Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Multiband selection with linear array detectors

Several techniques that can be used in an earth-imaging system to separate the linear image formed after the collecting optics into the desired spectral band are examined. The advantages and disadvantages of the Multispectral Linear Array (MLA) multiple optics, the MLA adjacent arrays, the imaging spectrometer, and the MLA beam splitter are discussed. The beam-splitter design approach utilizes, in addition to relatively broad spectral region separation, a movable Multiband Selection Device (MSD), placed between the exit ports of the beam splitter and a linear array detector, permitting many bands to be selected. The successful development and test of the MSD is described. The device demonstrated the capacity to provide a wide field of view, visible-to-near IR/short-wave IR and thermal IR capability, and a multiplicity of spectral bands and polarization measuring means, as well as a reasonable size and weight at minimal cost and risk compared to a spectrometer design approach.

Richard, H. L.↗

Effect of high-energy electron irradiation in an electron microscope column on fluorides of alkaline earth elements (CaF{sub 2}, SrF{sub 2}, and BaF{sub 2})

The effect of high-energy (150 eV) electron irradiation in an electron microscope column on crystals of fluorides of alkaline earth elements CaF{sub 2}, SrF{sub 2}, and BaF{sub 2} is studied. During structural investigations by electron diffraction and electron microscopy, the electron irradiation causes chemical changes in MF{sub 2} crystals such as the desorption of fluorine and the accumulation of oxygen in the irradiated area with the formation of oxide MO. The fluorine desorption rate increases significantly when the electron-beam density exceeds the threshold value of {approx}2 Multiplication-Sign 10{sup 3} pA/cm{sup 2}). In BaF{sub 2} samples, the transformation of BaO into Ba(OH){sub 2} was observed when irradiation stopped. The renewal of irradiation is accompanied by the inverse transformation of Ba(OH){sub 2} into BaO. In the initial stage of irradiation of all MF{sub 2} compounds, the oxide phase is in the single-crystal state with a lattice highly matched with the MF{sub 2} matrix. When the irradiation dose is increased, the oxide phase passes to the polycrystalline phase. Gaseous products of MF{sub 2} destruction (in the form of bubbles several nanometers in diameter) form a rectangular array with a period of {approx}20 nm in the sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status and Prospects of Di-jet Production in High-energy Polarized Proton-Proton Collisions at RHIC at {radical}(s) = 200 GeV

The STAR experiment at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL) is carrying out a spin physics program colliding transversely or longitudinally polarized proton beams at {radical}(s) = 200-500 GeV to gain deeper insight into the spin structure and dynamics of the proton. These studies provide fundamental insight into Quantum Chromodynamics (QCD). One of the main objectives is the determination of the polarized gluon distribution function, {delta}g, through the measurement of the longitudinal double-spin asymmetry, A{sub LL}, for various processes. Inclusive hadron and jet production from polarized pp collision data collected so far at {radical}(s) = 200 GeV using the STAR detector at RHIC have placed important constraints on {delta}g. Di-jet production provides direct access to the initial parton kinematics at leading order (LO) QCD and thus provides sensitivity to the Bjorken-x dependence of {delta}g. The status of the mid-rapidity di-jet cross section analysis from the 2005 RHIC run and the longitudinal double-spin asymmetry at mid-rapidity for the 2006 data sample are discussed in these proceedings. Projections on future di-jet measurements at STAR are provided.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-70: Evaluation of Multiple Isocentric Intensity Modulated and Volumetric Modulated Arc Therapy Techniques Using Portal Dosimetry

Purpose: To develop a method for verification of dose distribution in a patient during treatment using multiple isocentric Intensity modulated and volumetric modulated arc therapy techniques with portal dosimetry. Methods: Varian True Beam accelerator, equipped with an aS1000 megavoltage electronic portal imaging device (EPID) has an integrated image mode for portal dosimetry (PD). The source-to-imager distance was taken at 150 cm to avoid collision to the table. Fourteen fractions were analyzed for this study. During shift in a single plan from one isocenter to another isocenter, EPID also shifted longitudinally for each field by taking the extent of divergence of beam into the consideration for EPID distance of 150cm. Patients were given treatment everyday with EPID placed in proper position for each field. Several parameters were obtained by comparing the dose distribution between fractions to fraction. The impact of the intra-fraction and inter-fraction of the patient in combination with isocenter shift of the beams were observed. Results: During treatment, measurements were performed by EPID and were evaluated by the gamma method. Analysis was done between fractions for multiple isocenter treatments. The pass rates of the gamma analysis with a criterion of 3% and 3 mm for the 14 fractions were over 97.8% with good consistency. Whereas maximum gamma exceeded the criteria in few fractions (in<1 cc vol). Average gamma was observed in the criteria of 0.5%. Maximum dose difference and average dose differences were less than 0.22 CU and 0.01 CU for maximum tolerance of 1.0 CU and 0.2 CU respectively. Conclusion: EPID with extended distance is ideal method to verify the multiple isocentric dose distribution in patient during treatment, especially cold and hot spots in junction dose. Verification of shifts as well as the dose differences between each fraction due to inter-fraction and intra-fraction of the patient can be derived.

60 APPLIED LIFE SCIENCES↗

Nisar L-band Digital Electronics Subsystem

The NASA-ISRO Synthetic Aperture Radar (NISAR) L-band SAR instrument employs multiple digital channels to optimize resolution while keeping a large swath on a single pass. High-speed digitization with fine synchronization and digital beam forming are necessary in order to facilitate this new technique called SweepSAR. An architecture employing multiple FPGA based digital signal processors has been conceived to facilitate digital calibration on an individual channel basis as well as digital signal processing to optimize the receive signal. On-board processing and data compression has been implemented to reduce the volume of data in order to satisfy the operational requirements of near global coverage for the desired science targets. A novel command and timing architecture was developed to manage this complex system to meet the challenging project requirements. The NISAR L-band Digital Electronics Subsystem is the combination of the hardware, firmware and software components architected and implemented to operate this radar and return the desired quantity and quality of data for the science community.

SweepSAR↗

Investigation of neutron-deuteron charge-exchange reaction at small transfer momentum

Analysis of the nd {sup {yields}} p(nn) reaction in the GeV energy region is performed in the framework based on the multiple-scattering theory for a few-nucleon system. The special kinematic condition where momentum transfer from neutron beam to final proton is close to zero is considered. The possibility of extracting the spin-dependent term of the elementary np {sup {yields}} pn amplitude from the nd breakup process is investigated. The energy dependence of the ratio R = {sigma}(R = frac d{sigma}{sub nd}) d {omega} and frac d{sigma}{sub np}) d{omega}) is obtained taking account of the final state interaction of the two outgoing neutrons in the {sup 1}S{sub 0} state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Investigation of neutron-deuteron charge-exchange reaction at small transfer momentum

Analysis of the nd {yields} p(nn) reaction in the GeV energy region is performed in the framework based on the multiple-scattering theory for a few-nucleon system. The special kinematic condition where momentum transfer from neutron beam to final proton is close to zero is considered. The possibility of extracting the spin-dependent term of the elementary np {yields} pn amplitude from the nd breakup process is investigated. The energy dependence of the ratio R = R = (d{sigma}{sub nd})/d{Omega} / (d{sigma}{sub np})/d{Omega} is obtained taking account of the finalstate interaction of the two outgoing neutrons in the {sup 1}S{sub 0} state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spin-manipulating polarized deuterons

Spin dynamics of polarized deuteron beams near depolarization resonances, including a new polarization preservation concept based on specially-designed multiple resonance crossings, has been tested in a series of experiments in the COSY synchrotron. Intricate spin dynamics with sophisticated pre-programmed patterns as well as effects of multiple crossings of a resonance were studied both theoretically and experimentally with excellent agreement. Possible applications of these results to preserve, manipulate and spin-flip polarized beams in synchrotrons and storage rings are discussed.

43 PARTICLE ACCELERATORS↗

Design of and data reduction from compact Thomson parabola spectrometers

Thomson parabola spectrometers are used to characterize MeV ion beams produced in high intensity laser interactions. These spectrometers disperse multiple ion species according to their charge to mass ratio through the use of parallel electric and magnetic fields. Analytical solutions for ion deflection in electric and magnetic fields have been used to extract ion spectra with the assumption that fringing effects are negligible. Experimental space restrictions and dynamic range requirements necessitate designs that stress the analytical assumptions. Depending on design parameters, the error in the analytical assumption can be comparable to the energy resolution. Estimates are provided to approximate the error on the total ion deflection. A method for modeling ion trajectories including fringing effects is presented using software freely available or in common use. The magnetostatic fields are modeled in 3D, including material properties of nearby magnetic materials using RADIA. Electrostatic fields are modeled in 2D for a spectrometer implementing angled plates using the partial differential equation toolbox in MATLAB. Using these models to calculate the ion trajectory allows for analysis of a Thomson parabola spectrometer with an arbitrary field configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Galactic Cosmic Ray Event-Based Risk Model (GERM) Code

This software describes the transport and energy deposition of the passage of galactic cosmic rays in astronaut tissues during space travel, or heavy ion beams in patients in cancer therapy. Space radiation risk is a probability distribution, and time-dependent biological events must be accounted for physical description of space radiation transport in tissues and cells. A stochastic model can calculate the probability density directly without unverified assumptions about shape of probability density function. The prior art of transport codes calculates the average flux and dose of particles behind spacecraft and tissue shielding. Because of the signaling times for activation and relaxation in the cell and tissue, transport code must describe temporal and microspatial density of functions to correlate DNA and oxidative damage with non-targeted effects of signals, bystander, etc. These are absolutely ignored or impossible in the prior art. The GERM code provides scientists data interpretation of experiments; modeling of beam line, shielding of target samples, and sample holders; and estimation of basic physical and biological outputs of their experiments. For mono-energetic ion beams, basic physical and biological properties are calculated for a selected ion type, such as kinetic energy, mass, charge number, absorbed dose, or fluence. Evaluated quantities are linear energy transfer (LET), range (R), absorption and fragmentation cross-sections, and the probability of nuclear interactions after 1 or 5 cm of water equivalent material. In addition, a set of biophysical properties is evaluated, such as the Poisson distribution for a specified cellular area, cell survival curves, and DNA damage yields per cell. Also, the GERM code calculates the radiation transport of the beam line for either a fixed number of user-specified depths or at multiple positions along the Bragg curve of the particle in a selected material. The GERM code makes the numerical estimates of basic physical and biophysical quantities of high-energy protons and heavy ions that have been studied at the NASA Space Radiation Laboratory (NSRL) for the purpose of simulating space radiation biological effects. In the first option, properties of monoenergetic beams are treated. In the second option, the transport of beams in different materials is treated. Similar biophysical properties as in the first option are evaluated for the primary ion and its secondary particles. Additional properties related to the nuclear fragmentation of the beam are evaluated. The GERM code is a computationally efficient Monte-Carlo heavy-ion-beam model. It includes accurate models of LET, range, residual energy, and straggling, and the quantum multiple scattering fragmentation (QMSGRG) nuclear database.

Cucinotta, Francis A.↗

Filamentation and Self-Focusing of Electron Beams in Vacuum and Gas Diodes

In this paper, we experimentally studied pulsed electron beams with a high local density. The conditions in which the energy density cumulation is observed during the interaction of electrons with the anode are shown to develop in vacuum and gas diodes at nanosecond and subnanosecond durations of a beam current pulse and a decrease in the interelectrode gap. The average electron energy in filamentation and self-focusing of an electron beam in a vacuum diode of an accelerator at a current of ~2 kA and a no-load voltage of ~400 kV was established to be 50–100 keV while the energy density was 10{sup 9}–10{sup 10} J/cm{sup 3}. It is confirmed that the beam current density in a gas diode can exceed 1 kA/cm{sup 2}. It is hypothesized that superdense electron beams in vacuum and gas diodes are formed as a result of avalanche multiplication of runaway electrons in the cathode–anode gap plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flattening Filter Free vs Flattened Beams for Breast Irradiation

Purpose: Flattening filter free (FFF) beams offer the potential for a higher dose rate, shorter treatment time, and lower peripheral dose. To investigate their role in large-field treatments, this study compared flattened and FFF beams for breast irradiation. Methods and Materials: Ten left breast clinical plans comprising 2 tangential beams and a medially located 3-field simultaneous integrated boost (SIB) were replanned. Full intensity modulated radiotherapy (IMRT), hybrid IMRT, electronic tissue compensator (ETC), and multiple static field treatment plans were created for the elective breast volume using flattened and FFF beams, in combination with a 3-field IMRT SIB. Plan quality was assessed and delivery times were measured for all plans for 1 patient. Out-of-field doses were measured using an ionization chamber for an IMRT plan optimized on a corner of simple cubic phantom for both flattened and FFF beams. Results: For each technique, mean target volume metrics (planning target volume coverage, homogeneity, conformity) were typically within 3% for flattened and FFF beams. Larger mean differences in boost conformity favoring flattened hybrid (7.2%) and full IMRT (5.5%) plans may have reflected limitations in plan normalization. Calculated heart and ipsilateral lung doses were comparable; however, both flattened and FFF low-dose phantom measurements were substantially higher than calculated values, rendering the comparison of low dose in the contralateral breast uncertain. Beam delivery times were on average 31% less for FFF. Conclusions: In general, target volume metrics for flattened and FFF plans were comparable. The planning system did not seem to allow for accurate peripheral dose evaluation. FFF was associated with a potentially shorter treatment time. All 4 IMRT techniques allowed FFF beams to generate acceptable plans for breast IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Simons Observatory: HoloSim-ML: machine learning applied to the efficient analysis of radio holography measurements of complex optical systems

Near-field radio holography is a common method for measuring and aligning mirror surfaces for millimeter and sub-millimeter telescopes. In instruments with more than a single mirror, degeneracies arise in the holography measurement, requiring multiple measurements and new fitting methods. We present HoloSim-ML, a Python code for beam simulation and analysis of radio holography data from complex optical systems. This code uses machine learning to efficiently determine the position of hundreds of mirror adjusters on multiple mirrors with few micron accuracy. We apply this approach to the example of the Simons Observatory 6m telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An alpha particle measurement system using an energetic neutral helium beam in ITER (invited)

An energetic helium neutral beam is involved in the beam neutralization measurement system of alpha particles confined in a DT fusion plasma. A full size strong-focusing He{sup +} ion source (2 A, the beam radius of 11.3 mm, the beam energy less than 20 keV). Present strong-focusing He{sup +} ion source shows an emittance diagram separated for each beamlet of multiple apertures without phase space mixing, despite the space charge of a beamlet is asymmetric and the beam flow is non-laminar. The emittance of beamlets in the peripheral region was larger than that of center. The heat load to the plasma electrode was studied to estimate the duty factor for the ITER application.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of optical crystals and quasicrystal beams: Kaleidoscopic patterns and phase singularity

We explore the feasibility of the generation of pseudonondiffracting optical beams related to crystal and quasicrystal structures. It is experimentally confirmed that optical crystal and quasicrystal beams can be remarkably generated with a collimated light to illuminate a high-precision mask with multiple apertures regularly distributed on a ring. We also found that exotic kaleidoscopic patterns can be exhibited with the high-order quasicrystal beams. More importantly, the structures of phase singularities in optical quasicrystal beams are manifested.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DESDynI Quad First Stage Processor - A Four Channel Digitizer and Digital Beam Forming Processor

The proposed Deformation, Eco-Systems, and Dynamics of Ice Radar (DESDynI-R) L-band SAR instrument employs multiple digital channels to optimize resolution while keeping a large swath on a single pass. High-speed digitization with very fine synchronization and digital beam forming are necessary in order to facilitate this new technique. The Quad First Stage Processor (qFSP) was developed to achieve both the processing performance as well as the digitizing fidelity in order to accomplish this sweeping SAR technique. The qFSP utilizes high precision and high-speed analog to digital converters (ADCs), each with a finely adjustable clock distribution network to digitize the channels at the fidelity necessary to allow for digital beam forming. The Xilinx produced FX130T Virtex 5 part handles the processing to digitally calibrate each channel as well as filter and beam form the receive signals. Demonstrating the digital processing required for digital beam forming and digital calibration is instrumental to the viability of the proposed DESDynI instrument. The qFSP development brings this implementation to Technology Readiness Level (TRL) 6. This paper will detail the design and development of the prototype qFSP as well as the preliminary results from hardware tests.

Chuang, Chung-Lun↗

3D Dose Reconstruction to Insure Correct External Beam Treatment of Patients

Radiation therapy treatments have become increasingly more complicated. There are multiple opportunities for humans, machines, software, and combinations thereof to result in a treatment error that could be of significance. Current methods for quality assurance are often abstract in nature and may have unclear underlying assumptions as to what is assumed to be working correctly, or may depend upon the diligence of persons to discover errors from a review of the treatment plan. Here, an example will be shown of a direct method to reconstruct and demonstrate the dose and the dose distribution delivered to a particular patient. By measuring the radiation fields that come out of the accelerator, and using the measurement as input to a 3-dimensional (3D) dose algorithm, the delivered patient dose is determined and presented in a manner similar to the treatment plan. The intended treatment plan dose may be directly compared. Using this feedback mechanism, there is less abstraction and dependence upon the diligence of individuals checking multiple steps in a treatment process, and assumptions can be clearly stated. With this system, the dose is determined and presented minimizing assumptions and dependence upon other systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Near L-edge Single and Multiple Photoionization of Doubly Charged Iron Ions

Using the photon-ion merged-beams technique at a synchrotron light source, we have measured relative cross sections for single and up to five-fold photoionization of Fe 2+ ions in the energy range of 690-920 eV. This range contains thresholds and resonances associated with ionization and excitation of 2p and 2s electrons. Calculations were performed to simulate the total absorption spectra. The theoretical results show very good agreement with the experimental data, if overall energy shifts of up to 2.5 eV are applied to the calculated resonance positions and assumptions are made about the initial experimental population of the various levels of the Fe 2+ ([Ar]3d 6 ) ground configuration. Furthermore, we performed extensive calculations of the Auger cascades that result when an electron is removed from the 2p subshell of Fe 2+ . These computations lead to a better agreement with the measured product-charge-state distributions as compared to earlier work. We conclude that the L-shell absorption features of low-charged iron ions are useful for identifying gas-phase iron in the interstellar medium and for discriminating against the various forms of condensed-phase iron bound to composite interstellar dust grains.

79 ASTRONOMY AND ASTROPHYSICS↗