Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test Article”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Application of printed strain gauges in prototypical nuclear reactor conditions

This report discusses the current development and testing of additively manufactured temperature sensors and resistive/ capacitive strain gauges. This has potential to improve the sensor design and manufacturing techniques to meet the requirements of in-pile monitoring of mechanical properties and structural health of materials and specimens in current and advanced nuclear test reactors (i.e., in terms of environment conditions, sample geometry, and materials compatibility). The developmental additively manufactured strain gauges are exposed to separate effects testing (i.e., mechanical strain (up to 1000 µe), high temperature (up to 700 °C)) to determine environmental factors that affect the performance of the strain gauge. The robustness and integrity of a printed strain gauge layer exposed to a molten salt environment for up to 500 hours was evaluated, with the goal of assessing material compatibility of printed strain sensors for instrumented surveillance test articles in molten salt reactors. In addition, sensor qualification methodologies are further developed for determining the reliability and robustness at the interface of the additively manufactured strain gauge materials.

36 - MATERIALS SCIENCE↗

Development and Comparison of Ground and Satellite-based Retrievals of Cirrus Cloud Physical Properties

This report is the final update on ARM research conducted at DRI through May of 2006. A relatively minor amount of work was done after May, and last month (November), two journal papers partially funded by this project were published. The other investigator on this project, Dr. Bob d'Entremont, will be submitting his report in February 2007 when his no-cost extension expires. The main developments for this period, which concludes most of the DRI research on this project, are as follows: (1) Further development of a retrieval method for cirrus cloud ice particle effective diameter (De) and ice water path (IWP) using terrestrial radiances measured from satellites; (2) Revision and publication of the journal article 'Testing and Comparing the Modified Anomalous Diffraction Approximation'; and (3) Revision and publication of our radar retrieval method for IWC and snowfall rate.

54 ENVIRONMENTAL SCIENCES↗

Transducer Installation Effects on Pressure Measurements in PGC Devices

Pressure gain devices such as rotating detonation engines present an extremely harsh environment, generally precluding the use of any intrusive probe measurement. The most widely used diagnostic is the measurement of high frequency pressure which can be used to determine the pressure amplitude, number of waves and their direction and the wave structure. The preferred approach for making pressure measurements is to install the sensing element flush with the combustion chamber wall, but is almost always inhibited by the extremely high heat fluxes that can damage the sensor. Alternately, recessed cavity or infinite probe installation is seldom used for high frequency pressure measurements. While amplitude attenuation and phase distortion of the pressure signal can be introduced by these installation types, its characterization in the presence of high amplitude steep fronted pressure waves encountered in PGC devices has not been previously performed. In the current work a highly modular calibration test-bed is designed to enable characterization of pressure transducers based on their installation in the presence of steep fronted high amplitude pressure waves. Two transducer types, piezoelectric PCB® 113B26 and water-cooled piezoresistive Kulite®WCT-312M were used and installed in the flush, recessed cavity and infinite tube probe configuration. The recessed cavity probe showed 5-26% amplitude attenuation and almost negligible time lag compared to the flush transducer, the infinite tube pressure (ITP) transducer showed a significantly higher delay and as much as 50% reduction in measured pressure amplitude. Secondary wave features from reflections within the test article, that were captured by the flush and recessed cavity transducer were damped by the infinite probe measurement.

20 FOSSIL-FUELED POWER PLANTS↗

Liquid crystals detect voids in fiber glass laminates

Liquid crystal solution nondestructively detects voids or poor bond lines in fiber glass laminates. A thin coating of the solution is applied by spray or brush to the test article surface, and when heated indicates the exact location of defects by differences in color.

Hollar, W. T.↗

Analysis of a Hot Elevon Structure

Comparison of ASKA and NASTRAN programs analyses of space shuttle hot elevon test article deformed under thermal and mechanical loads

Bergmann, H. W.↗

Titanium reinforced boron-polyimide composite

Processing techniques for boron polyimide prepreg were developed whereby composites could be molded under vacuum bag pressure only. A post-cure cycle was developed which resulted in no loss in room temperature mechanical properties of the composite at any time during up to 16 hours at 650 F. A design utilizing laminated titanium foil was developed to achieve a smooth transition of load from the titanium attachment points into the boron-reinforced body of the structure. The box beam test article was subjected to combined bending and torsional loads while exposed to 650 F. Loads were applied incrementally until failure occurred at 83% design limit load.

Clark, G. A.↗

Directional molecular flow analysis and leak detection with a rotatable gas analyzer in a large space simulation chamber

A system was developed and applied at the NASA Manned Spacecraft Center for measuring and analyzing directional molecular flows in a large thermal vacuum chamber in order to verify molecular environment and identify characteristic and abnormal test article and chamber conditions. The system is described, and some results obtained in over 1200 hours of operation are given.

Ehlers, H. K. F.↗

Structural evaluation of candidate space shuttle thermal protection systems

The characteristics and development of a lightweight reusable thermal protection system for the space shuttle are discussed. The test articles consisted of metallic substrates with upper surfaces covered with all-silica, reusable, surface insulation material. The material is processed in the form of tiles. The external surfaces of the tiles are provided with a coating system which consists of a borosilicate coating with a silicon carbide emittance agent and impregnation with a hydrophobic agent. The finished tiles are attached to the metal substrate by adhesive bonding. Charts and graphs of the properties of the material are provided.

Burns, A. B.↗

Test facility for 6000 hour life test of 30 cm mercury ion thruster

The environmental and instrumentation requirements for long term testing of electrical propulsion thrusters which impose severe and unusual requirements upon the simulation facility were studied. High speed ions ejected from a mercury thruster erode material from collecting surfaces, which is then scattered and redeposited upon other surfaces, with resultant damage to the chamber and test article. By collecting the thruster plume on a frozen mercury surface damage to the thruster and chamber by back-scattered erosion products was minimized. Provisions for unattended operation, remote data acquisition, personnel safety, and instrumentation for assessing thruster performance are also discussed.

Caldwell, J. J.↗

Program for establishing long-time flight service performance of composite materials in the center wing structure of C-130 aircraft. Phase 3: Fabrication

The manufacturing plan for three C-130 aircraft center wing box test articles, selectively reinforced with boron-epoxy composites, is outlined for the following tasks: (1) tooling; (2) metal parts fabrication: (3) reinforcing laminate fabrication; (4) laminate-to-metal parts bonding; and (5) wing box assembly. The criteria used for reliability and quality assurance are discussed, and several solutions to specific manufacturing problems encountered during fabrication are given. For Vol. 1, see N73-13011; for Vol. 2, see N73-22929.

Harvill, W. E.↗

An automatic data system for vibration modal tuning and evaluation

A digitally based automatic modal tuning and analysis system developed to provide an operational capability beginning at 0.1 hertz is described. The elements of the system, which provides unique control features, maximum operator visibility, and rapid data reduction and documentation, are briefly described; and the operational flow is discussed to illustrate the full range of capabilities and the flexibility of application. The successful application of the system to a modal survey of the Skylab payload is described. Information about the Skylab test article, coincident-quadrature analysis of modal response data, orthogonality, and damping calculations is included in the appendixes. Recommendations for future application of the system are also made.

Salyer, R. A.↗

A leading edge heating array and a flat surface heating array: Final design

A heating array is described for testing full-scale sections of the leading edge and lower fuselage surfaces of the shuttle. The heating array was designed to provide a tool for development and acceptance testing of leading edge segments and large flat sections of the main body thermal protection system. The array was designed using a variable length module concept to meet test requirements using interchangeable components from one test configuration in another configuration. Heat generating modules and heat absorbing modules were employed to achieve the thermal gradient around the leading edge. A support was developed to hold the modules to form an envelope around a variety of leading edges; to supply coolant to each module; the support structure and to hold the modules in the flat surface heater configuration. An optical pyrometer system mounted within the array was designed to monitor specimen surface temperatures without altering the test article's surface.

Source record↗

Shuttle LOX loading transient study. Task 2 milestone report. National space and technology laboratories (NSTL) LOX loading facility analysis

Transient thermodynamic analyses were made of the LOX loading system proposed for the space shuttle main propulsion test article (MPTA). This system is made up of a LOX replenish system and a main LOX line which include the barge tank, the lines, pumps, and valves between the barge and the orbiter (ORB) ground service equipment (GSE) interface, the MPTA fill system, the space shuttle main engine (SSME) chilldown bleed system, and the GSE vent system. System analyses include predictions of system performance sensitivity to operating sequence and LOX flowrate, temperature, and quality at the ORB/GSE interface. The transient thermodynamic conditions at the SSME feed line entrance, ET entrance (tank bottom), and the SSME bleed/GSE vent TEE are also included. The analyses are based on continuous SSME bleed flow during GSE facility chilldown.

Glasgow, V. L.↗

Shuttle LOX Loading Transient Study

The configuration and operation of the LOX loading facilities to be used for the space shuttle main propulsion test article at the National Space and Technology Laboratories (NSTL), and for the space shuttle launch facilities at John F. Kennedy Space Center (KSC) was investigated. The acceptability of these LOX loading facilities for each application was determined along with the degree of similarity between the systems with respect to the applicability of data developed during operations at NSTL a to the launch site operations at KSC. Results are summarized and final data comparisons, conclusions, and recommendations are presented.

Glasgow, V. L.↗

Improved radiant-heat oven

Greatly improved oven materially increases lamp life by using a new reflector arrangement. Entire unit uses less power, yet heats test articles to higher temperatures with lower cooling requirements than previous ovens. Improved design offers significant savings in costs and energy.

Beckerle, L. D.↗

Outdoor tests of a liquid solar collector

Results of outdoor test program evaluating thermal performance of liquid solar collector are presented in report. Test article used is flatplate collector with antifreeze solution as working fluid.

Source record↗