Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

A real-time optical data processing device

The design, operation, and structure of the hybrid field effect light valve, a real-time input device for application to coherent optical data processing (CODP), is described. The device consists of a sandwich of thin films that electrically control the optical birefringence of a thin (2 micrometer) liquid crystal layer. It has high resolution (greater than 100 1/mm), contrast ratio (greater than 100:1), speed (10 sec on, 15 sec off) and input sensitivity (about 0.3 ergs/sq cm) in addition to cost and size advantages. Performance data for a laboratory model are presented.

Jacobson, A.↗

Evaluation Program for Secondary Spacecraft Cells: Synchronous Orbit Testing of Sealed Nickel Cadmium Cells

Performance data concerning sealed nickel-cadmium cells operating under a synchronous orbit regime are presented. A space satellite maintaining a position over a fixed point on earth as the earth rotates on its axis and revolves about the sun was simulated. Results include: (1) exposure to synchronous orbit testing at a temperature of 40 C yields less than 6 years of life; (2) performance at -20 C presents a low capacity problem; (3) the capacity check, performed at the middle of each show period, provides a temporary red reconditioning effect on the cells in that the end-of-discharge voltages are higher, for approximately 7 to 10 days, following the capacity check than they were 7 to 10 days prior to the capacity check; (4) all the test packs at -20 C and 40 C have either failed or were discontinued because of low capacity; and (5) test packs at temperatures of 0 C and 10 C have delivered the best capacity during life and packs tested at 20 C showed better life capability than packs tested at -20 C and 40 C.

Harkness, J. D.↗

Initial Closed Operation of the CELSS Test Facility Engineering Development Unit

As part of the NASA Controlled Ecological Life Support System (CELSS) Program, a CELSS Test Facility (CTF) is being planned for installation on the Space Station. The CTF will be used to provide data on the productivity and efficiency of a variety of CELSS higher plant crops grown sequentially from seed to harvest in the microgravity environment of the Space Station. Stringent environmental control will be maintained while fundamental crop productivity issues, such as carbon dioxide uptake and oxygen production rates, water transpiration rates, and biomass accumulation rates are obtained for comparison with ground-based data. In order to obtain an early realistic determination of the subsystem and system requirements necessary to provide the appropriate environmental conditions specified for CTF crop productivity experiments, an Engineering Development Unit (EDU) has been constructed and is undergoing initial operational testing at NASA Ames Research Center. The EDU is a ground-based testbed which will be used to characterize the integrated performance of major subsystem technologies, to evaluate hardware candidates and control strategies required for the CTF, and to further define the ability to meet CTF requirements within present Space Station constraints. This paper describes the initial closed operational testing of the EDU. Measured performance data are compared with the specified functional requirements and results from initial closed testing are presented. Plans for future science and technology testing are discussed.

Kliss, Mark↗

Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant

Membrane-based Liquid Desiccant Air Dehumidifier (MLDAD) has the potential to overcome the shortcomings of the conventional open-tower liquid desiccant air dehumidifier. The MLDAD uses membranes with high water vapor permeability to separate air stream from the liquid desiccant and thus eliminates carry-over and the resulting corrosion issues. Recently, the ionic liquid desiccant becomes a promising alternative to conventional liquid desiccant. The ionic liquid desiccant has a large potential of dehumidification, which is also non-corrosive to metals and non-crystallizable. A two-dimensional numerical heat and mass transfer model of the MLDAD using a recently identified ionic liquid desiccant, [EMIM]OAc, is presented in this paper. We report this model can simulate the performance of the MLDAD with various designs, including different selections of liquid desiccant and membrane materials, dimensions of the MLDAD, and flow patterns. For porous membranes, this model accounts for several micro-scale mass transfer mechanisms of vapor transportation across the membrane. It can also model the mass transfer performance of dehumidifiers using non-porous membranes based on the experimentally measured membrane permeance. The numerical model was validated against the performance data available from literature and experimental tests. The maximum discrepancy of the latent effectiveness between the measured and the model-predicted results was about 6% when porous membranes were used. A parametric study was conducted with the numerical model. The results indicated that the membrane permeability, air path height, and solution to air mass ratio were the most critical parameters, determining the dehumidification performance of the MLDAD.

42 ENGINEERING↗

Investigating the impact of a multi-module operation environment on the task performance time of human operators – An explanatory study

The worldwide demand for Small Modular Reactors (SMRs) has surged in recent years due to their enhanced safety and versatility in supporting diverse industrial sectors. A unique feature of SMR operation is that a single human operator is responsible for managing multiple modules. Therefore, securing a sufficient amount of human performance data pertaining to this new environment is essential for the safe operation of SMRs. In this explanatory study, a series of experiments were conducted using the NuScale simulator, a representative SMR design, with student operators. A total of 12 student operators were assigned two types of off-normal events and asked to cope with them using paper-based procedures. Subsequently, their task performance times were compared with those of student operators responsible for a single unit based on the Task Complexity (TACOM) measure. Results indicate that the performance of student operators under the experimental conditions of this study degraded by a factor of 2 to 3, depending on the characteristics of the off-normal events.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bringing the Heat: Thermal Protection Systems for Low Earth Orbit Transportation and Lunar Exploration

Thermal protection systems (TPS) protect spacecraft from the heating associated with hypersonic flight through a planet’s atmosphere. The materials are subjected to extreme heating and the overall system must be engineered to reliably protect the spacecraft structure during atmospheric entry. The talk will introduce TPS and describe three NASA-led efforts to develop TPS materials and manufacturing processes. The first effort studied thermally stable ceramic aerogels for use in thermal barriers and high temperature seals. A design framework for such materials is proposed, linking the thermal stability performance data with existing material property measurements. The second project, Additive Manufacturing of Thermal Protection Systems (AMTPS), developed an automated, additive approach for ablative heat shield manufacturing. Novel material systems and manufacturing methods were developed to reduce the time required to manufacture ablative TPS heat shields. The third effort tackles a critical challenge of material obsolescence for silica fiber based reusable TPS. The properties and performance of heritage silica fiber are quantified and compared to modern alternatives to support qualification for flight. The talk will also describe other work in TPS conducted by the Thermal Design Branch at NASA JSC and opportunities for students and faculty to get involved with NASA.

Nathaniel Olson↗

Electrical signature analysis to quantify human and animal performance on fitness and therapy equipment such as a treadmill

The invention is a human and animal performance data acquisition, analysis, and diagnostic system for fitness and therapy devices having an interface box removably disposed on incoming power wiring to a fitness and therapy device, at least one current transducer removably disposed on said interface box for sensing current signals to said fitness and therapy device, and a means for analyzing, displaying, and reporting said current signals to determine human and animal performance on said device using measurable parameters.

47 OTHER INSTRUMENTATION↗

Electrical signal analysis to assess the physical condition of a human or animal

The invention is a human and animal performance data acquisition, analysis, and diagnostic system for fitness and therapy devices having an interface box removably disposed on incoming power wiring to a fitness and therapy device, at least one current transducer removably disposed on said interface box for sensing current signals to said fitness and therapy device, and a means for analyzing, displaying, and reporting said current signals to determine human and animal performance on said device using measurable parameters.

47 OTHER INSTRUMENTATION↗

Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced

A Model Predictive Control algorithm was developed for the UC Merced campus chilled water plant. Model predictive control (MPC) is an advanced control technology that has proven successful in the chemical process industry and other industries. The main goal of the research was to demonstrate the practical and commercial viability of MPC for optimization of building energy systems. The control algorithms were developed and implemented in MATLAB, allowing for rapid development, performance, and robustness assessment. The UC Merced chilled water plant includes three water-cooled chillers and a two million gallon chilled water storage tank. The tank is charged during the night to minimize on-peak electricity consumption and take advantage of the lower ambient wet bulb temperature. The control algorithms determined the optimal chilled water plant operation including chilled water supply (CHWS) temperature set-point, condenser water supply (CWS) temperature set-point and the charging start and stop times to minimize a cost function that includes energy consumption and peak electrical demand over a 3-day prediction horizon. A detailed model of the chilled water plant and simplified models of the buildings served by the plant were developed using the equation-based modeling language Modelica. Steady state models of the chillers, cooling towers and pumps were developed, based on manufacturers performance data, and calibrated using measured data collected and archived by the control system. A detailed dynamic model of the chilled water storage tank was also developed and calibrated. Simple, semi-empirical models were developed to predict the temperature and flow rate of the chilled water returning to the plant from the buildings. These models were then combined and simplified for use in a model predictive control algorithm that determines the optimal chiller start and stop times and set-points for the condenser water temperature and the chilled water supply temperature. The report describes the development and testing of the algorithm and evaluates the resulting performance, concluding with a discussion of next steps in further research. The experimental results show a small improvement in COP over the baseline policy but it is difficult to draw any strong conclusions about the energy savings potential for MPC with this system only four days of suitable experimental data were obtained once correct operation of the MPC system had been achieved. These data show an improvement in COP of 3.1% {+-} 2.2% relative to a baseline established immediately prior to the period when the MPC was run in its final form. This baseline includes control policy improvements that the plant operators learned by observing the earlier implementations of MPC, including increasing the temperature of the water supplied to the chiller condensers from the cooling towers. The process of data collection and model development, necessary for any MPC project, resulted in the team uncovering various problems with the chilled water system. Although it is difficult to quantify the energy savings resulting from these problems being remedied, they were likely on the same order as the energy savings from the MPC itself. Although the types of problems uncovered and the level of energy savings may differ significantly from other projects, some of the benefits of detecting and diagnosing problems are expected from the use of MPC for any chilled water plant. The degree of chiller loading was found to be a key factor for efficiency. It is more efficient to operate the chillers at or near full load. In order to maximize the chiller load, one would maximize the temperature difference across chillers and the chilled water flow rate through the chillers. Thus, the CHWS set-point and the chilled water flow-rate can be used to limit the chiller loading to prevent chiller surging. Since the flow rate has an upper bound and the CHWS set point has a lower bound, the chiller loading is constrained and often determined by the chilled water return temperature (CHWR). The CHWR temperature is primarily comprised of warm water from the top of the TES tank. The CHWR temperature falls substantially as the thermocline approaches the top of the tank, which reduces the chiller loading. As a result, it has been determined that overcharging the TES tank can be detrimental to the chilled water plant efficiency. The resulting MPC policy differs from the current practice of fully charging the TES tank. A heuristic rule could possible avoid this problem without using predictive control. Similarly, the COP improvements from the change in CWS set-point were largely captured by a static set-point change by the operators. Further research is required to determine how much of the MPC savings could be garnered through simplified rules (based on the MPC study), with and without prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant

Membrane-based Liquid Desiccant Air Dehumidifier (MLDAD) has the potential to overcome the shortcomings of the conventional open-tower liquid desiccant air dehumidifier. The MLDAD uses membranes with high water vapor permeability to separate air stream from the liquid desiccant and thus eliminates carry-over and the resulting corrosion issues. Recently, the ionic liquid desiccant becomes a promising alternative to conventional liquid desiccant. The ionic liquid desiccant has a large potential of dehumidification, which is also non-corrosive to metals and non-crystallizable. A two-dimensional numerical heat and mass transfer model of the MLDAD using a recently identified ionic liquid desiccant, [EMIM]OAc, is presented here. This model can simulate the performance of the MLDAD with various designs, including different selections of liquid desiccant and membrane materials, dimensions of the MLDAD, and flow patterns. For porous membranes, this model accounts for several micro-scale mass transfer mechanisms of vapor transportation across the membrane. It can also model the mass transfer performance of dehumidifiers using non-porous membranes based on the experimentally measured membrane permeance. The numerical model was validated against the performance data available from literature and experimental tests. The maximum discrepancy of the latent effectiveness between the measured and the model-predicted results was about 6% when porous membranes were used. A parametric study was conducted with the numerical model. Finally, the results indicated that the membrane permeability, air path height, and solution to air mass ratio were the most critical parameters, determining the dehumidification performance of the MLDAD.

42 ENGINEERING↗

Hover performance tests of full scale variable geometry rotors

Full scale whirl tests were conducted to determine the effects of interblade spatial relationships and pitch variations on the hover performance and acoustic signature of a 6-blade main rotor system. The variable geometry rotor (VGR) variations from the conventional baseline were accomplished by: (1) shifting the axial position of alternate blades by one chord-length to form two tip path planes; and (2) varying the relative azimuthal spacing from the upper rotor to the lagging hover rotor in four increments from 25.2 degrees to 62.1 degrees. For each of these four configurations, the differential collective pitch between upper and lower rotors was set at + or - 1 deg, 0 deg and -1 deg. Hover performance data for all configurations were acquired at blade tip Mach numbers of 0.523 and 0.45. Acoustic data were recorded at all test conditions, but analyzed only at 0 deg differential pitch at the higher rotor speed. The VGR configurations tested demonstrated improvements in thrust at constant power as high as 6 percent. Reductions of 3 PNdb in perceived noise level and of 4 db in blade passage frequency noise level were achieved at the higher thrust levels. Consistent correlation exists between performance and acoustic improvements. For any given azimuth spacing, performance was consistently better for the differential pitch condition of + or - 1 degree, i.e. with the upper rotor pitch one degree higher than the lower rotor.

Rorke, J. B.↗

Numerical Modeling of Heat Transfer and Flow in Low Power Arcjet Thruster

Modeling studies are preformed to investigate the plasma and heat transfer characteristics of a low power argon arcjet thruster. Computed temperature, velocity, static pressure, and Mach number distribution in arcjet thruster under typical operating condition are presented in this paper. It shows that the performance data from numerical modeling results are basically consistent with the experimental measured values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative Assessment of Direct Drive High Temperature Superconducting Generators in Multi-Megawatt Class Wind Turbines

This paper summarizes the work completed under the CRADA between NREL and American Superconductor (AMSC). The CRADA combined NREL and AMSC resources to benchmark high temperature superconducting direct drive (HTSDD) generator technology by integrating the technologies into a conceptual wind turbine design, and comparing the design to geared drive and permanent magnet direct drive (PMDD) windturbine configurations. Analysis was accomplished by upgrading the NREL Wind Turbine Design Cost and Scaling Model to represent geared and PMDD turbines at machine ratings up to 10 MW and then comparing cost and mass figures of AMSC's HTSDD wind turbine designs to theoretical geared and PMDD turbine designs at 3.1, 6, and 10 MW sizes. Based on the cost and performance data supplied by AMSC,HTSDD technology has good potential to compete successfully as an alternative technology to PMDD and geared technology turbines in the multi megawatt classes. In addition, data suggests the economics of HTSDD turbines improve with increasing size, although several uncertainties remain for all machines in the 6 to 10 MW class.

17 WIND ENERGY↗

Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit

The Advanced Stirling Radioisotope Generator (ASRG), a high efficiency generator, is being considered for space missions. An engineering unit, the ASRG engineering unit (EU), was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently under extended operation test at the NASA Glenn Research Center (GRC) to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for the ASRG EU. This paper summarizes details of the test facility design, including the mechanical mounting, heat-rejection system, argon system, control systems, and maintenance. The effort proceeded from requirements definition through design, analysis, build, and test. Initial testing and facility performance results are discussed.

Lewandowski, Edward J.↗

WTP Waste Feed Qualification: Hydrogen Generation Rate Measurement Apparatus Testing Report

The generation rate of hydrogen gas in the Hanford tank waste will be measured during the qualification of the staged tank waste for processing in the Hanford Tank Waste Treatment and Immobilization Plant. Based on a review of past practices in measurement of the hydrogen generation, an apparatus to perform this measurement has been designed and tested for use during waste feed qualification. The hydrogen generation rate measurement apparatus (HGRMA) described in this document utilized a 100 milliliter sample in a continuously-purged, continuously-stirred vessel, with measurement of hydrogen concentration in the vent gas. The vessel and lid had a combined 220 milliliters of headspace. The vent gas system included a small condenser to prevent excessive evaporative losses from the sample during the test, as well as a demister and filter to prevent particle migration from the sample to the gas chromatography system. The gas chromatograph was an on line automated instrument with a large-volume sample-injection system to allow measurement of very low hydrogen concentrations. This instrument automatically sampled the vent gas from the hydrogen generation rate measurement apparatus every five minutes and performed data regression in real time. The fabrication of the hydrogen generation rate measurement apparatus was in accordance with twenty three (23) design requirements documented in the conceptual design package, as well as seven (7) required developmental activities documented in the task plan associated with this work scope. The HGRMA was initially tested for proof of concept with physical simulants, and a remote demonstration of the system was performed in the Savannah River National Laboratory Shielded Cells Mockup Facility. Final verification testing was performed using non-radioactive simulants of the Hanford tank waste. Three different simulants were tested to bound the expected rheological properties expected during waste feed qualification testing. These simulants were tested at different temperatures using purge gas spiked with varying amounts of hydrogen to provide verification that the system could accurately measure the hydrogen in the vent gas at steady state.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanical Properties and Deformation Behavior of Additively Manufactured 316L Stainless Steel (FY2020)

The Transformational Challenge Reactor (TCR) program plans to build most of the TCR core components through additive manufacturing (AM) processes. These processes include laser powder bed fusion (LPBF) for the metallic (316L) components and the newly developed combined process of binderjet printing and chemical vapor infiltration (CVI) for the SiC fuel matrix. Mechanical testing and characterization tasks have been carried out since the beginning of the TCR program to (1) build a property database for the AM materials that will be used in TCR core and (2) to assess the materials’ performance in TCR-relevant conditions. This document reports the outcome of the testing and characterization efforts for the fiscal year with a focus on the mechanical performance data of AM 316L stainless steel (SS). Baseline tensile testing over a wide temperature range of room temperature–600 °C was completed for the AM 316L alloy in as-built, stress-relieved, and solution-annealed conditions. The as-built 316L showed the highest strength, and the alloy after the post-build treatments showed reduced strengths in the low-strain range. However, the strength differences among the AM materials became insignificant in the later part of deformation. Furthermore, regardless of post-build processing, the AM 316L SS showed higher strength and comparable ductility when compared with wrought 316L SS. Thermal creep testing and microstructural evolution during creep deformation were also performed under selected conditions. It was found that the AM 316L steel showed the best creep resistance in the stress-relieved condition. In-situ tensile tests were performed using scanning electron microscopy and 1-ID beamline at the Advanced Photon Source to elucidate the deformation and fracture behavior of AM 316L and the evolution of crystalline stress, dislocations, and pore distribution. Using these in-situ testing data, an in-depth analysis of the roles of microstructural features in deformation and fracture processes is presented herein. The final section of the document introduces ongoing and future activities for materials testing and characterization, including irradiation effect studies and ball punch testing on AM 316L and AM IN718 alloys.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

2016 Annual Technology Baseline

Current and future cost and performance data for electricity generating technologies, including both renewable and conventional technologies.

13 HYDRO ENERGY↗

X-ray driven implosions at ignition relevant velocities on the National Ignition Facility

Backlit convergent ablator experiments on the National Ignition Facility [E. I. Moses et al., Phys. Plasmas 16, 041006 (2009)] are indirect drive implosions that study the inflight dynamics of an imploding capsule. Side-on, backlit radiography provides data used by the National Ignition Campaign to measure time-dependent properties of the capsule ablator including its center of mass radius, velocity, and unablated mass. Previously, Callahan [D. A. Callahan et al., Phys. Plasmas 19, 056305 (2012)] and Hicks [D. H. Hicks et al., Phys. Plasmas 19, 122702 (2012)] reported backlit convergent ablator experiments demonstrating velocities approaching those required for ignition. This paper focuses on implosion performance data in the “rocket curve” plane, velocity vs. ablator mass. These rocket curve data, along with supporting numerical simulations, show that the nominal 195 μm-thick ignition capsule would reach the ignition velocity goal V = 370 km/s with low ablator mass remaining–below the goal of M = 0.25 mg. This finding led to experiments with thicker capsule ablators. A recent symmetry capsule experiment with a 20 μm thicker capsule driven by 520 TW, 1.86 MJ laser pulse (along with a companion backlit convergent ablator experiment) appears to have demonstrated V≥350 km/s with ablator mass remaining above the ignition goal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗