Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Reactive jet and cyclonic attrition analysis of ilmenite in chemical looping combustion systems

In chemical looping combustion (CLC), the chosen oxygen carrier’s (OC) reactivity maintenance and attrition propensity play key roles in determining its lifetime in such systems. Jet and cyclonic attrition are two main mechanisms of attrition in CLC systems, which typically use fluidized beds and cyclones. In contrast to standardized tests, that assess attrition characteristics under ambient and non-reacting conditions, a realistic evaluation must include the behavior under relevant high temperatures and cyclic oxidation-reduction. In this study, separate jet and cyclonic attrition test units were constructed to investigate the effects of temperature, fuel gas concentration and velocity on the performance of ilmenite, a natural ore-based OC in CLC. Testing showed that thermal and chemical effects were crucial to accurately determine the performance of ilmenite. For experiments conducted between 820°C and 970°C, the intermediate temperature of 895°C provided the best balance between high reactivity and material durability. Additionally, fuel gas concentration affected particle morphology evolution. Iron migration to the surface of the ilmenite particle was enhanced at higher fuel gas concentrations and resulted in reduced attrition rate, presumably due to sintering of the more highly reduced enriched iron phase on the particle surface. The laboratory jet and cyclonic attrition evaluation test units tested in this study can be used to investigate multiple parameters relevant for OC performance, including the degree of reduction, oxygen carrying capacity, attrition resistance, agglomeration, and optimum material operability conditions, as well as to extrapolate test data to determine OC replacement costs in a commercial CLC system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensor Network Demonstration for In Situ Decommissioning - 13332

Florida International University's (FIU's) Applied Research Center is currently supporting the Department of Energy's (DOE) Environmental Management Office of D and D and Facility Engineering program. FIU is supporting DOE's initiative to improve safety, reduce technical risks, and limit uncertainty within D and D operations by identifying technologies suitable to meet specific facility D and D requirements, assessing the readiness of those technologies for field deployment, and conducting feasibility studies and large scale demonstrations of promising technologies. During FY11, FIU collaborated with Savannah River National Laboratory in the development of an experimental test site for the demonstration of multiple sensor systems for potential use in the in situ decommissioning process. In situ decommissioning is a process in which the above ground portion of a facility is dismantled and removed, and the underground portion is filled with a cementious material such as grout. In such a scenario, the question remains on how to effectively monitor the structural health of the grout (cracking, flexing, and sinking), as well as track possible migration of contaminants within and out of the grouted monolith. The right types of sensors can aid personnel in better understanding the conditions within the entombed structure. Without sensors embedded in and around the monolith, it will be very difficult to estimate structural integrity and contaminant transport. Yet, to fully utilize the appropriate sensors and the provided data, their performance and reliability must be evaluated outside a laboratory setting. To this end, a large scale experimental setup and demonstration was conducted at FIU. In order to evaluate a large suite of sensor systems, FIU personnel designed and purchased a pre-cast concrete open-top cube, which served as a mock-up of an in situ DOE decommissioned facility. The inside of the cube measures 10 ft x 10 ft x 8 ft. In order to ensure that the individual sensors would be immobilized during the grout pouring activities, a set of nine sensor racks were designed. The 270 sensors provided by Idaho National Laboratory (INL), Mississippi State University (MSU), University of Houston (UH), and University of South Carolina (USC) were secured to these racks based on predetermined locations. Once sensor racks were installed inside the test cube, connected and debugged, approximately 32 cubic yards of special grout material was used to entomb the sensors. MSU provided and demonstrated four types of fiber loop ring-down (FLR) sensors for detection of water, temperature, cracks, and movement of fluids. INL provided and demonstrated time differenced 3D electrical resistivity tomography (ERT), advanced tensiometers for moisture content, and thermocouples for temperature measurements. University of Houston provided smart aggregate (SA) sensors, which detect crack severity and water presence. An additional UH sensor system demonstrated was a Fiber Bragg Grating (FBG) fiber optic system measuring strain, presence of water, and temperature. USC provided a system which measured acoustic emissions during cracking, as well as temperature and pH sensors. All systems were connected to a Sensor Remote Access System (SRAS) data networking and collection system designed, developed and provided by FIU. The purpose of SRAS was to collect and allow download of the raw sensor data from all the sensor system, as well as allow upload of the processed data and any analysis reports and graphs. All this information was made available to the research teams via the Deactivation and Decommissioning Knowledge Management and Information Tool (D and D KM-IT). As a current research effort, FIU is performing an energy analysis, and transferring several sensor systems to a Photovoltaic (PV) System to continuously monitor energy consumption parameters and overall power demands. Also, One final component of this research is focusing on developing an integrated data network to capture, log and analyze sensor system data in near real time from a single interface. FIU personnel and DOE Fellows monitored the progress and condition of the sensors for a period of six months. During this time, the sensors recorded data pertaining to strain, compression, temperature, crack detection, moisture presence, fluid mobility, shock resistance, monolith movement, and electrical resistivity. In addition, FIU regularly observed the curing process of the grout and documented the cube condition via the nine racks of sensors. The sensors held up throughout the curing process, withstood the natural elements for six months, and monitored the integrity of the grout. The large scale experiment and demonstration conducted at FIU was the first of its kind to demonstrate the feasibility of state of the art sensors for in situ decommissioning applications. These efforts successfully measured the durability, performance, and precision of the sensors in question as well as monitored and recorded the curing process of the selected grout material under natural environmental conditions. The current energy analysis work is resulting in data on the constraints placed by some of the sensor systems on a power network that requires high reliability and low losses. In addition, a sensor system demonstration has determined that it is feasible to develop an integrated data network where data can be accessed in near real-time from all systems, thereby allowing for larger-scale integrated system testing to be performed. Information collected during the execution of this research project will aid decision makers in the identification of sensors to be used in nuclear facilities selected for in situ decommissioning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phenotypic effects of changes in the FTVTxK region of an Arabidopsis secondary wall cellulose synthase compared with results from analogous mutations in other isoforms

Abstract Understanding protein structure and function relationships in cellulose synthase (CesA), including divergent isomers, is an important goal. Here, we report results from mutant complementation assays that tested the ability of sequence variants of AtCesA7, a secondary wall CesA of Arabidopsis thaliana , to rescue the collapsed vessels, short stems, and low cellulose content of the irx3‐1 AtCesA7 null mutant. We tested a catalytic null mutation and seven missense or small domain changes in and near the AtCesA7 FTVTSK motif, which lies near the catalytic domain and may, analogously to bacterial CesA, exist within a substrate “gating loop.” A low‐to‐high gradient of rescue occurred, and even inactive AtCesA7 had a small positive effect on stem cellulose content but not stem elongation. Overall, secondary wall cellulose content and stem length were moderately correlated, but the results were consistent with threshold amounts of cellulose supporting particular developmental processes. Vibrational sum frequency generation microscopy allowed tissue‐specific analysis of cellulose content in stem xylem and interfascicular fibers, revealing subtle differences between selected genotypes that correlated with the extent of rescue of the collapsing xylem phenotype. Similar tests on PpCesA5 from the moss Physcomitrium (formerly Physcomitrella ) patens helped us to synergize the AtCesA7 results with prior results on AtCesA1 and PpCesA5. The cumulative results show that the FTVTxK region is important for the function of an angiosperm secondary wall CesA as well as widely divergent primary wall CesAs, while differences in complementation results between isomers may reflect functional differences that can be explored in further work.

Burris, Jason N.↗

FY19 Transient Prescriptions in TREAT Full-Slotted Core

The transient reactor test facility (TREAT) is a graphite-based transient test reactor at the Idaho National Laboratory. TREAT started operation in 1959 and performed thousands of transient irradiations for the primary purpose of nuclear fuel safety research. TREAT operations were suspended in 1994 and then, several years later, resumed reactor operations in 2017 to support development of advanced nuclear fuels. During TREAT’s first era of operation the transient rod drive system and eventual Automatic Reactor Control System (ARCS) were upgraded and improved to create a transient reactor capable of unparalleled power shaping capabilities. TREAT’s first year of modern experiment work was performed in 2018 and saw the demonstration of new kinds of transients focused on modern experiment needs; especially focused on light water reactor (LWR) category transients including reactivity-initiated accidents (RIA) and loss of coolant accidents (LOCA). These transients were performed using a non-fueled neutronic mockup of a historical sodium loop which was not a perfect representation of future core configurations, but was adequate for demonstrating capabilities, successfully troubleshooting transient programming parameters, and calibrating nuclear models of the core. These physics tests were termed “transient prescription tests”. Later in 2018 the core was reconfigured to a modern fueled experiment arrangement and TREAT began performing irradiations on LWR rodlets where crucial fuel specimen nuclear heating data were obtained, and several supporting systems were commissioned. This successful effort gave way to additional fueled experiments which were performed throughout 2019.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Deployment of salt sample extraction system at an engineering-scale electrorefiner

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness of sampling-based accountancy measurements. Two technologies under development in support of this goal are a vacuum sampling loop module and a high-throughput pneumatic sample generator module. Compared to traditional point sampling approaches (i.e., dip probes), the vacuum sampling loop facilitates the collection of a larger cross-section of the bulk salt in order to collect more representative samples. The vacuum sampling approach also eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. The pneumatic sample generator module is used to facilitate high-throughput sample analysis to improve the measurement precision of any given analytical technique by averaging out random sampling and measurement errors. In FY21, two methods for integrating these two modules were tested including direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampling loop and pneumatic sample generator modules, respectively. While the charging mechanism will be deployed in FY22, the discharge mechanism was tested in FY21 and is described here. The solid salt tube transfer method was deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The approach was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. To discharge salt from the sample tubes at the sampler generator, tube segments were inserted directly into the sample generator’s Helmholtz chamber and pressure pulse actuations were used to generate precision molten salt samples directly from the tube segments. The direct insertion of sample tubes into the sample generator enabled rapid loading of the salt and prevented salt from contacting most of the interior surfaces of the sample generator, which eliminated cross-contamination between runs. The vacuum sampling-loop tube charging mechanism will support high-throughput tube sampling operations by employing a dynamic vacuum filling process to fill short charge tubes that are configured to be rapidly connected and disconnected from the loop. The dynamic vacuum sampling operation will be automated, and sample tube handling can be executed with simple overhead actuation. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques which will enable significant reductions in the time delay for sampling-based high-precision accountancy measurements.

42 ENGINEERING↗

Coal Direct Chemical Looping Retrofit to Pulverized Coal Power Plants for In-Situ CO2 Capture

A novel Coal Direct Chemical Looping (CDCL) system is proposed to effectively capture CO2 from existing PC power plants. The work during the past three years has led to an oxygen carrier particle with satisfactory performance. Moreover, successful laboratory, bench scale, and integrated demonstrations have been performed. The proposed project further advanced the novel CDCL technology to sub-pilot scale (25 kWth). To be more specific, the following objectives attained in the proposed project are: 1. to further improve the oxygen carrying capacity as well as the sulfur/ash tolerance of the current (working) particle; 2. to demonstrate continuous CDCL operations in an integrated mode with > 99% coal (bituminous, subbituminous, and lignite) conversion as well as the production of high temperature exhaust gas stream that is suitable for steam generation in existing PC boilers; 3. to identify, via demonstrations, the fate of sulfur and NOx; 4. to conduct thorough techno-economic analysis that validates the technical and economical attractiveness of the CDCL system. The objectives outlined above were achieved through collaborative efforts among all the participants. CONSOL Energy Inc. performed the techno-economic analysis of the CDCL process. Shell/CRI was able to perform feasibility and economic studies on the large scale particle synthesis and provide composite particles for the sub-pilot scale testing. The experience of B&W (with boilers) and Air Products (with handling gases) assisted the retrofit system design as well as the demonstration unit operations. The experience gained from the sub-pilot scale demonstration of the Syngas Chemical Looping (SCL) process at OSU was able to ensure the successful handling of the solids. Phase 1 focused on studies to improve the current particle to better suit the CDCL operations. The optimum operating conditions for the reducer reactor such as the temperature, char gasification enhancer type, and flow rate were identified. The modifications of the existing bench scale reactor were completed in order to use it in the next phase of the project. In Phase II, the optimum looping medium was selected, and bench scale demonstrations were completed using them. Different types of coal char such as those obtained from bituminous, subbituminous, and lignite were tested. Modifications were made on the existing sub-pilot scale unit for coal injection. Phase III focused on integrated CDCL demonstration in the sub-pilot scale unit. A comprehensive ASPEN® simulations and economic analysis was completed by CONSOL t is expected that the CDCL process will be ready for further demonstrations in a scale up unit upon completion of the proposed project.

Zeng, Liang↗

Genuine SUSY signatures from ug{yields}d-tilde{chi}-tilde{sub i}{sup +} and ug{yields}dW{sup +}, at high energies

We analyze the quark-gluon induced process ug{yields}d-tilde{chi}-tilde{sub i}{sup +}, including the one-loop electroweak effects in the minimal supersymmetric model. This process is dominated by d-tilde{sub L}-production and is determined by four helicity amplitudes, three of which are violating helicity conservation, and another one which respects it and is logarithmically enhanced at high energy. Combining this ug{yields}d-tilde{sub L}{chi}-tilde{sub i}{sup +} analysis with a corresponding one for ug{yields}dW{sup +}, we obtain simple approximate relations between the two processes, testing the minimal supersymmetric model structure at the amplitude and the cross section levels. These relations become exact at asymptotic energies and, provided the supersymmetry (SUSY) scale is not too heavy, they may be approximately correct at LHC energies also. In addition to these, we study the one-loop electroweak corrections to the inclusive d-tilde{chi}-tilde{sub i}{sup +} production at LHC, presenting as examples, the p{sub T} and angular distributions. Comparing these to the corresponding predictions for W+jet production derived earlier, provides an accurate test of the supersymmetric assignments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-243: Design of a Novel Testing Port for Radiation Protection and Shielding Measurements

Purpose: The majority of radiation shielding research utilizes Monte Carlo simulation because of the difficulty in eliminating secondary radiations from measurements. We have designed a test port into a primary barrier of our newest vault to allow for shielding measurements while ensuring adequate protection to the public and staff during normal machine operation. This port allows for measurement of attenuation values of shielding materials, differential dose albedos, and radiation scatter fractions. Methods: The vault design utilized the maze as part of a compound primary barrier. The test port is contained within the maze and is centered along isocenter. The inner 30 cm has a 20×20 cm{sup 2} opening, while the remaining length has a 30×30 cm{sup 2} opening. The block that contains the port has a density of 200 pcf to minimize internal scatter. The 30×30 cm{sup 2} opening is occupied by removable 215 pcf concrete blocks. The innermost and outermost blocks activate an interlock wired into the beam-enable loop. This disallows beam-on in treatment mode if the interlock isn’t closed. The interlock can be overridden in service mode, or by-passed via an override switch in case of circuit failure. Results: The test port was installed in August. The beam is disabled when the interlock is tripped. Measurements taken when the primary beam is not incident on the port are indistinguishable from background. Ambient dose levels surrounding the vault with the designed shielding blocks in place are all within allowable limits for occupational workers. Conclusions: We have designed and installed a unique testing port for radiation protection and shielding measurements. This port is appropriately interlocked and designed to mitigate any risks of incidental exposure to staff or members of the public. The test port design allows measurements with “good geometry” and efficient removal of contaminating sources of radiation present in many shielding measurements. Daniel Harrell and Jim Noller are employees of Shielding Construction Solutions, Inc, the shielding construction company that built the vault discussed in this abstract. Manjit Chopra is an employee of Universal Minerals International, Inc, the company that provided the aggregates for the high density concretes used in the vault construction.

07 ISOTOPE AND RADIATION SOURCES↗

Re‐establishing the paradigm for evaluating halide salt compatibility to study commercial chloride salts at 600°C–800°C

Abstract Chloride salts are one candidate for a >700°C concentrating solar power (CSP) cycle, however, many reports from the literature suggest very high reaction rates between chloride salts and structural alloys. Historically, a specific methodology was established for evaluating halide salt compatibility based on solution kinetics. This study returned to that paradigm where the salts are purified and evaluated in sealed capsules before moving to a flowing experiment to determine a true corrosion rate in a temperature gradient for a commercial K–Mg–Na chloride salt. Isothermal testing focused on Ni‐based alloys 230 and 600 at 600°C–800°C. The results indicated there were promising combinations of salt chemistry, temperature, and alloy composition that reduce the extent of reaction. The results of the first monometallic thermal convection loop of alloy 600 run for 1,000 hr with a peak temperature of 700°C showed low attack with rates ≤9 µm/yr.

Pint, Bruce A.↗

Final Report for Closing the Loop Between In Situ Stress Complexity and EGS Fracture Complexity

Characterizing in situ stress is essential in Enhanced Geothermal System (EGS) for both risk assessment and operation design. Standard stress measurement techniques such as diagnostic fracture injection tests (DFITs) require creating hydraulic fractures and apply analytical methods such as the G -function analysis to estimate the stress. These classical approaches rely on several assumptions, including but not limited to: (i) the induced fracture is planar and persistent, and (ii) the fracture plane is normal to the minimum horizontal stress. However, these assumptions may not hold in EGS environments like Utah FORGE, where thermo-hydro-mechanical (THM) coupling, wellbore deviation, and rock heterogeneity can alter the local stress condition and consequently lead to fracture complexities in both near-well and far-field regions.

15 GEOTHERMAL ENERGY↗

An Advanced Platform for Development and Evaluation of Photovoltaic Inverters Using Hardware-in-the-Loop

A rapid shift in the world's energy paradigm towards a higher proliferation of renewables is underway. As these new resources are interconnected with the EPS, it is essential that they not only comply with the relevant interconnection standards, but that they also are evaluated under various dynamic resource input and grid conditions to ensure that they will properly participate in the advancedEPS architecture. To this end, NREL leveraged controller hardware-in-the-loop (CHIL) and power hardware-in-the-lopp (PHIL) simulation techniques to create an advanced platform for the development and evaluation of photovoltaic (PV) inverters. This paper describes a CHIL-based methodology by which PV inverter controllers can be tested against simulated inverter hardware before prior to at powertesting, a PHIL-based PV simulator that can be used to test a PV inverter's response to the truly dynamic output of a PV array, and a grid interconnection evaluator that leverages PHIL techniques to automate the execution and analysis of key interconnection standard test procedures. A number of demonstration test results are presented. These capabilities make up a novel platform that will helpdevelop the PV inverters that will support the next generation EPS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anatomy of the amplituhedron

We initiate a comprehensive investigation of the geometry of the amplituhedron, a recently found geometric object whose volume calculates the integrand of scattering amplitudes in planar \( \mathcal{N}=4 \) SYM theory. We do so by introducing and studying its stratification, focusing on four-point amplitudes. The new stratification exhibits interesting combinatorial properties and positivity is neatly captured by permutations. As explicit examples, we find all boundaries for the two and three loop amplitudes and related geometries. We recover the stratifications of some of these geometries from the singularities of the corresponding integrands, providing a non-trivial test of the amplituhedron/scattering amplitude correspondence. We finally introduce a deformation of the stratification with remarkably simple topological properties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Classical gravitational scattering at $\mathcal{O}(G^3)$ from Feynman diagrams

We perform a Feynman diagram calculation of the two-loop scattering amplitude for gravitationally interacting massive particles in the classical limit. Conveniently, we are able to sidestep the most taxing diagrams by exploiting the test-particle limit in which the system is fully characterized by a particle propagating in a Schwarzschild spacetime. We assume a general choice of graviton field basis and gauge fixing that contains as a subset the well-known deDonder gauge and its various cousins. As a highly nontrivial consistency check, all gauge parameters evaporate from the final answer. Moreover, our result exactly matches that of Bern et al., here verified up to sixth post-Newtonian order while also reproducing the same unique velocity resummation at third post-Minkowksian order.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compatibility of Alumina-Forming Austenitic Steels in Static and Flowing Pb

Alumina-forming austenitic (AFA) steels were evaluated for the lead fast reactor application in static and flowing high-purity Pb. Two AFA composition ranges with different Ni, Mn, Al, Cr and Nb contents were targeted, and Zr foil was used in an attempt to getter O in some capsules. Based on two rounds of capsule testing at 500–800°C, two AFA compositions were selected for evaluation in flowing Pb with a peak temperature of 650°C in a thermal convection loop made of pre-oxidized FeCrAlMo tubing. After exposure for 1000 h, the mass losses for both AFA alloys were generally low, suggesting good compatibility under these conditions without preoxidation.

36 MATERIALS SCIENCE↗

Improvement of transport-corrected scattering stability and performance using a Jacobi inscatter algorithm for 2D-MOC

The MPACT code, being developed collaboratively by the University of Michigan and Oak Ridge National Laboratory, is the primary deterministic neutron transport solver being deployed within the Virtual Environment for Reactor Applications (VERA) as part of the Consortium for Advanced Simulation of Light Water Reactors (CASL). In many applications of the MPACT code, transport-corrected scattering has proven to be an obstacle in terms of stability, and considerable effort has been made to try to resolve the convergence issues that arise from it. Most of the convergence problems seem related to the transport-corrected cross sections, particularly when used in the 2D method of characteristics (MOC) solver, which is the focus of this work. Here in this paper, the stability and performance of the 2-D MOC solver in MPACT is evaluated for two iteration schemes: Gauss-Seidel and Jacobi. With the Gauss-Seidel approach, as the MOC solver loops over groups, it uses the flux solution from the previous group to construct the inscatter source for the next group. Alternatively, the Jacobi approach uses only the fluxes from the previous outer iteration to determine the inscatter source for each group. Consequently for the Jacobi iteration, the loop over groups can be moved from the outermost loop$-$as is the case with the Gauss-Seidel sweeper$-$to the innermost loop, allowing for a substantial increase in efficiency by minimizing the overhead of retrieving segment, region, and surface index information from the ray tracing data. Several test problems are assessed: (1) Babcock & Wilcox 1810 Core I, (2) Dimple S01A-Sq, (3) VERA Progression Problem 5a, and (4) VERA Problem 2a. The Jacobi iteration exhibits better stability than Gauss-Seidel, allowing for converged solutions to be obtained over a much wider range of iteration control parameters. Additionally, the MOC solve time with the Jacobi approach is roughly 2.0-2.5× faster per sweep. While the performance and stability of the Jacobi iteration are substantially improved compared to the Gauss-Seidel iteration, it does yield a roughly 8$-$10% increase in the overall memory requirement.

97 MATHEMATICS AND COMPUTING↗

Localized Corrosion Behavior of Non-Equiatomic NiFeCrMnCo Multi-Principal Element Alloys

A series of single phase Ni 38 Fe 20 Cr x Mn 21–0.5x Co 21–0.5x multi-principal element alloys (MPEAs) were fabricated and their localized corrosion behavior was tested in 0.6 M NaCl solution. These MPEAs were found to be susceptible to localized corrosion, exhibiting pitting at room temperature, as indicated by positive hysteresis loops and low repassivation potentials observed in cyclic potentiodynamic polarization experiments. The pitting resistance increased with increasing Cr content. Interestingly, even the MPEAs with low chromium content, Ni 38 Fe 20 Cr 6 Mn 18 Co 18 and Ni 38 Fe 20 Cr 10 Mn 16 Co 16 , exhibited passivity and localized corrosion. Here, the passivity observed in these low chromium MPEAs is likely derived from their relatively high nickel content. Crystallographic pit morphology was observed in most of these MPEAs, suggesting the absence of a salt film on the dissolving pit surface. Such crystallographic pit morphology indicates that the pit growth in most of these MPEAs was under charge-transfer/ohmic control.

36 MATERIALS SCIENCE↗

ON THE MECHANISM OF HARD X-RAY EMISSION FROM MAGNETARS

Persistent activity of magnetars is associated with electric discharge that continually injects relativistic particles into the magnetosphere. Large active magnetic loops around magnetars must be filled with outflowing particles that interact with radiation via resonant scattering and spawn electron-positron pairs. The outflow energy is processed into copious e {sup {+-}} until the plasma enters outer parts of the loop where the magnetic field is reduced below 10{sup 13} G. In the outer zone, photons scattered by the outflow do not convert to e {sup {+-}} pairs and the outflow radiates its energy away. The escaping radiation forms a distinct hard X-ray peak in the magnetar spectrum. It has the following features: (1) its luminosity L = 10{sup 35}-10{sup 36} erg s{sup -1} can easily exceed the thermal luminosity from the magnetar surface, (2) its spectrum extends from 10 keV to the MeV band with a hard spectral slope, which depends on the object inclination to the line of sight, (3) the anisotropic hard X-ray emission exhibits strong pulsations as the magnetar spins, (4) the emission spectrum typically peaks around 1 MeV, but the peak position significantly oscillates with the spin period, (5) the emission is dominated by the extraordinary polarization mode at photon energies below {approx}1 MeV, and (6) the decelerated pairs accumulate and annihilate at the top of the magnetic loop, and emit the 511 keV line with luminosity L {sub ann} {approx} 0.1 L. Features (1)-(3) agree with available data; (4)-(6) can be tested by future observations.

79 ASTRONOMY AND ASTROPHYSICS↗