Search NASA⌕ Search

SEARCH · Search NASA

Results for “cavity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Face seal assembly with thermal management circuit and an associated method thereof

A face seal assembly including a thermal fluid circuit, a turbomachine including the face seal assembly and a method of operating the turbomachine are disclosed. The face seal assembly includes a seal ring including a seal bearing face, at least one internal cavity including a cavity inlet and a cavity outlet. The face seal assembly further including a fluid inlet channel in fluid communication with the cavity inlet of the at least one internal cavity and a pressurized fluid and a fluid outlet port in fluid communication with the cavity outlet of the at least one internal cavity. The at least one internal cavity, the fluid inlet channel and the fluid outlet port define a thermal fluid circuit providing thermal management of the seal ring. In the turbomachine, the face seal assembly is disposed between a stationary component and a rotating component including a rotating component bearing face.

Trivedi, Deepak↗

Cooperative emission from an ensemble of three-level Λ radiators in a cavity: An insight from the viewpoint of dynamics of nonlinear systems

Cooperative radiation emitted by an ensemble of three-level optical systems with a doublet in the ground state (Λ scheme), which is placed into a cyclic cavity, is studied theoretically. In contrast to the two-level model of emitters, this process with such a configuration of operating transitions may occur without population inversion in the whole, if the doublet is prepared at the initial instant in a superposition (coherent) state. In the ideal case of a Hamilton system, in which the cavity losses and relaxation in the radiator ensemble are disregarded, the conservation laws are derived, which allow a substantial reduction of the dimension of the phase space of the model (ℝ{sup 11} → ℝ{sup 5}) and the application of methods of dynamics of nonlinear systems for analyzing the three-level superradiance under these conditions. The possibility of different (both quasiperiodic and chaotic) scenarios of the three-level superradiance is demonstrated on the basis of Poincaré’s mappings. Global bifurcation of the system upon a transition from the conventional superradiance regime to inversionless one is revealed. The effects of cavity losses, as well as homogeneous and inhomogeneous broadening in the system of radiators on the regularities found are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calculations of separated 3-D flows with a pressure-staggered Navier-Stokes equations solver

A Navier-Stokes equations solver based on a pressure correction method with a pressure-staggered mesh and calculations of separated three-dimensional flows are presented. It is shown that the velocity pressure decoupling, which occurs when various pressure correction algorithms are used for pressure-staggered meshes, is caused by the ill-conditioned discrete pressure correction equation. The use of a partial differential equation for the incremental pressure eliminates the velocity pressure decoupling mechanism by itself and yields accurate numerical results. Example flows considered are a three-dimensional lid driven cavity flow and a laminar flow through a 90 degree bend square duct. For the lid driven cavity flow, the present numerical results compare more favorably with the measured data than those obtained using a formally third order accurate quadratic upwind interpolation scheme. For the curved duct flow, the present numerical method yields a grid independent solution with a very small number of grid points. The calculated velocity profiles are in good agreement with the measured data.

Kim, S.-W.↗

Calculations of separated 3-D flows with a pressure-staggered Navier-Stokes equations solver

A Navier-Stokes equations solver based on a pressure correction method with a pressure-staggered mesh and calculations of separated three-dimensional flows are presented. It is shown that the velocity pressure decoupling, which occurs when various pressure correction algorithms are used for pressure-staggered meshes, is caused by the ill-conditioned discrete pressure correction equation. The use of a partial differential equation for the incremental pressure eliminates the velocity pressure decoupling mechanism by itself and yields accurate numerical results. Example flows considered are a three-dimensional lid driven cavity flow and a laminar flow through a 90 degree bend square duct. For the lid driven cavity flow, the present numerical results compare more favorably with the measured data than those obtained using a formally third order accurate quadratic upwind interpolation scheme. For the curved duct flow, the present numerical method yields a grid independent solution with a very small number of grid points. The calculated velocity profiles are in good agreement with the measured data.

Kim, S.-W.↗

Chromaticity of the lattice and beam stability in energy-recovery linacs

Energy recovery linacs (ERLs) are an emerging generation of accelerators promising to revolutionize the fields of high-energy physics and photon sciences. These accelerators combine the advantages of linear accelerators with that of storage rings, and hold the promise of delivering electron beams of unprecedented power and quality. Use of superconducting radio-frequency (SRF) cavities converts ERLs into nearly perfect 'perpetuum mobile' accelerators, wherein the beam is accelerated to a desirable energy, used, and then gives the energy back to the RF field. One potential weakness of these devices is transverse beam break-up instability that could severely limit the available beam current. In this paper, I present a method of suppressing these dangerous effects using a natural phenomenon in the accelerators, viz., the chromaticity of the transverse motion.

43 PARTICLE ACCELERATORS↗

Development of in situ thickness sensor for vapor diffused Nb3Sn films

Fermilab is one of the leaders in development of vapor diffused Nb3Sn films inside niobium cavities. This material has a higher critical temperature (Tc) than niobium, enabling cavity operation at 4.2 K. This higher operational temperature significantly reduces the infrastructure required for cooling compared to 2 K systems, making superconducting radio-frequency (SRF) technology more accessible. Current deposition methods have relied on iterative testing to determine nominal film thickness, a process that can be time-consuming and imprecise. To address this, we are developing a sensor to measure the thickness of Nb3Sn thin film in situ during vapor diffusion. Our design involves a four-point resistance measurement of a thin film of niobium, inside the coating region. During coating, the change in resistance reflects the conversion of the film from Nb to Nb3Sn, which allows simple integration with the current furnace infrastructure. This sensor would allow real time measurement of the Nb3Sn film thickness, allowing for increased precision in future depositions for cavity applications.

Howard, K. [Chicago U.] (ORCID:0000000325613308)↗

Minimization of thermal deformation in crystal optics for high repetition-rate FEL

Minimizing thermal deformation in X-ray crystal optics is crucial for preserving coherence and wavefront in high-repetition-rate free-electron lasers (FELs). This study presents two approaches to reduce pulse-by-pulse transient thermal deformation in diamond crystals used in cavity-based X-ray FELs (CBXFELs): (1) cryogenic cooling with liquid nitrogen (LN₂), and (2) second-order correction via focusing optics. We revisit the temperature-dependent thermal-mechanical properties of diamond and silicon, implement a finite-element analysis (FEA) method to accelerate convergence to a quasisteady-state regime. Results show that LN₂-cooled diamond crystals meet the stringent deformation requirement of less than 15 pm RMS for the pulse at mJ scale at 1 MHz repetition frequency, and up to 1.5 mJ for 100 kHz. Second-order correction by using focusing elements within the cavity can reduce the impact of thermal deformation for both liquid nitrogen and water cooling.

free electron laser↗

Large Eddy/Reynolds-Averaged Navier-Stokes Simulations of CUBRC Base Heating Experiments

ven with great advances in computational techniques and computing power during recent decades, the modeling of unsteady separated flows, such as those encountered in the wake of a re-entry vehicle, continues to be one of the most challenging problems in CFD. Of most interest to the aerothermodynamics community is accurately predicting transient heating loads on the base of a blunt body, which would result in reduced uncertainties and safety margins when designing a re-entry vehicle. However, the prediction of heat transfer can vary widely depending on the turbulence model employed. Therefore, selecting a turbulence model which realistically captures as much of the flow physics as possible will result in improved results. Reynolds Averaged Navier Stokes (RANS) models have become increasingly popular due to their good performance with attached flows, and the relatively quick turnaround time to obtain results. However, RANS methods cannot accurately simulate unsteady separated wake flows, and running direct numerical simulation (DNS) on such complex flows is currently too computationally expensive. Large Eddy Simulation (LES) techniques allow for the computation of the large eddies, which contain most of the Reynolds stress, while modeling the smaller (subgrid) eddies. This results in models which are more computationally expensive than RANS methods, but not as prohibitive as DNS. By complimenting an LES approach with a RANS model, a hybrid LES/RANS method resolves the larger turbulent scales away from surfaces with LES, and switches to a RANS model inside boundary layers. As pointed out by Bertin et al., this type of hybrid approach has shown a lot of promise for predicting turbulent flows, but work is needed to verify that these models work well in hypersonic flows. The very limited amounts of flight and experimental data available presents an additional challenge for researchers. Recently, a joint study by NASA and CUBRC has focused on collecting heat transfer data on the backshell of a scaled model of the Orion Multi-Purpose Crew Vehicle (MPCV). Heat augmentation effects due to the presence of cavities and RCS jet firings were also investigated. The high quality data produced by this effort presents a new set of data which can be used to assess the performance of CFD methods. In this work, a hybrid LES/RANS model developed at North Carolina State University (NCSU) is used to simulate several runs from these experiments, and evaluate the performance of high fidelity methods as compared to more typical RANS models. .

Salazar, Giovanni↗

Comparative Analysis of the Post-Lumpectomy Target Volume Versus the Use of Pre-Lumpectomy Tumor Volume for Early-Stage Breast Cancer: Implications for the Future

Purpose: Three-dimensional conformal accelerated partial breast irradiation (APBI-3D-CRT) is commonly associated with the treatment of large amounts of normal breast tissue. We hypothesized that a planning tumor volume (PTV) generation based on an expansion of the pre-lumpectomy (pre-LPC) intact tumor volume would result in smaller volumes of irradiated normal breast tissue compared with using a PTV based on the post-lumpectomy cavity (post-LPC). Use of PTVs based on the pre-LPC might also result in greater patient eligibility for APBI-3D-CRT. Methods and Materials: Forty-one early-stage breast cancers were analyzed. Preoperative imaging was used to determine a pre-LPC tumor volume. PTVs were developed in the pre- and post-LPC settings as per National Surgical Breast and Bowel Project (NSABP)-B39 guidelines. The pre- and post-LPC PTV volumes were compared and eligibility for APBI-3D-CRT determined using NSABP-B39 criteria. Results: The post-LPC PTV exceeded the pre-LPC PTV in all cases. The median volume for the pre- and post-LPC PTVs were 93 cm{sup 3} (range, 24-570 cm{sup 3}) and 250 cm{sup 3} (range, 45-879 cm{sup 3}), respectively, p <0.001. The difference between pre- and post-LPC PTVs represented a median of 165 cc (range, 21-482 cc) or 16% (range, 3%-42%) of the whole breast volume. Three of 41 vs. 13 of 41 cases were ineligible for APBI-3D-CRT when using the pre- and post-LPC PTVs, respectively. Conclusion: PTVs based on pre-LPC tumor expansion are likely associated with reduced amounts of irradiated normal breast tissue compared with post-LPC PTVs, possibly leading to greater patient eligibility for APBI-3D-CRT. These findings support future investigation as to the feasibility of neoadjuvant APBI-3D-CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Objective and Longitudinal Assessment of Dermatitis After Postoperative Accelerated Partial Breast Irradiation Using High-Dose-Rate Interstitial Brachytherapy in Patients With Breast Cancer Treated With Breast Conserving Therapy: Reduction of Moisture Deterioration by APBI

Purpose: To objectively evaluate the radiation dermatitis caused by accelerated partial breast irradiation (APBI) using high-dose-rate interstitial brachytherapy. Patients and Methods: The skin color and moisture changes were examined using a newly installed spectrophotometer and corneometer in 22 patients who had undergone APBI using open cavity implant high-dose-rate interstitial brachytherapy (36 Gy in six fractions) and compared with the corresponding values for 44 patients in an external beam radiotherapy (EBRT) control group (50-60 Gy in 25-30 fractions within 5-6 weeks) after breast conserving surgery. Results: All values changed significantly as a result of APBI. The extent of elevation in a Asterisk-Operator (reddish) and reduction in L Asterisk-Operator (black) values caused by APBI were similar to those for EBRT, with slightly delayed recovery for 6-12 months after treatment owing to the surgical procedure. In contrast, only APBI caused a change in the b Asterisk-Operator values, and EBRT did not, demonstrating that the reduction in b Asterisk-Operator values (yellowish) depends largely on the surgical procedure. The changes in moisture were less severe after APBI than after EBRT, and the recovery was more rapid. The toxicity assessment using the Common Toxicity Criteria, version 3, showed that all dermatitis caused by APBI was Grade 2 or less. Conclusion: An objective analysis can quantify the effects of APBI procedures on color and moisture cosmesis. The radiation dermatitis caused by APBI using the present schedule showed an equivalent effect on skin color and a less severe effect on moisture than the effects caused by standard EBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distant Metastases in Head-and-Neck Squamous Cell Carcinoma Treated With Intensity-Modulated Radiotherapy

Purpose: To determine the pattern and risk factors for distant metastases in head-and-neck squamous cell carcinoma (HNSCC) after curative treatment with intensity-modulated radiotherapy (IMRT). Methods and Materials: This was a retrospective study of 284 HNSCC patients treated in a single institution with IMRT. Sites included were oropharynx (125), oral cavity (70), larynx (55), hypopharynx (17), and unknown primary (17). American Joint Committee on Cancer stage distribution includes I (3), II (19), III (42), and IV (203). There were 224 males and 60 females with a median age of 57. One hundred eighty-six patients were treated with definitive IMRT and 98 postoperative IMRT. One hundred forty-nine patients also received concurrent cisplatin-based chemotherapy. Results: The median follow-up for all patients was 22.8 months (range, 0.07-77.3 months) and 29.5 months (4.23-77.3 months) for living patients. The 3-year local recurrence-free survival, regional recurrence-free survival, locoregional recurrence-free survival, distant metastasis-free survival, and overall survival were 94.6%, 96.4%, 92.5%, 84.1%, and 68.95%, respectively. There were 45 patients with distant metastasis. In multivariate analysis, distant metastasis was strongly associated with N stage (p = 0.046), T stage (p < 0.0001), and pretreatment maximum standardized uptake value of the lymph node (p = 0.006), but not associated with age, gender, disease sites, pretreatment standardized uptake value of the primary tumor, or locoregional control. The freedom from distant metastasis at 3 years was 98.1% for no factors, 88.6% for one factor, 68.3% for two factors, and 41.7% for three factors (p < 0.0001 by log-rank test). Conclusion: With advanced radiation techniques and concurrent chemotherapy, the failure pattern has changed with more patients failing distantly. The majority of patients with distant metastases had no local or regional failures, indicating that these patients might have microscopic distant disease before treatment. The clinical factors identified here should be incorporated in future clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Niobium uptake by a [P 8 W 48 O 184 ] 40− macrocyclic polyanion

Incorporation of Nb into the [P 8 W 48 O 184 ] 40− anionic macrocyclic cavitand leads to formation of new Nb–W POMs. Inclusion of up to five {NbO(H 2 O)} 3+ groups was observed. Solution speciation of the Nb-encapsulating macrocycles was studied by HPLC-ICP-AES and SAXS.

Shmakova, Alexandra A.↗

Designing and optimizing highly efficient grating for high-brightness laser based on spectral beam combining

A highly efficient nano-periodical grating is theoretically investigated for spectral beam combining (SBC) and is experimentally implemented for attaining high-brightness laser from a diode laser array. The rigorous coupled-wave analysis with the S matrix method is employed to optimize the parameters of the grating. According the optimized parameters, the grating is fabricated and plays a key role in SBC cavity. The diffraction efficiency of this grating is optimized to 95% for the output laser which is emitted from the diode laser array. The beam parameter product of 3.8 mm mrad of the diode laser array after SBC is achieved at the output power of 46.3 W. The optical-to-optical efficiency of SBC cavity is measured to be 93.5% at the maximum operating current in the experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Path-integral Monte Carlo study of particles obeying quantum mechanics and classical statistics

Ultracold atomic systems have been of great research interest in the past, with more recent attention being paid to systems of mixed species. In this work, we carry out nonperturbative path-integral Monte Carlo (PIMC) simulations of $N$ distinguishable particles at finite temperature, which can be thought of as an ultracold atomic system containing $N$ distinct species. We use the PIMC approach to calculate thermodynamic properties of particles interacting via hard-sphere and hard-cavity potentials. The first problem we study is a two-particle system interacting via a hard-sphere and hard-cavity interaction in order to test the effectiveness of two approximations for the thermal density matrix corresponding to these potentials. We then apply the PIMC method to a system of many hard-sphere particles under periodic boundary conditions at varying temperature in order to calculate the energy per particle, pressure, and specific heat of the system. We examine how finite-size effects impact the results of PIMC simulations of hard-sphere particles and when the thermodynamic limit has been reached. Finally, our results provide microscopic benchmarks for a system containing distinguishable particles, which can be thought of as a limiting case for ultracold atomic systems of mixed species.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conceptual design of a high reactive-power ferroelectric fast reactive tuner

We present a novel design of a ferroelectric fast reactive tuner (FE-FRT) capable of modulating mega-VAR reactive power on a submicrosecond timescale. The high reactive power capability of our design extends the range of applications of reactive tuners to numerous applications. We present a detailed analytical model of the performance of a megawatt-class reactive power device and benchmark it against finite-element method eigenmode and frequency domain electromagnetic simulations. We introduce new features, including an annulus design for the ferroelectric capacitors and capacitive window coupling to the cavity. We consider thermal design issues and nonlinear effects in the ferroelectric. The model covers several configurations, allowing control of the frequency of superconducting and normal-conducting cavities in a variety of applications and frequencies. We calculate that the FE-FRT designed should be capable of handling around 0.45 MVAR of reactive power with around 3 kW of resistive losses, providing a frequency tuning range of 8 kHz in an example of 400 MHz cavity geometry. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

SU-F-BRE-12: Optical Resonator Water Calorimeter

Purpose: Water calorimetry based on resistance thermometry has matured as a primary standard. Developing an optical technique hold the promise to push the boundaries of what is currently achievable with dosimetry. We will present a feasibility study and the current progress of construction of a Fabry-Perot resonator for dose to water measurement. Additionally, estimations of the theoretical limits resonator sensitivity and potential sources of noise for the system are described. Methods: A temperature change from the dose to water would be measured by the change in the index of refraction from the water in the cavity. Calculations are presented of the expected signal from the resonator for dose to water. The Fabry-Perot resonator constructed from optical quality narrowband mirrors is described. A water cell will be inserted into the cavity gap to provide the medium swept cavity length technique is explored as a specific implementation of this technique. Results: Calculations indicate that a dose to water on the order of a Gray is measureable with a reasonably implementable system. A resonator is currently under construction and progress towards a proof of principle measurement will be presented. The primary sources of noise, in order of importance, are expected to be; optical absorption by the medium, mechanical perturbations of the cavity length and thermal expansion of the optical mounts. Estimations of these noise sources and mitigation techniques will be discussed. Conclusion: A Fabry-Perot resonator is a promising technique for measuring the absorbed dose to water from a radiotherapy beam. This technique has the potential to serve as a check on the current primary standard for dose to water measurements. As well, i0074 may be the foundation for a new class of optical property based dosimetry measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Thermal Performance Evaluation of Walls with Gas Filled Panel Insulation

Gas filled insulation panels (GFP) are very light weight and compact (when uninflated) advanced insulation products. GFPs consist of multiple layers of thin, low emittance (low-e) metalized aluminum. When expanded, the internal, low-e aluminum layers form a honeycomb structure. These baffled polymer chambers are enveloped by a sealed barrier and filled with either air or a low-conductivity gas. The sealed exterior aluminum foil barrier films provide thermal resistance, flammability protection, and properties to contain air or a low conductivity inert gas. This product was initially developed with a grant from the U.S. Department of Energy. The unexpanded product is nearly flat for easy storage and transport. Therefore, transportation volume and weight of the GFP to fill unit volume of wall cavity is much smaller compared to that of other conventional insulation products. This feature makes this product appealing to use at Army Contingency Basing, when transportation cost is significant compared to the cost of materials. The objective of this study is to evaluate thermal performance of walls, similar to those used at typical Barracks Hut (B-Hut) hard shelters, when GFPs are used in the wall cavities. Oak Ridge National Laboratory (ORNL) tested performance of the wall in the rotatable guarded hotbox (RGHB) according to the ASTM C 1363 standard test method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maximizing 1D “like” implosion performance for inertial confinement fusion science

While the march towards achieving indirectly driven inertial confinement fusion at the NIF has made great progress, the experiments show that multi-dimensional effects still dominate the implosion performance. Low mode implosion symmetry and hydrodynamic instabilities seed by capsule mounting features appear to be two key limiting factors for implosion performance. One reason these factors have a large impact on the performance of ICF implosions is the high convergence required to achieve high fusion gains. To tackle these problems, a predictable implosion platform is needed meaning experiments must trade-off high gain for performance. To this end, LANL has adopted three main approaches to develop a 1D implosion platform where 1D means high yield over 1D clean calculations. Taking advantage of the properties of beryllium capsules, a high adiabat, low convergence platform is being developed. The higher drive efficiency for beryllium enables larger case-to-capsule ratios to improve symmetry at the expense of drive. Smaller capsules with a high adiabat drive are expected to reduce the convergence and thus increase predictability. The second approach is liquid fuel layers using wetted foam targets. With liquid fuel layers, the initial mass in the hot spot can be controlled via the target fielding temperature which changes the liquid vapor pressure. Varying the initial hot spot mass via the vapor pressure controls the implosion convergence and minimizes the need to vaporize the dense fuel layer during the implosion to achieve ignition relevant hot spot densities. The last method is double shell targets. Unlike hot spot ignition, double shells ignite volumetrically. The inner shell houses the DT fuel and the convergence of this cavity is relatively small compared to hot spot ignition. Radiation trapping and the longer confinement times relax the conditions required to ignite the fuel. Key challenges for double shell targets are coupling the momentum of the outer shell to the inner shell and mixing of the mid-Z material from the inner shell into the fuel. The primary theme for each of these approaches is reduced implosion convergence with the goal of achieving a 1D “like” implosion. Once established, a systematic approach to solving limiting issues for ICF can be undertaken. This presentation will discuss the approaches, results, and plans for each of these campaigns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗