Search NASA⌕ Search

SEARCH · Search NASA

Results for “failure analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Independent Orbiter Assessment (IOA): Assessment of the orbiter main propulsion system FMEA/CIL, volume 1

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Main Propulsion System (MPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to available data from the Rockwell Downey/NASA JSC FMEA/CIL review. The Orbiter MPS is composed of the Propellant Management Subsystem (PMS) consisting of the liquid oxygen (LO2) and liquid hydrogen (LH2) subsystems and the helium subsystem. The PMS is a system of manifolds, distribution lines, and valves by which the liquid propellants pass from the External Tank to the Space Shuttle Main Engine (SSME). The helium subsystem consists of a series of helium supply tanks and their associated regulators, control valves, and distribution lines. Volume 1 contains the MPS description, assessment results, ground rules and assumptions, and some of the IOA worksheets.

Slaughter, B. C.↗

Independent Orbiter Assessment (IOA): Assessment of the main propulsion subsystem FMEA/CIL, volume 2

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Main Propulsion System (MPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were than compared to available data from the Rockwell Downey/NASA JSC FMEA/CIL review. Volume 2 continues the presentation of IOA worksheets for MPS hardware items.

Holden, K. A.↗

Independent Orbiter Assessment (IOA): Assessment of the main propulsion subsystem FMEA/CIL, volume 3

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Main Propulsion System (MPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to available data from the Rockwell Downey/NASA JSC FMEA/CIL review. Volume 3 continues the presentation of IOA worksheets and includes the potential critical items list.

Holden, K. A.↗

Independent Orbiter Assessment (IOA): Assessment of the main propulsion subsystem FMEA/CIL, volume 4

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Main Propulsion System (MPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were than compared to available data from the Rockwell Downey/NASA JSC FMEA/CIL review. Volume 4 contains the IOA analysis worksheets and the NASA FMEA to IOA worksheet cross reference and recommendations.

Slaughter, B. C.↗

Reliability Impacts in Life Support Architecture and Technology Selection

Equivalent System Mass (ESM) and reliability estimates were performed for different life support architectures based primarily on International Space Station (ISS) technologies. The analysis was applied to a hypothetical 1-year deep-space mission. High-level fault trees were initially developed relating loss of life support functionality to the Loss of Crew (LOC) top event. System reliability was then expressed as the complement (nonoccurrence) this event and was increased through the addition of redundancy and spares, which added to the ESM. The reliability analysis assumed constant failure rates and used current projected values of the Mean Time Between Failures (MTBF) from an ISS database where available. Results were obtained showing the dependence of ESM on system reliability for each architecture. Although the analysis employed numerous simplifications and many of the input parameters are considered to have high uncertainty, the results strongly suggest that achieving necessary reliabilities for deep-space missions will add substantially to the life support system mass. As a point of reference, the reliability for a single-string architecture using the most regenerative combination of ISS technologies without unscheduled replacement spares was estimated to be less than 1%. The results also demonstrate how adding technologies in a serial manner to increase system closure forces the reliability of other life support technologies to increase in order to meet the system reliability requirement. This increase in reliability results in increased mass for multiple technologies through the need for additional spares. Alternative parallel architecture approaches and approaches with the potential to do more with less are discussed. The tall poles in life support ESM are also reexamined in light of estimated reliability impacts.

Lange, Kevin E.↗

Failure to Adhere to Protocol Specified Radiation Therapy Guidelines Was Associated With Decreased Survival in RTOG 9704-A Phase III Trial of Adjuvant Chemotherapy and Chemoradiotherapy for Patients With Resected Adenocarcinoma of the Pancreas

Purpose: In Radiation Therapy Oncology Group 9704, as previously published, patients with resected pancreatic adenocarcinoma received continuous infusion 5-FU and concurrent radiotherapy (5FU-RT). 5FU-RT treatment was preceded and followed by randomly assigned chemotherapy, either 5-FU or gemcitabine. This analysis explored whether failure to adhere to specified RT guidelines influenced survival and/or toxicity. Methods and Materials: RT requirements were protocol specified. Adherence was scored as per protocol (PP) or less than per protocol (<PP). Scoring occurred after therapy but before trial analysis and without knowledge of individual patient treatment outcomes. Scoring was done for all tumor locations and for the subset of pancreatic head location. Results: RT was scored for 416 patients: 216 PP and 200 <PP. For all pancreatic sites (head, body/tail) median survival (MS) for PP vs. <PP was 1.74 vs. 1.46 years (log-rank p = 0.0077). In multivariate analysis, PP vs. <PP score correlated more strongly with MS than assigned treatment arm (p = 0.014, p = NS, respectively); for patients with pancreatic head tumors, both PP score and gemcitabine treatment correlated with improved MS (p = 0.016, p = 0.043, respectively). For all tumor locations, PP score was associated with decreased risk of failure (p = 0.016) and, for gemcitabine patients, a trend toward reduced Grade 4/5 nonhematologic toxicity (p = 0.065). Conclusions: This is the first Phase III, multicenter, adjuvant protocol for pancreatic adenocarcinoma to evaluate the impact of adherence to specified RT protocol guidelines on protocol outcomes. Failure to adhere to specified RT guidelines was associated with reduced survival and, for patients receiving gemcitabine, trend toward increased nonhematologic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-AB-BRD-00: Task Group 100

Current quality assurance and quality management guidelines provided by various professional organizations are prescriptive in nature, focusing principally on performance characteristics of planning and delivery devices. However, published analyses of events in radiation therapy show that most events are often caused by flaws in clinical processes rather than by device failures. This suggests the need for the development of a quality management program that is based on integrated approaches to process and equipment quality assurance. Industrial engineers have developed various risk assessment tools that are used to identify and eliminate potential failures from a system or a process before a failure impacts a customer. These tools include, but are not limited to, process mapping, failure modes and effects analysis, fault tree analysis. Task Group 100 of the American Association of Physicists in Medicine has developed these tools and used them to formulate an example risk-based quality management program for intensity-modulated radiotherapy. This is a prospective risk assessment approach that analyzes potential error pathways inherent in a clinical process and then ranks them according to relative risk, typically before implementation, followed by the design of a new process or modification of the existing process. Appropriate controls are then put in place to ensure that failures are less likely to occur and, if they do, they will more likely be detected before they propagate through the process, compromising treatment outcome and causing harm to the patient. Such a prospective approach forms the basis of the work of Task Group 100 that has recently been approved by the AAPM. This session will be devoted to a discussion of these tools and practical examples of how these tools can be used in a given radiotherapy clinic to develop a risk based quality management program. Learning Objectives: Learn how to design a process map for a radiotherapy process Learn how to perform failure modes and effects analysis analysis for a given process Learn what fault trees are all about Learn how to design a quality management program based upon the information obtained from process mapping, failure modes and effects analysis and fault tree analysis. Dunscombe: Director, TreatSafely, LLC and Center for the Assessment of Radiological Sciences; Consultant to IAEA and Varian Thomadsen: President, Center for the Assessment of Radiological Sciences Palta: Vice President of the Center for the Assessment of Radiological Sciences.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRD-01: Process Mapping

Current quality assurance and quality management guidelines provided by various professional organizations are prescriptive in nature, focusing principally on performance characteristics of planning and delivery devices. However, published analyses of events in radiation therapy show that most events are often caused by flaws in clinical processes rather than by device failures. This suggests the need for the development of a quality management program that is based on integrated approaches to process and equipment quality assurance. Industrial engineers have developed various risk assessment tools that are used to identify and eliminate potential failures from a system or a process before a failure impacts a customer. These tools include, but are not limited to, process mapping, failure modes and effects analysis, fault tree analysis. Task Group 100 of the American Association of Physicists in Medicine has developed these tools and used them to formulate an example risk-based quality management program for intensity-modulated radiotherapy. This is a prospective risk assessment approach that analyzes potential error pathways inherent in a clinical process and then ranks them according to relative risk, typically before implementation, followed by the design of a new process or modification of the existing process. Appropriate controls are then put in place to ensure that failures are less likely to occur and, if they do, they will more likely be detected before they propagate through the process, compromising treatment outcome and causing harm to the patient. Such a prospective approach forms the basis of the work of Task Group 100 that has recently been approved by the AAPM. This session will be devoted to a discussion of these tools and practical examples of how these tools can be used in a given radiotherapy clinic to develop a risk based quality management program. Learning Objectives: Learn how to design a process map for a radiotherapy process Learn how to perform failure modes and effects analysis analysis for a given process Learn what fault trees are all about Learn how to design a quality management program based upon the information obtained from process mapping, failure modes and effects analysis and fault tree analysis. Dunscombe: Director, TreatSafely, LLC and Center for the Assessment of Radiological Sciences; Consultant to IAEA and Varian Thomadsen: President, Center for the Assessment of Radiological Sciences Palta: Vice President of the Center for the Assessment of Radiological Sciences.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRD-04: Development of Quality Management Program

Current quality assurance and quality management guidelines provided by various professional organizations are prescriptive in nature, focusing principally on performance characteristics of planning and delivery devices. However, published analyses of events in radiation therapy show that most events are often caused by flaws in clinical processes rather than by device failures. This suggests the need for the development of a quality management program that is based on integrated approaches to process and equipment quality assurance. Industrial engineers have developed various risk assessment tools that are used to identify and eliminate potential failures from a system or a process before a failure impacts a customer. These tools include, but are not limited to, process mapping, failure modes and effects analysis, fault tree analysis. Task Group 100 of the American Association of Physicists in Medicine has developed these tools and used them to formulate an example risk-based quality management program for intensity-modulated radiotherapy. This is a prospective risk assessment approach that analyzes potential error pathways inherent in a clinical process and then ranks them according to relative risk, typically before implementation, followed by the design of a new process or modification of the existing process. Appropriate controls are then put in place to ensure that failures are less likely to occur and, if they do, they will more likely be detected before they propagate through the process, compromising treatment outcome and causing harm to the patient. Such a prospective approach forms the basis of the work of Task Group 100 that has recently been approved by the AAPM. This session will be devoted to a discussion of these tools and practical examples of how these tools can be used in a given radiotherapy clinic to develop a risk based quality management program. Learning Objectives: Learn how to design a process map for a radiotherapy process Learn how to perform failure modes and effects analysis analysis for a given process Learn what fault trees are all about Learn how to design a quality management program based upon the information obtained from process mapping, failure modes and effects analysis and fault tree analysis. Dunscombe: Director, TreatSafely, LLC and Center for the Assessment of Radiological Sciences; Consultant to IAEA and Varian Thomadsen: President, Center for the Assessment of Radiological Sciences Palta: Vice President of the Center for the Assessment of Radiological Sciences.

60 APPLIED LIFE SCIENCES↗

Technology integration box beam failure study

Composite structures have the potential to be cost-effective, structurally efficient primary aircraft structures. The Advanced Composites Technology (ACT) Program has the goal to develop the technology to exploit this potential for heavily loaded aircraft structures. As part of the ACT Program, Lockheed Aeronautical Systems Company completed the design and fabrication of the Technology Integration Box Beam (TIBB). The TIBB is an advanced composite prototype structure for the center wing section of the C-130 aircraft. Lockheed subjected the TIBB to downbending, upbending, torsion and combined upbending and torsion load conditions to verify the design. The TIBB failed at 83 percent of design ultimate load for the combined upbending and torsion load condition. The objective of this paper is to describe the mechanisms that led to the failure of the TIBB. The results of a comprehensive analytical and experimental study are presented. Analytical results include strain and deflection results from both a global analysis of the TIBB and a local analysis of the failure region. These analytical results are validated by experimental results from the TIBB tests. The analytical and experimental results from the TIBB tests are used to determine a sequence of events that resulted in failure of the TIBB. A potential cause of failure is high stresses in a stiffener runout region. Analytical and experimental results are also presented for a stiffener runout specimen that was used to simulate the TIBB failure mechanisms.

Shuart, M. J.↗

A computer aided treatment event recognition system in radiation therapy

Purpose: To develop an automated system to safeguard radiation therapy treatments by analyzing electronic treatment records and reporting treatment events. Methods: CATERS (Computer Aided Treatment Event Recognition System) was developed to detect treatment events by retrieving and analyzing electronic treatment records. CATERS is designed to make the treatment monitoring process more efficient by automating the search of the electronic record for possible deviations from physician's intention, such as logical inconsistencies as well as aberrant treatment parameters (e.g., beam energy, dose, table position, prescription change, treatment overrides, etc). Over a 5 month period (July 2012–November 2012), physicists were assisted by the CATERS software in conducting normal weekly chart checks with the aims of (a) determining the relative frequency of particular events in the authors’ clinic and (b) incorporating these checks into the CATERS. During this study period, 491 patients were treated at the University of Iowa Hospitals and Clinics for a total of 7692 fractions. Results: All treatment records from the 5 month analysis period were evaluated using all the checks incorporated into CATERS after the training period. About 553 events were detected as being exceptions, although none of them had significant dosimetric impact on patient treatments. These events included every known event type that was discovered during the trial period. A frequency analysis of the events showed that the top three types of detected events were couch position override (3.2%), extra cone beam imaging (1.85%), and significant couch position deviation (1.31%). The significant couch deviation is defined as the number of treatments where couch vertical exceeded two times standard deviation of all couch verticals, or couch lateral/longitudinal exceeded three times standard deviation of all couch laterals and longitudinals. On average, the application takes about 1 s per patient when executed on either a desktop computer or a mobile device. Conclusions: CATERS offers an effective tool to detect and report treatment events. Automation and rapid processing enables electronic record interrogation daily, alerting the medical physicist of deviations potentially days prior to performing weekly check. The output of CATERS could also be utilized as an important input to failure mode and effects analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Independent Orbiter Assessment (IOA): Assessment of the communication and tracking subsystem, volume 2

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed and analysis of the Communication and Tracking hardware, generating draft failure modes and potential critical items. The IOA results were then compared to the NASA FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter Communication and Tracking hardware. Volume 2 continues the presentation of IOA worksheets.

Long, W. C.↗

Independent Orbiter Assessment (IOA): Assessment of the communication and tracking subsystem, volume 3

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed and analysis of the Communication and Tracking hardware, generating draft failure modes and potential critical items. The IOA results were then compared to the NASA FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter Communication and Tracking hardware. Volume 3 continues the presentation of IOA worksheets and contains the potential critical items list, detailed analysis, and the NASA FMEA to IOA worksheet cross reference and recommendations.

Long, W. C.↗

Geomechanical characterization of Rock Valley carbonates

In Rock Valley, Nevada, the USA, past earthquake sequences and shallow faulting in Paleozoic carbonates remain poorly understood. Carbonates are typically more ductile rocks that do not experience large stress drops or fracture coalescence, which contradicts previous observations in the region. As part of the Source Physics Experiment, an effort has been made to experimentally characterize the petrophysical and geomechanical properties of carbonates from Rock Valley. Well core and outcrop samples were used to determine the difference between shallow-buried Tertiary limestones and deeply buried Paleozoic limestones and dolostones. The carbonates possessed porosities between 3 and 9%, with V P and V S in the Tertiary carbonates around 2700 and 1800 m/s, respectively, and 6000 and 3100 m/s, respectively, in the Paleozoic carbonates. Microstructural characterization revealed that the Paleozoic carbonates contained significantly more pre-existing damage and alteration than the Tertiary carbonates, though the deformation varies from localized to diffuse. Unconfined Brazilian tests and triaxial tests with confining pressures between 0 and 50 MPa showed that, although samples all experienced failure, the dolostones typically failed at greater stresses and possessed greater E/ν ratios than the limestones. Furthermore, the Hoek–Brown failure criterion was used to construct failure envelopes with the compressive and tensile failure tests. Velocity, density, and porosity measurements were used to construct a hypothetical velocity-depth profile and compare the results with the theoretical petrophysical measurements. Using brittleness analysis, the likely failure conditions were determined to be low-porosity dolomitic rock for fault nucleation in the Paleozoic basement.

Brittleness↗

Analysis and improvements of fringe jump corrections by electronics on the JET tokamak far infrared interferometer

For the Tore Supra interferometer phase measurements, an electronics had been developed electronics using field programmable gate array processors. The embedded algorithm can correct the fringe jumps. For comparison, the electronics ran at JET during the 2009 campaign. The first analysis concluded that the electronics was not correcting all the fringe jumps. An analysis of the failures led to improvements in the algorithm, which was tested during the rest of the campaign. In this article, we evaluate the increases in the performance. From the analysis of the remaining faults, further improvements are discussed for designing future boards that are foreseen for JET using the second wavelength and the Cotton-Mouton effect information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Immersion Cooling of Electronics in DoD Installations

A considerable amount of energy is consumed to cool electronic equipment in data centers. A method for substantially reducing the energy needed for this cooling was demonstrated. The method involves immersing electronic equipment in a non-conductive liquid that changes phase from a liquid to a gas. The liquid used was 3M Novec 649. Two-phase immersion cooling using this liquid is not viable at this time. The primary obstacles are IT equipment failures and costs. However, the demonstrated technology met the performance objectives for energy efficiency and greenhouse gas reduction. Before commercialization of this technology can occur, a root cause analysis of the failures should be completed, and the design changes proven.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PSA Bounce and Biochemical Failure After Brachytherapy for Prostate Cancer: A Study of 820 Patients With a Minimum of 3 Years of Follow-Up

Purpose: To determine clinical or dosimetric factors associated with a prostate-specific antigen (PSA) bounce, as well as an association between a PSA bounce and biochemical relapse-free survival (bRFS), in patients treated with iodine-125 brachytherapy. Methods and Materials: A variety of clinical and treatment factors were examined in 820 patients who had a minimum of 3 years of PSA follow-up with T1-T2cN0M0 prostate cancer. Four different PSA threshold values were used for defining a PSA bounce: a PSA rise of {>=}0.2, {>=}0.4, {>=}0.6, and {>=}0.8 ng/mL. Results: A PSA bounce of {>=}0.2, {>=}0.4, {>=}0.6, and {>=}0.8 ng/mL was noted in 247 patients (30.1%), 161 (19.6%), 105 (12.8%), and 78 (9.5%), respectively. The median time to the first PSA rise was 17.4, 16.25, 16.23, and 15.71 months, respectively, vs. 34.35 months for a biochemical failure (p < 0.0001). A PSA rise of {>=}0.2 ng/mL was the only definition for which there was a significant difference in bRFS between bounce and non-bounce patients. The 5-year bRFS rate of patients having a PSA bounce of {>=}0.2 was 97.7% vs. 91% for those who did not have a PSA bounce (p = 0.0011). On univariate analysis for biochemical failure, age, risk group, and PSAs per year had a statistically significant correlation with PSA bounce of {>=}0.2 ng/mL. On multivariate analysis, age and PSAs per year remained statistically significant (p < 0.0001 and p = 0.0456, respectively). Conclusions: A bounce definition of a rise {>=}0.2 ng/mL is a reliable definition among several other definitions. The time to first PSA rise is the most valuable factor for distinguishing between a bounce and biochemical failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure statistics for commercial lithium ion batteries: A study of 24 pouch cells

There are relatively few publications that assess capacity decline in enough commercial cells to quantify cell-to-cell variation, but those that do show a surprisingly wide variability. Capacity curves cross each other often, a challenge for efforts to measure the state of health and predict the remaining useful life (RUL) of individual cells. We analyze capacity fade statistics for 24 commercial pouch cells, providing an estimate for the time to 5% failure. Our data indicate that RUL predictions based on remaining capacity or internal resistance are accurate only once the cells have already sorted themselves into “better” and “worse” ones. Analysis of our failure data, using maximum likelihood techniques, provide uniformly good fits for a variety of definitions of failure with normal and with 2- and 3-parameter Weibull probability density functions, but we argue against using a 3-parameter Weibull function for our data. pdf fitting parameters appear to converge after about 15 failures, although business objectives should ultimately determine whether data from a given number of batteries provides sufficient confidence to end lifecycle testing. Increased efforts to make batteries with more consistent lifetimes should lead to improvements in battery cost and safety.

25 ENERGY STORAGE↗