Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Some remarks on waves in the solar wind

Waves are significant to the solar wind in two ways as modifiers of the particle distribution functions, and as diagnostics. In addition, the solar wind serves as an important laboratory for the study of plasma wave processes, as it is possible to make detailed measurements of phenomena which are too small to be easily measured by laboratory sized sensors. There are two areas where waves (we include discontinuities under this heading) must make important modifications of the distribution functions: in accelerating the alpha particles to higher speeds than the protons (Marsch et al.) and in accelerating the solar wind itself. A third area is possibly in maintaining the relative isotropy of the solar wind ion distribution in the solar wind rest frame. As the solar wind is nearly collisionless, the ions should conserve magnetic moment in rushing out from the sun, and therefore Tperp/B should be relatively constant, but it is obviously not. This has not received much attention. The waves, both electromagnetic and electrostatic, which are pan of the solar Type 111 burst phenomenon, have been extensively studied as examples of nonlinear plasma phenomena, and also used as remote sensors to trace the solar magnetic field. The observations made by Ulysses show that the field can be traced in this way out to perhaps a little more than an A.U., but then the electromagnetic pan of the type 111 burst fades out. Nevertheless, sometimes Langmuir waves appear at Ulysses at an appropriate extrapolated time. This seems to support the picture in which the electromagnetic waves at the fundamental plasma frequency are trapped in density fluctuations. Langmuir waves in the solar wind are usually in quasi-thermal equilibrium quasi because the solar wind itself is not isothermal. The Observatory of Paris group (Steinberg. Meyer-Vernet, Hoang) has exploited this with an experiment on WIND which is capable of providing density and temperature on a faster time scale than hitherto. Recently it has been found that Langmuir waves are associated with magnetic holes. This may help to elucidate the nature of magnetic holes. Nonlinear processes are important in the transformation of wave energy to panicle energy. Some recent examples from WIND data will be shown.

Kellogg, Paul J.↗

The ALI-ARMS Code for Modeling Atmospheric non-LTE Molecular Band Emissions: Current Status and Applications

The Accelerated Lambda Iteration (ALI) technique was developed in stellar astrophysics at the beginning of 1990s for solving the non-LTE radiative transfer problem in atomic lines and multiplets in stellar atmospheres. It was later successfully applied to modeling the non-LTE emissions and radiative cooling/heating in the vibrational-rotational bands of molecules in planetary atmospheres. Similar to the standard lambda iterations ALI operates with the matrices of minimal dimension. However, it provides higher convergence rate and stability due to removing from the iterating process the photons trapped in the optically thick line cores. In the current ALI-ARMS (ALI for Atmospheric Radiation and Molecular Spectra) code version additional acceleration of calculations is provided by utilizing the opacity distribution function (ODF) approach and "decoupling". The former allows replacing the band branches by single lines of special shape, whereas the latter treats non-linearity caused by strong near-resonant vibration-vibrational level coupling without additional linearizing the statistical equilibrium equations. Latest code application for the non-LTE diagnostics of the molecular band emissions of Earth's and Martian atmospheres as well as for the non-LTE IR cooling/heating calculations are discussed.

Kutepov, A. A.↗

Injector for scattering measurements on fully solvated biospecies

We describe a liquid jet injector system developed to deliver fully solvated microscopic target species into a probe beam under either vacuum or ambient conditions. The injector was designed specifically for x-ray scattering studies of biological nanospecies using x-ray free electron lasers and third generation synchrotrons, but is of interest to any application in which microscopic samples must be delivered in a fully solvated state and with microscopic precision. By utilizing a gas dynamic virtual nozzle (GDVN) to generate a sample-containing liquid jet of diameter ranging from 300 nm to 20 {mu}m, the injector avoids the clogging problems associated in this size range with conventional Rayleigh jets. A differential pumping system incorporated into the injector shields the experimental chamber from the gas load of the GDVN, making the injector compatible with high vacuum systems. The injector houses a fiber-optically coupled pump laser to illuminate the jet for pump-probe experiments and a hermetically sealed microscope to observe the liquid jet for diagnostics and alignment during operation. This injector system has now been used during several experimental runs at the Linac Coherent Light Source. Recent refinements in GDVN design are also presented.

43 PARTICLE ACCELERATORS↗

Coherent electron cooling proof of principle instrumentation design

The goal of the Coherent Electron Cooling Proof-of-Principle (CeC PoP) experiment being designed at RHIC is to demonstrate longitudinal (energy spread) cooling before the expected CD-2 for eRHIC. The scope of the experiment is to longitudinally cool a single bunch of 40 GeV/u gold ions in RHIC. This paper will describe the instrumentation systems proposed to meet the diagnostics challenges. These include measurements of beam intensity, emittance, energy spread, bunch length, position, orbit stability, and transverse and temporal alignment of electron and ion beams.

43 PARTICLE ACCELERATORS↗

Electron Beam Diagnostics Of The JLAB UV FEL

In this contribution we describe various systems and aspects of the electron beam diagnostics of the JLab UV FEL. The FEL is installed on a new bypass beam line at the existing 10 kW IR Upgrade FEL. Here, we describe a set of the following systems. A combination of OTR and phosphor viewers is used for measurements of the transverse beam profile, transverse emittance, and Twiss parameters. This system is also used for alignment of the optical cavity of the UV oscillator and to ensure the overlap between the electron beam and optical mode in the FEL wiggler. A system of beam position monitors equipped with log-amp based BPM electronics. Bunch length on the order of 120 fs RMS is measured with the help of a modified Martin-Puplett interferometer. The longitudinal transfer function measurement system is used to set up bunch compression in an optimal way, such that the LINAC RF curvature is compensated using only higher order magnetic elements of the beam transport. This set of diagnostic systems made a significant contribution in achieving first lasing of the FEL after only about 60 hours of beam operation.

43 PARTICLE ACCELERATORS↗

Power Module Precursors and Prognostics

This project focuses on finding and utilizing electrical properties (precursors) of power electronic devices and modules whose changes have strong correlations with different modes and levels of degradations in order to realize online and lightweight state of health evaluation and fault diagnosis. Results from this project will contribute to higher safety, reliability, and power density of power electronic components. The approaches mainly include reviewing academic literature and industry practices for state of the art precursor identification and extraction, accelerated life cycles (ALC) of various power modules to create different degradations in-house, and developing techniques for gate-driver-integratable precursor detection circuit. In FY24, the results includes two sets of definitively detected aging precursors (on-state resistance and gate threshold voltage) for two sets of power modules respectively, controlled accelerated lifetime cycling of multiple silicon carbide (SiC) metal-oxide-semiconductor field-effect transistor (MOSFET) modules, and the development and validation of a gate voltage detection system.

ADVANCED PROPULSION SYSTEMS↗

Mitigation Plans for the Microbunching-Instability-Related COTR at ASTA/FNAL

At the Advanced Superconducting Test Accelerator (ASTA) now under construction at Fermilab, we anticipate the appearance of the microbunching instability related to the longitudinal space charge (LSC) impedances. With a photoinjector source and up to two chicane compressors planned, the conditions should result in the shift of some microbunched features into the visible light regime. The presence of longitudinal microstructures (microbunching) in the electron beam or the leading edge spikes can result in strong, spatially localized coherent enhancements of optical transition radiation (COTR) that mask the actual beam profile. Several efforts on mitigation of the effects in the diagnostics task have been identified. At ASTA we have designed the beam profiling stations to have mitigation features based on spectral filtering, scintillator choice, and the timing of the trigger to the digital camera's CCD chip. Since the COTR is more intense in the NIR than UV we have selectable bandpass filters centered at 420 nm which also overlap the spectral emissions of the LYSO:Ce scintillators. By delaying the CCD trigger timing of the integration window by 40-50 ns, we can reject the prompt OTR signal and integrate on the delayed scintillator light predominately. This combination of options should allow mitigation of COTR enhancements of order 100-1000 in the distribution.

43 PARTICLE ACCELERATORS↗

Microwave ECR plasma electron flood for low pressure wafer charge neutralization

Modern ion implanters typically use dc arc discharge Plasma Electron Floods (PEFs) to neutralize wafer charge. The arc discharge requires using at least some refractory metal hardware, e.g. a thermionically emitting filament, which can be undesirable in applications where no metallic contamination is critical. rf discharge PEFs have been proposed to mitigate contamination risks but the gas flows required can result in high process chamber pressures. Axcelis has developed a microwave electron cyclotron resonance (ECR) PEF to provide refractory metals contamination-free wafer neutralization with low gas flow requirement. Our PEF uses a custom, reentrant cusp magnet field providing ECR and superior electron confinement. Stable PEF operation with extraction slits sized for 300 mm wafers can be attained at Xe gas flows lower than 0.2 sccm. Electron extraction currents can be as high as 20 mA at absorbed microwave powers < 70 W. On Axcelis' new medium current implanter, plasma generation has proven robust against pressure transients caused by, for example, photoresist outgassing by high power ion beams. Charge monitor and floating potential measurements along the wafer surface corroborate adequate wafer charge neutralization for low energy, high current ion beams.

43 PARTICLE ACCELERATORS↗

High Energy Density Physics Experiments with Intense Heavy Ion Beams

The US heavy ion fusion science program has developed techniques for heating ion-beam-driven warm dense matter (WDM) targets. The WDM conditions are to be achieved by combined longitudinal and transverse space-charge neutralized drift compression of the ion beam to provide a hot spot on the target with a beam spot size of about 1 mm, and pulse length about 1-2 ns. As a technique for heating volumetric samples of matter to high energy density, intense beams of heavy ions are capable of delivering precise and uniform beam energy deposition dE/dx, in a relatively large sample size, and the ability to heat any solid-phase target material. Initial experiments use a 0.3 MeV K+ beam (below the Bragg peak) from the NDCX-I accelerator. Future plans include target experiments using the NDCX-II accelerator, which is designed to heat targets at the Bragg peak using a 3-6 MeV lithium ion beam. The range of the beams in solid matter targets is about 1 micron, which can be lengthened by using porous targets at reduced density. We have completed the fabrication of a new experimental target chamber facility for WDM experiments, and implemented initial target diagnostics to be used for the first target experiments in NDCX-1. The target chamber has been installed on the NDCX-I beamline. The target diagnostics include a fast multi-channel optical pyrometer, optical streak camera, VISAR, and high-speed gated cameras. Initial WDM experiments will heat targets by compressed NDCX-I beams and will explore measurement of temperature and other target parameters. Experiments are planned in areas such as dense electronegative targets, porous target homogenization and two-phase equation of state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear Excitation and Fission Studies with Short Pulsed Laser-Driven High Energy Gamma Rays

We propose the development of a platform to study photon excitation of high Z nuclei utilizing a high energy (70 J) short pulsed (500 fs) laser to drive > 5 MeV γ-radiation. The laser beam will be focused onto a specially prepared foam or corrugated conveying target, where it generates relativistic MeV electrons via ponderomotive and wake-field acceleration mechanisms. γ-emission is produced in the form of bremsstrahlung in the same target or in a separated high-Z γ-production target hit by the accelerated MeV electrons. The high energy γ-rays will be utilized to provide nuclear state excitation in the short time domain. The γ platform will allow to investigate photo fission of high Z target material positioned in an auxiliary target chamber in the γ-ray beam path via the established gas transport scheme. The photo fission yield will provide furthermore diagnostic information on the produced γ-yield. In addition, γ-spectroscopy will be used to identify γ-lines for the diagnostic of the excited state population of high Z target nuclei. This research capability is relevant to the understanding of how nuclear excitation effects fission, in relevance to recent astrophysical observations on element nucleosynthesis. These processes involve neutron-rich fragments and processes such as fission recycling (e. g. in neutron stars outer crusts).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative assessment of prognosis of the stop stimulus and trapezoidal rotation programs

For prognosis of the diagnostic possibilities of the stop stimulus and trapezoidal rotation programs with respect to the nystagmus response, 24 healthy young persons with normal auditory and vestibular analysers were studied experimentally. The trapezoidal program more accurately reflects the function and tone balance of the vestibular system than the stop stimulus program and causes the subject no unpleasant sensations during the study. Some optimum couples, acceleration and armchair rotation rate, necessary for effective deviation of the cupuloendolymphatic system were determined. The maximum angular velocity of the slow nystagmus component was more informative than nystagmus duration. The trapezoidal program is recommended for otoneurological practice and the maximum angular velocity of the slow nystagmus component as the basic index.

Grigorova, V. K.↗

Light Microscopy Module Fan Disturbance Characterized Through Microgravity Emissions Laboratory Testing

A Light Microscopy Module (LMM) is being engineered, designed, and developed at the NASA Glenn Research Center. The LMM is planned as a remotely controllable on-orbit microscope subrack facility, allowing flexible scheduling and control of physical science and biological science experiments within Glenn s Fluids Integrated Rack on the International Space Station. The LMM concept is a modified commercial research imaging light microscope with powerful laser-diagnostic hardware and interfaces, creating a one-of-a-kind, state-of-the-art microscopic research facility. The microscope will house several different objectives, corresponding to magnifications of 10, 40, 50, 63, and 100. Features of the LMM include high-resolution color video microscopy, brightfield, darkfield, phase contrast, differential interference contrast, spectrophotometry, and confocal microscopy combined in a single configuration. Also, laser tweezers are integrated with the diagnostics as a sample manipulation technique. As part of the development phase of the LMM, it was necessary to quantify the microgravity disturbances generated by the control box fan. Isolating the fan was deemed necessary to reduce the fan speed harmonic amplitudes and to eliminate any broadband disturbances across the 60- to 70-Hz and 160- to 170-Hz frequency ranges. The accelerations generated by a control box fan component of the LMM were measured in the Microgravity Emissions Laboratory (MEL). The MEL is a low-frequency measurement system developed to simulate and verify the on-orbit International Space Station (ISS) microgravity environment. The accelerations generated by various operating components of the ISS, if too large, could hinder the science performed onboard by disturbing the microgravity environment. The MEL facility gives customers a test-verified way of measuring their compliance with ISS limitations on vibratory disturbance levels. The facility is unique in that inertial forces in 6 degrees of freedom can be characterized simultaneously for an operating test article. Vibratory disturbance levels are measured for engineering or flight-level hardware following development from component to subassembly through the rack-level configuration. The MEL can measure accelerations as small as 10-7g, the accuracy needed to confirm compliance with ISS requirements.

McNelis, Anne M.↗

The Two-Phase Flow Separator Experiment Breadboard Model: Reduced Gravity Aircraft Results

Life support systems in space depend on the ability to effectively separate gas from liquid. Passive cyclonic phase separators use the centripetal acceleration of a rotating gas-liquid mixture to carry out phase separation. The gas migrates to the center, while gas-free liquid may be withdrawn from one of the end plates. We have designed, constructed and tested a breadboard that accommodates the test sections of two independent principal investigators and satisfies their respective requirements, including flow rates, pressure and video diagnostics. The breadboard was flown in the NASA low-gravity airplane in order to test the system performance and design under reduced gravity conditions.

phase separation↗

HIGH ENERGY DENSITY PHYSICS EXPERIMENTS WITH INTENSE HEAVY ION BEAMS

The US heavy ion fusion science program has developed techniques for heating ion-beam-driven warm dense matter (WDM) targets. The WDM conditions are to be achieved by combined longitudinal and transverse space-charge neutralized drift compression of the ion beam to provide a hot spot on the target with a beam spot size of about 1 mm, and pulse length about 1-2 ns. As a technique for heating volumetric samples of matter to high energy density, intense beams of heavy ions are capable of delivering precise and uniform beam energy deposition dE/dx, in a relatively large sample size, and the ability to heat any solid-phase target material. Initial experiments use a 0.3 MeV K+ beam (below the Bragg peak) from the NDCX-I accelerator. Future plans include target experiments using the NDCX-II accelerator, which is designed to heat targets at the Bragg peak using a 3-6 MeV lithium ion beam. The range of the beams in solid matter targets is about 1 micron, which can be lengthened by using porous targets at reduced density. We have completed the fabrication of a new experimental target chamber facility for WDM experiments, and implemented initial target diagnostics to be used for the first target experiments in NDCX-1. The target chamber has been installed on the NDCX-I beamline. The target diagnostics include a fast multi-channel optical pyrometer, optical streak camera, VISAR, and high-speed gated cameras. Initial WDM experiments will heat targets by compressed NDCX-I beams and will explore measurement of temperature and other target parameters. Experiments are planned in areas such as dense electronegative targets, porous target homogenization and two-phase equation of state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CSR Fields: Direct Numerical Solution of the Maxwell___s Equation

We discuss the properties of the coherent electromagnetic fields of a very short, ultra-relativistic bunch in a rectangular vacuum chamber inside a bending magnet. The analysis is based on the results of a direct numerical solution of Maxwell's equations together with Newton's equations. We use a new dispersion-free time-domain algorithm which employs a more efficient use of finite element mesh techniques and hence produces self-consistent and stable solutions for very short bunches. We investigate the fine structure of the CSR fields including coherent edge radiation. This approach should be useful in the study of existing and future concepts of particle accelerators and ultrafast coherent light sources. The coherent synchrotron radiation (CSR) fields have a strong action on the beam dynamics of very short bunches, which are moving in the bends of all kinds of magnetic elements. They are responsible for additional energy loss and energy spread; micro bunching and beam emittance growth. These fields may bound the efficiency of damping rings, electron-positron colliders and ultrafast coherent light sources, where high peak currents and very short bunches are envisioned. This is relevant to most high-brightness beam applications. On the other hand these fields together with transition radiation fields can be used for beam diagnostics or even as a powerful resource of THz radiation. A history of the study of CSR and a good collection of references can be found in [1]. Electromagnetic theory suggests several methods on how to calculate CSR fields. The most popular method is to use Lienard-Wiechert potentials. Other approach is to solve numerically the approximate equations, which are a Schrodinger type equation. These numerical methods are described in [2]. We suggest that a direct solution of Maxwell's equations together with Newton's equations can describe the detailed structure of the CSR fields [3].

43 PARTICLE ACCELERATORS↗

Experimental high gradient testing of a 17.1 GHz photonic band-gap accelerator structure

We report the design, fabrication and high gradient testing of a 17.1 GHz Photonic Band Gap accelerator structure. Photonic band-gap (PBG) structures are promising candidates for electron accelerators capable of high-gradient operation because they have the inherent damping of high order modes required to avoid beam breakup instabilities. The 17.1 GHz PBG structure tested was a single cell structure composed of a triangular array of round copper rods of radius 1.45 mm spaced by 8.05 mm. The test assembly consisted of the test PBG cell located between conventional (pillbox) input and output cells, with input power of up to 4 MW from a klystron supplied via a TM01 mode launcher. Breakdown at high gradient was observed by diagnostics including reflected power, downstream and upstream current monitors and visible light emission. The testing procedure was first benchmarked with a conventional disc-loaded waveguide structure, which reached a gradient of 87 MV/m at a breakdown probability of 1.19 × 10^-1 per pulse per meter. The PBG structure was tested with 100 ns pulses at power levels of less than 90 MV/m in order to limit the surface temperature rise to 120 K. The PBG structure reached up to 89 MV/m at a breakdown probability of 1.09×10^-1 per pulse per meter. These test results show that a PBG structure can simultaneously operate at high gradients and low breakdown probability, while also providing wakefield damping.

43 PARTICLE ACCELERATORS↗

Improvement in Interobserver Accuracy in Delineation of the Lumpectomy Cavity Using Fiducial Markers

Purpose: To determine, whether the presence of gold fiducial markers would improve the inter- and intraphysician accuracy in the delineation of the surgical cavity compared with a matched group of patients who did not receive gold fiducial markers in the setting of accelerated partial-breast irradiation (APBI). Methods and Materials: Planning CT images of 22 lumpectomy cavities were reviewed in a cohort of 22 patients; 11 patients received four to six gold fiducial markers placed at the time of surgery. Three physicians categorized the seroma cavity according to cavity visualization score criteria and delineated each of the 22 seroma cavities and the clinical target volume. Distance between centers of mass, percentage overlap, and average surface distance for all patients were assessed. Results: The mean seroma volume was 36.9 cm{sup 3} and 34.2 cm{sup 3} for fiducial patients and non-fiducial patients, respectively (p = ns). Fiducial markers improved the mean cavity visualization score, to 3.6 {+-} 1.0 from 2.5 {+-} 1.3 (p < 0.05). The mean distance between centers of mass, average surface distance, and percentage overlap for the seroma and clinical target volume were significantly improved in the fiducial marker patients as compared with the non-fiducial marker patients (p < 0.001). Conclusions: The placement of gold fiducial markers placed at the time of lumpectomy improves interphysician identification and delineation of the seroma cavity and clinical target volume. This has implications in radiotherapy treatment planning for accelerated partial-breast irradiation and for boost after whole-breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Recurrence in Electively Irradiated Lymph Node Regions After Definitive Accelerated Intensity Modulated Radiation Therapy for Head and Neck Squamous Cell Carcinoma

Purpose: To provide a comprehensive risk assessment on the patterns of recurrence in electively irradiated lymph node regions after definitive radiation therapy for head and neck cancer. Methods and Materials: Two hundred sixty-four patients with stage cT2-4N0-2M0 squamous cell carcinoma of the oropharynx, larynx, or hypopharynx treated with accelerated intensity modulated radiation therapy between 2008 and 2012 were included. On the radiation therapy planning computed tomography (CT) scans from all patients, 1166 lymph nodes (short-axis diameter ≥5 mm) localized in the elective volume were identified and delineated. The exact sites of regional recurrences were reconstructed and projected on the initial radiation therapy planning CT scan by performing coregistration with diagnostic imaging of the recurrence. Results: The actuarial rate of recurrence in electively irradiated lymph node regions at 2 years was 5.1% (95% confidence interval 2.4%-7.8%). Volumetric analysis showed an increased risk of recurrence with increasing nodal volume. Receiver operating characteristic analysis demonstrated that the summed long- and short-axis diameter is a good alternative for laborious volume calculations, using ≥17 mm as cut-off (hazard ratio 17.8; 95% confidence interval 5.7-55.1; P<.001). Conclusions: An important risk factor was identified that can help clinicians in the pretreatment risk assessment of borderline-sized lymph nodes. Not overtly pathologic nodes with a summed diameter ≥17 mm may require a higher than elective radiation therapy dose. For low-risk elective regions (all nodes <17 mm), the safety of dose de-escalation below the traditional 45 to 50 Gy should be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗