Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

An Experimental Study of Upward Burning Over Long Solid Fuels: Facility Development and Comparison

As NASA's mission evolves, new spacecraft and habitat environments necessitate expanded study of materials flammability. Most of the upward burning tests to date, including the NASA standard material screening method NASA-STD-6001, have been conducted in small chambers where the flame often terminates before a steady state flame is established. In real environments, the same limitations may not be present. The use of long fuel samples would allow the flames to proceed in an unhindered manner. In order to explore sample size and chamber size effects, two large chambers were developed at NASA GRC under the Flame Prevention, Detection and Suppression (FPDS) project. The first was an existing vacuum facility, VF-13, located at NASA John Glenn Research Center. This 6350 liter chamber could accommodate fuels sample lengths up to 2 m. However, operational costs and restricted accessibility limited the test program, so a second laboratory scale facility was developed in parallel. By stacking additional two chambers on top of an existing combustion chamber facility, this 81 liter Stacked-chamber facility could accommodate a 1.5 m sample length. The larger volume, more ideal environment of VF-13 was used to obtain baseline data for comparison with the stacked chamber facility. In this way, the stacked chamber facility was intended for long term testing, with VF-13 as the proving ground. Four different solid fuels (adding machine paper, poster paper, PMMA plates, and Nomex fabric) were tested with fuel sample lengths up to 2 m. For thin samples (papers) with widths up to 5 cm, the flame reached a steady state length, which demonstrates that flame length may be stabilized even when the edge effects are reduced. For the thick PMMA plates, flames reached lengths up to 70 cm but were highly energetic and restricted by oxygen depletion. Tests with the Nomex fabric confirmed that the cyclic flame phenomena, observed in small facility tests, continued over longer sample. New features were also observed at the higher oxygen/pressure conditions available in the large chamber. Comparison of flame behavior between the two facilities under identical conditions revealed disparities, both qualitative and quantitative. This suggests that, in certain ranges of controlling parameters, chamber size and shape could be one of the parameters that affect the material flammability. If this proves to be true, it may limit the applicability of existing flammability data.

Kleinhenz, Julie↗

Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems

Purpose: To characterize stray radiation around the target volume in scanning proton therapy and study the performance of active neutron monitors. Methods: Working Group 9 of the European Radiation Dosimetry Group (EURADOS WG9—Radiation protection in medicine) carried out a large measurement campaign at the Trento Centro di Protonterapia (Trento, Italy) in order to determine the neutron spectra near the patient using two extended-range Bonner sphere spectrometry (BSS) systems. In addition, the work focused on acknowledging the performance of different commercial active dosimetry systems when measuring neutron ambient dose equivalents, H{sup ∗}(10), at several positions inside (8 positions) and outside (3 positions) the treatment room. Detectors included three TEPCs—tissue equivalent proportional counters (Hawk type from Far West Technology, Inc.) and six rem-counters (WENDI-II, LB 6411, RadEye™ NL, a regular and an extended-range NM2B). Meanwhile, the photon component of stray radiation was deduced from the low-lineal energy transfer part of TEPC spectra or measured using a Thermo Scientific™ FH-40G survey meter. Experiments involved a water tank phantom (60 × 30 × 30 cm{sup 3}) representing the patient that was uniformly irradiated using a 3 mm spot diameter proton pencil beam with 10 cm modulation width, 19.95 cm distal beam range, and 10 × 10 cm{sup 2} field size. Results: Neutron spectrometry around the target volume showed two main components at the thermal and fast energy ranges. The study also revealed the large dependence of the energy distribution of neutrons, and consequently of out-of-field doses, on the primary beam direction (directional emission of intranuclear cascade neutrons) and energy (spectral composition of secondary neutrons). In addition, neutron mapping within the facility was conducted and showed the highest H{sup ∗}(10) value of ∼51 μSv Gy{sup −1}; this was measured at 1.15 m along the beam axis. H{sup ∗}(10) values significantly decreased with distance and angular position with respect to beam axis falling below 2 nSv Gy{sup −1} at the entrance of the maze, at the door outside the room and below detection limit in the gantry control room, and at an adjacent room (<0.1 nSv Gy{sup −1}). Finally, the agreement on H{sup ∗}(10) values between all detectors showed a direct dependence on neutron spectra at the measurement position. While conventional rem-counters (LB 6411, RadEye™ NL, NM2-458) underestimated the H{sup ∗}(10) by up to a factor of 4, Hawk TEPCs and the WENDI-II range-extended detector were found to have good performance (within 20%) even at the highest neutron fluence and energy range. Meanwhile, secondary photon dose equivalents were found to be up to five times lower than neutrons; remaining nonetheless of concern to the patient. Conclusions: Extended-range BSS, TEPCs, and the WENDI-II enable accurate measurements of stray neutrons while other rem-counters are not appropriate considering the high-energy range of neutrons involved in proton therapy.

07 ISOTOPE AND RADIATION SOURCES↗

STS-113/11A: Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned in December 2002 and in May 2003 aboard Soyuz 5

The toxicological assessments of grab sample canisters (GSCs) returned aboard STS-l13 and Soyuz 5 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSCs were 79-120% except as noted in the table. One sample was returned with the valve opened. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) has leaked from heat-exchange units in large quantities, so its concentration is tracked separately. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. The table shows that the air quality in general was acceptable for crew respiration through the middle of December 2002. No conclusions can be made about the air quality after that date due to NASA's inability to return air samples from the ISS . Alcohols are not being controlled to the recently lowered guideline of 5 mg/m3, which was recommended to protect the water recovery systems. The airlock sample was taken during the regeneration of Met ox canisters in the adjacent Node. The trace pollutants were not increased above background; however, inspection of table 1 in the appendix shows a CO2 concentration of 17,000 mg/cu m, which is a relatively high concentration, but still below the 24-hour SMAC of23,000 mg/cu m. The control of OFP continues to be adequate at least through December 2002. Formaldehyde concentrations suggest that the high levels that were being found in the Lab atmosphere have subsided. This is probably attributable to the restoration of IMV in early February 2003 . Before the obstructing material was removed from ducts the Lab formaldehyde concentrations approached 0.06 mg/cu m, whereas after the repair the levels were near 0.04 mg/m3 . This does not mean that local sources in the Lab have been reduced, only that the excess of formaldehyde produced in the Lab is distributed into the whole volume of the ISS.

James, John T.↗

Temporal Characterization of Hydrates System Dynamics beneath Seafloor Mounds. Integrating Time-Lapse Electrical Resistivity Methods and In Situ Observations of Multiple Oceanographic Parameters

This study was designed to investigate temporal variations in hydrate system dynamics by measuring changes in volumes of hydrate beneath hydrate-bearing mounds on the continental slope of the northern Gulf of Mexico, the landward extreme of hydrate occurrence in this region. Direct Current Resistivity (DCR) measurements were made contemporaneously with measurements of oceanographic parameters at Woolsey Mound, a carbonate-hydrate complex on the mid-continental slope, where formation and dissociation of hydrates are most vulnerable to variations in oceanographic parameters affected by climate change, and where changes in hydrate stability can readily translate to loss of seafloor stability, impacts to benthic ecosystems, and venting of greenhouse gases to the water-column, and eventually, the atmosphere. We focused our study on hydrate within seafloor mounds because the structurally-focused methane flux at these sites likely causes hydrate formation and dissociation processes to occur at higher rates than at sites where the methane flux is less concentrated and we wanted to maximize our chances of witnessing association/dissociation of hydrates. We selected a particularly well-studied hydrate-bearing seafloor mound near the landward extent of the hydrate stability zone, Woolsey Mound (MC118). This mid-slope site has been studied extensively and the project was able to leverage considerable resources from the team’s research experience at MC118. The site exhibits seafloor features associated with gas expulsion, hydrates have been documented at the seafloor, and changes in the outcropping hydrates have been documented, photographically, to have occurred over a period of months. We conducted observatory-based, in situ measurements to 1) characterize, geophysically, the sub-bottom distribution of hydrate and its temporal variability, and 2) contemporaneously record relevant environmental parameters (temperature, pressure, salinity, turbidity, bottom currents) to detect short-term changes within the hydrates system, identify relationships/impacts of local oceanographic parameters on the hydrates system, and improve our understanding of how seafloor instability is affected by hydrates-driven changes. A 2009 DCR survey of MC118 demonstrated that we could image resistivity anomalies to a depth of 75m below the seafloor in water depths of 1km. We reconfigured this system to operate autonomously on the seafloor in a pre-programmed mode, for periods of months. We designed and built a novel seafloor lander and deployment capability that would allow us to investigate the seafloor at potential deployment sites and deploy instruments only when conditions met our criteria. This lander held the DCR system, controlling computers, and battery power supply, as well as instruments to record oceanographic parameters. During the first of two cruises to the study site, we conducted resistivity surveying, selected a monitoring site, and deployed the instrumented lander and DCR, centered on what appeared to be the most active locations within the site, programmed to collect a DCR profile, weekly. After a 4.5-month residence on the seafloor, the team recovered all equipment. Unfortunately, several equipment failures occurred prior to recovery of the instrument packages. Prior to the failures, however, two resistivity profiles were collected together with oceanographic data. Results show, unequivocally, that significant changes can occur in both hydrate volume and distribution during time periods as brief as one week. Occurrences appear to be controlled by both deep and near-surface structure. Results have been integrated with seismic data from the area and show correspondence in space of hydrate and structures, including faults and gas chimneys.

58 GEOSCIENCES↗

Under conditions of large geometric miss, tumor control probability can be higher for static gantry intensity-modulated radiation therapy compared to volume-modulated arc therapy for prostate cancer

The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic–based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for the different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15 mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characteristics of Ultralow Aspect Ratio Toroidal Plasmas and Non-Solenoidal Startup and Edge Stability Studies at Near-Unity Aspect Ratio (Final Report)

This grant supported a long-term research and development program to explore the physics and technology of spherical tokamak (ST) plasma behavior at near-unity aspect ratio ( A ). The PEGASUS Toroidal Experiment is a university-scale ( R ) ~ 0.40 m, α ~ .35 m, I p ≤ 0.3 MA, B T ≤ 0.15 T) experiment that accesses A → 1, to provide large values of the normalized plasma current, I N = I p /α B T , or equivalently the toroidal field utilization factor I p / I TF . The research activities focused on: 1) developing the technique of Local Helicity Injection (LHI) as a viable means of initiating and growing an ST plasma without the use of a central solenoid; 2) exploring the equilibrium and stability properties of spherical tokamak plasmas at extremely low aspect ratio; and 3) obtaining new insights in the properties of the enhanced confinement H-mode regime at A ~ 1. The initial (Phase I) facility employed a unique high-stress central solenoid Ohmic for current drive and heating with simple magnet current waveforms. A subsequent major upgrade (Phase II) offered more flexible control of the plasma evolution along with a powerful LHI system for plasma initiation, heating and sustainment. The LHI technique consists of injection of high-density current streams into vacuum toroidal and vertical magnetic fields. These streams become unstable and support magnetic reconnection to allow the system to relax into a tokamak-like magnetic configuration. This program focused on: 1) development of electron current sources that provide sufficiently high injection currents in the challenging edge plasma region; 2) validation of theoretical limits to achievable I p arising from magnetic helicity and energy conservation plus absolute limits arising from relaxation to a minimal energy states; 3) tests of a power balance model to describe the evolution of the plasma current I p (t); and 4) study of magnetic fluctuations and their role in the I p evolution. This culminated in the production of toroidal currents of I p ≥ 0.2 MA with only ~8 kA of injected current. Operation with Ohmic induction alone in Phase I created plasmas with soft limits on the achievable I p and field utilization ( I p / I TF ~ 1) due to the onset of large low-order (2/1 or 3/2) internal resonant tearing modes. With the expanded capabilities in Phase II operation, methods employed to mitigate those modes and achieve I p / I TF > 1 were: 1) I TF ramp-downs; 2) non-solenoidal startup via LHI; and 3) extremely low I TF Ohmic operations assisted by LHI current injector pre-ionization. Extensive use of LHI-driven startup and drive for non-solenoidal operation produced favorable current profiles to stably operate tokamak plasmas with unprecedentedly high I N = I p / aB T ~ 15 and I p / I TF > 2. With strong reconnection-driven anomalous ion heating, this in turn provided access to tokamak plasmas with B t up to 100%, a world record 2 times higher than that previously achieved in advanced or spherical tokamaks. This high B t regime had a large fraction (~50%) of the plasma volume in a region of an absolute minimum- B configuration. The MHD stability limit in this regime was the ideal external kink mode without a stabilizing wall. These results provided the first demonstration of access to tokamak plasmas with very high B t , high i N , high elongation κ, and low internal inductance ℓ i , and as such served as a proof-ofprinciple for access to this long-sought ST regime. The naturally low B T needed for stability at A ≤ 1.2 reduces the L-H mode power threshold, P LH , so that H-mode plasmas were achieved with Ohmic heating alone. The power threshold for the transition to the H-mode regime was found to be 10× the accepted values from the ITER international scaling, confirming initial trends indicated by experiments on MAST and NSTX, and suggesting that the physics behind this transition is not yet fully understood. The density dependence of the transition and the observed insensitivity to whether the plasma is bounded by a limiter or magnetic divertor are consistent with the recent FM 3 model. Multiple unstable toroidal magnetic modes were measured during ELM (Edge Localized Mode) crashes, with generally lower toroidal mode numbers than seen at higher A , which was attributed to the larger peeling mode instability drive at low A . First-ever edge current profile measurements through an ELM crash showed current-carrying filaments were generated, as seen in ELM simulations and in electromagnetic blob transport theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements and Model Estimations of Viscosities of the MnO-CaO-SiO{sub 2}-MgO-Al{sub 2}O{sub 3} Melts

The viscosities of the MnO (0 to 55 mass pct)-CaO-SiO{sub 2}-MgO (5 mass pct)-Al{sub 2}O{sub 3} (20 mass pct) melts were measured by rotating cylinder method in the temperature range from 1573 K to 1873 K (1300 °C to 1600 °C). The measurements were carried out in the atmosphere of flowing CO/CO{sub 2} gas mixture with a volume ratio of 99/1, and molybdenum crucible and spindle were adopted. The results reveal that MnO is a viscosity reducing component, and the effect of MnO is more notable in the melts with higher ratio of CaO to SiO{sub 2}. For example, in the melts with the mass ratio of CaO to SiO{sub 2} equal to 0.6, the addition of 5 mass pct MnO only slightly reduced the viscosities. Comparatively, the addition of 5 mass pct MnO made the viscosities of the melts with the mass ratio of CaO to SiO{sub 2} equal to 1.0 and 1.5 decrease remarkably. Based on the measured data, the viscosities estimation model proposed in our previous study was extended to the system containing MnO, and the model parameters were determined. The model can estimate and predict the viscosities of the aluminosilicate melts containing MnO well, and then some iso-viscosity contours of this system were calculated. From the iso-viscosity contours, it can be seen that MnO is almost equivalent to CaO in reducing the viscosities in the melt with high SiO{sub 2} content, while with the decrease of the SiO{sub 2} content MnO becomes more effective than CaO.

36 MATERIALS SCIENCE↗

Gradient Compression Garments as a Countermeasure to Post-Space Flight Orthostatic Intolerance: Potential Interactions with the Maximum Absorbency Garment

Astronauts and cosmonauts may experience symptoms of orthostatic intolerance during re-entry, landing, and for several days post-landing following short- and long-duration spaceflight. Presyncopal symptoms have been documented in approximately 20% of short-duration and greater than 60% of long-duration flyers on landing day specifically during 5-10 min of controlled (no countermeasures employed at the time of testing) stand tests or 80 deg head-up tilt tests. Current operational countermeasures to orthostatic intolerance include fluid loading prior to and whole body cooling during re-entry as well as compression garments that are worn during and for up to several days after landing. While both NASA and the Russian space program have utilized compression garments to protect astronauts and cosmonauts traveling on their respective vehicles, a "next-generation" gradient compression garment (GCG) has been developed and tested in collaboration with a commercial partner to support future space flight missions. Unlike previous compression garments used operationally by NASA that provide a single level of compression across only the calves, thighs, and lower abdomen, the GCG provides continuous coverage from the feet to below the pectoral muscles in a gradient fashion (from approximately 55 mm Hg at the feet to approximately 16 mmHg across the abdomen). The efficacy of the GCG has been demonstrated previously after a 14-d bed rest study without other countermeasures and after short-duration Space Shuttle missions. Currently the GCG is being tested during a stand test following long-duration missions (~6 months) to the International Space Station. While results to date have been promising, interactions of the GCG with other space suit components have not been examined. Specifically, it is unknown whether wearing the GCG over NASA's Maximum Absorbency Garment (MAG; absorbent briefs worn for the collection of urine and feces while suited during re-entry and landing) will interfere with the effectiveness of the GCG or conversely whether the GCG will reduce the fluid absorption capabilities of the MAG. Methods: This operational, directed study, will (1) determine whether the effectiveness of the GCG is affected by the MAG with regard to cardiovascular responses to head-up tilt, the standard orthostatic intolerance test employed for astronauts and bed rest subjects; (2) determine whether the effectiveness of the MAG is compromised by the GCG tested by injecting a standard fluid volume (950 ml in 3 separate simulated "urine voids") at a standardized rate (30 ml/sec); and (3) determine whether comfort is affected by wearing the MAG under the GCG using a standardized questionnaire. Results from this study will guide future development and operational use of the GCG and MAG to maximize crew health, safety, and comfort.

Lee, S. M. C.↗

Tumor control probability and the utility of 4D vs 3D dose calculations for stereotactic body radiotherapy for lung cancer

Four-dimensional (4D) dose calculations for lung cancer radiotherapy have been technically feasible for a number of years but have not become standard clinical practice. The purpose of this study was to determine if clinically significant differences in tumor control probability (TCP) exist between 3D and 4D dose calculations so as to inform the decision whether 4D dose calculations should be used routinely for treatment planning. Radiotherapy plans for Stage I-II lung cancer were created for 8 patients. Clinically acceptable treatment plans were created with dose calculated on the end-exhale 4D computed tomography (CT) phase using a Monte Carlo algorithm. Dose was then projected onto the remaining 9 phases of 4D-CT using the Monte Carlo algorithm and accumulated onto the end-exhale phase using commercially available deformable registration software. The resulting dose-volume histograms (DVH) of the gross tumor volume (GTV), planning tumor volume (PTV), and PTV{sub setup} were compared according to target coverage and dose. The PTV{sub setup} was defined as a volume including the GTV and a margin for setup uncertainties but not for respiratory motion. TCPs resulting from these DVHs were estimated using a wide range of alphas, betas, and tumor cell densities. Differences of up to 5 Gy were observed between 3D and 4D calculations for a PTV with highly irregular shape. When the TCP was calculated using the resulting DVHs for fractionation schedules typically used in stereotactic body radiation therapy (SBRT), the TCP differed at most by 5% between 4D and 3D cases, and in most cases, it was by less than 1%. We conclude that 4D dose calculations are not necessary for most cases treated with SBRT, but they might be valuable for irregularly shaped target volumes. If 4D calculations are used, 4D DVHs should be evaluated on volumes that include margin for setup uncertainty but not respiratory motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intermediate-Scale Hydraulic Fracturing in a Deep Mine - kISMET Project Summary 2016

In support of the U.S. DOE SubTER Crosscut initiative, we established a field test facility in a deep mine and designed and carried out in situ hydraulic fracturing experiments in the crystalline rock at the site to characterize the stress field, understand the effects of rock fabric on fracturing, and gain experience in monitoring using geophysical methods. The project also included pre- and post-fracturing simulation and analysis, laboratory measurements and experiments, and we conducted an extended analysis of the local stress state using previously collected data. Some of these activities are still ongoing. The kISMET (permeability (k) and Induced Seismicity Management for Energy Technologies) experiments meet objectives in SubTER’s “stress” pillar and the “new subsurface signals” pillar. The kISMET site was established in the West Access Drift of SURF 4850 ft (1478 m) below ground (on the 4850L) in phyllite of the Precambrian Poorman Formation. We drilled and cored five near-vertical boreholes in a line on 3 m spacing, deviating the two outermost boreholes slightly to create a five-spot pattern around the test borehole centered in the test volume at ~1528 m (5013 ft). Laboratory measurements of core from the center test borehole showed P-wave velocity heterogeneity along each core indicating strong, fine-scale (~1 cm or smaller) changes in the mechanical properties of the rock. The load-displacement record on the core suggests that the elastic stiffness is anisotropic. Tensile strength ranges between 3-7.5 MPa and 5-12 MPa. Permeability measurements are planned, as are two types of laboratory miniature hydraulic fracturing experiments to investigate the importance of rock fabric (anisotropy and heterogeneity) on near-borehole hydraulic fracture generation. Pre-fracturing numerical simulations with INL’s FALCON discrete element code predicted a fracture radius of 1.2 m for a corresponding injection volume of 1.2 L for the planned fractures, and negligible microseismicity. Field measurements of the stress field by hydraulic fracturing showed that the minimum horizontal stress at the kISMET site averages 21.7 MPa (3146 psi) pointing approximately N-S (356 degrees azimuth) and plunging slightly NNW at 12°. The vertical and horizontal maximum stress are similar in magnitude at 42-44 MPa (6090-6380 psi) for the depths of testing which averaged approximately 1530 m (5030 ft). Hydraulic fractures were remarkably uniform suggesting core-scale and larger rock fabric did not play a role in controlling fracture orientation. Monitoring using ERT and CASSM in the four monitoring boreholes, and passive seismic accelerometer-based measurements in the West Access Drift, was carried out during the generation of a larger fracture (so-called stimulation test) at a depth of 40 m below the invert. ERT was not able to detect the fracture created, nor were the accelerometers in the drift, but microseismicity was detected for first (deepest) hydraulic-fracturing stress measurement. The CASSM data have not yet been analyzed. Analytical solutions suggest fracture radius of the large fracture (stimulation test) was more than 6 m, depending on the unknown amount of leak-off. The kISMET results for stress state are consistent with large-scale mid-continent estimates of stress. Currently we are using the orientation of the stress field we determined to interpret a large number of borehole breakouts recorded in nearby boreholes at SURF to generate a more complete picture of the stress field and its variations at SURF. The efforts on the project have prompted a host of additional follow-on studies that we recommend be carried out at the kISMET site.

02 PETROLEUM↗

Colorimetric Solid Phase Extraction (CSPE): Using Color to Monitor Spacecraft Water Quality

In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS). The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was launched as a Station Development Test Objective (SDTO) experiment to evaluate the suitability of CSPE technology for routine use monitoring water quality on the ISS. CSPE is a sorption-spectrophotometric technique that combines colorimetric reagents, solid-phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water samples. In CSPE, a known volume of sample is metered through a membrane disk that has been impregnated with an analyte-specific colorimetric reagent and any additives required to optimize the formation of the analyte-reagent complex. As the sample flows through the membrane disk, the target analyte is selectively extracted, concentrated, and complexed. Formation of the analyte-reagent complex causes a detectable change in the color of the membrane disk that is proportional to the amount of analyte present in the sample. The analyte is then quantified by measuring the color of the membrane disk surface using a hand-held diffuse reflectance spectrophotometer (DRS). The CWQMK provides the capability to measure the ionic silver (Ag +) and molecular iodine (I2) in water samples on-orbit. These analytes were selected for the evaluation of CSPE technology because they are the biocides used in the potable water storage and distribution systems on the ISS. Biocides are added to the potable water systems on spacecraft to inhibit microbial growth. On the United States (US) segment of the ISS molecular iodine serves as the biocide, while the Russian space agency utilizes silver as a biocide in their systems. In both cases, the biocides must be maintained at a level sufficient to control bacterial growth, but low enough to avoid any negative effects on crew health. For example, the presence of high levels of iodine in water can cause taste and odor issues that result in decreased water consumption by the crew. There are also concerns about potential impacts on thyroid function following exposure to high levels of iodine. With silver, there is a risk of developing argyria, an irreversible blue-gray discoloration of the skin, associated with long term consumption of water containing high concentrations of silver. The need to ensure that safe, effective levels of biocide are maintained in the potable water systems on the ISS provides a perfect platform for evaluating the suitability of CSPE technology for in-flight water quality monitoring. This paper provides an overview of CSPE technology and details on the silver and iodine methods used in the CWQMK. It also reports results obtained during in-flight analyses performed with the CWQMK and briefly discusses other potential applications for CSPE technology in both the spacecraft and terrestrial environments.

Gazda, Daniel B.↗

Hydrogen Sensor for Parabolic Trough Expansion Tanks

The National Renewable Energy Laboratory and Acciona Energy North America are developing and implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. We are pursuing a method that selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid. As part of this effort, we are developing a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. During previous work, we demonstrated that our sensor design measures hydrogen levels over a wide partial pressure range from 1.33 mbar down to 0.003 mbar with an accuracy of +/-20%. We acquired these results under limited conditions because we measured hydrogen partial pressure in gas mixtures of hydrogen and nitrogen only. In this paper, we report our most recent results in which we measured hydrogen partial pressures in gas mixtures that contain hydrogen, nitrogen, biphenyl, and diphenylether. Our results for this gas mixture were essentially the same as those obtained for the hydrogen/nitrogen mixture only, and they also had the same accuracy of +/-20%. This level of accuracy is sufficient to evaluate the performance of a hydrogen mitigation process because hydrogen partial pressure in the expansion tank decreases more than an order of magnitude when the mitigation process is operating. We examined the palladium/silver membrane after completing these measurements and did not observe any signs of membrane deterioration or contamination due to exposure to biphenyl and diphenylether at 405 degrees C. The membrane for these tests was 25 um thick. For the next sensor design that we are developing in 2018, we are using a membrane that is 127 um thick. This thickness is required for the membrane to withstand the 150 psi pressure drop across the membrane when exposed to actual headspace gas from the expansion tank. We performed initial tests in which we exposed a 127-um-thick palladium alloy membrane to 400 degrees C and 150 psi pressure drop and observed no signs of failure or gas leakage. Finally, we developed a transient model that accounts for hydrogen transport mechanisms within the sensor when measurements are made. Our model accounted for hydrogen diffusion through the boundary layer that is adjacent to the membrane and for hydrogen permeation across the membrane and into the permeate volume. Our modeling results agreed very closely with our experimental data when we assumed a boundary-layer thickness of 0.2 cm. This thickness is within the range of expected thicknesses for this gas composition, temperature, and pressure at minimum flowrate. Our model results showed that hydrogen diffusion through the boundary layer adjacent to the membrane is the rate-determining step for the transient pressure response when measuring hydrogen partial pressure.

14 SOLAR ENERGY↗

Polarized 3He gas circulating technologies for neutron analyzers

We outline our project to develop a circulating polarized helium-3 system for developing of large, quasi-continuously operating neutron analyzers. The project consisted of four areas: 1) Development of robust external cavity narrowed diode laser output with spectral line width < 0.17 nm and power of 2000 W. 2) Development of large glass polarizing cells using cell surface treatments to obtain long relaxation lifetimes. 3) Refinements of the circulation system with an emphasis on gas purification and materials testing. 4) Design/fabrication of a new polarizer system. 5) Preliminary testing of the new polarizer. 1. Developed Robust High-Power Narrowed Laser The optical configuration of the laser was discussed in the proposal and will be reviewed in the body of this report. The external cavity is configured to mutually lock the wavelength of five 10-bar laser stacks. All the logistical milestones were been met and critical subsystems- laser stack manifold and power divider, external laser cavity, and output telescope- were assembled and tested at low power. Each individual bar is narrowed to ~0.05 nm; when combined the laser has a cumulative spectral width of 0.17 nm across the entire beam due to variations of the bars central wavelength by +/- 0.1 nm, which is similar to that of Volume Bragg Grating narrowed laser bars. This configuration eliminates the free-running “pedestal” that occurs in other external cavity diode lasers. The full-scale laser was completed in 2016 and was used in both the older and newer helium polarizers. This laser was operated at 75% power for periods of up to 8 hours. Once installed, the spectrum became slightly broader (~.25 nm) at full power; this is likely due to very slight misalignments that occurred during handling. 2. Developed the processes to create uniform sintered sol-gel coatings. Our work on cell development comprised: 1) Production of large GE180 cells and explore different means of cell preparation, and 2) Development of apply sol-gel coatings to the interior of both borosilicate and aluminosilicate cells. We applied six sol-gel coatings. By modifying the mixture and developing procedures to drain and dry the cell, we produced visually uniform coatings on the interior of the cells. We now have perfected that process as described below in our report. We were able to accelerate the testing of cells using an ex situ method that avoids installing each cell into a polarizer. In the project’s last year, we conducted 38 external tests of 8 different cells. We also installed two sol-gel coated cells in our polarizers. We created cell with long ex situ relaxation lifetimes, one of which exceeded 40 hours. However, when installed in the polarizer the measured lifetime is 8 hours or less. 3. Demonstrated cycling of polarized gas and ex situ cell testing We are now cycling polarized gas from the polarizer to glass vessels and back. This has allowed us, for the first time, to make ex situ T1 measurements of polarizing cells without installing them into the polarizer itself. This has greatly improved our productivity in producing cells and evaluating our cell preparation processes. We continued development of the gas handling system in parallel with fabricating new polarizer. The integrated system was tested by the end of 2016. We now regularly cycle gas into and out of the polarizer. 4. Completed new polarizer infrastructure and control systems. We completed the new polarizer infrastructure in November 2016. The polarizer subsystems are 1) the frame, 2) the oil flow system, 3) the gas handling system, 4) the pressure vessel, with embedded solenoid, 5) cell mounting hardware with heat spreaders, and 6) electrical power and instrumentation. 5. Carried out initial tests of polarizer. We completed initial testing of the polarizer in April and May of 2017. These tests were carried out for periods up to 6 hours with laser power between 750 and 1300 Watts. The laser performed well and the polarization with asymptotic to 45 percent, which was below expectations. This low value resulted from a stationary thermal inversion in the cell that caused most of the laser power to be absorbed near the laser inlet window and deprived the lower portions of the cell of pumping laser light. Possible solutions to this problem include enhanced cooling of the cell near the laser entry and slight detuning of the laser. 6. Ongoing work. Our polarizer development efforts are ongoing to pursue our interest in neutron analyzers, nuclear targets, and providing helium for medical imaging. Current tests in the pipeline include: 1. Testing cooling enhancements to improve laser penetration of spectrally narrow lasers; 2. Testing of a cell with isolation valves that minimizes diffusive contact with gas handling hardware during polarization; 3. Testing of smaller hybrid cells with reduced alkali loading; 4. Producing polarized helium-3 for MRI imaging at the University of Missouri.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prompt-gamma detection towards absorbed energy monitoring during hadrontherapy

Hadrontherapy is an emerging technique which exploits the fact that a large quantity of the energy of the incident particles is deposited at the end of their flight path. This allows a conformation of the applied dose to the tumor volume and a simultaneous sparing of surrounding healthy tissue. A real-time control of the ion range during the treatment is possible via the detection of prompt secondary radiation (gamma rays or charged particles). Besides a monitoring of the ion range, the knowledge of the total energy absorbed inside the patient is also of importance for an improvement of the treatment quality. It has been shown that the ambient dose in a treatment room is correlated to the monitoring units, i.e. the number of protons of the beam delivery system. The present study consists in applying time-of-flight (TOF) information to identify prompt gamma-rays generated by interactions inside the patient which provides a direct information on the energy imparted. Results from test measurements will be given, which show that events generated in the nozzle and the target phantom can be discriminated. Furthermore, a standalone detection system is being developed which will be read out by a standard PC. The status of the developments for the corresponding electronics will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Environmental Stress Testing of the Single Sample Cylinder: A Proven Consensus Standard for Internal Gas Analysis (IGA) or Residual Gas Analysis (RGA)

In August 2008, Schuessler Consulting was contracted by NASA GSFC in support of the NASA Electronic Parts and Packaging (NEPP) program to perform two separate studies on moisture laden air in a stainless steel cylinder that had been designed to become a consensus standard for Test Method 1018. This Test Method was originally released for hybrids under Mil. Std. 883 but was quickly utilized on other microelectronic devices under the auspice of Mil. Std. 750. The cylinder had subsequently been fabricated for the 750 community. It was back-filled with moist air and subsequently analyzed over a period of time under a previous NASA contract. It had been shown that moisture in the 4000 - 5000 ppm range could be analyzed rather precisely with a mass spectrometer, commonly referred to as a Residual Gas Analyzer (RGA). The scope of this study was to ascertain if the composition and precision varied as a function of thermal shock at sub-zero temperatures and whether there was consensus when the standard was submitted to other RGA units. It was demonstrated and published that the consensus standard would yield precise RGA data for moisture within +/- 1% when optimized for a given RGA unit. It has been subsequently shown in this study at Oneida Research Services, that sub-zero storage did not affect that precision when a well-defined protocol for the analysis was followed. The consensus standard was taken to a second facility for analysis where it was found that moisture adsorption on the transfer lines caused precision to drop to +/- 12%. The Single Sample Cylinder (SSC) is a one liter stainless steel cylinder with associated sampling valves and has considerable weight and volume. But this considerable size allows for approximately 300 gas samples of the same composition to be delivered to any RGA unit. Lastly, a smaller cylinder, approximately 75 cc, of a second consensus standard was fabricated and tested with a different mix of fixed gases where moisture was kept in the 100 ppm range. This second standard has the potential of providing 30 gaseous samples and can be readily shipped to any analytical facility that desires to generate comparison RGA data. A series of comparison residual gas analyses was performed at the Honeywell Federal Manufacturing & Technologies facility in the National Nuclear Facility Administration s plant in Kansas City to complete this project. It was shown that improvements in the precision of a given RGA unit can be done by controlling the cycle time for each analysis and increasing analysis temperatures to minimize moisture adsorption. It was also found that a "one time event" in the subzero storage of the large SSC did not effect the units ability to continuously supply precise samples of the same chemistry, however the "event" caused a permanent +8% shift in the reported value of the moisture content. Lastly, a set of SSC RGA results was plotted on a common graph with DSCC "correlation study" RGA data. The result demonstrates the ability of the SSC to remove many of the individual variances that single, individual samples introduce. The consensus standards are now in storage at Oneida Research Services, one of the DSCC certified houses that does RGA to Military Standards, where they await future studies. The analytical data and the operational parameters of the instruments used are provided in the following discussion. Limitations and suggested means for improvement of both precision and accuracy are provided.

Schuessler, Philipp WH↗

Atomic-Scale Surface Studies of Bulk Metallic Glasses. Final Report

Bulk metallic glasses (BMGs) are of both scientific and technological interest because the absence of periodic atomic arrangements provides them with unique physical, chemical, and mechanical properties. Their high strength, superior elasticity, and an ability to be easily formed into virtually unlimited shapes with feature sizes from centimeters to Angstroms by blow molding and thermoplastic forming makes them an attractive choice for more and more practical applications and products. Due to their complex internal structure, however, experiments that yield insight into their exact atomic arrangements have been scarce. As a result, glass physics is one of the last remaining unexplored fields of materials science despite the scientific and technological importance of glasses in our daily lives, and the question how to characterize and control matter away from equilibrium, as glasses are, was listed as one of five Grand Challenges in a recent DoE report. The main reason for the slow progress in glass physics is the lack of experimental tools that enable access to atomic-scale structural and behavioral information for disordered materials. Such atomic-scale knowledge is mandatory to establish structure-property relationships that ultimately could allow to custom-design alloys featuring specific desired characteristics. With no such relationships available, theory development in glass remains basic and the few that exist are often untested. The aim of this research was to enable progress in our understanding of BMGs by developing a new approach that will allow a meaningful application of local surface science methods to specially prepared BMG samples to obtain a wealth of quantitative information on their atomic arrangements. Key was the availability of specially prepared samples whose surfaces feature large atomically flat terraces despite being entirely amorphous, which we have produced from a Pt 57.5 Cu 14.7 Ni 5.3 P 22.5 alloy (‘Pt-BMG’) both under ambient conditions as well as in ultrahigh vacuum using a unique setup that has been specially developed within this grant. Our approach starts with the in-situ preparation of oxide crystals that are terminated by large terraces, from which exact mirror images out of BMG will be produced using thermoplastic forming (TPF); for the research within this grant, we have successfully used (001)-oriented SrTiO 3 single crystal surfaces as well as (100)-, (110)-, and (111)-oriented single crystals made from LaAlO 3 . Since the resulting BMG replicas display all features of the original crystal with sub-Angstrom fidelity, thereby mimicking the original crystal’s termination by atomically flat terraces without being crystalline themselves, they are ideally suited for further investigation. The following atomic-scale local studies were then carried within this proposal: (i) high-resolution surface imaging and local spectroscopy using scanning probe microscopy, which showed disordered atom-like features and revealed changes in the gradient of the local surface potential on a 1-2 nm length scale; (ii) characterization of atomic-scale plastic flow with affected volumes as low as 1000 atoms, which showed local hardness near or above the theoretically predicted maximum and, once plastic deformation was initiated, homogeneous flow of the atoms involved; (iii) characterization of surface relaxation processes and the onset of crystallization induced by annealing, which showed that upon heating over the material’s glass transition temperature, the surface rearranges and relaxes towards a more stable, denser packed glass, which increases on-terrace surface roughness, while surface tension smoothens step edges; and (iv) studies that investigate the dependence of the material’s mechanical properties and structure on processing parameters, revealing that relaxed glasses get denser, harder, and more elastic. In combination, this information allows to combine structural models with mechanical properties and preparation history, thereby facilitating the development of preparation-structure-property relationships for metallic glasses. With the availability of such information, bulk metallic glasses can be further optimized to be used in more and more applications in industry.

36 MATERIALS SCIENCE↗

Simulation of a Periodic Jet in a Crossflow with a RANS Solver Using an Unstructured Grid

A second-order unstructured-grid code, developed and used primarily for steady aerodynamic simulations, is applied to the synthetic jet in a cross flow. The code, FUN3D, is a vertex-centered finite-volume method originally developed by Anderson[1, 2], and is currently supported by members of the Fast Adaptive Aerospace Tools team at NASA Langley. Used primarily for design[3] and analysis[4] of steady aerodynamic configurations, FUN3D incorporates a discrete adjoint capability, and supports parallel computations using MPI. A detailed description of the FUN3D code can be found in the references given above. The code is under continuous development and contains a variety of flux splitting algorithms for the inviscid terms, two methods for computing gradients, several turbulence models, and several solution methodologies; all in varying states of development. Only the most robust and reliable components, based on experiences with steady aerodynamic simulations, were employed in this work. As applied in this work, FUN3D solves the Reynolds averaged Navier-Stokes equations using the one equation turbulence model of Spalart and Allmaras[5]. The spatial discretization is formed on unstructured meshes using a vertex-centered approach. The inviscid terms are evaluated by a flux-difference splitting formulation using least-squares reconstruction and Roe-type approximate Riemann fluxes. Green-Gauss gradient evaluations are used for viscous and turbulence modeling terms. The discrete spatial operator is combined with a backward time operator which is then solved iteratively using point or line Gauss-Seidel and local time stepping in a pseudo time. For steady flows, the physical time step is set to infinity and the pseudo time step is ramped up with the iteration count. A second-order backward in time operator is used for time accurate flows with 20 to 50 steps in the pseudo time applied at each physical time step. For this effort, FUN3D was modified to support spatially varying boundary and initial conditions, and unsteady boundary conditions. Also, a specialized in/out flow boundary condition was implemented to model the action of the diaphragm. This boundary condition is described below in more detail. The grids were generated using the internally developed codes GridEX[6] for meshing the surfaces and inviscid regions of the domain, and for CAD access; and MesherX[7] for meshing the viscous regions. Grid spacing in on the surfaces and in the inviscid regions are indirectly controlled by specifying sources. The viscous layers are generated using an advancing layer technique. MeshersX allows the user to control the spatial variation of the first step off the surface, growth rates, and the termination criterion by providing small problem dependent subroutines.

Atkins, H. L.↗