Search NASA⌕ Search

SEARCH · Search NASA

Results for “deformable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Generalized symmetry constraints on deformed 4D SCFTs

We explore the consequence of generalized symmetries in four-dimensional N = 1 superconformal field theories. First, we classify all possible supersymmetric gauge theories with a simple gauge group that have a nontrivial one-form symmetry and flows to a superconformal field theory. Upon identifying unbroken discrete zero-form symmetries from the Adler-Bell-Jackiw (ABJ) anomaly, we find that many of these theories have mixed zero-form or one-form ’t Hooft anomalies. Then we classify the relevant deformations of these SCFTs that preserve the anomaly. From this mixed anomaly together with the anomalies of the discrete zero-form symmetries, we find obstructions for the relevant deformations of these SCFTs to flow to a trivially gapped phase. We also study non-Lagrangian SCFTs formed by gauging copies of Argyres-Douglas theories and constrain their deformations. In particular, we explore a new duality between the diagonal gauging of two D 3 ( S U ( N ) ) theories and S U ( N ) gauge theory with two adjoints. We also repeat our analysis for a host of nonsupersymmetric gauge theories having nontrivial one-form symmetry including examples that appear to flow to Bank-Zaks type CFTs. Published by the American Physical Society 2025

Kang, Monica Jinwoo (ORCID:0000000204542064)↗

Emergent noncommutative gravity from a consistent deformation of gauge theory

Starting from a standard noncommutative gauge theory and using the Seiberg-Witten map, we propose a new version of a noncommutative gravity. We use consistent deformation theory starting from a free gauge action and gauging a killing symmetry of the background metric to construct a deformation of the gauge theory that we can relate with gravity. The result of this consistent deformation of the gauge theory is nonpolynomial in A{sub {mu}.} From here we can construct a version of noncommutative gravity that is simpler than previous attempts. Our proposal is consistent and is not plagued with the problems of other approaches like twist symmetries or gauging other groups.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Anatomy of a deformed symmetry: Field quantization on curved momentum space

In certain scenarios of deformed relativistic symmetries relevant for noncommutative field theories particles exhibit a momentum space described by a non-Abelian group manifold. Starting with a formulation of phase space for such particles which allows for a generalization to include group-valued momenta we discuss quantization of the corresponding field theory. Focusing on the particular case of {kappa}-deformed phase space we construct the one-particle Hilbert space and show how curvature in momentum space leads to an ambiguity in the quantization procedure reminiscent of the ambiguities one finds when quantizing fields in curved space-times. The tools gathered in the discussion on quantization allow for a clear definition of the basic deformed field mode operators and two-point function for {kappa}-quantum fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deformations, relaxation, and broken symmetries in liquids, solids, and glasses: A unified topological field theory

Here, we combine hydrodynamic and field theoretic methods to develop a general theory of phonons as Goldstone bosons in crystals, glasses, and liquids based on nonaffine displacements and the consequent Goldstone phase relaxation. We relate the conservation, or lack thereof, of specific higher-form currents with properties of the underlying deformation field—nonaffinity—which dictates how molecules move under an applied stress or deformation. In particular, the single-valuedness of the deformation field is associated with conservation of higher-form charges that count the number of topological defects. Our formalism predicts, from first principles, the presence of propagating shear waves above a critical wave vector in liquids, thus giving a formal derivation of the phenomenon in terms of fundamental symmetries. The same picture provides also a theoretical explanation of the corresponding “positive sound dispersion” phenomenon for longitudinal sound. Importantly, accordingly to our theory, the main collective relaxation timescale of a liquid or a glass (known as the α relaxation for the latter) is given by the phase relaxation time, which is not necessarily related to the Maxwell time. Finally, we build a nonequilibrium effective action using the in-in formalism defined on the Schwinger-Keldysh contour, that further supports the emerging picture. In summary, our work suggests that the fundamental difference between solids, fluids, and glasses has to be identified with the associated generalized higher-form global symmetries and their topological structure, and that the Burgers vector for the displacement fields serves as a suitable topological order parameter distinguishing the solid (ordered) phase and the amorphous ones (fluids, glasses).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shape Coexistence Near Neutron Number N=20: First Identification of the E0 Decay from the Deformed First Excited J{sup p}i=0{sup +} State in {sup 30}Mg

The 1789 keV state in {sup 30}Mg was identified as the first excited 0{sup +} state via its electric monopole (E0) transition to the ground state. The measured small value of rho{sup 2}(E0,0{sub 2}{sup +}->0{sub 1}{sup +})=(26.2+-7.5)x10{sup -3} implies within a two-level model a small mixing of competing configurations with largely different intrinsic quadrupole deformation near the neutron shell closure at N=20. Axially symmetric configuration mixing calculations identify the ground state of {sup 30}Mg to be based on neutron configurations below the N=20 shell closure, while the excited 0{sup +} state mainly consists of two neutrons excited into the nu 1f{sub 7/2} orbital. The experimental result represents the first case where an E0 back decay from a strongly deformed second to the normal deformed first nuclear potential minimum well has been unambiguously identified, thus directly proving shape coexistence at the borderline of the much-debated 'island of inversion.'

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence for Rigid Triaxial Deformation in Ge 76 from a Model-Independent Analysis

An extensive, model-independent analysis of the nature of triaxial deformation in 76 Ge, a candidate for neutrinoless double-beta (0νββ) decay, was carried out following multistep Coulomb excitation. Shape parameters deduced on the basis of a rotational-invariant sum-rule analysis provided considerable insight into the underlying collectivity of the ground-state and γ bands. Both sequences were determined to be characterized by the same β and γ deformation parameter values. In addition, compelling evidence for low-spin, rigid triaxial deformation in 76 Ge was obtained for the first time from the analysis of the statistical fluctuations of the quadrupole asymmetry deduced from the measured E 2 matrix elements. Furthermore, these newly determined shape parameters are important input and constraints for calculations aimed at providing, with suitable accuracy, the nuclear matrix elements relevant to 0νββ.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of Nuclear Deformation on Relativistic Heavy-Ion Collisions: Assessing Consistency in Nuclear Physics across Energy Scales

In the hydrodynamic framework of heavy-ion collisions, elliptic flow v 2 is sensitive to the quadrupole deformation β of the colliding ions. This enables one to test whether the established knowledge on the low-energy structure of nuclei is consistent with collider data from high-energy experiments. We derive a formula based on generic scaling laws of hydrodynamics to relate the difference in v 2 measured between collision systems that are close in size to the value of β of the respective species. We validate our formula in simulations of 238 U + 238 U and 197 Au + 197 Au collisions at top Relativistic Heavy Ion Collider (RHIC) energy, and subsequently apply it to experimental data. Using the deformation of 238 U from low-energy experiments, we find that RHIC v 2 data implies 0.16 ≲ | β | ≲ 0.20 for 197 Au nuclei, i.e., significantly more deformed than reported in the literature, posing an interesting issue in nuclear phenomenology.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of Photovoltaic Module Deformation Dynamics During Hail Impact Using Digital Image Correlation

Stereo high-speed video of photovoltaic modules undergoing laboratory hail tests was processed using digital image correlation to determine module surface deformation during and immediately following impact. The purpose of this work was to demonstrate a methodology for characterizing module impact response differences as a function of construction and incident hail parameters. Video capture and digital image analysis were able to capture out-of-plane module deformation to a resolution of ±0.1 mm at 11 kHz on an in-plane grid of 10 × 10 mm over the area of a 1 × 2 m commercial photovoltaic module. With lighting and optical adjustments, the technique was adaptable to arbitrary module designs, including size, backsheet color, and cell interconnection. Furthermore, impacts were observed to produce an initially localized dimple in the glass surface, with peak deflection proportional to the square root of incident energy. Subsequent deformation propagation and dissipation were also captured, along with behavior for instances when the module glass fractured. Natural frequencies of the module were identifiable by analyzing module oscillations postimpact. Limitations of the measurement technique were that the impacting ice ball obscured the data field immediately surrounding the point of contact, and both ice and glass fracture events occurred within 100 μs, which was not resolvable at the chosen frame rate. Increasing the frame rate and visualizing the back surface of the impact could be applied to avoid these issues. Applications for these data include validating computational models for hail impacts, identifying the natural frequencies of a module, and identifying damage initiation mechanisms.

14 SOLAR ENERGY↗

Electro-hydraulic forming of advanced high-strength steels: Deformation and microstructural characterization

This conference manuscript describes mechanical and microstructural characterization of steel sheets that were deformed via the electro-hydraulic forming technique. The manuscripts shows the importance of the experimental technique developed at PNNL in the sense that the deformation history information enabled by this technique is not obtainable through existing conventional approaches. Additionally, strain-rate effects on texture development during sheet-forming at high-rates are described. Thus, we have demonstrated that it is now possible to correlate deformation history with microstructural development during high-rate forming, a capability that is unique to PNNL.

Rohatgi, Aashish↗

Comparing the accuracy of four-dimensional photon dose calculations with three-dimensional calculations using moving and deforming phantoms

Purpose: Four-dimensional (4D) dose calculation algorithms, which explicitly incorporate respiratory motion in the calculation of doses, have the potential to improve the accuracy of dose calculations in thoracic treatment planning; however, they generally require greater computing power and resources than currently used for three-dimensional (3D) dose calculations. The purpose of this work was to quantify the increase in accuracy of 4D dose calculations versus 3D dose calculations. Methods: The accuracy of each dose calculation algorithm was assessed using measurements made with two phantoms. Specifically, the authors used a rigid moving anthropomorphic thoracic phantom and an anthropomorphic thoracic phantom with a deformable lung insert. To incorporate a clinically relevant range of scenarios, they programed the phantoms to move and deform with two motion patterns: A sinusoidal motion pattern and an irregular motion pattern that was extracted from an actual patient's breathing profile. For each combination of phantom and motion pattern, three plans were created: A single-beam plan, a multiple-beam plan, and an intensity-modulated radiation therapy plan. Doses were calculated using 4D dose calculation methods as well as conventional 3D dose calculation methods. The rigid moving and deforming phantoms were irradiated according to the three treatment plans and doses were measured using thermoluminescent dosimeters (TLDs) and radiochromic film. The accuracy of each dose calculation algorithm was assessed using measured-to-calculated TLD doses and a {gamma} analysis. Results: No significant differences were observed between the measured-to-calculated TLD ratios among 4D and 3D dose calculations. The {gamma} results revealed that 4D dose calculations had significantly greater percentage of pixels passing the 5%/3 mm criteria than 3D dose calculations. Conclusions: These results indicate no significant differences in the accuracy between the 4D and the 3D dose calculation methods inside the gross tumor volume. On the other hand, the film results demonstrated that the 4D dose calculations provided greater accuracy than 3D dose calculations in heterogeneous dose regions. The increase in accuracy of the 4D dose calculations was evident throughout the planning target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT

Purpose: High-speed nonrigid registration between the planning CT and the treatment CBCT data is critical for real time image guided radiotherapy (IGRT) to improve the dose distribution and to reduce the toxicity to adjacent organs. The authors propose a new fully automatic 3D registration framework that integrates object-based global and seed constraints with the grayscale-based ''demons'' algorithm. Methods: Clinical objects were segmented on the planning CT images and were utilized as meshless deformable models during the nonrigid registration process. The meshless models reinforced a global constraint in addition to the grayscale difference between CT and CBCT in order to maintain the shape and the volume of geometrically complex 3D objects during the registration. To expedite the registration process, the framework was stratified into hierarchies, and the authors used a frequency domain formulation to diffuse the displacement between the reference and the target in each hierarchy. Also during the registration of pelvis images, they replaced the air region inside the rectum with estimated pixel values from the surrounding rectal wall and introduced an additional seed constraint to robustly track and match the seeds implanted into the prostate. The proposed registration framework and algorithm were evaluated on 15 real prostate cancer patients. For each patient, prostate gland, seminal vesicle, bladder, and rectum were first segmented by a radiation oncologist on planning CT images for radiotherapy planning purpose. The same radiation oncologist also manually delineated the tumor volumes and critical anatomical structures in the corresponding CBCT images acquired at treatment. These delineated structures on the CBCT were only used as the ground truth for the quantitative validation, while structures on the planning CT were used both as the input to the registration method and the ground truth in validation. By registering the planning CT to the CBCT, a displacement map was generated. Segmented volumes in the CT images deformed using the displacement field were compared against the manual segmentations in the CBCT images to quantitatively measure the convergence of the shape and the volume. Other image features were also used to evaluate the overall performance of the registration. Results: The algorithm was able to complete the segmentation and registration process within 1 min, and the superimposed clinical objects achieved a volumetric similarity measure of over 90% between the reference and the registered data. Validation results also showed that the proposed registration could accurately trace the deformation inside the target volume with average errors of less than 1 mm. The method had a solid performance in registering the simulated images with up to 20 Hounsfield unit white noise added. Also, the side by side comparison with the original demons algorithm demonstrated its improved registration performance over the local pixel-based registration approaches. Conclusions: Given the strength and efficiency of the algorithm, the proposed method has significant clinical potential to accelerate and to improve the CBCT delineation and targets tracking in online IGRT applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstruction of 3D lung models from 2D planning data sets for Hodgkin's lymphoma patients using combined deformable image registration and navigator channels

Purpose: Late complications (cardiac toxicities, secondary lung, and breast cancer) remain a significant concern in the radiation treatment of Hodgkin's lymphoma (HL). To address this issue, predictive dose-risk models could potentially be used to estimate radiotherapy-related late toxicities. This study investigates the use of deformable image registration (DIR) and navigator channels (NCs) to reconstruct 3D lung models from 2D radiographic planning images, in order to retrospectively calculate the treatment dose exposure to HL patients treated with 2D planning, which are now experiencing late effects. Methods: Three-dimensional planning CT images of 52 current HL patients were acquired. 12 image sets were used to construct a male and a female population lung model. 23 ''Reference'' images were used to generate lung deformation adaptation templates, constructed by deforming the population model into each patient-specific lung geometry using a biomechanical-based DIR algorithm, MORFEUS. 17 ''Test'' patients were used to test the accuracy of the reconstruction technique by adapting existing templates using 2D digitally reconstructed radiographs. The adaptation process included three steps. First, a Reference patient was matched to a Test patient by thorax measurements. Second, four NCs (small regions of interest) were placed on the lung boundary to calculate 1D differences in lung edges. Third, the Reference lung model was adapted to the Test patient's lung using the 1D edge differences. The Reference-adapted Test model was then compared to the 3D lung contours of the actual Test patient by computing their percentage volume overlap (POL) and Dice coefficient. Results: The average percentage overlapping volumes and Dice coefficient expressed as a percentage between the adapted and actual Test models were found to be 89.2{+-}3.9% (Right lung=88.8%; Left lung=89.6%) and 89.3{+-}2.7% (Right=88.5%; Left=90.2%), respectively. Paired T-tests demonstrated that the volumetric reconstruction method made a statistically significant improvement to the population lung model shape (p<0.05). The error in the results were also comparable to the volume overlap difference observed between inhale and exhale lung volumes during free-breathing respiratory motion (POL:p=0.43; Dice:p=0.20), which implies that the accuracies of the reconstruction method are within breathing constraints and would not be the confining factor in estimating normal tissue dose exposure. Conclusions: The result findings show that the DIR-NC technique can achieve a high degree of reconstruction accuracy, and could be useful in approximating 3D dosimetric representations of historical 2D treatment. In turn, this could provide a better understanding of the biophysical relationship between dose-volume exposure and late term radiotherapy effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-18A-01: Tumor Motion Tracking with a Regional Deformable Registration Model for Four Dimensional Radiation Treatment of Lung Cancer

Purpose: To develop a tumor motion model from four-dimensional computed tomography (4DCT) of thoracic patients and demonstrate its impact on 4D radiation therapy simulation. Methods: A regional deformable image registration algorithm was introduced to extract tumor motion out of patient's breathing cycle. The gross target volume (GTV) was manually delineated on a selected phase of 4DCT and a subregion with 10mm margin supplemented to the GTV was created on the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA). Together with 4DCT the structures were exported into an inhouse research platform. A free form B-Spline deformable registration was carried out to map the subregion to other respiratory phases. The displacement vector fields were employed to propagate GTV contours with which the center of mass (CoM) of the GTV was computed for each breathing phase of 4DCT. The resultant GTV motion and its volumetric shape are utilized to facilitate 4D treatment planning. Five lung cancer patients undergoing stereotactic body radiation therapy were enrolled and their 4DCT sets were included in the study. Results: Application of the algorithm to five thoracic patients indicates that clinically satisfactory outcomes were achievable with a spatial accuracy better than 2mm for GTV contour propagation between adjacent phases, and 3mm between opposite phases. The GTV CoM was found to be in the range of 2.0mm through 2.5cm, depending upon the tumor location. Compared to the traditional whole image based registration, the computation of the regional model was found to be an order of magnitude more efficient. Conclusion: A regional deformable registration model was implemented to extract tumor motion. It will have widespread application in 4D radiation treatment planning in the future to maximally utilize the available spatial-tempo information.

60 APPLIED LIFE SCIENCES↗

SU-E-J-148: Evaluating Tumor Response with a Commercially Available Deformable Registration System

Purpose: The purpose of this study is to present a method for evaluating the response to treatment using a commercially available deformable image registration software package (Velocity Medical Systems) and repeat PET/CT imaging. This technique can be used to identify volumes that are risk for tumor recurrence. Methods: Response to treatment was evaluated using PET/CT images acquired prior-to and post-treatment for radiation therapy patients treated with concurrent chemotherapy. Velocity (Version 3.0.1) was used to deform the initial PET/CT to the post treatment PET/CT. The post-treatment PET images were then subtracted from the pre-treatment PET images. The resulting re-sampled image is a three-dimensional SUV difference map that shows pixels with increasing SUV values. SUV values increases greater than 2.5 in the post treatment images were identified for additional follow-up. Results: A total of 5 Lung patients were analyzed as part of this study. One lung patient in the cohort had an SUV increase of +3.28 that was identified using the SUV difference map. This volume of increased uptake was located outside the treatment field and adjacent to the 35 Gy isodose line. The remaining four patients all had SUV decreases inside the planning target volume, and no unexpected areas of increase outside the irradiated volumes. All five patients were analyzed using standard tools inside the Velocity application. Conclusion: The response to treatment can easily be measured using serial PET/CT images and a commercially available deformable image registration. This provides both the radiation oncologists and medical oncologists with a quantitative assessment of their treatment to use in patient follow-up.

60 APPLIED LIFE SCIENCES↗

SU-E-J-226: Propagation of Pancreas Target Contours On Respiratory Correlated CT Images Using Deformable Image Registration

Purpose: Respiratory Correlated CT (RCCT) scans to assess intra-fraction motion among pancreatic cancer patients undergoing radiotherapy allow for dose sparing of normal tissues, in particular for the duodenum. Contour propagation of the gross tumor volume (GTV) from one reference respiratory phase to 9 other phases is time consuming. Deformable image registration (DIR) has been successfully used for high contrast disease sites but lower contrast for pancreatic tumors may compromise accuracy. This study evaluates the accuracy of Fast Free Form (FFF) registration-based contour propagation of the GTV on RCCT scans of pancreas cancer patients. Methods: Twenty-four pancreatic cancer patients were retrospectively studied; 20 had tumors in the pancreatic head/neck, 4 in the body/tail. Patients were simulated with RCCT and images were sorted into 10 respiratory phases. A radiation oncologist manually delineated the GTV for 5 phases (0%, 30%, 50%, 70% and 90%). The FFF algorithm was used to map deformations between the EE (50%) phase and each of the other 4 phases. The resultant deformation fields served to propagate GTV contours from EE to the other phases. The Dice Similarity Coefficient (DSC), which measures agreement between the DIR-propagated and manually-delineated GTVs, was used to quantitatively examine DIR accuracy. Results: Average DSC over all scans and patients is 0.82 and standard deviation is 0.09 (DSC range 0.97–0.57). For GTV volumes above and below the median volume of 20.2 cc, a Wilcoxon rank-sum test shows significantly different DSC (p=0.0000002). For the GTVs above the median volume, average +/− SD is 0.85 +/− 0.07; and for the GTVs below, the average +/− SD is 0.75 +/−0.08. Conclusion: For pancreatic tumors, the FFF DIR algorithm accurately propagated the GTV between the images in different phases of RCCT, with improved performance for larger tumors.

60 APPLIED LIFE SCIENCES↗

SU-E-J-254: Utility of Pinnacle Dynamic Planning Module Utilizing Deformable Image Registration in Adaptive Radiotherapy

Purpose For certain highly conformal treatment techniques, changes in patient anatomy due to weight loss and/or tumor shrinkage can result in significant changes in dose distribution. Recently, the Pinnacle treatment planning system added a Dynamic Planning module utilizing Deformable Image Registration (DIR). The objective of this study was to evaluate the effectiveness of this software in adapting to altered anatomy and adjusting treatment plans to account for it. Methods We simulated significant tumor response by changing patient thickness and altered chin positions using a commercially-available head and neck (H and N) phantom. In addition, we studied 23 CT image sets of fifteen (15) patients with H and N tumors and eight (8) patients with prostate cancer. In each case, we applied deformable image registration through Dynamic Planning module of our Pinnacle Treatment Planning System. The dose distribution of the original CT image set was compared to the newly computed dose without altering any treatment parameter. Result was a dose if we did not adjust the plan to reflect anatomical changes. Results For the H and N phantom, a tumor response of up to 3.5 cm was correctly deformed by the Pinnacle Dynamic module. Recomputed isodose contours on new anatomies were within 1 mm of the expected distribution. The Pinnacle system configuration allowed dose computations resulting from original plans on new anatomies without leaving the planning system. Original and new doses were available side-by-side with both CT image sets. Based on DIR, about 75% of H and N patients (11/15) required a re-plan using new anatomy. Among prostate patients, the DIR predicted near-correct bladder volume in 62% of the patients (5/8). Conclusions The Dynamic Planning module of the Pinnacle system proved to be an accurate and useful tool in our ability to adapt to changes in patient anatomy during a course of radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-J-263: Dosimetric Analysis On Breast Brachytherapy Based On Deformable Image Registration

Purpose: To quantitatively compare and evaluate the dosimetry difference between breast brachytherapy protocols with different fractionation using deformable image registration. Methods: The accumulative dose distribution for multiple breast brachytherapy patients using four different applicators: Contura, Mammosite, Savi, and interstitial catheters, under two treatment protocols: 340cGy by 10 fractions in 5 days and 825cGy by 3 fractions in 2days has been reconstructed using a two stage deformable image registration approach. For all patients, daily CT was acquired with the same slice thickness (2.5mm). In the first stage, the daily CT images were rigidly registered to the initial planning CT using the registration module in Eclipse (Varian) to align the applicators. In the second stage, the tissues surrounding the applicator in the rigidly registered daily CT image were non-rigidly registered to the initial CT using a combination of image force and the local constraint that enforce zero normal motion on the surface of the applicator, using a software developed in house. We calculated the dose distribution in the daily CTs and deformed them using the final registration to convert into the image domain of the initial planning CT. The accumulative dose distributions were evaluated by dosimetry parameters including D90, V150 and V200, as well as DVH. Results: Dose reconstruction results showed that the two day treatment has a significant dosimetry improvement over the five day protocols. An average daily drop of D90 at 1.3% of the prescription dose has been observed on multiple brachytherapy patients. There is no significant difference on V150 and V200 between those two protocols. Conclusion: Brachytherapy with higher fractional dose and less fractions has an improved performance on being conformal to the dose distribution in the initial plan. Elongated brachytherapy treatments need to consider the dose uncertainty caused by the temporal changes of the soft tissue.

60 APPLIED LIFE SCIENCES↗

SU-E-J-266: A Pitfall of a Deformable Image Registration in Lung Cancer

Purpose: For four-dimensional (4D) planning and adaptive radiotherapy, deformable image registration (DIR) is needed and the accuracy is essential. We evaluated the accuracy of one free-downloadable DIR software library package (NiftyReg) and one commercial DIR software (MIM) in lung SBRT cancer patients. Methods: A rigid and non-rigid registrations were implemented to our in-house software. The non-rigid registration algorithm of the NiftyReg and MIM was based on the free-form deformation. The accuracy of the two software was evaluated when contoured structures to peak-inhale and peak-exhale 4DCT image data sets were measured using the dice similarity coefficient (DSC). The evaluation was performed in 20 lung SBRT patients. Results: In our visual evaluation, the eighteen cases show good agreement between the deformed structures for the peak-inhale phase and the peak-exhale phase structures (more than 0.8 DSC value). In the evaluation of the DSC in-house software, averaged DSC values of GTV and lung, heart, spinal cord, stomach and body were 0.862 and 0.979, 0.932, 0.974, 0.860, 0.998, respectively. As the Resultof the registration using the MIM program in the two cases which had less than 0.7 DSC value when analyzed using the in-house software, the DSC value were improved to 0.8. The CT images in a case with low DSC value shows the tumor was surrounded by the structure with the similar CT values, which were the chest wall or the diaphragm. Conclusion: Not only a free-downloadable DIR software but also a commercial software may provide unexpected results and there is a possibility that the results would make us misjudge the treatment planning. Therefore, we recommend that a commissioning test of any DIR software should be performed before clinical use and we should understand the characteristics of the software.

60 APPLIED LIFE SCIENCES↗