Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Two-dimensional single crystal diamond refractive x-ray lens

The next generation light sources such as diffraction-limited storage rings and high repetition rate x-ray free-electron lasers will generate x-ray beams with significantly increased brilliance. These future machines will require X-ray optical components that are capable of handling higher instantaneous and average power densities while tailoring the properties of the x-ray beams for a variety of scientific experiments. Single crystal diamond is one of the best bulk materials for this application, because it is radiation hard, has a suitable uniform index of refraction and the best available thermal properties. In this paper we report on fabrication and experimental testing of a two-dimensional (2D) single crystal diamond compound refractive X-ray lenses (CRL). These lenses were manufactured using femto-second laser cutting and tested at the Advanced Photon Source of Argonne National Laboratory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

30-lens interferometer for high energy x-rays

We report a hard X-ray multilens interferometer consisting of 30 parallel compound refractive lenses. Under coherent illumination each CRL creates a diffraction limited focal spot - secondary source. An overlapping of coherent beams from these sources resulting in the interference pattern which has a rich longitudinal structure in accordance with the Talbot imaging formalism. The proposed interferometer was experimentally tested at ID11 ESRF beamline for the photon energies 32 keV and 65 keV. The fundamental and fractional Talbot images were recorded with the high resolution CCD camera. An effective source size in the order of 15 µm was determined from the first Talbot image proving that the multilens interferometer can be used as a high resolution beam diagnostic tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental analysis of a novel and low-cost pin photodiode dosimetry system for diagnostic radiology

Silicon PIN photodiode has recently found broad and exciting applications in the ionizing radiation dosimetry. In this study a compact and novel dosimetry system using a commercially available PIN photodiode (BPW34) has been experimentally tested for diagnostic radiology. The system was evaluated with clinical beams routinely used for diagnostic radiology and calibrated using a secondary reference standard. Measured dose with PIN photodiode (Air Kerma) varied from 10 to 430 μGy for tube voltages from 40 to 100 kVp and tube current from 0.4 to 40 mAs. The minimum detectable organ dose was estimated to be 10 μGy with 20% uncertainty. Results showed a linear correlation between the PIN photodiode readout and dose measured with standard dosimeters spanning doses received. The present dosimetry system having advantages of suitable sensitivity with immediate readout of dose values, low cost, and portability could be used as an alternative to passive dosimetry system such as thermoluminescent dosimeter for dose measurements in diagnostic radiology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mode splitting effect in FEMs with oversized Bragg resonators

Splitting of the fundamental mode in an oversized Bragg resonator with a step of the corrugation phase, which operates over the feedback loop involving the waveguide waves of different transverse structures, was found to be the result of mutual influence of the neighboring zones of the Bragg scattering. Theoretical description of this effect was developed within the framework of the advanced (four-wave) coupled-wave approach. It is shown that mode splitting reduces the selective properties, restricts the output power, and decreases the stability of the narrow-band operating regime in the free-electron maser (FEM) oscillators based on such resonators. The results of the theoretical analysis were confirmed by 3D simulations and “cold” microwave tests. Experimental data on Bragg resonators with different parameters in a 30-GHz FEM are presented. The possibility of reducing the mode splitting by profiling the corrugation parameters is shown. The use of the mode splitting effect for the output power enhancement by passive compression of the double-frequency pulse generated in the FEM with such a resonator is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of silica quartz as raw material in photovoltaic applications

Raw materials are essential for the functioning of modern societies, and access to these raw materials is vital to the world economy. Sustainable development, both globally level, raises important new challenges associated with access and efficient use of raw materials. High purity quartz, is consider as a critical raw material and it is a rare commodity that only forms under geological conditions where a narrow set of chemical and physical parameters is fulfilled. When identified and following special beneficiation techniques, high purity quartz obtains very attractive prices and is applied in high technology sectors that currently are under rapid expansion such as photovoltaic solar cells, silicon metal - oxide wafers in the semiconductor industry and long distance optical fibers that are used in communication networks. Crystalline silicon remains the principal material for photovoltaic technology. Metallurgical silicon is produced industrially by the reduction of silica with carbon in an electric arc furnace at temperatures higher than 2000 °C in the hottest parts, by a reaction that can be written ideally as: SiO{sub 2} + 2C = Si + 2CO. The aim of this study has been to test experimental methods for investigating the various physical and chemical proprieties of Hoggar quartz with different techniques: X Ray Fluorescence, infra-red spectroscopy, Scanning Electron Microscopy, Optic Microscopy, Carbon Analyzer and Vickers Hardness. The results show finally that the quartz has got good result in purity but need enrichment for the photovoltaic application.

36 MATERIALS SCIENCE↗

Characterization of compact-toroid injection during formation, translation, and field penetration

We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ∼1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuning the heat transfer medium and operating conditions in magnetic refrigeration

A new experimental test bed has been designed, built, and tested to evaluate the effect of the system’s parameters on a reciprocating Active Magnetic Regenerator (AMR) near room temperature. Bulk gadolinium was used as the refrigerant, silicon oil as the heat transfer medium, and a magnetic field of 1.3 T was cycled. This study focuses on the methodology of single stage AMR operation conditions to get a high temperature span near room temperature. Herein, the main objective is not to report the absolute maximum attainable temperature span seen in an AMR system, but rather to find the system’s optimal operating conditions to reach that maximum span. The results of this research show that there is a optimal operating frequency, heat transfer fluid flow rate, flow duration, and displaced volume ratio in any AMR system. By optimizing these parameters in our AMR apparatus the temperature span between the hot and cold ends increased by 24%. The optimized values are system dependent and need to be determined and measured for any AMR system by following the procedures that are introduced in this research. It is expected that such optimization will permit the design of a more efficient magnetic refrigeration system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of excess carriers on charged defect concentrations in wide bandgap semiconductors

Unintentional doping and doping limits in semiconductors are typically caused by compensating defects with low formation energies. Since the formation enthalpy of a charged defect depends linearly on the Fermi level, doping limits can be especially pronounced in wide bandgap semiconductors where the Fermi level can vary substantially. Introduction of non-equilibrium carrier concentrations during growth or processing alters the chemical potentials of band carriers and allows populations of charged defects to be modified in ways impossible at thermal equilibrium. We demonstrate that in the presence of excess carriers, the rates of carrier capture and emission involving a defect charge transition level determine the admixture of electron and hole quasi-Fermi levels involved in the formation enthalpy of non-zero charge defect states. To understand the range of possible responses, we investigate the behavior of a single donor-like defect as functions of extrinsic doping and charge transition level energy. We find that that excess carriers will increase the formation enthalpy of compensating defects for most values of the charge transition level in the bandgap. Thus, it may be possible to use non-equilibrium carrier concentrations to overcome limitations on doping imposed by native defects. Cases also exist in which the concentration of defects with the same charge polarity as the majority dopant is either left unchanged or actually increases. This surprising effect arises when emission rates are suppressed relative to the capture rates and is most pronounced in wide bandgap semiconductors. We provide guidelines for carrying out experimental tests of this model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging nanoscale spatial modulation of a relativistic electron beam with a MeV ultrafast electron microscope

Here, an accelerator-based MeV ultrafast electron microscope (MUEM) has been proposed as a promising tool to the study structural dynamics at the nanometer spatial scale and the picosecond temporal scale. Here, we report experimental tests of a prototype MUEM where high quality images with nanoscale fine structures were recorded with a pulsed ~3 MeV picosecond electron beam. The temporal and spatial resolutions of the MUEM operating in the single-shot mode are about 4 ps (FWHM) and 100 nm (FWHM), corresponding to a temporal-spatial resolution of 4 × 10 –19 sm, about 2 orders of magnitude higher than that achieved with state-of-the-art single-shot keV UEM. Using this instrument, we offer the demonstration of visualizing the nanoscale periodic spatial modulation of an electron beam, which may be converted into longitudinal density modulation through emittance exchange to enable production of high-power coherent radiation at short wavelengths. Our results mark a great step towards single-shot nanometer-resolution MUEMs and compact intense x-ray sources that may have widespread applications in many areas of science.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated plasma facing component calorimetry for measurement of shot integrated deposited energy in the NSTX-U

Here, the upgrade to the National Spherical Torus eXperiment (NSTX-U) increases the injected neutral beam power up to 12 MW and the plasma current up to I p = 2 MA for plasma durations up to 5 s. The graphite plasma facing components have been re-designed to handle greater heat and energy fluxes than were seen in NSTX using a castellated design. We present the experimental testing and validation of a castellated graphite target, similar to the prototype tile design, instrumented with thermocouples at various depths in the castellation. During testing, incident heat flux is provided by a programmed electron beam system and surface temperatures are measured via infrared thermography directly viewing the target surface. It was found that the thermocouple response scaled linearly with the measured surface temperature rise regardless of thermocouple depth in the castellation. A sensitivity of 14.3 °C/kJ of deposited energy was found when treating individual castellations as a semi-infinite solid.

47 OTHER INSTRUMENTATION↗

Electrostatic subframing and compressive-sensing video in transmission electron microscopy

We present kilohertz-scale video capture rates in a transmission electron microscope, using a camera normally limited to hertz-scale acquisition. An electrostatic deflector rasters a discrete array of images over a large camera, decoupling the acquisition time per subframe from the camera readout time. Total-variation regularization allows features in overlapping subframes to be correctly placed in each frame. Moreover, the system can be operated in a compressive-sensing video mode, whereby the deflections are performed in a known pseudorandom sequence. Compressive sensing in effect performs data compression before the readout, such that the video resulting from the reconstruction can have substantially more total pixels than that were read from the camera. This allows, for example, 100 frames of video to be encoded and reconstructed using only 15 captured subframes in a single camera exposure. We demonstrate experimental tests including laser-driven melting/dewetting, sintering, and grain coarsening of nanostructured gold, with reconstructed video rates up to 10 kHz. The results exemplify the power of the technique by showing that it can be used to study the fundamentally different temporal behavior for the three different physical processes. Both sintering and coarsening exhibited self-limiting behavior, whereby the process essentially stopped even while the heating laser continued to strike the material. We attribute this to changes in laser absorption and to processes inherent to thin-film coarsening. In contrast, the dewetting proceeded at a relatively uniform rate after an initial incubation time consistent with the establishment of a steady-state temperature profile.

36 MATERIALS SCIENCE↗

Implementation of a Talbot–Lau x-ray deflectometer diagnostic platform for the OMEGA EP laser

A Talbot–Lau X-ray Deflectometer (TXD) was implemented in the OMEGA EP laser facility to characterize the evolution of an irradiated foil ablation front by mapping electron densities >10 22 cm -3 by means of Moiré deflectometry. The experiment used a short-pulse laser (30–100 J, 10 ps) and a foil copper target as an x-ray backlighter source. In the first experimental tests performed to benchmark the diagnostic platform, grating survival was demonstrated and x-ray backlighter laser parameters that deliver Moiré images were described. Finally, the necessary modifications to accurately probe the ablation front through TXD using the EP-TXD diagnostic platform are discussed.

36 MATERIALS SCIENCE↗

Computational catalyst discovery: Active classification through myopic multiscale sampling

We report the recent boom in computational chemistry has enabled several projects aimed at discovering useful materials or catalysts. We acknowledge and address two recurring issues in the field of computational catalyst discovery. First, calculating macro-scale catalyst properties is not straightforward when using ensembles of atomic-scale calculations [e.g., density functional theory (DFT)]. We attempt to address this issue by creating a multi-scale model that estimates bulk catalyst activity using adsorption energy predictions from both DFT and machine learning models. The second issue is that many catalyst discovery efforts seek to optimize catalyst properties, but optimization is an inherently exploitative objective that is in tension with the explorative nature of early-stage discovery projects. In other words, why invest so much time finding a “best” catalyst when it is likely to fail for some other, unforeseen problem? We address this issue by relaxing the catalyst discovery goal into a classification problem: “What is the set of catalysts that is worth testing experimentally?” Here, we present a catalyst discovery method called myopic multiscale sampling, which combines multiscale modeling with automated selection of DFT calculations. It is an active classification strategy that seeks to classify catalysts as “worth investigating” or “not worth investigating” experimentally. Our results show an ~7–16 times speedup in catalyst classification relative to random sampling. These results were based on offline simulations of our algorithm on two different datasets: a larger, synthesized dataset and a smaller, real dataset.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluid structure interaction of a subaqueous pendulum: Analyzing the effect of wake correction via large eddy simulations

The dynamic behavior of a subaqueous cylindrical pendulum and corresponding flow dynamics are investigated. The objectives were twofold: (i) to examine whether the two-dimensional model equations sufficiently capture the three-dimensional dynamics and (ii) to investigate the emerging three-dimensional vortical flow structures. Large eddy simulations with two-way coupling fluid structure interaction were carried out using the immersed boundary method to simulate the motion of the pendulum and its interactions with the initially stagnant water. The resulting pendulum motion is compared against measured data obtained in a series of experimental tests to validate the simulation results and the model equations with and without wake corrections. An analysis of the flow vorticity revealed the development of a vortex ring during the first swing and the formation of tip vortices. The evolution of the vortex rings emerging from the motion of the subaqueous cylindrical pendulum was visualized using Q-criteria showing a reasonable agreement with vortical structures observed in the experiment using particle imaging velocimetry. The hydrodynamic moments acting on the simulated pendulum and the moments calculated from the model equations are analyzed. Using the insights from these numerical simulations, a modification of the wake correction is proposed to enhance the accuracy of the rate of decay and period. The transient effect of coherent flow on pendulum dynamics, especially the added mass effect, is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Platform for probing radiation transport properties of hydrogen at conditions found in the deep interiors of red dwarfs

We describe an experimental concept at the National Ignition Facility for specifically tailored spherical implosions to compress hydrogen to extreme densities (up to ∼800× solid density, electron number density ne∼4×1025 cm−3) at moderate temperatures (T∼200 eV), i.e., to conditions, which are relevant to the interiors of red dwarf stars. The dense plasma will be probed by laser-generated x-ray radiation of different photon energy to determine the plasma opacity due to collisional (free–free) absorption and Thomson scattering. The obtained results will benchmark radiation transport models, which in the case for free–free absorption show strong deviations at conditions relevant to red dwarfs. This very first experimental test of free–free opacity models at these extreme states will help to constrain where inside those celestial objects energy transport is dominated by radiation or convection. Moreover, our study will inform models for other important processes in dense plasmas, which are based on electron–ion collisions, e.g., stopping of swift ions or electron–ion temperature relaxation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tuning perovskite nanocrystal superlattices for superradiance in the presence of disorder

The cooperative emission of interacting nanocrystals is an exciting topic fueled by recent reports of superfluorescence and superradiance in assemblies of perovskite nanocubes. Several studies estimated that coherent coupling is localized to a small fraction of nanocrystals (10 -7 –10 -3 ) within the assembly, raising questions about the origins of localization and ways to overcome it. In this work, we examine single-excitation superradiance by calculating radiative decays and the distribution of superradiant wave function in two-dimensional CsPbBr 3 nanocube superlattices. The calculations reveal that the energy disorder caused by size distribution and large interparticle separations reduces radiative coupling and leads to the excitation localization, with the energy disorder being the dominant factor. The single-excitation model clearly predicts that, in the pursuit of cooperative effects, having identical nanocubes in the superlattice is more important than achieving a perfect spatial order. The monolayers of large CsPbBr 3 nanocubes (L NC = 10–20 nm) are proposed as model systems for experimental tests of superradiance under conditions of non-negligible size dispersion, while small nanocubes (L NC = 5–10 nm) are preferred for realizing the Dicke state under ideal conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excess Density as a Descriptor for Electrolyte Solvent Design

Electrolytes mediate interactions between the cathode and anode and determine performance characteristics of batteries. Mixtures of multiple solvents are often used in electrolytes to achieve desired properties, such as viscosity, dielectric constant, boiling point, and melting point. Conventionally, multi-component electrolyte properties are approximated with linear mixing, but in practice, significant deviations are observed. Excess quantities can provide insights into the molecular behavior of the mixture and could form the basis for designing high-performance electrolytes. Here we investigate the excess density of commonly used Li-ion battery solvents such as cyclic carbonates, linear carbonates, ethers, and nitriles with molecular dynamics simulations. We additionally investigate electrolytes consisting of these solvents and a salt. The results smoothly vary with mole percent and are fit to permutation-invariant Redlich-Kister polynomials. Mixtures of similar solvents, such as cyclic-cyclic carbonate mixtures, tend to have excess properties that are lower in magnitude compared to mixtures of dissimilar substances, such as carbonate-nitrile mixtures. We perform experimental testing using our automated test stand, Clio, to provide validation to the observed simulation trends. We quantify the structure similarity using SOAP fingerprints to create a descriptor for excess density, enabling the design of electrolyte properties. To a first approximation, this will allow us to estimate the deviation of a mixture from ideal behavior based solely upon the structural dissimilarity of the components.

74 ATOMIC AND MOLECULAR PHYSICS↗

A compact low-level RF control system for advanced concept compact electron linear accelerator

A compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF performance and size, weight, and power consumption (SWaP). The compact LLRF solution employs the direct RF sampling technique of RFSoC, which samples the RF signals directly without any analog upconversion and downconversion. Compared with the conventional heterodyne based architecture used for the LLRF system of a linear accelerator (LINAC), the elimination of analog mixers can significantly reduce the size and weight of the system, especially with LINAC requiring a larger number of RF channels. Based on the requirements of ACCEL, a prototype LLRF platform has been developed, and the control schemes have been proposed. The prototype LLRF system demonstrated magnitude and phase fluctuation levels below 1% and 1° on the flattop of a 2 μs RF pulse. The LLRF control schemes proposed for ACCEL are implemented with a prototype hardware platform. In conclusion, this paper will introduce the new compact LLRF solution and summarize a selection of experimental test results of the prototype itself and with the accelerating structure cavities designed for ACCEL.

Liu, C. [SLAC National Accelerator Laboratory (SLA↗