Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve

To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an innovative high-temperature chloride molten salt valve, with operation up to 750°C. This valve is intended to be employed within Gen 3 CSP liquid-based thermal energy storage (TES) systems as well as Gen 4 modular salt reactor (MSR) technologies. This work details the general design and flow testing of a bellows-seal flow control valve (FCV). This design includes an integrated closed-loop thermal control system to ensure robust design for freeze-thaw cycles. The self-contained thermal management STM system, is unique in the salt valve industry since it is an integrated solution to provide a consistent, repeatable alternative to typical heat tracing. Additionally, the design includes the employment of a novel heat pipe valve stem to facilitate enhanced passive thermal management into the valve assembly. This valve stem heat pipe is designed to facilitate natural circulation within the bonnet to ensure robust operation, during both nominal and transient thermal operation. The valve body and trim will be designed using SS316H, consistent with Flowserve Corporation’s existing product base and is code qualified but will utilize clad material for materials corrosion, manufacturing cost reduction and compatibility to ensure design flexibility. A test campaign was performed in this investigation utilizing a novel 750°C ternary chloride (20%NaCl/40%MgCl2/40%KCl by mol. wt. %) molten salt flow loop. A discussion about the design and installation of the valves within this test bed is provided for this investigation. Valve test results from this study assessed Cv curves as well as multiple actuator cycles, under varying thermodynamic and operational mode conditions, which would be characteristic within a commercial molten salt facility. The results indicate nominal operation for the baseline design, though improved performance and reliability is expected with the full designed FCV.

Armijo, Kenneth (ORCID:0000000346832147)↗

Fabrication and Test of C3a: A Six-Layer Subscale Canted $\cos \theta$ Dipole Magnet Using High-Temperature Superconducting corc Wires

REBCO coated conductors have a strong potential for high-field magnet applications. The REBCO technology, however, is still in its infancy for accelerator magnet applications. As part of the U.S. Magnet Development Program (MDP), we developed a six-layer canted cos θ dipole magnet, C3a, using CORC® wires developed by Advanced Conductor Technologies LLC. All the layers were wound using a semi-automated winding machine. Three layers of the magnet used CORC® wires containing the SuperPower “AP” REBCO tapes and the remaining layers used the wires containing the “HM” tapes. At 77 K, both kinds of CORC® wires showed 5% to 10% degradation, after bending to a minimum bend radius of 30 or 35 mm, with respect to the self-field critical current measured before winding. At 4.2 K, the magnet reached 9.5 kA at a ramp rate of 9 A s -1 and generated a dipole field of 1.4 T. Further, the critical current of one layer degraded by 4% after a current transient up to 10.5 kA ramped in an averaged rate of 175 kA s -1 or 20 T s -1 . We confirmed the HM CORC® wire can carry a higher current than the AP CORC® wire at 4.2 K. The test results of the C3a magnet showed that the fabrication and assembly procedure can be used for the upcoming full-scale C3 magnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detecting self-ion irradiation-induced void swelling in pure copper using transient grating spectroscopy

Irradiation-induced void swelling remains a major challenge to nuclear reactor operation. Swelling may take years to initiate and often results in rapid material property degradation once started. Alloy development for advanced nuclear systems will require rapid characterization of the swelling breakaway dose in new alloys, yet this capability does not yet exist. In this paper, we demonstrate that transient grating spectroscopy (TGS) can detect void swelling in single crystal copper via changes in surface acoustic wave (SAW) velocity. Scanning transmission electron microscopy (STEM) links the TGS-observed changes with void swelling-induced microstructural evolution. Finally, these results are considered in the context of previous work to suggest that in situ TGS will be able to rapidly determine when new bulk materials begin void swelling, shortening alloy development and testing times.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Passive wick fluxmeters: Design considerations and field applications

Optimization of water use in agriculture and quantification of leachate losses from landfills and watersheds require reliable estimates of vadose-zone water fluxes. Current technology is limited primarily to lysimeters, which directly measure water flux but may in some way disrupt flow, causing errors in the measured drainage. We report on design considerations and field tests of passive-wick lysimeters (fluxmeters) that use a control tube to minimize convergent or divergent flow. Design calculations with a quasi-three-dimensional model illustrate how convergence and divergence can be minimized for a range of soil and climatic conditions under steady-state and transient fluxes using control tubes of varying heights. There exists a critical recharge rate for a given wick length, where the recharge is 100% regardless of height of the control tube. Otherwise, convergent or divergent flow will occur, especially when the control tube height is small. While divergence is eliminated in coarse soils using control tubes, it is reduced but not eliminated in finer soils, particularly for flux rates < 100 mm/yr. Passive-wick fluxmeters with 60-cm high control tubes and 60-cm long wicks were tested in soils ranging from non-vegetated semi-arid settings in the USA to grasslands in Germany and rain-fed crops in New Zealand and the South Pacific. Where side-by-side comparisons of drainage were made between passive-wick fluxmeters and conventional lysimeters in the USA and Germany, agreement was very good. In semi-arid settings, drainage was found to depend upon precipitation distribution, surface soil, topographic relief, and the type and amount of vegetation. In Washington State, USA, soil texture dominated all factors controlling drainage from test landfill covers. As expected, drainage was greatest (> 60% annual precipitation) from gravel surfaces and least (no drainage) from silt loam soils. In Oregon and New Mexico, USA, and in New Zealand, drainage showed substantial spatial variability. The New Mexico tests were located in semiarid canyon bottom terraces, with flash flood prone locations having extremely high drainage/precipitation ratios. In the wettest environments, drainage was found to be closely linked to rate and duration of precipitation events.

54 ENVIRONMENTAL SCIENCES↗

A time-domain electromechanical co-simulation framework for power system transient analysis with retainment of user defined models

This paper proposes a time-domain electromechanical co-simulation framework to accomplish concurrent running of multiple simulators in order to preserve user-defined models and allow maximum simulation accuracy for power system transient analysis. Here, a middleware interface is developed to manage the interaction and synchronization of the multiple simulators via boundary model. Consequently, it eliminates the requirement of model conversion of each subsystem and thus ensure the user-defined models in each specific software are retained for entire system situational awareness. Preliminary testing results on 140-bus Northeastern Power Coordinating Council (NPCC) model validate the effectiveness and accuracy of the proposed framework for PSS/E and PSLF co-simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment and Performance of Flexible Quench Antenna Array Diagnostics for Superconducting Magnets

FNAL has been developing multiple versions of flexible quench antennas (flex-QA), including some specially optimized for high sensitivity and/or high resolution, to characterize quench events and transients during current ramping in superconducting magnets. A fundamental feature in our use of these is the creation of grid-like structures of sensitive elements to cover coil surfaces, with the aim of getting precise localization of magnetic flux-change events. The flex-QA are coupled with fast data-acquisition, allowing comprehensive analysis of signals at the relevant fine time scales. In addition to arrays of various flex-QA types being used during cryogenic testing of superconducting magnets, we also are utilizing a newly developed room temperature test stand to better understand QA response characteristics. The data from actual superconducting magnet tests, warm test stand measurements, and simulation data on the same QA designs allows us to draw conclusions on operational feasibility and plan better for improvements of our sensors. In this paper we present data from the multiple tests performed and analysis results. Flex-QA designs are compared, and their features, options, and optimization discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Incompatibility of Contrast Medium and Trisodium Citrate

To test the compatibility of trisodium citrate, a catheter lock solution, with iodinated contrast medium. Iohexol, iobitridol, iodixanol, ioxaglate, ioxithalamate, iomeprol, and iopromide were tested. In all tests, 2 ml of contrast medium were mixed with 2 ml of trisodium citrate solution. Iodixanol and ioxaglate provoked a highly viscous gluelike precipitation when mixed with trisodium citrate. A brief transient precipitate was observed with iohexol, iomeprol, and ioxithalamate. Permanent precipitation occurred with iobitridol and iopromide. One must be aware of the potential for precipitation when contrast medium is mixed with trisodium citrate solution. Before trisodium citrate solution is injected, the catheter should be thoroughly flushed with saline if a contrast medium has previously been injected through it.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Variational, stable, and self-consistent coupling of 3D electromagnetics to 1D transmission lines in the time domain

This work presents a new multiscale method for coupling the 3D Maxwell's equations to the 1D telegrapher's equations. While Maxwell's equations are appropriate for modeling complex electromagnetics in arbitrary-geometry domains, simulation cost for many applications (e.g. pulsed power) can be dramatically reduced by representing less complex transmission line regions of the domain with a 1D model. By assuming a transverse electromagnetic (TEM) ansatz for the solution in a transmission line region, we reduce the Maxwell's equations to the telegrapher's equations. Here, we propose a self-consistent finite element formulation of the fully coupled system that uses boundary integrals to couple between the 3D and 1D domains and supports arbitrary unstructured 3D meshes. Additionally, by using a Lagrange multiplier to enforce continuity at the coupling interface, we allow for an absorbing boundary condition to also be applied to non-TEM modes on this boundary. We demonstrate that this feature reduces non-physical reflection and ringing of non-TEM modes off of the coupling boundary. By employing implicit time integration, we ensure a stable coupling, and we introduce an efficient method for solving the resulting linear systems. We demonstrate the accuracy of the new method on two verification problems, a transient O-wave in a rectilinear prism and a steady-state problem in a coaxial geometry, and show the efficiency and weak scalability of our implementation on a cold test of the Z-machine MITL and post-hole convolute.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fabrication and testing of a 4-node micro-pocket fission detector array for the Kansas State University TRIGA Mk. II research nuclear reactor

Advancements in nuclear reactor core modeling and computational capability have encouraged further development of in-core neutron sensors. Micro-Pocket Fission Detectors (MPFDs) have been fabricated and tested previously, but successful testing of these prior detectors was limited to single-node operation with specialized designs. Described in this work is a modular, four-node MPFD array fabricated and tested at Kansas State University (KSU). The four sensor nodes were equally spaced to span the length of the fuel-region of the KSU TRIGA Mk. II research nuclear reactor core. The encapsulated array was filled with argon gas, serving as an ionization medium in the small cavities of the MPFDs. The unified design improved device ruggedness and simplified construction over previous designs. A 0.315-in. (8-mm) penetration in the upper grid plate of the KSU TRIGA Mk. II research nuclear reactor was used to deploy the array between fuel elements in the core. The MPFD array was coupled to an electronic support system which has been developed to support pulse-mode operation. Neutron-induced pulses were observed on all four sensor channels. Stable device operation was confirmed by testing under steady-state reactor conditions. Each of the four sensors in the array responded to changes in reactor power between 10 kWth and full power (750 kWth). Reactor power transients were observed in real-time including positive transients with periods of 5, 15, and 30 s. Manual reactor power oscillations were observed in real-time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Parasitic Capacitors' Impact on Switching Performance in a 10 kV SiC MOSFET Based Converter

In a converter based on 10 kV SiC MOSFETs, major sources of parasitic capacitance are the anti-parallel junction barrier schottky (JBS) diode, heat sink, and load inductor. A half bridge phase leg test setup is built to investigate these parasitic capacitors’ impact on the switching performance at 6.25 kV. Generally these parasitic capacitors slows down both turn-on and turn-off transient and can cause significant increase in switching energy loss. The impact of the parasitic capacitor in the load inductor is analyzed, which has either very short wire or long wire in series. Switching performance of the phase leg with two different thermal designs are compared to investigate the impact of the parasitic capacitor due to the heat sink. The large parasitic capacitor due to the large drain plate of discrete 10 kV SiC MOSFET for heat dissipation can result in 44.5% increase in switching energy loss at low load current.

Huang, Xingxuan↗

Heavy-Duty Nonroad Material Handler Electrification Part 1: Real-World Drive Cycle Development

Knowing a detailed operating cycle is critical for developing and testing equipment. Operating cycles can be separated by two clear distinctions: (1) regulatory or non-regulatory and (2) application at the engine-only or full machine level. The Environmental Protection Agency’s (EPA) Nonroad Transient Cycle (NRTC) may be a good representation of engine use in many types of equipment, but there is a gap in standardized and validated drive cycles specifically for nonroad material handlers. Lacking a standardized drive cycle makes it difficult to accurately benchmark machine performance and validate new powertrain technologies. The objective of this investigation is to illustrate the development of a custom drive cycle augmented with real-world customer use data that serves multiple purposes: (1) understand the range of operation and utilization that formulated inputs for electrified architecture analysis and (2) develop a repetitive and consistent maneuver to establish baseline energy consumption enabling equivalent comparison to future electrified prototype builds. This article presents a solution specifically for a 23-ton nonroad material handler in which material handling, machine transport, and extended idle were homologated to form representative short cycles defined by machine velocity and hydraulic cylinder position. The most intensive material handling short cycles had a load factor of 40% and an average fuel rate of 16 L/h. Combined with a visual aid, the short cycles exhibited low variability, having less than 5% root mean square (RMS) error in lift and reach position with respect to the average. The machine’s performance on these short cycles at the Advanced Power Systems Research Center (APSRC) was compared to results from two real-world customer locations operating the instrumented test machine in a cyclical manner, and for similar ground conditions were found to be comparable in fuel consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Framework for Bulk Electric Grid Impacts from HEMP E1 and E3 Effects (Tasks 3.1 Final Report)

This report presents a framework to evaluate the impact of a high-altitude electromagnetic pulse (HEMP) event on a bulk electric power grid. This report limits itself to modeling the impact of EMP E1 and E3 components. The co-simulation of E1 and E3 is presented in detail, and the focus of the paper is on the framework rather than actual results. This approach is highly conservative as E1 and E3 are not maximized with the same event characteristics and may only slightly overlap. The actual results shown in this report are based on a synthetic grid with synthetic data and a limited exemplary EMP model. The framework presented can be leveraged and used to analyze the impact of other threat scenarios, both manmade and natural disasters. This report d escribes a Monte-Carlo based methodology to probabilistically quantify the transient response of the power grid to a HEMP event. The approach uses multiple fundamental steps to characterize the system response to HEMP events, focused on the E1 and E3 components of the event. 1) Obtain component failure data related to HEMP events testing of components and creating component failure models. Use the component failure model to create component failure conditional probability density function (PDF) that is a function of the HEMP induced terminal voltage. 2) Model HEMP scenarios and calculate the E1 coupled voltage profiles seen by all system components. Model the same HEMP scenarios and calculate the transformer reactive power consumption profiles due to E3. 3) Sample each component failure PDF to determine which grid components will fail, due to the E1 voltage spike, for each scenario. 4) Perform dynamic simulations that incorporate the predicted component failures from E1 and reactive power consumption at each transformer affected by E3. These simulations allow for secondary transients to affect the relays/protection remaining in service which can lead to cascading outages. 5) Identify the locations and amount of load lost for each scenario through grid dynamic simulation. This can be an indication of the immediate grid impacts from a HEMP event. In addition, perform more detailed analysis to determine critical nodes and system trends. 6) To help realize the longer-term impacts, a security constrained alternating current optimal power flow (ACOPF) is run to maximize critical load served. This report describes a modeling framework to assess the systemic grid impacts due to a HEMP event. This stochastic simulation framework generates a large amount of data for each Monte Carlo replication, including HEMP location and characteristics, relay and component failures, E3 GIC profiles, cascading dynamics including voltage and frequency over time, and final system state. This data can then be analyzed to identify trends, e.g., unique system behavior modes or critical components whose failure is more likely to cause serious systemic effects. The proposed analysis process is demonstrated on a representative system. In order to draw realistic conclusions of the impact of a HEMP event on the grid, a significant amount of work remains with respect to modeling the impact on various grid components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low Temperature Combustion Demonstrator for High Efficiency Clean Combustion

The project which extended from November 2005 to May of 2010 demonstrated the application of Low Temperature Combustion (LTC) with engine out NOx levels of 0.2 g/bhp-hr throughout the program target load of 12.6bar BMEP. The project showed that the range of loads could be extended to 16.5bar BMEP, therefore matching the reference lug line of the base 2007 MY Navistar 6.4L V8 engine. Results showed that the application of LTC provided a dramatic improvement over engine out emissions when compared to the base engine. Furthermore LTC improved thermal efficiency by over 5% from the base production engine when using the steady state 13 mode composite test as a benchmark. The key enablers included improvements in the air, fuel injection, and cooling systems made in Phases I and II. The outcome was the product of a careful integration of each component under an intelligent control system. The engine hardware provided the conditions to support LTC and the controller provided the necessary robustness for a stable combustion. Phase III provided a detailed account on the injection strategy used to meet the high load requirements. During this phase, the control strategy was implemented in a production automotive grade ECU to perform cycle-by-cycle combustion feedback on each of the engine cylinders. The control interacted on a cycle base with the injection system and with the Turbo-EGR systems according to their respective time constants. The result was a unique system that could, first, help optimize the combustion system and maintain high efficiency, and secondly, extend the steady state results to the transient mode of operation. The engine was upgraded in Phase IV with a Variable Valve Actuation system and a hybrid EGR loop. The impact of the more versatile EGR loop did not provide significant advantages, however the application of VVA proved to be an enabler to further extend the operation of LTC and gain considerable benefits in fuel economy and soot reduction. Finally, the transient demonstration was performed in Phase IV. The project demonstrated the achievement of meeting US10 emissions without NOx aftertreatment. The successful execution of the project has served to highlight the effectiveness of closely matched combustion predictive tools to engine testing. It has further served to highlight the importance of key technologies and future areas of research and development. In this regard, recommendations are made towards further improvements in the areas of engine hardware, fuel injection systems, controls and fuels.

33 ADVANCED PROPULSION SYSTEMS↗

Direct extraction of intense-field-induced polarization in the continuum on the attosecond time scale from transient absorption

Here, a procedure is suggested for using transient absorption spectroscopy above the ionization threshold to measure the polarization of the continuum induced by an intense optical pulse. In this way transient absorption measurement can be used to probe subfemtosecond intense field dynamics in atoms and molecules. The method is based on an approximation to the dependence of these spectra on time delay between an attosecond XUV probe pulse and an intense pump pulse that is tested over a wide range of intensities and time delays by all-electrons-active calculations using the multiconfiguration time-dependent Hartree-Fock method in the case of neon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Explaining Nonmerger Gamma-Ray Bursts and Broad-lined Supernovae with Close Binary Progenitors with Black Hole Central Engines

For over 25 yr, the origin of long-duration gamma-ray bursts (lGRBs) has been linked to the collapse of rotating massive stars. However, we have yet to pinpoint the stellar progenitor powering these transients. Moreover, the dominant engine powering the explosions remains open to debate. Observations of both lGRBs, supernovae associated with these GRBs, such as broad-line (BL) stripped-envelope (type Ic) supernovae (hereafter, Ic-BL), supernovae (SNe), and perhaps superluminous SNe, fast blue optical transients, and fast x-ray transients, may provide clues to both engines and progenitors. In this paper, we conduct a detailed study of the tight-binary formation scenario for lGRBs, comparing this scenario to other leading progenitor models. Combining this progenitor scenario with different lGRB engines, we can compare to existing data and make predictions for future observational tests. We find that the combination of the tight-binary progenitor scenario with the black hole accretion disk engine can explain lGRBs, low-luminosity GRBs, ultra-long GRBs, and Ic-BL. We discuss the various progenitor properties required for these different subclasses and note such systems would be future gravitational-wave merger sources. We show that the current literature on other progenitor-engine scenarios cannot explain all of these transient classes with a single origin, motivating additional work. We find that the tight-binary progenitor with a magnetar engine is excluded by existing observations. The observations can be used to constrain the properties of stellar evolution, the nature of the GRB, and the associated SN engines in lGRBs and Ic-BL. We discuss the future observations needed to constrain our understanding of these rare, but powerful, explosions.

79 ASTRONOMY AND ASTROPHYSICS↗

Photometric classification of Hyper Suprime-Cam transients using machine learning

Abstract The advancement of technology has resulted in a rapid increase in supernova (SN) discoveries. The Subaru/Hyper Suprime-Cam (HSC) transient survey, conducted from fall 2016 through spring 2017, yielded 1824 SN candidates. This gave rise to the need for fast type classification for spectroscopic follow-up and prompted us to develop a machine learning algorithm using a deep neural network with highway layers. This algorithm is trained by actual observed cadence and filter combinations such that we can directly input the observed data array without any interpretation. We tested our model with a dataset from the LSST classification challenge (Deep Drilling Field). Our classifier scores an area under the curve (AUC) of 0.996 for binary classification (SN Ia or non-SN Ia) and 95.3% accuracy for three-class classification (SN Ia, SN Ibc, or SN II). Application of our binary classification to HSC transient data yields an AUC score of 0.925. With two weeks of HSC data since the first detection, this classifier achieves 78.1% accuracy for binary classification, and the accuracy increases to 84.2% with the full dataset. This paper discusses the potential use of machine learning for SN type classification purposes.

Takahashi, Ichiro↗

GPHS Module Pre-Impact test Temperature Prediction with ANSYS [PowerPoint]

The purpose of the project was to: Develop a finite element thermal model of the General Purpose Heat Source (GPHS) Module loaded with four fueled clads; Perform steady state analysis to validate the thermal model via energy balance; Perform transient thermal analysis to predict clad temperatures at various times; and, Transient model results will be used to inform module soak time needed to reach a desired clad temperature prior to impact.

42 ENGINEERING↗