Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Next Generation Big Data Storage for Long Space Missions

This paper presents the results of the HELIOS (Hardened Extremely Long Life In-formation Optical Storage) mission on the International Space Station (ISS) which tested a unique solution for the long-term storage and retrieval of data in space. For this mission Creative Technology (CTech) developed test media—termed WORF (Write Once, Read Forever)—to validate whether this patented technology will survive all critical parameters for harsh space-based environments including microgravity and ionizing radiation. The HELIOS experiment confirmed that the WORF media is impervious to ionizing radiation, microgravity, solar (plasma) eruptions, and the stress from 8 Gs of the launch including extreme temperature expo-sure. The principal results indicate that there has been no discernible degradation of the media after 8 months on the ISS as compared to a control set of media stored on the ground. This data validated the media’s survivability for harsh space environments for long-term and deep space missions. In addition to the space environment, we are confident that WORF technology can be used for data storage where space-related and other long-term or archival integrity is critical such as: geospatial collections from satellites; space weather archives; past, ongoing, and future space mission media and documentation files; the deep space Gate-way program; as well as Big Data applications such as the Vera C. Rubin astronomical observatory (formerly the LSST). WORF technology for the HELIOS experiment uses a proven archival media, redesigned, re-purposed and patented by CTech to store digital data for long periods, measured in decades and possibly centuries. The media stores standing waves embedded in a substrate that capture the precise col-ors or wavelengths projected onto the media. The colors represent numerical data, with each data location storing multiple superimposed wavelengths, which facilitate the storage of multiple data bytes (rather than just zeros and ones); advanced mathematical permutations allow for extremely large data density equal to or greater than contemporary data storage de-vices. These colors cannot fade or degrade over time since the standing waves are physically stabilized (fully oxidized) metallic silver; no dyes are embedded for this storage system, and silver ions resist micro-bacterial and fungal contamination

Rodney Grubbs↗

A Case for Optimistic Coordination in HPC Storage Systems

High-performance computing (HPC) storage systems rely on access coordination to ensure that concurrent updates do not produce incoherent results. HPC storage systems typically employ pessimistic distributed locking to provide this functionality in cases where applications cannot perform their own coordination. This approach, however, introduces significant performance overhead and complicates fault handling. In this work we evaluate the viability of optimistic conditional storage operations as an alternative to distributed locking in HPC storage systems. We investigate design strategies and compare the two approaches in a prototype object storage system using a parallel read/modify/write benchmark. Our prototype illustrates that conditional operations can be easily integrated into distributed object storage systems and can outperform standard coordination primitives for simple update workloads. Our experiments show that conditional updates can achieve over two orders of magnitude higher performance than pessimistic locking for some parallel read/modify/write workloads.

Carns, Philip↗

Subtask – CO 2 storage and enhanced bakken recovery research program

Small improvements in productivity could increase technically recoverable oil in the Bakken Petroleum System by billions of barrels. The use of CO 2 for enhanced oil recovery (EOR) in tight oil reservoirs is a relatively new concept. The large-scale injection of CO 2 into the Bakken would also result in the geological storage of significant amounts of CO 2 . The Energy & Environmental Research Center (EERC) has conducted laboratory and modeling activities to examine the potential for CO 2 storage and EOR in the Bakken. Specific activities included the characterization and subsequent modeling of North Dakota study areas as well as dynamic predictive simulations of possible CO 2 injection schemes to predict the potential CO 2 storage and EOR in those areas. Laboratory studies to evaluate the ability of CO 2 to remove hydrocarbons from Bakken rocks and determine minimum miscibility pressures for Bakken oil samples were conducted. Data from a CO 2 injection test conducted in the Elm Coulee area of Montana in 2009 were evaluated with an eye toward the possible application of knowledge gained to future injection tests in other areas. A first-order estimation of potential CO 2 storage capacity in the Bakken Formation in North Dakota was also conducted. Key findings of the program are as follows. The results of the research activities suggest that CO 2 may be effective in enhancing the productivity of oil from the Bakken and that the Bakken may hold the ability to geologically store between 120 Mt and 3.2 Gt of CO 2 . However, there are no clear-cut answers regarding the most effective approach for using CO 2 to improve oil productivity or the storage capacity of the Bakken. The results underscore the notion that an unconventional resource will likely require unconventional methods of both assessment and implementation when it comes to the injection of CO 2 . In particular, a better understanding of the fundamental mechanisms controlling the interactions between CO 2 , oil, and other reservoir fluids in these unique formations is necessary to develop accurate assessments of potential CO 2 storage and EOR in the Bakken. In addition, existing modeling and simulation software packages do not adequately address or incorporate the unique properties of these tight, unconventional reservoirs in terms of their impact on CO 2 behavior. These knowledge gaps can be filled by conducting scaled-up laboratory activities integrated with improved modeling and simulation techniques, the results of which will provide a robust foundation for pilot-scale field injection tests. Finally, field-based data on injection, fluid production, and long-term monitoring from pilot-scale CO 2 injection tests in the Bakken are necessary to verify and validate the findings of the laboratory- and modeling-based research efforts. This subtask was funded through the EERC–U.S. Department of Energy (DOE) Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the North Dakota Industrial Commission, Marathon Oil Corporation, Continental Resources Inc., and TAQA North, Ltd.

54 ENVIRONMENTAL SCIENCES↗

Subtask1.10 – CO 2 storage and enhanced bakken recovery research program

Small improvements in productivity could increase technically recoverable oil in the Bakken Petroleum System by billions of barrels. The use of CO 2 for enhanced oil recovery (EOR) in tight oil reservoirs is a relatively new concept. The large-scale injection of CO 2 into the Bakken would also result in the geological storage of significant amounts of CO 2 . The Energy & Environmental Research Center (EERC) has conducted laboratory and modeling activities to examine the potential for CO 2 storage and EOR in the Bakken. Specific activities included the characterization and subsequent modeling of North Dakota study areas as well as dynamic predictive simulations of possible CO 2 injection schemes to predict the potential CO 2 storage and EOR in those areas. Laboratory studies to evaluate the ability of CO 2 to remove hydrocarbons from Bakken rocks and determine minimum miscibility pressures for Bakken oil samples were conducted. Data from a CO 2 injection test conducted in the Elm Coulee area of Montana in 2009 were evaluated with an eye toward the possible application of knowledge gained to future injection tests in other areas. A first-order estimation of potential CO 2 storage capacity in the Bakken Formation in North Dakota was also conducted. Key findings of the program are as follows. The results of the research activities suggest that CO 2 may be effective in enhancing the productivity of oil from the Bakken and that the Bakken may hold the ability to geologically store between 120 Mt and 3.2 Gt of CO 2 . However, there are no clear-cut answers regarding the most effective approach for using CO 2 to improve oil productivity or the storage capacity of the Bakken. The results underscore the notion that an unconventional resource will likely require unconventional methods of both assessment and implementation when it comes to the injection of CO 2 . In particular, a better understanding of the fundamental mechanisms controlling the interactions between CO 2 , oil, and other reservoir fluids in these unique formations is necessary to develop accurate assessments of potential CO 2 storage and EOR in the Bakken. In addition, existing modeling and simulation software packages do not adequately address or incorporate the unique properties of these tight, unconventional reservoirs in terms of their impact on CO 2 behavior. These knowledge gaps can be filled by conducting scaled-up laboratory activities integrated with improved modeling and simulation techniques, the results of which will provide a robust foundation for pilot-scale field injection tests. Finally, field-based data on injection, fluid production, and long-term monitoring from pilot-scale CO 2 injection tests in the Bakken are necessary to verify and validate the findings of the laboratory- and modeling-based research efforts. This subtask was funded through the EERC–U.S. Department of Energy (DOE) Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the North Dakota Industrial Commission, Marathon Oil Corporation, Continental Resources Inc., and TAQA North, Ltd.

54 ENVIRONMENTAL SCIENCES↗

An analysis of image storage systems for scalable training of deep neural networks

This study presents a principled empirical evaluation of image storage systems for training deep neural networks. We employ the Caffe deep learning framework to train neural network models for three different data sets, MNIST, CIFAR-10, and ImageNet. While training the models, we evaluate five different options to retrieve training image data: (1) PNG-formatted image files on local file system; (2) pushing pixel arrays from image files into a single HDF5 file on local file system; (3) in-memory arrays to hold the pixel arrays in Python and C++; (4) loading the training data into LevelDB, a log-structured merge tree based key-value storage; and (5) loading the training data into LMDB, a B+tree based key-value storage. The experimental results quantitatively highlight the disadvantage of using normal image files on local file systems to train deep neural networks and demonstrate reliable performance with key-value storage based storage systems. When training a model on the ImageNet dataset, the image file option was more than 17 times slower than the key-value storage option. Along with measurements on training time, this study provides in-depth analysis on the cause of performance advantages/disadvantages of each back-end to train deep neural networks. We envision the provided measurements and analysis will shed light on the optimal way to architect systems for training neural networks in a scalable manner.

Lim, Seung-Hwan↗

Single bi-temperature thermal storage tank for application in solar thermal plant

Thermocline storage tanks for solar power systems are disclosed. A thermocline region is provided between hot and cold storage regions of a fluid within the storage tank cavity. One example storage tank includes spaced apart baffles fixed relative to the tank and arranged within the thermocline region to substantially physically separate the cavity into hot and cold storage regions. In another example, a flexible baffle separated the hot and cold storage regions and deflects as the thermocline region shifts to accommodate changing hot and cold volumes. In yet another example, a controller is configured to move a baffle within the thermocline region in response to flow rates from hot and cold pumps, which are used to pump the fluid.

14 SOLAR ENERGY↗

Key-value store with internal key-value storage interface

A key-value store is provided having one or more key-value storage interfaces. A key-value store on at least one compute node comprises a memory for storing a plurality of key-value pairs; and an abstract storage interface comprising a software interface module that communicates with at least one persistent storage device providing a key-value interface for persistent storage of one or more of the plurality of key-value pairs, wherein the software interface module provides the one or more key-value pairs to the at least one persistent storage device in a key-value format. The abstract storage interface optionally processes one or more batch operations on the plurality of key-value pairs. A distributed embodiment for a partitioned key-value store is also provided.

97 MATHEMATICS AND COMPUTING↗

A Stratigraphic Approach to Characterize the Deposition and Storage of Organic Matter in Reservoir Sediments.

The relationship between carbon burial and sedimentation in reservoirs is unknown, exposing gaps in our fundamental understanding of the transport, processing, and deposition of sediment and organic matter in fluvial and lacustrine systems and contributing to uncertainty in our understanding of the net impact of dams to the global carbon budget. The 2011-2014 removal of two large dams on the Elwha River, Washington State, the largest dam removal yet completed globally, created extensive cutbank exposures of reservoir sediments, allowing the first characterization of the facies architecture of sediments through direct observation in reservoirs worldwide and providing an unparalleled opportunity to 1) assess the relationship between environmental influences, such as and changes in sediment supply, and their expression in the stratigraphic record, 2) assess the relationship between sedimentation processes and detrital organic carbon deposition and storage, and the importance of coarse-grained organic matter and woody debris to the total carbon budget of a reservoir, and 3) apply the insight gained from these reservoirs to evaluate current global estimates of carbon storage in reservoirs and develop a conceptual model of carbon burial in reservoirs to guide further research, as defined by characteristic stratigraphic “types”. Former Lake Mills, the younger, upstream reservoir, was characterized by a tripartite, subaerial Gilbert-style delta which prograded >1 km into the main reservoir from 1927 to 2011. Sediments were composed of coarse-grained topset beds, steeply dipping foreset beds, and a fine-grained, gently dipping prodelta. While individual event horizons were discernible in fine-grained sediments of former Lake Mills, their number and spacing did not correspond to known drawdown or flood events. Former Lake Aldwell, impounded from 1913 to 2011, was initially defined by the rapid progradation of a Gilbert-style, subaerial delta prior to the upstream completion of Glines Canyon Dam. However, the 1927 closure of Glines Canyon Dam upstream caused the delta to evolve to a fine-grained, mouth-bar type delta indicative of low, finer-grained sediment. This evolution, combined with a previously-unrecognized landslide deposit into the upper delta plain, suggests that understanding the exogenic influences on reservoir sedimentation is critical to interpretation and prediction of the sedimentation within individual systems. Former Lake Mills accumulated ~330 Gg of, with depositional-zone average accumulation rates from 229 to 9262 gCm -2 yr -1 , while Former Lake Aldwell accumulated ~ 91 Gg (263 to 2414 gCm -2 yr -1 ). Carbon storage in both reservoirs was dominated by heterogeneous, coarse organic matter and woody debris in the coarse-grained delta slope and relatively coarse-grained prodelta regions of the reservoirs, with little storage in the gravel-dominated, subaerial delta plains. Carbon accumulation in fine-grained lacustrine and prodelta sediments was relatively homogeneous, but turbidity flows from the Gilbert-style delta slope in former Lake Mills delivered significantly more carbon to the prodelta than the mouth-bar style delta of former Lake Aldwell. C:N ratios support interpretation of most organic matter in both reservoirs as allochthonous. Sampling schemes based only on lacustrine and/or prodelta would underestimate of total carbon accumulation by up to 30% in former Lake Aldwell, but the overestimate by up to 47% in former Lake Mills. Global estimates of carbon sequestration rates in reservoir sediments vary by three orders of magnitude, while individual-reservoir estimates vary by four orders of magnitude and over only 37 reservoirs and a literature review of predictive variables suggests weak or contradictory relationships. A conceptual stratigraphic framework of four unique reservoir types suggests that organic matter deposition is intrinsically tied to sedimentation processes and that patterns of carbon storage vary systematically with the stratigraphy of reservoir sediments. Deltaically-dominated reservoirs (whether Gilbert style or shoalwater) appear to store most carbon in their deltaic and prodelta regions, while thalweg-style reservoirs exhibit a bimodal distribution, with allochthonous carbon preferentially routed along the former river thalweg and autochthonous deposited on the former floodplain. Lacustrine-style reservoirs are dominated by suspended sediment deposition and thus relatively homogeneous, but literature suggests these reservoirs are more variable than typically measured. Current methods of reservoir sampling fail to account for this systematic variation and tend to be biased toward fine sediment, suggesting that global reservoir carbon storage is underestimated.

Stratton, Laurel↗

Conceptual Design Study of a Thermal Energy Storage System Using Granular Solids for Coal-fired Boilers

<span style="font-size: 12pt;">Presentation for the 2020 International Pittsburgh Coal Conference held virtually from September 8-11, 2020.</span><span style="font-size: 12pt;">Abstract: As electricity from various renewable energy sources is increasingly supplied to the power grid, the grid’s stability will be challenged. Proposed grid-stability solutions will need to address variability of sources, such as solar and wind energy, in order to alleviate problems such as overgeneration and ramping. In regions where increases in solar energy are prominent, such as California, the net power demand curve often referred to as “the Duck Curve,” has caused problems for energy dispatchers, due to over-generation and fast ramping demands. In this project, we investigated a conceptual design for a Thermal Energy Storage System (TESS) integrated into a coal-fired power plant to support grid-scale storage. Implementing a TESS into power plants can allow for an increase in renewable sources, increase grid resilience, and allow conventional coal-fired plants to operate more efficiently. For this project, a TESS using granular solids as the energy-storage media is integrated into a conventional coal-fired power plant. The purpose of the TESS is to store energy from the flue gas during low demand periods and transfer the energy to steam during peak demand periods. The storage allows the stabilization of combustion and related boiler components at low loads and provides the opportunity to avoid some shutdowns. This study uses thermodynamic properties of several candidate thermal storage materials to estimate the size of storage system required for several operating scenarios. </span>

Huckaby, E. David↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

WBS 1.2.3.405 - Life Cycle Assessment of Storage Technologies

Recent commitments by the Biden administration have established targets to achieve a net-zero energy system by 2050. Meeting these targets will spur a rapid transition to clean energy technologies and a commensurate need to develop and deploy energy storage technologies at scale. Pumped Storage Hydro (PSH) is expected to be part of this solution because its ability to provide grid flexibility and stability and enable the dispatching of disparate variable renewable energy technologies. Despite PSH being a mature technology with a history of deployment dating back several decades, there is very little information on the greenhouse gas (GHG) implications of PSH as compared to other storage technologies. The objective of this project is to perform a full lifecycle assessment (LCA) of new PSH projects in the U.S. This LCA includes all project phases (resource extraction, construction, operation, maintenance, end-of-life). The functional unit for this study is 1 kWh electricity delivered by system to grid substation connection point and the estimated lifetime for our base case is 80 years. Data used in this study are based on over 30 potential PSH projects that are in preliminary planning phases and are represent a wide range of potential closed-loop PSH systems in terms of location, technology, and capacity. The project approach, data sources, and modeling assumptions have been informed by a technical review committee of stakeholders that include experts from academia, national and international government, industry, and utilities. The GHGs and energy return on investment (EROI) from PSH will be compared to other storage technologies (e.g., stationary battery storage). Results from this project will improve the PSH community's understanding of the environmental impacts and sustainability of new PSH projects and how PSH compares to other storage technologies. The approach used in this project relies on open-source programming. The analysis framework (source code and data) and will be made publicly available at the end of the project. In addition to reporting results for the base case, we will perform rigorous sensitivity analysis to identify the major drivers, understand impacts of different configurations, and future energy markets. Results from this project will be published in a suitable journal.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

ASSESSING MATERIAL DEGRADATION EFFECTS ON LONG TERM STORAGE STRUCTURAL ANALYSES

PNNL staff are currently working to conduct analyses, integrate experimental data, and develop the technical basis for extended long term storage and subsequent transportation of used nuclear fuel. Analyses will serve to augment the experimental work by addressing degradation phenomena not readily obtainable through experimentation, such as low temperature creep over very long periods of time. Analyses can also address issues such as concrete degradation that may not require a comprehensive R&D program to resolve, as well as evaluation of engineering design solutions that can be implemented to mitigate the amount and extent of experimental data needed. Most importantly, analyses are necessary to determine how much degradation any structure, system, or component can experience and still maintain its ability to meet its safety functions. This paper focuses on various structural modeling issues that are affected by material degradation in extended long term storage scenarios. Typical storage cask and transportation package designs have a safety basis that includes a number of structural static or dynamic finite element analysis (FEA) models. Some of the features of these standard models need to be reconsidered when the fuel is in an extended long term storage state. In this paper, a number of standard safety basis FEA models are discussed and evaluated for their applicability to long term storage scenarios. A vertical handling drop analysis is used to illustrate a case where additional modeling is needed to define the loads and loading history needed to properly evaluate material degradation in long term storage scenarios.

Klymyshyn, Nicholas A.↗

Multi factor Assessment for Decarbonization via Technically Viable Carbon Storage

Final poster presenting research under EDX4CCS portfolio, Task 21, on multi-factor assessment for technically viable carbon storage. To date, carbon storage viability assessments have focused on the technically recoverable storage resources to estimate the volume of carbon storage in reservoirs targeted for geologic carbon sequestration. The Carbon Storage Technical Viability Approach (CS TVA) was developed to account for all factors determining the viability of carbon storage at a given site, including socioeconomic and environmental aspects in addition to the classic subsurface geologic assessment. Abstract accepted to the American Geophysical Union Fall Meeting 2023.

Mark-Moser, Mackenzie K.↗

Thermo-Hydrological Modeling of Thermal Energy Storage in a Depleted Oil Reservoir

Thermal energy storage in oil and gas reservoirs leverages the existing surface and subsurface infrastructure, which can pave the way for economic production of geothermal energy. Existing studies on geothermal energy storage are focused mostly on the use of aquifers with more homogeneous rock and fluid properties. Coupling of heat and fluid flow in a multiphase-multicomponent system, such as an oil reservoir, is imperative especially if existing oil field assets need to be repurposed as required for a sustainable energy transition. The objective is to model the subsurface thermo-hydrological processes associated with reservoir performance and operational sustainability. The model evaluates formation pressure and temperature within the reservoir and at the injection/production wells during multiple charge and discharge cycles. Hot water (approximately 200 degrees C) heated by Concentrating Solar Power (CSP) at high pressure is injected into the existing oil reservoir for storage and produced as thermal energy for power generation, which will be accompanied by enhanced oil recovery. To demonstrate the coupled fluid and heat flow during the injection/production cycle in the subsurface reservoir, TOUGH3 (developed by Berkeley Lab) is used to simulate the thermo-hydrological (TH) processes in a multiphase, multicomponent system. Two well geometries are considered within the reservoir grid: 1) a single-well huff-n-puff system (same well is used for injection and production), and 2) an isolated injection-production well doublet. Seasonal charge and discharge cycling are implemented based on the scheduling specified in the model input file. The model reports pressure, temperature, enthalpy, liquid fluxes, heat fluxes, pore velocities, and changes in porosity & permeability due to temperature and pressure variations during the cyclic Reservoir Thermal Energy Storage (RTES) operations. The results from the simulations can be used to optimize the operational parameters (such as well spacing and injection/production rates) and round-trip efficiency for surface power-plants coupled with thermal energy storage over time. They can also serve as important inputs for levelized cost of storage estimations. The research will help to design and integrate surface renewable energy sources, such as concentrating solar power (CSP), with RTES to help balance out power supply and demand on the grid.

CSP↗

Modeling the Cost of Onshore CO2 Pipeline Transport and Onshore CO2 Saline Storage

This paper describes the FECM/NETL CO2 Transport Cost Model (CO2_T_COM), a technoeconomic model of CO2 transport by pipeline, and the FECM/NETL CO2 Saline Storage Cost Model (CO2_S_COM), a technoeconomic model of storage of CO2 in a deep, subsurface saline formation. The results of applying CO2_T_COM to calculate break-even CO2 prices to transport CO2 at different mass flow rates and different distances are presented. Similarly, CO2_S_COM is used to calculate the break-even CO2 price for storing CO2 in 314 potential storage formations across the US. These break-even prices are used to construct cost-supply curves for CO2 storage which are presented on a national and regional basis. CO2_T_COM and CO2_S_COM are the most comprehensive open source technoeconomic models available for analyzing CO2 pipeline transport and CO2 saline storage. To be presented at the SPE?AAPG/SEG Carbon Capture Utilization and Storage Conference in Houston, TX, March 11-13, 2024.

Morgan, David↗

Systems, methods, and devices for failure detection of one or more energy storage devices

An energy storage device management system can include a management portion for charging/discharging an energy storage device and an ultrasound interrogation portion for passing ultrasound energy through the energy storage device during charge/discharge cycles. A memory stores a stream of capture data instances derived from ultrasound energy exiting the energy storage device and baseline ultrasound data instances corresponding with the energy storage device during normal charging/discharging thereof. A processor can compare each capture data instance with the baseline ultrasound data and detect abnormal operating states of the energy storage device. A warning system can issue a notification when abnormal operating states are detected.

Kowalski, Jeffrey A.↗

Considerations for Thermal Annealing of Zr-Alloy Cladding During Dry Storage

In January 2025, the U.S. Department of Energy (DOE) sponsored a technical workshop with fuel vendors that provided a forum for increased collaboration on backend fuel cycle research. The workshop reviewed observations of thermal annealing of irradiated zirconium alloys in simulated dry storage conditions and discussed implications to the industry’s interest in reducing wet storage to optimize operational flexibility and the expected trend of increasing discharge burnup (and decay heats), which could lead to an increase in dry storage temperatures. One approach to accommodate increased decay heats in dry storage is to increase the regulatory temperature limit during dry storage, which is now 400°C. However, this could lead to thermal annealing of the cladding, which will tend to increase creep rates, creep strains, and ductility while decreasing yield strength. These considerations are compounded by bonding between the pellet and cladding at high burnup, which results in the pellet carrying more load during fuel rod deformations, especially in bending, which is the dominant deformation phenomenon in canister drop analyses. Because the U.S. Nuclear Regulatory Commission (NRC) recommends yield strength as a primary failure criterion for accident analyses in storage and transportation, particularly for canister drop scenarios, the purpose of the workshop was to develop options for alternative failure criterion that could replace yield strength in canister drop analyses. Topics discussed were (1) the regulatory framework, (2) the effect of thermal annealing on microhardness and tensile properties of cladding materials, (3) the effect of thermal annealing on fuel rod failure during bending, bending fatigue, and pinch loading, and (4) an alternative failure criterion for canister drop analyses. This paper provides a summary of the key discussions and outcomes of the workshop

Cantonwine, Paul [ORNL] (ORCID:0009000522247033)↗

Performance of an Isobaric Hybrid Compressed Air Energy Storage System at Minimum Entropy Generation

Efficient, large-scale, and cost-effective energy storage systems provide a means of managing the inherent intermittency of renewable energy sources and drastically increasing their utilization. Compressed air energy storage (CAES) and its derivative architectures have received much attention as a viable solution; however, optimization objectives for these systems have not been thoroughly investigated in the literature. In this work, a hybrid thermal and compressed air energy storage (HT-CAES) system is investigated that mitigates the shortcomings of the otherwise attractive conventional CAES systems and its derivatives—shortcomings such as strict geological locations, low energy densities, and the production of greenhouse gas emissions. The HT-CAES system allows a portion of the available energy to operate a compressor and the remainder to be converted and stored in the form of heat through joule/resistive heating in a high-temperature, sensible, thermal energy storage medium. Internally reversible and irreversible HT-CAES system assumptions were investigated, in addition to regenerative and non-regenerative design configurations. Several system optimization criteria were examined—including maximum energy efficiency, maximum exergy efficiency, maximum work output, and minimum entropy generation—with a focus on whether the latter may lead to conclusive design guidelines in a real system. It is shown that an HT-CAES system designed based on a minimum entropy generation objective may operate at a lower energy and exergy efficiency as well as lower output power than otherwise achievable. Furthermore, optimization objective equivalence is shown to be limited to certain design conditions.

25 ENERGY STORAGE↗