Search NASA⌕ Search

SEARCH · Search NASA

Results for “data driven operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

A Business Case for Nuclear Plant Control Room Modernization

This paper presents a generic business case for implementation of technology that supports Control Room Modernization (CRM). The analysis presented in two forms; 1) a standalone technology upgrade, and 2) a technology upgrade that is built upon and incremental to a prior business case created for Mobile Work Packages (MWP). The business case contends that advanced communication and networking and analytical technologies will allow NPP to conduct control room operations with improved focus by reducing human factors and redundant manpower, and therefore operate with fewer errors. While some labor savings can be harvested in terms of overtime, the majority of savings are demonstrated as reduced time to take the plant off line and bring back on line in support of outages. The benefits are quantified to a rough order of magnitude that provides directional guidance to NPPs that are interested in developing a similar business case. This business case focuses on modernization of the operator control room and does not consider a complete overhaul and modernization of a plants instrument and control systems. While operators may be considering such an investment at their plants, the sizable capital investment required is not likely supported by a cost/benefit analysis alone. More likely, it is driven by obsolescence and reliability issues, and requires consideration of mechanical condition of plant systems, capital depreciation, financing, relicensing and overall viability of the plant asset over a 20-year horizon in a competitive market. Prior studies [REF] have indicated that such a modernization of plant I&C systems, alone or as part of a larger modernization effort, can yield very significant reductions in O&M costs. However, the depth of research and analysis required to develop a meaningful business case for a plant modernization effort is well beyond the scope of this study. While CRM as considered in this study can be easily integrated as part of grander plant modernization effort, it can also be considered as a stand-alone project, implemented as a supervisorial layer over and above existing systems. CRM is enabled by a suite of technologies, which are described in further detail in the body of this report. They include: • Modernized control room with interactive displays • High-bandwidth wireless networks • Mobile devices • Component identification technology • Mobile wireless video cameras • Smart or task based operator displays • Computer-Based Procedures (CBP)/Automated Mobile Work Packages (MWP) • Intelligent plant configuration • Advanced data analytics An analysis was conducted to determine how these technologies might impact outage operations at an NPP. The analysis concluded that outage management capabilities would be improved with application of these technologies, and result in annual benefits for the plant. These improved capabilities were identified and described in further detail in this report. • Reduction in need redundant manpower (verification, etc) • Improved critical path shutdown and restart duration during outages • Reduction in human factors and errors • Remote watches • Paperless outage coordination • Bulk work optimization

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of Seasonal Snow-Cover Change on the Observed and Simulated State of the Atmospheric Boundary Layer in a High-Altitude Mountain Valley

The structure and evolution of the atmospheric boundary layer (ABL) under clear-sky fair weather conditions over mountainous terrain is dominated by the diurnal cycle of the surface energy balance and thus strongly depends on surface snow cover. We use data from three passive ground-based infrared spectrometers deployed in the East River Valley in Colorado's Rocky Mountains to investigate the response of the thermal ABL structure to changes in surface energy balance during the seasonal transition from low to high snow cover. Temperature profiles were retrieved from the infrared radiances using the optimal estimation physical retrieval Tropospheric Remotely Observed Profiling via Optimal Estimation. A nocturnal surface inversion formed in the valley during clear-sky days, which was subsequently mixed out during daytime with the development of a convective boundary layer when snow cover was low. Over high snow cover, a very shallow convective boundary layer formed, above which the inversion persisted through the daytime hours. We compare these observations to NOAA's operational High-Resolution-Rapid-Refresh model and find large warm biases on clear-sky days resulting from the model's inability to form strong nocturnal inversions and to maintain the stable stratification in the valley during daytime when there was snow on the ground. We suggest several factors contributing to the large model errors. These are (a) the inability of the model to represent well-developed thermally driven flows likely due to the too coarse horizontal grid spacing (3 km), (b) too much convective mixing during daytime, and (c) too strong vertical coupling between the valley atmosphere and the free troposphere.

54 ENVIRONMENTAL SCIENCES↗

ThermoLift – A Natural Gas Fired Air Conditioner and Heat Pump

ThermoLift is developing TC-Cycle™, a natural-gas driven air conditioner and cold-climate heat pump that can provide space heating, water heating, and air conditioning in a single device. Unlike traditional heat-pump system, the TC-Cycle system uses helium as working fluid in place of high global warming potential HFC refrigerant. The system has broad application as a combined HVAC solution and technology development throughout this program has advanced the Technology Readiness Level (TRL) from TRL-1 to TRL-5 achieved in the Gen 3.0 prototype. In August of 2013, the US Department of Energy (DOE) provided Research and Development funding through the Building Technologies Innovations Program Funding Opportunity Announcement DE-FOA-0000823. The statement of work (SOW) outlined a deliverable of testing at ORNL and a final test report prepared to include various heating cooling temperature ranges and performance analysis. Furthermore, a milestone of this effort was to analyze all test data to establish further efficiency improvements and consider optimum manufacturing methodologies to facilitate the next level improvements. ThermoLift’s Gen 3.0 gas-fired heat pump was shipped and installed into ORNL’s test facility with most of the data reported herein obtained on August 6, 2018. Uninterrupted operation demonstrated cycle Coefficient of Performance (COP) well exceeding DOE targets for cold-climate heat pumps. Furthermore, there was no degradation in capacity as inlet (ambient) temperature decreased.

03 NATURAL GAS↗

Floating photovoltaic power plants: A review of energy yield, reliability, and operation and maintenance

Photovoltaic (PV) systems are essential for the transition to sustainable energy, reducing fossil fuel dependence and mitigating climate change. Although PV requires minimal land area — PV can meet the European Union's energy needs using only 0.26% of its land — space for deployment is often scarce in densely populated regions. Floating photovoltaics (FPV) offer an effective solution to land-use challenges by installing PV systems on floating structures in water bodies. FPV is a growing niche within PV with a cumulative installed capacity reaching 7.7 GW globally by 2023. Almost 90% of the installed FPV capacity is in Asia, with close to 50% of in China alone, while the Netherlands and France are the largest markets outside Asia. FPV shows strong potential to support climate targets, but still faces challenges like regulatory barriers, cost competitiveness compared to ground-based PV (GPV), and uncertainties about environmental impacts and system reliability. FPV systems are currently installed mainly on sheltered inland waters, such as quarry lakes, irrigation ponds and reservoirs. FPV technical standards are still being developed. Guidelines have been published by the World Bank, DNV, and Solar Power Europe, and emerging national standards from South Korea, China, and Singapore address design, components, and safety. The International Electrotechnical Commission (IEC) is working on formal standards for floats, mooring systems, and electrical connectors. However, the published best practices lack quantitative guidance for yield modelling and reliability, which this report aims to address. It provides data-driven insights, models, and parameters essential for accurate energy yield, reliability, and maintenance predictions over FPV systems' lifetimes.

14 SOLAR ENERGY↗

A theory of dark pions

We present a complete model of a dark QCD sector with light dark pions, broadly motivated by hidden naturalness arguments. The dark quarks couple to the Standard Model via irrelevant Z- and Higgs-portal operators, which encode the low-energy effects of TeV-scale fermions interacting through Yukawa couplings with the Higgs field. The dark pions, depending on their CP properties, behave as either composite axion-like particles (ALPs) mixing with the Z or scalars mixing with the Higgs. The dark pion lifetimes fall naturally in the most interesting region for present and proposed searches for long-lived particles, at the LHC and beyond. This is demonstrated by studying in detail three benchmark scenarios for the symmetries and structure of the theory. Within a coherent framework, we analyze and compare the GeV-scale signatures of flavor-changing meson decays to dark pions, the weak-scale decays of Z and Higgs bosons to hidden hadrons, and the TeV-scale signals of the ultraviolet theory. New constraints are derived from B decays at CMS and from Z-initiated dark showers at LHCb, focusing on the displaced dimuon signature. We also emphasize the strong potential sensitivity of ATLAS and CMS to dark shower signals with large multiplicities and long lifetimes of the dark pions. As a key part of our phenomenological study, we perform a new data-driven calculation of the decays of a light ALP to exclusive hadronic Standard Model final states. The results are provided in a general form, applicable to any model with arbitrary flavor-diagonal couplings of the ALP to fermions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Representing Small Commercial Building Faults in EnergyPlus, Part I: Model Development

Small commercial buildings (those with less than approximately 1000 m2 of total floor area) often do not have access to cost-effective automated fault detection and diagnosis (AFDD) tools for maintaining efficient building operations. AFDD tools based on machine-learning algorithms hold promise for lowering cost barriers for AFDD in small commercial buildings; however, such algorithms require access to high-quality training data that is often difficult to obtain. To fill the gap in this research area, this study covers the development (Part I) and validation (Part II) of fault models that can be used with the building energy modeling software EnergyPlus® and OpenStudio® to generate a cost-effective training data set for developing AFDD algorithms. Part I (this paper) presents a library of fault models, including detailed descriptions of each fault model structure and their implementation with EnergyPlus. This paper also discusses a case study of training data set generation, representing an actual building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Constraining the Twomey effect from satellite observations: issues and perspectives

Abstract. The Twomey effect describes the radiative forcing associated with a change in cloud albedo due to an increase in anthropogenic aerosol emissions. It is driven by the perturbation in cloud droplet number concentration (ΔNd, ant) in liquid-water clouds and is currently understood to exert a cooling effect on climate. The Twomey effect is the key driver in the effective radiative forcing due to aerosol–cloud interactions, but rapid adjustments also contribute. These adjustments are essentially the responses of cloud fraction and liquid water path to ΔNd, ant and thus scale approximately with it. While the fundamental physics of the influence of added aerosol particles on the droplet concentration (Nd) is well described by established theory at the particle scale (micrometres), how this relationship is expressed at the large-scale (hundreds of kilometres) perturbation, ΔNd, ant, remains uncertain. The discrepancy between process understanding at particle scale and insufficient quantification at the climate-relevant large scale is caused by co-variability of aerosol particles and updraught velocity and by droplet sink processes. These operate at scales on the order of tens of metres at which only localised observations are available and at which no approach yet exists to quantify the anthropogenic perturbation. Different atmospheric models suggest diverse magnitudes of the Twomey effect even when applying the same anthropogenic aerosol emission perturbation. Thus, observational data are needed to quantify and constrain the Twomey effect. At the global scale, this means satellite data. There are four key uncertainties in determining ΔNd, ant, namely the quantification of (i) the cloud-active aerosol – the cloud condensation nuclei (CCN) concentrations at or above cloud base, (ii) Nd, (iii) the statistical approach for inferring the sensitivity of Nd to aerosol particles from the satellite data and (iv) uncertainty in the anthropogenic perturbation to CCN concentrations, which is not easily accessible from observational data. This review discusses deficiencies of current approaches for the different aspects of the problem and proposes several ways forward: in terms of CCN, retrievals of optical quantities such as aerosol optical depth suffer from a lack of vertical resolution, size and hygroscopicity information, non-direct relation to the concentration of aerosols, difficulty to quantify it within or below clouds, and the problem of insufficient sensitivity at low concentrations, in addition to retrieval errors. A future path forward can include utilising co-located polarimeter and lidar instruments, ideally including high-spectral-resolution lidar capability at two wavelengths to maximise vertically resolved size distribution information content. In terms of Nd, a key problem is the lack of operational retrievals of this quantity and the inaccuracy of the retrieval especially in broken-cloud regimes. As for the Nd-to-CCN sensitivity, key issues are the updraught distributions and the role of Nd sink processes, for which empirical assessments for specific cloud regimes are currently the best solutions. These considerations point to the conclusion that past studies using existing approaches have likely underestimated the true sensitivity and, thus, the radiative forcing due to the Twomey effect.

54 ENVIRONMENTAL SCIENCES↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

A high‐order discontinuous Galerkin approach for physics‐based thermospheric modeling

Abstract The accurate prediction of aerodynamic drag on satellites orbiting in the upper atmosphere is critical to the operational success of modern space technologies, such as satellite‐based communication or navigation systems, which have become increasingly popular in the last few years due to the deployment of constellations of satellites in low‐Earth orbit. As a result, physics‐based models of the ionosphere and thermosphere have emerged as a necessary tool for the prediction of atmospheric outputs under highly variable space weather conditions. This paper proposes a high‐fidelity approach for physics‐based space weather modeling based on the solution of the Navier–Stokes equations using a high‐order discontinuous Galerkin method, combined with a matrix‐free strategy suitable for high‐performance computing on GPU architectures. The approach consists of a thermospheric model that describes a chemically frozen neutral atmosphere in nonhydrostatic equilibrium driven by the external excitation of the Sun. A novel set of variables is considered to treat the low densities present in the upper atmosphere and to accommodate the wide range of scales present in the problem. At the same time, and unlike most existing approaches, radial and angular directions are treated in a nonsegregated approach. The study presents a set of numerical examples that demonstrate the accuracy of the approximation and validate the current approach against observational data along a satellite orbit, including estimates of established empirical and physics‐based models of the ionosphere‐thermosphere system. Finally, a one‐dimensional radial derivation of the physics‐based model is presented and utilized for conducting a parametric study of the main thermal quantities under various solar conditions.

Engineering↗

Large Synoptic Survey Telescope: From Science Drivers to Reference Design

In the history of astronomy, major advances in our understanding of the Universe have come from dramatic improvements in our ability to accurately measure astronomical quantities. Aided by rapid progress in information technology, current sky surveys are changing the way we view and study the Universe. Next-generation surveys will maintain this revolutionary progress. We focus here on the most ambitious survey currently planned in the visible band, the Large Synoptic Survey Telescope (LSST). LSST will have unique survey capability in the faint time domain. The LSST design is driven by four main science themes: constraining dark energy and dark matter, taking an inventory of the Solar System, exploring the transient optical sky, and mapping the Milky Way. It will be a large, wide-field ground-based system designed to obtain multiple images covering the sky that is visible from Cerro Pachon in Northern Chile. The current baseline design, with an 8.4 m (6.5 m effective) primary mirror, a 9.6 deg{sup 2} field of view, and a 3,200 Megapixel camera, will allow about 10,000 square degrees of sky to be covered using pairs of 15-second exposures in two photometric bands every three nights on average. The system is designed to yield high image quality, as well as superb astrometric and photometric accuracy. The survey area will include 30,000 deg{sup 2} with {delta} < +34.5{sup o}, and will be imaged multiple times in six bands, ugrizy, covering the wavelength range 320-1050 nm. About 90% of the observing time will be devoted to a deep-wide-fast survey mode which will observe a 20,000 deg{sup 2} region about 1000 times in the six bands during the anticipated 10 years of operation. These data will result in databases including 10 billion galaxies and a similar number of stars, and will serve the majority of science programs. The remaining 10% of the observing time will be allocated to special programs such as Very Deep and Very Fast time domain surveys. We describe how the LSST science drivers led to these choices of system parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanistic Modeling of TEG Dehydrator Emissions in Oil and Gas Industry

This work presents a mechanistic modeling approach for simulating methane emissions from triethylene glycol (TEG) dehydrators used in oil & gas (O&G) operations. The model was developed as a modular component of the Mechanistic Air Emissions Simulator (MAES) tool, incorporating species-specific absorption and emission dynamics through two-level, second-order polynomial regression (PR) models trained on ProMax simulation data: (1) species-level regression models that track the transfer rates of individual gas species within the dehydrator unit streams, and (2) outlet flow stream regression models that predict the fraction of inlet gas distributed among the outlet streams of the dehydrator unit. These behaviors were characterized over a range of glycol circulation ratios, wet gas pressures, and temperatures. The model was validated using root mean square error (RMSE) analysis. The species-level PR achieved low root mean square error (RMSE) values (<0.03) for light hydrocarbon species across all dehydrator components, ranging from 0.0009 for methane to 0.029 for normal pentane. Similarly, the outlet-level PR yielded RMSE values below 0.002 for the dry gas fraction, 0.001 for the flash tank fraction, and 0.002 for the still vent fraction, demonstrating strong agreement between predicted and reference ProMax values. When deployed at field facilities, the model significantly improved MAES-simulated dehydrator emissions, revealing that gas-assisted glycol pump emissions are the dominant contributors to both dehydrator-level and site-level methane emissions under uncontrolled conditions. Further analysis of the 154 dehydrator units reported by operators under the AMI 2024 project showed that 54 units (31%) used gas-driven glycol pumps, of which 6 units (11%) operated with uncontrolled flash tanks, and 22 units (40.7%) were identified as potentially oversized. Of the six dehydrator units with uncontrolled gas-assisted pumps, pump emissions accounted for 90.25% of total dehydrator emissions and 63.10% of total site-level emissions. These findings highlight substantial opportunities for emissions mitigation through equipment upgrades.

MAES↗

High Penetration of Photovoltaic Generation Study – Flagstaff Community Power (Final Technical Report, Results of Phases 2-5)

APS’s renewable energy portfolio, driven in part by Arizona’s Renewable Energy Standard (RES) currently includes more than 1100 MW of installed capacity, equating to roughly 3000 GWh of annual production. Overall renewable production is expected to grow to 6000 GWh by 2025. It is expected that distributed photovoltaics, driven primarily by lower cost, will contribute to much of this growth and that by 2025, distributed installations will account for half of all renewable production (3000GHW). As solar penetration increases, additional analysis may be required for routine utility processes to ensure continued safe and reliable operation of the electric distribution network. Such processes include residential or commercial interconnection requests and load shifting during normal feeder operations. Circuits with existing high solar penetration will also have to be studied and results will need to be evaluated for adherence to utility practices or strategy. Increased distributed PV penetration may offer benefits such as load offsetting, but it also has the potential to adversely impact distribution system operation. These effects may be exacerbated by the rapid variability of PV production. Detailed effects of these phenomena in distributed PV applications continue to be studied. Comprehensive, high-resolution electrical models of the distribution system were developed to analyze the impacts of PV on distribution circuit protection systems (including coordination and anti-islanding), predict voltage regulation and phase balance issues, and develop volt/VAr control schemes. Modeling methods were refined by validating against field measurements. To augment the field measurements, methods were developed to synthesize high resolution load and PV generation data to facilitate quasi-static time series simulations. The models were then extended to explore boundary conditions for PV hosting capability of the feeder and to simulate common utility practices such as feeder reconfiguration. The modeling and analysis methodology was implemented using open source tools and a process was developed to aid utility engineers in future interconnection requests. Methods to increase PV hosting capacity were also explored during the course of the study. A 700kVA grid-supportive inverter was deployed on the feeder and each grid support mode was demonstrated. Energy storage was explored through simulation and models were developed to calculate the optimum size and placement needed to increase PV hosting capacity. A tool was developed to aid planners in assigning relative costs and benefits to various strategies for increasing PV hosting capacity beyond current levels. Following the completion of the project, APS intends to use the tools and methods to improve the framework of future PV integration on its system. The tools and methods are also expected to aid other utilities to accelerate distributed PV deployment.

14 SOLAR ENERGY↗

Numerical Simulation of a Natural Convection–Driven Air-Cooled Reactor Cavity Cooling System Experiment

Ensuring the efficient removal of decay heat from the reactor vessel is essential for the safety of advanced reactor technologies. Several Generation-IV concepts incorporate variations in the reactor vessel cooling systems to achieve this objective. High-temperature gas-cooled reactors utilize a reactor cavity cooling system (RCCS), a passive ex-vessel system designed to operate without active components or external power during accident conditions. The RCCS removes decay heat primarily through radiative and convective heat transfer mechanisms. Here, this study presents a comprehensive validation of a computational fluid dynamics Reynolds-averaged Navier-Stokes model for the University of Wisconsin-Madison air-cooled RCCS facility. Validation was conducted for both high- and low-power natural convection cases under a uniform heating profile. Near-wall resolution was found to be critical for accurately modeling natural convection in the RCCS; employing an all-𝑦 + wall treatment resulted in wall temperature discrepancies exceeding 50 °⁢𝐶 compared to a wall-resolved mesh. Thermal-hydraulic behaviors under natural and forced convection conditions were compared within the heated cavity and RCCS. A turbulence model sensitivity analysis indicated that low-Reynolds number k-ɛ, k-ω shear stress transport (SST), and Reynolds stress transport models produce similar wall temperature predictions. A buoyancy modeling sensitivity study revealed that the Boussinesq approximation significantly underpredicted thermal-hydraulic behavior in the RCCS. Based on these findings, modeling recommendations are provided. The validated data set along with identified sensitivities refine the modeling of natural convection in the RCCS. The information produced by this study supports RCCS design, optimization, and safety evaluations, enabling the calibration and verification of reduced-order thermal-hydraulic models.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Decoupling of Arctic variability from the North Pacific in a warmer climate

The sea level pressure variability in the North Pacific modulates the climate of the Arctic and surrounding continents, substantially impacting ecosystems and indigenous communities. Our analysis based on data from the CESM2 Large Ensemble and different Model Intercomparison Project datasets reveals that the interannual variability of Arctic surface air temperature (SAT) gradually decouples from the contemporaneous atmospheric conditions over the North Pacific as external forcing increases in intensity in the future. Future projections show that the North Pacific-Arctic relationship during the fall season consistently weakens in magnitude until the end of this century, and in the 22nd and 23rd centuries, the relationship is negligible throughout the year. We show that under increased greenhouse gas emissions, the regional heat fluxes extensively control the Arctic temperature variability, and the strength of the projected North Pacific-Arctic relationship is strongly dependent on the Arctic sea ice extent. Our results suggest that under future warming, a strong coupling of Arctic SAT with the underlying ocean and a weakening of the meridional pressure gradient driven by an enhanced rate of sea ice retreat will weaken the interannual footprint of North Pacific variability on Arctic SAT. Therefore, we propose that the alarming rate of sea-ice decline over recent decades and projected in the near future could accelerate the rate of decoupling. Further, we suggest that mitigation strategies for the Arctic should focus on regional mechanisms operating on interannual and seasonal timescales.

54 ENVIRONMENTAL SCIENCES↗

Opportunities to Implement Solutions to Achieve Remedial Action Objectives in Consideration of Stakeholder Interests - 20365

A case study in the implementation of a soils excavation and removal project conducted at a Formerly Utilized Sites Remedial Action Program (FUSRAP) Maywood Superfund Site (FMSS) vicinity property; an active commercial business, in a densely populated area, with significant operational, technical and, logistical constraints that were expected to limit areas that could be remediated. The United States Army Corps of Engineers-led (USACE) team successfully navigated complex overlapping stakeholder interests to achieve a more efficient and complete removal of contaminated soils and debris while minimizing unnecessary excess costs to the Government. This paper centers on FUSRAP activities at the FMSS vicinity property located at 149-151 Maywood Avenue, Maywood, Bergen County, New Jersey. For most of its FUSRAP history, this ∼109,000 square meter (27-acre) property housed a now-demolished ∼26,000 square meter (6.5-acre) warehouse operated by Sears Logistics Services, a unit of the Sears Roebuck Company (Figure 2). Sears ended its property lease and vacated the warehouse in December 2016. Given that long history and for the purposes of this paper, the property will be referred to as the 'Sears property' or simply 'the property.' The Sears property is approximately 109,000 square meters (27-acres) and is currently zoned for commercial use. The property is bound to the north and northwest by 100 West Hunter Avenue (the Stepan Company), to the northeast by 205 Maywood Avenue, to the east by Maywood Avenue, to the south by 23 West Howcroft Road, and to the west by businesses on NJ Route 17 and the NJ Route 17 roadway. Until December 2016, the property housed a warehouse and distribution center operated by Sears Logistical Services. On-site structures were demolished by the property owner in 2017. The warehouse covered the north section of the property along the Stepan Company property line. A railroad spur from the adjacent property now known as the Maywood Interim Storage Site (MISS) ended at the northeast corner of the warehouse. Wetlands were located east of the warehouse; the rest of the property was covered with paved parking lots and grassed areas. During remediation at the property, opportunities frequently arose where the project team was able to coordinate effectively with stakeholders to sequence remediation activities to facilitate removal of otherwise inaccessible soils and identify opportunities for materials reuse when supported by residual radiological and chemical levels. Some specific opportunities include: - remediating individual truck loading dock bays to maintain tenant operations; - working along a busy highway and in a utility corridor containing a 30-inch high pressure gas main; - remediating Lodi Brook and associated wetlands requiring bypass pumping and other diversionary structures to maintain local community stormwater drainage; - protecting during remediation and supporting access to facilitate tenant/owner maintenance of critical fire protection and water supply system service lines buried in contaminated soils and necessary for safe warehouse operations; and - coordinating with stakeholders to ensure non-radiological contaminants of concern for the site (unaffiliated with FUSRAP) were addressed by the responsible party in a manner that maximized benefit to all parties while supporting an efficient overall site remediation program. Once the property was vacant and the warehouse structure and radiologically non-impacted above-grade structures were demolished, the project identified an opportunity to significantly reduce the volume of waste associated with the foundation of the former warehouse, a foundation suspected of being partially constructed in radiologically contaminated soils. The project developed and implemented supplemental radiological verification survey and sampling strategies based on radiological cross-contamination risk potential with process flow-charts and screening-level based decision points; a program that classified saw-cut sections of concrete based on observed residual surface radioactivity conditions using a combination of gamma sensitive sodium-iodide scans and beta sensitive Geiger-Muller direct measurements. The proposed approach was reviewed with stakeholders with feedback, including consideration of applicable State of New Jersey Site Remediation Program criteria and guidance before implementation. Once classified, additional sampling was performed at frequencies driven by screening. The sampling methods, stockpile sampling frequencies, criteria and, approach to data evaluation were developed in consideration of existing site cleanup standards, regional background ranges, State of New Jersey radiological remediation program guidance, and specific stakeholder input With the property remediation and survey efforts nearly completed, it is relevant to examine retrospectively the objectives, assumptions and limitations in the remedial design (i.e., what was planned) versus what was able to be accomplished through effective teaming. Benefits to other environmental remediation site programs include better understanding of how to work effectively with stakeholders to achieve win-win outcomes, and approaches to site remediation, waste minimization and materials reuse that were successful in their overall outcomes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of RELAP-7 for Forced Convective and Natural Circulation Reactor Flows

New reactor designs such as small modular reactors and newly proposed passive safety systems rely on natural circulation two-phase flow cooling of the reactor core under accident conditions. Without a pump to drive the flow, the circulation rate is a strong function of void fraction. Under these conditions where the flow rate, pressure drop, and heat transfer are all closely coupled through the mixture density, the accurate prediction of void fraction is pivotal. Furthermore, while these passive systems boast a more reliable cooling option, the sensitivity of the system to two-phase flow instabilities is more likely than in forced convective cooling and can result in dangerous density wave or flow excursion conditions. Improvement of one-dimensional system codes and further development of three-dimensional code capability are all important efforts in addressing these issues. The proposed work is a critical step towards providing confidence through validation of the capability of thermal-hydraulic tools to meet the emerging challenges in reactor simulation. Historically, system analysis codes develop a stiffness over time due to fine-tuning of adjustable code parameters that result in a reluctance or inability to adopt improved models. Therefore, a rigorous effort should be invested in preparation for RELAP-7 to identify required modeling improvements of constitutive relations and validation of the code applicability to the wide range of possible reactor flow conditions. Part of this validation involves the uncertainty quantification which is a critical step in the Code Scaling, Applicability, and Uncertainty (CSAU) methodology and Best-Estimate Plus Uncertainty (BEPU) licensing method. BEPU allows recovery of safety margins and potentially optimizing plant performance, resulting in economic benefit for the reactor operators. Beginning with the collection of past experimental data covering prototypic LWR conditions, this document reviews three critical datasets available for the validation of system codes. The experimental methods, procedures, facilities, instrumentation, and supplementary information are consolidated to aid the validation efforts of this work and future projects. These three datasets (824 conditions) are chosen due to their wide acceptance and demonstrated application for code validation. Two experimental datasets from the Nuclear Power Engineering Corporation (NUPEC) span prototypic conditions of Boiling Water Reactors (BWR) and Pressurized Water Reactors (PWR). These datasets are labeled as the BFBT (BWR Full-size Fine-mesh Bundle Test) and the PSBT (PWR Subchannel and Bundle Test) datasets respectively. The third dataset is taken in an internally heated annulus that is scaled based on a BWR subassembly and includes two-phase flows important to post-blowdown analysis. Together, the datasets consider the full range of pressure and mass flux expected in LWR forced convective flows from steady-state to long term cooling conditions. Recognizing the deficiency of available data under low-pressure, low-flow, a new natural circulation dataset consisting of 107 conditions is obtained. With system pressures ranging between 145 and 950 kPa, natural circulation is driven by a heat flux up to 275 kW/m2 in a 3 m long heated region of the annulus test section which is followed by a 2 m long unheated region before entering a condenser. Stable natural circulation flow rates in this facility were measured to be between 182 and 590 kg/m2-s. Pressure and temperature are measured at ten locations in the facility. In addition, measurements of void fraction, interfacial area concentration, and gas velocity are obtained at five axial locations in the annulus test section. The RELAP5-3D code demonstrates good accuracy for void fraction predictions in BFBT and PSBT benchmarks, but shows relatively large discrepancy in the annulus experiments at lower pressures. In two-phase natural circulation, large oscillations are observed in many system parameters during the simulation of 19 experiment cases which were conducted at low pressures, and the model shows good predictive performance with the remaining 88 experiment cases. However, some discrepancies in void fraction and temperature predictions are found which may require improved constitutive modeling under these low-pressure, low-flow condition. The quantified uncertainty in void fraction predictions in three forced convection benchmarks due to uncertainties in boundary conditions and geometries are relatively small, except for a few cases in the annulus experiment. The output uncertainty of the natural circulation model is quantified by considering the measurement error in boundary conditions, and it is shown that the output uncertainty ranges are relatively small for the range of conditions considered. Through this work, a clear pathway is provided for validation of RELAP7 once the code is available.

42 ENGINEERING↗