Search NASA⌕ Search

SEARCH · Search NASA

Results for “high availability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Ab initio adiabatic and quasidiabatic potential energy surfaces of lowest four electronic states of the H{sup +}+O{sub 2} system

Ab initio global adiabatic and quasidiabatic potential energy surfaces of lowest four electronic (1-4 {sup 3}A{sup ''}) states of the H{sup +}+O{sub 2} system have been computed in the Jacobi coordinates (R,r,{gamma}) using Dunning's cc-pVTZ basis set at the internally contracted multireference (single and double) configuration interaction level of accuracy, which are relevant to the dynamics studies of inelastic vibrational and charge transfer processes observed in the scattering experiments. The computed equilibrium geometry parameters of the bound [HO{sub 2}]{sup +} ion in the ground electronic state and other parameters for the transition state for the isomerization process, HOO{sup +}<-->OOH{sup +} are in good quantitative agreement with those available from the high level ab initio calculations, thus lending credence to the accuracy of the potential energy surfaces. The nonadiabatic couplings between the electronic states have been analyzed in both the adiabatic and quasidiabatic frameworks by computing the nonadiabatic coupling matrix elements and the coupling potentials, respectively. It is inferred that the dynamics of energy transfer processes in the scattering experiments carried out in the range of 9.5-23 eV would involve all the four electronic states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Present and Future X-ray Tomographic Microscopy at TOMCAT

During its first four years of life, the TOMCAT beamline at the Swiss Light Source has established itself as a state-of-the art hard x-ray tomographic microscopy endstation for experiments on a large variety of samples, ranging from the fields of biology to materials science. It routinely performs absorption as well as phase-contrast imaging with an isotropic voxel size ranging from 0.360 up to 14.8 microns. Phase contrast is obtained either with simple edge-enhancement, a modified transport of intensity approach or grating interferometry. Typical acquisition times are on the order of a few minutes, depending on energy and resolution. A recently implemented automatic sample exchanger is now available for high-throughput studies. In addition to further developments in phase-contrast imaging, current scientific activities at the beamline focus on pushing spatial and temporal resolution by a few orders of magnitude, aiming at nano- and 'real-time' tomography.

43 PARTICLE ACCELERATORS↗

Phase Contrast Imaging with Coded Apertures Using Laboratory-Based X-ray Sources

X-ray phase contrast imaging is a powerful technique that allows detection of changes in the phase of x-ray wavefronts as they pass through a sample. As a result, details not visible in conventional x-ray absorption imaging can be detected. Until recently the majority of applications of phase contrast imaging were at synchrotron facilities due to the availability of their high flux and coherence; however, a number of techniques have appeared recently that allow phase contrast imaging to be performed using laboratory sources. Here we describe a phase contrast imaging technique, developed at University College London, that uses two coded apertures. The x-ray beam is shaped by the pre-sample aperture, and small deviations in the x-ray propagation direction are detected with the help of the detector aperture. In contrast with other methods, it has a much more relaxed requirement for the source size (it works with source sizes up to 100 {mu}m). A working prototype coded-aperture system has been built. An x-ray detector with directly deposited columnar CsI has been used to minimize signal spill-over into neighboring pixels. Phase contrast images obtained with the system have demonstrated its effectiveness for imaging low-absorption materials.

07 ISOTOPE AND RADIATION SOURCES↗

Electron beam coupling to a metamaterial structure

Microwave metamaterials have shown promise in numerous applications, ranging from strip lines and antennas to metamaterial-based electron beam driven devices. In general, metamaterials allow microwave designers to obtain electromagnetic characteristics not typically available in nature. High Power Microwave (HPM) sources have in the past drawn inspiration from work done in the conventional microwave source community. In this article, the use of metamaterials in an HPM application is considered by using an effective medium model to determine the coupling of an electron beam to a metamaterial structure in a geometry similar to that of a dielectric Cerenkov maser. Use of the effective medium model allows for the analysis of a wide range of parameter space, including the “mu-negative,”“epsilon-negative,” and “double negative” regimes of the metamaterial. The physics of such a system are modeled analytically and by utilizing the particle-in-cell code ICEPIC. For this geometry and effective medium representation, optimum coupling of the electron beam to the metamaterial, and thus the optimum microwave or RF production, occurs in the epsilon negative regime of the metamaterial. Given that HPM tubes have been proposed that utilize a metamaterial, this model provides a rapid method of characterizing a source geometry that can be used to quickly understand the basic physics of such an HPM device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress and present status of ITER cryoline system

The cryoline system at ITER forms a very complex network localized inside the Tokamak building, on a dedicated plant bridge and in cryoplant areas. The cooling power produced in the cryoplant is distributed via these lines with a total length of about 3.7 km and interconnecting all the cold boxes of the cryogenic system as well as the cold boxes of various clients (magnets, cryopumps and thermal shield). Distinct layouts and polygonal geometry, nuclear safety and confinement requirements, difficult installation and in-service inspection/repair demand very high reliability and availability for the cryolines. The finalization of the building-embedded plates for supporting the lines, before the detailed design, has made this project technologically more challenging. The conceptual design phase has been completed and procurement arrangements have been signed with India, responsible for providing the system of cryolines and warm lines to ITER, as in kind contribution. The prototype test for the design and performance validation has been planned on a representative cryoline section. After describing the basic features and general layout of the ITER cryolines, the paper presents key design requirements, conceptual design approach, progress and status of the cryolines project as well as challenges to build such a complex cryoline system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A laser application to nuclear astrophysics

In the last decade, the availability in high-intensity laser beams capable of producing plasmas with ion energies large enough to induce nuclear reactions has opened new research paths in nuclear physics. We studied the reactions {sup 3}He(d,p){sup 4}He and d(d,n){sup 3}He at temperatures of few keV in a plasma, generated by the interaction of intense ultrafast laser pulses with molecular deuterium or deuterated-methane clusters mixed with {sup 3}He atoms. The yield of 14.7 MeV protons from the {sup 3}He(d,p){sup 4}He reaction was used to extract the astrophysical S factor. Results of the experiment performed at the Center for High Energy Density Science at The University of Texas at Austin will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A microfluidic flow-cell for the study of the ultrafast dynamics of biological systems

The study of biochemical dynamics by ultrafast spectroscopic methods is often restricted by the limited amount of liquid sample available, while the high repetition rate of light sources can induce photodamage. In order to overcome these limitations, we designed a high flux, sub-ml, capillary flow-cell. While the 0.1 mm thin window of the 0.5 mm cross-section capillary ensures an optimal temporal resolution and a steady beam deviation, the cell-pump generates flows up to ~0.35 ml/s that are suitable to pump laser repetition rates up to ~14 kHz, assuming a focal spot-diameter of 100 μm. In addition, a decantation chamber efficiently removes bubbles and allows, via septum, for the addition of chemicals while preserving the closed atmosphere. The minimal useable amount of sample is ~250 μl.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modification of the structural and magnetic properties of granular FePt films by seed layer conditioning

The steadily increasing amount of digital information necessitates the availability of reliable high capacity magnetic data storage. Here, future hard disk drives with extended areal storage densities beyond 1.0 Tb/in{sup 2} are envisioned by using high anisotropy granular and chemically L1{sub 0}-ordered FePt (002) perpendicular media within a heat-assisted magnetic recording scheme. Perpendicular texturing of the [001] easy axes of the individual grains can be achieved by using MgO seed layers. It is therefore investigated, if and how an Ar{sup +} ion irradiation of the MgO seed layer prior to the deposition of the magnetic material influences the MgO surface properties and hereby the FePt [001] texture. Structural investigations reveal a flattening of the seed layer surface accompanied by a change in the morphology of the FePt grains. Moreover, the fraction of small second layer particles and the degree of coalescence of the primarily deposited FePt grains strongly increases. As for the magnetic performance, this results in a reduced coercivity along the magnetic easy axis (out of plane) and in enhanced hard axis (in-plane) remanence values. The irradiation induced changes in the magnetic properties of the granular FePt-C films are traced back to the accordingly modified atomic structure of the FePt-MgO interface region.

36 MATERIALS SCIENCE↗

Simulation study of 3–5 keV x-ray conversion efficiency from Ar K-shell vs. Ag L-shell targets on the National Ignition Facility laser

Tailored, high-flux, multi-keV x-ray sources are desirable for studying x-ray interactions with matter for various civilian, space and military applications. For this study, we focus on designing an efficient laser-driven non-local thermodynamic equilibrium 3–5 keV x-ray source from photon-energy-matched Ar K-shell and Ag L-shell targets at sub-critical densities (∼n{sub c}/10) to ensure supersonic, volumetric laser heating with minimal losses to kinetic energy, thermal x rays and laser-plasma instabilities. Using HYDRA, a multi-dimensional, arbitrary Lagrangian-Eulerian, radiation-hydrodynamics code, we performed a parameter study by varying initial target density and laser parameters for each material using conditions readily achievable on the National Ignition Facility (NIF) laser. We employ a model, benchmarked against Kr data collected on the NIF, that uses flux-limited Lee-More thermal conductivity and multi-group implicit Monte-Carlo photonics with non-local thermodynamic equilibrium, detailed super-configuration accounting opacities from CRETIN, an atomic-kinetics code. While the highest power laser configurations produced the largest x-ray yields, we report that the peak simulated laser to 3–5 keV x-ray conversion efficiencies of 17.7% and 36.4% for Ar and Ag, respectively, occurred at lower powers between ∼100–150 TW. For identical initial target densities and laser illumination, the Ag L-shell is observed to have ≳10× higher emissivity per ion per deposited laser energy than the Ar K-shell. Although such low-density Ag targets have not yet been demonstrated, simulations of targets fabricated using atomic layer deposition of Ag on silica aerogels (∼20% by atomic fraction) suggest similar performance to atomically pure metal foams and that either fabrication technique may be worth pursuing for an efficient 3–5 keV x-ray source on NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GaAs x-ray detectors with sub-nanosecond temporal response

Fast semiconductor radiation detectors operated in current mode provide a valuable diagnostic in pulsed power applications. Si detectors are common due to the availability of high-quality materials and mature fabrication processes, but they offer low absorption for hard x-rays above ∼10 keV. GaAs can provide increased hard x-ray absorption for the same detector volume due to a higher atomic number. GaAs photodiodes have been produced from epitaxial material grown at Sandia National Laboratories and fabricated at Sandia’s microfabrication facility. These detectors have significantly higher hard x-ray absorption (>10× at 15 keV) and nearly identical temporal impulse response to similarly sized Si detectors of 0.5 ns full-width half maximum.

Looker, Quinn (ORCID:0000000325820630)↗

Lasing Below 170 nm Using an Oscillator FEL

The short wavelength operation of free-electron laser (FEL) oscillators is limited by the availability of high-reflectivity, thermally stable, and radiation-resistant FEL mirrors in the VUV wavelength. We report our recent work to extend the shortest lasing wavelength of the oscillator FEL to 168.6 nm using a storage ring FEL. This progress has been made possible by developing a new FEL configuration with substantially reduced undulator harmonic radiation on the FEL mirror, a thermally stable FEL optical cavity, and a new type of high-reflectivity fluoride-based multilayer coating with a protective capping layer. Using these fluoride-based mirrors, we have demonstrated storage ring FEL lasing from 168.6 to 179.7 nm with excellent beam stability. Employing this VUV FEL in Compton scattering, we have produced the first 120 MeV gamma rays at the High Intensity Gamma-ray Source (HIGS). Furthermore, operating the HIGS in this new high-energy region will create many new opportunities for photonuclear physics research, in particular, the low-energy QCD research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstruction of magnetic island electron temperature in mixed second and third harmonic electron cyclotron emission conditions

Here we develop a method to use the mixed third and second harmonic electron cyclotron emission (ECE) signal in the DIII-D tokamak to reconstruct the electron temperature profile of a rotating magnetic island. The third harmonic ECE is removed by extracting the rotating-island-associated fluctuations in the mixed signal, and the extracted fluctuation is combined with the equilibrium temperature obtained from other diagnostics after correcting for the third harmonic reabsorption. The accuracy of the reconstruction is studied by considering a DIII-D shot where an unmixed signal from an island is available on the low field side of the plasma and a mixed signal from the same island is available from the high field side. It is found that the reconstruction method successfully reproduces the island shape and temperature perturbation magnitude without the distortion caused by third harmonic ECE mixing. However, the radial location of the reconstructed island is somewhat displaced relative to the location of the q = 2 surface in the axisymmetric equilibrium reconstruction, resulting in a corresponding inaccuracy in the absolute temperature of the island. It is conjectured that this may arise from an inaccuracy of the reconstructed axisymmetric equilibrium in this region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wind plant wake losses: Disconnect between turbine actuation and control of plant wakes with engineering wake models

Wake losses from neighboring plants may become a major factor in wind plant design and control as additional plants are constructed in areas with high wind resource availability. Because plant wakes span a large range of physical scales, from turbine rotor diameter to tens of kilometers, it is unclear whether conventional wake models or turbine control strategies are effective at the plant scale. Wake steering and axial induction control are evaluated in the current work as means of reducing the impact of neighboring wind plants on power and levelized cost of electricity. FLOw Redirection and Induction in Steady State (FLORIS) simulations were performed with the Gauss–Curl Hybrid and TurbOPark wake models as well as two operation and maintenance models to investigate control setpoint sensitivity to wake representation and economic factors. Both wake models estimate losses across a range of atmospheric conditions, although the wake loss magnitude is dependent on the wake model. Annual energy production and levelized cost of electricity are driven by wind direction frequency, with frequently aligned plants experiencing the greatest losses. However, both wake steering and axial induction are unable to mitigate the impact of upstream plants. Wake steering is constrained by plant geometry, since wake displacement is much less than the plant wake width, while axial induction requires curtailing the majority of turbines in upstream plants. Individual turbine strategies are limited by their effective scale and model representation. New wake models that include plant-scale physics are needed to facilitate the design of effective plant wake control strategies.

Scott, Ryan (ORCID:0000000328107574)↗

Primary Heat Transport System Design Considerations for Xcimer Energy’s Athena Fusion Pilot Plant

Fusion energy promises a reliable, carbon-free source of power; however, significant challenges remain before it can be deployed as an economical energy source. In addition to achieving fusion conditions, power plants must operate under extreme temperatures, radiation, and mechanical loads while maintaining high efficiency and availability. These requirements place strong demands on engineering design and plant operation. This work focuses on the engineering challenges associated with balance of plant analysis for inertial fusion energy systems. In particular, this paper examines the design considerations for primary heat transfer systems in fusion pilot plants employing molten fluoride salt coolants, with particular emphasis on system layout optimization and the balance between competing design objectives using the Xcimer Energy Athena inertial pilot plant design as a case study. Through systematic analysis of candidate system configurations and parametric sensitivity studies, we identify key engineering trade-offs governing salt inventory, pumping power requirements, and operational flexibility. The analysis employs system-level modeling tools to explore the design space and establish relationships between geometric parameters and system performance metrics.

Greenwood, Scott [ORNL] (ORCID:0000000333480736)↗

M31 GLOBULAR CLUSTER STRUCTURES AND THE PRESENCE OF X-RAY BINARIES

The Andromeda galaxy, M31, has several times the number of globular clusters found in the Milky Way. It contains a correspondingly larger number of low-mass X-ray binaries (LMXBs) associated with globular clusters, and as such can be used to investigate the cluster properties that lead to X-ray binary formation. The best tracer of the spatial structure of M31 globulars is the high-resolution imaging available from the Hubble Space Telescope (HST), and we have used HST data to derive structural parameters for 29 LMXB-hosting M31 globular clusters. These measurements are combined with structural parameters from the literature for a total of 41 (of 50 known) LMXB clusters and a comparison sample of 65 non-LMXB clusters. Structural parameters measured in blue bandpasses are found to be slightly different (smaller core radii and higher concentrations) than those measured in red bandpasses; this difference is enhanced in LMXB clusters and could be related to stellar population differences. Clusters with LMXBs show higher collision rates for their mass compared to clusters without LMXBs, and collision rates estimated at the core radius show larger offsets than rates estimated at the half-light radius. These results are consistent with the dynamical formation scenario for LMXBs. A logistic regression analysis finds that, as expected, the probability of a cluster hosting an LMXB increases with increasing collision rate and proximity to the galaxy center. The same analysis finds that probability of a cluster hosting an LMXB decreases with increasing cluster mass at a fixed collision rate, although we caution that this could be due to sample selection effects. Metallicity is found to be a less important predictor of LMXB probability than collision rate, mass, or distance, even though LMXB clusters have a higher metallicity on average. This may be due to the interaction of location and metallicity: a sample of M31 LMXBs with a greater range in galactocentric distance would likely contain more metal-poor clusters and make it possible to disentangle the two effects.

79 ASTRONOMY AND ASTROPHYSICS↗

MODELING OF THE HERMES SUBMILLIMETER SOURCE LENSED BY A DARK MATTER DOMINATED FOREGROUND GROUP OF GALAXIES

We present the results of a gravitational lensing analysis of the bright z{sub s} = 2.957 submillimeter galaxy (SMG) HERMES found in the Herschel/SPIRE science demonstration phase data from the Herschel Multi-tiered Extragalactic Survey (HerMES) project. The high-resolution imaging available in optical and near-IR channels, along with CO emission obtained with the Plateau de Bure Interferometer, allows us to precisely estimate the intrinsic source extension and hence estimate the total lensing magnification to be {mu} = 10.9 {+-} 0.7. We measure the half-light radius R{sub eff} of the source in the rest-frame near-UV and V bands that characterize the unobscured light coming from stars and find R{sub eff,*} = [2.0 {+-} 0.1] kpc, in good agreement with recent studies on the SMG population. This lens model is also used to estimate the size of the gas distribution (R{sub eff,gas} = [1.1 {+-} 0.5] kpc) by mapping back in the source plane the CO (J = 5 {yields} 4) transition line emission. The lens modeling yields a relatively large Einstein radius R{sub Ein} = 4.''10 {+-} 0.''02, corresponding to a deflector velocity dispersion of [483 {+-} 16] km s{sup -1}. This shows that HERMES is lensed by a galaxy group-size dark matter halo at redshift z{sub l} {approx} 0.6. The projected dark matter contribution largely dominates the mass budget within the Einstein radius with f{sub dm}(< R{sub Ein}) {approx} 80%. This fraction reduces to f{sub dm}(< R{sub eff,G1} {approx_equal} 4.5 kpc) {approx} 47% within the effective radius of the main deflecting galaxy of stellar mass M{sub *,G1} = [8.5 {+-} 1.6] x 10{sup 11} M{sub sun}. At this smaller scale the dark matter fraction is consistent with results already found for massive lensing ellipticals at z {approx} 0.2 from the Sloan Lens ACS Survey.

79 ASTRONOMY AND ASTROPHYSICS↗