Multi-Angle Snowflake Camera Value-Added Product

The Multi-Angle Snowflake Camera (MASC) addresses a need for high-resolution multi-angle imaging of hydrometeors in freefall with simultaneous measurement of fallspeed. As illustrated in Figure 1, the MASC consists of three cameras, separated by 36°, each pointing at an identical focal point approximately 10 cm away. Located immediately above each camera, a light aims directly at the center of depth of field for its corresponding camera. The focal point at which the cameras are aimed lies within a ring through which hydrometeors fall. The ring houses a system of near-infrared emitter-detector pairs, arranged in two arrays separated vertically by 32 mm. When hydrometeors pass through the lower array, they simultaneously trigger all cameras and lights. Fallspeed is calculated from the time it takes to traverse the distance between the upper and lower triggering arrays. The trigger electronics filter out ambient light fluctuations associated with varying sunlight and shadows. The microprocessor onboard the MASC controls the camera system and communicates with the personal computer (PC). The image data is sent via FireWire 800 line, and fallspeed (and camera control) is sent via a Universal Serial Bus (USB) line that relies on RS232-over-USB serial conversion. See Table 1 for specific details on the MASC located at the Oliktok Point Mobile Facility on the North Slope of Alaska. The value-added product (VAP) detailed in this documentation analyzes the raw data (Section 2.0) using Python: images rely on OpenCV image processing library and derived aggregated statistics rely on some clever averaging. See Sections 4.1 and 4.2 for more details on what variables are computed.

47 OTHER INSTRUMENTATION↗

High Energy Physics Network Requirements Review (Final Report, July-October 2020)

Throughout 2020, ESnet and the Office of High Energy Physics (HEP) of the DOE SC organized an ESnet requirements review of HEP-supported activities. Preparation for this event included identification of key stakeholders: program and facility management, research groups, technology providers, and a number of external observers. These individuals were asked to prepare formal case study documents about their relationship to the HEP program to build a complete understanding of the current, near-term, and long-term status, expectations, and processes that will support the science going forward. A series of pre-planning meetings better prepared case study authors for this task, along with guidance on how the review would proceed in a virtual fashion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ARRIVAL TIME DIFFERENCES BETWEEN GRAVITATIONAL WAVES AND ELECTROMAGNETIC SIGNALS DUE TO GRAVITATIONAL LENSING

In this study we demonstrate that general relativity predicts arrival time differences between gravitational wave (GW) and electromagnetic (EM) signals caused by the wave effects in gravitational lensing. The GW signals can arrive earlier than the EM signals in some cases if the GW/EM signals have passed through a lens, even if both signals were emitted simultaneously by a source. GW wavelengths are much larger than EM wavelengths; therefore, the propagation of the GWs does not follow the laws of geometrical optics, including the Shapiro time delay, if the lens mass is less than approximately 10{sup 5} M {sub ⊙}( f /Hz){sup −1}, where f is the GW frequency. The arrival time difference can reach ∼0.1 s ( f /Hz){sup −1} if the signals have passed by a lens of mass ∼8000 M {sub ⊙}( f /Hz){sup −1} with the impact parameter smaller than the Einstein radius; therefore, it is more prominent for lower GW frequencies. For example, when a distant supermassive black hole binary (SMBHB) in a galactic center is lensed by an intervening galaxy, the time lag becomes of the order of 10 days. Future pulsar timing arrays including the Square Kilometre Array and X-ray detectors may detect several time lags by measuring the orbital phase differences between the GW/EM signals in the SMBHBs. Gravitational lensing imprints a characteristic modulation on a chirp waveform; therefore, we can deduce whether a measured arrival time lag arises from intrinsic source properties or gravitational lensing. Determination of arrival time differences would be extremely useful in multimessenger observations and tests of general relativity.

79 ASTRONOMY AND ASTROPHYSICS↗

Scaler Rates from the Pierre Auger Observatory: A New Proxy of Solar Activity

The modulation of low-energy galactic cosmic rays reflects interplanetary magnetic field variations and can provide useful information on solar activity. An array of ground-surface detectors can reveal the secondary particles, which originate from the interaction of cosmic rays with the atmosphere. In this work, we present an investigation of the low-threshold rate (scaler) time series recorded in 16 yr of operation by the Pierre Auger Observatory surface detectors in Malargüe, Argentina. Through an advanced spectral analysis, we detected highly statistically significant variations in the time series with periods ranging from the decadal to the daily scale. We investigate their origin, revealing a direct connection with solar variability. Thanks to their intrinsic very low noise level, the Auger scalers allow a thorough and detailed investigation of the galactic cosmic-ray flux variations in the heliosphere at different timescales and can, therefore, be considered a new proxy of solar variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of an MLE Algorithm for Quantification of Aerial Radiological Measurements

Aerial radiation detection is routinely used by many organizations (DHS, DOE, EPA, etc.) for the purposes of identifying the presence of and quantifying the existence of radiation along the ground. This work involves the search for lost or missing sources, as well as the characterization of large-scale releases such as might occur in a nuclear power plant accident. The standard in aerial radiological surveys involves flying large arrays of sodium-iodide detectors at altitude (15 to 700 meters) to acquire geo-referenced, 1 Hz, 1024-channel spectra. The historical shortfalls of this technology include: • Very low spatial resolution (typical field of view is circle of two-times altitude) • Relatively low detectability associated with large stand-off distances • Fundamental challenges in performing ground-level quantification This work uses modern computational power in conjunction with multi-dimensional deconvolution algorithms in an effort to improve spatial resolution, enhance detectability, and provide a robust framework for quantification.

Aerial radiological detection, measurement, survey↗

New Experiments for Detecting Emissions from Fission

Ensuring that nuclear science and technology is used solely for peaceful purposes is one of the most pressing challenges facing our society. The Consortium for Monitoring, Technology, and Verification (MTV) mission is to help meet this challenge by providing advanced technology and trained talent for careers in nuclear security and nonproliferation. The study of nuclear fission is one area of interest in the MTV. We are performing new experiments for the characterization of neutron and gamma ray emissions from fission fragments. These emissions are signatures for the detection and characterization of nuclear materials. To perform these experiments, we have developed Fission Sphere (FS-3), an array of forty organic stilbene detectors operated in time-coincidence. The FS-3 is used to measure the prompt emissions of neutrons and gamma rays from Cf-252 spontaneous fission. These new data will be used to validate physics-based prediction codes, including CGMF and FREYA, and will be useful in future ENDF and ENSDF evaluations. This paper will present results from the first experiments using FS-3 and a Cf-252 spontaneous fission source. It will compare the experimental results with predictions from theory and Monte Carlo simulation. Specifically, we will describe the correlations among energy, multiplicity, and angles of emitted particles. We will also discuss the application of these correlations in multiplicity counting techniques, which are widely used in nuclear safeguards.

Pozzi, S. A.↗

Estimating β eff from static, late-time Feynman neutron noise measurements

The effective delayed neutron fraction, β eff , is a kinematic parameter describing the contribution of delayed neutrons to the effective multiplication factor, $\kappa$ eff , and is of great interest to the nuclear criticality safety community and beyond. In fact, $\kappa$ eff presently must be inferred (as opposed to directly measured) since variables like β eff must be obtained from simulation, reference tables, or a dynamic or pulsed measurement where the assembly of fissile material is perturbed and not in steady state. Several recent works have proposed neutron noise techniques to estimate β eff from static measurements (such as benchmark experiments). This work experimentally investigates an approach based on looking at late-time (up to thousands of seconds) correlated neutrons in Feynman histograms. This work utilizes measurements of weapons grade plutonium and highly enriched uranium to construct late-time Feynman histograms and investigate a proposed methodology of estimating β eff from a fit of the distribution. Data is shown from both He-3 detectors and an organic scintillator array. This work is preliminary in nature, demonstrating some experimental feasibility and proposing improvements for future investigations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

Idaho Explosives Detection System: Development and Enhancements

The Idaho Explosives Detection System (IEDS) was developed at the Idaho National Laboratory (INL) to respond to threats imposed by delivery trucks carrying bulk explosives into military bases. The system consists of two racks, one on each side of a subject vehicle. Each rack includes a neutron generator and an array of sodium iodide (NaI) detectors. The two neutron generators are pulsed and synchronized. A computer connects to the system by Ethernet and is able to control the system remotely. The system was developed to detect bulk explosives in a medium size truck within a 5-minute measurement time. In 2004, a full-scale prototype IEDS system was built for testing and continued development. System performance was successfully tested using different types of real explosives with a variety of cargo at the INL from November 2005 through February 2006. Recently, the first deployable prototype system was constructed and shipped to Wright-Patterson Air Force Base in Ohio and will be in operation by March 2007. The capability of passively detecting radiological material within a delivery truck has also been added.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Induced-Fission Imaging of Nuclear Material

This paper presents initial results from development of the induced-fission imaging technique, which can be used for the purpose of measuring or verifying the distribution of fissionable material in an unopened container. The technique is based on stimulating fissions in nuclear material with 14 MeV neutrons from an associated-particle deuterium-tritium (D-T) generator and counting the subsequent induced fast fission neutrons with an array of fast organic scintillation detectors. For each source neutron incident on the container, the neutron creation time and initial trajectory are known from detection of the associated alpha particle of the d + t → α + n reaction. Many induced fissions will lie along (or near) the interrogating neutron path, allowing an image of the spatial distribution of prompt induced fissions, and thereby fissionable material, to be constructed. A variety of induced-fission imaging measurements have been performed at Oak Ridge National Laboratory with a portable, low-dose D-T generator, including single-view radiographic measurements and three-dimensional tomographic measurements. Results from these measurements will be presented along with the neutron transmission images that have been performed simultaneously. This new capability may have applications to a number of areas in which there may be a need to confirm the presence or configuration of nuclear materials, such as nuclear material control and accountability, quality assurance, treaty confirmation, or homeland security applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Multi-chroic MKIDs for Next-Generation CMB Polarization Studies

We report on the status of an ongoing effort to develop arrays of horn-coupled, polarization-sensitive microwave kinetic inductance detectors (MKIDs) that are each sensitive to two spectral bands between 125 and 280 GHz. These multi-chroic MKID arrays are tailored for next-generation, large-detector-count experiments that are being designed to simultaneously characterize the polarization properties of both the cosmic microwave background and Galactic dust emission. We present our device design and describe laboratory-based measurement results from two 23-element prototype arrays. From dark measurements of our first engineering array, we demonstrated a multiplexing factor of 92, showed the resonators respond to bath temperature changes as expected, and found that the fabrication yield was 100%. From our first optically loaded array, we found the MKIDs respond to millimeter-wave pulses; additional optical characterization measurements are ongoing. We end by discussing our plans for scaling up this technology to kilo-pixel arrays over the next 2 years.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-resolution neutron crystallographic studies of the hydration of the coenzyme cob(II)alamin

High-resolution crystallographic studies of the hydration of the coenzyme cob(II)alamin have provided hydrogen-bond parameters of unprecedented accuracy for a biomacromolecule. The hydration of the coenzyme cob(II)alamin has been studied using high-resolution monochromatic neutron crystallographic data collected at room temperature to a resolution of 0.92 Å on the original D19 diffractometer with a prototype 4° × 64° detector at the high-flux reactor neutron source run by the Institute Laue–Langevin. The resulting structure provides hydrogen-bonding parameters for the hydration of biomacromolecules to unprecedented accuracy. These experimental parameters will be used to define more accurate force fields for biomacromolecular structure refinement. The presence of a hydrophobic bowl motif surrounded by flexible side chains with terminal functional groups may be significant for the efficient scavenging of ligands. The feasibility of extending the resolution of this structure to ultrahigh resolution was investigated by collecting time-of-flight neutron crystallographic data during commissioning of the TOPAZ diffractometer with a prototype array of 14 modular 2° × 21° detectors at the Spallation Neutron Source run by Oak Ridge National Laboratory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A compact digital time differential perturbed angular correlation-spectrometer using field programmable gate arrays and various timestamp algorithms

A user-friendly fully digital time differential perturbed angular correlation (TDPAC)-spectrometer with six detectors and fast digitizers using field programmable gate arrays (FPGA) is described and performance data are given. The new spectrometer has an online data analysis feature, a compact size, and a time resolution such as conventional analog spectrometers. Its calculation intensive part was implemented inside the digitizer. This gives the possibility to change parameters (energy windows, constant fraction trigger delay) and see their influence immediately in the {gamma}-{gamma} correlation diagrams. Tests were performed which showed that the time resolution using a {sup 60}Co source with energy window set at 1.17 MeV and 1.33 MeV is 265 ps with LaBr{sub 3}(Ce) scintillators and 254 ps with BaF{sub 2} scintillators. A true constant fraction algorithm turned out to be slightly better than the constant fraction of amplitude method. The spectrometer performance was tested with a TDPAC measurement using a {sup 44}Ti in rutile source and a positron lifetime measurement using {sup 22}Na. The maximum possible data rate of the spectrometer is 1.1 x 10{sup 6} {gamma} quanta per detector and second.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Thick CZT Detectors for X-ray and Gamma-ray Astronomy

CdZnTe (CZT) is a wide bandgap II-VI semiconductor developed for the spectroscopic detection of X-rays and {gamma}-rays at room temperature. The Swift Burst Alert Telescope is using an 5240 cm{sup 2} array of 2 mm thick CZT detectors for the detection of 15-150 keV X-rays from Gamma-ray Bursts. We report on the systematic tests of thicker (0.5 cm) CZT detectors with volumes between 2 cm{sup 3} and 4 cm{sup 3} which are potential detector choices for a number of future X-ray telescopes that operate in the 10 keV to a few MeV energy range. The detectors contacted in our laboratory achieve Full Width Half Maximum energy resolutions of 2.7 keV (4.5%) at 59 keV, 3 keV (2.5%) at 122 keV and 4 keV (0.6%) at 662 keV. The 59 keV and 122 keV energy resolutions are among the world-best results for 0.5 cm thick CZT detectors. We use the data set to study trends of how the energy resolution depends on the detector thickness and on the pixel pitch. Unfortunately, we do not find clear trends, indicating that even for the extremely good energy resolutions reported here, the achievable energy resolutions are largely determined by the properties of individual crystals. Somewhat surprisingly, we achieve the reported results without applying a correction of the anode signals for the depth of the interaction. Measuring the interaction depths thus does not seem to be a pre-requisite for achieving sub-1% energy resolutions at 662 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy X-ray pinhole imaging at the Z facility

A new high photon energy (hν > 15 keV) time-integrated pinhole camera (TIPC) has been developed as a diagnostic instrument at the Z facility. This camera employs five pinholes in a linear array for recording five images at once onto an image plate detector. Each pinhole may be independently filtered to yield five different spectral responses. The pinhole array is fabricated from a 1-cm thick tungsten block and is available with either straight pinholes or conical pinholes. Each pinhole within the array block is 250 μm in diameter. The five pinholes are splayed with respect to each other such that they point to the same location in space, and hence present the same view of the radiation source at the Z facility. The fielding distance from the radiation source is 66 cm and the nominal image magnification is 0.374. Initial experimental results from TIPC are shown to illustrate the performance of the camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The New Position Sensitive Triple Cluster Detector For AGATA

The first triple cluster detector was successfully assembled for the next generation high-resolution gamma-ray spectrometer: the Advanced Gamma Tracking Array AGATA. The core part of the detector consists of three encapsulated, 36-fold segmented, high-purity germanium detectors (HPGe) which are operated in a common cryostat. All 111 energy channels are equipped with cold FETs. They provide best energy resolution of core and segment signals. The observable energy range of the Ge detectors was extended up to 100 MeV by applying a time over threshold technique with the newly developed AGATA preamplifiers. Energy resolution for high energetic {gamma}-rays above 10 MeV is measured to be comparable with values obtained with the standard pulse height technique. Detailed cross-talk investigations were performed in order to improve position dependent pulse shape information. For the Ge detectors and its analog preamplifier circuitry a low cross-talk level was determined which compares well with the expected calculated contributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical and psychophysical characterization of a novel clinical system for digital mammography

Purpose: In recent years, many approaches have been investigated on the development of full-field digital mammography detectors and implemented in practical clinical systems. Some of the most promising techniques are based on flat panel detectors, which, depending on the mechanism involved in the x-ray detection, can be grouped into direct and indirect flat panels. Direct detectors display a better spatial resolution due to the direct conversion of x rays into electron-hole pairs, which do not need an intermediate production of visible light. In these detectors the readout is usually achieved through arrays of thin film transistors (TFTs). However, TFT readout tends to display noise characteristics worse than those from indirect detectors. To address this problem, a novel clinical system for digital mammography has been recently marketed based on direct-conversion detector and optical readout. This unit, named AMULET and manufactured by FUJIFILM, is based on a dual layer of amorphous selenium that acts both as a converter of x rays (first layer) and as an optical switch for the readout of signals (second layer) powered by a line light source. The optical readout is expected to improve the noise characteristics of the detector. The aim is to obtain images with high resolution and low noise, thanks to the combination of optical switching technology and direct conversion with amorphous selenium. In this article, the authors present a characterization of an AMULET system. Methods: The characterization was achieved in terms of physical figures as modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and contrast-detail analysis. The clinical unit was tested by exposing it to two different beams: 28 kV Mo/Mo (namely, RQA-M2) and 28 kV W/Rh (namely, W/Rh). Results: MTF values of the system are slightly worse than those recorded from other direct-conversion flat panels but still within the range of those from indirect flat panels: The MTF values of the AMULET system are about 45% and 15% at 5 and 8 lp/mm, respectively. On the other hand, however, AMULET NNPS results are consistently better than those from direct-conversion flat panels (up to two to three times lower) and flat panels based on scintillation phosphors. DQE results lie around 70% when RQA-M2 beams are used and approaches 80% in the case of W/Rh beams. Contrast-detail analysis, when performed by human observers on the AMULET system, results in values better than those published for other full-field digital mammography systems. Conclusions: The novel clinical unit based on direct-conversion detector and optical reading presents great results in terms of both physical and psychophysical characterizations. The good spatial resolution, combined with excellent noise properties, allows the achievement of very good DQE, better than those published for clinical FFDM systems. The psychophysical analysis confirms the excellent behavior of the AMULET unit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Note: A resonating reflector-based optical system for motion measurement in micro-cantilever arrays

A robust, compact optical measurement unit for motion measurement in micro-cantilever arrays enables development of portable micro-cantilever sensors. This paper reports on an optical beam deflection-based system to measure the deflection of micro-cantilevers in an array that employs a single laser source, a single detector, and a resonating reflector to scan the measurement laser across the array. A strategy is also proposed to extract the deflection of individual cantilevers from the acquired data. The proposed system and measurement strategy are experimentally evaluated and demonstrated to measure motion of multiple cantilevers in an array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗