ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

Combining low-energy electron microscopy and scanning probe microscopy techniques for surface science: Development of a novel sample-holder

We introduce an experimental facility dedicated to surface science that combines Low-Energy Electron Microscopy/Photo-Electron Emission Microscopy (LEEM/PEEM) and variable-temperature Scanning Probe Microscopy techniques. A technical challenge has been to design a sample-holder that allows to exploit the complementary specifications of both microscopes and to preserve their optimal functionality. Experimental demonstration is reported by characterizing under ultrahigh vacuum with both techniques: Au(111) surface reconstruction and a two-layer thick graphene on 6H-SiC(0001). A set of macros to analyze LEEM/PEEM data extends the capabilities of the setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heterogeneous reaction of ozone with aluminum oxide

Rates and collision efficiencies for ozone decomposition on aluminum oxide surfaces were determined. Samples were characterized by BET surface area, X-ray diffraction, particle size, and chemical analysis. Collision efficiencies were found to be between 2 times 10 to the -10 power and 2 times 10 to the -9 power. This is many orders of magnitude below the value of 0.000001 to 0.00001 needed for appreciable long-term ozone loss in the stratosphere. An activation energy of 7.2 kcal/mole was found for the heterogeneous reaction between -40 C and 40 C. Effects of pore diffusion, outgassing and treatment of the aluminum oxide with several chemical species were also investigated.

Keyser, L. F.↗

Ar-Ar Ages of Nakhlites Y000593, NWA998, and Nakhla and CRE Ages of NWA998

The seven known Martian nakhlites are Nakhla, Lafayette, Governador Valadares, and four recent finds from hot and cold deserts: MIL03346 from the Transantarctic Mountains, a paired group from the Yamato Mountains (Y000593, Y000749, and Y000802, and two from Morocco (NWA998 and NWA817. Radiometric ages (Sm-Nd, Rb-Sr, U-Pb, and Ar-Ar) for the first three nakhlites, along with Chassigny, fall in the range of 1.19-1.37 Gyr and may suggest a common formation age. These meteorites also show very similar cosmic-ray (space) exposure ages, suggesting a single ejection event from Mars. The ages for nakhlites are different from those of Martian shergottites, whose radiometric ages vary by nearly a factor of three (approx. 165-475 Myr) and whose space exposure ages vary over a factor of approx. 20. Shergottite ages suggest that multiple locations on the Martian surface have been sampled, whereas nakhlite data imply sampling of only one Mars surface location. Because older Martian surfaces are expected to be more abundant, it seems surprising that all nakhlites would represent only one Martian impact event. To address this issue, we are measuring the (39)Ar-(40)Ar ages of Y-000593, NWA-998, Nakhla, and MIL-03346, and the space (CRE) exposure age of NWA998. Additional information is included in the original extended abstract.

Garrison, D. H.↗

Microbial Air and Surface Monitoring Results from International Space Station Samples

Over the course of long-duration spaceflight, spacecraft develop a microbial ecology that directly interacts with the crew of the vehicle. While most microorganisms are harmless or beneficial to the inhabitants of the vehicle, the presence of medically significant organisms appearing in this semi-closed environment could adversely affect crew health and performance. The risk of exposure of the crew to medically significant organisms during a mission is estimated using information gathered during nominal and contingency environmental monitoring. Analysis of the air and surface microbiota in the habitable compartments of the International Space Station (ISS) over the last four years indicate a high presence of Staphylococcus species reflecting the human inhabitants of the vehicle. Generally, air and surface microbial concentrations are below system design specifications, suggesting a lower risk of contact infection or biodegradation. An evaluation of sample frequency indicates a decrease in the identification of new species, suggesting a lower potential for unknown microorganisms to be identified. However, the opportunistic pathogen, Staphylococcus aureus, has been identified in 3 of the last 5 air samples and 5 of the last 9 surface samples. In addition, 47% of the coagulase negative Staphylococcus species that were isolated from the crew, ISS, and its hardware were found to be methicillin resistance. In combination, these observations suggest the potential of methicillin resistant infectious agents over time.

Ott, C. Mark↗

Mixed Waste Landfill Annual Long-Term Monitoring & Maintenance Report April 2016-March 2017

Sampling activities for this reporting period included two semiannual monitoring events each for groundwater, soil-vapor, and radon. Annual soil-moisture monitoring was conducted in April 2016, annual tritium surface soil sampling was conducted in August 2016, and annual biota sampling (metals and radionuclides) was conducted in September 2016. All monitoring activities were conducted in accordance with LTMMP requirements and no monitoring results exceeded LTMMP trigger levels. All monitoring results were consistent with historic MWL monitoring data. Inspections of the MWL final cover system, storm-water diversion structures, compliance monitoring systems, and security fence were performed in accordance with LTMMP requirements. Required maintenance and repairs were minor and were generally performed during the inspections. The Evapotranspirative (ET) Cover continues to meet successful revegetation criteria and is in excellent condition with even coverage of mature, native perennial grasses. Maintenance was performed during the reporting period as a best management practice for ET Cover vegetation, and included a lower level of effort relative to previous years. The purpose of ongoing ET Cover maintenance efforts is to promote the growth and health of the desired native grass species by reducing competition with weedy species for limited moisture and nutrients. Based on previous inspections, additional best management practice activities were conducted during this reporting period to improve the site and reduce long-term ET Cover and site maintenance. These activities included improvements to site access and drainage (i.e., improvements to the access and perimeter road) and the installation of erosion and burrow control measures at the ten perimeter monitoring well locations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study of radiation damage and structure of Luna 16 sample particles using high-resolution electron microscopes

Using an electron scanning microscope and a high voltage microscope, a study was made of the radiation damage and structure of micron sized grains and grains separated from the 200-mesh fraction of the L-16-19 surface material sample. Then the structural features were compared with those found by studying with the same techniques grains separated from 20 different samples of lunar dust taken from the Apollo 11, Apollo 12, Apollo 14, and Apollo 15 collections. The L-16-19 sample is similar to the most intensely irradiated samples returned to earth by Apollo craft.

Borg, J.↗

Lunar sample analysis

The surface composition of lunar fines, the solar wind sputtering process, and the profile of reduced Fe in lunar samples are reported. Atomic absorption studies of trace metal, especially lead, distribution in lunar fines samples are described.

Housley, R. M.↗

Benchmarking an Embedded Adaptive Sampling Configuration Interaction Method for Surface Reactions: H 2 Desorption from and CH 4 Dissociation on Cu(111)

Embedded (emb-) correlated wavefunction (CW) theory enables accurate assessments of both ground- and excited-state reaction mechanisms involved in heterogeneous catalysis. Embedded multireference second-order perturbation theory (emb-MRPT2) based on reference wavefunctions generated via embedded complete active space self-consistent field (emb-CASSCF) theory is currently state-of-the-art. However, the factorial scaling of CASSCF limits the size of active space and the complexity of systems that can be studied. In this work, we assess the efficacy of an alternative CW method, adaptive sampling configuration interaction (ASCI)–which enables large active spaces to be used–for studying surface reactions. We couple ASCI with density functional embedding theory (DFET) and benchmark its performance for two reactions: H 2 desorption from and CH 4 dissociation on the Cu(111) surface. Unlike embedded complete active space second-order perturbation theory (emb-CASPT2) that accurately reproduces a measured H 2 desorption barrier, embedded ASCI, using a very large active space (though one that still comprises a small portion of the full set of orbitals) fails to do so. Adding an extra correlation term from embedded Møller–Plesset second-order perturbation theory (emb-MP2) improves the desorption barrier and endothermicity predictions. Thus, the inaccuracy of embedded ASCI comes from the missing dynamic correlation from the many other electrons and orbitals not included in the active space. For CH 4 dissociation, again embedded ASCI overestimates the dissociation barrier compared to emb-CASPT2 predictions. Adding dynamic correlation from emb-MP2 helps correct the barrier. However, this composite approach suffers from double counting of correlation within embedded ASCI followed by emb-MP2 calculations. We therefore conclude that the state-of-the-art emb-MRPT2 based on reference wavefunctions generated via emb-CASSCF remains the method of choice for studying surface reactions. emb-ASCI is useful when large active spaces beyond the limit of emb-CASSCF are essential, such as to study complex surface reactions with significant multiconfigurational character (static correlation) but weak dynamic correlation.

08 HYDROGEN↗

Thermal Infrared Spectral Band Detection Limits for Unidentified Surface Materials

Infrared emission spectra recorded by airborne or satellite spectrometers can be searched for spectral features to determine the composition of rocks on planetary surfaces. Surface materials are identified by detections of characteristic spectral bands. We show how to define whether to accept an observed spectral feature as a detection when the target material is unknown. We also use remotely sensed spectra measured by the Thermal Emission Spectrometer (TES) and the Spatially Enhanced Broadband Array Spectrograph System to illustrate the importance of instrument parameters and surface properties on band detection limits and how the variation in signal-to-noise ratio with wavelength affects the bands that are most detectable for a given instrument. The spectrometer's sampling interval, spectral resolution, signal-to-noise ratio as a function of wavelength, and the sample's surface properties influence whether the instrument can detect a spectral feature exhibited by a material. As an example, in the 6-13 micrometer wavelength region, massive carbonates exhibit two bands: a very strong, broad feature at approximately 6.5 micrometers and a less intense, sharper band at approximately 11.25 micrometers. Although the 6.5-micrometer band is stronger and broader in laboratory-measured spectra, the 11.25-micrometer band will cause a more detectable feature in TES spectra.

Kirkland, Laurel E.↗

Atmospheric Electron-Induced X-Ray Spectrometer (AEXS) Development

This paper describes the progress in the development of the so-called Atmospheric Electron X-ray Spectrometer (AEXS) instrument in our laboratory at JPL. The AEXS is a novel miniature instrument concept based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in situ, in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. By using a focused electron beam, the impinging electrons on samples in the external atmosphere excite XRF spectra from the irradiated spots with high-to-medium spatial resolution. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition. The use of high- intensity electron beam results in rapid spectrum acquisition (several minutes), and consequently low energy consumption (several tens of Joules) per acquired XRF spectrum in comparison to similar portable instruments.

X-ray fluorescence (XRF)↗

Field Geologic Observation and Sample Collection Strategies for Planetary Surface Exploration: Insights from the 2010 Desert RATS Geologist Crewmembers

Observation is the primary role of all field geologists, and geologic observations put into an evolving conceptual context will be the most important data stream that will be relayed to Earth during a planetary exploration mission. Sample collection is also an important planetary field activity, and its success is closely tied to the quality of contextual observations. To test protocols for doing effective planetary geologic field- work, the Desert RATS(Research and Technology Studies) project deployed two prototype rovers for two weeks of simulated exploratory traverses in the San Francisco volcanic field of northern Arizona. The authors of this paper represent the geologist crew members who participated in the 2010 field test.We document the procedures adopted for Desert RATS 2010 and report on our experiences regarding these protocols. Careful consideration must be made of various issues that impact the interplay between field geologic observations and sample collection, including time management; strategies relatedtoduplicationofsamplesandobservations;logisticalconstraintson the volume and mass of samples and the volume/transfer of data collected; and paradigms for evaluation of mission success. We find that the 2010 field protocols brought to light important aspects of each of these issues, and we recommend best practices and modifications to training and operational protocols to address them. Underlying our recommendations is the recognition that the capacity of the crew to flexibly execute their activities is paramount. Careful design of mission parameters, especially field geologic protocols, is critical for enabling the crews to successfully meet their science objectives.

Hurtado, Jose M., Jr.↗

Monodisperse Au11 Clusters Prepared by Soft Landing of Mass Selected Ions

Preparation of clean monodisperse samples of clusters and nanoparticles for characterization using cutting-edge analytical techniques is essential to understanding their size-dependent properties. Herein, we report a general method for the preparation of high surface coverage samples of monodisperse clusters containing an exact number of atoms. Polydisperse solutions of diphosphine-capped gold clusters were produced by reduction synthesis. Electrospray ionization was used to introduce the clusters into the gas phase where they were filtered by mass-tocharge ratio allowing clusters of a selected size to be deposited onto carbon coated copper grids at well controlled kinetic energies. Scanning transmission electron microscopy (STEM) analysis of the soft landed clusters confirms their monodispersity and high coverage on the substrate. The soft landing approach may be extended to other materials compatible with an array of available ionization techniques and, therefore, has widespread utility as a means for controlled preparation of monodisperse samples of nanoparticles and clusters for analysis by transmission electron microscopy (TEM)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Floodplain Assessment for the Middle Los Alamos Canyon Aggregate Area Investigations in Technical Area 02 at Los Alamos National Laboratory

The proposed action being assessed in this document occurs in TA-02 in the bottom of Los Alamos Canyon. The DOE proposes to conduct soil sampling at AOC 02-011 (d), AOC 02- 011(a)(ii), and SWMU 02-005, and excavate soils in AOC 02-011(a)(ii) as part of a corrective actions effort. Additional shallow surface soil samples (soil grab samples) will be collected throughout the TA-02 area, including within the floodplain, to perform ecotoxicology studies (Figures 1 and 2). The excavation boundaries in AOC 02-011(a)(ii) are slightly within the delineated 100-year floodplain. The project will use a variety of techniques for soil sampling and remediation efforts to include hand/digging, standard hand auger/sampling, excavation using machinery such as backhoe and front end loader and small drill rig. Heavy equipment will traverse the floodplain and spoils piles will be staged in the floodplain within developed or previously disturbed areas (e.g., existing paved roads and parking areas). The project will utilize and maintain appropriate best management practices (BMPs) to contain excavated materials, and all pollutants, including oil from machinery/vehicles. The project will stabilize disturbed areas as appropriate at the end of the project.

54 ENVIRONMENTAL SCIENCES↗

Monitor senses amount of contamination deposited on surfaces

Monitoring device detects and indicates directly the amount of contamination deposited on a surface. It uses an optical system in conjunction with a reliable collimated light source and associated electronics. Change in its output signal is proportional to change in the optical absorption characteristics of the sample plate surface.

Sheehy, R. N.↗

Multi-wavelength surface emitting quantum cascade laser based on equivalent phase shift

A novel surface emitting distributed feedback quantum cascade laser emitting around λ ∼ 4.6 μm is demonstrated by employing an equivalent phase shift (EPS) of quarter-wave (λ/4). The EPS is fabricated through extending one sampling period by 50% in the center of a sampled Bragg grating. Single-lobed far-field radiation pattern with a low divergence angle of about 0.6° × 16.8° is obtained. Selective single-mode lasing with a mean side mode suppression ratio above 20 dB and wavelength coverage range of 72 nm is achieved simultaneously on a single wafer only by changing the sampling period.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cation Data for the East River Watershed, Colorado (2014-2025)

This data package contains mean values for cation concentration for water samples taken from the East River Watershed in Colorado. Inductively coupled plasma mass spectrometry (ICP-MS) has been used to measure the concentrations of elements of interest simultaneously for the East River Watershed, Colorado groundwater and surface water samples to inform insights on the biogeochemistry processes within the watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. For samples collected prior to 06-16-2021, the instrumentation, Elan DRC II, PerkinElmer SCIEX, automatically switches among the three models necessary to analyze all 37 elements. These 37 elements include: (1) Lithium (Li), Beryllium (Be), Boron (B), Sodium (Na), Magnesium (Mg), Aluminium (Al), Silicon (Si), Phosphorus (P), Titanium (Ti), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Caesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th), Uranium (U) using standard model, argon Ar as reaction gas, (2) Potassium (K), Calcium (Ca), Vanadium (V), Chromium (Cr), Manganese (Mn), Iron (Fe) using dynamic reaction cell (DRC) model, ammonia NH3 as reaction gas, and (3) Phosphorus (P) and Selenium (Se) using DRC model, oxygen O2 as reaction gas. Note for the samples with higher concentrations of chloride (Cl-), asenic (As) concentrations were analysed with DRC model (oxygen O2 as reaction gas) to avoid the interference of chloride. For samples collected on and after 06-16-2021, an advanced Agilent 8900 triple quadrupole inductively coupled plasma mass spectrometry system (Agilent 8900 QQQ ICP-MS, Agilent Technologies) has been used to measure the concentrations of interested 36 elements simultaneously for environmental samples, including (1) Lithium (Li), Beryllium (Be) and Boron (B) using standard no gas mode, (2) Sodium (Na), Magnesium (Mg), Aluminium (Al) Phosphorus (P), Potassium (K), Chromium (Cr), Manganese (Mn), Iron (Fe), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Cesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th) and Uranium (U) using standard helium (He) collision mode, (3) Titanium (Ti) and Vanadium (V) using high Energy (HEHe) helium (He) collision mode, and (4) Silicon (Si), Calcium (Ca) and Selenium (Se) using standard H2 reaction mode. All samples were prepared/diluted with 2% (v/v) ultrapure nitric acid in Milli-Q water (18.2 mega ohm-cm), and analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (cation_data_2014_2025.zip) containing a total of 5,849 files: 5.848 data files of cation data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the detemination of Method Detection Limits (MDLs) for ICP-MS PerkinElmer DRC II instrumentation (Detemination_of_Method_Detection_Limits__MDLs__for_ICP_MS__PerkinElmer_Elan_DRC_II__LBL_Bldg74_Lab214D) for samples before November 2021; (5) PDF and docx files for the determination of MDLs for ICP-MS Agilent 8900 QQQ instrumentation (ICP_MS_Analysis_detection_limits_and_QA_QC_WenmingDong_updated_2026-08-06) for samples November 2021 and onward. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing cation data. Update on 2021-04-11: Added Detemination of Method Detection Limits (MDLs) for ICP-MS document, which can be accessed as a PDF or with Microsoft Word. Update on 2022-06-10: versioned updates to this dataset was made along with these changes: (1) updated cation data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) removed suffix and prefix on two variables (“aqberylliumion_asberyllium” and “aqlithiumion_aslithium”), (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-16. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Updated versions of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-06, of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Internal Energy Distributions of Ions Created by Electrospray Ionization and Laser Ablation-Liquid Vortex Capture-Electrospray Ionization

Recently a number of techniques have combined laser ablation with liquid capture for mass spectrometry spot sampling and imaging applications. The newly developed non-contact liquid-vortex capture probe has been used to efficiently collect 355 nm UV laser ablated material in a continuous flow solvent stream in which the captured material dissolves and then undergoes electrospray ionization. This sampling and ionization approach has produced what appear to be classic electrospray ionization spectra; however, the softness of this sampling/ionization process versus simple electrospray ionization has not been definitely determined. A series of benzlypyridinium salts, known as thermometer ions, were used to compare internal energy distributions between electrospray ionization and the UV laser ablation liquid-vortex capture probe electrospray combination. Measured internal energy distributions were identical between the two techniques, even with differences in laser fluence (0.7-3.1 J cm-2) and when using UV-absorbing or non-UV-absorbing sample substrates. This data indicates ions formed directly by UV laser ablation, if any, are likely an extremely small constituent of the total ion signal observed. Instead, neutral molecules, clusters or particulates ejected from the surface during laser ablation, subsequently captured and dissolved in the flowing solvent stream then electrosprayed are the predominant source of ion signal observed. The electrospray ionization process used controls the softness of the technique.