Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

SU-F-T-431: Dosimetric Validation of Acuros XB Algorithm for Photon Dose Calculation in Water

Purpose: To validate the Acuros XB algorithm implemented in Eclipse Treatment planning system version 11 (Varian Medical System, Inc., Palo Alto, CA, USA) for photon dose calculation. Methods: Acuros XB is a Linear Boltzmann transport equation (LBTE) solver that solves LBTE equation explicitly and gives result equivalent to Monte Carlo. 6MV photon beam from Varian Clinac-iX (2300CD) was used for dosimetric validation of Acuros XB. Percentage depth dose (PDD) and profiles (at dmax, 5, 10, 20 and 30 cm) measurements were performed in water for field size ranging from 2×2,4×4, 6×6, 10×10, 20×20, 30×30 and 40×40 cm{sup 2}. Acuros XB results were compared against measurements and anisotropic analytical algorithm (AAA) algorithm. Results: Acuros XB result shows good agreement with measurements, and were comparable to AAA algorithm. Result for PDD and profiles shows less than one percent difference from measurements, and from calculated PDD and profiles by AAA algorithm for all field size. TPS calculated Gamma error histogram values, average gamma errors in PDD curves before dmax and after dmax were 0.28, 0.15 for Acuros XB and 0.24, 0.17 for AAA respectively, average gamma error in profile curves in central region, penumbra region and outside field region were 0.17, 0.21, 0.42 for Acuros XB and 0.10, 0.22, 0.35 for AAA respectively. Conclusion: The dosimetric validation of Acuros XB algorithms in water medium was satisfactory. Acuros XB algorithm has potential to perform photon dose calculation with high accuracy, which is more desirable for modern radiotherapy environment.

60 APPLIED LIFE SCIENCES↗

Modeling Dust in East Asia by CESM and Sources of Biases

East Asian dust has a significant impact on regional and global climate. In this study, we evaluate the spatial distributions and temporal variations of dust extinction profiles and dust optical depth (DOD) over East Asia simulated from the Community Earth System Model (CESM) with satellite retrievals from Luo, Wang, Ferrare, et al., Luo, Wang, Zhang, et al. (L15), Yu et al. (Y15), and Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) level 3 products. Both L15 and Y15 are based on CALIPSO products but use different algorithms to separate dust from nondust aerosols. We find high model biases of dust extinction in the upper troposphere over the Taklamakan desert, Gobi desert, and Tibetan Plateau, especially in the summer (June-July-August). CESM with dust emission scheme of Kok, Mahowald, et al. and Kok, Albani, et al. has the best agreement with dust extinction profiles and DOD from L15 in the Taklamakan desert and Tibetan Plateau. CESM with the default dust emission scheme of Zender, Bian, and Newman underpredicts DOD in the Tibetan Plateau compared with observations from L15 due to the underestimation of local dust emission. Large uncertainties exist in observations from L15, Y15, and CALIPSO level 3 products and have significant impacts on the model evaluation of dust spatial distributions. We also assess dust surface concentrations and 10-m wind speed with meteorological records from weather stations in the Taklamakan and Gobi deserts during dust events. We note CESM underestimates dust surface concentrations at most weather stations due to the inability of CESM to capture strong surface wind events.

58 GEOSCIENCES↗

SU-E-T-813: What Is the “real” Field-Size in Photon Dosimetry?

Purpose: The definition of field sizes in photon dosimetry and the measurement of profiles are non-trivial. Current definitions are nominal, geometric, dosimetric (actual) or equivalent field size. In reality most detectors are not water equivalent since they contain air or high density materials. These materials can blur profiles, particularly in small fields. If necessary, detector and field size-specific volume dependent effects need to be considered. Methods: A TrueBeam-linac (Varian Medical Systems) was used. All measurements were performed within a water phantom (MP3, PTW-Freiburg), with filter (WFF) and without filter (FFF), using ionization chambers, shielded and unshielded diodes and diamond detectors. The position of the jaws was verified according to our QA-system. Field size profiles were taken at a defined depth (SSD =90 cm, SCD=100 cm). The penumbra of the profiles measured with the various detectors was compared to determine the dosimetric field size. For the evaluation of the field sizes the inclination points were also calculated. Results: The field size, both for the WFF and the FFF-mode, coincided within 1 mm of the nominal field size. Due to the fact that the jaws were adjusted properly, the dosimetric field size coincides with the geometric field size. Exceptions are very small fields, where the dosimetric field size, defined by the inclination points, becomes broader than the geometric field size. Conclusion: Profiles, particularly of small fields, have to be measured very carefully using a suitable detector. For this purpose, a detector with a negligible volume correction factor should be used. The dosimetric field size can be found by evaluating the inclination points for both WFF and FFF beams. For dosimetric purposes it is necessary to find the dosimetric size. Alternatively, if the measurements are basic data for a TPS, both, the geometric and the dosimetric sizes should be recorded.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of Nitrate, Nitrite, Ammonia, and Tritium in D0220 Cores

This report describes characterization of nitrogen species (nitrate, nitrite, ammonia) in aqueous and solid phases in cores taken in borehole D0220 (well 299-E25-245) under crib 216-A-37-1 at the Hanford Site in 2022 to evaluate (a) the types of nitrogen species currently in the vadose zone and (b) the migration of nitrogen species in the vadose zone. Ammonia and tritium from PUREX decladding condensate were sporadically discharged to the crib from 1977 to 1989. During discharge operations, the estimated travel time through the vadose zone to groundwater was 2.5 to 9 months. By 2003, a characterization borehole (C4106) showed residual pore water with elevated tritium and nitrate in the first 100 ft of the vadose zone, which is likely from the crib. However, there was significantly more nitrate present at the shallowest depth (15 to 22 ft), which may indicate a different source for nitrate, such as adsorbed ammonia slowly being oxidized or nitrogen species precipitates slowly dissolving. In this study, more extensive nitrogen species characterization was done on D0220 cores (drilled in 2022) at 40- and 262-ft depths, which included (a) aqueous nitrate, nitrite, and tritium; (b) adsorbed ammonia; (c) nitrogen in carbonates (or other minerals dissolved in acidic acid); (d) nitrogen in iron oxides (or other minerals dissolved in oxalic acid); and (e) nitrogen in hard-to-extract minerals (minerals dissolved in nitric acid). High pore water nitrate (226 to 331 mg/L) at 40-ft depth measured in D0220 (2022) compared to 60 mg/L at 40-ft depth in C4106 (2003) may indicate nitrate is migrating deeper. Tritium concentrations (pore water 132,000 to 148,000 pCi/L) measured in D0220 at 40-ft depth in 2022 were considerably higher than in C4106 at 40-ft depth (160 pCi/L). Additional nitrogen species mass was present in adsorbed and precipitated phases in D0220 cores. Low adsorbed ammonia was measured at 40.1- and 261.7-ft depths. Low concentrations of carbonate associated nitrogen and iron oxide-associated nitrogen were present at 40.1 and 40.6 ft depths. Nitrogen species in solid phase extractions indicate nitrogen precipitates or aqueous nitrate or ammonia trapped in sediment microfractures that are coated by precipitates. Overall, the nitrogen species and tritium characterization at two depths in D0220 showed that additional nitrogen species were present in the vadose zone. In addition, elevated pore water nitrate in D0220 at 40 ft depth from 2022 may indicate vertical migration compared to C4106 nitrate profile from 2003. Analysis of additional depths in D0220 and spatial variability of the nitrate plume along the length of the crib (from surface electrical resistivity) would be extremely useful for this comparison.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Endothelium Preserving Microwave Treatment for Atherosclerosis

Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial laser and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount, about 20 C., within the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radial sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed, directable of focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and man be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.

Carl, James R.↗

Endothelium Preserving Microwave Treatment for Atherosclerois

Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof. Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial layer and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount about 20 C, with the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radical sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed, directable or focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and may be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.

Carl, James R.↗

Endothelium Preserving Microwave Treatment for Atherosclerosis

Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof. Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial layer and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount, about 20 C. within the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radial sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed directable or focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and may be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.

Carl, James R.↗

Endothelium Preserving Microwave Treatment for Atherosclerosis

Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof. Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial layer and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount, about 20 C. within the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radial sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed, directable or focussed heating preserves healthy sectors or the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed bean. A computer simulation predicts isothermic temperature profiles for the given conditions and may be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.

James R Carl↗

Characterization of macrosegregation in ESR IN-718

Aspects of macrosegregation theory, such as dendrite arm spacing, pool profile and mushy zone depth are beneficial to developing consumable melting process for Ion Nickel IN-718, Electro-Slag Refining, especially ESR. Aspects of microsegregation theory, such as correlation of dendrite arm spacing with heat transfer mechanisms and local solidification time, are used to minimize remnant dendritism in both ESR and Vacuum Arc Remelting VAR IN-718. Specifically, ESR IN-718 must be optimized by developing practices which maximize ingot cooling rate and minimize the steepness of the solidus and liquidus isotherms. The knowledge concerning macrosegregation in consumable melted IN-718 is in the form of correlations. Since the isotherm steepness is undoubtedly involved, investigations which include a microgravity environment might separate microsegregation effects from macrosegregation effects. Accounting for the effects of gravity and density differences between the metal pool and the interdendritic fluid, in combination with the pool and mushy zone profiles, can lead to improved melting solidification practices for IN-718, and allow prediction of macrosegregation tendency to be incorporated into high temperature alloy design.

Domingue, J. A.↗

Commissioning of the discrete spot scanning proton beam delivery system at University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston

Purpose: To describe a summary of the clinical commissioning of the discrete spot scanning proton beam at the Proton Therapy Center, Houston (PTC-H). Methods: Discrete spot scanning system is composed of a delivery system (Hitachi ProBeat), an electronic medical record (Mosaiq V 1.5), and a treatment planning system (TPS) (Eclipse V 8.1). Discrete proton pencil beams (spots) are used to deposit dose spot by spot and layer by layer for the proton distal ranges spanning from 4.0 to 30.6 g/cm{sup 2} and over a maximum scan area at the isocenter of 30x30 cm{sup 2}. An arbitrarily chosen reference calibration condition has been selected to define the monitor units (MUs). Using radiochromic film and ion chambers, the authors have measured spot positions, the spot sizes in air, depth dose curves, and profiles for proton beams with various energies in water, and studied the linearity of the dose monitors. In addition to dosimetric measurements and TPS modeling, significant efforts were spent in testing information flow and recovery of the delivery system from treatment interruptions. Results: The main dose monitors have been adjusted such that a specific amount of charge is collected in the monitor chamber corresponding to a single MU, following the IAEA TRS 398 protocol under a specific reference condition. The dose monitor calibration method is based on the absolute dose per MU, which is equivalent to the absolute dose per particle, the approach used by other scanning beam institutions. The full width at half maximum for the spot size in air varies from approximately 1.2 cm for 221.8 MeV to 3.4 cm for 72.5 MeV. The measured versus requested 90% depth dose in water agrees to within 1 mm over ranges of 4.0-30.6 cm. The beam delivery interlocks perform as expected, guarantying the safe and accurate delivery of the planned dose. Conclusions: The dosimetric parameters of the discrete spot scanning proton beam have been measured as part of the clinical commissioning program, and the machine is found to function in a safe manner, making it suitable for patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulating Dynamic Roots in the Energy Exascale Earth System Land Model

Abstract Roots are important contributors to plant development, functioning to provide nutrients and water for plant growth. However, roots and their functions are often simplified in Earth system models, which limit the feedback of root foraging strategy on plant productivity, and their impacts on the carbon cycle. The goal of this study is to introduce a new method to resolve the vertical structure of roots over time. The method allows plasticity of rooting depth distribution under nonuniform profiles of water and nitrogen, which influences aboveground dynamics. The dynamic root model optimizes root distribution for both water and nitrogen uptake but gives priority to plant water demands. I implement this new method in the Energy Exascale Earth System model. The resulting root distribution maintains agreement with observations in most ecosystems and marginally improves the gross primary productivity estimated by the model, compared to satellite observations. Increases in gross primary productivity are simulated in desert and boreal ecosystems. However, the model does not capture deep roots in the dry tropics, and therefore, productivity losses are observed in parts of the Amazon and the African savannah. I discuss details of the model algorithm, along with some sensitivity studies that shed light on the model behavior in water‐limited ecosystems. The study shows that additional model processes, such as climate dependent root depth, root hydraulics, root form and function, and better nitrogen uptake, should be considered to improve the root water uptake in the Energy Exascale Earth System Land Model (ELM).

54 ENVIRONMENTAL SCIENCES↗

Liquid scintillator for 2D dosimetry for high-energy photon beams

Complex radiation therapy techniques require dosimetric verification of treatment planning and delivery. The authors investigated a liquid scintillator (LS) system for application for real-time high-energy photon beam dosimetry. The system was comprised of a transparent acrylic tank filled with liquid scintillating material, an opaque outer tank, and a CCD camera. A series of images was acquired when the tank with liquid scintillator was irradiated with a 6 MV photon beam, and the light data measured with the CCD camera were filtered to correct for scattering of the optical light inside the liquid scintillator. Depth-dose and lateral profiles as well as two-dimensional (2D) dose distributions were found to agree with results from the treatment planning system. Further, the corrected light output was found to be linear with dose, dose rate independent, and is robust for single or multiple acquisitions. The short time needed for image acquisition and processing could make this system ideal for fast verification of the beam characteristics of the treatment machine. This new detector system shows a potential usefulness of the LS for 2D QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating Combined Lidar and Polarimeter Measurements of Cloud Top Parameters (Extinction, Scattering Cross Sections, and Droplet Number Density, Liquid Water Content)

We present a new method to derive profiles of extinction from a lidar which is then combined with polarimeter measurements to derive cloud droplet number density (CDNC) in the tops of warm clouds. The method employs polarization-sensitive elastic backscatter lidar measurements to estimate attenuation of the lidar signal within the cloud and polarimeter estimates of cloud droplet size distributions. The measurements used for this demonstration are from NASA Langley Research Center’s High Spectral Resolution Lidar – Generation 2 (HSRL-2) and NASA GISS’s Research Scanning Polarimeter (RSP). The measurements were acquired on NASA’s ACTIVATE mission, during which the instruments were deployed in a down-looking mode from a high-altitude aircraft, which flew in coordination with a low-flying aircraft acquiring coincident in situ measurements of cloud droplet size and number. The high vertical (1.25 m) and horizontal (~50 m) sampling resolution of the HSRL-2 data enabled retrievals of single-scattering extinction profiles to within ~2.5 optical depths of cloud top. Another key feature of the method was the well-calibrated measurement of backscatter at cloud top due to using the HSRL technique. The RSP retrievals of cloud droplet effective radius and variance were accomplished using the “cloud-bow” technique. Overall, the technique provides extinction profile estimates for the top 2.5 optical depths of water clouds that can be used to estimate the cloud droplet number density in various types of warm clouds. The mean extinction values at cloud top (0-1 optical depth) are compared against cloud drop size and number concentration acquired from wing-mounted probes (e.g., DMT Cloud Droplet Probe - CDP, SPEC Fast Cloud Droplet Probe FCDP, and SPEC 2D Stereo Probe - 2DS) that were deployed on the low-flying aircraft. Comparisons between the effective radius and variance from the polarimeter, lidar ratio (extinction to backscatter) from the lidar and polarimeter, and LWC are also presented. All measurements were acquired over the Western North Atlantic over 3 years from 2020 to 2022.

lidar↗

TU-F-18A-03: Improving Tissue Segmentation for Monte Carlo Dose Calculation Using DECT Data

Purpose: To develop a new segmentation technique using dual energy CT (DECT) to overcome limitations related to segmentation from a standard Hounsfield unit (HU) to electron density (ED) calibration curve. Both methods are compared with a Monte Carlo analysis of dose distribution. Methods: DECT allows a direct calculation of both ED and effective atomic number (EAN) within a given voxel. The EAN is here defined as a function of the total electron cross-section of a medium. These values can be effectively acquired using a calibrated method from scans at two different energies. A prior stoichiometric calibration on a Gammex RMI phantom allows us to find the parameters to calculate EAN and ED within a voxel. Scans from a Siemens SOMATOM Definition Flash dual source system provided the data for our study. A Monte Carlo analysis compares dose distribution simulated by dosxyz-nrc, considering a head phantom defined by both segmentation techniques. Results: Results from depth dose and dose profile calculations show that materials with different atomic compositions but similar EAN present differences of less than 1%. Therefore, it is possible to define a short list of basis materials from which density can be adapted to imitate interaction behavior of any tissue. Comparison of the dose distributions on both segmentations shows a difference of 50% in dose in areas surrounding bone at low energy. Conclusion: The presented segmentation technique allows a more accurate medium definition in each voxel, especially in areas of tissue transition. Since the behavior of human tissues is highly sensitive at low energies, this reduces the errors on calculated dose distribution. This method could be further developed to optimize the tissue characterization based on anatomic site.

60 APPLIED LIFE SCIENCES↗

Monte Carlo validation of the TrueBeam 10XFFF phase–space files for applications in lung SABR

Purpose: To establish the clinical acceptability of universal Monte Carlo phase–space data for the 10XFFF (flattening filter free) photon beam on the Varian TrueBeam Linac, including previously unreported data for small fields, output factors, and inhomogeneous media. The study was particularly aimed at confirming the suitability for use in simulations of lung stereotactic ablative radiotherapy treatment plans. Methods: Monte Carlo calculated percent depth doses (PDDs), transverse profiles, and output factors for the TrueBeam 10 MV FFF beam using generic phase–space data that have been released by the Varian MC research team were compared with in-house measurements and published data from multiple institutions (ten Linacs from eight different institutions). BEAMnrc was used to create field size specific phase–spaces located underneath the jaws. Doses were calculated with DOSXYZnrc in a water phantom for fields ranging from 1 × 1 to 40 × 40 cm{sup 2}. Particular attention was paid to small fields (down to 1 × 1 cm{sup 2}) and dose per pulse effects on dosimeter response for high dose rate 10XFFF beams. Ion chamber measurements were corrected for changes in ion collection efficiency (P{sub ion}) with increasing dose per pulse. MC and ECLIPSE ANISOTROPIC ANALYTICAL ALGORITHM (AAA) calculated PDDs were compared to Gafchromic film measurement in inhomogeneous media (water, bone, lung). Results: Measured data from all machines agreed with Monte Carlo simulations within 1.0% and 1.5% for PDDs and in-field transverse profiles, respectively, for field sizes >1 × 1 cm{sup 2} in a homogeneous water phantom. Agreements in the 80%–20% penumbra widths were better than 2 mm for all the fields that were compared. For all the field sizes considered, the agreement between their measured and calculated output factors was within 1.1%. Monte Carlo results for dose to water at water/bone, bone/lung, and lung/water interfaces as well as within lung agree with film measurements to within 2.8% for 10 × 10 and 3 × 3 cm{sup 2} field sizes. This represents a significant improvement over the performance of the ECLIPSE AAA. Conclusions: The 10XFFF phase–space data offered by the Varian Monte Carlo research team have been validated for clinical use using measured, interinstitutional beam data in water and with film dosimetry in inhomogeneous media.

60 APPLIED LIFE SCIENCES↗

SU-E-T-164: Evaluation of Electron Dose Distribution Using Two Algorithms

Purpose: To appreciate the difference of electron dose distributions calculated from the Monte Carlo and Electron 3D algorithms of radiotherapy in a heterogeneous phantom. Methods: A phantom consisted of two different materials (lungs mimicked by low-density cork and others by polystyrene) with an 11x16 cm field size (SSD = 100 cm) was utilized to estimate the two-dimensional dose distributions under 6 and 18 MeV beams. On behalf of two different types of tissue, the heterogeneous phantom was comprised of 3 identical slabs in the longitudinal direction with a thickness of 1 cm for each slab and 2 with a thickness of 2.5 cm. The Monte Carlo/MCTP application package constituted of five codes was performed to simulate the electron beams of a Varian Clinac 23IX. A 20x20 cm2 type III (open walled) applicator was used in these simulations. It has been shown elsewhere that the agreement of the phase space data between the calculation results of MCTP application package and the measured data were within 2% on depth-dose and transverse profiles, as well as output factor calculations. The electron 3D algorithm owned by Pinnacle 8.0m and the MCTP application package were applied for the two-dimensional dose distributions calculation. The curves at 50% and 100%-prescribed dose were observed for 6 and 18 MeV beams, respectively. Results: The MC calculations results were compared with the electron 3D calculations in terms of two-dimensional dose distributions for 6 and 18 MeV beams showed excellent agreement except in distal boundary where it was the very junction of the high and low-density region. Conclusions: The Monte Carlo/MCTP method could be used to better reflect the dose variation caused by heterogeneous tissues. Conclusion: A case study showed that the Monte Carlo/MCTP method could be used to better reflect the dose variation caused by heterogeneous tissues.

60 APPLIED LIFE SCIENCES↗

Diffusion instability in a bimodal disc

A simplified model of radial diffusion in a planetary disk with a bimodal size distribution is presented. The large particle component excites the small particles' dispersion velocity via gravitational scattering. The resulting small particle viscous stress goes through a maximum near optical depth = sq root 3. Such a stress profile promotes the development of high and low optical depth zones. The resulting ringlet appearance is due primarily to the distribution of small particles, which produce most of the optical depth but may constitute only a minor portion of system mass.

Ward, W. R.↗

Monte Carlo simulation of an x-ray volume imaging cone beam CT unit

In this work the authors characterized the radiation field produced by a kilovolt cone beam computed tomography (CBCT) unit integrated in the Elekta Synergy linear accelerator. The x-ray volume imaging (XVI) radiation unit was modeled in detail using the BEAMNRC Monte Carlo (MC) code system. The simulations of eight collimator cassettes and the neutral filter F0 were successfully carried out. MC calculations from the EGSNRC code DOSXYZNRC were benchmarked against measurements in water. A large set of depth dose and lateral profiles was acquired with the ionization chamber in water, with the x-ray tube in a stationary position, and with the beam energy set to 120 kV. Measurements for all the available collimator cassettes were compared with calculations, showing very good agreement (<2% in most cases). Furthermore, half value layer measurements were carried out and used to validate the MC model of the XVI unit. In this case dose calculations were performed with the EGSNRC code cavity and these showed excellent agreement. In this manuscript the authors also report on the optimization work of the relevant parameters that influenced the development of the MC model. The dosimetric part of this work was very useful in characterizing the XVI radiation output for the energy of interest. The detailed simulation part of the work is the first step toward an accurate MC based assessment of the dose delivered to patients during routine CBCT scans for image and dose guided radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗