of nuclear power plants is demonstrated using computational models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis and Validation of Spectral Irradiance Simulations for 75 kW Bifacial Solar Test Field

This work investigates how the spectrum of irradiance incident on the rear of bifacial modules impacts their performance. Light incident on the rear of bifacial modules can be reflected from the ground, mounting structures, and other nearby objects, causing both the intensity and spectrum to be modified. As a result, PV cells and sensors with different spectral responses report different values for the rear irradiance, leading to increased uncertainty when modeling performance. Here, we calculate the spectral irradiance incident on the rear of modules through raytrace simulations and validate with measured field data collected from a 75kW single-axis-tracked bifacial test site. Spectral responses for different sensors and PV cells are applied and compared with field measurements for four days. Based on these results, a method for improving non-spectral simulations is proposed. In addition, a linear regression is applied to the modeled spectral results as a method to gain insight into the contributions of ground reflected light to total rear irradiance.

bifacial photovoltaics↗

A survey of unsupervised learning methods for high-dimensional uncertainty quantification in black-box-type problems

Constructing surrogate models for uncertainty quantification (UQ) on complex partial differential equations (PDEs) having inherently high-dimensional O(10 n ), n ≥ 2, stochastic inputs (e.g., forcing terms, boundary conditions, initial conditions) poses tremendous challenges. The “curse of dimensionality” can be addressed with suitable unsupervised learning techniques used as a pre-processing tool to encode inputs onto lower-dimensional subspaces while retaining its structural information and meaningful properties. In this work, we review and investigate thirteen dimension reduction methods including linear and nonlinear, spectral, blind source separation, convex and non-convex methods and utilize the resulting embeddings to construct a mapping to quantities of interest via polynomial chaos expansions (PCE). Here, we refer to the general proposed approach as manifold PCE (m-PCE), where manifold corresponds to the latent space resulting from any of the studied dimension reduction methods. To investigate the capabilities and limitations of these methods we conduct numerical tests for three physics-based systems (treated as black-boxes) having high-dimensional stochastic inputs of varying complexity modeled as both Gaussian and non-Gaussian random fields to investigate the effect of the intrinsic dimensionality of input data. We demonstrate both the advantages and limitations of the unsupervised learning methods and we conclude that a suitable m-PCE model provides a cost-effective approach compared to alternative algorithms proposed in the literature, including recently proposed expensive deep neural network-based surrogates and can be readily applied for high-dimensional UQ in stochastic PDEs.

42 ENGINEERING↗

Comparing Top-Down Proteoform Identification: Deconvolution, PrSM Overlap, and PTM Detection

Generating top-down tandem mass spectra (MS/MS) for complex mixtures of proteoforms has become possible through improvements in fractionation, on-line separation, dissociation, and mass analysis. The algorithms to match tandem mass spectra to sequences have undergone a parallel evolution, with both spectral alignment and peak matching being paired with diverse methods for scoring proteoform-spectral matches (PrSMs). This study assesses state-of-the-art algorithms for top-down identification through three distinct challenges. The first is identifying a large yield of PrSMs while controlling false discovery rate (FDR) in identifying thousands of proteoforms from complex cell lysates via four software workflows: ProSight Proteome Discoverer, TopPIC, Informed Proteomics, and pTop. The second is the deconvolution of data from both Thermo Orbitrap-class and Bruker maXis Q-TOF instruments to produce consistent precursor charge and mass determinations while generating fragment mass lists to optimize identification. The third attempts to detect diverse post-translational modifications (PTMs) in proteoforms from cow milk and human ovarian tissue. The data demonstrate that existing software suites produce admirable sensitivity, in some cases identifying a third of collected tandem mass spectra with FDR controlled below 2%; the overlap in these PrSMs, however, illustrates real value in searching data with multiple search engines. Differences among identification workflows seem to result from each search algorithm incorporating its own deconvolution algorithm. By transmitting deconvolution data from multiple deconvolution routes (Thermo Xtract, Bruker Auto MSn, Mascot Distiller, TopFD, and FLASHDeconv) to the downstream TopPIC search algorithm, we were able to detect common causes of deconvolution disagreement. The detection of PTMs was very inconsistent among search algorithms, with some workflows suggesting as little as 1% of PrSMs from cow’s milk were singly-phosphorylated while other workflows found that 18% of PrSMs were singly-phosphorylated. Taken together, these results make a strong argument for top-down researchers to adopt a standard practice of analyzing each MS/MS experiment with at least two different search engines.

59 BASIC BIOLOGICAL SCIENCES↗

Photoelastic measurements of residual stresses for NDE

Photoelastic measurements of residual strains are used extensively in the QC and inspection of transparent materials. A new method of measurements, based on Spectral Contents Analysis, is described in this paper. The method uses a personal computer for photoelastic data acquisition, eliminating personal skill and subjectivity. the new tool should make the measurements of residual strains for QC simpler and more reliable.

Redner, Alex S.↗