Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Programmable Hyperspectral Imaging Mapper

Programmable hyperspectral imaging mapper (PHIMAP) is conceptual generic advanced spectral imaging system that scans swath along ground track from airplane or spacecraft in orbit. Features include spectrally agile filters and processing on focal-plane array. Provides both high spatial resolution and large number of spectral channels. Can be programmed to trade spectral resolution andspectral coverage flexibly against signal-to-noise ratio to optimize utility of image data from scenes of spectrally and spatially varying brightness.

Cutts, James A.↗

Assessment of Reduced-Kinetics Mechanisms for Combustion of Jet Fuel in CFD Applications

A computational effort was undertaken to analyze the details of fluid flow in Lean-Direct Injection (LDI) combustors for next-generation LDI design. The National Combustor Code (NCC) was used to perform reacting flow computations on single-element LDI injector configurations. The feasibility of using a reduced chemical-kinetics approach, which optimizes the reaction rates and species to model the emissions characteristics typical of lean-burning gas-turbine combustors, was assessed. The assessments were performed with Reynolds- Averaged Navier-Stokes (RANS) and Time-Filtered Navier Stokes (TFNS) time-integration, with a Lagrangian spray model with the NCC code. The NCC predictions for EINOx and combustor exit temperature were compared with experimental data for two different single-element LDI injector configurations, with 60deg and 45deg axially swept swirler vanes. The effects of turbulence-chemistry interaction on the predicted flow in a typical LDI combustor were studied with detailed comparisons of NCC TFNS with experimental data.

Ajmani, Kumud↗

Estimation With Range Depended Sensor Model

This paper focuses on the improvement of object detection accuracy taking into account the sensor’s reading degradation as the relative range increases. The approach is based on the assumption that range measurement error depends on the actual range. Specifically, we model the measurement error as a proportional to the actual range term plus a zero-mean, Gaussian distributed, and uncorrelated process. The tracking problem is considered in a mixed continuous-discrete time domain, where the target dynamics is in continuous-time and the measurements are in discrete-time, which is an optimal choice in many tracking and navigation applications. We adopt a commonly used continuous time coordinate-uncoupled white-noise acceleration model for a point object to describe the target motion, and use Extended Kalman Filter (EKF) framework to estimate the target's state and the unknown proportionality coefficient.

Vahram Stepanyan↗

800MHz Crab Cavity Conceptual Design For the LHC Upgrade

In this paper, we present an 800 MHz crab cavity conceptual design for the LHC upgrade. The cell shape is optimized for lower maximum peak surface fields as well as higher transverse R/Q. A compact coax-to-coax coupler scheme is proposed to damp the LOM/SOM modes. A two-stub antenna with a notch filter is used as the HOM coupler to damp the HOM modes in the horizontal plane and rejects the operating mode at 800MHz. Multipacting (MP) simulations show that there are strong MP particles at the disks. Adding grooves along the short axis without changing the operating mode's RF characteristics can suppress the MP activities. Possible input coupler configurations are discussed.

43 PARTICLE ACCELERATORS↗

Evidence-Based Recommendations for Optimizing Light in Day-to-Day Spaceflight Operations

NASA Behavioral Health and Performance Element (BHP) personnel have previously reported on efforts to transition evidence‐based recommendations for a flexible lighting system on the International Space Station (ISS). Based on these recommendations, beginning in 2016 the ISS will replace the current fluorescent‐based lights with an LED‐based system to optimize visual performance, facilitate circadian alignment, promote sleep, and hasten schedule shifting. Additional efforts related to lighting countermeasures in spaceflight operations have also been underway. As an example, a recent BHP research study led by investigators at Harvard Medical School and Brigham and Women's Hospital, evaluated the acceptability, feasibility, and effectiveness of blue‐enriched light exposure during exercise breaks for flight controllers working the overnight shift in the Mission Control Center (MCC) at NASA Johnson Space Center. This effort, along with published laboratory studies that have demonstrated the effectiveness of appropriately timed light for promoting alertness, served as an impetus for new light options, and educational protocols for flight controllers. In addition, a separate set of guidelines related to the light emitted from electronic devices, were provided to the Astronaut Office this past year. These guidelines were based on an assessment led by NASA's Lighting Environment Test Facility that included measuring the spectral power distribution, irradiance, and radiance of light emitted from ISS‐grade laptops and I‐Pads, as well as Android devices. Evaluations were conducted with and without the use of off‐the‐shelf screen filters as well as a software application that touts minimizing the short‐wave length of the visible light spectrum. This presentation will focus on the transition for operations process related to lighting countermeasures in the MCC, as well as the evidence to support recommendations for optimal use of laptops, I‐Pads, and Android devices during all phases of spaceflight operations.

Whitmire, Alexandra↗

Optimal estimator model for human spatial orientation

A model is being developed to predict pilot dynamic spatial orientation in response to multisensory stimuli. Motion stimuli are first processed by dynamic models of the visual, vestibular, tactile, and proprioceptive sensors. Central nervous system function is then modeled as a steady-state Kalman filter which blends information from the various sensors to form an estimate of spatial orientation. Where necessary, this linear central estimator has been augmented with nonlinear elements to reflect more accurately some highly nonlinear human response characteristics. Computer implementation of the model has shown agreement with several important qualitative characteristics of human spatial orientation, and it is felt that with further modification and additional experimental data the model can be improved and extended. Possible means are described for extending the model to better represent the active pilot with varying skill and work load levels.

Borah, J.↗

Time-resolved measurements of the hot-electron population in ignition-scale experiments on the National Ignition Facility (invited)

In laser-driven inertial confinement fusion, hot electrons can preheat the fuel and prevent fusion-pellet compression to ignition conditions. Measuring the hot-electron population is key to designing an optimized ignition platform. The hot electrons in these high-intensity, laser-driven experiments, created via laser-plasma interactions, can be inferred from the bremsstrahlung generated by hot electrons interacting with the target. At the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 43, 2841 (2004)], the filter-fluorescer x-ray (FFLEX) diagnostic–a multichannel, hard x-ray spectrometer operating in the 20–500 keV range–has been upgraded to provide fully time-resolved, absolute measurements of the bremsstrahlung spectrum with ∼300 ps resolution. Initial time-resolved data exhibited significant background and low signal-to-noise ratio, leading to a redesign of the FFLEX housing and enhanced shielding around the detector. The FFLEX x-ray sensitivity was characterized with an absolutely calibrated, energy-dispersive high-purity germanium detector using the high-energy x-ray source at NSTec Livermore Operations over a range of K-shell fluorescence energies up to 111 keV (U K{sub β}). The detectors impulse response function was measured in situ on NIF short-pulse (∼90 ps) experiments, and in off-line tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MME-based attitude dynamics identification and estimation for SAMPEX

A method is described for obtaining optimal attitude estimation algorithms for spacecraft lacking attitude rate measurement devices (rate gyros), and then demonstrated using actual flight data from the Solar, Anomalous, and Magnetospheric Particle Explorer (SAMPEX) spacecraft. SAMPEX does not have on-board rate sensing, and relies on sun sensors and a three-axis magnetometer for attitude determination. Problems arise since typical attitude estimation is accomplished by filtering measurements of both attitude and attitude rates. Rates are nearly always sampled much more densely than are attitudes. Thus, the absence/loss of rate data normally reduces both the total amount of data available and the sampling density (in time) by a substantial fraction. As a result, the sensitivity of the estimates to model uncertainty and to measurement noise increases. In order to maintain accuracy in the attitude estimates, there is increased need for accurate models of the rotational dynamics. The proposed approach is based on the minimum model error (MME) optimal estimation strategy, which has been successfully applied to estimation of poorly modeled dynamic systems which are relatively sparsely and/or noisily measured. The MME estimates may be used to construct accurate models of the system dynamics (i.e. perform system model identification). Thus, an MME-based approach directly addresses the problems created by absence of attitude rate measurements.

Depena, Juan↗

Using Digital Waveforms to Mitigate Solvent Clustering During Mass Filter Analysis of Proteins

With advances in the precision of digital electronics, waveform generation technology has progressed to a state that enables the creation of m/z filters that are purely digitally driven. These advances present new methods of performing mass analyses that provide information from a chemical system that are inherently difficult to achieve by other means. One notable characteristic of digitally driven mass filters is the capacity to transmit ions at m/z ratios that vastly exceed the capabilities of traditional resonant systems. However, the capacity to probe ion m/z ratios that span multiple orders of magnitudes across multiple orders of magnitude presents a new set of issues requiring a solution. In the present work, when probing multiply charged protein species beyond m/z 2000 using a gentle atmospheric pressure interface, the presence of solvent adducts and poorly resolved multimers can severely degrade spectral fidelity. Increasing energy imparted into a target ion population is one approach minimizing these clusters; however, the use of digital waveform technology provides an alternative that maximizes ion transport efficiency and simultaneously minimizes solvent clustering. In addition to the frequency of the applied waveform, digital manipulation also provides control over the duty cycle of the target waveform. This work examines the conditions and approach leading to optimal digital waveform operation to minimize solvent clustering. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geologic CO 2 sequestration monitoring design: A machine learning and uncertainty quantification based approach

Monitoring is a crucial aspect of geologic carbon dioxide (CO 2 ) sequestration risk management. Effective monitoring is critical to ensure CO 2 is safely and permanently stored throughout the life-cycle of a geologic CO 2 sequestration project. Effective monitoring involves deciding: (i) where is the optimal location to place the monitoring well(s), and (ii) what type of data (pressure, temperature, CO 2 saturation, etc.) should be measured taking into consideration the uncertainties at geologic sequestration sites. We have developed a filtering-based data assimilation procedure to design effective monitoring approaches. To reduce the computational cost of the filtering-based data assimilation process, a machine-learning algorithm: Multivariate Adaptive Regression Splines is used to derive computationally effcient reduced order models from results of full-physics numerical simulations of CO 2 injection in saline aquifer and subsequent multi-phase fluid flow. We use example scenarios of CO 2 leakage through legacy wellbore and demonstrate a monitoring strategy can be selected with the aim of reducing uncertainty in metrics related to CO 2 leakage. We demonstrate the proposed framework with two synthetic examples: a simple validation case and a more complicated case including multiple monitoring wells. The examples demonstrate that the proposed approach can be effective in developing monitoring approaches that take into consideration uncertainties.

58 GEOSCIENCES↗

A constrained, total-variation minimization algorithm for low-intensity x-ray CT

Purpose: The authors developed an iterative image-reconstruction algorithm for application to low-intensity computed tomography projection data, which is based on constrained, total-variation (TV) minimization. The algorithm design focuses on recovering structure on length scales comparable to a detector bin width. Methods: Recovering the resolution on the scale of a detector bin requires that pixel size be much smaller than the bin width. The resulting image array contains many more pixels than data, and this undersampling is overcome with a combination of Fourier upsampling of each projection and the use of constrained, TV minimization, as suggested by compressive sensing. The presented pseudocode for solving constrained, TV minimization is designed to yield an accurate solution to this optimization problem within 100 iterations. Results: The proposed image-reconstruction algorithm is applied to a low-intensity scan of a rabbit with a thin wire to test the resolution. The proposed algorithm is compared to filtered backprojection (FBP). Conclusions: The algorithm may have some advantage over FBP in that the resulting noise level is lowered at equivalent contrast levels of the wire.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-E-09: Respiratory Signal Prediction Based On Multi-Layer Perceptron Neural Network Using Adjustable Training Samples

Purpose: Dynamic tracking of moving organs, such as lung and liver tumors, under radiation therapy requires prediction of organ motions prior to delivery. The shift of moving organ may change a lot due to huge transform of respiration at different periods. This study aims to reduce the influence of that changes using adjustable training signals and multi-layer perceptron neural network (ASMLP). Methods: Respiratory signals obtained using a Real-time Position Management(RPM) device were used for this study. The ASMLP uses two multi-layer perceptron neural networks(MLPs) to infer respiration position alternately and the training sample will be updated with time. Firstly, a Savitzky-Golay finite impulse response smoothing filter was established to smooth the respiratory signal. Secondly, two same MLPs were developed to estimate respiratory position from its previous positions separately. Weights and thresholds were updated to minimize network errors according to Leverberg-Marquart optimization algorithm through backward propagation method. Finally, MLP 1 was used to predict 120∼150s respiration position using 0∼120s training signals. At the same time, MLP 2 was trained using 30∼150s training signals. Then MLP is used to predict 150∼180s training signals according to 30∼150s training signals. The respiration position is predicted as this way until it was finished. Results: In this experiment, the two methods were used to predict 2.5 minute respiratory signals. For predicting 1s ahead of response time, correlation coefficient was improved from 0.8250(MLP method) to 0.8856(ASMLP method). Besides, a 30% improvement of mean absolute error between MLP(0.1798 on average) and ASMLP(0.1267 on average) was achieved. For predicting 2s ahead of response time, correlation coefficient was improved from 0.61415 to 0.7098.Mean absolute error of MLP method(0.3111 on average) was reduced by 35% using ASMLP method(0.2020 on average). Conclusion: The preliminary results demonstrate that the ASMLP respiratory prediction method is more accurate than MLP method and can improve the respiration forecast accuracy.

60 APPLIED LIFE SCIENCES↗

Development of a chemiluminescent and bioluminescent system for the detection of bacteria in wastewater effluent

Automated chemiluminescent and bioluminescent sensors were developed for continuous monitoring of microbial levels in wastewater effluent. Development of the chemiluminescent system included optimization of reagent concentrations as well as two new techniques which will allow for increased sensitivity and specificity. The optimal reagent concentrations are 0.0025 M luminol and 0.0125 M sodium perborate in 0.75N sodium hydroxide before addition of sample. The methods developed to increase specificity include (1) extraction of porphyrins from bacteria collected in a filter using 0.1N NaOH - 50 percent Ethanol, and (2) use of the specific reaction rate characteristics for the different luminol catalysts. Since reaction times are different for each catalyst, the reaction can be made specific for bacteria by measuring only the light emission from the particular reaction time zone specific for bacteria. Developments of the bioluminescent firefly luciferase system were in the area of flow system design.

Thomas, R. R.↗

SU-D-206-06: Task-Specific Optimization of Scintillator Thickness for CMOS-Detector Based Cone-Beam Breast CT

Purpose: To optimize the cesium iodide (CsI:Tl) scintillator thickness in a complimentary metal-oxide semiconductor (CMOS)-based detector for use in dedicated cone-beam breast CT. Methods: The imaging task considered was the detection of a microcalcification cluster comprising six 220µm diameter calcium carbonate spheres, arranged in the form of a regular pentagon with 2 mm spacing on its sides and a central calcification, similar to that in ACR-recommended mammography accreditation phantom, at a mean glandular dose of 4.5 mGy. Generalized parallel-cascades based linear systems analysis was used to determine Fourier-domain image quality metrics in reconstructed object space, from which the detectability index inclusive of anatomical noise was determined for a non-prewhitening numerical observer. For 300 projections over 2π, magnification-associated focal-spot blur, Monte Carlo derived x-ray scatter, K-fluorescent emission and reabsorption within CsI:Tl, CsI:Tl quantum efficiency and optical blur, fiberoptic plate transmission efficiency and blur, CMOS quantum efficiency, pixel aperture function and additive noise, and filtered back-projection to isotropic 105µm voxel pitch with bilinear interpolation were modeled. Imaging geometry of a clinical prototype breast CT system, a 60 kV Cu/Al filtered x-ray spectrum from 0.3 mm focal spot incident on a 14 cm diameter semi-ellipsoidal breast were used to determine the detectability index for 300–600 µm thick (75µm increments) CsI:Tl. The CsI:Tl thickness that maximized the detectability index was considered optimal. Results: The limiting resolution (10% modulation transfer function, MTF) progressively decreased with increasing CsI:Tl thickness. The zero-frequency detective quantum efficiency, DQE(0), in projection space increased with increasing CsI:Tl thickness. The maximum detectability index was achieved with 525µm thick CsI:Tl scintillator. Reduced MTF at mid-to-high frequencies for 600µm thick CsI:Tl lowered the detectability index than 525µm CsI:Tl. Conclusion: For the x-ray spectrum and imaging conditions considered, a 525µm thick CsI:Tl scintillator integrated with the CMOS detector is optimal for detecting microcalcification cluster. Funding support: Supported in part by NIH R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI. Disclosures: SV, GV and AK - Research collaboration, Koning Corp., West Henrietta, NY.

60 APPLIED LIFE SCIENCES↗

Integrated Sensing and Controls for Coal Gasification - Development of Model-Based Controls for GE's Gasifier and Syngas Cooler (Final Technical Report)

This report summarizes the achievements and final results of this program. The objective of this program is to develop a comprehensive systems approach to integrated design of sensing and control systems for an Integrated Gasification Combined Cycle (IGCC) plant, using advanced model-based techniques. In particular, this program is focused on the model-based sensing and control system design for the core gasification section of an IGCC plant. The overall approach consists of (i) developing a first-principles physics-based dynamic model of the gasification section, (ii) performing model-reduction where needed to derive low-order models suitable for controls analysis and design, (iii) developing a sensing system solution combining online sensors with model-based estimation for important process variables not measured directly, and (iv) optimizing the steady-state and transient operation of the plant for normal operation as well as for startup using model predictive controls (MPC). Initially, available process unit models were implemented in a common platform using Matlab/Simulink{reg_sign}, and appropriate model reduction and model updates were performed to obtain the overall gasification section dynamic model. Also, a set of sensor packages were developed through extensive lab testing and implemented in the Tampa Electric Company IGCC plant at Polk power station in 2009, to measure temperature and strain in the radiant syngas cooler (RSC). Plant operation data was also used to validate the overall gasification section model. The overall dynamic model was then used to develop a sensing solution including a set of online sensors coupled with model-based estimation using nonlinear extended Kalman filter (EKF). Its performance in terms of estimating key unmeasured variables like gasifier temperature, carbon conversion, etc., was studied through extensive simulations in the presence sensing errors (noise and bias) and modeling errors (e.g. unknown gasifier kinetics, RSC fouling). In parallel, an MPC solution was initially developed using ideal sensing to optimize the plant operation during startup pre-heating as well as steady state and transient operation under normal high-pressure conditions, e.g. part-load, base-load, load transition and fuel changes. The MPC simulation studies showed significant improvements both for startup pre-heating and for normal operation. Finally, the EKF and MPC solutions were coupled to achieve the integrated sensing and control solution and its performance was studied through extensive steady state and transient simulations in the presence of sensor and modeling errors. The results of each task in the program and overall conclusions are summarized in this final report.

01 COAL, LIGNITE, AND PEAT↗

Final Report, DOE Early Career Award: Predictive modeling of complex physical systems: new tools for statistical inference, uncertainty quantification, and experimental design

Predictive simulation of complex physical systems increasingly rests on the interplay of experimental observations with computational models. Key inputs, parameters, or structural aspects of models may be incomplete or unknown, and must be developed from indirect and limited observations. At the same time, quantified uncertainties are needed to qualify computational predictions in the support of design and decision-making. In this context, Bayesian statistics provides a foundation for inference from noisy and limited data, but at prohibitive computional expense. This project intends to make rigorous predictive modeling *feasible* in complex physical systems, via accelerated and scalable tools for uncertainty quantification, Bayesian inference, and experimental design. Specific objectives are as follows: 1. Develop adaptive posterior approximations and dimensionality reduction approaches for Bayesian inference in high-dimensional nonlinear systems. 2. Extend accelerated Bayesian methodologies to large-scale {\em sequential} data assimilation, fully treating nonlinear models and non-Gaussian state and parameter distributions. 3. Devise efficient surrogate-based methods for Bayesian model selection and the learning of model structure. 4. Develop scalable simulation/optimization approaches to nonlinear Bayesian experimental design, for both parameter inference and model selection. 5. Demonstrate these inferential tools on chemical kinetic models in reacting flow, constructing and refining thermochemical and electrochemical models from limited data. Demonstrate Bayesian filtering on canonical stochastic PDEs and in the dynamic estimation of inhomogeneous subsurface properties and flow fields.

97 MATHEMATICS AND COMPUTING↗

Underlying Fundamentals of Kalman Filtering for River Network Modeling

The grand challenge of producing hydrometeorological estimates every time and everywhere has motivated the fusion of sparse observations with dense numerical models, with a particular interest on discharge in river modeling. Ensemble methods are largely preferred as they enable the estimation of error properties, but at the expense of computational load and generally with underestimations. These imperfect stochastic estimates motivate the use of correction methods, that is, error localization and inflation, although the physical justifications for their optimality are limited. The purpose of this study is to use one of the simplest forms of data assimilation when applied to river modeling and reveal the underlying mechanisms impacting its performance. Our framework based on assimilating daily averaged in situ discharge measurements to correct daily averaged runoff was tested over a 4-yr case study of two rivers in Texas. Results show that under optimal conditions of inflation and localization, discharge simulations are consistently improved such that the mean values of Nash–Sutcliffe efficiency are enhanced from211.32 to 0.55 at observed gauges and from212.24 to21.10 at validation gauges. Yet, parameters controlling the inflation and the localization have a large impact on the performance. Further investigations of these sensitivities showed that optimal inflation occurs when compensating exactly for discrepancies in the magnitude of errors while optimal localization matches the distance traveled during one assimilation window. These results may be applicable to more advanced data assimilation methods as well as for larger applications motivated by upcoming river-observing satellite missions, such as NASA’s Surface Water and Ocean Topography mission.

Streamflow↗